@@ -266,8 +266,9 @@ bool ems_getHeatPumpEnabled() {
|
||||
return (EMS_HeatPump.device_id != EMS_ID_NONE);
|
||||
}
|
||||
|
||||
// thermostat has already the 7th bit (to indicate write) stripped
|
||||
uint8_t ems_getThermostatFlags() {
|
||||
return (EMS_Thermostat.device_flags & 0x7F); // strip 7th bit which is used to show whether Write is supported
|
||||
return (EMS_Thermostat.device_flags);
|
||||
}
|
||||
|
||||
uint8_t ems_getSolarModuleFlags() {
|
||||
@@ -1840,6 +1841,15 @@ void _process_Version(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
brand = 0; // unknown
|
||||
}
|
||||
|
||||
/*
|
||||
// override to emulate other thermostats - FR100
|
||||
if (device_id == 0x17) {
|
||||
brand = 2;
|
||||
device_id = 0x10;
|
||||
product_id = 107;
|
||||
}
|
||||
*/
|
||||
|
||||
// first scan through matching boilers, as these are unique to DeviceID 0x08
|
||||
uint8_t i = 0;
|
||||
while (i < _EMS_Devices_max) {
|
||||
@@ -2451,16 +2461,14 @@ void ems_setThermostatTemp(float temperature, uint8_t hc_num, _THERMOSTAT_TEMP_M
|
||||
EMS_TxTelegram.type_validate = EMS_TxTelegram.type;
|
||||
}
|
||||
|
||||
else if (model == EMS_DEVICE_FLAG_JUNKERS) {
|
||||
else if (model & EMS_DEVICE_FLAG_JUNKERS) {
|
||||
EMS_TxTelegram.emsplus = true; // Assuming here that all Junkers use EMS+
|
||||
|
||||
// figure out if we have older or new thermostats
|
||||
// Heating Circuits on 0x65 or 0x79 (see https://github.com/proddy/EMS-ESP/issues/335#issuecomment-593324716)
|
||||
// strip 7th (write) and 6th (junkers) bits to leave EMS_DEVICE_FLAG_JUNKERS_CONFIG1 or CONFIG2
|
||||
bool newer_junkers = ((model & 0x3F) == EMS_DEVICE_FLAG_JUNKERS_CONFIG1);
|
||||
|
||||
if (newer_junkers) {
|
||||
// new models like the FW series
|
||||
// Heating Circuits on 0x65 (EMS_DEVICE_FLAG_JUNKERS_CONFIG1) or 0x79 (EMS_DEVICE_FLAG_JUNKERS_CONFIG2)
|
||||
// see https://github.com/proddy/EMS-ESP/issues/335#issuecomment-593324716)
|
||||
if ((model & 0x3F) == EMS_DEVICE_FLAG_JUNKERS_CONFIG1) {
|
||||
// EMS_DEVICE_FLAG_JUNKERS_CONFIG1 - new models like the FW series
|
||||
switch (temptype) {
|
||||
case THERMOSTAT_TEMP_MODE_NOFROST:
|
||||
EMS_TxTelegram.offset = EMS_OFFSET_JunkersSetMessage_no_frost_temp;
|
||||
@@ -2483,6 +2491,7 @@ void ems_setThermostatTemp(float temperature, uint8_t hc_num, _THERMOSTAT_TEMP_M
|
||||
EMS_TxTelegram.type = EMS_TYPE_JunkersSetMessage1_HC1 + hc_num - 1; // 0x65
|
||||
EMS_TxTelegram.comparisonPostRead = EMS_TYPE_JunkersStatusMessage_HC1 + hc_num - 1;
|
||||
} else {
|
||||
// EMS_DEVICE_FLAG_JUNKERS_CONFIG2
|
||||
switch (temptype) {
|
||||
case THERMOSTAT_TEMP_MODE_NOFROST:
|
||||
EMS_TxTelegram.offset = EMS_OFFSET_JunkersSetMessage2_no_frost_temp;
|
||||
|
||||
Reference in New Issue