mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-06 15:59:52 +03:00
90
CHANGELOG.md
90
CHANGELOG.md
@@ -5,6 +5,96 @@ All notable changes to this project will be documented in this file.
|
|||||||
The format is based on [Keep a Changelog](https://keepachangelog.com/en/1.0.0/),
|
The format is based on [Keep a Changelog](https://keepachangelog.com/en/1.0.0/),
|
||||||
and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0.html).
|
and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0.html).
|
||||||
|
|
||||||
|
# [3.4.0] May 23 2022
|
||||||
|
|
||||||
|
## Added
|
||||||
|
|
||||||
|
- WebUI optimizations, updated look&feel and better performance [#124](https://github.com/emsesp/EMS-ESP32/issues/124)
|
||||||
|
- Auto refresh of WebUI after successful firmware upload [#178](https://github.com/emsesp/EMS-ESP32/issues/178)
|
||||||
|
- New Customization Service in WebUI. First feature is the ability to enable/disabled Enitites (device values) from EMS devices [#206](https://github.com/emsesp/EMS-ESP32/issues/206)
|
||||||
|
- Option to disable Telnet Console [#209](https://github.com/emsesp/EMS-ESP32/issues/209)
|
||||||
|
- Added Hide SSID, Max Clients and Preferred Channel to Access Point
|
||||||
|
- Merged in MichaelDvP's changes like Fahrenheit conversion, publish single (for IOBroker) and a few other critical optimizations
|
||||||
|
- Enabled bi-directional read/write with Home Assistant, so values can be changed automatically from the UI without scripting [#265](https://github.com/emsesp/EMS-ESP32/issues/265)
|
||||||
|
- Added GC7000F Boiler [#270](https://github.com/emsesp/EMS-ESP32/issues/270)
|
||||||
|
- Revised LED flash sequence on boot up to show system health (1 flash=no ems, 2 flashes=no wifi) [#224](https://github.com/emsesp/EMS-ESP32/issues/224)
|
||||||
|
- Analog Sensor support [#271](https://github.com/emsesp/EMS-ESP32/issues/271)
|
||||||
|
- Solar cylinder priority [#247](https://github.com/emsesp/EMS-ESP32/issues/247)
|
||||||
|
- Read only mode in Settings, where EMS Tx/Write commands are blocked [#286](https://github.com/emsesp/EMS-ESP32/issues/286)
|
||||||
|
- Added 8700i Boiler device
|
||||||
|
- Added Cascade CM10 Controller device
|
||||||
|
- Add Olimex ESP32-POE-ISO to board profiles plus settings to customize Ethernet modules [#301](https://github.com/emsesp/EMS-ESP32/issues/301)
|
||||||
|
- Help text for string commands in WebUI [#320](https://github.com/emsesp/EMS-ESP32/issues/320)
|
||||||
|
- Germany translations (at compile time)
|
||||||
|
- #entities added to system/info` endpoint [#322](https://github.com/emsesp/EMS-ESP32/issues/322)
|
||||||
|
- analog outputs digital/pwm/dac
|
||||||
|
- remove MQTT retained configs if discovery is disabled
|
||||||
|
- timeout 10 min for MQTT-QoS wait
|
||||||
|
- Moduline 300 auto-temperatures T1-T4, RC300 romminfluencefactor
|
||||||
|
- RC35 parameters [#392](https://github.com/emsesp/EMS-ESP32/issues/392), [#398](https://github.com/emsesp/EMS-ESP32/issues/398)
|
||||||
|
- sync time with thermostat [#386](https://github.com/emsesp/EMS-ESP32/issues/386), [#408](https://github.com/emsesp/EMS-ESP32/issues/408)
|
||||||
|
- set mode has immediate effect [#395](https://github.com/emsesp/EMS-ESP32/issues/395)
|
||||||
|
- min/max in web value setting
|
||||||
|
- Extend customization to select if an entity is to be shown in the WebUI or forced as read-only [#317](https://github.com/emsesp/EMS-ESP32/issues/317)
|
||||||
|
