generic support for EMS+
This commit is contained in:
@@ -99,8 +99,8 @@ command_t PROGMEM project_cmds[] = {
|
||||
{true, "led_gpio <gpio>", "set the LED pin. Default is the onboard LED (D1=5)"},
|
||||
{true, "dallas_gpio <gpio>", "set the pin for external Dallas temperature sensors (D5=14)"},
|
||||
{true, "dallas_parasite <on | off>", "set to on if powering Dallas via parasite"},
|
||||
{true, "thermostat_type <type ID>", "set the thermostat type id (e.g. 10 for 0x10)"},
|
||||
{true, "boiler_type <type ID>", "set the boiler type id (e.g. 8 for 0x08)"},
|
||||
{true, "thermostat_type <device ID>", "set the thermostat type id (e.g. 10 for 0x10)"},
|
||||
{true, "boiler_type <device ID>", "set the boiler type id (e.g. 8 for 0x08)"},
|
||||
{true, "silent_mode <on | off>", "when on all automatic Tx is disabled"},
|
||||
{true, "shower_timer <on | off>", "notify via MQTT all shower durations"},
|
||||
{true, "shower_alert <on | off>", "send a warning of cold water after shower time is exceeded"},
|
||||
@@ -358,7 +358,7 @@ void showInfo() {
|
||||
myDebug("%sBoiler stats:%s", COLOR_BOLD_ON, COLOR_BOLD_OFF);
|
||||
|
||||
// version details
|
||||
myDebug(" Boiler type: %s", ems_getBoilerDescription(buffer_type));
|
||||
myDebug(" Boiler: %s", ems_getBoilerDescription(buffer_type));
|
||||
|
||||
// active stats
|
||||
if (ems_getBusConnected()) {
|
||||
@@ -461,7 +461,7 @@ void showInfo() {
|
||||
if (ems_getThermostatEnabled()) {
|
||||
myDebug(""); // newline
|
||||
myDebug("%sThermostat stats:%s", COLOR_BOLD_ON, COLOR_BOLD_OFF);
|
||||
myDebug(" Thermostat type: %s", ems_getThermostatDescription(buffer_type));
|
||||
myDebug(" Thermostat: %s", ems_getThermostatDescription(buffer_type));
|
||||
if ((ems_getThermostatModel() == EMS_MODEL_EASY) || (ems_getThermostatModel() == EMS_MODEL_BOSCHEASY)) {
|
||||
// for easy temps are * 100
|
||||
// also we don't have the time or mode
|
||||
@@ -796,7 +796,7 @@ void do_ledcheck() {
|
||||
void do_scanThermostat() {
|
||||
if ((ems_getBusConnected()) && (!myESP.getUseSerial())) {
|
||||
myDebug("> Scanning thermostat message type #0x%02X...", scanThermostat_count);
|
||||
ems_doReadCommand(scanThermostat_count, EMS_Thermostat.type_id);
|
||||
ems_doReadCommand(scanThermostat_count, EMS_Thermostat.device_id);
|
||||
scanThermostat_count++;
|
||||
}
|
||||
}
|
||||
@@ -913,13 +913,13 @@ bool FSCallback(MYESP_FSACTION action, const JsonObject json) {
|
||||
EMSESP_Status.dallas_parasite = json["dallas_parasite"];
|
||||
|
||||
// thermostat_type
|
||||
if (!(EMS_Thermostat.type_id = json["thermostat_type"])) {
|
||||
EMS_Thermostat.type_id = EMSESP_THERMOSTAT_TYPE; // set default
|
||||
if (!(EMS_Thermostat.device_id = json["thermostat_type"])) {
|
||||
EMS_Thermostat.device_id = EMSESP_THERMOSTAT_TYPE; // set default
|
||||
}
|
||||
|
||||
// boiler_type
|
||||
if (!(EMS_Boiler.type_id = json["boiler_type"])) {
|
||||
EMS_Boiler.type_id = EMSESP_BOILER_TYPE; // set default
|
||||
if (!(EMS_Boiler.device_id = json["boiler_type"])) {
|
||||
EMS_Boiler.device_id = EMSESP_BOILER_TYPE; // set default
|
||||
}
|
||||
|
