mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-08 00:39:50 +03:00
cleanup other devices & SM
This commit is contained in:
@@ -121,19 +121,19 @@
|
||||
|
||||
// Known EMS types
|
||||
typedef enum {
|
||||
EMS_MODEL_NONE,
|
||||
EMS_MODEL_NONE, // unset
|
||||
EMS_MODEL_ALL, // common for all devices
|
||||
|
||||
// generic ID for the boiler
|
||||
// heatpump
|
||||
EMS_MODEL_HP,
|
||||
|
||||
// solar module
|
||||
EMS_MODEL_SM,
|
||||
|
||||
// boiler
|
||||
EMS_MODEL_UBA,
|
||||
|
||||
// generic ID for the solar module
|
||||
EMS_MODEL_SOLAR_MODULE,
|
||||
|
||||
// generic ID for all the other weird devices
|
||||
EMS_MODEL_OTHER,
|
||||
|
||||
// and finally the thermostats
|
||||
// and the thermostats
|
||||
EMS_MODEL_ES73,
|
||||
EMS_MODEL_RC10,
|
||||
EMS_MODEL_RC20,
|
||||
@@ -155,56 +155,65 @@ typedef enum {
|
||||
|
||||
// EMS types for known boilers. This list will be extended when new devices are recognized.
|
||||
// The device_id is always 0x08
|
||||
// format is MODEL_ID, PRODUCT ID, DESCRIPTION
|
||||
// format is PRODUCT ID, DESCRIPTION
|
||||
const _Boiler_Type Boiler_Types[] = {
|
||||
|
||||
{EMS_MODEL_UBA, 72, "MC10 Module"},
|
||||
{EMS_MODEL_UBA, 123, "Buderus GB172/Nefit Trendline/Junkers Cerapur"},
|
||||
{EMS_MODEL_UBA, 115, "Nefit Topline Compact/Buderus GB162"},
|
||||
{EMS_MODEL_UBA, 203, "Buderus Logamax U122/Junkers Cerapur"},
|
||||
{EMS_MODEL_UBA, 208, "Buderus Logamax plus/GB192"},
|
||||
{EMS_MODEL_UBA, 64, "Sieger BK15/Nefit Smartline/Buderus GB152"},
|
||||
{EMS_MODEL_UBA, EMS_PRODUCTID_HEATRONICS, "Bosch Condens 2500/Junkers Heatronics3"},
|
||||
{EMS_MODEL_UBA, 122, "Nefit Proline"},
|
||||
{EMS_MODEL_UBA, 172, "Nefit Enviline"}
|
||||
{72, "MC10 Module"},
|
||||
{123, "Buderus GB172/Nefit Trendline/Junkers Cerapur"},
|
||||
{115, "Nefit Topline Compact/Buderus GB162"},
|
||||
{203, "Buderus Logamax U122/Junkers Cerapur"},
|
||||
{208, "Buderus Logamax plus/GB192"},
|
||||
{64, "Sieger BK15/Nefit Smartline/Buderus GB152"},
|
||||
{EMS_PRODUCTID_HEATRONICS, "Bosch Condens 2500/Junkers Heatronics3"},
|
||||
{122, "Nefit Proline"},
|
||||
{172, "Nefit Enviline"}
|
||||
|
||||
};
|
||||
|
||||
/*
|
||||
* Known Solar Module types
|
||||
* format is PRODUCT ID, DEVICE ID, DESCRIPTION
|
||||
*/
|
||||
const _SolarModule_Type SolarModule_Types[] = {
|
||||
|
||||
{EMS_MODEL_OTHER, EMS_PRODUCTID_SM10, EMS_ID_SM, "SM10 Solar Module"},
|
||||
{EMS_MODEL_OTHER, EMS_PRODUCTID_SM100, EMS_ID_SM, "SM100 Solar Module"},
|
||||
