@@ -335,6 +335,28 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/
"CS5800iG",boiler,16,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1
"CS5800iG",boiler,16,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1
"CS5800iG",boiler,16,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1
"CS5800iG",boiler,16,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,5,0,1/10,244,1
"CS5800iG",boiler,16,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,5,0,1,245,1
"CS5800iG",boiler,16,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,5,0,1,246,1
"CS5800iG",boiler,16,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,5,0,1/10,247,1
"CS5800iG",boiler,16,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,5,0,1,248,1
"CS5800iG",boiler,16,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,5,0,1,249,1
"CS5800iG",boiler,16,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,5,0,1,250,1
"CS5800iG",boiler,16,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,5,0,1,251,1
"CS5800iG",boiler,16,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,5,0,1,252,1
"CS5800iG",boiler,16,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,5,0,1,253,1
"CS5800iG",boiler,16,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,5,0,1,254,1
"CS5800iG",boiler,16,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock,5,0,1/10,255,1
"CS5800iG",boiler,16,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,5,0,1,256,1
"CS5800iG",boiler,16,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,5,0,1,257,1
"CS5800iG",boiler,16,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,5,0,1,258,1
"CS5800iG",boiler,16,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,5,0,1,259,1
"CS5800iG",boiler,16,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,5,0,1,260,1
"CS5800iG",boiler,16,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,5,0,1,261,1
"CS5800iG",boiler,16,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,5,0,1,262,1
"CS5800iG",boiler,16,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,5,0,1,263,1
"CS5800iG",boiler,16,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,5,0,1,264,1
"CS5800iG",boiler,16,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,5,0,1,265,1
"CS5800iG",boiler,16,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1
"CS5800iG",boiler,16,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1
"CS5800iG",boiler,16,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1
@@ -365,131 +387,12 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/
"CS5800iG",boiler,16,pc1flow,Flow PC1,int16 (>=-31999<=31999),l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,5,0,1,80,1
"CS5800iG",boiler,16,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,5,0,1,81,1
"CS5800iG",boiler,16,pc1rate,PC1 rate,uint8 (>=0<=100),%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,5,0,1,82,1
"CS5800iG",boiler,16,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,83,2
"CS5800iG",boiler,16,dhw.nrg,energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_energy,sensor.boiler_dhw_nrg,5,9,1/100,0,2
"CS5800iG",boiler,16,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_energy_heating,sensor.boiler_nrgheat,5,0,1/100,85,2
"CS5800iG",boiler,16,nrgcool,energy cooling,uint24 (>=0<=167772),kWh,false,sensor.boiler_energy_cooling,sensor.boiler_nrgcool,5,0,1/100,87,2
"CS5800iG",boiler,16,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_total,sensor.boiler_metertotal,5,0,1/100,89,2
"CS5800iG",boiler,16,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_compressor,sensor.boiler_metercomp,5,0,1/100,91,2
"CS5800iG",boiler,16,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_e-heater,sensor.boiler_metereheat,5,0,1/100,93,2
"CS5800iG",boiler,16,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/100,95,2
"CS5800iG",boiler,16,metercool,meter cooling,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_cooling,sensor.boiler_metercool,5,0,1/100,97,2
"CS5800iG",boiler,16,dhw.meter,meter,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/100,2,2
