From 95e81ad824c4c0e468b7bd97c92f8ca6f00fb62c Mon Sep 17 00:00:00 2001 From: proddy Date: Sat, 6 Nov 2021 13:31:32 +0100 Subject: [PATCH] auto-fetch 0x14 which is not broadcasted on all boilers - https://github.com/emsesp/EMS-ESP32/issues/160#issuecomment-962444738 --- src/devices/boiler.cpp | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/src/devices/boiler.cpp b/src/devices/boiler.cpp index f3a0a56a9..11e1b0c8d 100644 --- a/src/devices/boiler.cpp +++ b/src/devices/boiler.cpp @@ -51,7 +51,7 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const register_telegram_type(0x10, F("UBAErrorMessage1"), false, MAKE_PF_CB(process_UBAErrorMessage)); register_telegram_type(0x11, F("UBAErrorMessage2"), false, MAKE_PF_CB(process_UBAErrorMessage)); register_telegram_type(0xC2, F("UBAErrorMessage3"), false, MAKE_PF_CB(process_UBAErrorMessage2)); - register_telegram_type(0x14, F("UBATotalUptime"), false, MAKE_PF_CB(process_UBATotalUptime)); + register_telegram_type(0x14, F("UBATotalUptime"), true, MAKE_PF_CB(process_UBATotalUptime)); register_telegram_type(0x15, F("UBAMaintenanceData"), false, MAKE_PF_CB(process_UBAMaintenanceData)); register_telegram_type(0x1C, F("UBAMaintenanceStatus"), false, MAKE_PF_CB(process_UBAMaintenanceStatus)); // EMS1.0 and maybe EMS+?