ensure heating_active and tapwater_active MQTT topics are sent on cold start
This commit is contained in:
@@ -52,7 +52,7 @@ class Boiler : public EMSdevice {
|
||||
|
||||
void print_value2(uuid::console::Shell & shell, const char * param, const __FlashStringHelper * name, const __FlashStringHelper * suffix, JsonObject & json);
|
||||
|
||||
uint8_t last_boilerState = 0xFF; // remember last state of heating and warm water on/off
|
||||
uint8_t last_boilerState = EMS_VALUE_UINT_NOTSET; // remember last state of heating and warm water on/off
|
||||
bool changed_ = false;
|
||||
bool mqtt_ha_config_ = false; // HA MQTT Discovery
|
||||
|
||||
@@ -97,7 +97,7 @@ class Boiler : public EMSdevice {
|
||||
uint8_t sysPress_ = EMS_VALUE_UINT_NOTSET; // System pressure
|
||||
char serviceCode_[3] = {'\0'}; // 2 character status/service code
|
||||
uint16_t serviceCodeNumber_ = EMS_VALUE_USHORT_NOTSET; // error/service code
|
||||
uint8_t boilerState_ = EMS_VALUE_BOOL_NOTSET; // State flag, used on HT3
|
||||
uint8_t boilerState_ = EMS_VALUE_UINT_NOTSET; // Boiler state flag
|
||||
|
||||
// UBAMonitorSlow - 0x19 on EMS1
|
||||
int16_t outdoorTemp_ = EMS_VALUE_SHORT_NOTSET; // Outside temperature
|
||||
|
||||