"CS5800iG",boiler,16,uptimetotal,heatpump total uptime,time (>=0<=279620),minutes,false,sensor.boiler_heatpump_total_uptime,sensor.boiler_uptimetotal,5,0,1/60,99,2
"CS5800iG",boiler,16,uptimecontrol,total operating time heat,time (>=0<=279620),minutes,false,sensor.boiler_total_operating_time_heat,sensor.boiler_uptimecontrol,5,0,1/60,101,2
"CS5800iG",boiler,16,uptimecompheating,operating time compressor heating,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_heating,sensor.boiler_uptimecompheating,5,0,1/60,103,2
"CS5800iG",boiler,16,uptimecompcooling,operating time compressor cooling,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_cooling,sensor.boiler_uptimecompcooling,5,0,1/60,105,2
"CS5800iG",boiler,16,dhw.uptimecomp,operating time compressor,time (>=0<=279620),minutes,false,sensor.boiler_dhw_operating_time_compressor,sensor.boiler_dhw_uptimecomp,5,9,1/60,4,2
"CS5800iG",boiler,16,uptimecomppool,operating time compressor pool,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_pool,sensor.boiler_uptimecomppool,5,0,1/60,107,2
"CS5800iG",boiler,16,totalcompstarts,total compressor control starts,uint24 (>=0<=16777214), ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts,5,0,1,109,2
"CS5800iG",boiler,16,heatingstarts,heating control starts,uint24 (>=0<=16777214), ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts,5,0,1,111,2
"CS5800iG",boiler,16,coolingstarts,cooling control starts,uint24 (>=0<=16777214), ,false,sensor.boiler_cooling_control_starts,sensor.boiler_coolingstarts,5,0,1,113,2
"CS5800iG",boiler,16,dhw.startshp,starts hp,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts_hp,sensor.boiler_dhw_startshp,5,9,1,6,2
"CS5800iG",boiler,16,poolstarts,pool control starts,uint24 (>=0<=16777214), ,false,sensor.boiler_pool_control_starts,sensor.boiler_poolstarts,5,0,1,115,2
"CS5800iG",boiler,16,nrgconstotal,total energy consumption,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal,5,0,1,117,2
"CS5800iG",boiler,16,nrgconscomptotal,total energy consumption compressor,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal,5,0,1,119,2
"CS5800iG",boiler,16,nrgconscompheating,energy consumption compressor heating,uint24 (>=0<=16777214),kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating,5,0,1,121,2
"CS5800iG",boiler,16,dhw.nrgconscomp,energy consumption compressor,uint24 (>=0<=16777214),kWh,false,sensor.boiler_dhw_energy_consumption_compressor,sensor.boiler_dhw_nrgconscomp,5,9,1,8,2
"CS5800iG",boiler,16,nrgconscompcooling,energy consumption compressor cooling,uint24 (>=0<=16777214),kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling,5,0,1,123,2
"CS5800iG",boiler,16,nrgconscomppool,energy consumption compressor pool,uint24 (>=0<=16777214),kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool,5,0,1,125,2
"CS5800iG",boiler,16,auxelecheatnrgconstotal,total aux elec. heater energy consumption,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal,5,0,1,127,2
"CS5800iG",boiler,16,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,uint24 (>=0<=16777214),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating,5,0,1,129,2
"CS5800iG",boiler,16,dhw.auxelecheatnrgcons,aux elec. heater energy consumption,uint24 (>=0<=16777214),kWh,false,sensor.boiler_dhw_aux_elec._heater_energy_consumption,sensor.boiler_dhw_auxelecheatnrgcons,5,9,1,10,2
"CS5800iG",boiler,16,auxelecheatnrgconspool,aux elec. heater energy consumption pool,uint24 (>=0<=16777214),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool,5,0,1,131,2
"CS5800iG",boiler,16,nrgsupptotal,total energy supplied,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal,5,0,1,133,2
"CS5800iG",boiler,16,nrgsuppheating,total energy supplied heating,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating,5,0,1,135,2
"CS5800iG",boiler,16,dhw.nrgsupp,total energy warm supplied,uint24 (>=0<=16777214),kWh,false,sensor.boiler_dhw_total_energy_warm_supplied,sensor.boiler_dhw_nrgsupp,5,9,1,12,2