- Added Moduline 400 installation parameters [PR #449 by @kwertie01](https://github.com/emsesp/EMS-ESP32/pull/449)
|
||||||
|
- Read time from IVT-controller [#439](https://github.com/emsesp/EMS-ESP32/issues/439)
|
||||||
|
- Hybrid Heatpump product-id 168 [#459](https://github.com/emsesp/EMS-ESP32/issues/459), thermostat settings
|
||||||
|
- Junkers ISM2 and IPM in warm water mode [#437](https://github.com/emsesp/EMS-ESP32/issues/437)
|
||||||
|
- Added Shower Alert trigger time and cold shot time [#436](https://github.com/emsesp/EMS-ESP32/issues/436)
|
||||||
|
- Improved Table layout in Web UI (searching, filtering, sorting, exporting to CSV)
|
||||||
|
- API fetch individual attributes from an entity [#462](https://github.com/emsesp/EMS-ESP32/issues/462)
|
||||||
|
- Option to disable mDNS
|
||||||
|
- Option for rendering booleans on dashboard [#456](https://github.com/emsesp/EMS-ESP32/issues/456)
|
||||||
|
- Upload customization settings from a file [#256](https://github.com/emsesp/EMS-ESP32/issues/256)
|
||||||
|
|
||||||
|
## Fixed
|
||||||
|
|
||||||
|
- lastcode broke MQTT JSON structure [#228](https://github.com/emsesp/EMS-ESP32/issues/228)
|
||||||
|
- fixed issue with overlapping while reading sequence of EMS1.0 telegrams
|
||||||
|
- fixed redundant telegram readings (because of offset overflow)
|
||||||
|
- added missing RC30/Moduline 400 [#243](https://github.com/emsesp/EMS-ESP32/issues/243)
|
||||||
|
- Correct modes for RC25 [#106](https://github.com/emsesp/EMS-ESP32/issues/106)
|
||||||
|
- Clean up old HA config's in MQTT before publishing data. This will prevent HA giving the 'dict' warnings [#229](https://github.com/emsesp/EMS-ESP32/issues/229)
|
||||||
|
- RC25 temperature setting [#272](https://github.com/emsesp/EMS-ESP32/issues/272)
|
||||||
|
- Buderus RC25 - "hc1 mode type" incorrect value [#273](https://github.com/emsesp/EMS-ESP32/issues/273)
|
||||||
|
- Increased number of Mixers and Heating Circuits [#294](https://github.com/emsesp/EMS-ESP32/issues/294)
|
||||||
|
- Check receive status before removing a telegram fetch [#268](https://github.com/emsesp/EMS-ESP32/issues/268), [#282](https://github.com/emsesp/EMS-ESP32/issues/282)
|
||||||
|
- Fix uploading firmware on OSX [#345](https://github.com/emsesp/EMS-ESP32/issues/345)
|
||||||
|
- Non-nested MQTT would corrupt the json [#354](https://github.com/emsesp/EMS-ESP32/issues/354)
|
||||||
|
- Burner selected max power can have a value higher than 100% [#314](https://github.com/emsesp/EMS-ESP32/issues/314)
|
||||||
|
- some missing fahrenheit calculations
|
||||||
|
- limited number of exclusions [#339](https://github.com/emsesp/EMS-ESP32/issues/339)
|
||||||
|
- MQTT sometimes would not reconnect after a WiFi outage
|
||||||
|
|
||||||
|
## Changed
|
||||||
|
|
||||||
|
- Use flash system to show system health (1 flash=no ems, 2 flashes=no wifi) [#224](https://github.com/emsesp/EMS-ESP32/issues/224)
|
||||||
|
- Renamed Dallas Sensor to Temperature Sensor in UI
|
||||||
|
- Dallas Format removed. Use the name to give each sensor an alias
|
||||||
|
- No longer MQTT subscribes to topic `/thermostat_hc<n>` as it supports a path similar to the API endpoint construct
|
||||||
|
- Show Sensors quality in WebUI
|
||||||
|
- Controller not shown in WebUI dashboard
|
||||||
|
- renamed "Home Assistant Integration" to "MQTT Discovery" in MQTT Settings [#290](https://github.com/emsesp/EMS-ESP32/issues/290)
|
||||||
|
- Show ems tx reads and writes separately
|
||||||
|
- Show ems device handlers separated for received, fetched and pending handlers.
