From 5f0d49e13b05cdc3b003853f4a4859c547cf5f72 Mon Sep 17 00:00:00 2001 From: proddy Date: Sat, 19 Oct 2024 12:14:53 +0200 Subject: [PATCH 1/2] package update --- interface/package.json | 10 +-- interface/yarn.lock | 178 ++++++++++++++++++++--------------------- mock-api/package.json | 2 +- mock-api/yarn.lock | 20 ++--- 4 files changed, 105 insertions(+), 105 deletions(-) diff --git a/interface/package.json b/interface/package.json index 45af3a462..8fb2e1a10 100644 --- a/interface/package.json +++ b/interface/package.json @@ -42,23 +42,23 @@ }, "devDependencies": { "@babel/core": "^7.25.8", - "@eslint/js": "^9.12.0", + "@eslint/js": "^9.13.0", "@preact/compat": "^18.3.1", "@preact/preset-vite": "^2.9.1", "@trivago/prettier-plugin-sort-imports": "^4.3.0", "@types/formidable": "^3", - "@types/node": "^22.7.6", + "@types/node": "^22.7.7", "@types/react": "^18.3.11", "@types/react-dom": "^18.3.1", "@types/react-router-dom": "^5.3.3", "concurrently": "^9.0.1", - "eslint": "^9.12.0", + "eslint": "^9.13.0", "eslint-config-prettier": "^9.1.0", - "formidable": "^3.5.1", + "formidable": "^3.5.2", "prettier": "^3.3.3", "rollup-plugin-visualizer": "^5.12.0", "terser": "^5.36.0", - "typescript-eslint": "8.9.0", + "typescript-eslint": "8.10.0", "vite": "^5.4.9", "vite-plugin-imagemin": "^0.6.1", "vite-tsconfig-paths": "^5.0.1" diff --git a/interface/yarn.lock b/interface/yarn.lock index 81da6fb3a..d93dc53e0 100644 --- a/interface/yarn.lock +++ b/interface/yarn.lock @@ -925,10 +925,10 @@ __metadata: languageName: node linkType: hard -"@eslint/core@npm:^0.6.0": - version: 0.6.0 - resolution: "@eslint/core@npm:0.6.0" - checksum: 10c0/fffdb3046ad6420f8cb9204b6466fdd8632a9baeebdaf2a97d458a4eac0e16653ba50d82d61835d7d771f6ced0ec942ec482b2fbccc300e45f2cbf784537f240 +"@eslint/core@npm:^0.7.0": + version: 0.7.0 + resolution: "@eslint/core@npm:0.7.0" + checksum: 10c0/3cdee8bc6cbb96ac6103d3ead42e59830019435839583c9eb352b94ed558bd78e7ffad5286dc710df21ec1e7bd8f52aa6574c62457a4dd0f01f3736fa4a7d87a languageName: node linkType: hard @@ -949,10 +949,10 @@ __metadata: languageName: node linkType: hard -"@eslint/js@npm:9.12.0, @eslint/js@npm:^9.12.0": - version: 9.12.0 - resolution: "@eslint/js@npm:9.12.0" - checksum: 10c0/325650a59a1ce3d97c69441501ebaf415607248bacbe8c8ca35adc7cb73b524f592f266a75772f496b06f3239e3ee1996722a242148085f0ee5fb3dd7065897c +"@eslint/js@npm:9.13.0, @eslint/js@npm:^9.13.0": + version: 9.13.0 + resolution: "@eslint/js@npm:9.13.0" + checksum: 10c0/672257bffe17777b8a98bd80438702904cc7a0b98b9c2e426a8a10929198b3553edf8a3fc20feed4133c02e7c8f7331a0ef1b23e5dab8e4469f7f1791beff1e0 languageName: node linkType: hard @@ -1685,12 +1685,12 @@ __metadata: languageName: node linkType: hard -"@types/node@npm:^22.7.6": - version: 22.7.6 - resolution: "@types/node@npm:22.7.6" +"@types/node@npm:^22.7.7": + version: 22.7.7 + resolution: "@types/node@npm:22.7.7" dependencies: undici-types: "npm:~6.19.2" - checksum: 10c0/d4406a63afce981c363fb1d1954aaf1759ad2d487c0833ebf667565ea4e45ff217d6fab4b5343badbdeccdf9d2e4a0841d633e0c929ceabcb33c288663dd0c73 + checksum: 10c0/07268a1e990ad9d9b1865092881317ea679a46eb6706d83a8874eec75fdddae6cfd6452e4e68b651561183e2a8f8548276f3155744bc402c2545978c19b70d65 languageName: node linkType: hard @@ -1785,15 +1785,15 @@ __metadata: languageName: node linkType: hard -"@typescript-eslint/eslint-plugin@npm:8.9.0": - version: 8.9.0 - resolution: "@typescript-eslint/eslint-plugin@npm:8.9.0" +"@typescript-eslint/eslint-plugin@npm:8.10.0": + version: 8.10.0 + resolution: "@typescript-eslint/eslint-plugin@npm:8.10.0" dependencies: "@eslint-community/regexpp": "npm:^4.10.0" - "@typescript-eslint/scope-manager": "npm:8.9.0" - "@typescript-eslint/type-utils": "npm:8.9.0" - "@typescript-eslint/utils": "npm:8.9.0" - "@typescript-eslint/visitor-keys": "npm:8.9.0" + "@typescript-eslint/scope-manager": "npm:8.10.0" + "@typescript-eslint/type-utils": "npm:8.10.0" + "@typescript-eslint/utils": "npm:8.10.0" + "@typescript-eslint/visitor-keys": "npm:8.10.0" graphemer: "npm:^1.4.0" ignore: "npm:^5.3.1" natural-compare: "npm:^1.4.0" @@ -1804,66 +1804,66 @@ __metadata: peerDependenciesMeta: typescript: optional: true - checksum: 10c0/07f273dc270268980bbf65ea5e0c69d05377e42dbdb2dd3f4a1293a3536c049ddfb548eb9ec6e60394c2361c4a15b62b8246951f83e16a9d16799578a74dc691 + checksum: 10c0/4b77ba9c865a2a14e238cd330b5901f0274b8ce1c13324fccd0339b8eea82a50a4709394c903fd8cd5bd0d3aebace0761ff9a4a19fa20b00bb61349b7671c035 languageName: node linkType: hard -"@typescript-eslint/parser@npm:8.9.0": - version: 8.9.0 - resolution: "@typescript-eslint/parser@npm:8.9.0" +"@typescript-eslint/parser@npm:8.10.0": + version: 8.10.0 + resolution: "@typescript-eslint/parser@npm:8.10.0" dependencies: - "@typescript-eslint/scope-manager": "npm:8.9.0" - "@typescript-eslint/types": "npm:8.9.0" - "@typescript-eslint/typescript-estree": "npm:8.9.0" - "@typescript-eslint/visitor-keys": "npm:8.9.0" + "@typescript-eslint/scope-manager": "npm:8.10.0" + "@typescript-eslint/types": "npm:8.10.0" + "@typescript-eslint/typescript-estree": "npm:8.10.0" + "@typescript-eslint/visitor-keys": "npm:8.10.0" debug: "npm:^4.3.4" peerDependencies: eslint: ^8.57.0 || ^9.0.0 peerDependenciesMeta: typescript: optional: true - checksum: 10c0/aca7c838de85fb700ecf5682dc6f8f90a0fbfe09a3044a176c0dc3ffd9c5e7105beb0919a30824f46b02223a74119b4f5a9834a0663328987f066cb359b5dbed + checksum: 10c0/7becb2457c085c239838d301796074b790f46dd38c9fbc14ec1dec8e993c7115cd8a66cdc07983c3a68a2dd92e24e8acc49d69a4ebcc29e9869957eb52d1cb74 languageName: node linkType: hard -"@typescript-eslint/scope-manager@npm:8.9.0": - version: 8.9.0 - resolution: "@typescript-eslint/scope-manager@npm:8.9.0" +"@typescript-eslint/scope-manager@npm:8.10.0": + version: 8.10.0 + resolution: "@typescript-eslint/scope-manager@npm:8.10.0" dependencies: - "@typescript-eslint/types": "npm:8.9.0" - "@typescript-eslint/visitor-keys": "npm:8.9.0" - checksum: 10c0/1fb77a982e3384d8cabd64678ea8f9de328708080ff9324bf24a44da4e8d7b7692ae4820efc3ef36027bf0fd6a061680d3c30ce63d661fb31e18970fca5e86c5 + "@typescript-eslint/types": "npm:8.10.0" + "@typescript-eslint/visitor-keys": "npm:8.10.0" + checksum: 10c0/b8bb8635c4d6c00a3578d6265e3ee0f5d96d0c9dee534ed588aa411c3f4497fd71cce730c3ae7571e52453d955b191bc9edcc47c9af21a20c90e9a20f2371108 languageName: node linkType: hard -"@typescript-eslint/type-utils@npm:8.9.0": - version: 8.9.0 - resolution: "@typescript-eslint/type-utils@npm:8.9.0" +"@typescript-eslint/type-utils@npm:8.10.0": + version: 8.10.0 + resolution: "@typescript-eslint/type-utils@npm:8.10.0" dependencies: - "@typescript-eslint/typescript-estree": "npm:8.9.0" - "@typescript-eslint/utils": "npm:8.9.0" + "@typescript-eslint/typescript-estree": "npm:8.10.0" + "@typescript-eslint/utils": "npm:8.10.0" debug: "npm:^4.3.4" ts-api-utils: "npm:^1.3.0" peerDependenciesMeta: typescript: optional: true - checksum: 10c0/aff06afda9ac7d12f750e76c8f91ed8b56eefd3f3f4fbaa93a64411ec9e0bd2c2972f3407e439320d98062b16f508dce7604b8bb2b803fded9d3148e5ee721b1 + checksum: 10c0/1af8fce8394279e6ac7bcef449a132072ee36e374c8d557564246ffe7150230844901ca0305e29525bf37c87010e03bf8bedec76fccbfe1e41931cb4f274e208 languageName: node linkType: hard -"@typescript-eslint/types@npm:8.9.0": - version: 8.9.0 - resolution: "@typescript-eslint/types@npm:8.9.0" - checksum: 10c0/8d901b7ed2f943624c24f7fa67f7be9d49a92554d54c4f27397c05b329ceff59a9ea246810b53ff36fca08760c14305dd4ce78fbac7ca0474311b0575bf49010 +"@typescript-eslint/types@npm:8.10.0": + version: 8.10.0 + resolution: "@typescript-eslint/types@npm:8.10.0" + checksum: 10c0/f27dd43c8383e02e914a254257627e393dfc0f08b0f74a253c106813ae361f090271b2f3f2ef588fa3ca1329897d873da595bb5641fe8e3091b25eddca24b5d2 languageName: node linkType: hard -"@typescript-eslint/typescript-estree@npm:8.9.0": - version: 8.9.0 - resolution: "@typescript-eslint/typescript-estree@npm:8.9.0" +"@typescript-eslint/typescript-estree@npm:8.10.0": + version: 8.10.0 + resolution: "@typescript-eslint/typescript-estree@npm:8.10.0" dependencies: - "@typescript-eslint/types": "npm:8.9.0" - "@typescript-eslint/visitor-keys": "npm:8.9.0" + "@typescript-eslint/types": "npm:8.10.0" + "@typescript-eslint/visitor-keys": "npm:8.10.0" debug: "npm:^4.3.4" fast-glob: "npm:^3.3.2" is-glob: "npm:^4.0.3" @@ -1873,31 +1873,31 @@ __metadata: peerDependenciesMeta: typescript: optional: true - checksum: 10c0/bb5ec70727f07d1575e95f9d117762636209e1ab073a26c4e873e1e5b4617b000d300a23d294ad81693f7e99abe3e519725452c30b235a253edcd85b6ae052b0 + checksum: 10c0/535a740fe25be0e28fe68c41e3264273d1e5169c9f938e08cc0e3415c357726f43efa44621960108c318fc3305c425d29f3223b6e731d44d67f84058a8947304 languageName: node linkType: hard -"@typescript-eslint/utils@npm:8.9.0": - version: 8.9.0 - resolution: "@typescript-eslint/utils@npm:8.9.0" +"@typescript-eslint/utils@npm:8.10.0": + version: 8.10.0 + resolution: "@typescript-eslint/utils@npm:8.10.0" dependencies: "@eslint-community/eslint-utils": "npm:^4.4.0" - "@typescript-eslint/scope-manager": "npm:8.9.0" - "@typescript-eslint/types": "npm:8.9.0" - "@typescript-eslint/typescript-estree": "npm:8.9.0" + "@typescript-eslint/scope-manager": "npm:8.10.0" + "@typescript-eslint/types": "npm:8.10.0" + "@typescript-eslint/typescript-estree": "npm:8.10.0" peerDependencies: eslint: ^8.57.0 || ^9.0.0 - checksum: 10c0/af13e3d501060bdc5fa04b131b3f9a90604e5c1d4845d1f8bd94b703a3c146a76debfc21fe65a7f3a0459ed6c57cf2aa3f0a052469bb23b6f35ff853fe9495b1 + checksum: 10c0/a21a2933517176abd00fcd5d8d80023e35dc3d89d5746bbac43790b4e984ab1f371117db08048bce7f42d54c64f4e0e35161149f8f34fd25a27bff9d1110fd16 languageName: node linkType: hard -"@typescript-eslint/visitor-keys@npm:8.9.0": - version: 8.9.0 - resolution: "@typescript-eslint/visitor-keys@npm:8.9.0" +"@typescript-eslint/visitor-keys@npm:8.10.0": + version: 8.10.0 + resolution: "@typescript-eslint/visitor-keys@npm:8.10.0" dependencies: - "@typescript-eslint/types": "npm:8.9.0" + "@typescript-eslint/types": "npm:8.10.0" eslint-visitor-keys: "npm:^3.4.3" - checksum: 10c0/e33208b946841f1838d87d64f4ee230f798e68bdce8c181d3ac0abb567f758cb9c4bdccc919d493167869f413ca4c400e7db0f7dd7e8fc84ab6a8344076a7458 + checksum: 10c0/14721c4ac939640d5fd1ee1b6eeb07604b11a6017e319e21dcc71e7aac2992341fc7ae1992d977bad4433b6a1d0d1c0c279e6927316b26245f6e333f922fa458 languageName: node linkType: hard @@ -1909,7 +1909,7 @@ __metadata: "@babel/core": "npm:^7.25.8" "@emotion/react": "npm:^11.13.3" "@emotion/styled": "npm:^11.13.0" - "@eslint/js": "npm:^9.12.0" + "@eslint/js": "npm:^9.13.0" "@mui/icons-material": "npm:^6.1.4" "@mui/material": "npm:^6.1.4" "@preact/compat": "npm:^18.3.1" @@ -1917,16 +1917,16 @@ __metadata: "@table-library/react-table-library": "npm:4.1.7" "@trivago/prettier-plugin-sort-imports": "npm:^4.3.0" "@types/formidable": "npm:^3" - "@types/node": "npm:^22.7.6" + "@types/node": "npm:^22.7.7" "@types/react": "npm:^18.3.11" "@types/react-dom": "npm:^18.3.1" "@types/react-router-dom": "npm:^5.3.3" alova: "npm:3.1.0" async-validator: "npm:^4.2.5" concurrently: "npm:^9.0.1" - eslint: "npm:^9.12.0" + eslint: "npm:^9.13.0" eslint-config-prettier: "npm:^9.1.0" - formidable: "npm:^3.5.1" + formidable: "npm:^3.5.2" jwt-decode: "npm:^4.0.0" mime-types: "npm:^2.1.35" preact: "npm:^10.24.3" @@ -1940,7 +1940,7 @@ __metadata: terser: "npm:^5.36.0" typesafe-i18n: "npm:^5.26.2" typescript: "npm:^5.6.3" - typescript-eslint: "npm:8.9.0" + typescript-eslint: "npm:8.10.0" vite: "npm:^5.4.9" vite-plugin-imagemin: "npm:^0.6.1" vite-tsconfig-paths: "npm:^5.0.1" @@ -3411,16 +3411,16 @@ __metadata: languageName: node linkType: hard -"eslint@npm:^9.12.0": - version: 9.12.0 - resolution: "eslint@npm:9.12.0" +"eslint@npm:^9.13.0": + version: 9.13.0 + resolution: "eslint@npm:9.13.0" dependencies: "@eslint-community/eslint-utils": "npm:^4.2.0" "@eslint-community/regexpp": "npm:^4.11.0" "@eslint/config-array": "npm:^0.18.0" - "@eslint/core": "npm:^0.6.0" + "@eslint/core": "npm:^0.7.0" "@eslint/eslintrc": "npm:^3.1.0" - "@eslint/js": "npm:9.12.0" + "@eslint/js": "npm:9.13.0" "@eslint/plugin-kit": "npm:^0.2.0" "@humanfs/node": "npm:^0.16.5" "@humanwhocodes/module-importer": "npm:^1.0.1" @@ -3457,7 +3457,7 @@ __metadata: optional: true bin: eslint: bin/eslint.js - checksum: 10c0/67cf6ea3ea28dcda7dd54aac33e2d4028eb36991d13defb0d2339c3eaa877d5dddd12cd4416ddc701a68bcde9e0bb9e65524c2e4e9914992c724f5b51e949dda + checksum: 10c0/d3577444152182a9d8ea8c6a6acb073d3a2773ad73a6b646f432746583ec4bfcd6a44fcc2e37d05d276984e583c46c2d289b3b981ca8f8b4052756a152341d19 languageName: node linkType: hard @@ -3844,14 +3844,14 @@ __metadata: languageName: node linkType: hard -"formidable@npm:^3.5.1": - version: 3.5.1 - resolution: "formidable@npm:3.5.1" +"formidable@npm:^3.5.2": + version: 3.5.2 + resolution: "formidable@npm:3.5.2" dependencies: dezalgo: "npm:^1.0.4" - hexoid: "npm:^1.0.0" + hexoid: "npm:^2.0.0" once: "npm:^1.4.0" - checksum: 10c0/c02fa1a027876dd9fc5abde16e9c537bec41bc652b362d0b3fd26daaae0615b9a472129c29b328a130d11f543f676acd1b13e6f28f3adc1b088cdaea9fb9e054 + checksum: 10c0/c26d89ba84d392f0e68ba1aca9f779e0f2e94db053d95df562c730782956f302e3f069c07ab96f991415af915ac7b8771f4c813d298df43577fdf439e1e8741e languageName: node linkType: hard @@ -4236,10 +4236,10 @@ __metadata: languageName: node linkType: hard -"hexoid@npm:^1.0.0": - version: 1.0.0 - resolution: "hexoid@npm:1.0.0" - checksum: 10c0/9c45e8ba676b9eb88455631ebceec4c829a8374a583410dc735472ab9808bf11339fcd074633c3fa30e420901b894d8a92ffd5e2e21eddd41149546e05a91f69 +"hexoid@npm:^2.0.0": + version: 2.0.0 + resolution: "hexoid@npm:2.0.0" + checksum: 10c0/a9d5e6f4adeaefcb4a53803dd48bf0a242d92e8ec699555aea616c4bf8f91788f03093595085976f63d6830815dd080c063503540fabc7e854ebfb11161687c6 languageName: node linkType: hard @@ -7042,17 +7042,17 @@ __metadata: languageName: node linkType: hard -"typescript-eslint@npm:8.9.0": - version: 8.9.0 - resolution: "typescript-eslint@npm:8.9.0" +"typescript-eslint@npm:8.10.0": + version: 8.10.0 + resolution: "typescript-eslint@npm:8.10.0" dependencies: - "@typescript-eslint/eslint-plugin": "npm:8.9.0" - "@typescript-eslint/parser": "npm:8.9.0" - "@typescript-eslint/utils": "npm:8.9.0" + "@typescript-eslint/eslint-plugin": "npm:8.10.0" + "@typescript-eslint/parser": "npm:8.10.0" + "@typescript-eslint/utils": "npm:8.10.0" peerDependenciesMeta: typescript: optional: true - checksum: 10c0/96bef4f5d1da9561078fa234642cfa2d024979917b8282b82f63956789bc566bdd5806ff2b414697f3dfdee314e9c9fec05911a7502550d763a496e2ef3af2fd + checksum: 10c0/9eca1bfdea4e108bea06f0053b57f8a9eaeb43bf3316a39c6d29631bd3217ec67611e46d361417c48a5f6eeb99c4a7fc81c020734b1b47d7b8e42fa67d74ea0f languageName: node linkType: hard diff --git a/mock-api/package.json b/mock-api/package.json index 4fa0d5135..d8286d704 100644 --- a/mock-api/package.json +++ b/mock-api/package.json @@ -11,7 +11,7 @@ "dependencies": { "@msgpack/msgpack": "^2.8.0", "@trivago/prettier-plugin-sort-imports": "^4.3.0", - "formidable": "^3.5.1", + "formidable": "^3.5.2", "itty-router": "^5.0.18", "prettier": "^3.3.3" }, diff --git a/mock-api/yarn.lock b/mock-api/yarn.lock index 96d6d33d6..10d6ae783 100644 --- a/mock-api/yarn.lock +++ b/mock-api/yarn.lock @@ -303,14 +303,14 @@ __metadata: languageName: node linkType: hard -"formidable@npm:^3.5.1": - version: 3.5.1 - resolution: "formidable@npm:3.5.1" +"formidable@npm:^3.5.2": + version: 3.5.2 + resolution: "formidable@npm:3.5.2" dependencies: dezalgo: "npm:^1.0.4" - hexoid: "npm:^1.0.0" + hexoid: "npm:^2.0.0" once: "npm:^1.4.0" - checksum: 10c0/c02fa1a027876dd9fc5abde16e9c537bec41bc652b362d0b3fd26daaae0615b9a472129c29b328a130d11f543f676acd1b13e6f28f3adc1b088cdaea9fb9e054 + checksum: 10c0/c26d89ba84d392f0e68ba1aca9f779e0f2e94db053d95df562c730782956f302e3f069c07ab96f991415af915ac7b8771f4c813d298df43577fdf439e1e8741e languageName: node linkType: hard @@ -328,10 +328,10 @@ __metadata: languageName: node linkType: hard -"hexoid@npm:^1.0.0": - version: 1.0.0 - resolution: "hexoid@npm:1.0.0" - checksum: 10c0/9c45e8ba676b9eb88455631ebceec4c829a8374a583410dc735472ab9808bf11339fcd074633c3fa30e420901b894d8a92ffd5e2e21eddd41149546e05a91f69 +"hexoid@npm:^2.0.0": + version: 2.0.0 + resolution: "hexoid@npm:2.0.0" + checksum: 10c0/a9d5e6f4adeaefcb4a53803dd48bf0a242d92e8ec699555aea616c4bf8f91788f03093595085976f63d6830815dd080c063503540fabc7e854ebfb11161687c6 languageName: node linkType: hard @@ -378,7 +378,7 @@ __metadata: dependencies: "@msgpack/msgpack": "npm:^2.8.0" "@trivago/prettier-plugin-sort-imports": "npm:^4.3.0" - formidable: "npm:^3.5.1" + formidable: "npm:^3.5.2" itty-router: "npm:^5.0.18" prettier: "npm:^3.3.3" languageName: unknown From f60c692d594eec016133ad6bd331133f1b8571c8 Mon Sep 17 00:00:00 2001 From: proddy Date: Sat, 19 Oct 2024 12:14:59 +0200 Subject: [PATCH 2/2] update dumps --- dump_entities.csv | 4491 ++++++++++++----------- dump_telegrams.csv | 2 +- scripts/generate-modbus-register-doc.py | 1 - scripts/generate-modbus-register-doc.sh | 1 - scripts/update_modbus_registers.sh | 31 +- 5 files changed, 2277 insertions(+), 2249 deletions(-) diff --git a/dump_entities.csv b/dump_entities.csv index 7fc21cbe6..62bdca251 100644 --- a/dump_entities.csv +++ b/dump_entities.csv @@ -1,207 +1,209 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/max),uom,writeable,discovery entityid v3.4,discovery entityid,modbus unit identifier,modbus block,modbus scale factor,modbus offset,modbus count -CS5800i/CS6800i/WLW1x6i,boiler,8,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28 -CS5800i/CS6800i/WLW1x6i,boiler,8,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6 -CS5800i/CS6800i/WLW1x6i,boiler,8,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,nrg,energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_energy,sensor.boiler_dhw_nrg,5,9,1/100,0,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_energy_heating,sensor.boiler_nrgheat,5,0,1/100,82,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,nrgcool,energy cooling,uint24 (>=0<=167772),kWh,false,sensor.boiler_energy_cooling,sensor.boiler_nrgcool,5,0,1/100,264,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_total,sensor.boiler_metertotal,5,0,1/100,84,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_compressor,sensor.boiler_metercomp,5,0,1/100,86,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_e-heater,sensor.boiler_metereheat,5,0,1/100,88,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/100,90,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,metercool,meter cooling,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_cooling,sensor.boiler_metercool,5,0,1/100,266,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,meter,meter,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/100,2,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,uptimetotal,heatpump total uptime,time (>=0<=279620),minutes,false,sensor.boiler_heatpump_total_uptime,sensor.boiler_uptimetotal,5,0,1/60,92,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,uptimecontrol,total operating time heat,time (>=0<=279620),minutes,false,sensor.boiler_total_operating_time_heat,sensor.boiler_uptimecontrol,5,0,1/60,94,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,uptimecompheating,operating time compressor heating,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_heating,sensor.boiler_uptimecompheating,5,0,1/60,96,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,uptimecompcooling,operating time compressor cooling,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_cooling,sensor.boiler_uptimecompcooling,5,0,1/60,98,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,uptimecomp,operating time compressor,time (>=0<=279620),minutes,false,sensor.boiler_dhw_operating_time_compressor,sensor.boiler_dhw_uptimecomp,5,9,1/60,4,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,uptimecomppool,operating time compressor pool,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_pool,sensor.boiler_uptimecomppool,5,0,1/60,100,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,totalcompstarts,total compressor control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts,5,0,1,102,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,heatingstarts,heating control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts,5,0,1,104,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,coolingstarts,cooling control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_cooling_control_starts,sensor.boiler_coolingstarts,5,0,1,106,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,starts2,control starts2,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_control_starts2,sensor.boiler_dhw_starts2,5,9,1,6,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,poolstarts,pool control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_pool_control_starts,sensor.boiler_poolstarts,5,0,1,108,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,nrgconstotal,total energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal,5,0,1,110,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,nrgconscomptotal,total energy consumption compressor,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal,5,0,1,112,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,nrgconscompheating,energy consumption compressor heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating,5,0,1,114,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,nrgconscomp,energy consumption compressor,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_energy_consumption_compressor,sensor.boiler_dhw_nrgconscomp,5,9,1,8,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,nrgconscompcooling,energy consumption compressor cooling,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling,5,0,1,116,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,nrgconscomppool,energy consumption compressor pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool,5,0,1,118,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,auxelecheatnrgconstotal,total aux elec. heater energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal,5,0,1,120,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating,5,0,1,122,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,auxelecheatnrgcons,aux elec. heater energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_aux_elec._heater_energy_consumption,sensor.boiler_dhw_auxelecheatnrgcons,5,9,1,10,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,auxelecheatnrgconspool,aux elec. heater energy consumption pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool,5,0,1,124,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,nrgsupptotal,total energy supplied,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal,5,0,1,126,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,nrgsuppheating,total energy supplied heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating,5,0,1,128,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,nrgsupp,total energy warm supplied,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_total_energy_warm_supplied,sensor.boiler_dhw_nrgsupp,5,9,1,12,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,nrgsuppcooling,total energy supplied cooling,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling,5,0,1,130,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,nrgsupppool,total energy supplied pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool,5,0,1,132,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,hppower,compressor power output,uint8 (>=0<=25),kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower,5,0,1/10,134,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hpmaxpower,compressor max power,uint8 (>=0<=100),%,true,number.boiler_compressor_max_power,number.boiler_hpmaxpower,5,0,1,135,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hpsetdiffpress,set differental pressure,uint8 (>=150<=750),mbar,true,number.boiler_set_differental_pressure,number.boiler_hpsetdiffpress,5,0,50,136,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hpcompon,hp compressor,boolean, ,false,binary_sensor.boiler_hp_compressor,binary_sensor.boiler_hpcompon,5,0,1,137,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hpactivity,compressor activity,enum [none\|heating\|cooling\|hot water\|pool\|unknown\|defrost], ,false,sensor.boiler_compressor_activity,sensor.boiler_hpactivity,5,0,1,138,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hpbrinepumpspd,brine pump speed,uint8 (>=0<=100),%,false,sensor.boiler_brine_pump_speed,sensor.boiler_hpbrinepumpspd,5,0,1,139,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hpswitchvalve,switch valve,boolean, ,false,binary_sensor.boiler_switch_valve,binary_sensor.boiler_hpswitchvalve,5,0,1,140,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hpcompspd,compressor speed,uint8 (>=0<=100),%,false,sensor.boiler_compressor_speed,sensor.boiler_hpcompspd,5,0,1,141,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hpcircspd,circulation pump speed,uint8 (>=0<=100),%,false,sensor.boiler_circulation_pump_speed,sensor.boiler_hpcircspd,5,0,1,142,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hpbrinein,brine in/evaporator,int16 (>=-3199<=3199),C,false,sensor.boiler_brine_in/evaporator,sensor.boiler_hpbrinein,5,0,1/10,143,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hpbrineout,brine out/condenser,int16 (>=-3199<=3199),C,false,sensor.boiler_brine_out/condenser,sensor.boiler_hpbrineout,5,0,1/10,144,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hptc0,heat carrier return (TC0),int16 (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_return_(TC0),sensor.boiler_hptc0,5,0,1/10,145,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hptc1,heat carrier forward (TC1),int16 (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_forward_(TC1),sensor.boiler_hptc1,5,0,1/10,146,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hptc3,condenser temperature (TC3),int16 (>=-3199<=3199),C,false,sensor.boiler_condenser_temperature_(TC3),sensor.boiler_hptc3,5,0,1/10,147,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hptr1,compressor temperature (TR1),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_temperature_(TR1),sensor.boiler_hptr1,5,0,1/10,148,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hptr3,refrigerant temperature liquid side (condenser output) (TR3),int16 (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.boiler_hptr3,5,0,1/10,149,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hptr4,evaporator inlet temperature (TR4),int16 (>=-3199<=3199),C,false,sensor.boiler_evaporator_inlet_temperature_(TR4),sensor.boiler_hptr4,5,0,1/10,150,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hptr5,compressor inlet temperature (TR5),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_inlet_temperature_(TR5),sensor.boiler_hptr5,5,0,1/10,151,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hptr6,compressor outlet temperature (TR6),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_outlet_temperature_(TR6),sensor.boiler_hptr6,5,0,1/10,152,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hptr7,refrigerant temperature gas side (condenser input) (TR7),int16 (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7),sensor.boiler_hptr7,5,0,1/10,153,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hptl2,air inlet temperature (TL2),int16 (>=-3199<=3199),C,false,sensor.boiler_air_inlet_temperature_(TL2),sensor.boiler_hptl2,5,0,1/10,154,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hppl1,low pressure side temperature (PL1),int16 (>=-3199<=3199),C,false,sensor.boiler_low_pressure_side_temperature_(PL1),sensor.boiler_hppl1,5,0,1/10,155,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hpph1,high pressure side temperature (PH1),int16 (>=-3199<=3199),C,false,sensor.boiler_high_pressure_side_temperature_(PH1),sensor.boiler_hpph1,5,0,1/10,156,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hpta4,drain pan temp (TA4),int16 (>=-3199<=3199),C,false,sensor.boiler_drain_pan_temp_(TA4),sensor.boiler_hpta4,5,0,1/10,157,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hptw1,reservoir temp (TW1),int16 (>=-3199<=3199),C,false,sensor.boiler_reservoir_temp_(TW1),sensor.boiler_hptw1,5,0,1/10,158,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,poolsettemp,pool set temperature,uint8 (>=0<=127),C,true,number.boiler_pool_set_temperature,number.boiler_poolsettemp,5,0,1/2,159,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hp4way,4-way valve (VR4),enum [cooling & defrost\|heating & dhw], ,false,sensor.boiler_4-way_valve_(VR4),sensor.boiler_hp4way,5,0,1,160,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hpin1,input 1 state,boolean, ,false,binary_sensor.boiler_input_1_state,binary_sensor.boiler_hpin1,5,0,1,161,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hpin1opt,input 1 options,string, ,true,sensor.boiler_input_1_options,sensor.boiler_hpin1opt,5,0,1,162,8 -CS5800i/CS6800i/WLW1x6i,boiler,8,hpin2,input 2 state,boolean, ,false,binary_sensor.boiler_input_2_state,binary_sensor.boiler_hpin2,5,0,1,170,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hpin2opt,input 2 options,string, ,true,sensor.boiler_input_2_options,sensor.boiler_hpin2opt,5,0,1,171,8 -CS5800i/CS6800i/WLW1x6i,boiler,8,hpin3,input 3 state,boolean, ,false,binary_sensor.boiler_input_3_state,binary_sensor.boiler_hpin3,5,0,1,179,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hpin3opt,input 3 options,string, ,true,sensor.boiler_input_3_options,sensor.boiler_hpin3opt,5,0,1,180,8 -CS5800i/CS6800i/WLW1x6i,boiler,8,hpin4,input 4 state,boolean, ,false,binary_sensor.boiler_input_4_state,binary_sensor.boiler_hpin4,5,0,1,188,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hpin4opt,input 4 options,string, ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt,5,0,1,189,8 -CS5800i/CS6800i/WLW1x6i,boiler,8,maxheatcomp,heat limit compressor,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp,5,0,1,197,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,maxheatheat,heat limit heating,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat,5,0,1,198,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,maxheat,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_dhw_heat_limit,select.boiler_dhw_maxheat,5,9,1,14,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,mandefrost,manual defrost,boolean, ,true,switch.boiler_manual_defrost,switch.boiler_mandefrost,5,0,1,199,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,pvcooling,cooling only with PV,boolean, ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling,5,0,1,200,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,auxheateronly,aux heater only,boolean, ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly,5,0,1,201,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,auxheateroff,disable aux heater,boolean, ,true,switch.boiler_disable_aux_heater,switch.boiler_auxheateroff,5,0,1,202,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,auxheaterstatus,aux heater status,uint8 (>=0<=100),%,false,sensor.boiler_aux_heater_status,sensor.boiler_auxheaterstatus,5,0,1,203,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,auxheaterdelay,aux heater on delay,uint16 (>=10<=1000),K*min,true,number.boiler_aux_heater_on_delay,number.boiler_auxheaterdelay,5,0,10,204,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,auxmaxlimit,aux heater max limit,uint8 (>=0<=10),K,true,number.boiler_aux_heater_max_limit,number.boiler_auxmaxlimit,5,0,1/10,205,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,auxlimitstart,aux heater limit start,uint8 (>=0<=10),K,true,number.boiler_aux_heater_limit_start,number.boiler_auxlimitstart,5,0,1/10,206,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,auxheatrmode,aux heater mode,enum [eco\|comfort], ,true,select.boiler_aux_heater_mode,select.boiler_auxheatrmode,5,0,1,207,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hphystheat,on/off hyst heat,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_heat,number.boiler_hphystheat,5,0,5,208,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hphystcool,on/off hyst cool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_cool,number.boiler_hphystcool,5,0,5,209,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hphystpool,on/off hyst pool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_pool,number.boiler_hphystpool,5,0,5,210,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,silentmode,silent mode,enum [off\|auto\|on], ,true,select.boiler_silent_mode,select.boiler_silentmode,5,0,1,211,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,silentfrom,silent mode from,uint8 (>=0<=3810),minutes,true,number.boiler_silent_mode_from,number.boiler_silentfrom,5,0,15,212,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,silentto,silent mode to,uint8 (>=0<=3810),minutes,true,number.boiler_silent_mode_to,number.boiler_silentto,5,0,15,213,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,mintempsilent,min outside temp for silent mode,int8 (>=-126<=126),C,true,number.boiler_min_outside_temp_for_silent_mode,number.boiler_mintempsilent,5,0,1,214,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,tempparmode,outside temp parallel mode,int8 (>=-126<=126),C,true,number.boiler_outside_temp_parallel_mode,number.boiler_tempparmode,5,0,1,215,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,auxheatmix,aux heater mixing valve,int8 (>=-100<=100),%,false,sensor.boiler_aux_heater_mixing_valve,sensor.boiler_auxheatmix,5,0,1,216,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,tempdiffheat,temp diff TC3/TC0 heat,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_heat,number.boiler_tempdiffheat,5,0,1/10,217,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,tempdiffcool,temp diff TC3/TC0 cool,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_cool,number.boiler_tempdiffcool,5,0,1/10,218,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,vpcooling,valve/pump cooling,boolean, ,true,switch.boiler_valve/pump_cooling,switch.boiler_vpcooling,5,0,1,219,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,heatcable,heating cable,boolean, ,true,switch.boiler_heating_cable,switch.boiler_heatcable,5,0,1,220,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,vc0valve,VC0 valve,boolean, ,true,switch.boiler_VC0_valve,switch.boiler_vc0valve,5,0,1,221,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,primepump,primary heatpump,boolean, ,true,switch.boiler_primary_heatpump,switch.boiler_primepump,5,0,1,222,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,primepumpmod,primary heatpump modulation,uint8 (>=0<=100),%,true,number.boiler_primary_heatpump_modulation,number.boiler_primepumpmod,5,0,1,223,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hp3way,3-way valve,boolean, ,true,switch.boiler_3-way_valve,switch.boiler_hp3way,5,0,1,224,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,elheatstep1,el. heater step 1,boolean, ,true,switch.boiler_el._heater_step_1,switch.boiler_elheatstep1,5,0,1,225,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,elheatstep2,el. heater step 2,boolean, ,true,switch.boiler_el._heater_step_2,switch.boiler_elheatstep2,5,0,1,226,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,elheatstep3,el. heater step 3,boolean, ,true,switch.boiler_el._heater_step_3,switch.boiler_elheatstep3,5,0,1,227,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hpea0,condensate reservoir heating (EA0),boolean, ,false,binary_sensor.boiler_condensate_reservoir_heating_(EA0),binary_sensor.boiler_hpea0,5,0,1,228,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hppumpmode,primary heatpump mode,enum [auto\|continuous], ,true,select.boiler_primary_heatpump_mode,select.boiler_hppumpmode,5,0,1,229,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,fan,fan,uint8 (>=20<=100),%,true,number.boiler_fan,number.boiler_fan,5,0,1,230,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,shutdown,shutdown,cmd [off\|on], ,true,sensor.boiler_shutdown,sensor.boiler_shutdown,5,0,1,231,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hpcurrpower,compressor current power,uint16 (>=0<=31999),W,false,sensor.boiler_compressor_current_power,sensor.boiler_hpcurrpower,5,0,1,268,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hppowerlimit,power limit,uint16 (>=0<=31999),W,true,number.boiler_power_limit,number.boiler_hppowerlimit,5,0,1,269,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,pc0flow,Flow PC0,int16 (>=-31999<=31999),l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,5,0,1,270,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,pc1flow,Flow PC1,int16 (>=-31999<=31999),l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,5,0,1,271,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,5,0,1,272,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,pc1rate,PC1 rate,uint8 (>=0<=100),%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,5,0,1,273,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,alternatingop,alternating operation,boolean, ,true,switch.boiler_dhw_alternating_operation,switch.boiler_dhw_alternatingop,5,9,1,15,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,altopprioheat,prioritise heating during dhw,uint8 (>=20<=120),minutes,true,number.boiler_dhw_prioritise_heating_during_dhw,number.boiler_dhw_altopprioheat,5,9,1,16,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,altopprio,prioritise dhw during heating,uint8 (>=30<=120),minutes,true,number.boiler_dhw_prioritise_dhw_during_heating,number.boiler_dhw_altopprio,5,9,1,17,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,comfoff,comfort switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_comfort_switch_off,number.boiler_dhw_comfoff,5,9,1,18,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,ecooff,eco switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_eco_switch_off,number.boiler_dhw_ecooff,5,9,1,19,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,ecoplusoff,eco+ switch off,uint8 (>=48<=63),C,true,number.boiler_dhw_eco+_switch_off,number.boiler_dhw_ecoplusoff,5,9,1,20,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,comfdiff,comfort diff,uint8 (>=6<=12),K,true,number.boiler_dhw_comfort_diff,number.boiler_dhw_comfdiff,5,9,1,21,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,ecodiff,eco diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco_diff,number.boiler_dhw_ecodiff,5,9,1,22,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,ecoplusdiff,eco+ diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco+_diff,number.boiler_dhw_ecoplusdiff,5,9,1,23,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,comfstop,comfort stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_comfort_stop_temp,number.boiler_dhw_comfstop,5,9,1,24,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,ecostop,eco stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco_stop_temp,number.boiler_dhw_ecostop,5,9,1,25,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,ecoplusstop,eco+ stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco+_stop_temp,number.boiler_dhw_ecoplusstop,5,9,1,26,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hpcircpump,circulation pump available during dhw,boolean, ,true,switch.boiler_dhw_circulation_pump_available_during_dhw,switch.boiler_dhw_hpcircpump,5,9,1,27,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 -CS5800i/CS6800i/WLW1x6i,boiler,8,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 -CS5800i/CS6800i/WLW1x6i,boiler,8,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 +CS*800i, Logatherm