"CS5800iG",boiler,16,nrgsuppcooling,total energy supplied cooling,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling,5,0,1,137,2
"CS5800iG",boiler,16,nrgsupppool,total energy supplied pool,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool,5,0,1,139,2
"CS5800iG",boiler,16,hppower,compressor power output,uint16 (>=0<=3199),kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower,5,0,1/10,141,1
"CS5800iG",boiler,16,hpmaxpower,compressor max power,uint8 (>=0<=100),%,true,number.boiler_compressor_max_power,number.boiler_hpmaxpower,5,0,1,142,1
"CS5800iG",boiler,16,pvmaxcomp,pv compressor max power,uint8 (>=0<=25),kW,true,number.boiler_pv_compressor_max_power,number.boiler_pvmaxcomp,5,0,1/10,143,1
"CS5800iG",boiler,16,powerreduction,power reduction,uint8 (>=30<=60),%,true,number.boiler_power_reduction,number.boiler_powerreduction,5,0,10,144,1
"CS5800iG",boiler,16,hpsetdiffpress,set differential pressure,uint8 (>=150<=750),mbar,true,number.boiler_set_differential_pressure,number.boiler_hpsetdiffpress,5,0,50,145,1
"CS5800iG",boiler,16,hpcompon,hp compressor,boolean, ,false,binary_sensor.boiler_hp_compressor,binary_sensor.boiler_hpcompon,5,0,1,146,1
"CS5800iG",boiler,16,hpactivity,compressor activity,enum [off\|heating\|cooling\|hot water\|pool\|pool heating\|defrost\|compressor alarm], ,false,sensor.boiler_compressor_activity,sensor.boiler_hpactivity,5,0,1,147,1
"CS5800iG",boiler,16,hpbrinepumpspd,brine pump speed,uint8 (>=0<=100),%,false,sensor.boiler_brine_pump_speed,sensor.boiler_hpbrinepumpspd,5,0,1,148,1
"CS5800iG",boiler,16,hpswitchvalve,switch valve,boolean, ,false,binary_sensor.boiler_switch_valve,binary_sensor.boiler_hpswitchvalve,5,0,1,149,1
"CS5800iG",boiler,16,hpcompspd,compressor speed,uint8 (>=0<=100),%,false,sensor.boiler_compressor_speed,sensor.boiler_hpcompspd,5,0,1,150,1
"CS5800iG",boiler,16,hpcircspd,circulation pump speed,uint8 (>=0<=100),%,false,sensor.boiler_circulation_pump_speed,sensor.boiler_hpcircspd,5,0,1,151,1
"CS5800iG",boiler,16,hpbrinein,brine in/evaporator,int16 (>=-3199<=3199),C,false,sensor.boiler_brine_in/evaporator,sensor.boiler_hpbrinein,5,0,1/10,152,1
"CS5800iG",boiler,16,hpbrineout,brine out/condenser,int16 (>=-3199<=3199),C,false,sensor.boiler_brine_out/condenser,sensor.boiler_hpbrineout,5,0,1/10,153,1
"CS5800iG",boiler,16,hptc0,heat carrier return (TC0),int16 (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_return_(TC0),sensor.boiler_hptc0,5,0,1/10,154,1
"CS5800iG",boiler,16,hptc1,heat carrier forward (TC1),int16 (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_forward_(TC1),sensor.boiler_hptc1,5,0,1/10,155,1
"CS5800iG",boiler,16,hptc3,condenser temperature (TC3),int16 (>=-3199<=3199),C,false,sensor.boiler_condenser_temperature_(TC3),sensor.boiler_hptc3,5,0,1/10,156,1
"CS5800iG",boiler,16,hptr1,compressor temperature (TR1),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_temperature_(TR1),sensor.boiler_hptr1,5,0,1/10,157,1
"CS5800iG",boiler,16,hptr3,refrigerant temperature liquid side (condenser output) (TR3),int16 (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.boiler_hptr3,5,0,1/10,158,1
"CS5800iG",boiler,16,hptr4,evaporator inlet temperature (TR4),int16 (>=-3199<=3199),C,false,sensor.boiler_evaporator_inlet_temperature_(TR4),sensor.boiler_hptr4,5,0,1/10,159,1
"CS5800iG",boiler,16,hptr5,compressor inlet temperature (TR5),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_inlet_temperature_(TR5),sensor.boiler_hptr5,5,0,1/10,160,1
"CS5800iG",boiler,16,hptr6,compressor outlet temperature (TR6),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_outlet_temperature_(TR6),sensor.boiler_hptr6,5,0,1/10,161,1
"CS5800iG",boiler,16,hptr7,refrigerant temperature gas side (condenser input) (TR7),int16 (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7),sensor.boiler_hptr7,5,0,1/10,162,1
"CS5800iG",boiler,16,hptl2,air inlet temperature (TL2),int16 (>=-3199<=3199),C,false,sensor.boiler_air_inlet_temperature_(TL2),sensor.boiler_hptl2,5,0,1/10,163,1