|
||||||
|
- Wired renamed to Ethernet
|
||||||
|
- removed system/pin command, new commands in analogsensors
|
||||||
|
- system/info device-info split to name/version/brand
|
||||||
|
- exclude list uses short-names, possible flags for web/api/mqtt excludes, readonly and favorite (selection not yet implemented)
|
||||||
|
- thermostat clock formate date-time: dd.mm.yyyy hh:mm
|
||||||
|
- RC300 summermode as other thermostats `winter/summer` instead of `off/on`
|
||||||
|
|
||||||
|
## **BREAKING CHANGES:**
|
||||||
|
|
||||||
|
- Settings:
|
||||||
|
- order of Boolean Format has changed in Application Settings - check your settings
|
||||||
|
- Dallas Format setting removed. Now customize name of each Dallas sensor via the UI
|
||||||
|
- MQTT/API
|
||||||
|
- Boiler `wwheat` renamed to `ww3wayon` [#211](https://github.com/emsesp/EMS-ESP32/issues/211)
|
||||||
|
- Boiler `ww` tag renamed to `dhw`. Any custom Home Assistant lovelace dashboards will need updating.
|
||||||
|
- Renamed description of `wwtapactivated` to "turn on/off DHW". Otherwise would have looked like "boiler_dhw_turn_on_off_dhw" in HA.
|
||||||
|
- `/api/system/info` endpoint has updated keys. Now lowercase, no underscores and not capitalized. Replace "handlers" with "handlers received", "handlers fetched" and "handlers pending".
|
||||||
|
|
||||||
# [3.3.1] January 20 2022
|
# [3.3.1] January 20 2022
|
||||||
|
|
||||||
- lastcode broke MQTT JSON structure [#228](https://github.com/emsesp/EMS-ESP32/issues/228)
|
- lastcode broke MQTT JSON structure [#228](https://github.com/emsesp/EMS-ESP32/issues/228)
|
||||||
|
|||||||
@@ -1,91 +1,16 @@
|
|||||||
# Changelog
|
# Changelog
|
||||||
|
|
||||||
## [3.4.0]
|
## [3.4.1]
|
||||||
|
|
||||||
### Added
|
### Added
|
||||||
|
|
||||||
- WebUI optimizations, updated look&feel and better performance [#124](https://github.com/emsesp/EMS-ESP32/issues/124)
|
|
||||||
- Auto refresh of WebUI after successful firmware upload [#178](https://github.com/emsesp/EMS-ESP32/issues/178)
|
|
||||||
- New Customization Service in WebUI. First feature is the ability to enable/disabled Enitites (device values) from EMS devices [#206](https://github.com/emsesp/EMS-ESP32/issues/206)
|
|
||||||
- Option to disable Telnet Console [#209](https://github.com/emsesp/EMS-ESP32/issues/209)
|
|
||||||
- Added Hide SSID, Max Clients and Preferred Channel to Access Point
|
|
||||||
- Merged in MichaelDvP's changes like Fahrenheit conversion, publish single (for IOBroker) and a few other critical optimizations
|
|
||||||
- Enabled bi-directional read/write with Home Assistant, so values can be changed automatically from the UI without scripting [#265](https://github.com/emsesp/EMS-ESP32/issues/265)
|
|
||||||
- Added GC7000F Boiler [#270](https://github.com/emsesp/EMS-ESP32/issues/270)
|
|
||||||
- Revised LED flash sequence on boot up to show system health (1 flash=no ems, 2 flashes=no wifi) [#224](https://github.com/emsesp/EMS-ESP32/issues/224)
|
|
||||||
- Analog Sensor support [#271](https://github.com/emsesp/EMS-ESP32/issues/271)
|
|
||||||
- Solar cylinder priority [#247](https://github.com/emsesp/EMS-ESP32/issues/247)
|
|
||||||
