revert last change, only send thermostat MQTT if there is a setpoint temp
This commit is contained in:
@@ -1269,7 +1269,7 @@ void _process_RC35StatusMessage(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
_setValue8(EMS_RxTelegram, &EMS_Thermostat.hc[hc].setpoint_roomTemp, EMS_OFFSET_RC35StatusMessage_setpoint); // is * 2, force to single byte
|
||||
}
|
||||
|
||||
_setValue(EMS_RxTelegram, &EMS_Thermostat.hc[hc].curr_roomTemp, EMS_OFFSET_RC35StatusMessage_curr); // is * 10
|
||||
_setValue(EMS_RxTelegram, &EMS_Thermostat.hc[hc].curr_roomTemp, EMS_OFFSET_RC35StatusMessage_curr); // is * 10 - or 0x7D00 if thermostat is mounted on boiler
|
||||
_setValue(EMS_RxTelegram, &EMS_Thermostat.hc[hc].mode_type, EMS_OFFSET_RC35StatusMessage_mode, 1);
|
||||
_setValue(EMS_RxTelegram, &EMS_Thermostat.hc[hc].summer_mode, EMS_OFFSET_RC35StatusMessage_mode, 0);
|
||||
_setValue(EMS_RxTelegram, &EMS_Thermostat.hc[hc].holiday_mode, EMS_OFFSET_RC35StatusMessage_mode1, 5);
|
||||
@@ -1338,6 +1338,7 @@ void _process_RCPLUSStatusMessage(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
if (hc >= EMS_THERMOSTAT_MAXHC) {
|
||||
return; // invalid type
|
||||
}
|
||||
|
||||
EMS_Thermostat.hc[hc].active = true;
|
||||
|
||||