mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-07 16:29:51 +03:00
Render values in Web natively #70
This commit is contained in:
@@ -86,7 +86,7 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
|
||||
}
|
||||
// MQTT commands for boiler topic
|
||||
register_device_value(
|
||||
TAG_BOILER_DATA, &dummybool_, DeviceValueType::BOOL, nullptr, FL_(wwtapactivated), DeviceValueUOM::NONE, MAKE_CF_CB(set_tapwarmwater_activated));
|
||||
TAG_BOILER_DATA, &dummybool_, DeviceValueType::BOOL, nullptr, FL_(wwtapactivated), DeviceValueUOM::BOOLEAN, MAKE_CF_CB(set_tapwarmwater_activated));
|
||||
register_device_value(TAG_BOILER_DATA, &dummy8u_, DeviceValueType::ENUM, FL_(enum_reset), FL_(reset), DeviceValueUOM::NONE, MAKE_CF_CB(set_reset));
|
||||
|
||||
// add values
|
||||
@@ -96,8 +96,8 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
|
||||
register_device_value(TAG_BOILER_DATA, &id_, DeviceValueType::UINT, nullptr, FL_(ID), DeviceValueUOM::NONE);
|
||||
id_ = product_id;
|
||||
|
||||
register_device_value(TAG_BOILER_DATA, &heatingActive_, DeviceValueType::BOOL, nullptr, FL_(heatingActive), DeviceValueUOM::NONE);
|
||||
register_device_value(TAG_BOILER_DATA, &tapwaterActive_, DeviceValueType::BOOL, nullptr, FL_(tapwaterActive), DeviceValueUOM::NONE);
|
||||
register_device_value(TAG_BOILER_DATA, &heatingActive_, DeviceValueType::BOOL, nullptr, FL_(heatingActive), DeviceValueUOM::BOOLEAN);
|
||||
register_device_value(TAG_BOILER_DATA, &tapwaterActive_, DeviceValueType::BOOL, nullptr, FL_(tapwaterActive), DeviceValueUOM::BOOLEAN);
|
||||
register_device_value(TAG_BOILER_DATA, &selFlowTemp_, DeviceValueType::UINT, nullptr, FL_(selFlowTemp), DeviceValueUOM::DEGREES, MAKE_CF_CB(set_flow_temp));
|
||||
register_device_value(TAG_BOILER_DATA, &selBurnPow_, DeviceValueType::UINT, nullptr, FL_(selBurnPow), DeviceValueUOM::PERCENT, MAKE_CF_CB(set_burn_power));
|
||||
register_device_value(TAG_BOILER_DATA, &heatingPumpMod_, DeviceValueType::UINT, nullptr, FL_(heatingPumpMod), DeviceValueUOM::PERCENT);
|
||||
@@ -109,13 +109,13 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
|
||||
register_device_value(TAG_BOILER_DATA, &sysPress_, DeviceValueType::UINT, FL_(div10), FL_(sysPress), DeviceValueUOM::BAR);
|
||||
register_device_value(TAG_BOILER_DATA, &boilTemp_, DeviceValueType::USHORT, FL_(div10), FL_(boilTemp), DeviceValueUOM::DEGREES);
|
||||
register_device_value(TAG_BOILER_DATA, &exhaustTemp_, DeviceValueType::USHORT, FL_(div10), FL_(exhaustTemp), DeviceValueUOM::DEGREES);
|
||||
register_device_value(TAG_BOILER_DATA, &burnGas_, DeviceValueType::BOOL, nullptr, FL_(burnGas), DeviceValueUOM::NONE);
|
||||
register_device_value(TAG_BOILER_DATA, &burnGas_, DeviceValueType::BOOL, nullptr, FL_(burnGas), DeviceValueUOM::BOOLEAN);
|
||||
register_device_value(TAG_BOILER_DATA, &flameCurr_, DeviceValueType::USHORT, FL_(div10), FL_(flameCurr), DeviceValueUOM::UA);