"CS5800iG",boiler,16,hppl1,low pressure side temperature (PL1),int16 (>=-3199<=3199),C,false,sensor.boiler_low_pressure_side_temperature_(PL1),sensor.boiler_hppl1,5,0,1/10,164,1
"CS5800iG",boiler,16,hpph1,high pressure side temperature (PH1),int16 (>=-3199<=3199),C,false,sensor.boiler_high_pressure_side_temperature_(PH1),sensor.boiler_hpph1,5,0,1/10,165,1
"CS5800iG",boiler,16,hpta4,drain pan temp (TA4),int16 (>=-3199<=3199),C,false,sensor.boiler_drain_pan_temp_(TA4),sensor.boiler_hpta4,5,0,1/10,166,1
"CS5800iG",boiler,16,hptw1,reservoir temp (TW1),int16 (>=-3199<=3199),C,false,sensor.boiler_reservoir_temp_(TW1),sensor.boiler_hptw1,5,0,1/10,167,1
"CS5800iG",boiler,16,poolsettemp,pool set temperature,uint8 (>=0<=127),C,true,number.boiler_pool_set_temperature,number.boiler_poolsettemp,5,0,1/2,168,1
"CS5800iG",boiler,16,hp4way,4-way valve (VR4),enum [cooling & defrost\|heating & dhw], ,false,sensor.boiler_4-way_valve_(VR4),sensor.boiler_hp4way,5,0,1,169,1
"CS5800iG",boiler,16,hpin1,input 1 state,boolean, ,false,binary_sensor.boiler_input_1_state,binary_sensor.boiler_hpin1,5,0,1,170,1
"CS5800iG",boiler,16,hpin1opt,input 1 options,string, ,true,sensor.boiler_input_1_options,sensor.boiler_hpin1opt,5,0,1,171,8
"CS5800iG",boiler,16,hpin2,input 2 state,boolean, ,false,binary_sensor.boiler_input_2_state,binary_sensor.boiler_hpin2,5,0,1,179,1
"CS5800iG",boiler,16,hpin2opt,input 2 options,string, ,true,sensor.boiler_input_2_options,sensor.boiler_hpin2opt,5,0,1,180,8
"CS5800iG",boiler,16,hpin3,input 3 state,boolean, ,false,binary_sensor.boiler_input_3_state,binary_sensor.boiler_hpin3,5,0,1,188,1
"CS5800iG",boiler,16,hpin3opt,input 3 options,string, ,true,sensor.boiler_input_3_options,sensor.boiler_hpin3opt,5,0,1,189,8
"CS5800iG",boiler,16,hpin4,input 4 state,boolean, ,false,binary_sensor.boiler_input_4_state,binary_sensor.boiler_hpin4,5,0,1,197,1
"CS5800iG",boiler,16,hpin4opt,input 4 options,string, ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt,5,0,1,198,8
"CS5800iG",boiler,16,maxheatcomp,heat limit compressor,enum [0 kW\|3 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp,5,0,1,206,1
"CS5800iG",boiler,16,maxheatheat,heat limit heating,enum [3 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat,5,0,1,207,1
"CS5800iG",boiler,16,dhw.maxheat,heat limit,enum [3 kW\|6 kW\|9 kW], ,true,select.boiler_dhw_heat_limit,select.boiler_dhw_maxheat,5,9,1,14,1
"CS5800iG",boiler,16,auxheatersource,aux heater source,enum [not installed\|electric heater\|exclusive\|parallel\|hybrid], ,true,select.boiler_aux_heater_source,select.boiler_auxheatersource,5,0,1,208,1
"CS5800iG",boiler,16,pvcooling,cooling only with PV,boolean, ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling,5,0,1,209,1
"CS5800iG",boiler,16,auxheateronly,aux heater only,boolean, ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly,5,0,1,210,1
"CS5800iG",boiler,16,auxheateroff,disable aux heater,boolean, ,true,switch.boiler_disable_aux_heater,switch.boiler_auxheateroff,5,0,1,211,1
"CS5800iG",boiler,16,auxheaterstatus,aux heater status,enum [off\|heating\|cooling\|hot water\|pool\|pool heating\|defrost\|compressor alarm], ,false,sensor.boiler_aux_heater_status,sensor.boiler_auxheaterstatus,5,0,1,212,1
"CS5800iG",boiler,16,auxheaterlevel,aux heater level,uint8 (>=0<=100),%,false,sensor.boiler_aux_heater_level,sensor.boiler_auxheaterlevel,5,0,1,213,1
"CS5800iG",boiler,16,auxheaterdelay,aux heater on delay,uint16 (>=10<=1000),K*min,true,number.boiler_aux_heater_on_delay,number.boiler_auxheaterdelay,5,0,10,214,1
"CS5800iG",boiler,16,auxmaxlimit,aux heater max limit,uint8 (>=0<=10),K,true,number.boiler_aux_heater_max_limit,number.boiler_auxmaxlimit,5,0,1/10,215,1
"CS5800iG",boiler,16,auxlimitstart,aux heater limit start,uint8 (>=0<=10),K,true,number.boiler_aux_heater_limit_start,number.boiler_auxlimitstart,5,0,1/10,216,1
"CS5800iG",boiler,16,auxheatrmode,aux heater mode,enum [eco\|comfort], ,true,select.boiler_aux_heater_mode,select.boiler_auxheatrmode,5,0,1,217,1
