@@ -113,7 +113,7 @@ static const command_t project_cmds[] PROGMEM = {
|
||||
{false, "queue", "show current Tx queue"},
|
||||
{false, "send XX ...", "send raw telegram data to EMS bus (XX are hex values)"},
|
||||
{false, "thermostat read <type ID>", "send read request to the thermostat for heating circuit hc 1-4"},
|
||||
{false, "thermostat temp <hc> <degrees> [temp]", "set current thermostat temperature. temp=0-6 (see wiki)"},
|
||||
{false, "thermostat temp <degrees> [mode] [hc]", "set current thermostat temperature. mode=0-6 (see wiki), hc=1-4"},
|
||||
{false, "thermostat mode <hc> <mode>", "set mode (0=off, 1=manual, 2=auto) for heating circuit hc 1-4"},
|
||||
{false, "boiler read <type ID>", "send read request to boiler"},
|
||||
{false, "boiler wwtemp <degrees>", "set boiler warm water temperature"},
|
||||
@@ -1602,20 +1602,24 @@ void TelnetCommandCallback(uint8_t wc, const char * commandLine) {
|
||||
}
|
||||
|
||||
// thermostat commands
|
||||
// thermostat temp <tempvalue> <modevalue> <heatingcircuit>
|
||||
if ((strcmp(first_cmd, "thermostat") == 0) && (wc >= 3)) {
|
||||
char * second_cmd = _readWord();
|
||||
|
||||
if (strcmp(second_cmd, "temp") == 0) {
|
||||
uint8_t hc = _readIntNumber(); // next parameter is the heating circuit
|
||||
float temp = _readFloatNumber(); // read in next param which is the temp
|
||||
if (wc == 5) {
|
||||
// we have a temp mode given
|
||||
_THERMOSTAT_TEMP_MODE temp_mode = (_THERMOSTAT_TEMP_MODE)_readIntNumber(); // next parameter is the temp mode type
|
||||
ems_setThermostatTemp(temp, hc, temp_mode);
|
||||
float temp = _readFloatNumber(); // read in next param which is the temp
|
||||
|
||||
if (wc == 3) {
|
||||
// no more params
|
||||
ems_setThermostatTemp(temp, EMS_THERMOSTAT_DEFAULTHC);
|
||||
ok = true;
|
||||
} else {
|
||||
ems_setThermostatTemp(temp, hc);
|
||||
// get modevalue and heatingcircuit
|
||||
_THERMOSTAT_TEMP_MODE temp_mode = (_THERMOSTAT_TEMP_MODE)_readIntNumber(); // next parameter is the temp mode type
|
||||
uint8_t hc = _readIntNumber(); // next parameter is the heating circuit
|
||||
ems_setThermostatTemp(temp, hc, temp_mode);
|
||||
ok = true;
|
||||
}
|
||||
ok = true;
|
||||
} else if (strcmp(second_cmd, "mode") == 0) {
|
||||
uint8_t hc = _readIntNumber(); // next parameter is the heating circuit
|
||||
ems_setThermostatMode(_readIntNumber(), hc);
|
||||
|
||||