new entity forceHeatingOff sends every minute 0x1A
This commit is contained in:
@@ -10,6 +10,7 @@
|
||||
|
||||
- Detect old Tado thermostat, device-id 0x19, no entities
|
||||
- Some more HM200 entities [#500](https://github.com/emsesp/EMS-ESP32/issues/500)
|
||||
- Add entity to force heating off (for systems without thermostat) [#951](https://github.com/emsesp/EMS-ESP32/issues/951)
|
||||
|
||||
## Fixed
|
||||
|
||||
|
||||
@@ -100,7 +100,12 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
|
||||
// reset is a command uses a dummy variable which is always zero, shown as blank, but provides command enum options
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &reset_, DeviceValueType::CMD, FL_(enum_reset), FL_(reset), DeviceValueUOM::NONE, MAKE_CF_CB(set_reset));
|
||||
has_update(reset_, 0);
|
||||
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA,
|
||||
&forceHeatingOff_,
|
||||
DeviceValueType::BOOL,
|
||||
FL_(forceHeatingOff),
|
||||
DeviceValueUOM::NONE,
|
||||
MAKE_CF_CB(set_forceHeatingOff));
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &heatingActive_, DeviceValueType::BOOL, FL_(heatingActive), DeviceValueUOM::NONE);
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &tapwaterActive_, DeviceValueType::BOOL, FL_(tapwaterActive), DeviceValueUOM::NONE);
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &selFlowTemp_, DeviceValueType::UINT, FL_(selFlowTemp), DeviceValueUOM::DEGREES, MAKE_CF_CB(set_flow_temp));
|
||||
@@ -875,6 +880,10 @@ void Boiler::check_active(const bool force) {
|
||||
Mqtt::publish(F_(tapwater_active), Helpers::render_boolean(s, b));
|
||||
EMSESP::tap_water_active(b); // let EMS-ESP know, used in the Shower class
|
||||
}
|
||||
|
||||
if (forceHeatingOff_ == EMS_VALUE_BOOL_NOTSET) {
|
||||
forceHeatingOff_ = selFlowTemp_ == 0 ? EMS_VALUE_BOOL_ON : EMS_VALUE_BOOL_OFF;
|
||||
}
|
||||
}
|
||||
|
||||
// 0x18
|
||||
@@ -1075,6 +1084,11 @@ void Boiler::process_UBAMonitorSlow(std::shared_ptr<const Telegram> telegram) {
|
||||
has_update(telegram, burn2WorkMin_, 16, 3); // force to 3 bytes
|
||||
has_update(telegram, heatWorkMin_, 19, 3); // force to 3 bytes
|
||||
has_update(telegram, heatStarts_, 22, 3); // force to 3 bytes
|
||||
|
||||
if (forceHeatingOff_ == EMS_VALUE_BOOL_ON) {
|
||||
uint8_t data[4] = {0, 0, 0, 0};
|
||||
write_command(0x1A, 0, data, 4, 0);
|
||||
}
|
||||
}
|
||||
|
||||
/*
|
||||
@@ -1105,6 +1119,11 @@ void Boiler::process_UBAMonitorSlowPlus(std::shared_ptr<const Telegram> telegram
|
||||
has_update(telegram, heatStarts_, 22, 3); // force to 3 bytes
|
||||
has_update(telegram, heatingPumpMod_, 25);
|
||||
// temperature measurements at 4, see #620
|
||||
|
||||
if (forceHeatingOff_ == EMS_VALUE_BOOL_ON) {
|
||||
uint8_t data[4] = {0, 0, 0, 0};
|
||||
write_command(0x1A, 0, data, 4, 0);
|
||||
}
|
||||
}
|
||||
|
||||
/*
|
||||
@@ -2576,4 +2595,13 @@ bool Boiler::set_wwAltOpPrio(const char * value, const int8_t id) {
|
||||
return false;
|
||||
}
|
||||
|
||||
bool Boiler::set_forceHeatingOff(const char * value, const int8_t id) {
|
||||
bool v;
|
||||
if (Helpers::value2bool(value, v)) {
|
||||
forceHeatingOff_ = v;
|
||||
return true;
|
||||
}
|
||||
return false;
|
||||
}
|
||||
|
||||
} // namespace emsesp
|
||||
|
||||
@@ -87,7 +87,6 @@ class Boiler : public EMSdevice {
|
||||
uint32_t wwWorkM_; // DHW minutes
|
||||
int8_t wwHystOn_;
|
||||
int8_t wwHystOff_;
|
||||
uint8_t wwTapActivated_; // maintenance-mode to switch DHW off
|
||||
uint16_t wwMixerTemp_; // mixing temperature
|
||||
uint16_t wwCylMiddleTemp_; // Cyl middle temperature (TS3)
|
||||
uint16_t wwSolarTemp_;
|
||||
@@ -95,6 +94,11 @@ class Boiler : public EMSdevice {
|
||||
uint8_t wwAltOpPrioHeat_; // alternating operation, prioritise heat time
|
||||
uint8_t wwAltOpPrioWw_; // alternating operation, prioritise dhw time
|
||||
|
||||
// special function
|
||||
uint8_t forceHeatingOff_;
|
||||
uint8_t wwTapActivated_; // maintenance-mode to switch DHW off
|
||||
|
||||
|
||||
// main
|
||||
uint8_t reset_; // for reset command
|
||||
uint8_t heatingActive_; // Central heating is on/off
|
||||
@@ -447,6 +451,8 @@ class Boiler : public EMSdevice {
|
||||
inline bool set_wwAltOpPrioWw(const char * value, const int8_t id) {
|
||||
return set_wwAltOpPrio(value, 3);
|
||||
}
|
||||
bool set_forceHeatingOff(const char * value, const int8_t id);
|
||||
|
||||
/*
|
||||
bool set_hybridStrategy(const char * value, const int8_t id);
|
||||
bool set_switchOverTemp(const char * value, const int8_t id);
|
||||
|
||||
@@ -269,6 +269,7 @@ MAKE_PSTR_LIST(cyl2, "cyl 2", "Zyl_2", "Cil 2", "Cyl 2", "cyl 2", "cyl 2", "cyl
|
||||
|
||||
// Entity translations
|
||||
// Boiler
|
||||
MAKE_PSTR_LIST(forceHeatingOff, "heatingoff", "force heating off", "Heizen abschalten", "", "", "", "", "")
|
||||
MAKE_PSTR_LIST(wwtapactivated, "wwtapactivated", "turn on/off", "Durchlauferhitzer aktiv", "zet aan/uit", "på/av", "system przygotowywania", "slå på/av", "ecs activée")
|
||||
MAKE_PSTR_LIST(reset, "reset", "Reset", "Reset", "Reset", "Nollställ", "kasowanie komunikatu", "nullstill", "reset")
|
||||
MAKE_PSTR_LIST(oilPreHeat, "oilpreheat", "oil preheating", "Ölvorwärmung", "Olie voorverwarming", "Förvärmning olja", "podgrzewanie oleju", "oljeforvarming", "préchauffage de l'huile")
|
||||
|
||||