WLW*,boiler,8,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 +CS*800i, Logatherm WLW*,boiler,8,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 +CS*800i, Logatherm WLW*,boiler,8,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 +CS*800i, Logatherm WLW*,boiler,8,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 +CS*800i, Logatherm WLW*,boiler,8,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 +CS*800i, Logatherm WLW*,boiler,8,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 +CS*800i, Logatherm WLW*,boiler,8,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 +CS*800i, Logatherm WLW*,boiler,8,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 +CS*800i, Logatherm WLW*,boiler,8,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 +CS*800i, Logatherm WLW*,boiler,8,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 +CS*800i, Logatherm WLW*,boiler,8,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 +CS*800i, Logatherm WLW*,boiler,8,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 +CS*800i, Logatherm WLW*,boiler,8,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 +CS*800i, Logatherm WLW*,boiler,8,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 +CS*800i, Logatherm WLW*,boiler,8,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 +CS*800i, Logatherm WLW*,boiler,8,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 +CS*800i, Logatherm WLW*,boiler,8,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 +CS*800i, Logatherm WLW*,boiler,8,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 +CS*800i, Logatherm WLW*,boiler,8,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 +CS*800i, Logatherm WLW*,boiler,8,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 +CS*800i, Logatherm WLW*,boiler,8,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 +CS*800i, Logatherm WLW*,boiler,8,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1 +CS*800i, Logatherm WLW*,boiler,8,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 +CS*800i, Logatherm WLW*,boiler,8,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 +CS*800i, Logatherm WLW*,boiler,8,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 +CS*800i, Logatherm WLW*,boiler,8,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2 +CS*800i, Logatherm WLW*,boiler,8,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2 +CS*800i, Logatherm WLW*,boiler,8,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2 +CS*800i, Logatherm WLW*,boiler,8,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2 +CS*800i, Logatherm WLW*,boiler,8,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2 +CS*800i, Logatherm WLW*,boiler,8,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28 +CS*800i, Logatherm WLW*,boiler,8,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2 +CS*800i, Logatherm WLW*,boiler,8,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1 +CS*800i, Logatherm WLW*,boiler,8,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2 +CS*800i, Logatherm WLW*,boiler,8,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1 +CS*800i, Logatherm WLW*,boiler,8,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1 +CS*800i, Logatherm WLW*,boiler,8,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6 +CS*800i, Logatherm WLW*,boiler,8,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1 +CS*800i, Logatherm WLW*,boiler,8,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1 +CS*800i, Logatherm WLW*,boiler,8,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 +CS*800i, Logatherm WLW*,boiler,8,nrg,energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_energy,sensor.boiler_dhw_nrg,5,9,1/100,0,2 +CS*800i, Logatherm WLW*,boiler,8,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_energy_heating,sensor.boiler_nrgheat,5,0,1/100,82,2 +CS*800i, Logatherm WLW*,boiler,8,nrgcool,energy cooling,uint24 (>=0<=167772),kWh,false,sensor.boiler_energy_cooling,sensor.boiler_nrgcool,5,0,1/100,264,2 +CS*800i, Logatherm WLW*,boiler,8,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_total,sensor.boiler_metertotal,5,0,1/100,84,2 +CS*800i, Logatherm WLW*,boiler,8,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_compressor,sensor.boiler_metercomp,5,0,1/100,86,2 +CS*800i, Logatherm WLW*,boiler,8,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_e-heater,sensor.boiler_metereheat,5,0,1/100,88,2 +CS*800i, Logatherm WLW*,boiler,8,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/100,90,2 +CS*800i, Logatherm WLW*,boiler,8,metercool,meter cooling,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_cooling,sensor.boiler_metercool,5,0,1/100,266,2 +CS*800i, Logatherm WLW*,boiler,8,meter,meter,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/100,2,2 +CS*800i, Logatherm WLW*,boiler,8,uptimetotal,heatpump total uptime,time (>=0<=279620),minutes,false,sensor.boiler_heatpump_total_uptime,sensor.boiler_uptimetotal,5,0,1/60,92,2 +CS*800i, Logatherm WLW*,boiler,8,uptimecontrol,total operating time heat,time (>=0<=279620),minutes,false,sensor.boiler_total_operating_time_heat,sensor.boiler_uptimecontrol,5,0,1/60,94,2 +CS*800i, Logatherm WLW*,boiler,8,uptimecompheating,operating time compressor heating,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_heating,sensor.boiler_uptimecompheating,5,0,1/60,96,2 +CS*800i, Logatherm WLW*,boiler,8,uptimecompcooling,operating time compressor cooling,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_cooling,sensor.boiler_uptimecompcooling,5,0,1/60,98,2 +CS*800i, Logatherm WLW*,boiler,8,uptimecomp,operating time compressor,time (>=0<=279620),minutes,false,sensor.boiler_dhw_operating_time_compressor,sensor.boiler_dhw_uptimecomp,5,9,1/60,4,2 +CS*800i, Logatherm WLW*,boiler,8,uptimecomppool,operating time compressor pool,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_pool,sensor.boiler_uptimecomppool,5,0,1/60,100,2 +CS*800i, Logatherm WLW*,boiler,8,totalcompstarts,total compressor control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts,5,0,1,102,2 +CS*800i, Logatherm WLW*,boiler,8,heatingstarts,heating control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts,5,0,1,104,2 +CS*800i, Logatherm WLW*,boiler,8,coolingstarts,cooling control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_cooling_control_starts,sensor.boiler_coolingstarts,5,0,1,106,2 +CS*800i, Logatherm WLW*,boiler,8,starts2,control starts2,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_control_starts2,sensor.boiler_dhw_starts2,5,9,1,6,2 +CS*800i, Logatherm WLW*,boiler,8,poolstarts,pool control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_pool_control_starts,sensor.boiler_poolstarts,5,0,1,108,2 +CS*800i, Logatherm WLW*,boiler,8,nrgconstotal,total energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal,5,0,1,110,2 +CS*800i, Logatherm WLW*,boiler,8,nrgconscomptotal,total energy consumption compressor,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal,5,0,1,112,2 +CS*800i, Logatherm WLW*,boiler,8,nrgconscompheating,energy consumption compressor heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating,5,0,1,114,2 +CS*800i, Logatherm WLW*,boiler,8,nrgconscomp,energy consumption compressor,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_energy_consumption_compressor,sensor.boiler_dhw_nrgconscomp,5,9,1,8,2 +CS*800i, Logatherm WLW*,boiler,8,nrgconscompcooling,energy consumption compressor cooling,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling,5,0,1,116,2 +CS*800i, Logatherm WLW*,boiler,8,nrgconscomppool,energy consumption compressor pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool,5,0,1,118,2 +CS*800i, Logatherm WLW*,boiler,8,auxelecheatnrgconstotal,total aux elec. heater energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal,5,0,1,120,2 +CS*800i, Logatherm WLW*,boiler,8,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating,5,0,1,122,2 +CS*800i, Logatherm WLW*,boiler,8,auxelecheatnrgcons,aux elec. heater energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_aux_elec._heater_energy_consumption,sensor.boiler_dhw_auxelecheatnrgcons,5,9,1,10,2 +CS*800i, Logatherm WLW*,boiler,8,auxelecheatnrgconspool,aux elec. heater energy consumption pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool,5,0,1,124,2 +CS*800i, Logatherm WLW*,boiler,8,nrgsupptotal,total energy supplied,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal,5,0,1,126,2 +CS*800i, Logatherm WLW*,boiler,8,nrgsuppheating,total energy supplied heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating,5,0,1,128,2 +CS*800i, Logatherm WLW*,boiler,8,nrgsupp,total energy warm supplied,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_total_energy_warm_supplied,sensor.boiler_dhw_nrgsupp,5,9,1,12,2 +CS*800i, Logatherm WLW*,boiler,8,nrgsuppcooling,total energy supplied cooling,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling,5,0,1,130,2 +CS*800i, Logatherm WLW*,boiler,8,nrgsupppool,total energy supplied pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool,5,0,1,132,2 +CS*800i, Logatherm WLW*,boiler,8,hppower,compressor power output,uint8 (>=0<=25),kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower,5,0,1/10,134,1 +CS*800i, Logatherm WLW*,boiler,8,hpmaxpower,compressor max power,uint8 (>=0<=100),%,true,number.boiler_compressor_max_power,number.boiler_hpmaxpower,5,0,1,135,1 +CS*800i, Logatherm WLW*,boiler,8,pvmaxcomp,pv compressor max power,uint8 (>=0<=25),kW,true,number.boiler_pv_compressor_max_power,number.boiler_pvmaxcomp,5,0,1/10,-1,1 +CS*800i, Logatherm WLW*,boiler,8,hpsetdiffpress,set differental pressure,uint8 (>=150<=750),mbar,true,number.boiler_set_differental_pressure,number.boiler_hpsetdiffpress,5,0,50,136,1 +CS*800i, Logatherm WLW*,boiler,8,hpcompon,hp compressor,boolean, ,false,binary_sensor.boiler_hp_compressor,binary_sensor.boiler_hpcompon,5,0,1,137,1 +CS*800i, Logatherm WLW*,boiler,8,hpactivity,compressor activity,enum [none\|heating\|cooling\|hot water\|pool\|unknown\|defrost], ,false,sensor.boiler_compressor_activity,sensor.boiler_hpactivity,5,0,1,138,1 +CS*800i, Logatherm WLW*,boiler,8,hpbrinepumpspd,brine pump speed,uint8 (>=0<=100),%,false,sensor.boiler_brine_pump_speed,sensor.boiler_hpbrinepumpspd,5,0,1,139,1 +CS*800i, Logatherm WLW*,boiler,8,hpswitchvalve,switch valve,boolean, ,false,binary_sensor.boiler_switch_valve,binary_sensor.boiler_hpswitchvalve,5,0,1,140,1 +CS*800i, Logatherm WLW*,boiler,8,hpcompspd,compressor speed,uint8 (>=0<=100),%,false,sensor.boiler_compressor_speed,sensor.boiler_hpcompspd,5,0,1,141,1 +CS*800i, Logatherm WLW*,boiler,8,hpcircspd,circulation pump speed,uint8 (>=0<=100),%,false,sensor.boiler_circulation_pump_speed,sensor.boiler_hpcircspd,5,0,1,142,1 +CS*800i, Logatherm WLW*,boiler,8,hpbrinein,brine in/evaporator,int16 (>=-3199<=3199),C,false,sensor.boiler_brine_in/evaporator,sensor.boiler_hpbrinein,5,0,1/10,143,1 +CS*800i, Logatherm WLW*,boiler,8,hpbrineout,brine out/condenser,int16 (>=-3199<=3199),C,false,sensor.boiler_brine_out/condenser,sensor.boiler_hpbrineout,5,0,1/10,144,1 +CS*800i, Logatherm WLW*,boiler,8,hptc0,heat carrier return (TC0),int16 (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_return_(TC0),sensor.boiler_hptc0,5,0,1/10,145,1 +CS*800i, Logatherm WLW*,boiler,8,hptc1,heat carrier forward (TC1),int16 (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_forward_(TC1),sensor.boiler_hptc1,5,0,1/10,146,1 +CS*800i, Logatherm WLW*,boiler,8,hptc3,condenser temperature (TC3),int16 (>=-3199<=3199),C,false,sensor.boiler_condenser_temperature_(TC3),sensor.boiler_hptc3,5,0,1/10,147,1 +CS*800i, Logatherm WLW*,boiler,8,hptr1,compressor temperature (TR1),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_temperature_(TR1),sensor.boiler_hptr1,5,0,1/10,148,1 +CS*800i, Logatherm WLW*,boiler,8,hptr3,refrigerant temperature liquid side (condenser output) (TR3),int16 (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.boiler_hptr3,5,0,1/10,149,1 +CS*800i, Logatherm WLW*,boiler,8,hptr4,evaporator inlet temperature (TR4),int16 (>=-3199<=3199),C,false,sensor.boiler_evaporator_inlet_temperature_(TR4),sensor.boiler_hptr4,5,0,1/10,150,1 +CS*800i, Logatherm WLW*,boiler,8,hptr5,compressor inlet temperature (TR5),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_inlet_temperature_(TR5),sensor.boiler_hptr5,5,0,1/10,151,1 +CS*800i, Logatherm WLW*,boiler,8,hptr6,compressor outlet temperature (TR6),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_outlet_temperature_(TR6),sensor.boiler_hptr6,5,0,1/10,152,1 +CS*800i, Logatherm WLW*,boiler,8,hptr7,refrigerant temperature gas side (condenser input) (TR7),int16 (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7),sensor.boiler_hptr7,5,0,1/10,153,1 +CS*800i, Logatherm WLW*,boiler,8,hptl2,air inlet temperature (TL2),int16 (>=-3199<=3199),C,false,sensor.boiler_air_inlet_temperature_(TL2),sensor.boiler_hptl2,5,0,1/10,154,1 +CS*800i, Logatherm WLW*,boiler,8,hppl1,low pressure side temperature (PL1),int16 (>=-3199<=3199),C,false,sensor.boiler_low_pressure_side_temperature_(PL1),sensor.boiler_hppl1,5,0,1/10,155,1 +CS*800i, Logatherm WLW*,boiler,8,hpph1,high pressure side temperature (PH1),int16 (>=-3199<=3199),C,false,sensor.boiler_high_pressure_side_temperature_(PH1),sensor.boiler_hpph1,5,0,1/10,156,1 +CS*800i, Logatherm WLW*,boiler,8,hpta4,drain pan temp (TA4),int16 (>=-3199<=3199),C,false,sensor.boiler_drain_pan_temp_(TA4),sensor.boiler_hpta4,5,0,1/10,157,1 +CS*800i, Logatherm WLW*,boiler,8,hptw1,reservoir temp (TW1),int16 (>=-3199<=3199),C,false,sensor.boiler_reservoir_temp_(TW1),sensor.boiler_hptw1,5,0,1/10,158,1 +CS*800i, Logatherm WLW*,boiler,8,poolsettemp,pool set temperature,uint8 (>=0<=127),C,true,number.boiler_pool_set_temperature,number.boiler_poolsettemp,5,0,1/2,159,1 +CS*800i, Logatherm WLW*,boiler,8,hp4way,4-way valve (VR4),enum [cooling & defrost\|heating & dhw], ,false,sensor.boiler_4-way_valve_(VR4),sensor.boiler_hp4way,5,0,1,160,1 +CS*800i, Logatherm WLW*,boiler,8,hpin1,input 1 state,boolean, ,false,binary_sensor.boiler_input_1_state,binary_sensor.boiler_hpin1,5,0,1,161,1 +CS*800i, Logatherm WLW*,boiler,8,hpin1opt,input 1 options,string, ,true,sensor.boiler_input_1_options,sensor.boiler_hpin1opt,5,0,1,162,8 +CS*800i, Logatherm WLW*,boiler,8,hpin2,input 2 state,boolean, ,false,binary_sensor.boiler_input_2_state,binary_sensor.boiler_hpin2,5,0,1,170,1 +CS*800i, Logatherm WLW*,boiler,8,hpin2opt,input 2 options,string, ,true,sensor.boiler_input_2_options,sensor.boiler_hpin2opt,5,0,1,171,8 +CS*800i, Logatherm WLW*,boiler,8,hpin3,input 3 state,boolean, ,false,binary_sensor.boiler_input_3_state,binary_sensor.boiler_hpin3,5,0,1,179,1 +CS*800i, Logatherm WLW*,boiler,8,hpin3opt,input 3 options,string, ,true,sensor.boiler_input_3_options,sensor.boiler_hpin3opt,5,0,1,180,8 +CS*800i, Logatherm WLW*,boiler,8,hpin4,input 4 state,boolean, ,false,binary_sensor.boiler_input_4_state,binary_sensor.boiler_hpin4,5,0,1,188,1 +CS*800i, Logatherm WLW*,boiler,8,hpin4opt,input 4 options,string, ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt,5,0,1,189,8 +CS*800i, Logatherm WLW*,boiler,8,maxheatcomp,heat limit compressor,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp,5,0,1,197,1 +CS*800i, Logatherm WLW*,boiler,8,maxheatheat,heat limit heating,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat,5,0,1,198,1 +CS*800i, Logatherm WLW*,boiler,8,maxheat,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_dhw_heat_limit,select.boiler_dhw_maxheat,5,9,1,14,1 +CS*800i, Logatherm WLW*,boiler,8,mandefrost,manual defrost,boolean, ,true,switch.boiler_manual_defrost,switch.boiler_mandefrost,5,0,1,199,1 +CS*800i, Logatherm WLW*,boiler,8,pvcooling,cooling only with PV,boolean, ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling,5,0,1,200,1 +CS*800i, Logatherm WLW*,boiler,8,auxheateronly,aux heater only,boolean, ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly,5,0,1,201,1 +CS*800i, Logatherm WLW*,boiler,8,auxheateroff,disable aux heater,boolean, ,true,switch.boiler_disable_aux_heater,switch.boiler_auxheateroff,5,0,1,202,1 +CS*800i, Logatherm WLW*,boiler,8,auxheaterstatus,aux heater status,uint8 (>=0<=100),%,false,sensor.boiler_aux_heater_status,sensor.boiler_auxheaterstatus,5,0,1,203,1 +CS*800i, Logatherm WLW*,boiler,8,auxheaterdelay,aux heater on delay,uint16 (>=10<=1000),K*min,true,number.boiler_aux_heater_on_delay,number.boiler_auxheaterdelay,5,0,10,204,1 +CS*800i, Logatherm WLW*,boiler,8,auxmaxlimit,aux heater max limit,uint8 (>=0<=10),K,true,number.boiler_aux_heater_max_limit,number.boiler_auxmaxlimit,5,0,1/10,205,1 +CS*800i, Logatherm WLW*,boiler,8,auxlimitstart,aux heater limit start,uint8 (>=0<=10),K,true,number.boiler_aux_heater_limit_start,number.boiler_auxlimitstart,5,0,1/10,206,1 +CS*800i, Logatherm WLW*,boiler,8,auxheatrmode,aux heater mode,enum [eco\|comfort], ,true,select.boiler_aux_heater_mode,select.boiler_auxheatrmode,5,0,1,207,1 +CS*800i, Logatherm WLW*,boiler,8,hphystheat,on/off hyst heat,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_heat,number.boiler_hphystheat,5,0,5,208,1 +CS*800i, Logatherm WLW*,boiler,8,hphystcool,on/off hyst cool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_cool,number.boiler_hphystcool,5,0,5,209,1 +CS*800i, Logatherm WLW*,boiler,8,hphystpool,on/off hyst pool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_pool,number.boiler_hphystpool,5,0,5,210,1 +CS*800i, Logatherm WLW*,boiler,8,silentmode,silent mode,enum [off\|auto\|on], ,true,select.boiler_silent_mode,select.boiler_silentmode,5,0,1,211,1 +CS*800i, Logatherm WLW*,boiler,8,silentfrom,silent mode from,uint8 (>=0<=3810),minutes,true,number.boiler_silent_mode_from,number.boiler_silentfrom,5,0,15,212,1 +CS*800i, Logatherm WLW*,boiler,8,silentto,silent mode to,uint8 (>=0<=3810),minutes,true,number.boiler_silent_mode_to,number.boiler_silentto,5,0,15,213,1 +CS*800i, Logatherm WLW*,boiler,8,mintempsilent,min outside temp for silent mode,int8 (>=-126<=126),C,true,number.boiler_min_outside_temp_for_silent_mode,number.boiler_mintempsilent,5,0,1,214,1 +CS*800i, Logatherm WLW*,boiler,8,tempparmode,outside temp parallel mode,int8 (>=-126<=126),C,true,number.boiler_outside_temp_parallel_mode,number.boiler_tempparmode,5,0,1,215,1 +CS*800i, Logatherm WLW*,boiler,8,auxheatmix,aux heater mixing valve,int8 (>=-100<=100),%,false,sensor.boiler_aux_heater_mixing_valve,sensor.boiler_auxheatmix,5,0,1,216,1 +CS*800i, Logatherm WLW*,boiler,8,tempdiffheat,temp diff TC3/TC0 heat,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_heat,number.boiler_tempdiffheat,5,0,1/10,217,1 +CS*800i, Logatherm WLW*,boiler,8,tempdiffcool,temp diff TC3/TC0 cool,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_cool,number.boiler_tempdiffcool,5,0,1/10,218,1 +CS*800i, Logatherm WLW*,boiler,8,vpcooling,valve/pump cooling,boolean, ,true,switch.boiler_valve/pump_cooling,switch.boiler_vpcooling,5,0,1,219,1 +CS*800i, Logatherm WLW*,boiler,8,heatcable,heating cable,boolean, ,true,switch.boiler_heating_cable,switch.boiler_heatcable,5,0,1,220,1 +CS*800i, Logatherm WLW*,boiler,8,vc0valve,VC0 valve,boolean, ,true,switch.boiler_VC0_valve,switch.boiler_vc0valve,5,0,1,221,1 +CS*800i, Logatherm WLW*,boiler,8,primepump,primary heatpump,boolean, ,true,switch.boiler_primary_heatpump,switch.boiler_primepump,5,0,1,222,1 +CS*800i, Logatherm WLW*,boiler,8,primepumpmod,primary heatpump modulation,uint8 (>=0<=100),%,true,number.boiler_primary_heatpump_modulation,number.boiler_primepumpmod,5,0,1,223,1 +CS*800i, Logatherm WLW*,boiler,8,hp3way,3-way valve,boolean, ,true,switch.boiler_3-way_valve,switch.boiler_hp3way,5,0,1,224,1 +CS*800i, Logatherm WLW*,boiler,8,elheatstep1,el. heater step 1,boolean, ,true,switch.boiler_el._heater_step_1,switch.boiler_elheatstep1,5,0,1,225,1 +CS*800i, Logatherm WLW*,boiler,8,elheatstep2,el. heater step 2,boolean, ,true,switch.boiler_el._heater_step_2,switch.boiler_elheatstep2,5,0,1,226,1 +CS*800i, Logatherm WLW*,boiler,8,elheatstep3,el. heater step 3,boolean, ,true,switch.boiler_el._heater_step_3,switch.boiler_elheatstep3,5,0,1,227,1 +CS*800i, Logatherm WLW*,boiler,8,hpea0,condensate reservoir heating (EA0),boolean, ,false,binary_sensor.boiler_condensate_reservoir_heating_(EA0),binary_sensor.boiler_hpea0,5,0,1,228,1 +CS*800i, Logatherm WLW*,boiler,8,hppumpmode,primary heatpump mode,enum [auto\|continuous], ,true,select.boiler_primary_heatpump_mode,select.boiler_hppumpmode,5,0,1,229,1 +CS*800i, Logatherm WLW*,boiler,8,fan,fan,uint8 (>=20<=100),%,true,number.boiler_fan,number.boiler_fan,5,0,1,230,1 +CS*800i, Logatherm WLW*,boiler,8,shutdown,shutdown,cmd [off\|on], ,true,sensor.boiler_shutdown,sensor.boiler_shutdown,5,0,1,231,1 +CS*800i, Logatherm WLW*,boiler,8,hpcurrpower,compressor current power,uint16 (>=0<=31999),W,false,sensor.boiler_compressor_current_power,sensor.boiler_hpcurrpower,5,0,1,268,1 +CS*800i, Logatherm WLW*,boiler,8,hppowerlimit,power limit,uint16 (>=0<=31999),W,true,number.boiler_power_limit,number.boiler_hppowerlimit,5,0,1,269,1 +CS*800i, Logatherm WLW*,boiler,8,pc0flow,Flow PC0,int16 (>=-31999<=31999),l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,5,0,1,270,1 +CS*800i, Logatherm WLW*,boiler,8,pc1flow,Flow PC1,int16 (>=-31999<=31999),l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,5,0,1,271,1 +CS*800i, Logatherm WLW*,boiler,8,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,5,0,1,272,1 +CS*800i, Logatherm WLW*,boiler,8,pc1rate,PC1 rate,uint8 (>=0<=100),%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,5,0,1,273,1 +CS*800i, Logatherm WLW*,boiler,8,alternatingop,alternating operation,boolean, ,true,switch.boiler_dhw_alternating_operation,switch.boiler_dhw_alternatingop,5,9,1,15,1 +CS*800i, Logatherm WLW*,boiler,8,altopprioheat,prioritise heating during dhw,uint8 (>=20<=120),minutes,true,number.boiler_dhw_prioritise_heating_during_dhw,number.boiler_dhw_altopprioheat,5,9,1,16,1 +CS*800i, Logatherm WLW*,boiler,8,altopprio,prioritise dhw during heating,uint8 (>=30<=120),minutes,true,number.boiler_dhw_prioritise_dhw_during_heating,number.boiler_dhw_altopprio,5,9,1,17,1 +CS*800i, Logatherm WLW*,boiler,8,comfoff,comfort switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_comfort_switch_off,number.boiler_dhw_comfoff,5,9,1,18,1 +CS*800i, Logatherm WLW*,boiler,8,ecooff,eco switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_eco_switch_off,number.boiler_dhw_ecooff,5,9,1,19,1 +CS*800i, Logatherm WLW*,boiler,8,ecoplusoff,eco+ switch off,uint8 (>=48<=63),C,true,number.boiler_dhw_eco+_switch_off,number.boiler_dhw_ecoplusoff,5,9,1,20,1 +CS*800i, Logatherm WLW*,boiler,8,comfdiff,comfort diff,uint8 (>=6<=12),K,true,number.boiler_dhw_comfort_diff,number.boiler_dhw_comfdiff,5,9,1,21,1 +CS*800i, Logatherm WLW*,boiler,8,ecodiff,eco diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco_diff,number.boiler_dhw_ecodiff,5,9,1,22,1 +CS*800i, Logatherm WLW*,boiler,8,ecoplusdiff,eco+ diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco+_diff,number.boiler_dhw_ecoplusdiff,5,9,1,23,1 +CS*800i, Logatherm WLW*,boiler,8,comfstop,comfort stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_comfort_stop_temp,number.boiler_dhw_comfstop,5,9,1,24,1 +CS*800i, Logatherm WLW*,boiler,8,ecostop,eco stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco_stop_temp,number.boiler_dhw_ecostop,5,9,1,25,1 +CS*800i, Logatherm WLW*,boiler,8,ecoplusstop,eco+ stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco+_stop_temp,number.boiler_dhw_ecoplusstop,5,9,1,26,1 +CS*800i, Logatherm WLW*,boiler,8,hpcircpump,circulation pump available during dhw,boolean, ,true,switch.boiler_dhw_circulation_pump_available_during_dhw,switch.boiler_dhw_hpcircpump,5,9,1,27,1 +CS*800i, Logatherm WLW*,boiler,8,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 +CS*800i, Logatherm WLW*,boiler,8,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 +CS*800i, Logatherm WLW*,boiler,8,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 +CS*800i, Logatherm WLW*,boiler,8,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 +CS*800i, Logatherm WLW*,boiler,8,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 +CS*800i, Logatherm WLW*,boiler,8,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 +CS*800i, Logatherm WLW*,boiler,8,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 +CS*800i, Logatherm WLW*,boiler,8,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 +CS*800i, Logatherm WLW*,boiler,8,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 +CS*800i, Logatherm WLW*,boiler,8,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 +CS*800i, Logatherm WLW*,boiler,8,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 +CS*800i, Logatherm WLW*,boiler,8,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 +CS*800i, Logatherm WLW*,boiler,8,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 +CS*800i, Logatherm WLW*,boiler,8,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 +CS*800i, Logatherm WLW*,boiler,8,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 +CS*800i, Logatherm WLW*,boiler,8,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 +CS*800i, Logatherm WLW*,boiler,8,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 +CS*800i, Logatherm WLW*,boiler,8,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 +CS*800i, Logatherm WLW*,boiler,8,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 +CS*800i, Logatherm WLW*,boiler,8,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 +CS*800i, Logatherm WLW*,boiler,8,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 +CS*800i, Logatherm WLW*,boiler,8,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 +CS*800i, Logatherm WLW*,boiler,8,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 +CS*800i, Logatherm WLW*,boiler,8,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 +CS*800i, Logatherm WLW*,boiler,8,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 +CS*800i, Logatherm WLW*,boiler,8,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 +CS*800i, Logatherm WLW*,boiler,8,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 +CS*800i, Logatherm WLW*,boiler,8,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 +CS*800i, Logatherm WLW*,boiler,8,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 +CS*800i, Logatherm WLW*,boiler,8,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 +CS*800i, Logatherm WLW*,boiler,8,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 +CS*800i, Logatherm WLW*,boiler,8,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 +CS*800i, Logatherm WLW*,boiler,8,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 +CS*800i, Logatherm WLW*,boiler,8,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 +CS*800i, Logatherm WLW*,boiler,8,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 +CS*800i, Logatherm WLW*,boiler,8,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +CS*800i, Logatherm WLW*,boiler,8,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +CS*800i, Logatherm WLW*,boiler,8,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +CS*800i, Logatherm WLW*,boiler,8,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 C1200W,boiler,12,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 C1200W,boiler,12,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 C1200W,boiler,12,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 @@ -245,6 +247,7 @@ C1200W,boiler,12,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number C1200W,boiler,12,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 C1200W,boiler,12,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 C1200W,boiler,12,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 +C1200W,boiler,12,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1 C1200W,boiler,12,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 C1200W,boiler,12,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 C1200W,boiler,12,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 @@ -311,224 +314,226 @@ C1200W,boiler,12,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_n C1200W,boiler,12,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 C1200W,boiler,12,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2 C1200W,boiler,12,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2 -BK13/BK15/Smartline/GB1x2,boiler,64,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 -BK13/BK15/Smartline/GB1x2,boiler,64,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 -BK13/BK15/Smartline/GB1x2,boiler,64,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 -BK13/BK15/Smartline/GB1x2,boiler,64,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 -BK13/BK15/Smartline/GB1x2,boiler,64,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 -BK13/BK15/Smartline/GB1x2,boiler,64,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 -BK13/BK15/Smartline/GB1x2,boiler,64,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 -BK13/BK15/Smartline/GB1x2,boiler,64,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 -BK13/BK15/Smartline/GB1x2,boiler,64,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 -BK13/BK15/Smartline/GB1x2,boiler,64,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 -BK13/BK15/Smartline/GB1x2,boiler,64,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 -BK13/BK15/Smartline/GB1x2,boiler,64,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 -BK13/BK15/Smartline/GB1x2,boiler,64,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 -BK13/BK15/Smartline/GB1x2,boiler,64,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,5,0,1/10,232,1 -BK13/BK15/Smartline/GB1x2,boiler,64,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,5,0,1,233,1 -BK13/BK15/Smartline/GB1x2,boiler,64,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,5,0,1,234,1 -BK13/BK15/Smartline/GB1x2,boiler,64,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,5,0,1/10,235,1 -BK13/BK15/Smartline/GB1x2,boiler,64,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,5,0,1,236,1 -BK13/BK15/Smartline/GB1x2,boiler,64,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,5,0,1,237,1 -BK13/BK15/Smartline/GB1x2,boiler,64,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,5,0,1,238,1 -BK13/BK15/Smartline/GB1x2,boiler,64,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,5,0,1,239,1 -BK13/BK15/Smartline/GB1x2,boiler,64,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,5,0,1,240,1 -BK13/BK15/Smartline/GB1x2,boiler,64,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,5,0,1,241,1 -BK13/BK15/Smartline/GB1x2,boiler,64,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,5,0,1,242,1 -BK13/BK15/Smartline/GB1x2,boiler,64,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock,5,0,1/10,243,1 -BK13/BK15/Smartline/GB1x2,boiler,64,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,5,0,1,244,1 -BK13/BK15/Smartline/GB1x2,boiler,64,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,5,0,1,245,1 -BK13/BK15/Smartline/GB1x2,boiler,64,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,5,0,1,246,1 -BK13/BK15/Smartline/GB1x2,boiler,64,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,5,0,1,247,1 -BK13/BK15/Smartline/GB1x2,boiler,64,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,5,0,1,248,1 -BK13/BK15/Smartline/GB1x2,boiler,64,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,5,0,1,249,1 -BK13/BK15/Smartline/GB1x2,boiler,64,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,5,0,1,250,1 -BK13/BK15/Smartline/GB1x2,boiler,64,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,5,0,1,251,1 -BK13/BK15/Smartline/GB1x2,boiler,64,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,5,0,1,252,1 -BK13/BK15/Smartline/GB1x2,boiler,64,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,5,0,1,253,1 -BK13/BK15/Smartline/GB1x2,boiler,64,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 -BK13/BK15/Smartline/GB1x2,boiler,64,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 -BK13/BK15/Smartline/GB1x2,boiler,64,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 -BK13/BK15/Smartline/GB1x2,boiler,64,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 -BK13/BK15/Smartline/GB1x2,boiler,64,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 -BK13/BK15/Smartline/GB1x2,boiler,64,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 -BK13/BK15/Smartline/GB1x2,boiler,64,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 -BK13/BK15/Smartline/GB1x2,boiler,64,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 -BK13/BK15/Smartline/GB1x2,boiler,64,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 -BK13/BK15/Smartline/GB1x2,boiler,64,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 -BK13/BK15/Smartline/GB1x2,boiler,64,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 -BK13/BK15/Smartline/GB1x2,boiler,64,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2 -BK13/BK15/Smartline/GB1x2,boiler,64,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2 -BK13/BK15/Smartline/GB1x2,boiler,64,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2 -BK13/BK15/Smartline/GB1x2,boiler,64,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2 -BK13/BK15/Smartline/GB1x2,boiler,64,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2 -BK13/BK15/Smartline/GB1x2,boiler,64,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28 -BK13/BK15/Smartline/GB1x2,boiler,64,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2 -BK13/BK15/Smartline/GB1x2,boiler,64,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1 -BK13/BK15/Smartline/GB1x2,boiler,64,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2 -BK13/BK15/Smartline/GB1x2,boiler,64,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1 -BK13/BK15/Smartline/GB1x2,boiler,64,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1 -BK13/BK15/Smartline/GB1x2,boiler,64,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6 -BK13/BK15/Smartline/GB1x2,boiler,64,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1 -BK13/BK15/Smartline/GB1x2,boiler,64,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1 -BK13/BK15/Smartline/GB1x2,boiler,64,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,90,2 -BK13/BK15/Smartline/GB1x2,boiler,64,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 -BK13/BK15/Smartline/GB1x2,boiler,64,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,254,2 -BK13/BK15/Smartline/GB1x2,boiler,64,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 -BK13/BK15/Smartline/GB1x2,boiler,64,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,256,2 -BK13/BK15/Smartline/GB1x2,boiler,64,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 -BK13/BK15/Smartline/GB1x2,boiler,64,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 -BK13/BK15/Smartline/GB1x2,boiler,64,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 -BK13/BK15/Smartline/GB1x2,boiler,64,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 -BK13/BK15/Smartline/GB1x2,boiler,64,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 -BK13/BK15/Smartline/GB1x2,boiler,64,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 -BK13/BK15/Smartline/GB1x2,boiler,64,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 -BK13/BK15/Smartline/GB1x2,boiler,64,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 -BK13/BK15/Smartline/GB1x2,boiler,64,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 -BK13/BK15/Smartline/GB1x2,boiler,64,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 -BK13/BK15/Smartline/GB1x2,boiler,64,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 -BK13/BK15/Smartline/GB1x2,boiler,64,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 -BK13/BK15/Smartline/GB1x2,boiler,64,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 -BK13/BK15/Smartline/GB1x2,boiler,64,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 -BK13/BK15/Smartline/GB1x2,boiler,64,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 -BK13/BK15/Smartline/GB1x2,boiler,64,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 -BK13/BK15/Smartline/GB1x2,boiler,64,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 -BK13/BK15/Smartline/GB1x2,boiler,64,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 -BK13/BK15/Smartline/GB1x2,boiler,64,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 -BK13/BK15/Smartline/GB1x2,boiler,64,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 -BK13/BK15/Smartline/GB1x2,boiler,64,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 -BK13/BK15/Smartline/GB1x2,boiler,64,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 -BK13/BK15/Smartline/GB1x2,boiler,64,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 -BK13/BK15/Smartline/GB1x2,boiler,64,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 -BK13/BK15/Smartline/GB1x2,boiler,64,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 -BK13/BK15/Smartline/GB1x2,boiler,64,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 -BK13/BK15/Smartline/GB1x2,boiler,64,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 -BK13/BK15/Smartline/GB1x2,boiler,64,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 -BK13/BK15/Smartline/GB1x2,boiler,64,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 -BK13/BK15/Smartline/GB1x2,boiler,64,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 -BK13/BK15/Smartline/GB1x2,boiler,64,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 -BK13/BK15/Smartline/GB1x2,boiler,64,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 -BK13/BK15/Smartline/GB1x2,boiler,64,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 -BK13/BK15/Smartline/GB1x2,boiler,64,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 -BK13/BK15/Smartline/GB1x2,boiler,64,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 -BK13/BK15/Smartline/GB1x2,boiler,64,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -BK13/BK15/Smartline/GB1x2,boiler,64,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 -BK13/BK15/Smartline/GB1x2,boiler,64,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 -BK13/BK15/Smartline/GB1x2,boiler,64,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 -BK13/BK15/Smartline/GB1x2,boiler,64,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 -BK13/BK15/Smartline/GB1x2,boiler,64,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,258,1 -BK13/BK15/Smartline/GB1x2,boiler,64,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 -BK13/BK15/Smartline/GB1x2,boiler,64,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2 -BK13/BK15/Smartline/GB1x2,boiler,64,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2 -GB125/GB135/MC10,boiler,72,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 -GB125/GB135/MC10,boiler,72,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 -GB125/GB135/MC10,boiler,72,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 -GB125/GB135/MC10,boiler,72,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 -GB125/GB135/MC10,boiler,72,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 -GB125/GB135/MC10,boiler,72,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 -GB125/GB135/MC10,boiler,72,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 -GB125/GB135/MC10,boiler,72,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 -GB125/GB135/MC10,boiler,72,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 -GB125/GB135/MC10,boiler,72,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 -GB125/GB135/MC10,boiler,72,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 -GB125/GB135/MC10,boiler,72,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 -GB125/GB135/MC10,boiler,72,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 -GB125/GB135/MC10,boiler,72,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,5,0,1/10,232,1 -GB125/GB135/MC10,boiler,72,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,5,0,1,233,1 -GB125/GB135/MC10,boiler,72,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,5,0,1,234,1 -GB125/GB135/MC10,boiler,72,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,5,0,1/10,235,1 -GB125/GB135/MC10,boiler,72,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,5,0,1,236,1 -GB125/GB135/MC10,boiler,72,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,5,0,1,237,1 -GB125/GB135/MC10,boiler,72,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,5,0,1,238,1 -GB125/GB135/MC10,boiler,72,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,5,0,1,239,1 -GB125/GB135/MC10,boiler,72,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,5,0,1,240,1 -GB125/GB135/MC10,boiler,72,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,5,0,1,241,1 -GB125/GB135/MC10,boiler,72,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,5,0,1,242,1 -GB125/GB135/MC10,boiler,72,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock,5,0,1/10,243,1 -GB125/GB135/MC10,boiler,72,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,5,0,1,244,1 -GB125/GB135/MC10,boiler,72,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,5,0,1,245,1 -GB125/GB135/MC10,boiler,72,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,5,0,1,246,1 -GB125/GB135/MC10,boiler,72,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,5,0,1,247,1 -GB125/GB135/MC10,boiler,72,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,5,0,1,248,1 -GB125/GB135/MC10,boiler,72,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,5,0,1,249,1 -GB125/GB135/MC10,boiler,72,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,5,0,1,250,1 -GB125/GB135/MC10,boiler,72,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,5,0,1,251,1 -GB125/GB135/MC10,boiler,72,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,5,0,1,252,1 -GB125/GB135/MC10,boiler,72,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,5,0,1,253,1 -GB125/GB135/MC10,boiler,72,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 -GB125/GB135/MC10,boiler,72,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 -GB125/GB135/MC10,boiler,72,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 -GB125/GB135/MC10,boiler,72,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 -GB125/GB135/MC10,boiler,72,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 -GB125/GB135/MC10,boiler,72,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 -GB125/GB135/MC10,boiler,72,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 -GB125/GB135/MC10,boiler,72,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 -GB125/GB135/MC10,boiler,72,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 -GB125/GB135/MC10,boiler,72,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 -GB125/GB135/MC10,boiler,72,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 -GB125/GB135/MC10,boiler,72,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2 -GB125/GB135/MC10,boiler,72,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2 -GB125/GB135/MC10,boiler,72,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2 -GB125/GB135/MC10,boiler,72,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2 -GB125/GB135/MC10,boiler,72,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2 -GB125/GB135/MC10,boiler,72,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28 -GB125/GB135/MC10,boiler,72,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2 -GB125/GB135/MC10,boiler,72,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1 -GB125/GB135/MC10,boiler,72,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2 -GB125/GB135/MC10,boiler,72,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1 -GB125/GB135/MC10,boiler,72,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1 -GB125/GB135/MC10,boiler,72,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6 -GB125/GB135/MC10,boiler,72,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1 -GB125/GB135/MC10,boiler,72,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1 -GB125/GB135/MC10,boiler,72,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,90,2 -GB125/GB135/MC10,boiler,72,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 -GB125/GB135/MC10,boiler,72,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,254,2 -GB125/GB135/MC10,boiler,72,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 -GB125/GB135/MC10,boiler,72,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,256,2 -GB125/GB135/MC10,boiler,72,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 -GB125/GB135/MC10,boiler,72,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 -GB125/GB135/MC10,boiler,72,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 -GB125/GB135/MC10,boiler,72,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 -GB125/GB135/MC10,boiler,72,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 -GB125/GB135/MC10,boiler,72,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 -GB125/GB135/MC10,boiler,72,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 -GB125/GB135/MC10,boiler,72,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 -GB125/GB135/MC10,boiler,72,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 -GB125/GB135/MC10,boiler,72,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 -GB125/GB135/MC10,boiler,72,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 -GB125/GB135/MC10,boiler,72,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 -GB125/GB135/MC10,boiler,72,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 -GB125/GB135/MC10,boiler,72,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 -GB125/GB135/MC10,boiler,72,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 -GB125/GB135/MC10,boiler,72,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 -GB125/GB135/MC10,boiler,72,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 -GB125/GB135/MC10,boiler,72,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 -GB125/GB135/MC10,boiler,72,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 -GB125/GB135/MC10,boiler,72,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 -GB125/GB135/MC10,boiler,72,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 -GB125/GB135/MC10,boiler,72,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 -GB125/GB135/MC10,boiler,72,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 -GB125/GB135/MC10,boiler,72,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 -GB125/GB135/MC10,boiler,72,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 -GB125/GB135/MC10,boiler,72,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 -GB125/GB135/MC10,boiler,72,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 -GB125/GB135/MC10,boiler,72,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 -GB125/GB135/MC10,boiler,72,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 -GB125/GB135/MC10,boiler,72,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 -GB125/GB135/MC10,boiler,72,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 -GB125/GB135/MC10,boiler,72,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 -GB125/GB135/MC10,boiler,72,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 -GB125/GB135/MC10,boiler,72,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 -GB125/GB135/MC10,boiler,72,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 -GB125/GB135/MC10,boiler,72,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -GB125/GB135/MC10,boiler,72,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 -GB125/GB135/MC10,boiler,72,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 -GB125/GB135/MC10,boiler,72,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 -GB125/GB135/MC10,boiler,72,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 -GB125/GB135/MC10,boiler,72,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,258,1 -GB125/GB135/MC10,boiler,72,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 -GB125/GB135/MC10,boiler,72,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2 -GB125/GB135/MC10,boiler,72,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2 +BK13/BK15, Smartline, GB1*2,boiler,64,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 +BK13/BK15, Smartline, GB1*2,boiler,64,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 +BK13/BK15, Smartline, GB1*2,boiler,64,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 +BK13/BK15, Smartline, GB1*2,boiler,64,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 +BK13/BK15, Smartline, GB1*2,boiler,64,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 +BK13/BK15, Smartline, GB1*2,boiler,64,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 +BK13/BK15, Smartline, GB1*2,boiler,64,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 +BK13/BK15, Smartline, GB1*2,boiler,64,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 +BK13/BK15, Smartline, GB1*2,boiler,64,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 +BK13/BK15, Smartline, GB1*2,boiler,64,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 +BK13/BK15, Smartline, GB1*2,boiler,64,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 +BK13/BK15, Smartline, GB1*2,boiler,64,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 +BK13/BK15, Smartline, GB1*2,boiler,64,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 +BK13/BK15, Smartline, GB1*2,boiler,64,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,5,0,1/10,232,1 +BK13/BK15, Smartline, GB1*2,boiler,64,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,5,0,1,233,1 +BK13/BK15, Smartline, GB1*2,boiler,64,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,5,0,1,234,1 +BK13/BK15, Smartline, GB1*2,boiler,64,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,5,0,1/10,235,1 +BK13/BK15, Smartline, GB1*2,boiler,64,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,5,0,1,236,1 +BK13/BK15, Smartline, GB1*2,boiler,64,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,5,0,1,237,1 +BK13/BK15, Smartline, GB1*2,boiler,64,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,5,0,1,238,1 +BK13/BK15, Smartline, GB1*2,boiler,64,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,5,0,1,239,1 +BK13/BK15, Smartline, GB1*2,boiler,64,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,5,0,1,240,1 +BK13/BK15, Smartline, GB1*2,boiler,64,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,5,0,1,241,1 +BK13/BK15, Smartline, GB1*2,boiler,64,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,5,0,1,242,1 +BK13/BK15, Smartline, GB1*2,boiler,64,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock,5,0,1/10,243,1 +BK13/BK15, Smartline, GB1*2,boiler,64,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,5,0,1,244,1 +BK13/BK15, Smartline, GB1*2,boiler,64,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,5,0,1,245,1 +BK13/BK15, Smartline, GB1*2,boiler,64,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,5,0,1,246,1 +BK13/BK15, Smartline, GB1*2,boiler,64,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,5,0,1,247,1 +BK13/BK15, Smartline, GB1*2,boiler,64,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,5,0,1,248,1 +BK13/BK15, Smartline, GB1*2,boiler,64,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,5,0,1,249,1 +BK13/BK15, Smartline, GB1*2,boiler,64,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,5,0,1,250,1 +BK13/BK15, Smartline, GB1*2,boiler,64,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,5,0,1,251,1 +BK13/BK15, Smartline, GB1*2,boiler,64,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,5,0,1,252,1 +BK13/BK15, Smartline, GB1*2,boiler,64,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,5,0,1,253,1 +BK13/BK15, Smartline, GB1*2,boiler,64,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 +BK13/BK15, Smartline, GB1*2,boiler,64,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 +BK13/BK15, Smartline, GB1*2,boiler,64,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 +BK13/BK15, Smartline, GB1*2,boiler,64,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 +BK13/BK15, Smartline, GB1*2,boiler,64,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 +BK13/BK15, Smartline, GB1*2,boiler,64,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 +BK13/BK15, Smartline, GB1*2,boiler,64,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 +BK13/BK15, Smartline, GB1*2,boiler,64,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 +BK13/BK15, Smartline, GB1*2,boiler,64,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1 +BK13/BK15, Smartline, GB1*2,boiler,64,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 +BK13/BK15, Smartline, GB1*2,boiler,64,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 +BK13/BK15, Smartline, GB1*2,boiler,64,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 +BK13/BK15, Smartline, GB1*2,boiler,64,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2 +BK13/BK15, Smartline, GB1*2,boiler,64,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2 +BK13/BK15, Smartline, GB1*2,boiler,64,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2 +BK13/BK15, Smartline, GB1*2,boiler,64,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2 +BK13/BK15, Smartline, GB1*2,boiler,64,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2 +BK13/BK15, Smartline, GB1*2,boiler,64,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28 +BK13/BK15, Smartline, GB1*2,boiler,64,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2 +BK13/BK15, Smartline, GB1*2,boiler,64,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1 +BK13/BK15, Smartline, GB1*2,boiler,64,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2 +BK13/BK15, Smartline, GB1*2,boiler,64,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1 +BK13/BK15, Smartline, GB1*2,boiler,64,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1 +BK13/BK15, Smartline, GB1*2,boiler,64,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6 +BK13/BK15, Smartline, GB1*2,boiler,64,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1 +BK13/BK15, Smartline, GB1*2,boiler,64,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1 +BK13/BK15, Smartline, GB1*2,boiler,64,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,90,2 +BK13/BK15, Smartline, GB1*2,boiler,64,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 +BK13/BK15, Smartline, GB1*2,boiler,64,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,254,2 +BK13/BK15, Smartline, GB1*2,boiler,64,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 +BK13/BK15, Smartline, GB1*2,boiler,64,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,256,2 +BK13/BK15, Smartline, GB1*2,boiler,64,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 +BK13/BK15, Smartline, GB1*2,boiler,64,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 +BK13/BK15, Smartline, GB1*2,boiler,64,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 +BK13/BK15, Smartline, GB1*2,boiler,64,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 +BK13/BK15, Smartline, GB1*2,boiler,64,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 +BK13/BK15, Smartline, GB1*2,boiler,64,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 +BK13/BK15, Smartline, GB1*2,boiler,64,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 +BK13/BK15, Smartline, GB1*2,boiler,64,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 +BK13/BK15, Smartline, GB1*2,boiler,64,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 +BK13/BK15, Smartline, GB1*2,boiler,64,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 +BK13/BK15, Smartline, GB1*2,boiler,64,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 +BK13/BK15, Smartline, GB1*2,boiler,64,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 +BK13/BK15, Smartline, GB1*2,boiler,64,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 +BK13/BK15, Smartline, GB1*2,boiler,64,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 +BK13/BK15, Smartline, GB1*2,boiler,64,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 +BK13/BK15, Smartline, GB1*2,boiler,64,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 +BK13/BK15, Smartline, GB1*2,boiler,64,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 +BK13/BK15, Smartline, GB1*2,boiler,64,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 +BK13/BK15, Smartline, GB1*2,boiler,64,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 +BK13/BK15, Smartline, GB1*2,boiler,64,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 +BK13/BK15, Smartline, GB1*2,boiler,64,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 +BK13/BK15, Smartline, GB1*2,boiler,64,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 +BK13/BK15, Smartline, GB1*2,boiler,64,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 +BK13/BK15, Smartline, GB1*2,boiler,64,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 +BK13/BK15, Smartline, GB1*2,boiler,64,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 +BK13/BK15, Smartline, GB1*2,boiler,64,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 +BK13/BK15, Smartline, GB1*2,boiler,64,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 +BK13/BK15, Smartline, GB1*2,boiler,64,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 +BK13/BK15, Smartline, GB1*2,boiler,64,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 +BK13/BK15, Smartline, GB1*2,boiler,64,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 +BK13/BK15, Smartline, GB1*2,boiler,64,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 +BK13/BK15, Smartline, GB1*2,boiler,64,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 +BK13/BK15, Smartline, GB1*2,boiler,64,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 +BK13/BK15, Smartline, GB1*2,boiler,64,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 +BK13/BK15, Smartline, GB1*2,boiler,64,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 +BK13/BK15, Smartline, GB1*2,boiler,64,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 +BK13/BK15, Smartline, GB1*2,boiler,64,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +BK13/BK15, Smartline, GB1*2,boiler,64,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +BK13/BK15, Smartline, GB1*2,boiler,64,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +BK13/BK15, Smartline, GB1*2,boiler,64,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 +BK13/BK15, Smartline, GB1*2,boiler,64,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,258,1 +BK13/BK15, Smartline, GB1*2,boiler,64,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 +BK13/BK15, Smartline, GB1*2,boiler,64,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2 +BK13/BK15, Smartline, GB1*2,boiler,64,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2 +Logano GB1*5, Logamatic MC10,boiler,72,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 +Logano GB1*5, Logamatic MC10,boiler,72,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 +Logano GB1*5, Logamatic MC10,boiler,72,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 +Logano GB1*5, Logamatic MC10,boiler,72,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 +Logano GB1*5, Logamatic MC10,boiler,72,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 +Logano GB1*5, Logamatic MC10,boiler,72,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 +Logano GB1*5, Logamatic MC10,boiler,72,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 +Logano GB1*5, Logamatic MC10,boiler,72,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 +Logano GB1*5, Logamatic MC10,boiler,72,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 +Logano GB1*5, Logamatic MC10,boiler,72,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 +Logano GB1*5, Logamatic MC10,boiler,72,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 +Logano GB1*5, Logamatic MC10,boiler,72,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 +Logano GB1*5, Logamatic MC10,boiler,72,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 +Logano GB1*5, Logamatic MC10,boiler,72,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,5,0,1/10,232,1 +Logano GB1*5, Logamatic MC10,boiler,72,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,5,0,1,233,1 +Logano GB1*5, Logamatic MC10,boiler,72,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,5,0,1,234,1 +Logano GB1*5, Logamatic MC10,boiler,72,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,5,0,1/10,235,1 +Logano GB1*5, Logamatic MC10,boiler,72,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,5,0,1,236,1 +Logano GB1*5, Logamatic MC10,boiler,72,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,5,0,1,237,1 +Logano GB1*5, Logamatic MC10,boiler,72,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,5,0,1,238,1 +Logano GB1*5, Logamatic MC10,boiler,72,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,5,0,1,239,1 +Logano GB1*5, Logamatic MC10,boiler,72,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,5,0,1,240,1 +Logano GB1*5, Logamatic MC10,boiler,72,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,5,0,1,241,1 +Logano GB1*5, Logamatic MC10,boiler,72,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,5,0,1,242,1 +Logano GB1*5, Logamatic MC10,boiler,72,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock,5,0,1/10,243,1 +Logano GB1*5, Logamatic MC10,boiler,72,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,5,0,1,244,1 +Logano GB1*5, Logamatic MC10,boiler,72,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,5,0,1,245,1 +Logano GB1*5, Logamatic MC10,boiler,72,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,5,0,1,246,1 +Logano GB1*5, Logamatic MC10,boiler,72,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,5,0,1,247,1 +Logano GB1*5, Logamatic MC10,boiler,72,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,5,0,1,248,1 +Logano GB1*5, Logamatic MC10,boiler,72,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,5,0,1,249,1 +Logano GB1*5, Logamatic MC10,boiler,72,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,5,0,1,250,1 +Logano GB1*5, Logamatic MC10,boiler,72,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,5,0,1,251,1 +Logano GB1*5, Logamatic MC10,boiler,72,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,5,0,1,252,1 +Logano GB1*5, Logamatic MC10,boiler,72,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,5,0,1,253,1 +Logano GB1*5, Logamatic MC10,boiler,72,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 +Logano GB1*5, Logamatic MC10,boiler,72,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 +Logano GB1*5, Logamatic MC10,boiler,72,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 +Logano GB1*5, Logamatic MC10,boiler,72,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 +Logano GB1*5, Logamatic MC10,boiler,72,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 +Logano GB1*5, Logamatic MC10,boiler,72,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 +Logano GB1*5, Logamatic MC10,boiler,72,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 +Logano GB1*5, Logamatic MC10,boiler,72,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 +Logano GB1*5, Logamatic MC10,boiler,72,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1 +Logano GB1*5, Logamatic MC10,boiler,72,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 +Logano GB1*5, Logamatic MC10,boiler,72,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 +Logano GB1*5, Logamatic MC10,boiler,72,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 +Logano GB1*5, Logamatic MC10,boiler,72,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2 +Logano GB1*5, Logamatic MC10,boiler,72,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2 +Logano GB1*5, Logamatic MC10,boiler,72,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2 +Logano GB1*5, Logamatic MC10,boiler,72,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2 +Logano GB1*5, Logamatic MC10,boiler,72,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2 +Logano GB1*5, Logamatic MC10,boiler,72,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28 +Logano GB1*5, Logamatic MC10,boiler,72,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2 +Logano GB1*5, Logamatic MC10,boiler,72,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1 +Logano GB1*5, Logamatic MC10,boiler,72,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2 +Logano GB1*5, Logamatic MC10,boiler,72,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1 +Logano GB1*5, Logamatic MC10,boiler,72,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1 +Logano GB1*5, Logamatic MC10,boiler,72,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6 +Logano GB1*5, Logamatic MC10,boiler,72,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1 +Logano GB1*5, Logamatic MC10,boiler,72,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1 +Logano GB1*5, Logamatic MC10,boiler,72,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,90,2 +Logano GB1*5, Logamatic MC10,boiler,72,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 +Logano GB1*5, Logamatic MC10,boiler,72,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,254,2 +Logano GB1*5, Logamatic MC10,boiler,72,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 +Logano GB1*5, Logamatic MC10,boiler,72,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,256,2 +Logano GB1*5, Logamatic MC10,boiler,72,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 +Logano GB1*5, Logamatic MC10,boiler,72,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 +Logano GB1*5, Logamatic MC10,boiler,72,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 +Logano GB1*5, Logamatic MC10,boiler,72,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 +Logano GB1*5, Logamatic MC10,boiler,72,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 +Logano GB1*5, Logamatic MC10,boiler,72,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 +Logano GB1*5, Logamatic MC10,boiler,72,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 +Logano GB1*5, Logamatic MC10,boiler,72,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 +Logano GB1*5, Logamatic MC10,boiler,72,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 +Logano GB1*5, Logamatic MC10,boiler,72,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 +Logano GB1*5, Logamatic MC10,boiler,72,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 +Logano GB1*5, Logamatic MC10,boiler,72,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 +Logano GB1*5, Logamatic MC10,boiler,72,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 +Logano GB1*5, Logamatic MC10,boiler,72,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 +Logano GB1*5, Logamatic MC10,boiler,72,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 +Logano GB1*5, Logamatic MC10,boiler,72,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 +Logano GB1*5, Logamatic MC10,boiler,72,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 +Logano GB1*5, Logamatic MC10,boiler,72,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 +Logano GB1*5, Logamatic MC10,boiler,72,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 +Logano GB1*5, Logamatic MC10,boiler,72,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 +Logano GB1*5, Logamatic MC10,boiler,72,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 +Logano GB1*5, Logamatic MC10,boiler,72,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 +Logano GB1*5, Logamatic MC10,boiler,72,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 +Logano GB1*5, Logamatic MC10,boiler,72,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 +Logano GB1*5, Logamatic MC10,boiler,72,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 +Logano GB1*5, Logamatic MC10,boiler,72,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 +Logano GB1*5, Logamatic MC10,boiler,72,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 +Logano GB1*5, Logamatic MC10,boiler,72,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 +Logano GB1*5, Logamatic MC10,boiler,72,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 +Logano GB1*5, Logamatic MC10,boiler,72,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 +Logano GB1*5, Logamatic MC10,boiler,72,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 +Logano GB1*5, Logamatic MC10,boiler,72,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 +Logano GB1*5, Logamatic MC10,boiler,72,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 +Logano GB1*5, Logamatic MC10,boiler,72,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 +Logano GB1*5, Logamatic MC10,boiler,72,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 +Logano GB1*5, Logamatic MC10,boiler,72,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 +Logano GB1*5, Logamatic MC10,boiler,72,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +Logano GB1*5, Logamatic MC10,boiler,72,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +Logano GB1*5, Logamatic MC10,boiler,72,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +Logano GB1*5, Logamatic MC10,boiler,72,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 +Logano GB1*5, Logamatic MC10,boiler,72,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,258,1 +Logano GB1*5, Logamatic MC10,boiler,72,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 +Logano GB1*5, Logamatic MC10,boiler,72,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2 +Logano GB1*5, Logamatic MC10,boiler,72,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2 Cascade CM10,boiler,81,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 Cascade CM10,boiler,81,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 Cascade CM10,boiler,81,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 @@ -572,6 +577,7 @@ Cascade CM10,boiler,81,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true, Cascade CM10,boiler,81,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 Cascade CM10,boiler,81,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 Cascade CM10,boiler,81,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 +Cascade CM10,boiler,81,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1 Cascade CM10,boiler,81,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 Cascade CM10,boiler,81,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 Cascade CM10,boiler,81,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 @@ -681,6 +687,7 @@ Logamax Plus GB022,boiler,84,pumpmodmin,boiler pump min power,uint8 (>=0<=100),% Logamax Plus GB022,boiler,84,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 Logamax Plus GB022,boiler,84,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 Logamax Plus GB022,boiler,84,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 +Logamax Plus GB022,boiler,84,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1 Logamax Plus GB022,boiler,84,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 Logamax Plus GB022,boiler,84,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 Logamax Plus GB022,boiler,84,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 @@ -747,224 +754,226 @@ Logamax Plus GB022,boiler,84,nompower,nominal Power,uint8 (>=0<=254),kW,true,num Logamax Plus GB022,boiler,84,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 Logamax Plus GB022,boiler,84,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2 Logamax Plus GB022,boiler,84,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,5,0,1/10,232,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,5,0,1,233,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,5,0,1,234,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,5,0,1/10,235,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,5,0,1,236,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,5,0,1,237,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,5,0,1,238,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,5,0,1,239,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,5,0,1,240,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,5,0,1,241,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,5,0,1,242,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock,5,0,1/10,243,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,5,0,1,244,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,5,0,1,245,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,5,0,1,246,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,5,0,1,247,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,5,0,1,248,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,5,0,1,249,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,5,0,1,250,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,5,0,1,251,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,5,0,1,252,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,5,0,1,253,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,90,2 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,254,2 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,256,2 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,258,1 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2 -Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2 -Topline/GB162,boiler,115,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 -Topline/GB162,boiler,115,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 -Topline/GB162,boiler,115,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 -Topline/GB162,boiler,115,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 -Topline/GB162,boiler,115,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 -Topline/GB162,boiler,115,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 -Topline/GB162,boiler,115,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 -Topline/GB162,boiler,115,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 -Topline/GB162,boiler,115,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 -Topline/GB162,boiler,115,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 -Topline/GB162,boiler,115,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 -Topline/GB162,boiler,115,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 -Topline/GB162,boiler,115,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 -Topline/GB162,boiler,115,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,5,0,1/10,232,1 -Topline/GB162,boiler,115,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,5,0,1,233,1 -Topline/GB162,boiler,115,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,5,0,1,234,1 -Topline/GB162,boiler,115,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,5,0,1/10,235,1 -Topline/GB162,boiler,115,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,5,0,1,236,1 -Topline/GB162,boiler,115,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,5,0,1,237,1 -Topline/GB162,boiler,115,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,5,0,1,238,1 -Topline/GB162,boiler,115,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,5,0,1,239,1 -Topline/GB162,boiler,115,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,5,0,1,240,1 -Topline/GB162,boiler,115,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,5,0,1,241,1 -Topline/GB162,boiler,115,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,5,0,1,242,1 -Topline/GB162,boiler,115,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock,5,0,1/10,243,1 -Topline/GB162,boiler,115,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,5,0,1,244,1 -Topline/GB162,boiler,115,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,5,0,1,245,1 -Topline/GB162,boiler,115,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,5,0,1,246,1 -Topline/GB162,boiler,115,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,5,0,1,247,1 -Topline/GB162,boiler,115,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,5,0,1,248,1 -Topline/GB162,boiler,115,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,5,0,1,249,1 -Topline/GB162,boiler,115,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,5,0,1,250,1 -Topline/GB162,boiler,115,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,5,0,1,251,1 -Topline/GB162,boiler,115,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,5,0,1,252,1 -Topline/GB162,boiler,115,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,5,0,1,253,1 -Topline/GB162,boiler,115,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 -Topline/GB162,boiler,115,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 -Topline/GB162,boiler,115,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 -Topline/GB162,boiler,115,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 -Topline/GB162,boiler,115,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 -Topline/GB162,boiler,115,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 -Topline/GB162,boiler,115,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 -Topline/GB162,boiler,115,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 -Topline/GB162,boiler,115,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 -Topline/GB162,boiler,115,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 -Topline/GB162,boiler,115,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 -Topline/GB162,boiler,115,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2 -Topline/GB162,boiler,115,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2 -Topline/GB162,boiler,115,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2 -Topline/GB162,boiler,115,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2 -Topline/GB162,boiler,115,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2 -Topline/GB162,boiler,115,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28 -Topline/GB162,boiler,115,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2 -Topline/GB162,boiler,115,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1 -Topline/GB162,boiler,115,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2 -Topline/GB162,boiler,115,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1 -Topline/GB162,boiler,115,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1 -Topline/GB162,boiler,115,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6 -Topline/GB162,boiler,115,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1 -Topline/GB162,boiler,115,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1 -Topline/GB162,boiler,115,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,90,2 -Topline/GB162,boiler,115,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 -Topline/GB162,boiler,115,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,254,2 -Topline/GB162,boiler,115,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 -Topline/GB162,boiler,115,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,256,2 -Topline/GB162,boiler,115,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 -Topline/GB162,boiler,115,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 -Topline/GB162,boiler,115,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 -Topline/GB162,boiler,115,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 -Topline/GB162,boiler,115,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 -Topline/GB162,boiler,115,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 -Topline/GB162,boiler,115,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 -Topline/GB162,boiler,115,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 -Topline/GB162,boiler,115,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 -Topline/GB162,boiler,115,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 -Topline/GB162,boiler,115,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 -Topline/GB162,boiler,115,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 -Topline/GB162,boiler,115,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 -Topline/GB162,boiler,115,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 -Topline/GB162,boiler,115,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 -Topline/GB162,boiler,115,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 -Topline/GB162,boiler,115,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 -Topline/GB162,boiler,115,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 -Topline/GB162,boiler,115,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 -Topline/GB162,boiler,115,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 -Topline/GB162,boiler,115,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 -Topline/GB162,boiler,115,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 -Topline/GB162,boiler,115,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 -Topline/GB162,boiler,115,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 -Topline/GB162,boiler,115,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 -Topline/GB162,boiler,115,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 -Topline/GB162,boiler,115,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 -Topline/GB162,boiler,115,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 -Topline/GB162,boiler,115,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 -Topline/GB162,boiler,115,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 -Topline/GB162,boiler,115,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 -Topline/GB162,boiler,115,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 -Topline/GB162,boiler,115,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 -Topline/GB162,boiler,115,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 -Topline/GB162,boiler,115,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 -Topline/GB162,boiler,115,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -Topline/GB162,boiler,115,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 -Topline/GB162,boiler,115,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 -Topline/GB162,boiler,115,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 -Topline/GB162,boiler,115,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 -Topline/GB162,boiler,115,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,258,1 -Topline/GB162,boiler,115,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 -Topline/GB162,boiler,115,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2 -Topline/GB162,boiler,115,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,5,0,1/10,232,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,5,0,1,233,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,5,0,1,234,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,5,0,1/10,235,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,5,0,1,236,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,5,0,1,237,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,5,0,1,238,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,5,0,1,239,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,5,0,1,240,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,5,0,1,241,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,5,0,1,242,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock,5,0,1/10,243,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,5,0,1,244,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,5,0,1,245,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,5,0,1,246,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,5,0,1,247,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,5,0,1,248,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,5,0,1,249,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,5,0,1,250,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,5,0,1,251,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,5,0,1,252,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,5,0,1,253,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,90,2 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,254,2 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,256,2 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,258,1 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2 +Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3,boiler,95,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2 +Topline, GB162,boiler,115,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 +Topline, GB162,boiler,115,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 +Topline, GB162,boiler,115,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 +Topline, GB162,boiler,115,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 +Topline, GB162,boiler,115,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 +Topline, GB162,boiler,115,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 +Topline, GB162,boiler,115,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 +Topline, GB162,boiler,115,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 +Topline, GB162,boiler,115,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 +Topline, GB162,boiler,115,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 +Topline, GB162,boiler,115,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 +Topline, GB162,boiler,115,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 +Topline, GB162,boiler,115,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 +Topline, GB162,boiler,115,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,5,0,1/10,232,1 +Topline, GB162,boiler,115,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,5,0,1,233,1 +Topline, GB162,boiler,115,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,5,0,1,234,1 +Topline, GB162,boiler,115,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,5,0,1/10,235,1 +Topline, GB162,boiler,115,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,5,0,1,236,1 +Topline, GB162,boiler,115,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,5,0,1,237,1 +Topline, GB162,boiler,115,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,5,0,1,238,1 +Topline, GB162,boiler,115,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,5,0,1,239,1 +Topline, GB162,boiler,115,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,5,0,1,240,1 +Topline, GB162,boiler,115,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,5,0,1,241,1 +Topline, GB162,boiler,115,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,5,0,1,242,1 +Topline, GB162,boiler,115,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock,5,0,1/10,243,1 +Topline, GB162,boiler,115,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,5,0,1,244,1 +Topline, GB162,boiler,115,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,5,0,1,245,1 +Topline, GB162,boiler,115,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,5,0,1,246,1 +Topline, GB162,boiler,115,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,5,0,1,247,1 +Topline, GB162,boiler,115,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,5,0,1,248,1 +Topline, GB162,boiler,115,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,5,0,1,249,1 +Topline, GB162,boiler,115,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,5,0,1,250,1 +Topline, GB162,boiler,115,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,5,0,1,251,1 +Topline, GB162,boiler,115,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,5,0,1,252,1 +Topline, GB162,boiler,115,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,5,0,1,253,1 +Topline, GB162,boiler,115,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 +Topline, GB162,boiler,115,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 +Topline, GB162,boiler,115,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 +Topline, GB162,boiler,115,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 +Topline, GB162,boiler,115,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 +Topline, GB162,boiler,115,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 +Topline, GB162,boiler,115,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 +Topline, GB162,boiler,115,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 +Topline, GB162,boiler,115,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1 +Topline, GB162,boiler,115,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 +Topline, GB162,boiler,115,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 +Topline, GB162,boiler,115,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 +Topline, GB162,boiler,115,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2 +Topline, GB162,boiler,115,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2 +Topline, GB162,boiler,115,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2 +Topline, GB162,boiler,115,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2 +Topline, GB162,boiler,115,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2 +Topline, GB162,boiler,115,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28 +Topline, GB162,boiler,115,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2 +Topline, GB162,boiler,115,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1 +Topline, GB162,boiler,115,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2 +Topline, GB162,boiler,115,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1 +Topline, GB162,boiler,115,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1 +Topline, GB162,boiler,115,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6 +Topline, GB162,boiler,115,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1 +Topline, GB162,boiler,115,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1 +Topline, GB162,boiler,115,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,90,2 +Topline, GB162,boiler,115,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 +Topline, GB162,boiler,115,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,254,2 +Topline, GB162,boiler,115,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 +Topline, GB162,boiler,115,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,256,2 +Topline, GB162,boiler,115,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 +Topline, GB162,boiler,115,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 +Topline, GB162,boiler,115,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 +Topline, GB162,boiler,115,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 +Topline, GB162,boiler,115,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 +Topline, GB162,boiler,115,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 +Topline, GB162,boiler,115,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 +Topline, GB162,boiler,115,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 +Topline, GB162,boiler,115,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 +Topline, GB162,boiler,115,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 +Topline, GB162,boiler,115,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 +Topline, GB162,boiler,115,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 +Topline, GB162,boiler,115,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 +Topline, GB162,boiler,115,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 +Topline, GB162,boiler,115,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 +Topline, GB162,boiler,115,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 +Topline, GB162,boiler,115,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 +Topline, GB162,boiler,115,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 +Topline, GB162,boiler,115,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 +Topline, GB162,boiler,115,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 +Topline, GB162,boiler,115,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 +Topline, GB162,boiler,115,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 +Topline, GB162,boiler,115,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 +Topline, GB162,boiler,115,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 +Topline, GB162,boiler,115,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 +Topline, GB162,boiler,115,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 +Topline, GB162,boiler,115,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 +Topline, GB162,boiler,115,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 +Topline, GB162,boiler,115,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 +Topline, GB162,boiler,115,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 +Topline, GB162,boiler,115,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 +Topline, GB162,boiler,115,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 +Topline, GB162,boiler,115,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 +Topline, GB162,boiler,115,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 +Topline, GB162,boiler,115,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 +Topline, GB162,boiler,115,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 +Topline, GB162,boiler,115,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +Topline, GB162,boiler,115,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +Topline, GB162,boiler,115,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +Topline, GB162,boiler,115,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 +Topline, GB162,boiler,115,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,258,1 +Topline, GB162,boiler,115,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 +Topline, GB162,boiler,115,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2 +Topline, GB162,boiler,115,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2 Cascade MCM10,boiler,121,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 Cascade MCM10,boiler,121,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 Cascade MCM10,boiler,121,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 @@ -1008,6 +1017,7 @@ Cascade MCM10,boiler,121,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,tru Cascade MCM10,boiler,121,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 Cascade MCM10,boiler,121,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 Cascade MCM10,boiler,121,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 +Cascade MCM10,boiler,121,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1 Cascade MCM10,boiler,121,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 Cascade MCM10,boiler,121,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 Cascade MCM10,boiler,121,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 @@ -1117,6 +1127,7 @@ Proline,boiler,122,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,numb Proline,boiler,122,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 Proline,boiler,122,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 Proline,boiler,122,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 +Proline,boiler,122,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1 Proline,boiler,122,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 Proline,boiler,122,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 Proline,boiler,122,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 @@ -1183,115 +1194,116 @@ Proline,boiler,122,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler Proline,boiler,122,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 Proline,boiler,122,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2 Proline,boiler,122,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,5,0,1/10,232,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,5,0,1,233,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,5,0,1,234,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,5,0,1/10,235,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,5,0,1,236,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,5,0,1,237,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,5,0,1,238,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,5,0,1,239,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,5,0,1,240,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,5,0,1,241,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,5,0,1,242,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock,5,0,1/10,243,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,5,0,1,244,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,5,0,1,245,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,5,0,1,246,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,5,0,1,247,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,5,0,1,248,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,5,0,1,249,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,5,0,1,250,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,5,0,1,251,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,5,0,1,252,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,5,0,1,253,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,90,2 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,254,2 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,256,2 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,258,1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,5,0,1/10,232,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,5,0,1,233,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,5,0,1,234,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,5,0,1/10,235,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,5,0,1,236,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,5,0,1,237,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,5,0,1,238,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,5,0,1,239,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,5,0,1,240,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,5,0,1,241,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,5,0,1,242,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock,5,0,1/10,243,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,5,0,1,244,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,5,0,1,245,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,5,0,1,246,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,5,0,1,247,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,5,0,1,248,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,5,0,1,249,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,5,0,1,250,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,5,0,1,251,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,5,0,1,252,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,5,0,1,253,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,90,2 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,254,2 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,256,2 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,258,1 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2 +GB*72, Trendline, Cerapur, Greenstar Si,boiler,123,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2 GB212,boiler,131,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 GB212,boiler,131,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 GB212,boiler,131,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 @@ -1335,6 +1347,7 @@ GB212,boiler,131,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number GB212,boiler,131,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 GB212,boiler,131,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 GB212,boiler,131,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 +GB212,boiler,131,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1 GB212,boiler,131,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 GB212,boiler,131,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 GB212,boiler,131,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 @@ -1444,6 +1457,7 @@ GC7000F,boiler,132,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,numb GC7000F,boiler,132,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 GC7000F,boiler,132,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 GC7000F,boiler,132,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 +GC7000F,boiler,132,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1 GC7000F,boiler,132,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 GC7000F,boiler,132,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 GC7000F,boiler,132,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 @@ -1510,115 +1524,116 @@ GC7000F,boiler,132,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler GC7000F,boiler,132,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 GC7000F,boiler,132,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2 GC7000F,boiler,132,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2 -Logano GB125/KB195i/Logamatic MC110,boiler,133,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,5,0,1/10,232,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,5,0,1,233,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,5,0,1,234,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,5,0,1/10,235,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,5,0,1,236,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,5,0,1,237,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,5,0,1,238,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,5,0,1,239,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,5,0,1,240,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,5,0,1,241,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,5,0,1,242,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock,5,0,1/10,243,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,5,0,1,244,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,5,0,1,245,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,5,0,1,246,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,5,0,1,247,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,5,0,1,248,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,5,0,1,249,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,5,0,1,250,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,5,0,1,251,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,5,0,1,252,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,5,0,1,253,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 -Logano GB125/KB195i/Logamatic MC110,boiler,133,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2 -Logano GB125/KB195i/Logamatic MC110,boiler,133,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2 -Logano GB125/KB195i/Logamatic MC110,boiler,133,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2 -Logano GB125/KB195i/Logamatic MC110,boiler,133,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2 -Logano GB125/KB195i/Logamatic MC110,boiler,133,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2 -Logano GB125/KB195i/Logamatic MC110,boiler,133,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28 -Logano GB125/KB195i/Logamatic MC110,boiler,133,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2 -Logano GB125/KB195i/Logamatic MC110,boiler,133,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2 -Logano GB125/KB195i/Logamatic MC110,boiler,133,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6 -Logano GB125/KB195i/Logamatic MC110,boiler,133,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,90,2 -Logano GB125/KB195i/Logamatic MC110,boiler,133,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 -Logano GB125/KB195i/Logamatic MC110,boiler,133,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,254,2 -Logano GB125/KB195i/Logamatic MC110,boiler,133,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 -Logano GB125/KB195i/Logamatic MC110,boiler,133,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,256,2 -Logano GB125/KB195i/Logamatic MC110,boiler,133,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 -Logano GB125/KB195i/Logamatic MC110,boiler,133,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 -Logano GB125/KB195i/Logamatic MC110,boiler,133,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 -Logano GB125/KB195i/Logamatic MC110,boiler,133,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,258,1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 -Logano GB125/KB195i/Logamatic MC110,boiler,133,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2 -Logano GB125/KB195i/Logamatic MC110,boiler,133,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2 +Logano GB125/KB195i, Logamatic MC110,boiler,133,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,5,0,1/10,232,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,5,0,1,233,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,5,0,1,234,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,5,0,1/10,235,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,5,0,1,236,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,5,0,1,237,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,5,0,1,238,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,5,0,1,239,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,5,0,1,240,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,5,0,1,241,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,5,0,1,242,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock,5,0,1/10,243,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,5,0,1,244,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,5,0,1,245,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,5,0,1,246,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,5,0,1,247,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,5,0,1,248,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,5,0,1,249,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,5,0,1,250,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,5,0,1,251,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,5,0,1,252,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,5,0,1,253,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 +Logano GB125/KB195i, Logamatic MC110,boiler,133,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2 +Logano GB125/KB195i, Logamatic MC110,boiler,133,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2 +Logano GB125/KB195i, Logamatic MC110,boiler,133,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2 +Logano GB125/KB195i, Logamatic MC110,boiler,133,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2 +Logano GB125/KB195i, Logamatic MC110,boiler,133,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2 +Logano GB125/KB195i, Logamatic MC110,boiler,133,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28 +Logano GB125/KB195i, Logamatic MC110,boiler,133,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2 +Logano GB125/KB195i, Logamatic MC110,boiler,133,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2 +Logano GB125/KB195i, Logamatic MC110,boiler,133,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6 +Logano GB125/KB195i, Logamatic MC110,boiler,133,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,90,2 +Logano GB125/KB195i, Logamatic MC110,boiler,133,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 +Logano GB125/KB195i, Logamatic MC110,boiler,133,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,254,2 +Logano GB125/KB195i, Logamatic MC110,boiler,133,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 +Logano GB125/KB195i, Logamatic MC110,boiler,133,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,256,2 +Logano GB125/KB195i, Logamatic MC110,boiler,133,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 +Logano GB125/KB195i, Logamatic MC110,boiler,133,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +Logano GB125/KB195i, Logamatic MC110,boiler,133,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 +Logano GB125/KB195i, Logamatic MC110,boiler,133,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,258,1 +Logano GB125/KB195i, Logamatic MC110,boiler,133,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 +Logano GB125/KB195i, Logamatic MC110,boiler,133,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2 +Logano GB125/KB195i, Logamatic MC110,boiler,133,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2 Greenstar 30Ri Compact,boiler,154,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 Greenstar 30Ri Compact,boiler,154,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 Greenstar 30Ri Compact,boiler,154,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 @@ -1662,6 +1677,7 @@ Greenstar 30Ri Compact,boiler,154,pumpmodmin,boiler pump min power,uint8 (>=0<=1 Greenstar 30Ri Compact,boiler,154,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 Greenstar 30Ri Compact,boiler,154,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 Greenstar 30Ri Compact,boiler,154,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 +Greenstar 30Ri Compact,boiler,154,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1 Greenstar 30Ri Compact,boiler,154,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 Greenstar 30Ri Compact,boiler,154,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 Greenstar 30Ri Compact,boiler,154,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 @@ -1771,6 +1787,7 @@ Cerapur Aero,boiler,167,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true Cerapur Aero,boiler,167,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 Cerapur Aero,boiler,167,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 Cerapur Aero,boiler,167,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 +Cerapur Aero,boiler,167,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1 Cerapur Aero,boiler,167,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 Cerapur Aero,boiler,167,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 Cerapur Aero,boiler,167,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 @@ -1880,6 +1897,7 @@ Hybrid Heatpump,boiler,168,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,t Hybrid Heatpump,boiler,168,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 Hybrid Heatpump,boiler,168,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 Hybrid Heatpump,boiler,168,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 +Hybrid Heatpump,boiler,168,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1 Hybrid Heatpump,boiler,168,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 Hybrid Heatpump,boiler,168,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 Hybrid Heatpump,boiler,168,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 @@ -1989,6 +2007,7 @@ Logano GB212,boiler,170,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true Logano GB212,boiler,170,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 Logano GB212,boiler,170,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 Logano GB212,boiler,170,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 +Logano GB212,boiler,170,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1 Logano GB212,boiler,170,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 Logano GB212,boiler,170,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 Logano GB212,boiler,170,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 @@ -2055,209 +2074,211 @@ Logano GB212,boiler,170,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.b Logano GB212,boiler,170,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 Logano GB212,boiler,170,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2 Logano GB212,boiler,170,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrg,energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_energy,sensor.boiler_dhw_nrg,5,9,1/100,0,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_energy_heating,sensor.boiler_nrgheat,5,0,1/100,82,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgcool,energy cooling,uint24 (>=0<=167772),kWh,false,sensor.boiler_energy_cooling,sensor.boiler_nrgcool,5,0,1/100,264,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_total,sensor.boiler_metertotal,5,0,1/100,84,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_compressor,sensor.boiler_metercomp,5,0,1/100,86,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_e-heater,sensor.boiler_metereheat,5,0,1/100,88,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/100,90,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,metercool,meter cooling,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_cooling,sensor.boiler_metercool,5,0,1/100,266,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,meter,meter,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/100,2,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimetotal,heatpump total uptime,time (>=0<=279620),minutes,false,sensor.boiler_heatpump_total_uptime,sensor.boiler_uptimetotal,5,0,1/60,92,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimecontrol,total operating time heat,time (>=0<=279620),minutes,false,sensor.boiler_total_operating_time_heat,sensor.boiler_uptimecontrol,5,0,1/60,94,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimecompheating,operating time compressor heating,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_heating,sensor.boiler_uptimecompheating,5,0,1/60,96,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimecompcooling,operating time compressor cooling,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_cooling,sensor.boiler_uptimecompcooling,5,0,1/60,98,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimecomp,operating time compressor,time (>=0<=279620),minutes,false,sensor.boiler_dhw_operating_time_compressor,sensor.boiler_dhw_uptimecomp,5,9,1/60,4,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimecomppool,operating time compressor pool,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_pool,sensor.boiler_uptimecomppool,5,0,1/60,100,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,totalcompstarts,total compressor control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts,5,0,1,102,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingstarts,heating control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts,5,0,1,104,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,coolingstarts,cooling control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_cooling_control_starts,sensor.boiler_coolingstarts,5,0,1,106,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,starts2,control starts2,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_control_starts2,sensor.boiler_dhw_starts2,5,9,1,6,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,poolstarts,pool control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_pool_control_starts,sensor.boiler_poolstarts,5,0,1,108,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconstotal,total energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal,5,0,1,110,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscomptotal,total energy consumption compressor,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal,5,0,1,112,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscompheating,energy consumption compressor heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating,5,0,1,114,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscomp,energy consumption compressor,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_energy_consumption_compressor,sensor.boiler_dhw_nrgconscomp,5,9,1,8,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscompcooling,energy consumption compressor cooling,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling,5,0,1,116,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscomppool,energy consumption compressor pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool,5,0,1,118,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxelecheatnrgconstotal,total aux elec. heater energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal,5,0,1,120,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating,5,0,1,122,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxelecheatnrgcons,aux elec. heater energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_aux_elec._heater_energy_consumption,sensor.boiler_dhw_auxelecheatnrgcons,5,9,1,10,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxelecheatnrgconspool,aux elec. heater energy consumption pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool,5,0,1,124,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsupptotal,total energy supplied,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal,5,0,1,126,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsuppheating,total energy supplied heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating,5,0,1,128,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsupp,total energy warm supplied,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_total_energy_warm_supplied,sensor.boiler_dhw_nrgsupp,5,9,1,12,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsuppcooling,total energy supplied cooling,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling,5,0,1,130,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsupppool,total energy supplied pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool,5,0,1,132,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hppower,compressor power output,uint8 (>=0<=25),kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower,5,0,1/10,134,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpmaxpower,compressor max power,uint8 (>=0<=100),%,true,number.boiler_compressor_max_power,number.boiler_hpmaxpower,5,0,1,135,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpsetdiffpress,set differental pressure,uint8 (>=150<=750),mbar,true,number.boiler_set_differental_pressure,number.boiler_hpsetdiffpress,5,0,50,136,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpcompon,hp compressor,boolean, ,false,binary_sensor.boiler_hp_compressor,binary_sensor.boiler_hpcompon,5,0,1,137,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpactivity,compressor activity,enum [none\|heating\|cooling\|hot water\|pool\|unknown\|defrost], ,false,sensor.boiler_compressor_activity,sensor.boiler_hpactivity,5,0,1,138,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpbrinepumpspd,brine pump speed,uint8 (>=0<=100),%,false,sensor.boiler_brine_pump_speed,sensor.boiler_hpbrinepumpspd,5,0,1,139,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpswitchvalve,switch valve,boolean, ,false,binary_sensor.boiler_switch_valve,binary_sensor.boiler_hpswitchvalve,5,0,1,140,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpcompspd,compressor speed,uint8 (>=0<=100),%,false,sensor.boiler_compressor_speed,sensor.boiler_hpcompspd,5,0,1,141,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpcircspd,circulation pump speed,uint8 (>=0<=100),%,false,sensor.boiler_circulation_pump_speed,sensor.boiler_hpcircspd,5,0,1,142,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpbrinein,brine in/evaporator,int16 (>=-3199<=3199),C,false,sensor.boiler_brine_in/evaporator,sensor.boiler_hpbrinein,5,0,1/10,143,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpbrineout,brine out/condenser,int16 (>=-3199<=3199),C,false,sensor.boiler_brine_out/condenser,sensor.boiler_hpbrineout,5,0,1/10,144,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptc0,heat carrier return (TC0),int16 (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_return_(TC0),sensor.boiler_hptc0,5,0,1/10,145,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptc1,heat carrier forward (TC1),int16 (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_forward_(TC1),sensor.boiler_hptc1,5,0,1/10,146,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptc3,condenser temperature (TC3),int16 (>=-3199<=3199),C,false,sensor.boiler_condenser_temperature_(TC3),sensor.boiler_hptc3,5,0,1/10,147,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptr1,compressor temperature (TR1),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_temperature_(TR1),sensor.boiler_hptr1,5,0,1/10,148,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptr3,refrigerant