@@ -393,13 +393,29 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
|
||||
FL_(wwComfort),
|
||||
DeviceValueUOM::NONE,
|
||||
MAKE_CF_CB(set_ww_mode));
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA_WW,
|
||||
&wwComfort1_,
|
||||
DeviceValueType::ENUM,
|
||||
FL_(enum_comfort1),
|
||||
FL_(wwComfort1),
|
||||
DeviceValueUOM::NONE,
|
||||
MAKE_CF_CB(set_ww_mode1));
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA_WW,
|
||||
&wwFlowTempOffset_,
|
||||
DeviceValueType::UINT,
|
||||
nullptr,
|
||||
FL_(wwFlowTempOffset),
|
||||
DeviceValueUOM::DEGREES_R,
|
||||
MAKE_CF_CB(set_ww_flowTempOffset));
|
||||
MAKE_CF_CB(set_ww_flowTempOffset),
|
||||
0,
|
||||
40);
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA_WW,
|
||||
&wwChargeOptimization_,
|
||||
DeviceValueType::BOOL,
|
||||
nullptr,
|
||||
FL_(wwChargeOptimization),
|
||||
DeviceValueUOM::NONE,
|
||||
MAKE_CF_CB(set_ww_chargeOptimization));
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA_WW,
|
||||
&wwMaxPower_,
|
||||
DeviceValueType::UINT,
|
||||
@@ -773,11 +789,26 @@ void Boiler::process_UBAParameterWWPlus(std::shared_ptr<const Telegram> telegram
|
||||
has_update(telegram, wwSelTemp_, 6); // setting here
|
||||
has_update(telegram, wwHystOn_, 7);
|
||||
has_update(telegram, wwHystOff_, 8);
|
||||
has_update(telegram, wwFlowTempOffset_, 9);
|
||||
has_update(telegram, wwCircPump_, 10); // 0x01 means yes
|
||||
has_update(telegram, wwCircMode_, 11); // 1=1x3min... 6=6x3min, 7=continuous
|
||||
has_update(telegram, wwDisinfectionTemp_, 12); // setting here, status in E9
|
||||
has_update(telegram, wwSelTempSingle_, 16);
|
||||
has_update(telegram, wwSelTempLow_, 18);
|
||||
has_update(telegram, wwChargeOptimization_, 25);
|
||||
|
||||
uint8_t wwComfort1 = EMS_VALUE_UINT_NOTSET;
|
||||
telegram->read_value(wwComfort1, 13);
|
||||
if (wwComfort1 == 0) {
|
||||
wwComfort1 = 0; // High_Comfort
|
||||
} else if (wwComfort1 == 0xD8) {
|
||||
wwComfort1 = 1; // Eco
|
||||
} else {
|
||||
wwComfort1 = EMS_VALUE_UINT_NOTSET;
|
||||
}
|
||||
has_update(wwComfort1_, wwComfort1);
|
||||
|
||||
|
||||
}
|
||||
|
||||
// 0xE9 - WW monitor ems+
|
||||
@@ -1249,7 +1280,11 @@ bool Boiler::set_ww_flowTempOffset(const char * value, const int8_t id) {
|
||||
return false;
|
||||
}
|
||||
|
||||
write_command(EMS_TYPE_UBAParameterWW, 5, v, EMS_TYPE_UBAParameterWW);
|
||||
if (is_fetch(EMS_TYPE_UBAParameterWWPlus)) {
|
||||
write_command(EMS_TYPE_UBAParameterWWPlus, 9, v, EMS_TYPE_UBAParameterWWPlus);
|
||||
} else {
|
||||
write_command(EMS_TYPE_UBAParameterWW, 5, v, EMS_TYPE_UBAParameterWW);
|
||||
}
|
||||
|
||||
return true;
|
||||
}
|
||||
@@ -1350,6 +1385,23 @@ bool Boiler::set_ww_hyst_off(const char * value, const int8_t id) {
|
||||
return true;
|
||||
}
|
||||
|
||||
// set ww charge optimization
|
||||
bool Boiler::set_ww_chargeOptimization(const char * value, const int8_t id) {
|
||||
bool v = false;
|
||||
if (!Helpers::value2bool(value, v)) {
|
||||
return false;
|
||||
}
|
||||
|
||||
if (is_fetch(EMS_TYPE_UBAParameterWWPlus)) {
|
||||
write_command(EMS_TYPE_UBAParameterWWPlus, 25, v ? 1 : 0, EMS_TYPE_UBAParameterWWPlus);
|
||||
}
|
||||
|
||||
return true;
|
||||
}
|
||||
|
||||
|
||||
|
||||
|
||||
// set dhw max power
|
||||
bool Boiler::set_ww_maxpower(const char * value, const int8_t id) {
|
||||
int v = 0;
|
||||
@@ -1485,6 +1537,31 @@ bool Boiler::set_ww_mode(const char * value, const int8_t id) {
|
||||
return true;
|
||||
}
|
||||
|
||||
// wwcomfort1 for RC310
|
||||
// on a RC310 it's 1=high, 2=eco
|
||||
bool Boiler::set_ww_mode1(const char * value, const int8_t id) {
|
||||
uint8_t set;
|
||||
if (!Helpers::value2enum(value, set, FL_(enum_comfort1))) {
|
||||
return false;
|
||||
}
|
||||
|
||||
if (!is_fetch(EMS_TYPE_UBAParameterWWPlus)) {
|
||||
return false;
|
||||
}
|
||||
|
||||
if (set == 0) {
|
||||
// LOG_INFO(F("Setting boiler dhw to High"));
|
||||
} else if (set == 1) {
|
||||
// LOG_INFO(F("Setting boiler dhw to Eco"));
|
||||
set = 0xD8;
|
||||
} else {
|
||||
return false; // do nothing
|
||||
}
|
||||
|
||||
write_command(EMS_TYPE_UBAParameterWWPlus, 13, set, EMS_TYPE_UBAParameterWWPlus);
|
||||
return true;
|
||||
}
|
||||
|
||||
// turn on/off dhw
|
||||
bool Boiler::set_ww_activated(const char * value, const int8_t id) {
|
||||
bool v = false;
|
||||
|
||||
Reference in New Issue