mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-08 00:39:50 +03:00
version 1.4.0. See ChangeLog
This commit is contained in:
34
src/ems.cpp
34
src/ems.cpp
@@ -22,16 +22,20 @@ _EMS_Sys_Status EMS_Sys_Status; // EMS Status
|
||||
CircularBuffer<_EMS_TxTelegram, EMS_TX_TELEGRAM_QUEUE_MAX> EMS_TxQueue; // FIFO queue for Tx send buffer
|
||||
|
||||
// callbacks per type
|
||||
// Boiler and Buderus devices
|
||||
|
||||
// generic
|
||||
void _process_Version(uint8_t * data, uint8_t length);
|
||||
|
||||
// Boiler and Buderus devices
|
||||
void _process_UBAMonitorFast(uint8_t * data, uint8_t length);
|
||||
void _process_UBAMonitorSlow(uint8_t * data, uint8_t length);
|
||||
void _process_UBAMonitorWWMessage(uint8_t * data, uint8_t length);
|
||||
void _process_UBAParameterWW(uint8_t * data, uint8_t length);
|
||||
void _process_UBATotalUptimeMessage(uint8_t * data, uint8_t length);
|
||||
void _process_UBAParametersMessage(uint8_t * data, uint8_t length);
|
||||
void _process_SetPoints(uint8_t * data, uint8_t length);
|
||||
|
||||
// Common for most thermostats
|
||||
void _process_SetPoints(uint8_t * data, uint8_t length);
|
||||
void _process_RCTime(uint8_t * data, uint8_t length);
|
||||
void _process_RCOutdoorTempMessage(uint8_t * data, uint8_t length);
|
||||
|
||||
@@ -66,8 +70,7 @@ const _EMS_Type EMS_Types[] = {
|
||||
{EMS_MODEL_UBA, EMS_TYPE_UBAParameterWW, "UBAParameterWW", _process_UBAParameterWW},
|
||||
{EMS_MODEL_UBA, EMS_TYPE_UBATotalUptimeMessage, "UBATotalUptimeMessage", _process_UBATotalUptimeMessage},
|
||||
{EMS_MODEL_UBA, EMS_TYPE_UBAMaintenanceSettingsMessage, "UBAMaintenanceSettingsMessage", NULL},
|
||||
{EMS_MODEL_UBA, EMS_TYPE_UBAParametersMessage, "UBAParametersMessage", NULL},
|
||||
{EMS_MODEL_UBA, EMS_TYPE_UBAMaintenanceStatusMessage, "UBAMaintenanceStatusMessage", NULL},
|
||||
{EMS_MODEL_UBA, EMS_TYPE_UBAParametersMessage, "UBAParametersMessage", _process_UBAParametersMessage},
|
||||
{EMS_MODEL_UBA, EMS_TYPE_UBASetPoints, "UBASetPoints", _process_SetPoints},
|
||||
|
||||
// RC20 and RC20F
|
||||
@@ -212,6 +215,12 @@ void ems_init(uint8_t thermostat_modelid) {
|
||||
// UBATotalUptimeMessage
|
||||
EMS_Boiler.UBAuptime = EMS_VALUE_LONG_NOTSET; // Total UBA working hours
|
||||
|
||||
// UBAParametersMessage
|
||||
EMS_Boiler.heating_temp = EMS_VALUE_INT_NOTSET; // Heating temperature setting on the boiler
|
||||
EMS_Boiler.pump_mod_max = EMS_VALUE_INT_NOTSET; // Boiler circuit pump modulation max. power
|
||||
EMS_Boiler.pump_mod_min = EMS_VALUE_INT_NOTSET; // Boiler circuit pump modulation min. power
|
||||
|
||||
// calculated values
|
||||
EMS_Boiler.tapwaterActive = EMS_VALUE_INT_NOTSET; // Hot tap water is on/off
|
||||
EMS_Boiler.heatingActive = EMS_VALUE_INT_NOTSET; // Central heating is on/off
|
||||
|
||||
@@ -569,11 +578,6 @@ void ems_parseTelegram(uint8_t * telegram, uint8_t length) {
|
||||
if (length == 1) {
|
||||
uint8_t value = telegram[0]; // 1st byte of data package
|
||||
|
||||
// TODO: remove, only for debugging why some people can't do a Tx
|
||||
//if ((value & 0x80) == 0x80) {
|
||||
// myDebug("Poll: %02X", value);
|
||||
//}
|
||||
|
||||
// check first for a Poll for us
|
||||
if (value == (EMS_ID_ME | 0x80)) {
|
||||
// store when we received a last poll
|
||||
@@ -886,6 +890,15 @@ void _process_UBATotalUptimeMessage(uint8_t * data, uint8_t length) {
|
||||
EMS_Sys_Status.emsRefreshed = true; // when we receieve this, lets force an MQTT publish
|
||||
}
|
||||
|
||||
/*
|
||||
* UBAParametersMessage - type 0x16
|
||||
*/
|
||||
void _process_UBAParametersMessage(uint8_t * data, uint8_t length) {
|
||||
EMS_Boiler.heating_temp = data[1];
|
||||
EMS_Boiler.pump_mod_max = data[9];
|
||||
EMS_Boiler.pump_mod_min = data[10];
|
||||
}
|
||||
|
||||
/**
|
||||
* UBAMonitorWWMessage - type 0x34 - warm water monitor. 19 bytes long
|
||||
* received every 10 seconds
|
||||
@@ -1298,6 +1311,7 @@ void ems_getBoilerValues() {
|
||||
ems_doReadCommand(EMS_TYPE_UBAMonitorFast, EMS_Boiler.type_id); // get boiler stats, instead of waiting 10secs for the broadcast
|
||||
ems_doReadCommand(EMS_TYPE_UBAMonitorSlow, EMS_Boiler.type_id); // get more boiler stats, instead of waiting 60secs for the broadcast
|
||||
ems_doReadCommand(EMS_TYPE_UBAParameterWW, EMS_Boiler.type_id); // get Warm Water values
|
||||
ems_doReadCommand(EMS_TYPE_UBAParametersMessage, EMS_Boiler.type_id); // get MC10 boiler values
|
||||
ems_doReadCommand(EMS_TYPE_UBATotalUptimeMessage, EMS_Boiler.type_id); // get Warm Water values
|
||||
}
|
||||
|
||||
@@ -1381,7 +1395,7 @@ char * ems_getBoilerDescription(char * buffer) {
|
||||
* Find the versions of our connected devices
|
||||
*/
|
||||
void ems_scanDevices() {
|
||||
myDebug("Scanning EMS bus for devices. This may take a few seconds...");
|
||||
myDebug("Scanning EMS bus for devices...");
|
||||
|
||||
// start refresh when scanning and forget anything devices we may have already set
|
||||
EMS_Thermostat.type_id = EMS_ID_NONE; // forget thermostat
|
||||
|
||||
Reference in New Issue