temperature liquid side (condenser output) (TR3),int16 (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.boiler_hptr3,5,0,1/10,149,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptr4,evaporator inlet temperature (TR4),int16 (>=-3199<=3199),C,false,sensor.boiler_evaporator_inlet_temperature_(TR4),sensor.boiler_hptr4,5,0,1/10,150,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptr5,compressor inlet temperature (TR5),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_inlet_temperature_(TR5),sensor.boiler_hptr5,5,0,1/10,151,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptr6,compressor outlet temperature (TR6),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_outlet_temperature_(TR6),sensor.boiler_hptr6,5,0,1/10,152,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptr7,refrigerant temperature gas side (condenser input) (TR7),int16 (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7),sensor.boiler_hptr7,5,0,1/10,153,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptl2,air inlet temperature (TL2),int16 (>=-3199<=3199),C,false,sensor.boiler_air_inlet_temperature_(TL2),sensor.boiler_hptl2,5,0,1/10,154,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hppl1,low pressure side temperature (PL1),int16 (>=-3199<=3199),C,false,sensor.boiler_low_pressure_side_temperature_(PL1),sensor.boiler_hppl1,5,0,1/10,155,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpph1,high pressure side temperature (PH1),int16 (>=-3199<=3199),C,false,sensor.boiler_high_pressure_side_temperature_(PH1),sensor.boiler_hpph1,5,0,1/10,156,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpta4,drain pan temp (TA4),int16 (>=-3199<=3199),C,false,sensor.boiler_drain_pan_temp_(TA4),sensor.boiler_hpta4,5,0,1/10,157,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptw1,reservoir temp (TW1),int16 (>=-3199<=3199),C,false,sensor.boiler_reservoir_temp_(TW1),sensor.boiler_hptw1,5,0,1/10,158,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,poolsettemp,pool set temperature,uint8 (>=0<=127),C,true,number.boiler_pool_set_temperature,number.boiler_poolsettemp,5,0,1/2,159,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hp4way,4-way valve (VR4),enum [cooling & defrost\|heating & dhw], ,false,sensor.boiler_4-way_valve_(VR4),sensor.boiler_hp4way,5,0,1,160,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpin1,input 1 state,boolean, ,false,binary_sensor.boiler_input_1_state,binary_sensor.boiler_hpin1,5,0,1,161,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpin1opt,input 1 options,string, ,true,sensor.boiler_input_1_options,sensor.boiler_hpin1opt,5,0,1,162,8 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpin2,input 2 state,boolean, ,false,binary_sensor.boiler_input_2_state,binary_sensor.boiler_hpin2,5,0,1,170,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpin2opt,input 2 options,string, ,true,sensor.boiler_input_2_options,sensor.boiler_hpin2opt,5,0,1,171,8 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpin3,input 3 state,boolean, ,false,binary_sensor.boiler_input_3_state,binary_sensor.boiler_hpin3,5,0,1,179,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpin3opt,input 3 options,string, ,true,sensor.boiler_input_3_options,sensor.boiler_hpin3opt,5,0,1,180,8 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpin4,input 4 state,boolean, ,false,binary_sensor.boiler_input_4_state,binary_sensor.boiler_hpin4,5,0,1,188,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpin4opt,input 4 options,string, ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt,5,0,1,189,8 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maxheatcomp,heat limit compressor,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp,5,0,1,197,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maxheatheat,heat limit heating,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat,5,0,1,198,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maxheat,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_dhw_heat_limit,select.boiler_dhw_maxheat,5,9,1,14,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,mandefrost,manual defrost,boolean, ,true,switch.boiler_manual_defrost,switch.boiler_mandefrost,5,0,1,199,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pvcooling,cooling only with PV,boolean, ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling,5,0,1,200,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxheateronly,aux heater only,boolean, ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly,5,0,1,201,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxheateroff,disable aux heater,boolean, ,true,switch.boiler_disable_aux_heater,switch.boiler_auxheateroff,5,0,1,202,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxheaterstatus,aux heater status,uint8 (>=0<=100),%,false,sensor.boiler_aux_heater_status,sensor.boiler_auxheaterstatus,5,0,1,203,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxheaterdelay,aux heater on delay,uint16 (>=10<=1000),K*min,true,number.boiler_aux_heater_on_delay,number.boiler_auxheaterdelay,5,0,10,204,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxmaxlimit,aux heater max limit,uint8 (>=0<=10),K,true,number.boiler_aux_heater_max_limit,number.boiler_auxmaxlimit,5,0,1/10,205,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxlimitstart,aux heater limit start,uint8 (>=0<=10),K,true,number.boiler_aux_heater_limit_start,number.boiler_auxlimitstart,5,0,1/10,206,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxheatrmode,aux heater mode,enum [eco\|comfort], ,true,select.boiler_aux_heater_mode,select.boiler_auxheatrmode,5,0,1,207,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hphystheat,on/off hyst heat,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_heat,number.boiler_hphystheat,5,0,5,208,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hphystcool,on/off hyst cool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_cool,number.boiler_hphystcool,5,0,5,209,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hphystpool,on/off hyst pool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_pool,number.boiler_hphystpool,5,0,5,210,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,silentmode,silent mode,enum [off\|auto\|on], ,true,select.boiler_silent_mode,select.boiler_silentmode,5,0,1,211,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,silentfrom,silent mode from,uint8 (>=0<=3810),minutes,true,number.boiler_silent_mode_from,number.boiler_silentfrom,5,0,15,212,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,silentto,silent mode to,uint8 (>=0<=3810),minutes,true,number.boiler_silent_mode_to,number.boiler_silentto,5,0,15,213,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,mintempsilent,min outside temp for silent mode,int8 (>=-126<=126),C,true,number.boiler_min_outside_temp_for_silent_mode,number.boiler_mintempsilent,5,0,1,214,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,tempparmode,outside temp parallel mode,int8 (>=-126<=126),C,true,number.boiler_outside_temp_parallel_mode,number.boiler_tempparmode,5,0,1,215,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxheatmix,aux heater mixing valve,int8 (>=-100<=100),%,false,sensor.boiler_aux_heater_mixing_valve,sensor.boiler_auxheatmix,5,0,1,216,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,tempdiffheat,temp diff TC3/TC0 heat,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_heat,number.boiler_tempdiffheat,5,0,1/10,217,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,tempdiffcool,temp diff TC3/TC0 cool,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_cool,number.boiler_tempdiffcool,5,0,1/10,218,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,vpcooling,valve/pump cooling,boolean, ,true,switch.boiler_valve/pump_cooling,switch.boiler_vpcooling,5,0,1,219,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatcable,heating cable,boolean, ,true,switch.boiler_heating_cable,switch.boiler_heatcable,5,0,1,220,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,vc0valve,VC0 valve,boolean, ,true,switch.boiler_VC0_valve,switch.boiler_vc0valve,5,0,1,221,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,primepump,primary heatpump,boolean, ,true,switch.boiler_primary_heatpump,switch.boiler_primepump,5,0,1,222,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,primepumpmod,primary heatpump modulation,uint8 (>=0<=100),%,true,number.boiler_primary_heatpump_modulation,number.boiler_primepumpmod,5,0,1,223,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hp3way,3-way valve,boolean, ,true,switch.boiler_3-way_valve,switch.boiler_hp3way,5,0,1,224,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,elheatstep1,el. heater step 1,boolean, ,true,switch.boiler_el._heater_step_1,switch.boiler_elheatstep1,5,0,1,225,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,elheatstep2,el. heater step 2,boolean, ,true,switch.boiler_el._heater_step_2,switch.boiler_elheatstep2,5,0,1,226,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,elheatstep3,el. heater step 3,boolean, ,true,switch.boiler_el._heater_step_3,switch.boiler_elheatstep3,5,0,1,227,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpea0,condensate reservoir heating (EA0),boolean, ,false,binary_sensor.boiler_condensate_reservoir_heating_(EA0),binary_sensor.boiler_hpea0,5,0,1,228,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hppumpmode,primary heatpump mode,enum [auto\|continuous], ,true,select.boiler_primary_heatpump_mode,select.boiler_hppumpmode,5,0,1,229,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,fan,fan,uint8 (>=20<=100),%,true,number.boiler_fan,number.boiler_fan,5,0,1,230,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,shutdown,shutdown,cmd [off\|on], ,true,sensor.boiler_shutdown,sensor.boiler_shutdown,5,0,1,231,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpcurrpower,compressor current power,uint16 (>=0<=31999),W,false,sensor.boiler_compressor_current_power,sensor.boiler_hpcurrpower,5,0,1,268,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hppowerlimit,power limit,uint16 (>=0<=31999),W,true,number.boiler_power_limit,number.boiler_hppowerlimit,5,0,1,269,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pc0flow,Flow PC0,int16 (>=-31999<=31999),l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,5,0,1,270,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pc1flow,Flow PC1,int16 (>=-31999<=31999),l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,5,0,1,271,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,5,0,1,272,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pc1rate,PC1 rate,uint8 (>=0<=100),%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,5,0,1,273,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,alternatingop,alternating operation,boolean, ,true,switch.boiler_dhw_alternating_operation,switch.boiler_dhw_alternatingop,5,9,1,15,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,altopprioheat,prioritise heating during dhw,uint8 (>=20<=120),minutes,true,number.boiler_dhw_prioritise_heating_during_dhw,number.boiler_dhw_altopprioheat,5,9,1,16,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,altopprio,prioritise dhw during heating,uint8 (>=30<=120),minutes,true,number.boiler_dhw_prioritise_dhw_during_heating,number.boiler_dhw_altopprio,5,9,1,17,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,comfoff,comfort switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_comfort_switch_off,number.boiler_dhw_comfoff,5,9,1,18,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,ecooff,eco switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_eco_switch_off,number.boiler_dhw_ecooff,5,9,1,19,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,ecoplusoff,eco+ switch off,uint8 (>=48<=63),C,true,number.boiler_dhw_eco+_switch_off,number.boiler_dhw_ecoplusoff,5,9,1,20,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,comfdiff,comfort diff,uint8 (>=6<=12),K,true,number.boiler_dhw_comfort_diff,number.boiler_dhw_comfdiff,5,9,1,21,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,ecodiff,eco diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco_diff,number.boiler_dhw_ecodiff,5,9,1,22,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,ecoplusdiff,eco+ diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco+_diff,number.boiler_dhw_ecoplusdiff,5,9,1,23,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,comfstop,comfort stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_comfort_stop_temp,number.boiler_dhw_comfstop,5,9,1,24,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,ecostop,eco stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco_stop_temp,number.boiler_dhw_ecostop,5,9,1,25,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,ecoplusstop,eco+ stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco+_stop_temp,number.boiler_dhw_ecoplusstop,5,9,1,26,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpcircpump,circulation pump available during dhw,boolean, ,true,switch.boiler_dhw_circulation_pump_available_during_dhw,switch.boiler_dhw_hpcircpump,5,9,1,27,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,nrg,energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_energy,sensor.boiler_dhw_nrg,5,9,1/100,0,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_energy_heating,sensor.boiler_nrgheat,5,0,1/100,82,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,nrgcool,energy cooling,uint24 (>=0<=167772),kWh,false,sensor.boiler_energy_cooling,sensor.boiler_nrgcool,5,0,1/100,264,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_total,sensor.boiler_metertotal,5,0,1/100,84,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_compressor,sensor.boiler_metercomp,5,0,1/100,86,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_e-heater,sensor.boiler_metereheat,5,0,1/100,88,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/100,90,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,metercool,meter cooling,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_cooling,sensor.boiler_metercool,5,0,1/100,266,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,meter,meter,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/100,2,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,uptimetotal,heatpump total uptime,time (>=0<=279620),minutes,false,sensor.boiler_heatpump_total_uptime,sensor.boiler_uptimetotal,5,0,1/60,92,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,uptimecontrol,total operating time heat,time (>=0<=279620),minutes,false,sensor.boiler_total_operating_time_heat,sensor.boiler_uptimecontrol,5,0,1/60,94,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,uptimecompheating,operating time compressor heating,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_heating,sensor.boiler_uptimecompheating,5,0,1/60,96,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,uptimecompcooling,operating time compressor cooling,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_cooling,sensor.boiler_uptimecompcooling,5,0,1/60,98,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,uptimecomp,operating time compressor,time (>=0<=279620),minutes,false,sensor.boiler_dhw_operating_time_compressor,sensor.boiler_dhw_uptimecomp,5,9,1/60,4,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,uptimecomppool,operating time compressor pool,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_pool,sensor.boiler_uptimecomppool,5,0,1/60,100,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,totalcompstarts,total compressor control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts,5,0,1,102,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,heatingstarts,heating control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts,5,0,1,104,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,coolingstarts,cooling control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_cooling_control_starts,sensor.boiler_coolingstarts,5,0,1,106,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,starts2,control starts2,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_control_starts2,sensor.boiler_dhw_starts2,5,9,1,6,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,poolstarts,pool control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_pool_control_starts,sensor.boiler_poolstarts,5,0,1,108,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,nrgconstotal,total energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal,5,0,1,110,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,nrgconscomptotal,total energy consumption compressor,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal,5,0,1,112,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,nrgconscompheating,energy consumption compressor heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating,5,0,1,114,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,nrgconscomp,energy consumption compressor,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_energy_consumption_compressor,sensor.boiler_dhw_nrgconscomp,5,9,1,8,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,nrgconscompcooling,energy consumption compressor cooling,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling,5,0,1,116,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,nrgconscomppool,energy consumption compressor pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool,5,0,1,118,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,auxelecheatnrgconstotal,total aux elec. heater energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal,5,0,1,120,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating,5,0,1,122,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,auxelecheatnrgcons,aux elec. heater energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_aux_elec._heater_energy_consumption,sensor.boiler_dhw_auxelecheatnrgcons,5,9,1,10,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,auxelecheatnrgconspool,aux elec. heater energy consumption pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool,5,0,1,124,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,nrgsupptotal,total energy supplied,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal,5,0,1,126,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,nrgsuppheating,total energy supplied heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating,5,0,1,128,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,nrgsupp,total energy warm supplied,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_total_energy_warm_supplied,sensor.boiler_dhw_nrgsupp,5,9,1,12,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,nrgsuppcooling,total energy supplied cooling,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling,5,0,1,130,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,nrgsupppool,total energy supplied pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool,5,0,1,132,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hppower,compressor power output,uint8 (>=0<=25),kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower,5,0,1/10,134,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hpmaxpower,compressor max power,uint8 (>=0<=100),%,true,number.boiler_compressor_max_power,number.boiler_hpmaxpower,5,0,1,135,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,pvmaxcomp,pv compressor max power,uint8 (>=0<=25),kW,true,number.boiler_pv_compressor_max_power,number.boiler_pvmaxcomp,5,0,1/10,-1,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hpsetdiffpress,set differental pressure,uint8 (>=150<=750),mbar,true,number.boiler_set_differental_pressure,number.boiler_hpsetdiffpress,5,0,50,136,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hpcompon,hp compressor,boolean, ,false,binary_sensor.boiler_hp_compressor,binary_sensor.boiler_hpcompon,5,0,1,137,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hpactivity,compressor activity,enum [none\|heating\|cooling\|hot water\|pool\|unknown\|defrost], ,false,sensor.boiler_compressor_activity,sensor.boiler_hpactivity,5,0,1,138,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hpbrinepumpspd,brine pump speed,uint8 (>=0<=100),%,false,sensor.boiler_brine_pump_speed,sensor.boiler_hpbrinepumpspd,5,0,1,139,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hpswitchvalve,switch valve,boolean, ,false,binary_sensor.boiler_switch_valve,binary_sensor.boiler_hpswitchvalve,5,0,1,140,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hpcompspd,compressor speed,uint8 (>=0<=100),%,false,sensor.boiler_compressor_speed,sensor.boiler_hpcompspd,5,0,1,141,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hpcircspd,circulation pump speed,uint8 (>=0<=100),%,false,sensor.boiler_circulation_pump_speed,sensor.boiler_hpcircspd,5,0,1,142,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hpbrinein,brine in/evaporator,int16 (>=-3199<=3199),C,false,sensor.boiler_brine_in/evaporator,sensor.boiler_hpbrinein,5,0,1/10,143,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hpbrineout,brine out/condenser,int16 (>=-3199<=3199),C,false,sensor.boiler_brine_out/condenser,sensor.boiler_hpbrineout,5,0,1/10,144,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hptc0,heat carrier return (TC0),int16 (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_return_(TC0),sensor.boiler_hptc0,5,0,1/10,145,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hptc1,heat carrier forward (TC1),int16 (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_forward_(TC1),sensor.boiler_hptc1,5,0,1/10,146,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hptc3,condenser temperature (TC3),int16 (>=-3199<=3199),C,false,sensor.boiler_condenser_temperature_(TC3),sensor.boiler_hptc3,5,0,1/10,147,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hptr1,compressor temperature (TR1),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_temperature_(TR1),sensor.boiler_hptr1,5,0,1/10,148,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hptr3,refrigerant temperature liquid side (condenser output) (TR3),int16 (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.boiler_hptr3,5,0,1/10,149,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hptr4,evaporator inlet temperature (TR4),int16 (>=-3199<=3199),C,false,sensor.boiler_evaporator_inlet_temperature_(TR4),sensor.boiler_hptr4,5,0,1/10,150,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hptr5,compressor inlet temperature (TR5),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_inlet_temperature_(TR5),sensor.boiler_hptr5,5,0,1/10,151,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hptr6,compressor outlet temperature (TR6),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_outlet_temperature_(TR6),sensor.boiler_hptr6,5,0,1/10,152,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hptr7,refrigerant temperature gas side (condenser input) (TR7),int16 (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7),sensor.boiler_hptr7,5,0,1/10,153,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hptl2,air inlet temperature (TL2),int16 (>=-3199<=3199),C,false,sensor.boiler_air_inlet_temperature_(TL2),sensor.boiler_hptl2,5,0,1/10,154,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hppl1,low pressure side temperature (PL1),int16 (>=-3199<=3199),C,false,sensor.boiler_low_pressure_side_temperature_(PL1),sensor.boiler_hppl1,5,0,1/10,155,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hpph1,high pressure side temperature (PH1),int16 (>=-3199<=3199),C,false,sensor.boiler_high_pressure_side_temperature_(PH1),sensor.boiler_hpph1,5,0,1/10,156,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hpta4,drain pan temp (TA4),int16 (>=-3199<=3199),C,false,sensor.boiler_drain_pan_temp_(TA4),sensor.boiler_hpta4,5,0,1/10,157,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hptw1,reservoir temp (TW1),int16 (>=-3199<=3199),C,false,sensor.boiler_reservoir_temp_(TW1),sensor.boiler_hptw1,5,0,1/10,158,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,poolsettemp,pool set temperature,uint8 (>=0<=127),C,true,number.boiler_pool_set_temperature,number.boiler_poolsettemp,5,0,1/2,159,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hp4way,4-way valve (VR4),enum [cooling & defrost\|heating & dhw], ,false,sensor.boiler_4-way_valve_(VR4),sensor.boiler_hp4way,5,0,1,160,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hpin1,input 1 state,boolean, ,false,binary_sensor.boiler_input_1_state,binary_sensor.boiler_hpin1,5,0,1,161,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hpin1opt,input 1 options,string, ,true,sensor.boiler_input_1_options,sensor.boiler_hpin1opt,5,0,1,162,8 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hpin2,input 2 state,boolean, ,false,binary_sensor.boiler_input_2_state,binary_sensor.boiler_hpin2,5,0,1,170,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hpin2opt,input 2 options,string, ,true,sensor.boiler_input_2_options,sensor.boiler_hpin2opt,5,0,1,171,8 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hpin3,input 3 state,boolean, ,false,binary_sensor.boiler_input_3_state,binary_sensor.boiler_hpin3,5,0,1,179,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hpin3opt,input 3 options,string, ,true,sensor.boiler_input_3_options,sensor.boiler_hpin3opt,5,0,1,180,8 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hpin4,input 4 state,boolean, ,false,binary_sensor.boiler_input_4_state,binary_sensor.boiler_hpin4,5,0,1,188,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hpin4opt,input 4 options,string, ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt,5,0,1,189,8 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,maxheatcomp,heat limit compressor,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp,5,0,1,197,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,maxheatheat,heat limit heating,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat,5,0,1,198,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,maxheat,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_dhw_heat_limit,select.boiler_dhw_maxheat,5,9,1,14,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,mandefrost,manual defrost,boolean, ,true,switch.boiler_manual_defrost,switch.boiler_mandefrost,5,0,1,199,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,pvcooling,cooling only with PV,boolean, ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling,5,0,1,200,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,auxheateronly,aux heater only,boolean, ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly,5,0,1,201,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,auxheateroff,disable aux heater,boolean, ,true,switch.boiler_disable_aux_heater,switch.boiler_auxheateroff,5,0,1,202,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,auxheaterstatus,aux heater status,uint8 (>=0<=100),%,false,sensor.boiler_aux_heater_status,sensor.boiler_auxheaterstatus,5,0,1,203,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,auxheaterdelay,aux heater on delay,uint16 (>=10<=1000),K*min,true,number.boiler_aux_heater_on_delay,number.boiler_auxheaterdelay,5,0,10,204,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,auxmaxlimit,aux heater max limit,uint8 (>=0<=10),K,true,number.boiler_aux_heater_max_limit,number.boiler_auxmaxlimit,5,0,1/10,205,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,auxlimitstart,aux heater limit start,uint8 (>=0<=10),K,true,number.boiler_aux_heater_limit_start,number.boiler_auxlimitstart,5,0,1/10,206,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,auxheatrmode,aux heater mode,enum [eco\|comfort], ,true,select.boiler_aux_heater_mode,select.boiler_auxheatrmode,5,0,1,207,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hphystheat,on/off hyst heat,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_heat,number.boiler_hphystheat,5,0,5,208,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hphystcool,on/off hyst cool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_cool,number.boiler_hphystcool,5,0,5,209,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hphystpool,on/off hyst pool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_pool,number.boiler_hphystpool,5,0,5,210,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,silentmode,silent mode,enum [off\|auto\|on], ,true,select.boiler_silent_mode,select.boiler_silentmode,5,0,1,211,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,silentfrom,silent mode from,uint8 (>=0<=3810),minutes,true,number.boiler_silent_mode_from,number.boiler_silentfrom,5,0,15,212,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,silentto,silent mode to,uint8 (>=0<=3810),minutes,true,number.boiler_silent_mode_to,number.boiler_silentto,5,0,15,213,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,mintempsilent,min outside temp for silent mode,int8 (>=-126<=126),C,true,number.boiler_min_outside_temp_for_silent_mode,number.boiler_mintempsilent,5,0,1,214,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,tempparmode,outside temp parallel mode,int8 (>=-126<=126),C,true,number.boiler_outside_temp_parallel_mode,number.boiler_tempparmode,5,0,1,215,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,auxheatmix,aux heater mixing valve,int8 (>=-100<=100),%,false,sensor.boiler_aux_heater_mixing_valve,sensor.boiler_auxheatmix,5,0,1,216,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,tempdiffheat,temp diff TC3/TC0 heat,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_heat,number.boiler_tempdiffheat,5,0,1/10,217,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,tempdiffcool,temp diff TC3/TC0 cool,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_cool,number.boiler_tempdiffcool,5,0,1/10,218,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,vpcooling,valve/pump cooling,boolean, ,true,switch.boiler_valve/pump_cooling,switch.boiler_vpcooling,5,0,1,219,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,heatcable,heating cable,boolean, ,true,switch.boiler_heating_cable,switch.boiler_heatcable,5,0,1,220,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,vc0valve,VC0 valve,boolean, ,true,switch.boiler_VC0_valve,switch.boiler_vc0valve,5,0,1,221,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,primepump,primary heatpump,boolean, ,true,switch.boiler_primary_heatpump,switch.boiler_primepump,5,0,1,222,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,primepumpmod,primary heatpump modulation,uint8 (>=0<=100),%,true,number.boiler_primary_heatpump_modulation,number.boiler_primepumpmod,5,0,1,223,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hp3way,3-way valve,boolean, ,true,switch.boiler_3-way_valve,switch.boiler_hp3way,5,0,1,224,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,elheatstep1,el. heater step 1,boolean, ,true,switch.boiler_el._heater_step_1,switch.boiler_elheatstep1,5,0,1,225,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,elheatstep2,el. heater step 2,boolean, ,true,switch.boiler_el._heater_step_2,switch.boiler_elheatstep2,5,0,1,226,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,elheatstep3,el. heater step 3,boolean, ,true,switch.boiler_el._heater_step_3,switch.boiler_elheatstep3,5,0,1,227,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hpea0,condensate reservoir heating (EA0),boolean, ,false,binary_sensor.boiler_condensate_reservoir_heating_(EA0),binary_sensor.boiler_hpea0,5,0,1,228,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hppumpmode,primary heatpump mode,enum [auto\|continuous], ,true,select.boiler_primary_heatpump_mode,select.boiler_hppumpmode,5,0,1,229,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,fan,fan,uint8 (>=20<=100),%,true,number.boiler_fan,number.boiler_fan,5,0,1,230,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,shutdown,shutdown,cmd [off\|on], ,true,sensor.boiler_shutdown,sensor.boiler_shutdown,5,0,1,231,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hpcurrpower,compressor current power,uint16 (>=0<=31999),W,false,sensor.boiler_compressor_current_power,sensor.boiler_hpcurrpower,5,0,1,268,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hppowerlimit,power limit,uint16 (>=0<=31999),W,true,number.boiler_power_limit,number.boiler_hppowerlimit,5,0,1,269,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,pc0flow,Flow PC0,int16 (>=-31999<=31999),l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,5,0,1,270,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,pc1flow,Flow PC1,int16 (>=-31999<=31999),l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,5,0,1,271,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,5,0,1,272,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,pc1rate,PC1 rate,uint8 (>=0<=100),%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,5,0,1,273,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,alternatingop,alternating operation,boolean, ,true,switch.boiler_dhw_alternating_operation,switch.boiler_dhw_alternatingop,5,9,1,15,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,altopprioheat,prioritise heating during dhw,uint8 (>=20<=120),minutes,true,number.boiler_dhw_prioritise_heating_during_dhw,number.boiler_dhw_altopprioheat,5,9,1,16,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,altopprio,prioritise dhw during heating,uint8 (>=30<=120),minutes,true,number.boiler_dhw_prioritise_dhw_during_heating,number.boiler_dhw_altopprio,5,9,1,17,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,comfoff,comfort switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_comfort_switch_off,number.boiler_dhw_comfoff,5,9,1,18,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,ecooff,eco switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_eco_switch_off,number.boiler_dhw_ecooff,5,9,1,19,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,ecoplusoff,eco+ switch off,uint8 (>=48<=63),C,true,number.boiler_dhw_eco+_switch_off,number.boiler_dhw_ecoplusoff,5,9,1,20,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,comfdiff,comfort diff,uint8 (>=6<=12),K,true,number.boiler_dhw_comfort_diff,number.boiler_dhw_comfdiff,5,9,1,21,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,ecodiff,eco diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco_diff,number.boiler_dhw_ecodiff,5,9,1,22,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,ecoplusdiff,eco+ diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco+_diff,number.boiler_dhw_ecoplusdiff,5,9,1,23,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,comfstop,comfort stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_comfort_stop_temp,number.boiler_dhw_comfstop,5,9,1,24,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,ecostop,eco stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco_stop_temp,number.boiler_dhw_ecostop,5,9,1,25,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,ecoplusstop,eco+ stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco+_stop_temp,number.boiler_dhw_ecoplusstop,5,9,1,26,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hpcircpump,circulation pump available during dhw,boolean, ,true,switch.boiler_dhw_circulation_pump_available_during_dhw,switch.boiler_dhw_hpcircpump,5,9,1,27,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i,boiler,172,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 Geo 5xx,boiler,173,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 Geo 5xx,boiler,173,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 Geo 5xx,boiler,173,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 @@ -2279,6 +2300,7 @@ Geo 5xx,boiler,173,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,numb Geo 5xx,boiler,173,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 Geo 5xx,boiler,173,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 Geo 5xx,boiler,173,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 +Geo 5xx,boiler,173,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1 Geo 5xx,boiler,173,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 Geo 5xx,boiler,173,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 Geo 5xx,boiler,173,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 @@ -2334,6 +2356,7 @@ Geo 5xx,boiler,173,nrgsuppcooling,total energy supplied cooling,uint24 (>=0<=167 Geo 5xx,boiler,173,nrgsupppool,total energy supplied pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool,5,0,1,132,2 Geo 5xx,boiler,173,hppower,compressor power output,uint8 (>=0<=25),kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower,5,0,1/10,134,1 Geo 5xx,boiler,173,hpmaxpower,compressor max power,uint8 (>=0<=100),%,true,number.boiler_compressor_max_power,number.boiler_hpmaxpower,5,0,1,135,1 +Geo 5xx,boiler,173,pvmaxcomp,pv compressor max power,uint8 (>=0<=25),kW,true,number.boiler_pv_compressor_max_power,number.boiler_pvmaxcomp,5,0,1/10,-1,1 Geo 5xx,boiler,173,hpsetdiffpress,set differental pressure,uint8 (>=150<=750),mbar,true,number.boiler_set_differental_pressure,number.boiler_hpsetdiffpress,5,0,50,136,1 Geo 5xx,boiler,173,hpcompon,hp compressor,boolean, ,false,binary_sensor.boiler_hp_compressor,binary_sensor.boiler_hpcompon,5,0,1,137,1 Geo 5xx,boiler,173,hpactivity,compressor activity,enum [none\|heating\|cooling\|hot water\|pool\|unknown\|defrost], ,false,sensor.boiler_compressor_activity,sensor.boiler_hpactivity,5,0,1,138,1 @@ -2461,224 +2484,226 @@ Geo 5xx,boiler,173,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor Geo 5xx,boiler,173,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 Geo 5xx,boiler,173,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 Geo 5xx,boiler,173,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,5,0,1/10,232,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,5,0,1,233,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,5,0,1,234,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,5,0,1/10,235,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,5,0,1,236,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,5,0,1,237,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,5,0,1,238,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,5,0,1,239,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,5,0,1,240,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,5,0,1,241,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,5,0,1,242,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock,5,0,1/10,243,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,5,0,1,244,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,5,0,1,245,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,5,0,1,246,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,5,0,1,247,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,5,0,1,248,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,5,0,1,249,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,5,0,1,250,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,5,0,1,251,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,5,0,1,252,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,5,0,1,253,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,90,2 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,254,2 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,256,2 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,258,1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2 -Logamax U122/Cerapur,boiler,203,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 -Logamax U122/Cerapur,boiler,203,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 -Logamax U122/Cerapur,boiler,203,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 -Logamax U122/Cerapur,boiler,203,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 -Logamax U122/Cerapur,boiler,203,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 -Logamax