MM100 EMS_TYPE_MMPLUSStatusMessage added
This commit is contained in:
62
src/ems.cpp
62
src/ems.cpp
@@ -99,6 +99,9 @@ void _process_RCPLUSStatusMode(_EMS_RxTelegram * EMS_RxTelegram);
|
||||
// Junkers FR10 & FW100
|
||||
void _process_JunkersStatusMessage(_EMS_RxTelegram * EMS_RxTelegram);
|
||||
|
||||
// Mixers MM100
|
||||
void _process_MMPLUSStatusMessage(_EMS_RxTelegram * EMS_RxTelegram);
|
||||
|
||||
/**
|
||||
* Recognized EMS types and the functions they call to process the telegrams
|
||||
* Format: MODEL ID, TYPE ID, Description, function, emsplus
|
||||
@@ -184,8 +187,11 @@ const _EMS_Type EMS_Types[] = {
|
||||
{EMS_MODEL_ALL, EMS_TYPE_RCPLUSStatusMode, "RCPLUSStatusMode", _process_RCPLUSStatusMode},
|
||||
|
||||
// Junkers FR10
|
||||
{EMS_MODEL_ALL, EMS_TYPE_JunkersStatusMessage, "JunkersStatusMessage", _process_JunkersStatusMessage}
|
||||
{EMS_MODEL_ALL, EMS_TYPE_JunkersStatusMessage, "JunkersStatusMessage", _process_JunkersStatusMessage},
|
||||
|
||||
// Mixing devices
|
||||
{EMS_MODEL_MM100, EMS_TYPE_MMPLUSStatusMessage_HC1, "MMPLUSStatusMessage_HC1", _process_MMPLUSStatusMessage},
|
||||
{EMS_MODEL_MM100, EMS_TYPE_MMPLUSStatusMessage_HC2, "MMPLUSStatusMessage_HC2", _process_MMPLUSStatusMessage},
|
||||
|
||||
};
|
||||
|
||||
@@ -196,13 +202,15 @@ uint8_t _SolarModule_Devices_max = ArraySize(SolarModule_Devices); // number of
|
||||
uint8_t _Other_Devices_max = ArraySize(Other_Devices); // number of other ems devices
|
||||
uint8_t _Thermostat_Devices_max = ArraySize(Thermostat_Devices); // number of defined thermostat types
|
||||
uint8_t _HeatPump_Devices_max = ArraySize(HeatPump_Devices); // number of defined heatpump types
|
||||
uint8_t _Mixing_Devices_max = ArraySize(Mixing_Devices); // number of mixing device types
|
||||
|
||||
// these structs contain the data we store from the specific EMS devices
|
||||
_EMS_Boiler EMS_Boiler; // for boiler
|
||||
_EMS_Thermostat EMS_Thermostat; // for thermostat
|
||||
_EMS_SolarModule EMS_SolarModule; // for solar modules
|
||||
_EMS_HeatPump EMS_HeatPump; // for heatpumps
|
||||
_EMS_Other EMS_Other; // for other known EMS devices
|
||||
_EMS_Mixing EMS_Mixing; // for mixing devices
|
||||
_EMS_Other EMS_Other; // for other known EMS devices
|
||||
|
||||
// CRC lookup table with poly 12 for faster checking
|
||||
const uint8_t ems_crc_table[] = {0x00, 0x02, 0x04, 0x06, 0x08, 0x0A, 0x0C, 0x0E, 0x10, 0x12, 0x14, 0x16, 0x18, 0x1A, 0x1C, 0x1E, 0x20, 0x22, 0x24, 0x26,
|
||||
@@ -267,6 +275,16 @@ void ems_init() {
|
||||
EMS_Thermostat.hc[i].curr_roomTemp = EMS_VALUE_SHORT_NOTSET;
|
||||
}
|
||||
|
||||
EMS_Mixing.detected = false;
|
||||
// init all mixing modules
|
||||
for (uint8_t i = 0; i < EMS_THERMOSTAT_MAXHC; i++) {
|
||||
EMS_Mixing.hc[i].hc = i + 1;
|
||||
EMS_Mixing.hc[i].flowTemp = EMS_VALUE_SHORT_NOTSET;
|
||||
EMS_Mixing.hc[i].device_id = EMS_ID_NONE;
|
||||
EMS_Mixing.hc[i].model_id = EMS_MODEL_NONE;
|
||||