|
||||
register_device_value(TAG_BOILER_DATA, &heatingPump_, DeviceValueType::BOOL, nullptr, FL_(heatingPump), DeviceValueUOM::NONE);
|
||||
register_device_value(TAG_BOILER_DATA, &fanWork_, DeviceValueType::BOOL, nullptr, FL_(fanWork), DeviceValueUOM::NONE);
|
||||
register_device_value(TAG_BOILER_DATA, &ignWork_, DeviceValueType::BOOL, nullptr, FL_(ignWork), DeviceValueUOM::NONE);
|
||||
register_device_value(TAG_BOILER_DATA, &heatingPump_, DeviceValueType::BOOL, nullptr, FL_(heatingPump), DeviceValueUOM::BOOLEAN);
|
||||
register_device_value(TAG_BOILER_DATA, &fanWork_, DeviceValueType::BOOL, nullptr, FL_(fanWork), DeviceValueUOM::BOOLEAN);
|
||||
register_device_value(TAG_BOILER_DATA, &ignWork_, DeviceValueType::BOOL, nullptr, FL_(ignWork), DeviceValueUOM::BOOLEAN);
|
||||
register_device_value(
|
||||
TAG_BOILER_DATA, &heatingActivated_, DeviceValueType::BOOL, nullptr, FL_(heatingActivated), DeviceValueUOM::NONE, MAKE_CF_CB(set_heating_activated));
|
||||
TAG_BOILER_DATA, &heatingActivated_, DeviceValueType::BOOL, nullptr, FL_(heatingActivated), DeviceValueUOM::BOOLEAN, MAKE_CF_CB(set_heating_activated));
|
||||
register_device_value(TAG_BOILER_DATA, &heatingTemp_, DeviceValueType::UINT, nullptr, FL_(heatingTemp), DeviceValueUOM::DEGREES, MAKE_CF_CB(set_heating_temp));
|
||||
register_device_value(TAG_BOILER_DATA, &pumpModMax_, DeviceValueType::UINT, nullptr, FL_(pumpModMax), DeviceValueUOM::PERCENT, MAKE_CF_CB(set_max_pump));
|
||||
register_device_value(TAG_BOILER_DATA, &pumpModMin_, DeviceValueType::UINT, nullptr, FL_(pumpModMin), DeviceValueUOM::PERCENT, MAKE_CF_CB(set_min_pump));
|
||||
@@ -190,8 +190,8 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
|
||||
register_device_value(
|
||||
TAG_DEVICE_DATA_WW, &wWMaxPower_, DeviceValueType::UINT, nullptr, FL_(wWMaxPower), DeviceValueUOM::PERCENT, MAKE_CF_CB(set_warmwater_maxpower));
|
||||
register_device_value(
|
||||
TAG_DEVICE_DATA_WW, &wWCircPump_, DeviceValueType::BOOL, nullptr, FL_(wWCircPump), DeviceValueUOM::NONE, MAKE_CF_CB(set_warmwater_circulation_pump));
|
||||
register_device_value(TAG_DEVICE_DATA_WW, &wWChargeType_, DeviceValueType::BOOL, FL_(enum_charge), FL_(wWChargeType), DeviceValueUOM::NONE);
|
||||
TAG_DEVICE_DATA_WW, &wWCircPump_, DeviceValueType::BOOL, nullptr, FL_(wWCircPump), DeviceValueUOM::BOOLEAN, MAKE_CF_CB(set_warmwater_circulation_pump));
|
||||
register_device_value(TAG_DEVICE_DATA_WW, &wWChargeType_, DeviceValueType::ENUM, FL_(enum_charge), FL_(wWChargeType), DeviceValueUOM::NONE);
|
||||
register_device_value(TAG_DEVICE_DATA_WW,
|
||||
&wWDisinfectionTemp_,
|
||||
DeviceValueType::UINT,
|
||||
@@ -206,21 +206,21 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
|
||||
FL_(wWCircMode),
|
||||
DeviceValueUOM::NONE,
|
||||
MAKE_CF_CB(set_warmwater_circulation_mode));
|
||||