- Read only mode in Settings, where EMS Tx/Write commands are blocked [#286](https://github.com/emsesp/EMS-ESP32/issues/286)
|
|
||||||
- Added 8700i Boiler device
|
|
||||||
- Added Cascade CM10 Controller device
|
|
||||||
- Add Olimex ESP32-POE-ISO to board profiles plus settings to customize Ethernet modules [#301](https://github.com/emsesp/EMS-ESP32/issues/301)
|
|
||||||
- Help text for string commands in WebUI [#320](https://github.com/emsesp/EMS-ESP32/issues/320)
|
|
||||||
- Germany translations (at compile time)
|
|
||||||
- #entities added to system/info` endpoint [#322](https://github.com/emsesp/EMS-ESP32/issues/322)
|
|
||||||
- analog outputs digital/pwm/dac
|
|
||||||
- remove MQTT retained configs if discovery is disabled
|
|
||||||
- timeout 10 min for MQTT-QoS wait
|
|
||||||
- Moduline 300 auto-temperatures T1-T4, RC300 romminfluencefactor
|
|
||||||
- RC35 parameters [#392](https://github.com/emsesp/EMS-ESP32/issues/392), [#398](https://github.com/emsesp/EMS-ESP32/issues/398)
|
|
||||||
- sync time with thermostat [#386](https://github.com/emsesp/EMS-ESP32/issues/386), [#408](https://github.com/emsesp/EMS-ESP32/issues/408)
|
|
||||||
- set mode has immediate effect [#395](https://github.com/emsesp/EMS-ESP32/issues/395)
|
|
||||||
- min/max in web value setting
|
|
||||||
- Extend customization to select if an entity is to be shown in the WebUI or forced as read-only [#317](https://github.com/emsesp/EMS-ESP32/issues/317)
|
|
||||||
- Added Moduline 400 installation parameters [PR #449 by @kwertie01](https://github.com/emsesp/EMS-ESP32/pull/449)
|
|
||||||
- Read time from IVT-controller [#439](https://github.com/emsesp/EMS-ESP32/issues/439)
|
|
||||||
- Hybrid Heatpump product-id 168 [#459](https://github.com/emsesp/EMS-ESP32/issues/459), thermostat settings
|
|
||||||
- Junkers ISM2 and IPM in warm water mode [#437](https://github.com/emsesp/EMS-ESP32/issues/437)
|
|
||||||
- Added Shower Alert trigger time and cold shot time [#436](https://github.com/emsesp/EMS-ESP32/issues/436)
|
|
||||||
- Improved Table layout in Web UI (searching, filtering, sorting, exporting to CSV)
|
|
||||||
- API fetch individual attributes from an entity [#462](https://github.com/emsesp/EMS-ESP32/issues/462)
|
|
||||||
- Option to disable mDNS
|
|
||||||
- Option for rendering booleans on dashboard [#456](https://github.com/emsesp/EMS-ESP32/issues/456)
|
|
||||||
- Upload customization settings from a file [#256](https://github.com/emsesp/EMS-ESP32/issues/256)
|
|
||||||
|
|
||||||
### Fixed
|
### Fixed
|
||||||
|
|
||||||
- lastcode broke MQTT JSON structure [#228](https://github.com/emsesp/EMS-ESP32/issues/228)
|
- fix memory leak in api [#524](https://github.com/emsesp/EMS-ESP32/issues/524)
|
||||||
- fixed issue with overlapping while reading sequence of EMS1.0 telegrams
|
|
||||||
- fixed redundant telegram readings (because of offset overflow)
|
|
||||||
- added missing RC30/Moduline 400 [#243](https://github.com/emsesp/EMS-ESP32/issues/243)
|
|
||||||
- Correct modes for RC25 [#106](https://github.com/emsesp/EMS-ESP32/issues/106)
|
|
||||||
- Clean up old HA config's in MQTT before publishing data. This will prevent HA giving the 'dict' warnings [#229](https://github.com/emsesp/EMS-ESP32/issues/229)