"CS5800iG",boiler,16,hphystheat,on/off hyst heat,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_heat,number.boiler_hphystheat,5,0,5,218,1
"CS5800iG",boiler,16,hphystcool,on/off hyst cool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_cool,number.boiler_hphystcool,5,0,5,219,1
"CS5800iG",boiler,16,hphystpool,on/off hyst pool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_pool,number.boiler_hphystpool,5,0,5,220,1
"CS5800iG",boiler,16,silentmode,silent mode,enum [off\|auto\|on], ,true,select.boiler_silent_mode,select.boiler_silentmode,5,0,1,221,1
"CS5800iG",boiler,16,silentfrom,silent mode from,uint8 (>=0<=3810),minutes,true,number.boiler_silent_mode_from,number.boiler_silentfrom,5,0,15,222,1
"CS5800iG",boiler,16,silentto,silent mode to,uint8 (>=0<=3810),minutes,true,number.boiler_silent_mode_to,number.boiler_silentto,5,0,15,223,1
"CS5800iG",boiler,16,mintempsilent,min outside temp for silent mode,int8 (>=-126<=126),C,true,number.boiler_min_outside_temp_for_silent_mode,number.boiler_mintempsilent,5,0,1,224,1
"CS5800iG",boiler,16,tempparmode,outside temp parallel mode,int8 (>=-126<=126),C,true,number.boiler_outside_temp_parallel_mode,number.boiler_tempparmode,5,0,1,225,1
"CS5800iG",boiler,16,auxheatmix,aux heater mixing valve,int8 (>=-100<=100),%,false,sensor.boiler_aux_heater_mixing_valve,sensor.boiler_auxheatmix,5,0,1,226,1
"CS5800iG",boiler,16,tempdiffheat,temp diff TC3/TC0 heat,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_heat,number.boiler_tempdiffheat,5,0,1/10,227,1
"CS5800iG",boiler,16,tempdiffcool,temp diff TC3/TC0 cool,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_cool,number.boiler_tempdiffcool,5,0,1/10,228,1
"CS5800iG",boiler,16,vpcooling,valve/pump cooling,boolean, ,true,switch.boiler_valve/pump_cooling,switch.boiler_vpcooling,5,0,1,229,1
"CS5800iG",boiler,16,heatcable,heating cable,boolean, ,true,switch.boiler_heating_cable,switch.boiler_heatcable,5,0,1,230,1
"CS5800iG",boiler,16,vc0valve,VC0 valve,boolean, ,true,switch.boiler_VC0_valve,switch.boiler_vc0valve,5,0,1,231,1
"CS5800iG",boiler,16,primepump,primary heatpump,boolean, ,true,switch.boiler_primary_heatpump,switch.boiler_primepump,5,0,1,232,1
"CS5800iG",boiler,16,primepumpmod,primary heatpump modulation,uint8 (>=0<=100),%,true,number.boiler_primary_heatpump_modulation,number.boiler_primepumpmod,5,0,1,233,1
"CS5800iG",boiler,16,hp3way,3-way valve,boolean, ,true,switch.boiler_3-way_valve,switch.boiler_hp3way,5,0,1,234,1
"CS5800iG",boiler,16,elheatstep1,el. heater step 1,boolean, ,true,switch.boiler_el._heater_step_1,switch.boiler_elheatstep1,5,0,1,235,1
"CS5800iG",boiler,16,elheatstep2,el. heater step 2,boolean, ,true,switch.boiler_el._heater_step_2,switch.boiler_elheatstep2,5,0,1,236,1
"CS5800iG",boiler,16,elheatstep3,el. heater step 3,boolean, ,true,switch.boiler_el._heater_step_3,switch.boiler_elheatstep3,5,0,1,237,1
"CS5800iG",boiler,16,hpea0,condensate reservoir heating (EA0),boolean, ,false,binary_sensor.boiler_condensate_reservoir_heating_(EA0),binary_sensor.boiler_hpea0,5,0,1,238,1
"CS5800iG",boiler,16,hppumpmode,primary heatpump mode,enum [auto\|continuous], ,true,select.boiler_primary_heatpump_mode,select.boiler_hppumpmode,5,0,1,239,1
"CS5800iG",boiler,16,fan,fan,uint8 (>=20<=100),%,true,number.boiler_fan,number.boiler_fan,5,0,1,240,1
"CS5800iG",boiler,16,shutdown,shutdown,cmd [off\|on], ,true,sensor.boiler_shutdown,sensor.boiler_shutdown,5,0,1,241,1
"CS5800iG",boiler,16,hpcurrpower,compressor current power,uint16 (>=0<=31999),W,false,sensor.boiler_compressor_current_power,sensor.boiler_hpcurrpower,5,0,1,242,1
"CS5800iG",boiler,16,hppowerlimit,power limit,uint16 (>=0<=31999),W,true,number.boiler_power_limit,number.boiler_hppowerlimit,5,0,1,243,1
"CS5800iG",boiler,16,dhw.alternatingop,alternating operation,boolean, ,true,switch.boiler_dhw_alternating_operation,switch.boiler_dhw_alternatingop,5,9,1,15,1
"CS5800iG",boiler,16,dhw.altopprioheat,prioritise heating during dhw,uint8 (>=20<=120),minutes,true,number.boiler_dhw_prioritise_heating_during_dhw,number.boiler_dhw_altopprioheat,5,9,1,16,1