register_device_value(TAG_DEVICE_DATA_WW, &wWCirc_, DeviceValueType::BOOL, nullptr, FL_(wWCirc), DeviceValueUOM::NONE, MAKE_CF_CB(set_warmwater_circulation));
|
||||
register_device_value(TAG_DEVICE_DATA_WW, &wWCirc_, DeviceValueType::BOOL, nullptr, FL_(wWCirc), DeviceValueUOM::BOOLEAN, MAKE_CF_CB(set_warmwater_circulation));
|
||||
register_device_value(TAG_DEVICE_DATA_WW, &wWCurTemp_, DeviceValueType::USHORT, FL_(div10), FL_(wWCurTemp), DeviceValueUOM::DEGREES);
|
||||
register_device_value(TAG_DEVICE_DATA_WW, &wWCurTemp2_, DeviceValueType::USHORT, FL_(div10), FL_(wWCurTemp2), DeviceValueUOM::DEGREES);
|
||||
register_device_value(TAG_DEVICE_DATA_WW, &wWCurFlow_, DeviceValueType::UINT, FL_(div10), FL_(wWCurFlow), DeviceValueUOM::LMIN);
|
||||
register_device_value(TAG_DEVICE_DATA_WW, &wWStorageTemp1_, DeviceValueType::USHORT, FL_(div10), FL_(wWStorageTemp1), DeviceValueUOM::DEGREES);
|
||||
register_device_value(TAG_DEVICE_DATA_WW, &wWStorageTemp2_, DeviceValueType::USHORT, FL_(div10), FL_(wWStorageTemp2), DeviceValueUOM::DEGREES);
|
||||
register_device_value(
|
||||
TAG_DEVICE_DATA_WW, &wWActivated_, DeviceValueType::BOOL, nullptr, FL_(wWActivated), DeviceValueUOM::NONE, MAKE_CF_CB(set_warmwater_activated));
|
||||
register_device_value(TAG_DEVICE_DATA_WW, &wWOneTime_, DeviceValueType::BOOL, nullptr, FL_(wWOneTime), DeviceValueUOM::NONE, MAKE_CF_CB(set_warmwater_onetime));
|
||||
register_device_value(TAG_DEVICE_DATA_WW, &wWDisinfecting_, DeviceValueType::BOOL, nullptr, FL_(wWDisinfecting), DeviceValueUOM::NONE);
|
||||
register_device_value(TAG_DEVICE_DATA_WW, &wWCharging_, DeviceValueType::BOOL, nullptr, FL_(wWCharging), DeviceValueUOM::NONE);
|
||||
register_device_value(TAG_DEVICE_DATA_WW, &wWRecharging_, DeviceValueType::BOOL, nullptr, FL_(wWRecharging), DeviceValueUOM::NONE);
|
||||
register_device_value(TAG_DEVICE_DATA_WW, &wWTempOK_, DeviceValueType::BOOL, nullptr, FL_(wWTempOK), DeviceValueUOM::NONE);
|
||||
register_device_value(TAG_DEVICE_DATA_WW, &wWActive_, DeviceValueType::BOOL, nullptr, FL_(wWActive), DeviceValueUOM::NONE);
|
||||
register_device_value(TAG_DEVICE_DATA_WW, &wWHeat_, DeviceValueType::BOOL, nullptr, FL_(wWHeat), DeviceValueUOM::NONE);
|
||||
TAG_DEVICE_DATA_WW, &wWActivated_, DeviceValueType::BOOL, nullptr, FL_(wWActivated), DeviceValueUOM::BOOLEAN, MAKE_CF_CB(set_warmwater_activated));
|
||||
register_device_value(TAG_DEVICE_DATA_WW, &wWOneTime_, DeviceValueType::BOOL, nullptr, FL_(wWOneTime), DeviceValueUOM::BOOLEAN, MAKE_CF_CB(set_warmwater_onetime));
|
||||
register_device_value(TAG_DEVICE_DATA_WW, &wWDisinfecting_, DeviceValueType::BOOL, nullptr, FL_(wWDisinfecting), DeviceValueUOM::BOOLEAN);
|
||||
register_device_value(TAG_DEVICE_DATA_WW, &wWCharging_, DeviceValueType::BOOL, nullptr, FL_(wWCharging), DeviceValueUOM::BOOLEAN);
|
||||
register_device_value(TAG_DEVICE_DATA_WW, &wWRecharging_, DeviceValueType::BOOL, nullptr, FL_(wWRecharging), DeviceValueUOM::BOOLEAN);