|
|
||||||
- RC25 temperature setting [#272](https://github.com/emsesp/EMS-ESP32/issues/272)
|
|
||||||
- Buderus RC25 - "hc1 mode type" incorrect value [#273](https://github.com/emsesp/EMS-ESP32/issues/273)
|
|
||||||
- Increased number of Mixers and Heating Circuits [#294](https://github.com/emsesp/EMS-ESP32/issues/294)
|
|
||||||
- Check receive status before removing a telegram fetch [#268](https://github.com/emsesp/EMS-ESP32/issues/268), [#282](https://github.com/emsesp/EMS-ESP32/issues/282)
|
|
||||||
- Fix uploading firmware on OSX [#345](https://github.com/emsesp/EMS-ESP32/issues/345)
|
|
||||||
- Non-nested MQTT would corrupt the json [#354](https://github.com/emsesp/EMS-ESP32/issues/354)
|
|
||||||
- Burner selected max power can have a value higher than 100% [#314](https://github.com/emsesp/EMS-ESP32/issues/314)
|
|
||||||
- some missing fahrenheit calculations
|
|
||||||
- limited number of exclusions [#339](https://github.com/emsesp/EMS-ESP32/issues/339)
|
|
||||||
- MQTT sometimes would not reconnect after a WiFi outage
|
|
||||||
|
|
||||||
### Changed
|
### Changed
|
||||||
|
|
||||||
- Use flash system to show system health (1 flash=no ems, 2 flashes=no wifi) [#224](https://github.com/emsesp/EMS-ESP32/issues/224)
|
- controller data in web-ui only for IVT [#522](https://github.com/emsesp/EMS-ESP32/issues/522)
|
||||||
- Renamed Dallas Sensor to Temperature Sensor in UI
|
- rename hidden `climate` to a more explaining name [#523](https://github.com/emsesp/EMS-ESP32/issues/523)
|
||||||
- Dallas Format removed. Use the name to give each sensor an alias
|
|
||||||
- No longer MQTT subscribes to topic `/thermostat_hc<n>` as it supports a path similar to the API endpoint construct
|
|
||||||
- Show Sensors quality in WebUI
|
|
||||||
- Controller not shown in WebUI dashboard
|
|
||||||
- renamed "Home Assistant Integration" to "MQTT Discovery" in MQTT Settings [#290](https://github.com/emsesp/EMS-ESP32/issues/290)
|
|
||||||
- Show ems tx reads and writes separately
|
|
||||||
- Show ems device handlers separated for received, fetched and pending handlers.
|
|
||||||
- Wired renamed to Ethernet
|
|
||||||
- removed system/pin command, new commands in analogsensors
|
|
||||||
- system/info device-info split to name/version/brand
|
|
||||||
- exclude list uses short-names, possible flags for web/api/mqtt excludes, readonly and favorite (selection not yet implemented)
|
|
||||||
- thermostat clock formate date-time: dd.mm.yyyy hh:mm
|
|
||||||
- RC300 summermode as other thermostats `winter/summer` instead of `off/on`
|
|
||||||
|
|
||||||
## **BREAKING CHANGES:**
|
## **BREAKING CHANGES:**
|
||||||
|
|
||||||
- Settings:
|
|
||||||
- order of Boolean Format has changed in Application Settings - check your settings
|
|
||||||
- Dallas Format setting removed. Now customize name of each Dallas sensor via the UI
|
|
||||||
- MQTT/API
|
|
||||||
- Boiler `wwheat` renamed to `ww3wayon` [#211](https://github.com/emsesp/EMS-ESP32/issues/211)
|
|
||||||
- Boiler `ww` tag renamed to `dhw`. Any custom Home Assistant lovelace dashboards will need updating.