{EMS_MODEL_OTHER, EMS_PRODUCTID_ISM1, EMS_ID_SM, "Junkers ISM1 Solar Module"}
|
||||
{EMS_PRODUCTID_SM10, EMS_ID_SM, "SM10 Solar Module"},
|
||||
{EMS_PRODUCTID_SM100, EMS_ID_SM, "SM100 Solar Module"},
|
||||
{EMS_PRODUCTID_ISM1, EMS_ID_SM, "Junkers ISM1 Solar Module"}
|
||||
|
||||
};
|
||||
|
||||
|
||||
// Other EMS devices which are not considered boilers, thermostats or solar modules
|
||||
// format is PRODUCT ID, DEVICE ID, DESCRIPTION
|
||||
const _Other_Type Other_Types[] = {
|
||||
|
||||
{EMS_MODEL_OTHER, 69, 0x21, "MM10 Mixer Module"},
|
||||
{EMS_MODEL_OTHER, 71, 0x11, "WM10 Switch Module"},
|
||||
{EMS_MODEL_OTHER, 160, 0x20, "MM100 Mixing Module"},
|
||||
{EMS_MODEL_OTHER, 160, 0x21, "MM100 Mixing Module"},
|
||||
{EMS_MODEL_OTHER, 159, 0x21, "MM50 Mixing Module"},
|
||||
{EMS_MODEL_OTHER, 68, 0x09, "BC10/RFM20 Receiver"},
|
||||
{EMS_MODEL_OTHER, 190, 0x09, "BC10 Base Controller"},
|
||||
{EMS_MODEL_OTHER, 114, 0x09, "BC10 Base Controller"},
|
||||
{EMS_MODEL_OTHER, 125, 0x09, "BC25 Base Controller"},
|
||||
{EMS_MODEL_OTHER, 152, 0x09, "Junkers Controller"},
|
||||
{EMS_MODEL_OTHER, 205, 0x02, "Nefit Moduline Easy Connect"},
|
||||
{EMS_MODEL_EASY, 206, 0x02, "Bosch Easy Connect"},
|
||||
{EMS_MODEL_OTHER, 171, 0x02, "EMS-OT OpenTherm converter"},
|
||||
{EMS_MODEL_OTHER, 252, EMS_ID_HP, "HeatPump Module"},
|
||||
{EMS_MODEL_OTHER, 189, EMS_ID_GATEWAY, "Web Gateway KM200"}
|
||||
{69, 0x21, "MM10 Mixer Module"},
|
||||
{71, 0x11, "WM10 Switch Module"},
|
||||
{160, 0x20, "MM100 Mixing Module"},
|
||||
{160, 0x21, "MM100 Mixing Module"},
|
||||
{159, 0x21, "MM50 Mixing Module"},
|
||||
{68, 0x09, "BC10/RFM20 Receiver"},
|
||||
{190, 0x09, "BC10 Base Controller"},
|
||||
{114, 0x09, "BC10 Base Controller"},
|
||||
{125, 0x09, "BC25 Base Controller"},
|
||||
{152, 0x09, "Junkers Controller"},
|
||||
{205, 0x02, "Nefit Moduline Easy Connect"},
|
||||
{206, 0x02, "Bosch Easy Connect"},
|
||||
{171, 0x02, "EMS-OT OpenTherm converter"},
|
||||
{252, EMS_ID_HP, "HeatPump Module"},
|
||||
{189, EMS_ID_GATEWAY, "Web Gateway KM200"}
|
||||
|
||||
};
|
||||
|
||||
// heatpump
|
||||
// format is PRODUCT ID, DEVICE ID, DESCRIPTION
|
||||
const _HeatPump_Type HeatPump_Types[] = {
|
||||
{252, EMS_ID_HP, "HeatPump Module"}
|
||||
};
|
||||
|
||||
/*
|
||||
* Known thermostat types and their capabilities
|
||||
* format is MODEL_ID, PRODUCT ID, DEVICE ID, DESCRIPTION
|
||||
*/
|
||||
const _Thermostat_Type Thermostat_Types[] = {
|
||||
|
||||
|
||||
Reference in New Issue