|
||||
register_device_value(TAG_DEVICE_DATA_WW, &wWTempOK_, DeviceValueType::BOOL, nullptr, FL_(wWTempOK), DeviceValueUOM::BOOLEAN);
|
||||
register_device_value(TAG_DEVICE_DATA_WW, &wWActive_, DeviceValueType::BOOL, nullptr, FL_(wWActive), DeviceValueUOM::BOOLEAN);
|
||||
register_device_value(TAG_DEVICE_DATA_WW, &wWHeat_, DeviceValueType::BOOL, nullptr, FL_(wWHeat), DeviceValueUOM::BOOLEAN);
|
||||
register_device_value(TAG_DEVICE_DATA_WW, &wWSetPumpPower_, DeviceValueType::UINT, nullptr, FL_(wWSetPumpPower), DeviceValueUOM::PERCENT);
|
||||
register_device_value(TAG_DEVICE_DATA_WW, &mixerTemp_, DeviceValueType::USHORT, FL_(div10), FL_(mixerTemp), DeviceValueUOM::DEGREES);
|
||||
register_device_value(TAG_DEVICE_DATA_WW, &tankMiddleTemp_, DeviceValueType::USHORT, FL_(div10), FL_(tankMiddleTemp), DeviceValueUOM::DEGREES);
|
||||
@@ -311,7 +311,6 @@ void Boiler::check_active(const bool force) {
|
||||
}
|
||||
|
||||
// 0x33
|
||||
// Boiler(0x08) -> Me(0x0B), UBAParameterWW(0x33), data: 08 FF 30 FB FF 28 FF 07 46 00 00
|
||||
void Boiler::process_UBAParameterWW(std::shared_ptr<const Telegram> telegram) {
|
||||
// has_update(telegram->read_bitvalue(wwEquipt_,0,3)); // 8=boiler has ww
|
||||
has_update(telegram->read_value(wWActivated_, 1)); // 0xFF means on
|
||||
@@ -322,8 +321,7 @@ void Boiler::process_UBAParameterWW(std::shared_ptr<const Telegram> telegram) {
|
||||
has_update(telegram->read_value(wWCircPump_, 6)); // 0xFF means on
|
||||
has_update(telegram->read_value(wWCircMode_, 7)); // 1=1x3min 6=6x3min 7=continuous
|
||||
has_update(telegram->read_value(wWDisinfectionTemp_, 8));
|
||||
has_update(telegram->read_value(wWChargeType_,
|
||||
10)); // 0 = charge pump, 0xff = 3-way valve
|
||||
has_update(telegram->read_bitvalue(wWChargeType_, 10, 0)); // 0 = charge pump, 0xff = 3-way valve
|
||||
|
||||
telegram->read_value(wWComfort_, 9);
|
||||
if (wWComfort_ == 0x00) {
|
||||
@@ -1175,7 +1173,7 @@ bool Boiler::set_warmwater_circulation_pump(const char * value, const int8_t id)
|
||||
return true;
|
||||
}
|
||||
|
||||
// Set the mode of circulation, 1x3min, ... 6x3min, continuos
|
||||
// Set the mode of circulation, 1x3min, ... 6x3min, continuous
|
||||
// true = on, false = off
|
||||
bool Boiler::set_warmwater_circulation_mode(const char * value, const int8_t id) {
|
||||
int v = 0;
|
||||
@@ -1187,7 +1185,7 @@ bool Boiler::set_warmwater_circulation_mode(const char * value, const int8_t id)
|
||||
if (v < 7) {
|
||||
LOG_INFO(F("Setting warm water circulation mode %dx3min"), v);
|
||||
} else if (v == 7) {
|
||||
LOG_INFO(F("Setting warm water circulation mode continuos"));
|
||||
LOG_INFO(F("Setting warm water circulation mode continuous"));
|
||||
} else {
|
||||
LOG_WARNING(F("Set warm water circulation mode: Invalid value"));
|
||||
return false;
|
||||
|
||||
Reference in New Issue