mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-08 00:39:50 +03:00
Merge pull request #128 from Vuego123:Added-Thermostat-Junkers-FW100
Added support for Junkers FW100
This commit is contained in:
17
src/ems.cpp
17
src/ems.cpp
@@ -95,8 +95,8 @@ void _process_RCPLUSStatusHeating(_EMS_RxTelegram * EMS_RxTelegram);
|
||||
void _process_RCPLUSStatusHeating(_EMS_RxTelegram * EMS_RxTelegram);
|
||||
void _process_RCPLUSStatusMode(_EMS_RxTelegram * EMS_RxTelegram);
|
||||
|
||||
// Junkers FR10
|
||||
void _process_FR10StatusMessage(_EMS_RxTelegram * EMS_RxTelegram);
|
||||
// Junkers FR10 & FW100
|
||||
void _process_JunkersStatusMessage(_EMS_RxTelegram * EMS_RxTelegram);
|
||||
|
||||
/**
|
||||
* Recognized EMS types and the functions they call to process the telegrams
|
||||
@@ -173,7 +173,7 @@ const _EMS_Type EMS_Types[] = {
|
||||
{EMS_MODEL_ALL, EMS_TYPE_RCPLUSStatusMode, "RCPLUSStatusMode", _process_RCPLUSStatusMode},
|
||||
|
||||
// Junkers FR10
|
||||
{EMS_MODEL_ALL, EMS_TYPE_FR10StatusMessage, "FR10StatusMessage", _process_FR10StatusMessage}
|
||||
{EMS_MODEL_ALL, EMS_TYPE_JunkersStatusMessage, "JunkersStatusMessage", _process_JunkersStatusMessage}
|
||||
|
||||
|
||||
};
|
||||
@@ -1304,12 +1304,11 @@ void _process_RCPLUSStatusMode(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
/**
|
||||
* FR10 Junkers - type x6F01
|
||||
*/
|
||||
void _process_FR10StatusMessage(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
if (EMS_RxTelegram->data_length == 6) {
|
||||
// e.g. 90 00 FF 00 00 6F 03 01 00 BE 00 BF
|
||||
EMS_Thermostat.curr_roomTemp = _toByte(EMS_OFFSET_FR10StatusMessage_curr); // value is * 10
|
||||
EMS_Thermostat.setpoint_roomTemp = _toByte(EMS_OFFSET_FR10StatusMessage_setpoint); // value is * 10, which is different from other EMS+ devices
|
||||
}
|
||||
void _process_JunkersStatusMessage(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
// e.g. for FR10: 90 00 FF 00 00 6F 03 01 00 BE 00 BF
|
||||
// e.g. for FW100: 90 00 FF 00 00 6F 03 02 00 D7 00 DA F3 34 00 C4
|
||||
EMS_Thermostat.curr_roomTemp = _toShort(EMS_OFFSET_JunkersStatusMessage_curr); // value is * 10
|
||||
EMS_Thermostat.setpoint_roomTemp = _toShort(EMS_OFFSET_JunkersStatusMessage_setpoint); // value is * 10
|
||||
}
|
||||
|
||||
/**
|
||||
|
||||