mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-08 08:49:52 +03:00
more ems+ optimizations
This commit is contained in:
@@ -41,7 +41,8 @@
|
||||
#define EMS_OFFSET_UBASetPoints_flowtemp 0 // flow temp
|
||||
|
||||
// Other
|
||||
#define EMS_TYPE_SM10Monitor 0x97 // SM10Monitor
|
||||
#define EMS_TYPE_SM10Monitor 0x97 // SM10Monitor
|
||||
#define EMS_TYPE_SM100Monitor 0x0262 // SM100Monitor
|
||||
|
||||
/*
|
||||
* Thermostats...
|
||||
@@ -94,11 +95,11 @@
|
||||
#define EMS_OFFSET_EasyStatusMessage_setpoint 10 // setpoint temp
|
||||
#define EMS_OFFSET_EasyStatusMessage_curr 8 // current temp
|
||||
|
||||
// RC1010 specific
|
||||
#define EMS_TYPE_RC1010StatusMessage 0x01A5 // is an automatic thermostat broadcast giving us temps
|
||||
#define EMS_TYPE_RC1010Set 0x03 // setpoint temp message
|
||||
#define EMS_OFFSET_RC1010StatusMessage_setpoint 3 // setpoint temp
|
||||
#define EMS_OFFSET_RC1010StatusMessage_curr 1 // current temp
|
||||
// RC1010,RC310 and RC300 specific (EMS Plus)
|
||||
#define EMS_TYPE_RCPLUSStatusMessage 0x01A5 // is an automatic thermostat broadcast giving us temps
|
||||
#define EMS_TYPE_RCPLUSSet 0x03 // setpoint temp message - this is incorrect!
|
||||
#define EMS_OFFSET_RCPLUSStatusMessage_setpoint 2 // setpoint temp
|
||||
#define EMS_OFFSET_RCPLUSStatusMessage_curr 0 // current temp
|
||||
|
||||
// Known EMS types
|
||||
typedef enum {
|
||||
@@ -168,17 +169,16 @@ const _Other_Type Other_Types[] = {
|
||||
*/
|
||||
const _Thermostat_Type Thermostat_Types[] = {
|
||||
|
||||
{EMS_MODEL_ES73, 76, 0x10, "Sieger ES73", EMS_THERMOSTAT_READ_YES, EMS_THERMOSTAT_WRITE_YES},
|
||||
{EMS_MODEL_RC10, 79, 0x17, "RC10/Nefit Moduline 100", EMS_THERMOSTAT_READ_YES, EMS_THERMOSTAT_WRITE_YES},
|
||||
{EMS_MODEL_RC20, 77, 0x17, "RC20/Nefit Moduline 300", EMS_THERMOSTAT_READ_YES, EMS_THERMOSTAT_WRITE_YES},
|
||||
{EMS_MODEL_RC20F, 93, 0x18, "RC20F", EMS_THERMOSTAT_READ_YES, EMS_THERMOSTAT_WRITE_YES},
|
||||
{EMS_MODEL_RC30, 78, 0x10, "RC30/Nefit Moduline 400", EMS_THERMOSTAT_READ_YES, EMS_THERMOSTAT_WRITE_YES},
|
||||
{EMS_MODEL_RC35, 86, 0x10, "RC35", EMS_THERMOSTAT_READ_YES, EMS_THERMOSTAT_WRITE_YES},
|
||||
{EMS_MODEL_EASY, 202, 0x18, "TC100/Nefit Easy", EMS_THERMOSTAT_READ_YES, EMS_THERMOSTAT_WRITE_NO},
|
||||
{EMS_MODEL_BOSCHEASY, 206, 0x02, "Bosch Easy", EMS_THERMOSTAT_READ_YES, EMS_THERMOSTAT_WRITE_NO},
|
||||
{EMS_MODEL_RC310, 158, 0x10, "RC310", EMS_THERMOSTAT_READ_NO, EMS_THERMOSTAT_WRITE_NO},
|
||||
{EMS_MODEL_CW100, 255, 0x18, "Bosch CW100", EMS_THERMOSTAT_READ_NO, EMS_THERMOSTAT_WRITE_NO},
|
||||
{EMS_MODEL_CW100, 255, 0x18, "Bosch CW100", EMS_THERMOSTAT_READ_NO, EMS_THERMOSTAT_WRITE_NO},
|
||||
{EMS_MODEL_RC1010, 165, 0x18, "RC1010/Nefit Moduline 1010", EMS_THERMOSTAT_READ_NO, EMS_THERMOSTAT_WRITE_NO}
|
||||
{EMS_MODEL_ES73, 76, 0x10, "Sieger ES73", EMS_THERMOSTAT_WRITE_YES},
|
||||
{EMS_MODEL_RC10, 79, 0x17, "RC10/Nefit Moduline 100", EMS_THERMOSTAT_WRITE_YES},
|
||||
{EMS_MODEL_RC20, 77, 0x17, "RC20/Nefit Moduline 300", EMS_THERMOSTAT_WRITE_YES},
|
||||
{EMS_MODEL_RC20F, 93, 0x18, "RC20F", EMS_THERMOSTAT_WRITE_YES},
|
||||
{EMS_MODEL_RC30, 78, 0x10, "RC30/Nefit Moduline 400", EMS_THERMOSTAT_WRITE_YES},
|
||||
{EMS_MODEL_RC35, 86, 0x10, "RC35", EMS_THERMOSTAT_WRITE_YES},
|
||||
{EMS_MODEL_EASY, 202, 0x18, "TC100/Nefit Easy", EMS_THERMOSTAT_WRITE_NO},
|
||||
{EMS_MODEL_BOSCHEASY, 206, 0x02, "Bosch Easy", EMS_THERMOSTAT_WRITE_NO},
|
||||
{EMS_MODEL_RC310, 158, 0x10, "RC300/RC310", EMS_THERMOSTAT_WRITE_NO},
|
||||
{EMS_MODEL_CW100, 255, 0x18, "Bosch CW100", EMS_THERMOSTAT_WRITE_NO},
|
||||
{EMS_MODEL_RC1010, 165, 0x18, "RC1010/Nefit Moduline 1010", EMS_THERMOSTAT_WRITE_NO}
|
||||
|
||||
};
|
||||
|
||||
Reference in New Issue
Block a user