diff --git a/src/devices/boiler.cpp b/src/devices/boiler.cpp index 1a776e121..6ee569cef 100644 --- a/src/devices/boiler.cpp +++ b/src/devices/boiler.cpp @@ -594,8 +594,8 @@ void Boiler::process_UBAParameterWWPlus(std::shared_ptr telegram has_update(telegram->read_value(wwActivated_, 5)); // 0x01 means on has_update(telegram->read_value(wwCircPump_, 10)); // 0x01 means yes has_update(telegram->read_value(wwCircMode_, 11)); // 1=1x3min... 6=6x3min, 7=continuous - // has_update(telegram->read_value(wWDisinfectTemp_, 12)); // settings, status in E9 - // has_update(telegram->read_value(wWSelTemp_, 6)); // settings, status in E9 + has_update(telegram->read_value(wWDisinfectTemp_, 12)); + has_update(telegram->read_value(wWSelTemp_, 6)); has_update(telegram->read_value(wwHystOn_, 7)); has_update(telegram->read_value(wwHystOff_, 8)); has_update(telegram->read_value(wwSelTempOff_, 0)); // confusing description in #96, hopefully this is right @@ -621,8 +621,8 @@ void Boiler::process_UBAMonitorWWPlus(std::shared_ptr telegram) has_update(telegram->read_bitvalue(wwCirc_, 13, 2)); // has_update(telegram->read_value(wWActivated_, 20)); // Activated is in 0xEA, this is something other 0/100% - has_update(telegram->read_value(wwSelTemp_, 10)); - has_update(telegram->read_value(wwDisinfectionTemp_, 9)); + // has_update(telegram->read_value(wwSelTemp_, 10)); // see #96, this is not wwSelTemp (set in EA) + // has_update(telegram->read_value(wwDisinfectionTemp_, 9)); } /*