|
|
||||||
- Renamed description of `wwtapactivated` to "turn on/off DHW". Otherwise would have looked like "boiler_dhw_turn_on_off_dhw" in HA.
|
|
||||||
- `/api/system/info` endpoint has updated keys. Now lowercase, no underscores and not capitalized. Replace "handlers" with "handlers received", "handlers fetched" and "handlers pending".
|
|
||||||
|
|||||||
@@ -68,7 +68,7 @@
|
|||||||
{224, DeviceType::CONTROLLER, F("9000i"), DeviceFlags::EMS_DEVICE_FLAG_NONE}, // 0x09
|
{224, DeviceType::CONTROLLER, F("9000i"), DeviceFlags::EMS_DEVICE_FLAG_NONE}, // 0x09
|
||||||
{229, DeviceType::CONTROLLER, F("8700i"), DeviceFlags::EMS_DEVICE_FLAG_NONE}, // 0x09
|
{229, DeviceType::CONTROLLER, F("8700i"), DeviceFlags::EMS_DEVICE_FLAG_NONE}, // 0x09
|
||||||
{230, DeviceType::CONTROLLER, F("BC Base"), DeviceFlags::EMS_DEVICE_FLAG_NONE}, // 0x09
|
{230, DeviceType::CONTROLLER, F("BC Base"), DeviceFlags::EMS_DEVICE_FLAG_NONE}, // 0x09
|
||||||
{240, DeviceType::CONTROLLER, F("Rego 3000"), DeviceFlags::EMS_DEVICE_FLAG_NONE}, // 0x09
|
{240, DeviceType::CONTROLLER, F("Rego 3000"), DeviceFlags::EMS_DEVICE_FLAG_IVT}, // 0x09
|
||||||
{241, DeviceType::CONTROLLER, F("Condens 5000i"), DeviceFlags::EMS_DEVICE_FLAG_NONE}, // 0x09
|
{241, DeviceType::CONTROLLER, F("Condens 5000i"), DeviceFlags::EMS_DEVICE_FLAG_NONE}, // 0x09
|
||||||
|
|
||||||
// Thermostat - not currently supporting write operations, like the Easy/100 types - 0x18
|
// Thermostat - not currently supporting write operations, like the Easy/100 types - 0x18
|
||||||
|
|||||||
@@ -25,8 +25,10 @@ REGISTER_FACTORY(Controller, EMSdevice::DeviceType::CONTROLLER);
|
|||||||
Controller::Controller(uint8_t device_type, uint8_t device_id, uint8_t product_id, const char * version, const std::string & name, uint8_t flags, uint8_t brand)
|
Controller::Controller(uint8_t device_type, uint8_t device_id, uint8_t product_id, const char * version, const std::string & name, uint8_t flags, uint8_t brand)
|
||||||
: EMSdevice(device_type, device_id, product_id, version, name, flags, brand) {
|
: EMSdevice(device_type, device_id, product_id, version, name, flags, brand) {
|
||||||
// IVT broadcasts Thermostat time from controller (0x09) if display is off.
|
// IVT broadcasts Thermostat time from controller (0x09) if display is off.