"CS5800iG",boiler,16,dhw.altopprio,prioritise dhw during heating,uint8 (>=30<=120),minutes,true,number.boiler_dhw_prioritise_dhw_during_heating,number.boiler_dhw_altopprio,5,9,1,17,1
"CS5800iG",boiler,16,dhw.comfoff,comfort switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_comfort_switch_off,number.boiler_dhw_comfoff,5,9,1,18,1
"CS5800iG",boiler,16,dhw.ecooff,eco switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_eco_switch_off,number.boiler_dhw_ecooff,5,9,1,19,1
"CS5800iG",boiler,16,dhw.ecoplusoff,eco+ switch off,uint8 (>=48<=63),C,true,number.boiler_dhw_eco+_switch_off,number.boiler_dhw_ecoplusoff,5,9,1,20,1
"CS5800iG",boiler,16,dhw.comfdiff,comfort diff,uint8 (>=6<=12),K,true,number.boiler_dhw_comfort_diff,number.boiler_dhw_comfdiff,5,9,1,21,1
"CS5800iG",boiler,16,dhw.ecodiff,eco diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco_diff,number.boiler_dhw_ecodiff,5,9,1,22,1
"CS5800iG",boiler,16,dhw.ecoplusdiff,eco+ diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco+_diff,number.boiler_dhw_ecoplusdiff,5,9,1,23,1
"CS5800iG",boiler,16,dhw.comfstop,comfort stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_comfort_stop_temp,number.boiler_dhw_comfstop,5,9,1,24,1
"CS5800iG",boiler,16,dhw.ecostop,eco stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco_stop_temp,number.boiler_dhw_ecostop,5,9,1,25,1
"CS5800iG",boiler,16,dhw.ecoplusstop,eco+ stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco+_stop_temp,number.boiler_dhw_ecoplusstop,5,9,1,26,1
"CS5800iG",boiler,16,dhw.hpcircpump,circulation pump available during dhw,boolean, ,true,switch.boiler_dhw_circulation_pump_available_during_dhw,switch.boiler_dhw_hpcircpump,5,9,1,27,1
"CS5800iG",boiler,16,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,95,2
"CS5800iG",boiler,16,dhw.meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2
"CS5800iG",boiler,16,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,266,2
"CS5800iG",boiler,16,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2
"CS5800iG",boiler,16,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,268,2
"CS5800iG",boiler,16,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2
"CS5800iG",boiler,16,dhw.tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1
"CS5800iG",boiler,16,dhw.settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1
"CS5800iG",boiler,16,dhw.seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1
@@ -530,6 +433,10 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/
"CS5800iG",boiler,16,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1
"CS5800iG",boiler,16,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2
"CS5800iG",boiler,16,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2
"CS5800iG",boiler,16,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,270,1
"CS5800iG",boiler,16,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,83,2
"CS5800iG",boiler,16,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,85,2
"CS5800iG",boiler,16,dhw.nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2
"BK13/BK15, Smartline, GB1*2",boiler,64,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1
"BK13/BK15, Smartline, GB1*2",boiler,64,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1
"BK13/BK15, Smartline, GB1*2",boiler,64,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1
@@ -5517,6 +5424,53 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/
"Hybrid Manager HM200",heatpump,248,dhw.eldhw,el. consumption,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_dhw_el._consumption,sensor.heatpump_dhw_eldhw,9,9,1/10,9,2
"Hybrid Manager HM200",heatpump,248,elgenheat,el. generation heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_el._generation_heating,sensor.heatpump_elgenheat,9,0,1/10,48,2
"Hybrid Manager HM200",heatpump,248,dhw.elgendhw,el generation,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_dhw_el_generation,sensor.heatpump_dhw_elgendhw,9,9,1/10,11,2
