fix RC300 offsettemp, minexttemp #599

This commit is contained in:
MichaelDvP
2020-11-20 10:47:17 +01:00
parent 280f4e5099
commit 93bc5c2793

View File

@@ -1624,7 +1624,11 @@ bool Thermostat::set_minexttemp(const char * value, const int8_t id) {
}
LOG_INFO(F("Setting min external temperature to %d"), mt);
if ((this->model() == EMS_DEVICE_FLAG_RC300) || (this->model() == EMS_DEVICE_FLAG_RC100)) {
write_command(0x240, 10, mt, 0x240);
} else {
write_command(EMS_TYPE_IBASettings, 5, mt, EMS_TYPE_IBASettings);
}
return true;
}
@@ -2204,6 +2208,7 @@ bool Thermostat::set_temperature(const float temperature, const uint8_t mode, co
offset = 2;
set_typeid = summer_typeids[hc->hc_num() - 1];
validate_typeid = set_typeid;
factor = 1;
break;
case HeatingCircuit::Mode::DESIGN:
set_typeid = summer_typeids[hc->hc_num() - 1];