|
||||||
register_telegram_type(0x06, F("RCTime"), false, MAKE_PF_CB(process_dateTime));
|
if ((flags & 0x0F) == EMS_DEVICE_FLAG_IVT) {
|
||||||
register_device_value(DeviceValueTAG::TAG_NONE, &dateTime_, DeviceValueType::STRING, nullptr, FL_(dateTime), DeviceValueUOM::NONE);
|
register_telegram_type(0x06, F("RCTime"), false, MAKE_PF_CB(process_dateTime));
|
||||||
|
register_device_value(DeviceValueTAG::TAG_NONE, &dateTime_, DeviceValueType::STRING, nullptr, FL_(dateTime), DeviceValueUOM::NONE);
|
||||||
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
// process_dateTime - type 0x06 - date and time from a thermostat - 14 bytes long, IVT only
|
// process_dateTime - type 0x06 - date and time from a thermostat - 14 bytes long, IVT only
|
||||||
|
|||||||
@@ -315,6 +315,9 @@ class EMSdevice {
|
|||||||
// device flags: The lower 4 bits hold the unique identifier, the upper 4 bits are used for specific flags
|
// device flags: The lower 4 bits hold the unique identifier, the upper 4 bits are used for specific flags
|
||||||
static constexpr uint8_t EMS_DEVICE_FLAG_NONE = 0;
|
static constexpr uint8_t EMS_DEVICE_FLAG_NONE = 0;
|
||||||
|
|
||||||
|
// Controller
|
||||||
|
static constexpr uint8_t EMS_DEVICE_FLAG_IVT = 1;
|
||||||
|
|
||||||
// Boiler
|
// Boiler
|
||||||
static constexpr uint8_t EMS_DEVICE_FLAG_EMS = 1;
|
static constexpr uint8_t EMS_DEVICE_FLAG_EMS = 1;
|
||||||
static constexpr uint8_t EMS_DEVICE_FLAG_EMSPLUS = 2;
|
static constexpr uint8_t EMS_DEVICE_FLAG_EMSPLUS = 2;
|
||||||
|
|||||||
@@ -616,7 +616,7 @@ MAKE_PSTR_LIST(wwDailyHeating, F("wwdailyheating"), F("daily heating"))
|
|||||||
MAKE_PSTR_LIST(wwDailyHeatTime, F("wwdailyheattime"), F("daily heating time"))
|
MAKE_PSTR_LIST(wwDailyHeatTime, F("wwdailyheattime"), F("daily heating time"))
|
||||||
MAKE_PSTR_LIST(wwWhenModeOff, F("wwwhenmodeoff"), F("when thermostat mode off"))
|
MAKE_PSTR_LIST(wwWhenModeOff, F("wwwhenmodeoff"), F("when thermostat mode off"))
|
||||||
// thermostat hc
|
// thermostat hc
|
||||||
MAKE_PSTR_LIST(climate, F("climate"))
|
MAKE_PSTR_LIST(climate, F("ha_climate_config_creation")) // no full-name, hidden, only for creation
|
||||||
MAKE_PSTR_LIST(selRoomTemp, F("seltemp"), F("selected room temperature"))
|
MAKE_PSTR_LIST(selRoomTemp, F("seltemp"), F("selected room temperature"))
|
||||||
MAKE_PSTR_LIST(roomTemp, F("currtemp"), F("current room temperature"))
|
MAKE_PSTR_LIST(roomTemp, F("currtemp"), F("current room temperature"))
|
||||||
MAKE_PSTR_LIST(mode, F("mode"), F("mode"))
|
MAKE_PSTR_LIST(mode, F("mode"), F("mode"))
|
||||||
|
|||||||
@@ -132,6 +132,7 @@ void WebAPIService::parse(AsyncWebServerRequest * request, JsonObject & input) {
|
|||||||
JsonVariant data = output["api_data"];
|
JsonVariant data = output["api_data"];
|
||||||
request->send(200, "text/plain; charset=utf-8", data.as<String>());
|
request->send(200, "text/plain; charset=utf-8", data.as<String>());
|
||||||
api_count_++;
|
api_count_++;
|
||||||
|
delete response;
|
||||||
return;
|
return;
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|||||||
Reference in New Issue
Block a user