"CSH5800iG",heatpump,16,airhumidity,relative air humidity,uint8 (>=0<=100),%,false,sensor.heatpump_relative_air_humidity,sensor.heatpump_airhumidity,9,0,1,0,1
"CSH5800iG",heatpump,16,dewtemperature,dew point temperature,uint8 (>=0<=254),C,false,sensor.heatpump_dew_point_temperature,sensor.heatpump_dewtemperature,9,0,1,1,1
"CSH5800iG",heatpump,16,curflowtemp,current flow temperature,int16 (>=-3199<=3199),C,false,sensor.heatpump_current_flow_temperature,sensor.heatpump_curflowtemp,9,0,1/10,2,1
"CSH5800iG",heatpump,16,rettemp,return temperature,int16 (>=-3199<=3199),C,false,sensor.heatpump_return_temperature,sensor.heatpump_rettemp,9,0,1/10,3,1
"CSH5800iG",heatpump,16,sysrettemp,system return temperature,int16 (>=-3199<=3199),C,false,sensor.heatpump_system_return_temperature,sensor.heatpump_sysrettemp,9,0,1/10,4,1
"CSH5800iG",heatpump,16,hpta4,drain pan temp (TA4),int16 (>=-3199<=3199),C,false,sensor.heatpump_drain_pan_temp_(TA4),sensor.heatpump_hpta4,9,0,1/10,5,1
"CSH5800iG",heatpump,16,hptr1,compressor temperature (TR1),int16 (>=-3199<=3199),C,false,sensor.heatpump_compressor_temperature_(TR1),sensor.heatpump_hptr1,9,0,1/10,6,1
"CSH5800iG",heatpump,16,hptr3,refrigerant temperature liquid side (condenser output) (TR3),int16 (>=-3199<=3199),C,false,sensor.heatpump_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.heatpump_hptr3,9,0,1/10,7,1
"CSH5800iG",heatpump,16,hptr4,evaporator inlet temperature (TR4),int16 (>=-3199<=3199),C,false,sensor.heatpump_evaporator_inlet_temperature_(TR4),sensor.heatpump_hptr4,9,0,1/10,8,1
"CSH5800iG",heatpump,16,hptr5,compressor inlet temperature (TR5),int16 (>=-3199<=3199),C,false,sensor.heatpump_compressor_inlet_temperature_(TR5),sensor.heatpump_hptr5,9,0,1/10,9,1
"CSH5800iG",heatpump,16,hptr6,compressor outlet temperature (TR6),int16 (>=-3199<=3199),C,false,sensor.heatpump_compressor_outlet_temperature_(TR6),sensor.heatpump_hptr6,9,0,1/10,10,1
"CSH5800iG",heatpump,16,hptl2,air inlet temperature (TL2),int16 (>=-3199<=3199),C,false,sensor.heatpump_air_inlet_temperature_(TL2),sensor.heatpump_hptl2,9,0,1/10,11,1
"CSH5800iG",heatpump,16,hppl1,low pressure side temperature (PL1),int16 (>=-3199<=3199),C,false,sensor.heatpump_low_pressure_side_temperature_(PL1),sensor.heatpump_hppl1,9,0,1/10,12,1
"CSH5800iG",heatpump,16,hpph1,high pressure side temperature (PH1),int16 (>=-3199<=3199),C,false,sensor.heatpump_high_pressure_side_temperature_(PH1),sensor.heatpump_hpph1,9,0,1/10,13,1
"CSH5800iG",heatpump,16,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.heatpump_heating_pump_modulation,sensor.heatpump_heatingpumpmod,9,0,1,14,1
"CSH5800iG",heatpump,16,hpcompspd,compressor speed,uint8 (>=0<=100),%,false,sensor.heatpump_compressor_speed,sensor.heatpump_hpcompspd,9,0,1,15,1
"CSH5800iG",heatpump,16,hybridstrategy,hybrid control strategy,enum [cost optimized\|co2 optimized\|outside temperature alt.\|outside temperature parallel\|heatpump preferred\|boiler only], ,true,select.heatpump_hybrid_control_strategy,select.heatpump_hybridstrategy,9,0,1,16,1
"CSH5800iG",heatpump,16,lownoisemode,low noise mode,enum [off\|reduced output\|switch off hp\|perm. reduced], ,true,select.heatpump_low_noise_mode,select.heatpump_lownoisemode,9,0,1,17,1
"CSH5800iG",heatpump,16,lownoisestart,low noise starttime,uint8 (>=0<=23),hours,true,number.heatpump_low_noise_starttime,number.heatpump_lownoisestart,9,0,1,18,1
"CSH5800iG",heatpump,16,lownoisestop,low noise stoptime,uint8 (>=0<=23),hours,true,number.heatpump_low_noise_stoptime,number.heatpump_lownoisestop,9,0,1,19,1
"CSH5800iG",heatpump,16,dhw.hybriddhw,hybrid DHW,enum [eco\|high comfort], ,true,select.heatpump_dhw_hybrid_DHW,select.heatpump_dhw_hybriddhw,9,9,1,0,1
"CSH5800iG",heatpump,16,energypricegas,energy price gas,uint8 (>=0<=254),ct/kWh,true,number.heatpump_energy_price_gas,number.heatpump_energypricegas,9,0,1,20,1
"CSH5800iG",heatpump,16,energypriceel,energy price electric,uint8 (>=0<=254),ct/kWh,true,number.heatpump_energy_price_electric,number.heatpump_energypriceel,9,0,1,21,1
