mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-08 00:39:50 +03:00
mention breaking changes to building the web files
This commit is contained in:
19
CHANGELOG.md
19
CHANGELOG.md
@@ -7,26 +7,31 @@ and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0
|
|||||||
|
|
||||||
## [1.9.2 beta]
|
## [1.9.2 beta]
|
||||||
|
|
||||||
Important! This build has breaking changes:
|
#### Important! This build has breaking changes:
|
||||||
- the MQTT `thermostat_data` topic is always suffixed with the heat countroller number, e.g. `thermostat_data1`
|
- the Thermostat MQTT topics are all always suffixed with the heat controller number, e.g. `thermostat_data1`
|
||||||
- the web builder has been upgraded to use gulp 4. Delete the `tools/webfilesbuilder/node_modules` and re-install the libraries using `npm i` from within the `tools/webfilesbuilder` folder.
|
- the web builder has been upgraded to use Gulp 4. Remove `tools/webfilesbuilder/node_modules` and re-install the libraries using `npm i` from within the `tools/webfilesbuilder` folder.
|
||||||
|
|
||||||
### Added
|
### Added
|
||||||
|
|
||||||
- Handling of MM100 Status Messages (thanks @kstaniek)
|
- Handling of MM100 Status Messages (thanks @kstaniek)
|
||||||
- retrieve/display mode for Junkers FW100/120 thermostats (thanks @Neonox31)
|
- Retrieve/display mode for Junkers FW100/120 thermostats (thanks @Neonox31)
|
||||||
|
- Added error fall-back for MQTT publishes that fail
|
||||||
|
|
||||||
### Fixed
|
### Fixed
|
||||||
|
|
||||||
- `publish` command also sends Dallas external temperature sensor values
|
- `publish` command also sends Dallas external temperature sensor values
|
||||||
|
- `log_events` setting wasn't persisted in config file
|
||||||
|
|
||||||
### Changed
|
### Changed
|
||||||
|
|
||||||
- External dallas sensor values sent in MQTT payload as float values and not strings
|
- External dallas sensor values sent in MQTT payload as float values and not strings
|
||||||
- Breaking change! all MQTT topics for the Thermostat have the Heating Circuit appended (e.g. `thermostat_data1`)
|
- All MQTT topics for the Thermostat have the Heating Circuit appended (e.g. `thermostat_data1`). This includes the commands.
|
||||||
- Breaking change! Removed the heatingcircuit from the MQTT Thermostat topic payload
|
- Shower timer and shower alert and not MQTT published at boot up
|
||||||
|
|
||||||
|
### Removed
|
||||||
|
|
||||||
|
- Removed telnet command `shower timer` and `shower alert` to toggle the switches
|
||||||
|
- Removed the heatingcircuit key/value from the MQTT Thermostat topic payload
|
||||||
|
|
||||||
## [1.9.1] 2019-10-05
|
## [1.9.1] 2019-10-05
|
||||||
|
|
||||||
|
|||||||
Reference in New Issue
Block a user