||||
// silent mode
|
||||
@@ -950,8 +950,8 @@ bool FSCallback(MYESP_FSACTION action, const JsonObject json) {
|
||||
}
|
||||
|
||||
if (action == MYESP_FSACTION_SAVE) {
|
||||
json["thermostat_type"] = EMS_Thermostat.type_id;
|
||||
json["boiler_type"] = EMS_Boiler.type_id;
|
||||
json["thermostat_type"] = EMS_Thermostat.device_id;
|
||||
json["boiler_type"] = EMS_Boiler.device_id;
|
||||
|
||||
json["led"] = EMSESP_Status.led;
|
||||
json["led_gpio"] = EMSESP_Status.led_gpio;
|
||||
@@ -1039,13 +1039,13 @@ bool SettingsCallback(MYESP_FSACTION action, uint8_t wc, const char * setting, c
|
||||
|
||||
// thermostat_type
|
||||
if (strcmp(setting, "thermostat_type") == 0) {
|
||||
EMS_Thermostat.type_id = ((wc == 2) ? (uint8_t)strtol(value, 0, 16) : EMS_ID_NONE);
|
||||
EMS_Thermostat.device_id = ((wc == 2) ? (uint8_t)strtol(value, 0, 16) : EMS_ID_NONE);
|
||||
ok = true;
|
||||
}
|
||||
|
||||
// boiler_type
|
||||
if (strcmp(setting, "boiler_type") == 0) {
|
||||
EMS_Boiler.type_id = ((wc == 2) ? (uint8_t)strtol(value, 0, 16) : EMS_ID_NONE);
|
||||
EMS_Boiler.device_id = ((wc == 2) ? (uint8_t)strtol(value, 0, 16) : EMS_ID_NONE);
|
||||
ok = true;
|
||||
}
|
||||
|
||||
@@ -1113,18 +1113,18 @@ bool SettingsCallback(MYESP_FSACTION action, uint8_t wc, const char * setting, c
|
||||
myDebug(" dallas_gpio=%d", EMSESP_Status.dallas_gpio);
|
||||
myDebug(" dallas_parasite=%s", EMSESP_Status.dallas_parasite ? "on" : "off");
|
||||
|
||||
if (EMS_Thermostat.type_id == EMS_ID_NONE) {
|
||||
if (EMS_Thermostat.device_id == EMS_ID_NONE) {
|
||||
myDebug(" thermostat_type=<not set>");
|
||||
} else {
|
||||
myDebug(" thermostat_type=%02X", EMS_Thermostat.type_id);
|
||||
myDebug(" thermostat_type=%02X", EMS_Thermostat.device_id);
|
||||
}
|
||||
|
||||
myDebug(" heating_circuit=%d", EMSESP_Status.heating_circuit);
|
||||
|
||||
if (EMS_Boiler.type_id == EMS_ID_NONE) {
|
||||
if (EMS_Boiler.device_id == EMS_ID_NONE) {
|
||||
myDebug(" boiler_type=<not set>");
|
||||
} else {
|
||||
myDebug(" boiler_type=%02X", EMS_Boiler.type_id);
|
||||
myDebug(" boiler_type=%02X", EMS_Boiler.device_id);
|
||||
}
|
||||
|
||||
myDebug(" silent_mode=%s", EMSESP_Status.silent_mode ? "on" : "off");
|
||||
@@ -1243,7 +1243,7 @@ void TelnetCommandCallback(uint8_t wc, const char * commandLine) {
|
||||
ems_setThermostatMode(_readIntNumber());
|
||||
ok = true;
|
||||
} else if (strcmp(second_cmd, "read") == 0) {
|
||||
ems_doReadCommand(_readHexNumber(), EMS_Thermostat.type_id);
|
||||
ems_doReadCommand(_readHexNumber(), EMS_Thermostat.device_id);
|
||||
ok = true;
|
||||
} else if (strcmp(second_cmd, "scan") == 0) {
|
||||
startThermostatScan(_readIntNumber());
|
||||
@@ -1270,7 +1270,7 @@ void TelnetCommandCallback(uint8_t wc, const char * commandLine) {
|
||||
ok = true;
|
||||
}
|
||||
} else if (strcmp(second_cmd, "read") == 0) {
|
||||
ems_doReadCommand(_readHexNumber(), EMS_Boiler.type_id);
|
||||
ems_doReadCommand(_readHexNumber(), EMS_Boiler.device_id);
|
||||
ok = true;
|
||||
} else if (strcmp(second_cmd, "tapwater") == 0) {
|
||||
char * third_cmd = _readWord();
|
||||
|
||||