EMS_Mixing.hc[i].product_id = EMS_ID_NONE;
|
||||
}
|
||||
|
||||
// UBAParameterWW
|
||||
EMS_Boiler.wWActivated = EMS_VALUE_INT_NOTSET; // Warm Water activated
|
||||
EMS_Boiler.wWSelTemp = EMS_VALUE_INT_NOTSET; // Warm Water selected temperature
|
||||
@@ -378,6 +396,10 @@ bool ems_getThermostatEnabled() {
|
||||
return (EMS_Thermostat.device_id != EMS_ID_NONE);
|
||||
}
|
||||
|
||||
bool ems_getMixingDeviceEnabled() {
|
||||
return EMS_Mixing.detected;
|
||||
}
|
||||
|
||||
bool ems_getSolarModuleEnabled() {
|
||||
return (EMS_SolarModule.device_id != EMS_ID_NONE);
|
||||
}
|
||||
@@ -1465,6 +1487,21 @@ void _process_EasyStatusMessage(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
EMS_Sys_Status.emsRefreshed = true; // triggers a send the values back via MQTT
|
||||
}
|
||||
|
||||
void _process_MMPLUSStatusMessage(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
uint8_t hc = (EMS_RxTelegram->type - EMS_TYPE_MMPLUSStatusMessage_HC1); // 0 to 3
|
||||
if (hc > 4) {
|
||||
return; // invalid type
|
||||
}
|
||||
EMS_Mixing.hc[hc].active = true;
|
||||
|
||||
if (EMS_RxTelegram->data_length == 1) {
|
||||
|
||||
} else if (EMS_RxTelegram->data_length > 8) {
|
||||
uint8_t hc_temp = _toShort(3);
|
||||
EMS_Mixing.hc[hc].flowTemp = _toShort(EMS_OFFSET_MMPLUSStatusMessage_flow_temp);
|
||||
}
|
||||
}
|
||||
|
||||
/**
|
||||
* type 0x01A5 - data from the Nefit RC1010/3000 thermostat (0x18) and RC300/310s on 0x10
|
||||
* EMS+ messages may come in with different offsets so handle them here
|
||||
@@ -1885,6 +1922,10 @@ void _addDevice(uint8_t model_type, uint8_t src, uint8_t product_id, char * vers
|
||||
strlcat(device_type, "Heat Pump", sizeof(device_type));
|
||||
strlcpy(device.model_string, HeatPump_Devices[i].model_string, sizeof(device.model_string));
|
||||
break;
|
||||
case EMS_MODELTYPE_MIXING:
|
||||
strlcat(device_type, "Mixing Device", sizeof(device_type));
|
||||
strlcpy(device.model_string, Mixing_Devices[i].model_string, sizeof(device.model_string));
|
||||
break;
|
||||
case EMS_MODELTYPE_OTHER:
|
||||
strlcat(device_type, "Other", sizeof(device_type));
|
||||
strlcpy(device.model_string, Other_Devices[i].model_string, sizeof(device.model_string));
|
||||
@@ -2124,6 +2165,23 @@ void _process_Version(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
return;
|
||||
}
|
||||
|
||||
// look for mixing devices
|
||||
i = 0;
|
||||
while (i < _Mixing_Devices_max) {
|
||||
if (Mixing_Devices[i].product_id == product_id) {
|
||||
typeFound = true;
|
||||
break;
|
||||
}
|
||||
i++;
|
||||
}
|
||||
|
||||
if (typeFound) {
|
||||
_addDevice(EMS_MODELTYPE_MIXING, EMS_RxTelegram->src, product_id, version, i);
|
||||
ems_doReadCommand(EMS_TYPE_MMPLUSStatusMessage_HC1, EMS_RxTelegram->src);
|
||||
EMS_Mixing.detected = true;
|
||||
return;
|
||||
}
|
||||
|
||||
// finally look for the other EMS devices
|
||||
i = 0;
|
||||
while (i < _Other_Devices_max) {
|
||||
|
||||