mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-07 08:19:52 +03:00
SolarLoggingOnly&Bugfix
- Added solar only logging option - Added a callback message to set the setpoint of the maximum solar boiler temperature. -fixed bug with wrong device_id for solar
This commit is contained in:
54
src/ems.cpp
54
src/ems.cpp
@@ -63,6 +63,7 @@ void _process_SM100Energy(_EMS_RxTelegram * EMS_RxTelegram);
|
||||
|
||||
// ISM1
|
||||
void _process_ISM1StatusMessage(_EMS_RxTelegram * EMS_RxTelegram);
|
||||
void _process_ISM1Set(_EMS_RxTelegram * EMS_RxTelegram);
|
||||
|
||||
// HeatPump HP
|
||||
void _process_HPMonitor1(_EMS_RxTelegram * EMS_RxTelegram);
|
||||
@@ -129,6 +130,8 @@ const _EMS_Type EMS_Types[] = {
|
||||
{EMS_MODEL_OTHER, EMS_TYPE_HPMonitor1, "HeatPumpMonitor1", _process_HPMonitor1},
|
||||
{EMS_MODEL_OTHER, EMS_TYPE_HPMonitor2, "HeatPumpMonitor2", _process_HPMonitor2},
|
||||
{EMS_MODEL_OTHER, EMS_TYPE_ISM1StatusMessage, "ISM1StatusMessage", _process_ISM1StatusMessage},
|
||||
{EMS_MODEL_OTHER, EMS_TYPE_ISM1Set, "ISM1Set", _process_ISM1Set},
|
||||
|
||||
|
||||
// RC10
|
||||
{EMS_MODEL_RC10, EMS_TYPE_RCTime, "RCTime", _process_RCTime},
|
||||
@@ -301,16 +304,17 @@ void ems_init() {
|
||||
EMS_Boiler.pump_mod_min = EMS_VALUE_INT_NOTSET; // Boiler circuit pump modulation min. power
|
||||
|
||||
// Solar Module values
|
||||
EMS_SolarModule.collectorTemp = EMS_VALUE_SHORT_NOTSET; // collector temp from SM10/SM100
|
||||
EMS_SolarModule.bottomTemp = EMS_VALUE_SHORT_NOTSET; // bottom temp from SM10/SM100
|
||||
EMS_SolarModule.pumpModulation = EMS_VALUE_INT_NOTSET; // modulation solar pump SM10/SM100
|
||||
EMS_SolarModule.pump = EMS_VALUE_INT_NOTSET; // pump active
|
||||
EMS_SolarModule.EnergyLastHour = EMS_VALUE_SHORT_NOTSET;
|
||||
EMS_SolarModule.EnergyToday = EMS_VALUE_SHORT_NOTSET;
|
||||
EMS_SolarModule.EnergyTotal = EMS_VALUE_SHORT_NOTSET;
|
||||
EMS_SolarModule.device_id = EMS_ID_NONE;
|
||||
EMS_SolarModule.model_id = EMS_MODEL_NONE;
|
||||
EMS_SolarModule.product_id = EMS_ID_NONE;
|
||||
EMS_SolarModule.collectorTemp = EMS_VALUE_SHORT_NOTSET; // collector temp from SM10/SM100
|
||||
EMS_SolarModule.bottomTemp = EMS_VALUE_SHORT_NOTSET; // bottom temp from SM10/SM100
|
||||
EMS_SolarModule.pumpModulation = EMS_VALUE_INT_NOTSET; // modulation solar pump SM10/SM100
|
||||
EMS_SolarModule.pump = EMS_VALUE_INT_NOTSET; // pump active
|
||||
EMS_SolarModule.setpoint_maxBottomTemp = EMS_VALUE_SHORT_NOTSET; //setpoint for maximum solar boiler temperature
|
||||
EMS_SolarModule.EnergyLastHour = EMS_VALUE_SHORT_NOTSET;
|
||||
EMS_SolarModule.EnergyToday = EMS_VALUE_SHORT_NOTSET;
|
||||
EMS_SolarModule.EnergyTotal = EMS_VALUE_SHORT_NOTSET;
|
||||
EMS_SolarModule.device_id = EMS_ID_NONE;
|
||||
EMS_SolarModule.model_id = EMS_MODEL_NONE;
|
||||
EMS_SolarModule.product_id = EMS_ID_NONE;
|
