don't show AM200 valves with unknown offset
This commit is contained in:
@@ -1152,9 +1152,11 @@ void Boiler::process_UBAMaintenanceData(std::shared_ptr<const Telegram> telegram
|
||||
has_update(maintenanceDate_, date, sizeof(maintenanceDate_));
|
||||
}
|
||||
}
|
||||
|
||||
/*
|
||||
* alternative heatingsource AM200
|
||||
*/
|
||||
// 0x054D AM200 temperatures
|
||||
// Rx: 60 00 FF 00 04 4D 0103 0108 8000 00C6 0127 0205 8000 0200 0000 8000 6C
|
||||
// TB4 TR2 TA1 TR1 TB1 TB2* TB3
|
||||
void Boiler::process_amTempMessage(std::shared_ptr<const Telegram> telegram) {
|
||||
@@ -1167,17 +1169,24 @@ void Boiler::process_amTempMessage(std::shared_ptr<const Telegram> telegram) {
|
||||
has_update(telegram, cylBottomTemp_, 14);
|
||||
}
|
||||
|
||||
// 0x054E AM200 status (6 bytes long)
|
||||
// Rx: 60 00 FF 00 04 4E 00 00 00 00 00 00 86
|
||||
void Boiler::process_amStatusMessage(std::shared_ptr<const Telegram> telegram) {
|
||||
has_update(telegram, aPump_, 0);
|
||||
has_update(telegram, valveByPass_, 1);
|
||||
has_update(telegram, valveBuffer_, 2);
|
||||
has_update(telegram, valveReturn_, 3);
|
||||
// actually we dont know the offset of the valves
|
||||
// has_update(telegram, valveByPass_, 1);
|
||||
// has_update(telegram, valveBuffer_, 2);
|
||||
// has_update(telegram, valveReturn_, 3);
|
||||
}
|
||||
|
||||
// 0x0550 AM200 broadcasted message, all 27 bytes unkown
|
||||
// Rx: 60 00 FF 00 04 50 00 FF 00 FF FF 00 0D 00 01 00 00 00 00 01 03 01 00 03 00 2D 19 C8 02 94 00 4A
|
||||
// Rx: 60 00 FF 19 04 50 00 FF FF 39
|
||||
void Boiler::process_amSettingMessage(std::shared_ptr<const Telegram> telegram) {
|
||||
// has_update(telegram, setRetTemp_, 0);
|
||||
// has_update(telegram, setFlowTemp_, 1);
|
||||
// has_update(telegram, setRetTemp_, ?);
|
||||
// has_update(telegram, setFlowTemp_, ?);
|
||||
}
|
||||
|
||||
/*
|
||||
* Hybrid heatpump with telegram 0xBB is readable and writeable in boiler and thermostat
|
||||
* thermostat always overwrites settings in boiler
|
||||
|
||||
Reference in New Issue