"CSH5800iG",heatpump,16,energyfeedpv,feed in PV,uint8 (>=0<=254),ct/kWh,true,number.heatpump_feed_in_PV,number.heatpump_energyfeedpv,9,0,1,22,1
"CSH5800iG",heatpump,16,switchovertemp,outside switchover temperature,int8 (>=-126<=126),C,true,number.heatpump_outside_switchover_temperature,number.heatpump_switchovertemp,9,0,1,23,1
"CSH5800iG",heatpump,16,airpurgemode,air purge mode,boolean, ,true,switch.heatpump_air_purge_mode,switch.heatpump_airpurgemode,9,0,1,24,1
"CSH5800iG",heatpump,16,heatpumpoutput,heatpump output,uint8 (>=0<=100),%,true,number.heatpump_heatpump_output,number.heatpump_heatpumpoutput,9,0,1,25,1
"CSH5800iG",heatpump,16,coolingcircuit,cooling circuit,boolean, ,true,switch.heatpump_cooling_circuit,switch.heatpump_coolingcircuit,9,0,1,26,1
"CSH5800iG",heatpump,16,compstartmod,compressor start modulation,uint8 (>=0<=100),%,true,number.heatpump_compressor_start_modulation,number.heatpump_compstartmod,9,0,1,27,1
"CSH5800iG",heatpump,16,heatdrainpan,heat drain pan,boolean, ,true,switch.heatpump_heat_drain_pan,switch.heatpump_heatdrainpan,9,0,1,28,1
"CSH5800iG",heatpump,16,heatcable,heating cable,boolean, ,true,switch.heatpump_heating_cable,switch.heatpump_heatcable,9,0,1,29,1
"CSH5800iG",heatpump,16,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.heatpump_total_energy,sensor.heatpump_nrgtotal,9,0,1/100,30,2
"CSH5800iG",heatpump,16,dhw.nrg,energy,uint24 (>=0<=167772),kWh,false,sensor.heatpump_dhw_energy,sensor.heatpump_dhw_nrg,9,9,1/100,1,2
"CSH5800iG",heatpump,16,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_energy_heating,sensor.heatpump_nrgheat,9,0,1/100,32,2
"CSH5800iG",heatpump,16,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_total,sensor.heatpump_metertotal,9,0,1/100,34,2
"CSH5800iG",heatpump,16,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_compressor,sensor.heatpump_metercomp,9,0,1/100,36,2
"CSH5800iG",heatpump,16,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_e-heater,sensor.heatpump_metereheat,9,0,1/100,38,2
"CSH5800iG",heatpump,16,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_heating,sensor.heatpump_meterheat,9,0,1/100,40,2
"CSH5800iG",heatpump,16,dhw.meter,meter,uint24 (>=0<=167772),kWh,false,sensor.heatpump_dhw_meter,sensor.heatpump_dhw_meter,9,9,1/100,3,2
"CSH5800iG",heatpump,16,heatingstarts,heating control starts,uint24 (>=0<=16777214), ,false,sensor.heatpump_heating_control_starts,sensor.heatpump_heatingstarts,9,0,1,42,2
"CSH5800iG",heatpump,16,dhw.startshp,starts hp,uint24 (>=0<=16777214), ,false,sensor.heatpump_dhw_starts_hp,sensor.heatpump_dhw_startshp,9,9,1,5,2
"CSH5800iG",heatpump,16,fuelheat,fuel consumption heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_fuel_consumption_heating,sensor.heatpump_fuelheat,9,0,1/10,44,2
"CSH5800iG",heatpump,16,dhw.fueldhw,fuel consumption,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_dhw_fuel_consumption,sensor.heatpump_dhw_fueldhw,9,9,1/10,7,2
"CSH5800iG",heatpump,16,elheat,el. consumption heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_el._consumption_heating,sensor.heatpump_elheat,9,0,1/10,46,2
"CSH5800iG",heatpump,16,dhw.eldhw,el. consumption,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_dhw_el._consumption,sensor.heatpump_dhw_eldhw,9,9,1/10,9,2
"CSH5800iG",heatpump,16,elgenheat,el. generation heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_el._generation_heating,sensor.heatpump_elgenheat,9,0,1/10,48,2
"CSH5800iG",heatpump,16,dhw.elgendhw,el generation,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_dhw_el_generation,sensor.heatpump_dhw_elgendhw,9,9,1/10,11,2
"WM10",switch,71,activated,activated,boolean, ,false,binary_sensor.switch_activated,binary_sensor.switch_activated,11,0,1,0,1
"WM10",switch,71,flowtemphc,flow temperature (TC1),uint16 (>=0<=3199),C,false,sensor.switch_flow_temperature_(TC1),sensor.switch_flowtemphc,11,0,1/10,1,1
"WM10",switch,71,status,status,int8 (>=-126<=126), ,false,sensor.switch_status,sensor.switch_status,11,0,1,2,1