||||
|
||||
// Other EMS devices values
|
||||
EMS_Other.HPModulation = EMS_VALUE_INT_NOTSET;
|
||||
@@ -422,11 +426,13 @@ void ems_setLogging(_EMS_SYS_LOGGING loglevel) {
|
||||
myDebug_P(PSTR("System Logging set to Verbose"));
|
||||
} else if (loglevel == EMS_SYS_LOGGING_THERMOSTAT) {
|
||||
myDebug_P(PSTR("System Logging set to Thermostat only"));
|
||||
} else if (loglevel == EMS_SYS_LOGGING_RAW) {
|
||||
} else if (loglevel == EMS_SYS_LOGGING_SOLARMODULE) {
|
||||
myDebug_P(PSTR("System Logging set to Solar Module only"));
|
||||
}else if (loglevel == EMS_SYS_LOGGING_RAW) {
|
||||
myDebug_P(PSTR("System Logging set to Raw mode"));
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
/**
|
||||
* Calculate CRC checksum using lookup table for speed
|
||||
@@ -886,12 +892,18 @@ void _printMessage(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
if ((src == EMS_Thermostat.device_id) || (dest == EMS_Thermostat.device_id)) {
|
||||
_debugPrintTelegram(output_str, EMS_RxTelegram, color_s);
|
||||
}
|
||||
} else if (EMS_Sys_Status.emsLogging == EMS_SYS_LOGGING_SOLARMODULE) {
|
||||
// only print ones to/from thermostat if logging is set to thermostat only
|
||||
if ((src == EMS_SolarModule.device_id) || (dest == EMS_SolarModule.device_id)) {
|
||||
_debugPrintTelegram(output_str, EMS_RxTelegram, color_s);
|
||||
}
|
||||
} else {
|
||||
// always print
|
||||
_debugPrintTelegram(output_str, EMS_RxTelegram, color_s);
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
/**
|
||||
* print detailed telegram
|
||||
* and then call its callback if there is one defined
|
||||
@@ -1489,6 +1501,20 @@ void _process_ISM1StatusMessage(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
/*
|
||||
* Junkers ISM1 Solar Module - type 0x0001 EMS+ for setting values
|
||||
*/
|
||||
void _process_ISM1Set(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
|
||||
|
||||
if (EMS_RxTelegram->offset == 6) {
|
||||
// e.g. 90 30 FF 06 00 01 50 (CRC=2C)
|
||||
// to implement: change max solar boiler temperature
|
||||
EMS_SolarModule.setpoint_maxBottomTemp = _toByte(0);
|
||||
}
|
||||
}
|
||||
|
||||
/**
|
||||
* UBASetPoint 0x1A
|
||||
*/
|
||||
@@ -1685,8 +1711,8 @@ void _process_Version(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
|
||||
// EMS_Other.SM = true; // we have detected a Solar Module (SM10, SM100, ISM1 ...)
|
||||
myDebug_P(PSTR("Solar Module support enabled."));
|
||||
EMS_SolarModule.model_id = Other_Types[i].model_id;
|
||||
EMS_SolarModule.device_id = Other_Types[i].device_id;
|
||||
EMS_SolarModule.model_id = SolarModule_Types[i].model_id;
|
||||
EMS_SolarModule.device_id = SolarModule_Types[i].device_id;
|
||||
EMS_SolarModule.product_id = product_id;
|
||||
strlcpy(EMS_SolarModule.version, version, sizeof(EMS_SolarModule.version));
|
||||
|
||||
|
||||
Reference in New Issue