U122/Cerapur,boiler,203,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 -Logamax U122/Cerapur,boiler,203,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 -Logamax U122/Cerapur,boiler,203,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 -Logamax U122/Cerapur,boiler,203,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 -Logamax U122/Cerapur,boiler,203,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 -Logamax U122/Cerapur,boiler,203,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 -Logamax U122/Cerapur,boiler,203,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 -Logamax U122/Cerapur,boiler,203,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 -Logamax U122/Cerapur,boiler,203,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,5,0,1/10,232,1 -Logamax U122/Cerapur,boiler,203,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,5,0,1,233,1 -Logamax U122/Cerapur,boiler,203,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,5,0,1,234,1 -Logamax U122/Cerapur,boiler,203,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,5,0,1/10,235,1 -Logamax U122/Cerapur,boiler,203,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,5,0,1,236,1 -Logamax U122/Cerapur,boiler,203,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,5,0,1,237,1 -Logamax U122/Cerapur,boiler,203,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,5,0,1,238,1 -Logamax U122/Cerapur,boiler,203,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,5,0,1,239,1 -Logamax U122/Cerapur,boiler,203,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,5,0,1,240,1 -Logamax U122/Cerapur,boiler,203,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,5,0,1,241,1 -Logamax U122/Cerapur,boiler,203,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,5,0,1,242,1 -Logamax U122/Cerapur,boiler,203,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock,5,0,1/10,243,1 -Logamax U122/Cerapur,boiler,203,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,5,0,1,244,1 -Logamax U122/Cerapur,boiler,203,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,5,0,1,245,1 -Logamax U122/Cerapur,boiler,203,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,5,0,1,246,1 -Logamax U122/Cerapur,boiler,203,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,5,0,1,247,1 -Logamax U122/Cerapur,boiler,203,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,5,0,1,248,1 -Logamax U122/Cerapur,boiler,203,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,5,0,1,249,1 -Logamax U122/Cerapur,boiler,203,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,5,0,1,250,1 -Logamax U122/Cerapur,boiler,203,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,5,0,1,251,1 -Logamax U122/Cerapur,boiler,203,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,5,0,1,252,1 -Logamax U122/Cerapur,boiler,203,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,5,0,1,253,1 -Logamax U122/Cerapur,boiler,203,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 -Logamax U122/Cerapur,boiler,203,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 -Logamax U122/Cerapur,boiler,203,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 -Logamax U122/Cerapur,boiler,203,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 -Logamax U122/Cerapur,boiler,203,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 -Logamax U122/Cerapur,boiler,203,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 -Logamax U122/Cerapur,boiler,203,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 -Logamax U122/Cerapur,boiler,203,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 -Logamax U122/Cerapur,boiler,203,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 -Logamax U122/Cerapur,boiler,203,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 -Logamax U122/Cerapur,boiler,203,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 -Logamax U122/Cerapur,boiler,203,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2 -Logamax U122/Cerapur,boiler,203,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2 -Logamax U122/Cerapur,boiler,203,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2 -Logamax U122/Cerapur,boiler,203,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2 -Logamax U122/Cerapur,boiler,203,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2 -Logamax U122/Cerapur,boiler,203,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28 -Logamax U122/Cerapur,boiler,203,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2 -Logamax U122/Cerapur,boiler,203,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1 -Logamax U122/Cerapur,boiler,203,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2 -Logamax U122/Cerapur,boiler,203,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1 -Logamax U122/Cerapur,boiler,203,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1 -Logamax U122/Cerapur,boiler,203,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6 -Logamax U122/Cerapur,boiler,203,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1 -Logamax U122/Cerapur,boiler,203,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1 -Logamax U122/Cerapur,boiler,203,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,90,2 -Logamax U122/Cerapur,boiler,203,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 -Logamax U122/Cerapur,boiler,203,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,254,2 -Logamax U122/Cerapur,boiler,203,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 -Logamax U122/Cerapur,boiler,203,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,256,2 -Logamax U122/Cerapur,boiler,203,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 -Logamax U122/Cerapur,boiler,203,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 -Logamax U122/Cerapur,boiler,203,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 -Logamax U122/Cerapur,boiler,203,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 -Logamax U122/Cerapur,boiler,203,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 -Logamax U122/Cerapur,boiler,203,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 -Logamax U122/Cerapur,boiler,203,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 -Logamax U122/Cerapur,boiler,203,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 -Logamax U122/Cerapur,boiler,203,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 -Logamax U122/Cerapur,boiler,203,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 -Logamax U122/Cerapur,boiler,203,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 -Logamax U122/Cerapur,boiler,203,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 -Logamax U122/Cerapur,boiler,203,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 -Logamax U122/Cerapur,boiler,203,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 -Logamax U122/Cerapur,boiler,203,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 -Logamax U122/Cerapur,boiler,203,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 -Logamax U122/Cerapur,boiler,203,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 -Logamax U122/Cerapur,boiler,203,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 -Logamax U122/Cerapur,boiler,203,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 -Logamax U122/Cerapur,boiler,203,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 -Logamax U122/Cerapur,boiler,203,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 -Logamax U122/Cerapur,boiler,203,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 -Logamax U122/Cerapur,boiler,203,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 -Logamax U122/Cerapur,boiler,203,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 -Logamax U122/Cerapur,boiler,203,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 -Logamax U122/Cerapur,boiler,203,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 -Logamax U122/Cerapur,boiler,203,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 -Logamax U122/Cerapur,boiler,203,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 -Logamax U122/Cerapur,boiler,203,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 -Logamax U122/Cerapur,boiler,203,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 -Logamax U122/Cerapur,boiler,203,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 -Logamax U122/Cerapur,boiler,203,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 -Logamax U122/Cerapur,boiler,203,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 -Logamax U122/Cerapur,boiler,203,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 -Logamax U122/Cerapur,boiler,203,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 -Logamax U122/Cerapur,boiler,203,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -Logamax U122/Cerapur,boiler,203,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 -Logamax U122/Cerapur,boiler,203,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 -Logamax U122/Cerapur,boiler,203,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 -Logamax U122/Cerapur,boiler,203,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 -Logamax U122/Cerapur,boiler,203,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,258,1 -Logamax U122/Cerapur,boiler,203,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 -Logamax U122/Cerapur,boiler,203,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2 -Logamax U122/Cerapur,boiler,203,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,5,0,1/10,232,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,5,0,1,233,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,5,0,1,234,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,5,0,1/10,235,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,5,0,1,236,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,5,0,1,237,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,5,0,1,238,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,5,0,1,239,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,5,0,1,240,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,5,0,1,241,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,5,0,1,242,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock,5,0,1/10,243,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,5,0,1,244,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,5,0,1,245,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,5,0,1,246,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,5,0,1,247,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,5,0,1,248,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,5,0,1,249,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,5,0,1,250,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,5,0,1,251,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,5,0,1,252,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,5,0,1,253,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,90,2 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,254,2 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,256,2 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,258,1 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2 +Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2,boiler,195,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2 +Logamax U122, Cerapur,boiler,203,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 +Logamax U122, Cerapur,boiler,203,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 +Logamax U122, Cerapur,boiler,203,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 +Logamax U122, Cerapur,boiler,203,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 +Logamax U122, Cerapur,boiler,203,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 +Logamax U122, Cerapur,boiler,203,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 +Logamax U122, Cerapur,boiler,203,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 +Logamax U122, Cerapur,boiler,203,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 +Logamax U122, Cerapur,boiler,203,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 +Logamax U122, Cerapur,boiler,203,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 +Logamax U122, Cerapur,boiler,203,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 +Logamax U122, Cerapur,boiler,203,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 +Logamax U122, Cerapur,boiler,203,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 +Logamax U122, Cerapur,boiler,203,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,5,0,1/10,232,1 +Logamax U122, Cerapur,boiler,203,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,5,0,1,233,1 +Logamax U122, Cerapur,boiler,203,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,5,0,1,234,1 +Logamax U122, Cerapur,boiler,203,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,5,0,1/10,235,1 +Logamax U122, Cerapur,boiler,203,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,5,0,1,236,1 +Logamax U122, Cerapur,boiler,203,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,5,0,1,237,1 +Logamax U122, Cerapur,boiler,203,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,5,0,1,238,1 +Logamax U122, Cerapur,boiler,203,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,5,0,1,239,1 +Logamax U122, Cerapur,boiler,203,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,5,0,1,240,1 +Logamax U122, Cerapur,boiler,203,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,5,0,1,241,1 +Logamax U122, Cerapur,boiler,203,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,5,0,1,242,1 +Logamax U122, Cerapur,boiler,203,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock,5,0,1/10,243,1 +Logamax U122, Cerapur,boiler,203,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,5,0,1,244,1 +Logamax U122, Cerapur,boiler,203,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,5,0,1,245,1 +Logamax U122, Cerapur,boiler,203,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,5,0,1,246,1 +Logamax U122, Cerapur,boiler,203,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,5,0,1,247,1 +Logamax U122, Cerapur,boiler,203,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,5,0,1,248,1 +Logamax U122, Cerapur,boiler,203,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,5,0,1,249,1 +Logamax U122, Cerapur,boiler,203,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,5,0,1,250,1 +Logamax U122, Cerapur,boiler,203,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,5,0,1,251,1 +Logamax U122, Cerapur,boiler,203,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,5,0,1,252,1 +Logamax U122, Cerapur,boiler,203,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,5,0,1,253,1 +Logamax U122, Cerapur,boiler,203,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 +Logamax U122, Cerapur,boiler,203,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 +Logamax U122, Cerapur,boiler,203,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 +Logamax U122, Cerapur,boiler,203,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 +Logamax U122, Cerapur,boiler,203,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 +Logamax U122, Cerapur,boiler,203,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 +Logamax U122, Cerapur,boiler,203,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 +Logamax U122, Cerapur,boiler,203,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 +Logamax U122, Cerapur,boiler,203,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1 +Logamax U122, Cerapur,boiler,203,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 +Logamax U122, Cerapur,boiler,203,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 +Logamax U122, Cerapur,boiler,203,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 +Logamax U122, Cerapur,boiler,203,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2 +Logamax U122, Cerapur,boiler,203,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2 +Logamax U122, Cerapur,boiler,203,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2 +Logamax U122, Cerapur,boiler,203,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2 +Logamax U122, Cerapur,boiler,203,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2 +Logamax U122, Cerapur,boiler,203,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28 +Logamax U122, Cerapur,boiler,203,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2 +Logamax U122, Cerapur,boiler,203,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1 +Logamax U122, Cerapur,boiler,203,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2 +Logamax U122, Cerapur,boiler,203,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1 +Logamax U122, Cerapur,boiler,203,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1 +Logamax U122, Cerapur,boiler,203,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6 +Logamax U122, Cerapur,boiler,203,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1 +Logamax U122, Cerapur,boiler,203,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1 +Logamax U122, Cerapur,boiler,203,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,90,2 +Logamax U122, Cerapur,boiler,203,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 +Logamax U122, Cerapur,boiler,203,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,254,2 +Logamax U122, Cerapur,boiler,203,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 +Logamax U122, Cerapur,boiler,203,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,256,2 +Logamax U122, Cerapur,boiler,203,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 +Logamax U122, Cerapur,boiler,203,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 +Logamax U122, Cerapur,boiler,203,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 +Logamax U122, Cerapur,boiler,203,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 +Logamax U122, Cerapur,boiler,203,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 +Logamax U122, Cerapur,boiler,203,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 +Logamax U122, Cerapur,boiler,203,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 +Logamax U122, Cerapur,boiler,203,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 +Logamax U122, Cerapur,boiler,203,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 +Logamax U122, Cerapur,boiler,203,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 +Logamax U122, Cerapur,boiler,203,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 +Logamax U122, Cerapur,boiler,203,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 +Logamax U122, Cerapur,boiler,203,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 +Logamax U122, Cerapur,boiler,203,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 +Logamax U122, Cerapur,boiler,203,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 +Logamax U122, Cerapur,boiler,203,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 +Logamax U122, Cerapur,boiler,203,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 +Logamax U122, Cerapur,boiler,203,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 +Logamax U122, Cerapur,boiler,203,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 +Logamax U122, Cerapur,boiler,203,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 +Logamax U122, Cerapur,boiler,203,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 +Logamax U122, Cerapur,boiler,203,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 +Logamax U122, Cerapur,boiler,203,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 +Logamax U122, Cerapur,boiler,203,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 +Logamax U122, Cerapur,boiler,203,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 +Logamax U122, Cerapur,boiler,203,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 +Logamax U122, Cerapur,boiler,203,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 +Logamax U122, Cerapur,boiler,203,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 +Logamax U122, Cerapur,boiler,203,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 +Logamax U122, Cerapur,boiler,203,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 +Logamax U122, Cerapur,boiler,203,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 +Logamax U122, Cerapur,boiler,203,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 +Logamax U122, Cerapur,boiler,203,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 +Logamax U122, Cerapur,boiler,203,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 +Logamax U122, Cerapur,boiler,203,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 +Logamax U122, Cerapur,boiler,203,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 +Logamax U122, Cerapur,boiler,203,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +Logamax U122, Cerapur,boiler,203,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +Logamax U122, Cerapur,boiler,203,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +Logamax U122, Cerapur,boiler,203,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 +Logamax U122, Cerapur,boiler,203,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,258,1 +Logamax U122, Cerapur,boiler,203,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 +Logamax U122, Cerapur,boiler,203,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2 +Logamax U122, Cerapur,boiler,203,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2 Ecomline Excellent,boiler,206,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 Ecomline Excellent,boiler,206,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 Ecomline Excellent,boiler,206,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 @@ -2722,6 +2747,7 @@ Ecomline Excellent,boiler,206,pumpmodmin,boiler pump min power,uint8 (>=0<=100), Ecomline Excellent,boiler,206,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 Ecomline Excellent,boiler,206,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 Ecomline Excellent,boiler,206,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 +Ecomline Excellent,boiler,206,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1 Ecomline Excellent,boiler,206,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 Ecomline Excellent,boiler,206,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 Ecomline Excellent,boiler,206,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 @@ -2788,115 +2814,116 @@ Ecomline Excellent,boiler,206,nompower,nominal Power,uint8 (>=0<=254),kW,true,nu Ecomline Excellent,boiler,206,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 Ecomline Excellent,boiler,206,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2 Ecomline Excellent,boiler,206,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,5,0,1/10,232,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,5,0,1,233,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,5,0,1,234,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,5,0,1/10,235,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,5,0,1,236,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,5,0,1,237,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,5,0,1,238,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,5,0,1,239,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,5,0,1,240,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,5,0,1,241,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,5,0,1,242,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock,5,0,1/10,243,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,5,0,1,244,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,5,0,1,245,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,5,0,1,246,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,5,0,1,247,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,5,0,1,248,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,5,0,1,249,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,5,0,1,250,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,5,0,1,251,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,5,0,1,252,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,5,0,1,253,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,90,2 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,254,2 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,256,2 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,258,1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,5,0,1/10,232,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,5,0,1,233,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,5,0,1,234,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,5,0,1/10,235,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,5,0,1,236,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,5,0,1,237,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,5,0,1,238,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,5,0,1,239,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,5,0,1,240,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,5,0,1,241,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,5,0,1,242,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock,5,0,1/10,243,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,5,0,1,244,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,5,0,1,245,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,5,0,1,246,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,5,0,1,247,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,5,0,1,248,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,5,0,1,249,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,5,0,1,250,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,5,0,1,251,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,5,0,1,252,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,5,0,1,253,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,90,2 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,254,2 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,256,2 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,258,1 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2 +Logamax Plus, GB192, Condens GC9000, Greenstar ErP,boiler,208,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2 Cascade MC400,boiler,210,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 Cascade MC400,boiler,210,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 Cascade MC400,boiler,210,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 @@ -2940,6 +2967,7 @@ Cascade MC400,boiler,210,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,tru Cascade MC400,boiler,210,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 Cascade MC400,boiler,210,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 Cascade MC400,boiler,210,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 +Cascade MC400,boiler,210,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1 Cascade MC400,boiler,210,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 Cascade MC400,boiler,210,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 Cascade MC400,boiler,210,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 @@ -3049,6 +3077,7 @@ EasyControl Adapter,boiler,211,pumpmodmin,boiler pump min power,uint8 (>=0<=100) EasyControl Adapter,boiler,211,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 EasyControl Adapter,boiler,211,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 EasyControl Adapter,boiler,211,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 +EasyControl Adapter,boiler,211,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1 EasyControl Adapter,boiler,211,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 EasyControl Adapter,boiler,211,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 EasyControl Adapter,boiler,211,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 @@ -3115,301 +3144,303 @@ EasyControl Adapter,boiler,211,nompower,nominal Power,uint8 (>=0<=254),kW,true,n EasyControl Adapter,boiler,211,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 EasyControl Adapter,boiler,211,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2 EasyControl Adapter,boiler,211,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2 -Greenstar HIU/Logamax kompakt WS170,boiler,219,netflowtemp,heat network flow temp,uint16 (>=0<=3199),C,false,sensor.boiler_heat_network_flow_temp,sensor.boiler_netflowtemp,5,0,1/10,259,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,heatvalve,heating valve,uint8 (>=0<=100),%,false,sensor.boiler_heating_valve,sensor.boiler_heatvalve,5,0,1,260,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,dhwvalve,valve,uint8 (>=0<=100),%,false,sensor.boiler_dhw_valve,sensor.boiler_dhw_dhwvalve,5,9,1,74,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,keepwarmtemp,keep warm temperature,uint8 (>=0<=254),C,true,number.boiler_keep_warm_temperature,number.boiler_keepwarmtemp,5,0,1,261,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,setreturntemp,set temp return,uint8 (>=0<=254),C,true,number.boiler_set_temp_return,number.boiler_setreturntemp,5,0,1,262,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,heating,heating,boolean, ,false,binary_sensor.boiler_heating,binary_sensor.boiler_heating,5,0,1,263,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 -Greenstar HIU/Logamax kompakt WS170,boiler,219,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2 -Greenstar HIU/Logamax kompakt WS170,boiler,219,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2 -Greenstar HIU/Logamax kompakt WS170,boiler,219,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2 -Greenstar HIU/Logamax kompakt WS170,boiler,219,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2 -Greenstar HIU/Logamax kompakt WS170,boiler,219,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2 -Greenstar HIU/Logamax kompakt WS170,boiler,219,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28 -Greenstar HIU/Logamax kompakt WS170,boiler,219,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2 -Greenstar HIU/Logamax kompakt WS170,boiler,219,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2 -Greenstar HIU/Logamax kompakt WS170,boiler,219,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6 -Greenstar HIU/Logamax kompakt WS170,boiler,219,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,90,2 -Greenstar HIU/Logamax kompakt WS170,boiler,219,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 -Greenstar HIU/Logamax kompakt WS170,boiler,219,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,254,2 -Greenstar HIU/Logamax kompakt WS170,boiler,219,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 -Greenstar HIU/Logamax kompakt WS170,boiler,219,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,256,2 -Greenstar HIU/Logamax kompakt WS170,boiler,219,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 -Greenstar HIU/Logamax kompakt WS170,boiler,219,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 -Greenstar HIU/Logamax kompakt WS170,boiler,219,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,5,0,1/10,232,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,5,0,1,233,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,5,0,1,234,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,5,0,1/10,235,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,5,0,1,236,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,5,0,1,237,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,5,0,1,238,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,5,0,1,239,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,5,0,1,240,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,5,0,1,241,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,5,0,1,242,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock,5,0,1/10,243,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,5,0,1,244,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,5,0,1,245,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,5,0,1,246,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,5,0,1,247,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,5,0,1,248,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,5,0,1,249,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,5,0,1,250,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,5,0,1,251,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,5,0,1,252,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,5,0,1,253,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,90,2 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,254,2 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,256,2 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,258,1 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2 -Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2 -Logamatic TC100/Moduline Easy,thermostat,202,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 -Logamatic TC100/Moduline Easy,thermostat,202,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 -Logamatic TC100/Moduline Easy,thermostat,202,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 -Logamatic TC100/Moduline Easy,thermostat,202,seltemp,selected room temperature,int16 (>=-319<=319),C,false,sensor.thermostat_hc1_selected_room_temperature,sensor.thermostat_hc1_seltemp,6,1,1/100,0,1 -Logamatic TC100/Moduline Easy,thermostat,202,currtemp,current room temperature,int16 (>=-319<=319),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/100,1,1 -Logamatic TC100/Moduline Easy,thermostat,202,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 -EasyControl/CT200,thermostat,203,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 -EasyControl/CT200,thermostat,203,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 -EasyControl/CT200,thermostat,203,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 -EasyControl/CT200,thermostat,203,seltemp,selected room temperature,int16 (>=-319<=319),C,false,sensor.thermostat_hc1_selected_room_temperature,sensor.thermostat_hc1_seltemp,6,1,1/100,0,1 -EasyControl/CT200,thermostat,203,currtemp,current room temperature,int16 (>=-319<=319),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/100,1,1 -EasyControl/CT200,thermostat,203,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 -UI800/BC400,thermostat,4,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 -UI800/BC400,thermostat,4,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 -UI800/BC400,thermostat,4,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 -UI800/BC400,thermostat,4,intoffset,internal temperature offset,int8 (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset,6,0,1/10,46,1 -UI800/BC400,thermostat,4,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry,6,0,1,47,1 -UI800/BC400,thermostat,4,dampedoutdoortemp,damped outdoor temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp,6,0,1/10,48,1 -UI800/BC400,thermostat,4,floordrytemp,floor drying temperature,uint8 (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp,6,0,1,49,1 -UI800/BC400,thermostat,4,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building,6,0,1,50,1 -UI800/BC400,thermostat,4,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp,6,0,1,51,1 -UI800/BC400,thermostat,4,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping,6,0,1,52,1 -UI800/BC400,thermostat,4,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy,6,0,1,53,1 -UI800/BC400,thermostat,4,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp,6,0,1,54,1 -UI800/BC400,thermostat,4,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio,6,0,1/10,55,1 -UI800/BC400,thermostat,4,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor,6,0,1/10,56,1 -UI800/BC400,thermostat,4,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor,6,0,1/10,57,1 -UI800/BC400,thermostat,4,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler,6,0,1,58,1 -UI800/BC400,thermostat,4,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler,6,0,1,59,1 -UI800/BC400,thermostat,4,pvenabledhw,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenabledhw,6,0,1,60,1 -UI800/BC400,thermostat,4,pvraiseheat,raise heating with PV,int8 (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat,6,0,1,61,1 -UI800/BC400,thermostat,4,pvlowercool,lower cooling with PV,int8 (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool,6,0,1,62,1 -UI800/BC400,thermostat,4,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp,6,1,1/2,0,1 -UI800/BC400,thermostat,4,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/10,1,1 -UI800/BC400,thermostat,4,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 -UI800/BC400,thermostat,4,mode,operating mode,enum [off\|manual\|auto], ,true,select.thermostat_hc1_operating_mode,select.thermostat_hc1_mode,6,1,1,3,1 -UI800/BC400,thermostat,4,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype,6,1,1,4,1 -UI800/BC400,thermostat,4,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp,6,1,1/2,5,1 -UI800/BC400,thermostat,4,manualtemp,manual temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp,6,1,1/2,6,1 -UI800/BC400,thermostat,4,comforttemp,comfort temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp,6,1,1/2,7,1 -UI800/BC400,thermostat,4,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 -UI800/BC400,thermostat,4,designtemp,design temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp,6,1,1,9,1 -UI800/BC400,thermostat,4,offsettemp,offset temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp,6,1,1,10,1 -UI800/BC400,thermostat,4,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp,6,1,1,11,1 -UI800/BC400,thermostat,4,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp,6,1,1,12,1 -UI800/BC400,thermostat,4,roominfluence,room influence,uint8 (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence,6,1,1,13,1 -UI800/BC400,thermostat,4,roominflfactor,room influence factor,uint8 (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor,6,1,1/10,14,1 -UI800/BC400,thermostat,4,curroominfl,current room influence,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl,6,1,1/10,15,1 -UI800/BC400,thermostat,4,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode,6,1,1,16,1 -UI800/BC400,thermostat,4,nofrosttemp,nofrost temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp,6,1,1,17,1 -UI800/BC400,thermostat,4,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp,6,1,1,18,1 -UI800/BC400,thermostat,4,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype,6,1,1,19,1 -UI800/BC400,thermostat,4,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode,6,1,1,20,1 -UI800/BC400,thermostat,4,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode,6,1,1,21,1 -UI800/BC400,thermostat,4,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode,6,1,1,22,1 -UI800/BC400,thermostat,4,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate,6,1,1,23,1 -UI800/BC400,thermostat,4,controlmode,control mode,enum [weather compensated\|outside basepoint\|n/a\|room\|power\|constant], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode,6,1,1,24,1 -UI800/BC400,thermostat,4,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program,6,1,1,25,1 -UI800/BC400,thermostat,4,tempautotemp,temporary set temperature automode,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp,6,1,1/2,26,1 -UI800/BC400,thermostat,4,remoteseltemp,temporary set temperature from remote,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_from_remote,number.thermostat_hc1_remoteseltemp,6,1,1/2,27,1 -UI800/BC400,thermostat,4,fastheatup,fast heatup,uint8 (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup,6,1,1,28,1 -UI800/BC400,thermostat,4,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization,6,1,1,29,1 -UI800/BC400,thermostat,4,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode,6,1,1,30,1 -UI800/BC400,thermostat,4,noreducetemp,no reduce below temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp,6,1,1,31,1 -UI800/BC400,thermostat,4,reducetemp,off/reduce switch temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp,6,1,1,32,1 -UI800/BC400,thermostat,4,dhwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_dhwprio,6,1,1,33,1 -UI800/BC400,thermostat,4,hpcooling,hp cooling,boolean, ,true,switch.thermostat_hc1_hp_cooling,switch.thermostat_hc1_hpcooling,6,1,1,34,1 -UI800/BC400,thermostat,4,coolingon,cooling on,boolean, ,false,binary_sensor.thermostat_hc1_cooling_on,binary_sensor.thermostat_hc1_coolingon,6,1,1,35,1 -UI800/BC400,thermostat,4,hpmode,HP Mode,enum [heating\|cooling\|heating & cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode,6,1,1,36,1 -UI800/BC400,thermostat,4,dewoffset,dew point offset,uint8 (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset,6,1,1,37,1 -UI800/BC400,thermostat,4,roomtempdiff,room temp difference,uint8 (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff,6,1,1,38,1 -UI800/BC400,thermostat,4,hpminflowtemp,HP min. flow temp.,uint8 (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp,6,1,1,39,1 -UI800/BC400,thermostat,4,control,control device,enum [off\|-\|RC100\|RC100H\|-\|RC120RF\|RC220/RT800\|single], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control,6,1,1,40,1 -UI800/BC400,thermostat,4,remotetemp,room temperature from remote,cmd [] (>=-1<=101),C,true,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp,6,1,1/10,41,1 -UI800/BC400,thermostat,4,remotehum,room humidity from remote,cmd [] (>=-1<=101),%,true,sensor.thermostat_hc1_room_humidity_from_remote,sensor.thermostat_hc1_remotehum,6,1,1,42,1 -UI800/BC400,thermostat,4,heatondelay,heat-on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay,6,1,1,43,1 -UI800/BC400,thermostat,4,heatoffdelay,heat-off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay,6,1,1,44,1 -UI800/BC400,thermostat,4,instantstart,instant start,uint8 (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart,6,1,1,45,1 -UI800/BC400,thermostat,4,boost,boost mode,boolean, ,true,switch.thermostat_hc1_boost_mode,switch.thermostat_hc1_boost,6,1,1,46,1 -UI800/BC400,thermostat,4,boosttime,boost time,uint8 (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime,6,1,1,47,1 -UI800/BC400,thermostat,4,coolstart,cooling starttemp,uint8 (>=20<=35),C,true,number.thermostat_hc1_cooling_starttemp,number.thermostat_hc1_coolstart,6,1,1,193,1 -UI800/BC400,thermostat,4,coolondelay,cooling on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_on_delay,number.thermostat_hc1_coolondelay,6,1,1,194,1 -UI800/BC400,thermostat,4,cooloffdelay,cooling off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_off_delay,number.thermostat_hc1_cooloffdelay,6,1,1,195,1 -UI800/BC400,thermostat,4,switchprogmode,switch program mode,enum [level\|absolute], ,true,select.thermostat_hc1_switch_program_mode,select.thermostat_hc1_switchprogmode,6,1,1,196,1 -UI800/BC400,thermostat,4,mode,operating mode,enum [off\|eco+\|eco\|comfort\|auto], ,true,select.thermostat_dhw_operating_mode,select.thermostat_dhw_mode,6,9,1,0,1 -UI800/BC400,thermostat,4,settemp,set temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_temperature,number.thermostat_dhw_settemp,6,9,1,1,1 -UI800/BC400,thermostat,4,settemplow,set low temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_low_temperature,number.thermostat_dhw_settemplow,6,9,1,2,1 -UI800/BC400,thermostat,4,circmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_dhw_circulation_pump_mode,select.thermostat_dhw_circmode,6,9,1,3,1 -UI800/BC400,thermostat,4,chargeduration,charge duration,uint8 (>=0<=3810),minutes,true,number.thermostat_dhw_charge_duration,number.thermostat_dhw_chargeduration,6,9,15,4,1 -UI800/BC400,thermostat,4,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge,6,9,1,5,1 -UI800/BC400,thermostat,4,extra,extra,uint8 (>=0<=254),C,false,sensor.thermostat_dhw_extra,sensor.thermostat_dhw_extra,6,9,1,6,1 -UI800/BC400,thermostat,4,disinfecting,disinfecting,boolean, ,true,switch.thermostat_dhw_disinfecting,switch.thermostat_dhw_disinfecting,6,9,1,7,1 -UI800/BC400,thermostat,4,disinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_dhw_disinfection_day,select.thermostat_dhw_disinfectday,6,9,1,8,1 -UI800/BC400,thermostat,4,disinfecttime,disinfection time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_disinfection_time,number.thermostat_dhw_disinfecttime,6,9,15,9,1 -UI800/BC400,thermostat,4,dailyheating,daily heating,boolean, ,true,switch.thermostat_dhw_daily_heating,switch.thermostat_dhw_dailyheating,6,9,1,10,1 -UI800/BC400,thermostat,4,dailyheattime,daily heating time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_daily_heating_time,number.thermostat_dhw_dailyheattime,6,9,15,11,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,netflowtemp,heat network flow temp,uint16 (>=0<=3199),C,false,sensor.boiler_heat_network_flow_temp,sensor.boiler_netflowtemp,5,0,1/10,259,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,heatvalve,heating valve,uint8 (>=0<=100),%,false,sensor.boiler_heating_valve,sensor.boiler_heatvalve,5,0,1,260,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,dhwvalve,valve,uint8 (>=0<=100),%,false,sensor.boiler_dhw_valve,sensor.boiler_dhw_dhwvalve,5,9,1,74,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,keepwarmtemp,keep warm temperature,uint8 (>=0<=254),C,true,number.boiler_keep_warm_temperature,number.boiler_keepwarmtemp,5,0,1,261,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,setreturntemp,set temp return,uint8 (>=0<=254),C,true,number.boiler_set_temp_return,number.boiler_setreturntemp,5,0,1,262,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,heating,heating,boolean, ,false,binary_sensor.boiler_heating,binary_sensor.boiler_heating,5,0,1,263,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 +Greenstar HIU, Logamax kompakt WS170,boiler,219,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2 +Greenstar HIU, Logamax kompakt WS170,boiler,219,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2 +Greenstar HIU, Logamax kompakt WS170,boiler,219,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2 +Greenstar HIU, Logamax kompakt WS170,boiler,219,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2 +Greenstar HIU, Logamax kompakt WS170,boiler,219,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2 +Greenstar HIU, Logamax kompakt WS170,boiler,219,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28 +Greenstar HIU, Logamax kompakt WS170,boiler,219,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2 +Greenstar HIU, Logamax kompakt WS170,boiler,219,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2 +Greenstar HIU, Logamax kompakt WS170,boiler,219,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6 +Greenstar HIU, Logamax kompakt WS170,boiler,219,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,90,2 +Greenstar HIU, Logamax kompakt WS170,boiler,219,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 +Greenstar HIU, Logamax kompakt WS170,boiler,219,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,254,2 +Greenstar HIU, Logamax kompakt WS170,boiler,219,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 +Greenstar HIU, Logamax kompakt WS170,boiler,219,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,256,2 +Greenstar HIU, Logamax kompakt WS170,boiler,219,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 +Greenstar HIU, Logamax kompakt WS170,boiler,219,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +Greenstar HIU, Logamax kompakt WS170,boiler,219,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +Greenstar HIU, Logamax kompakt WS170,boiler,219,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,5,0,1/10,232,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,5,0,1,233,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,5,0,1,234,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,5,0,1/10,235,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,5,0,1,236,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,5,0,1,237,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,5,0,1,238,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,5,0,1,239,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,5,0,1,240,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,5,0,1,241,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,5,0,1,242,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock,5,0,1/10,243,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,5,0,1,244,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,5,0,1,245,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,5,0,1,246,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,5,0,1,247,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,5,0,1,248,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,5,0,1,249,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,5,0,1,250,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,5,0,1,251,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,5,0,1,252,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,5,0,1,253,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,-1,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,90,2 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,254,2 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,256,2 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,258,1 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2 +Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W,boiler,234,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2 +Logamatic TC100, Moduline Easy,thermostat,202,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 +Logamatic TC100, Moduline Easy,thermostat,202,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 +Logamatic TC100, Moduline Easy,thermostat,202,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 +Logamatic TC100, Moduline Easy,thermostat,202,seltemp,selected room temperature,int16 (>=-319<=319),C,false,sensor.thermostat_hc1_selected_room_temperature,sensor.thermostat_hc1_seltemp,6,1,1/100,0,1 +Logamatic TC100, Moduline Easy,thermostat,202,currtemp,current room temperature,int16 (>=-319<=319),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/100,1,1 +Logamatic TC100, Moduline Easy,thermostat,202,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 +EasyControl, CT200,thermostat,203,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 +EasyControl, CT200,thermostat,203,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 +EasyControl, CT200,thermostat,203,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 +EasyControl, CT200,thermostat,203,seltemp,selected room temperature,int16 (>=-319<=319),C,false,sensor.thermostat_hc1_selected_room_temperature,sensor.thermostat_hc1_seltemp,6,1,1/100,0,1 +EasyControl, CT200,thermostat,203,currtemp,current room temperature,int16 (>=-319<=319),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/100,1,1 +EasyControl, CT200,thermostat,203,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 +UI800, BC400,thermostat,4,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 +UI800, BC400,thermostat,4,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 +UI800, BC400,thermostat,4,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 +UI800, BC400,thermostat,4,intoffset,internal temperature offset,int8 (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset,6,0,1/10,46,1 +UI800, BC400,thermostat,4,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry,6,0,1,47,1 +UI800, BC400,thermostat,4,dampedoutdoortemp,damped outdoor temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp,6,0,1/10,48,1 +UI800, BC400,thermostat,4,floordrytemp,floor drying temperature,uint8 (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp,6,0,1,49,1 +UI800, BC400,thermostat,4,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building,6,0,1,50,1 +UI800, BC400,thermostat,4,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp,6,0,1,51,1 +UI800, BC400,thermostat,4,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping,6,0,1,52,1 +UI800, BC400,thermostat,4,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy,6,0,1,53,1 +UI800, BC400,thermostat,4,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp,6,0,1,54,1 +UI800, BC400,thermostat,4,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio,6,0,1/10,55,1 +UI800, BC400,thermostat,4,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor,6,0,1/10,56,1 +UI800, BC400,thermostat,4,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor,6,0,1/10,57,1 +UI800, BC400,thermostat,4,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler,6,0,1,58,1 +UI800, BC400,thermostat,4,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler,6,0,1,59,1 +UI800, BC400,thermostat,4,pvenabledhw,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenabledhw,6,0,1,60,1 +UI800, BC400,thermostat,4,pvraiseheat,raise heating with PV,int8 (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat,6,0,1,61,1 +UI800, BC400,thermostat,4,pvlowercool,lower cooling with PV,int8 (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool,6,0,1,62,1 +UI800, BC400,thermostat,4,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp,6,1,1/2,0,1 +UI800, BC400,thermostat,4,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/10,1,1 +UI800, BC400,thermostat,4,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 +UI800, BC400,thermostat,4,mode,operating mode,enum [off\|manual\|auto], ,true,select.thermostat_hc1_operating_mode,select.thermostat_hc1_mode,6,1,1,3,1 +UI800, BC400,thermostat,4,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype,6,1,1,4,1 +UI800, BC400,thermostat,4,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp,6,1,1/2,5,1 +UI800, BC400,thermostat,4,manualtemp,manual temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp,6,1,1/2,6,1 +UI800, BC400,thermostat,4,comforttemp,comfort temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp,6,1,1/2,7,1 +UI800, BC400,thermostat,4,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 +UI800, BC400,thermostat,4,designtemp,design temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp,6,1,1,9,1 +UI800, BC400,thermostat,4,offsettemp,offset temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp,6,1,1,10,1 +UI800, BC400,thermostat,4,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp,6,1,1,11,1 +UI800, BC400,thermostat,4,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp,6,1,1,12,1 +UI800, BC400,thermostat,4,roominfluence,room influence,uint8 (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence,6,1,1,13,1 +UI800, BC400,thermostat,4,roominflfactor,room influence factor,uint8 (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor,6,1,1/10,14,1 +UI800, BC400,thermostat,4,curroominfl,current room influence,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl,6,1,1/10,15,1 +UI800, BC400,thermostat,4,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode,6,1,1,16,1 +UI800, BC400,thermostat,4,nofrosttemp,nofrost temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp,6,1,1,17,1 +UI800, BC400,thermostat,4,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp,6,1,1,18,1 +UI800, BC400,thermostat,4,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype,6,1,1,19,1 +UI800, BC400,thermostat,4,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode,6,1,1,20,1 +UI800, BC400,thermostat,4,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode,6,1,1,21,1 +UI800, BC400,thermostat,4,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode,6,1,1,22,1 +UI800, BC400,thermostat,4,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate,6,1,1,23,1 +UI800, BC400,thermostat,4,controlmode,control mode,enum [weather compensated\|outside basepoint\|n/a\|room\|power\|constant], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode,6,1,1,24,1 +UI800, BC400,thermostat,4,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program,6,1,1,25,1 +UI800, BC400,thermostat,4,tempautotemp,temporary set temperature automode,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp,6,1,1/2,26,1 +UI800, BC400,thermostat,4,remoteseltemp,temporary set temperature from remote,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_from_remote,number.thermostat_hc1_remoteseltemp,6,1,1/2,27,1 +UI800, BC400,thermostat,4,fastheatup,fast heatup,uint8 (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup,6,1,1,28,1 +UI800, BC400,thermostat,4,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization,6,1,1,29,1 +UI800, BC400,thermostat,4,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode,6,1,1,30,1 +UI800, BC400,thermostat,4,noreducetemp,no reduce below temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp,6,1,1,31,1 +UI800, BC400,thermostat,4,reducetemp,off/reduce switch temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp,6,1,1,32,1 +UI800, BC400,thermostat,4,dhwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_dhwprio,6,1,1,33,1 +UI800, BC400,thermostat,4,hpcooling,hp cooling,boolean, ,true,switch.thermostat_hc1_hp_cooling,switch.thermostat_hc1_hpcooling,6,1,1,34,1 +UI800, BC400,thermostat,4,coolingon,cooling on,boolean, ,false,binary_sensor.thermostat_hc1_cooling_on,binary_sensor.thermostat_hc1_coolingon,6,1,1,35,1 +UI800, BC400,thermostat,4,hpmode,HP Mode,enum [heating\|cooling\|heating & cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode,6,1,1,36,1 +UI800, BC400,thermostat,4,dewoffset,dew point offset,uint8 (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset,6,1,1,37,1 +UI800, BC400,thermostat,4,roomtempdiff,room temp difference,uint8 (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff,6,1,1,38,1 +UI800, BC400,thermostat,4,hpminflowtemp,HP min. flow temp.,uint8 (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp,6,1,1,39,1 +UI800, BC400,thermostat,4,control,control device,enum [off\|-\|RC100\|RC100H\|-\|RC120RF\|RC220/RT800\|single], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control,6,1,1,40,1 +UI800, BC400,thermostat,4,remotetemp,room temperature from remote,cmd [] (>=-1<=101),C,true,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp,6,1,1/10,41,1 +UI800, BC400,thermostat,4,remotehum,room humidity from remote,cmd [] (>=-1<=101),%,true,sensor.thermostat_hc1_room_humidity_from_remote,sensor.thermostat_hc1_remotehum,6,1,1,42,1 +UI800, BC400,thermostat,4,heatondelay,heat-on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay,6,1,1,43,1 +UI800, BC400,thermostat,4,heatoffdelay,heat-off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay,6,1,1,44,1 +UI800, BC400,thermostat,4,instantstart,instant start,uint8 (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart,6,1,1,45,1 +UI800, BC400,thermostat,4,boost,boost mode,boolean, ,true,switch.thermostat_hc1_boost_mode,switch.thermostat_hc1_boost,6,1,1,46,1 +UI800, BC400,thermostat,4,boosttime,boost time,uint8 (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime,6,1,1,47,1 +UI800, BC400,thermostat,4,coolstart,cooling starttemp,uint8 (>=20<=35),C,true,number.thermostat_hc1_cooling_starttemp,number.thermostat_hc1_coolstart,6,1,1,193,1 +UI800, BC400,thermostat,4,coolondelay,cooling on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_on_delay,number.thermostat_hc1_coolondelay,6,1,1,194,1 +UI800, BC400,thermostat,4,cooloffdelay,cooling off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_off_delay,number.thermostat_hc1_cooloffdelay,6,1,1,195,1 +UI800, BC400,thermostat,4,switchprogmode,switch program mode,enum [level\|absolute], ,true,select.thermostat_hc1_switch_program_mode,select.thermostat_hc1_switchprogmode,6,1,1,196,1 +UI800, BC400,thermostat,4,mode,operating mode,enum [off\|eco+\|eco\|comfort\|auto], ,true,select.thermostat_dhw_operating_mode,select.thermostat_dhw_mode,6,9,1,0,1 +UI800, BC400,thermostat,4,settemp,set temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_temperature,number.thermostat_dhw_settemp,6,9,1,1,1 +UI800, BC400,thermostat,4,settemplow,set low temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_low_temperature,number.thermostat_dhw_settemplow,6,9,1,2,1 +UI800, BC400,thermostat,4,circmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_dhw_circulation_pump_mode,select.thermostat_dhw_circmode,6,9,1,3,1 +UI800, BC400,thermostat,4,chargeduration,charge duration,uint8 (>=0<=3810),minutes,true,number.thermostat_dhw_charge_duration,number.thermostat_dhw_chargeduration,6,9,15,4,1 +UI800, BC400,thermostat,4,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge,6,9,1,5,1 +UI800, BC400,thermostat,4,extra,extra,uint8 (>=0<=254),C,false,sensor.thermostat_dhw_extra,sensor.thermostat_dhw_extra,6,9,1,6,1 +UI800, BC400,thermostat,4,disinfecting,disinfecting,boolean, ,true,switch.thermostat_dhw_disinfecting,switch.thermostat_dhw_disinfecting,6,9,1,7,1 +UI800, BC400,thermostat,4,disinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_dhw_disinfection_day,select.thermostat_dhw_disinfectday,6,9,1,8,1 +UI800, BC400,thermostat,4,disinfecttime,disinfection time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_disinfection_time,number.thermostat_dhw_disinfecttime,6,9,15,9,1 +UI800, BC400,thermostat,4,dailyheating,daily heating,boolean, ,true,switch.thermostat_dhw_daily_heating,switch.thermostat_dhw_dailyheating,6,9,1,10,1 +UI800, BC400,thermostat,4,dailyheattime,daily heating time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_daily_heating_time,number.thermostat_dhw_dailyheattime,6,9,15,11,1 RC10,thermostat,65,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 RC10,thermostat,65,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 RC10,thermostat,65,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 @@ -3493,20 +3524,20 @@ RC30,thermostat,67,switchtimeWW,program switchtime warm water,string, ,true,sens RC30,thermostat,67,circswitchtime,circulation program switchtime,string, ,true,sensor.thermostat_dhw_circulation_program_switchtime,sensor.thermostat_dhw_circswitchtime,6,9,1,25,8 RC30,thermostat,67,holidays,holiday dates,string, ,true,sensor.thermostat_dhw_holiday_dates,sensor.thermostat_dhw_holidays,6,9,1,33,13 RC30,thermostat,67,vacations,vacation dates,string, ,true,sensor.thermostat_dhw_vacation_dates,sensor.thermostat_dhw_vacations,6,9,1,46,13 -RC20/Moduline 300,thermostat,77,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 -RC20/Moduline 300,thermostat,77,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 -RC20/Moduline 300,thermostat,77,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 -RC20/Moduline 300,thermostat,77,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp,6,1,1/2,0,1 -RC20/Moduline 300,thermostat,77,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/10,1,1 -RC20/Moduline 300,thermostat,77,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 -RC20/Moduline 300,thermostat,77,mode,operating mode,enum [off\|manual\|auto], ,true,select.thermostat_hc1_operating_mode,select.thermostat_hc1_mode,6,1,1,3,1 -RC20/Moduline 300,thermostat,77,manualtemp,manual temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp,6,1,1/2,6,1 -RC20/Moduline 300,thermostat,77,offtemp,temperature when mode is off,uint8 (>=0<=127),C,true,number.thermostat_hc1_temperature_when_mode_is_off,number.thermostat_hc1_offtemp,6,1,1/2,99,1 -RC20/Moduline 300,thermostat,77,daytemp2,day temperature T2,uint8 (>=0<=127),C,true,number.thermostat_hc1_day_temperature_T2,number.thermostat_hc1_daytemp2,6,1,1/2,100,1 -RC20/Moduline 300,thermostat,77,daytemp3,day temperature T3,uint8 (>=0<=127),C,true,number.thermostat_hc1_day_temperature_T3,number.thermostat_hc1_daytemp3,6,1,1/2,101,1 -RC20/Moduline 300,thermostat,77,daytemp4,day temperature T4,uint8 (>=0<=127),C,true,number.thermostat_hc1_day_temperature_T4,number.thermostat_hc1_daytemp4,6,1,1/2,102,1 -RC20/Moduline 300,thermostat,77,nighttemp,night temperature T1,uint8 (>=0<=127),C,true,number.thermostat_hc1_night_temperature_T1,number.thermostat_hc1_nighttemp,6,1,1/2,49,1 -RC20/Moduline 300,thermostat,77,switchtime,program switchtime,string, ,true,sensor.thermostat_hc1_program_switchtime,sensor.thermostat_hc1_switchtime,6,1,1,197,8 +RC20, Moduline 300,thermostat,77,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 +RC20, Moduline 300,thermostat,77,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 +RC20, Moduline 300,thermostat,77,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 +RC20, Moduline 300,thermostat,77,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp,6,1,1/2,0,1 +RC20, Moduline 300,thermostat,77,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/10,1,1 +RC20, Moduline 300,thermostat,77,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 +RC20, Moduline 300,thermostat,77,mode,operating mode,enum [off\|manual\|auto], ,true,select.thermostat_hc1_operating_mode,select.thermostat_hc1_mode,6,1,1,3,1 +RC20, Moduline 300,thermostat,77,manualtemp,manual temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp,6,1,1/2,6,1 +RC20, Moduline 300,thermostat,77,offtemp,temperature when mode is off,uint8 (>=0<=127),C,true,number.thermostat_hc1_temperature_when_mode_is_off,number.thermostat_hc1_offtemp,6,1,1/2,99,1 +RC20, Moduline 300,thermostat,77,daytemp2,day temperature T2,uint8 (>=0<=127),C,true,number.thermostat_hc1_day_temperature_T2,number.thermostat_hc1_daytemp2,6,1,1/2,100,1 +RC20, Moduline 300,thermostat,77,daytemp3,day temperature T3,uint8 (>=0<=127),C,true,number.thermostat_hc1_day_temperature_T3,number.thermostat_hc1_daytemp3,6,1,1/2,101,1 +RC20, Moduline 300,thermostat,77,daytemp4,day temperature T4,uint8 (>=0<=127),C,true,number.thermostat_hc1_day_temperature_T4,number.thermostat_hc1_daytemp4,6,1,1/2,102,1 +RC20, Moduline 300,thermostat,77,nighttemp,night temperature T1,uint8 (>=0<=127),C,true,number.thermostat_hc1_night_temperature_T1,number.thermostat_hc1_nighttemp,6,1,1/2,49,1 +RC20, Moduline 300,thermostat,77,switchtime,program switchtime,string, ,true,sensor.thermostat_hc1_program_switchtime,sensor.thermostat_hc1_switchtime,6,1,1,197,8 Moduline 400,thermostat,78,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 Moduline 400,thermostat,78,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 Moduline 400,thermostat,78,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 @@ -3549,20 +3580,20 @@ Moduline 400,thermostat,78,whenmodeoff,when thermostat mode off,boolean, ,true,s Moduline 400,thermostat,78,disinfecting,disinfecting,boolean, ,true,switch.thermostat_dhw_disinfecting,switch.thermostat_dhw_disinfecting,6,9,1,7,1 Moduline 400,thermostat,78,disinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_dhw_disinfection_day,select.thermostat_dhw_disinfectday,6,9,1,8,1 Moduline 400,thermostat,78,disinfecthour,disinfection hour,uint8 (>=0<=23), ,true,number.thermostat_dhw_disinfection_hour,number.thermostat_dhw_disinfecthour,6,9,1,14,1 -RC10/Moduline 100,thermostat,79,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 -RC10/Moduline 100,thermostat,79,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 -RC10/Moduline 100,thermostat,79,intoffset,internal temperature offset,int8 (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset,6,0,1/10,46,1 -RC10/Moduline 100,thermostat,79,heatingpid,heating PID,enum [fast\|medium\|slow], ,true,select.thermostat_heating_PID,select.thermostat_heatingpid,6,0,1,72,1 -RC10/Moduline 100,thermostat,79,backlight,key backlight,boolean, ,true,switch.thermostat_key_backlight,switch.thermostat_backlight,6,0,1,69,1 -RC10/Moduline 100,thermostat,79,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp,6,1,1/2,0,1 -RC10/Moduline 100,thermostat,79,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/10,1,1 -RC10/Moduline 100,thermostat,79,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 -RC10/Moduline 100,thermostat,79,mode,operating mode,enum [nofrost\|night\|day], ,true,select.thermostat_hc1_operating_mode,select.thermostat_hc1_mode,6,1,1,3,1 -RC10/Moduline 100,thermostat,79,daytemp,day temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp,6,1,1/2,48,1 -RC10/Moduline 100,thermostat,79,nighttemp,night temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp,6,1,1/2,49,1 -RC10/Moduline 100,thermostat,79,reducehours,duration for nighttemp,uint8 (>=0<=254),hours,true,number.thermostat_hc1_duration_for_nighttemp,number.thermostat_hc1_reducehours,6,1,1,188,1 -RC10/Moduline 100,thermostat,79,reduceminutes,remaining time for nightmode,uint16 (>=0<=31999),minutes,false,sensor.thermostat_hc1_remaining_time_for_nightmode,sensor.thermostat_hc1_reduceminutes,6,1,1,189,1 -RC10/Moduline 100,thermostat,79,mode,operating mode,enum [on\|off\|auto], ,true,select.thermostat_dhw_operating_mode,select.thermostat_dhw_mode,6,9,1,0,1 +RC10, Moduline 100,thermostat,79,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 +RC10, Moduline 100,thermostat,79,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 +RC10, Moduline 100,thermostat,79,intoffset,internal temperature offset,int8 (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset,6,0,1/10,46,1 +RC10, Moduline 100,thermostat,79,heatingpid,heating PID,enum [fast\|medium\|slow], ,true,select.thermostat_heating_PID,select.thermostat_heatingpid,6,0,1,72,1 +RC10, Moduline 100,thermostat,79,backlight,key backlight,boolean, ,true,switch.thermostat_key_backlight,switch.thermostat_backlight,6,0,1,69,1 +RC10, Moduline 100,thermostat,79,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp,6,1,1/2,0,1 +RC10, Moduline 100,thermostat,79,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/10,1,1 +RC10, Moduline 100,thermostat,79,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 +RC10, Moduline 100,thermostat,79,mode,operating mode,enum [nofrost\|night\|day], ,true,select.thermostat_hc1_operating_mode,select.thermostat_hc1_mode,6,1,1,3,1 +RC10, Moduline 100,thermostat,79,daytemp,day temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp,6,1,1/2,48,1 +RC10, Moduline 100,thermostat,79,nighttemp,night temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp,6,1,1/2,49,1 +RC10, Moduline 100,thermostat,79,reducehours,duration for nighttemp,uint8 (>=0<=254),hours,true,number.thermostat_hc1_duration_for_nighttemp,number.thermostat_hc1_reducehours,6,1,1,188,1 +RC10, Moduline 100,thermostat,79,reduceminutes,remaining time for nightmode,uint16 (>=0<=31999),minutes,false,sensor.thermostat_hc1_remaining_time_for_nightmode,sensor.thermostat_hc1_reduceminutes,6,1,1,189,1 +RC10, Moduline 100,thermostat,79,mode,operating mode,enum [on\|off\|auto], ,true,select.thermostat_dhw_operating_mode,select.thermostat_dhw_mode,6,9,1,0,1 Moduline 200,thermostat,80,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 Moduline 200,thermostat,80,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 Moduline 200,thermostat,80,intoffset,internal temperature offset,int8 (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset,6,0,1/10,46,1 @@ -3639,24 +3670,24 @@ RC35,thermostat,86,switchtimeWW,program switchtime warm water,string, ,true,sens RC35,thermostat,86,circswitchtime,circulation program switchtime,string, ,true,sensor.thermostat_dhw_circulation_program_switchtime,sensor.thermostat_dhw_circswitchtime,6,9,1,25,8 RC35,thermostat,86,holidays,holiday dates,string, ,true,sensor.thermostat_dhw_holiday_dates,sensor.thermostat_dhw_holidays,6,9,1,33,13 RC35,thermostat,86,vacations,vacation dates,string, ,true,sensor.thermostat_dhw_vacation_dates,sensor.thermostat_dhw_vacations,6,9,1,46,13 -RC10/Moduline 100,thermostat,90,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 -RC10/Moduline 100,thermostat,90,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 -RC10/Moduline 100,thermostat,90,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 -RC10/Moduline 100,thermostat,90,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp,6,0,1,51,1 -RC10/Moduline 100,thermostat,90,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp,6,1,1/2,0,1 -RC10/Moduline 100,thermostat,90,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/10,1,1 -RC10/Moduline 100,thermostat,90,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 -RC10/Moduline 100,thermostat,90,mode,operating mode,enum [night\|day\|auto], ,true,select.thermostat_hc1_operating_mode,select.thermostat_hc1_mode,6,1,1,3,1 -RC10/Moduline 100,thermostat,90,modetype,mode type,enum [night\|day], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype,6,1,1,4,1 -RC10/Moduline 100,thermostat,90,daytemp,day temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp,6,1,1/2,48,1 -RC10/Moduline 100,thermostat,90,nighttemp,night temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp,6,1,1/2,49,1 -RC10/Moduline 100,thermostat,90,program,program,enum [family\|morning\|evening\|am\|pm\|midday\|singles\|seniors], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program,6,1,1,25,1 -RC10/Moduline 100,thermostat,90,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp,6,1,1,11,1 -RC10/Moduline 100,thermostat,90,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp,6,1,1,12,1 -RC10/Moduline 100,thermostat,90,tempautotemp,temporary set temperature automode,uint8 (>=0<=127),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp,6,1,1/2,26,1 -RC10/Moduline 100,thermostat,90,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype,6,1,1,19,1 -RC10/Moduline 100,thermostat,90,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 -RC10/Moduline 100,thermostat,90,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode,6,1,1,22,1 +RC10, Moduline 100,thermostat,90,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 +RC10, Moduline 100,thermostat,90,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 +RC10, Moduline 100,thermostat,90,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 +RC10, Moduline 100,thermostat,90,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp,6,0,1,51,1 +RC10, Moduline 100,thermostat,90,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp,6,1,1/2,0,1 +RC10, Moduline 100,thermostat,90,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/10,1,1 +RC10, Moduline 100,thermostat,90,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 +RC10, Moduline 100,thermostat,90,mode,operating mode,enum [night\|day\|auto], ,true,select.thermostat_hc1_operating_mode,select.thermostat_hc1_mode,6,1,1,3,1 +RC10, Moduline 100,thermostat,90,modetype,mode type,enum [night\|day], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype,6,1,1,4,1 +RC10, Moduline 100,thermostat,90,daytemp,day temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp,6,1,1/2,48,1 +RC10, Moduline 100,thermostat,90,nighttemp,night temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp,6,1,1/2,49,1 +RC10, Moduline 100,thermostat,90,program,program,enum [family\|morning\|evening\|am\|pm\|midday\|singles\|seniors], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program,6,1,1,25,1 +RC10, Moduline 100,thermostat,90,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp,6,1,1,11,1 +RC10, Moduline 100,thermostat,90,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp,6,1,1,12,1 +RC10, Moduline 100,thermostat,90,tempautotemp,temporary set temperature automode,uint8 (>=0<=127),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp,6,1,1/2,26,1 +RC10, Moduline 100,thermostat,90,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype,6,1,1,19,1 +RC10, Moduline 100,thermostat,90,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 +RC10, Moduline 100,thermostat,90,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode,6,1,1,22,1 RC20RF,thermostat,93,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 RC20RF,thermostat,93,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 RC20RF,thermostat,93,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 @@ -3695,258 +3726,258 @@ RC25,thermostat,151,tempautotemp,temporary set temperature automode,uint8 (>=0<= RC25,thermostat,151,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype,6,1,1,19,1 RC25,thermostat,151,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 RC25,thermostat,151,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode,6,1,1,22,1 -RC200/CW100/CR120/CR50,thermostat,157,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 -RC200/CW100/CR120/CR50,thermostat,157,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 -RC200/CW100/CR120/CR50,thermostat,157,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 -RC200/CW100/CR120/CR50,thermostat,157,intoffset,internal temperature offset,int8 (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset,6,0,1/10,46,1 -RC200/CW100/CR120/CR50,thermostat,157,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry,6,0,1,47,1 -RC200/CW100/CR120/CR50,thermostat,157,dampedoutdoortemp,damped outdoor temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp,6,0,1/10,48,1 -RC200/CW100/CR120/CR50,thermostat,157,floordrytemp,floor drying temperature,uint8 (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp,6,0,1,49,1 -RC200/CW100/CR120/CR50,thermostat,157,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building,6,0,1,50,1 -RC200/CW100/CR120/CR50,thermostat,157,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp,6,0,1,51,1 -RC200/CW100/CR120/CR50,thermostat,157,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping,6,0,1,52,1 -RC200/CW100/CR120/CR50,thermostat,157,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy,6,0,1,53,1 -RC200/CW100/CR120/CR50,thermostat,157,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp,6,0,1,54,1 -RC200/CW100/CR120/CR50,thermostat,157,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio,6,0,1/10,55,1 -RC200/CW100/CR120/CR50,thermostat,157,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor,6,0,1/10,56,1 -RC200/CW100/CR120/CR50,thermostat,157,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor,6,0,1/10,57,1 -RC200/CW100/CR120/CR50,thermostat,157,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler,6,0,1,58,1 -RC200/CW100/CR120/CR50,thermostat,157,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler,6,0,1,59,1 -RC200/CW100/CR120/CR50,thermostat,157,pvenabledhw,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenabledhw,6,0,1,60,1 -RC200/CW100/CR120/CR50,thermostat,157,pvraiseheat,raise heating with PV,int8 (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat,6,0,1,61,1 -RC200/CW100/CR120/CR50,thermostat,157,pvlowercool,lower cooling with PV,int8 (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool,6,0,1,62,1 -RC200/CW100/CR120/CR50,thermostat,157,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp,6,1,1/2,0,1 -RC200/CW100/CR120/CR50,thermostat,157,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/10,1,1 -RC200/CW100/CR120/CR50,thermostat,157,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 -RC200/CW100/CR120/CR50,thermostat,157,mode,operating mode,enum [manual\|auto], ,true,select.thermostat_hc1_operating_mode,select.thermostat_hc1_mode,6,1,1,3,1 -RC200/CW100/CR120/CR50,thermostat,157,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype,6,1,1,4,1 -RC200/CW100/CR120/CR50,thermostat,157,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp,6,1,1/2,5,1 -RC200/CW100/CR120/CR50,thermostat,157,manualtemp,manual temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp,6,1,1/2,6,1 -RC200/CW100/CR120/CR50,thermostat,157,comforttemp,comfort temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp,6,1,1/2,7,1 -RC200/CW100/CR120/CR50,thermostat,157,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 -RC200/CW100/CR120/CR50,thermostat,157,designtemp,design temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp,6,1,1,9,1 -RC200/CW100/CR120/CR50,thermostat,157,offsettemp,offset temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp,6,1,1,10,1 -RC200/CW100/CR120/CR50,thermostat,157,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp,6,1,1,11,1 -RC200/CW100/CR120/CR50,thermostat,157,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp,6,1,1,12,1 -RC200/CW100/CR120/CR50,thermostat,157,roominfluence,room influence,uint8 (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence,6,1,1,13,1 -RC200/CW100/CR120/CR50,thermostat,157,roominflfactor,room influence factor,uint8 (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor,6,1,1/10,14,1 -RC200/CW100/CR120/CR50,thermostat,157,curroominfl,current room influence,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl,6,1,1/10,15,1 -RC200/CW100/CR120/CR50,thermostat,157,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode,6,1,1,16,1 -RC200/CW100/CR120/CR50,thermostat,157,nofrosttemp,nofrost temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp,6,1,1,17,1 -RC200/CW100/CR120/CR50,thermostat,157,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp,6,1,1,18,1 -RC200/CW100/CR120/CR50,thermostat,157,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype,6,1,1,19,1 -RC200/CW100/CR120/CR50,thermostat,157,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode,6,1,1,20,1 -RC200/CW100/CR120/CR50,thermostat,157,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode,6,1,1,21,1 -RC200/CW100/CR120/CR50,thermostat,157,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode,6,1,1,22,1 -RC200/CW100/CR120/CR50,thermostat,157,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate,6,1,1,23,1 -RC200/CW100/CR120/CR50,thermostat,157,controlmode,control mode,enum [optimized\|simple\|n/a\|room\|power], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode,6,1,1,24,1 -RC200/CW100/CR120/CR50,thermostat,157,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program,6,1,1,25,1 -RC200/CW100/CR120/CR50,thermostat,157,tempautotemp,temporary set temperature automode,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp,6,1,1/2,26,1 -RC200/CW100/CR120/CR50,thermostat,157,remoteseltemp,temporary set temperature from remote,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_from_remote,number.thermostat_hc1_remoteseltemp,6,1,1/2,27,1 -RC200/CW100/CR120/CR50,thermostat,157,fastheatup,fast heatup,uint8 (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup,6,1,1,28,1 -RC200/CW100/CR120/CR50,thermostat,157,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization,6,1,1,29,1 -RC200/CW100/CR120/CR50,thermostat,157,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode,6,1,1,30,1 -RC200/CW100/CR120/CR50,thermostat,157,noreducetemp,no reduce below temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp,6,1,1,31,1 -RC200/CW100/CR120/CR50,thermostat,157,reducetemp,off/reduce switch temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp,6,1,1,32,1 -RC200/CW100/CR120/CR50,thermostat,157,dhwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_dhwprio,6,1,1,33,1 -RC200/CW100/CR120/CR50,thermostat,157,hpcooling,hp cooling,boolean, ,true,switch.thermostat_hc1_hp_cooling,switch.thermostat_hc1_hpcooling,6,1,1,34,1 -RC200/CW100/CR120/CR50,thermostat,157,coolingon,cooling on,boolean, ,false,binary_sensor.thermostat_hc1_cooling_on,binary_sensor.thermostat_hc1_coolingon,6,1,1,35,1 -RC200/CW100/CR120/CR50,thermostat,157,hpmode,HP Mode,enum [heating\|cooling\|heating & cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode,6,1,1,36,1 -RC200/CW100/CR120/CR50,thermostat,157,dewoffset,dew point offset,uint8 (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset,6,1,1,37,1 -RC200/CW100/CR120/CR50,thermostat,157,roomtempdiff,room temp difference,uint8 (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff,6,1,1,38,1 -RC200/CW100/CR120/CR50,thermostat,157,hpminflowtemp,HP min. flow temp.,uint8 (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp,6,1,1,39,1 -RC200/CW100/CR120/CR50,thermostat,157,control,control device,enum [RC310\|RC200\|RC100\|RC100H\|TC100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control,6,1,1,40,1 -RC200/CW100/CR120/CR50,thermostat,157,remotetemp,room temperature from remote,cmd [] (>=-1<=101),C,true,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp,6,1,1/10,41,1 -RC200/CW100/CR120/CR50,thermostat,157,remotehum,room humidity from remote,cmd [] (>=-1<=101),%,true,sensor.thermostat_hc1_room_humidity_from_remote,sensor.thermostat_hc1_remotehum,6,1,1,42,1 -RC200/CW100/CR120/CR50,thermostat,157,heatondelay,heat-on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay,6,1,1,43,1 -RC200/CW100/CR120/CR50,thermostat,157,heatoffdelay,heat-off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay,6,1,1,44,1 -RC200/CW100/CR120/CR50,thermostat,157,instantstart,instant start,uint8 (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart,6,1,1,45,1 -RC200/CW100/CR120/CR50,thermostat,157,boost,boost mode,boolean, ,true,switch.thermostat_hc1_boost_mode,switch.thermostat_hc1_boost,6,1,1,46,1 -RC200/CW100/CR120/CR50,thermostat,157,boosttime,boost time,uint8 (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime,6,1,1,47,1 -RC200/CW100/CR120/CR50,thermostat,157,coolstart,cooling starttemp,uint8 (>=20<=35),C,true,number.thermostat_hc1_cooling_starttemp,number.thermostat_hc1_coolstart,6,1,1,193,1 -RC200/CW100/CR120/CR50,thermostat,157,coolondelay,cooling on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_on_delay,number.thermostat_hc1_coolondelay,6,1,1,194,1 -RC200/CW100/CR120/CR50,thermostat,157,cooloffdelay,cooling off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_off_delay,number.thermostat_hc1_cooloffdelay,6,1,1,195,1 -RC200/CW100/CR120/CR50,thermostat,157,switchprogmode,switch program mode,enum [level\|absolute], ,true,select.thermostat_hc1_switch_program_mode,select.thermostat_hc1_switchprogmode,6,1,1,196,1 -RC200/CW100/CR120/CR50,thermostat,157,mode,operating mode,enum [off\|normal\|comfort\|auto\|own prog], ,true,select.thermostat_dhw_operating_mode,select.thermostat_dhw_mode,6,9,1,0,1 -RC200/CW100/CR120/CR50,thermostat,157,settemp,set temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_temperature,number.thermostat_dhw_settemp,6,9,1,1,1 -RC200/CW100/CR120/CR50,thermostat,157,settemplow,set low temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_low_temperature,number.thermostat_dhw_settemplow,6,9,1,2,1 -RC200/CW100/CR120/CR50,thermostat,157,circmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_dhw_circulation_pump_mode,select.thermostat_dhw_circmode,6,9,1,3,1 -RC200/CW100/CR120/CR50,thermostat,157,chargeduration,charge duration,uint8 (>=0<=3810),minutes,true,number.thermostat_dhw_charge_duration,number.thermostat_dhw_chargeduration,6,9,15,4,1 -RC200/CW100/CR120/CR50,thermostat,157,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge,6,9,1,5,1 -RC200/CW100/CR120/CR50,thermostat,157,extra,extra,uint8 (>=0<=254),C,false,sensor.thermostat_dhw_extra,sensor.thermostat_dhw_extra,6,9,1,6,1 -RC200/CW100/CR120/CR50,thermostat,157,disinfecting,disinfecting,boolean, ,true,switch.thermostat_dhw_disinfecting,switch.thermostat_dhw_disinfecting,6,9,1,7,1 -RC200/CW100/CR120/CR50,thermostat,157,disinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_dhw_disinfection_day,select.thermostat_dhw_disinfectday,6,9,1,8,1 -RC200/CW100/CR120/CR50,thermostat,157,disinfecttime,disinfection time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_disinfection_time,number.thermostat_dhw_disinfecttime,6,9,15,9,1 -RC200/CW100/CR120/CR50,thermostat,157,dailyheating,daily heating,boolean, ,true,switch.thermostat_dhw_daily_heating,switch.thermostat_dhw_dailyheating,6,9,1,10,1 -RC200/CW100/CR120/CR50,thermostat,157,dailyheattime,daily heating time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_daily_heating_time,number.thermostat_dhw_dailyheattime,6,9,15,11,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,intoffset,internal temperature offset,int8 (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset,6,0,1/10,46,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry,6,0,1,47,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,dampedoutdoortemp,damped outdoor temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp,6,0,1/10,48,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,floordrytemp,floor drying temperature,uint8 (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp,6,0,1,49,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building,6,0,1,50,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp,6,0,1,51,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping,6,0,1,52,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy,6,0,1,53,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp,6,0,1,54,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio,6,0,1/10,55,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor,6,0,1/10,56,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor,6,0,1/10,57,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler,6,0,1,58,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler,6,0,1,59,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,pvenabledhw,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenabledhw,6,0,1,60,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,pvraiseheat,raise heating with PV,int8 (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat,6,0,1,61,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,pvlowercool,lower cooling with PV,int8 (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool,6,0,1,62,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp,6,1,1/2,0,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/10,1,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,mode,operating mode,enum [manual\|auto], ,true,select.thermostat_hc1_operating_mode,select.thermostat_hc1_mode,6,1,1,3,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype,6,1,1,4,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp,6,1,1/2,5,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,manualtemp,manual temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp,6,1,1/2,6,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,comforttemp,comfort temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp,6,1,1/2,7,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,designtemp,design temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp,6,1,1,9,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,offsettemp,offset temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp,6,1,1,10,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp,6,1,1,11,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp,6,1,1,12,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,roominfluence,room influence,uint8 (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence,6,1,1,13,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,roominflfactor,room influence factor,uint8 (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor,6,1,1/10,14,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,curroominfl,current room influence,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl,6,1,1/10,15,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode,6,1,1,16,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,nofrosttemp,nofrost temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp,6,1,1,17,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp,6,1,1,18,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype,6,1,1,19,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode,6,1,1,20,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode,6,1,1,21,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode,6,1,1,22,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate,6,1,1,23,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,controlmode,control mode,enum [weather compensated\|outside basepoint\|n/a\|room\|power\|constant], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode,6,1,1,24,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program,6,1,1,25,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,tempautotemp,temporary set temperature automode,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp,6,1,1/2,26,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,remoteseltemp,temporary set temperature from remote,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_from_remote,number.thermostat_hc1_remoteseltemp,6,1,1/2,27,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,fastheatup,fast heatup,uint8 (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup,6,1,1,28,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization,6,1,1,29,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode,6,1,1,30,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,noreducetemp,no reduce below temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp,6,1,1,31,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,reducetemp,off/reduce switch temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp,6,1,1,32,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,dhwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_dhwprio,6,1,1,33,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,hpcooling,hp cooling,boolean, ,true,switch.thermostat_hc1_hp_cooling,switch.thermostat_hc1_hpcooling,6,1,1,34,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,coolingon,cooling on,boolean, ,false,binary_sensor.thermostat_hc1_cooling_on,binary_sensor.thermostat_hc1_coolingon,6,1,1,35,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,hpmode,HP Mode,enum [heating\|cooling\|heating & cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode,6,1,1,36,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,dewoffset,dew point offset,uint8 (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset,6,1,1,37,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,roomtempdiff,room temp difference,uint8 (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff,6,1,1,38,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,hpminflowtemp,HP min. flow temp.,uint8 (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp,6,1,1,39,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,control,control device,enum [RC310\|RC200\|RC100\|RC100H\|TC100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control,6,1,1,40,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,remotetemp,room temperature from remote,cmd [] (>=-1<=101),C,true,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp,6,1,1/10,41,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,remotehum,room humidity from remote,cmd [] (>=-1<=101),%,true,sensor.thermostat_hc1_room_humidity_from_remote,sensor.thermostat_hc1_remotehum,6,1,1,42,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,heatondelay,heat-on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay,6,1,1,43,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,heatoffdelay,heat-off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay,6,1,1,44,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,instantstart,instant start,uint8 (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart,6,1,1,45,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,boost,boost mode,boolean, ,true,switch.thermostat_hc1_boost_mode,switch.thermostat_hc1_boost,6,1,1,46,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,boosttime,boost time,uint8 (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime,6,1,1,47,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,coolstart,cooling starttemp,uint8 (>=20<=35),C,true,number.thermostat_hc1_cooling_starttemp,number.thermostat_hc1_coolstart,6,1,1,193,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,coolondelay,cooling on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_on_delay,number.thermostat_hc1_coolondelay,6,1,1,194,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,cooloffdelay,cooling off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_off_delay,number.thermostat_hc1_cooloffdelay,6,1,1,195,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,switchprogmode,switch program mode,enum [level\|absolute], ,true,select.thermostat_hc1_switch_program_mode,select.thermostat_hc1_switchprogmode,6,1,1,196,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,mode,operating mode,enum [off\|normal\|comfort\|auto\|own prog], ,true,select.thermostat_dhw_operating_mode,select.thermostat_dhw_mode,6,9,1,0,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,settemp,set temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_temperature,number.thermostat_dhw_settemp,6,9,1,1,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,settemplow,set low temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_low_temperature,number.thermostat_dhw_settemplow,6,9,1,2,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,circmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_dhw_circulation_pump_mode,select.thermostat_dhw_circmode,6,9,1,3,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,chargeduration,charge duration,uint8 (>=0<=3810),minutes,true,number.thermostat_dhw_charge_duration,number.thermostat_dhw_chargeduration,6,9,15,4,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge,6,9,1,5,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,extra,extra,uint8 (>=0<=254),C,false,sensor.thermostat_dhw_extra,sensor.thermostat_dhw_extra,6,9,1,6,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,disinfecting,disinfecting,boolean, ,true,switch.thermostat_dhw_disinfecting,switch.thermostat_dhw_disinfecting,6,9,1,7,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,disinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_dhw_disinfection_day,select.thermostat_dhw_disinfectday,6,9,1,8,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,disinfecttime,disinfection time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_disinfection_time,number.thermostat_dhw_disinfecttime,6,9,15,9,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,dailyheating,daily heating,boolean, ,true,switch.thermostat_dhw_daily_heating,switch.thermostat_dhw_dailyheating,6,9,1,10,1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,dailyheattime,daily heating time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_daily_heating_time,number.thermostat_dhw_dailyheattime,6,9,15,11,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 -RC100/CR10/Moduline 1000/1010,thermostat,165,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 -RC100/CR10/Moduline 1000/1010,thermostat,165,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 -RC100/CR10/Moduline 1000/1010,thermostat,165,intoffset,internal temperature offset,int8 (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset,6,0,1/10,46,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry,6,0,1,47,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,dampedoutdoortemp,damped outdoor temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp,6,0,1/10,48,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,floordrytemp,floor drying temperature,uint8 (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp,6,0,1,49,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building,6,0,1,50,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp,6,0,1,51,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping,6,0,1,52,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy,6,0,1,53,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp,6,0,1,54,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio,6,0,1/10,55,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor,6,0,1/10,56,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor,6,0,1/10,57,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler,6,0,1,58,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler,6,0,1,59,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,pvenabledhw,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenabledhw,6,0,1,60,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,pvraiseheat,raise heating with PV,int8 (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat,6,0,1,61,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,pvlowercool,lower cooling with PV,int8 (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool,6,0,1,62,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp,6,1,1/2,0,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/10,1,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,mode,operating mode,enum [manual\|auto], ,true,select.thermostat_hc1_operating_mode,select.thermostat_hc1_mode,6,1,1,3,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype,6,1,1,4,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp,6,1,1/2,5,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,manualtemp,manual temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp,6,1,1/2,6,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,comforttemp,comfort temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp,6,1,1/2,7,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,designtemp,design temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp,6,1,1,9,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,offsettemp,offset temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp,6,1,1,10,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp,6,1,1,11,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp,6,1,1,12,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,roominfluence,room influence,uint8 (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence,6,1,1,13,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,roominflfactor,room influence factor,uint8 (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor,6,1,1/10,14,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,curroominfl,current room influence,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl,6,1,1/10,15,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode,6,1,1,16,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,nofrosttemp,nofrost temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp,6,1,1,17,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp,6,1,1,18,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype,6,1,1,19,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode,6,1,1,20,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode,6,1,1,21,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode,6,1,1,22,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate,6,1,1,23,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,controlmode,control mode,enum [optimized\|simple\|n/a\|room\|power], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode,6,1,1,24,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program,6,1,1,25,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,tempautotemp,temporary set temperature automode,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp,6,1,1/2,26,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,remoteseltemp,temporary set temperature from remote,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_from_remote,number.thermostat_hc1_remoteseltemp,6,1,1/2,27,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,fastheatup,fast heatup,uint8 (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup,6,1,1,28,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization,6,1,1,29,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode,6,1,1,30,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,noreducetemp,no reduce below temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp,6,1,1,31,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,reducetemp,off/reduce switch temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp,6,1,1,32,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,dhwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_dhwprio,6,1,1,33,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,hpcooling,hp cooling,boolean, ,true,switch.thermostat_hc1_hp_cooling,switch.thermostat_hc1_hpcooling,6,1,1,34,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,coolingon,cooling on,boolean, ,false,binary_sensor.thermostat_hc1_cooling_on,binary_sensor.thermostat_hc1_coolingon,6,1,1,35,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,hpmode,HP Mode,enum [heating\|cooling\|heating & cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode,6,1,1,36,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,dewoffset,dew point offset,uint8 (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset,6,1,1,37,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,roomtempdiff,room temp difference,uint8 (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff,6,1,1,38,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,hpminflowtemp,HP min. flow temp.,uint8 (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp,6,1,1,39,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,control,control device,enum [RC310\|RC200\|RC100\|RC100H\|TC100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control,6,1,1,40,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,remotetemp,room temperature from remote,cmd [] (>=-1<=101),C,true,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp,6,1,1/10,41,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,remotehum,room humidity from remote,cmd [] (>=-1<=101),%,true,sensor.thermostat_hc1_room_humidity_from_remote,sensor.thermostat_hc1_remotehum,6,1,1,42,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,heatondelay,heat-on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay,6,1,1,43,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,heatoffdelay,heat-off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay,6,1,1,44,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,instantstart,instant start,uint8 (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart,6,1,1,45,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,boost,boost mode,boolean, ,true,switch.thermostat_hc1_boost_mode,switch.thermostat_hc1_boost,6,1,1,46,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,boosttime,boost time,uint8 (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime,6,1,1,47,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,coolstart,cooling starttemp,uint8 (>=20<=35),C,true,number.thermostat_hc1_cooling_starttemp,number.thermostat_hc1_coolstart,6,1,1,193,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,coolondelay,cooling on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_on_delay,number.thermostat_hc1_coolondelay,6,1,1,194,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,cooloffdelay,cooling off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_off_delay,number.thermostat_hc1_cooloffdelay,6,1,1,195,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,switchprogmode,switch program mode,enum [level\|absolute], ,true,select.thermostat_hc1_switch_program_mode,select.thermostat_hc1_switchprogmode,6,1,1,196,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,mode,operating mode,enum [off\|normal\|comfort\|auto\|own prog], ,true,select.thermostat_dhw_operating_mode,select.thermostat_dhw_mode,6,9,1,0,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,settemp,set temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_temperature,number.thermostat_dhw_settemp,6,9,1,1,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,settemplow,set low temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_low_temperature,number.thermostat_dhw_settemplow,6,9,1,2,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,circmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_dhw_circulation_pump_mode,select.thermostat_dhw_circmode,6,9,1,3,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,chargeduration,charge duration,uint8 (>=0<=3810),minutes,true,number.thermostat_dhw_charge_duration,number.thermostat_dhw_chargeduration,6,9,15,4,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge,6,9,1,5,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,extra,extra,uint8 (>=0<=254),C,false,sensor.thermostat_dhw_extra,sensor.thermostat_dhw_extra,6,9,1,6,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,disinfecting,disinfecting,boolean, ,true,switch.thermostat_dhw_disinfecting,switch.thermostat_dhw_disinfecting,6,9,1,7,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,disinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_dhw_disinfection_day,select.thermostat_dhw_disinfectday,6,9,1,8,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,disinfecttime,disinfection time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_disinfection_time,number.thermostat_dhw_disinfecttime,6,9,15,9,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,dailyheating,daily heating,boolean, ,true,switch.thermostat_dhw_daily_heating,switch.thermostat_dhw_dailyheating,6,9,1,10,1 -RC100/CR10/Moduline 1000/1010,thermostat,165,dailyheattime,daily heating time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_daily_heating_time,number.thermostat_dhw_dailyheattime,6,9,15,11,1 +RC200, CW100, CR120, CR50,thermostat,157,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 +RC200, CW100, CR120, CR50,thermostat,157,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 +RC200, CW100, CR120, CR50,thermostat,157,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 +RC200, CW100, CR120, CR50,thermostat,157,intoffset,internal temperature offset,int8 (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset,6,0,1/10,46,1 +RC200, CW100, CR120, CR50,thermostat,157,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry,6,0,1,47,1 +RC200, CW100, CR120, CR50,thermostat,157,dampedoutdoortemp,damped outdoor temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp,6,0,1/10,48,1 +RC200, CW100, CR120, CR50,thermostat,157,floordrytemp,floor drying temperature,uint8 (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp,6,0,1,49,1 +RC200, CW100, CR120, CR50,thermostat,157,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building,6,0,1,50,1 +RC200, CW100, CR120, CR50,thermostat,157,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp,6,0,1,51,1 +RC200, CW100, CR120, CR50,thermostat,157,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping,6,0,1,52,1 +RC200, CW100, CR120, CR50,thermostat,157,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy,6,0,1,53,1 +RC200, CW100, CR120, CR50,thermostat,157,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp,6,0,1,54,1 +RC200, CW100, CR120, CR50,thermostat,157,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio,6,0,1/10,55,1 +RC200, CW100, CR120, CR50,thermostat,157,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor,6,0,1/10,56,1 +RC200, CW100, CR120, CR50,thermostat,157,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor,6,0,1/10,57,1 +RC200, CW100, CR120, CR50,thermostat,157,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler,6,0,1,58,1 +RC200, CW100, CR120, CR50,thermostat,157,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler,6,0,1,59,1 +RC200, CW100, CR120, CR50,thermostat,157,pvenabledhw,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenabledhw,6,0,1,60,1 +RC200, CW100, CR120, CR50,thermostat,157,pvraiseheat,raise heating with PV,int8 (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat,6,0,1,61,1 +RC200, CW100, CR120, CR50,thermostat,157,pvlowercool,lower cooling with PV,int8 (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool,6,0,1,62,1 +RC200, CW100, CR120, CR50,thermostat,157,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp,6,1,1/2,0,1 +RC200, CW100, CR120, CR50,thermostat,157,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/10,1,1 +RC200, CW100, CR120, CR50,thermostat,157,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 +RC200, CW100, CR120, CR50,thermostat,157,mode,operating mode,enum [manual\|auto], ,true,select.thermostat_hc1_operating_mode,select.thermostat_hc1_mode,6,1,1,3,1 +RC200, CW100, CR120, CR50,thermostat,157,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype,6,1,1,4,1 +RC200, CW100, CR120, CR50,thermostat,157,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp,6,1,1/2,5,1 +RC200, CW100, CR120, CR50,thermostat,157,manualtemp,manual temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp,6,1,1/2,6,1 +RC200, CW100, CR120, CR50,thermostat,157,comforttemp,comfort temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp,6,1,1/2,7,1 +RC200, CW100, CR120, CR50,thermostat,157,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 +RC200, CW100, CR120, CR50,thermostat,157,designtemp,design temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp,6,1,1,9,1 +RC200, CW100, CR120, CR50,thermostat,157,offsettemp,offset temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp,6,1,1,10,1 +RC200, CW100, CR120, CR50,thermostat,157,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp,6,1,1,11,1 +RC200, CW100, CR120, CR50,thermostat,157,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp,6,1,1,12,1 +RC200, CW100, CR120, CR50,thermostat,157,roominfluence,room influence,uint8 (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence,6,1,1,13,1 +RC200, CW100, CR120, CR50,thermostat,157,roominflfactor,room influence factor,uint8 (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor,6,1,1/10,14,1 +RC200, CW100, CR120, CR50,thermostat,157,curroominfl,current room influence,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl,6,1,1/10,15,1 +RC200, CW100, CR120, CR50,thermostat,157,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode,6,1,1,16,1 +RC200, CW100, CR120, CR50,thermostat,157,nofrosttemp,nofrost temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp,6,1,1,17,1 +RC200, CW100, CR120, CR50,thermostat,157,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp,6,1,1,18,1 +RC200, CW100, CR120, CR50,thermostat,157,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype,6,1,1,19,1 +RC200, CW100, CR120, CR50,thermostat,157,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode,6,1,1,20,1 +RC200, CW100, CR120, CR50,thermostat,157,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode,6,1,1,21,1 +RC200, CW100, CR120, CR50,thermostat,157,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode,6,1,1,22,1 +RC200, CW100, CR120, CR50,thermostat,157,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate,6,1,1,23,1 +RC200, CW100, CR120, CR50,thermostat,157,controlmode,control mode,enum [optimized\|simple\|n/a\|room\|power], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode,6,1,1,24,1 +RC200, CW100, CR120, CR50,thermostat,157,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program,6,1,1,25,1 +RC200, CW100, CR120, CR50,thermostat,157,tempautotemp,temporary set temperature automode,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp,6,1,1/2,26,1 +RC200, CW100, CR120, CR50,thermostat,157,remoteseltemp,temporary set temperature from remote,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_from_remote,number.thermostat_hc1_remoteseltemp,6,1,1/2,27,1 +RC200, CW100, CR120, CR50,thermostat,157,fastheatup,fast heatup,uint8 (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup,6,1,1,28,1 +RC200, CW100, CR120, CR50,thermostat,157,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization,6,1,1,29,1 +RC200, CW100, CR120, CR50,thermostat,157,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode,6,1,1,30,1 +RC200, CW100, CR120, CR50,thermostat,157,noreducetemp,no reduce below temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp,6,1,1,31,1 +RC200, CW100, CR120, CR50,thermostat,157,reducetemp,off/reduce switch temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp,6,1,1,32,1 +RC200, CW100, CR120, CR50,thermostat,157,dhwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_dhwprio,6,1,1,33,1 +RC200, CW100, CR120, CR50,thermostat,157,hpcooling,hp cooling,boolean, ,true,switch.thermostat_hc1_hp_cooling,switch.thermostat_hc1_hpcooling,6,1,1,34,1 +RC200, CW100, CR120, CR50,thermostat,157,coolingon,cooling on,boolean, ,false,binary_sensor.thermostat_hc1_cooling_on,binary_sensor.thermostat_hc1_coolingon,6,1,1,35,1 +RC200, CW100, CR120, CR50,thermostat,157,hpmode,HP Mode,enum [heating\|cooling\|heating & cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode,6,1,1,36,1 +RC200, CW100, CR120, CR50,thermostat,157,dewoffset,dew point offset,uint8 (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset,6,1,1,37,1 +RC200, CW100, CR120, CR50,thermostat,157,roomtempdiff,room temp difference,uint8 (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff,6,1,1,38,1 +RC200, CW100, CR120, CR50,thermostat,157,hpminflowtemp,HP min. flow temp.,uint8 (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp,6,1,1,39,1 +RC200, CW100, CR120, CR50,thermostat,157,control,control device,enum [RC310\|RC200\|RC100\|RC100H\|TC100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control,6,1,1,40,1 +RC200, CW100, CR120, CR50,thermostat,157,remotetemp,room temperature from remote,cmd [] (>=-1<=101),C,true,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp,6,1,1/10,41,1 +RC200, CW100, CR120, CR50,thermostat,157,remotehum,room humidity from remote,cmd [] (>=-1<=101),%,true,sensor.thermostat_hc1_room_humidity_from_remote,sensor.thermostat_hc1_remotehum,6,1,1,42,1 +RC200, CW100, CR120, CR50,thermostat,157,heatondelay,heat-on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay,6,1,1,43,1 +RC200, CW100, CR120, CR50,thermostat,157,heatoffdelay,heat-off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay,6,1,1,44,1 +RC200, CW100, CR120, CR50,thermostat,157,instantstart,instant start,uint8 (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart,6,1,1,45,1 +RC200, CW100, CR120, CR50,thermostat,157,boost,boost mode,boolean, ,true,switch.thermostat_hc1_boost_mode,switch.thermostat_hc1_boost,6,1,1,46,1 +RC200, CW100, CR120, CR50,thermostat,157,boosttime,boost time,uint8 (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime,6,1,1,47,1 +RC200, CW100, CR120, CR50,thermostat,157,coolstart,cooling starttemp,uint8 (>=20<=35),C,true,number.thermostat_hc1_cooling_starttemp,number.thermostat_hc1_coolstart,6,1,1,193,1 +RC200, CW100, CR120, CR50,thermostat,157,coolondelay,cooling on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_on_delay,number.thermostat_hc1_coolondelay,6,1,1,194,1 +RC200, CW100, CR120, CR50,thermostat,157,cooloffdelay,cooling off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_off_delay,number.thermostat_hc1_cooloffdelay,6,1,1,195,1 +RC200, CW100, CR120, CR50,thermostat,157,switchprogmode,switch program mode,enum [level\|absolute], ,true,select.thermostat_hc1_switch_program_mode,select.thermostat_hc1_switchprogmode,6,1,1,196,1 +RC200, CW100, CR120, CR50,thermostat,157,mode,operating mode,enum [off\|normal\|comfort\|auto\|own prog], ,true,select.thermostat_dhw_operating_mode,select.thermostat_dhw_mode,6,9,1,0,1 +RC200, CW100, CR120, CR50,thermostat,157,settemp,set temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_temperature,number.thermostat_dhw_settemp,6,9,1,1,1 +RC200, CW100, CR120, CR50,thermostat,157,settemplow,set low temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_low_temperature,number.thermostat_dhw_settemplow,6,9,1,2,1 +RC200, CW100, CR120, CR50,thermostat,157,circmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_dhw_circulation_pump_mode,select.thermostat_dhw_circmode,6,9,1,3,1 +RC200, CW100, CR120, CR50,thermostat,157,chargeduration,charge duration,uint8 (>=0<=3810),minutes,true,number.thermostat_dhw_charge_duration,number.thermostat_dhw_chargeduration,6,9,15,4,1 +RC200, CW100, CR120, CR50,thermostat,157,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge,6,9,1,5,1 +RC200, CW100, CR120, CR50,thermostat,157,extra,extra,uint8 (>=0<=254),C,false,sensor.thermostat_dhw_extra,sensor.thermostat_dhw_extra,6,9,1,6,1 +RC200, CW100, CR120, CR50,thermostat,157,disinfecting,disinfecting,boolean, ,true,switch.thermostat_dhw_disinfecting,switch.thermostat_dhw_disinfecting,6,9,1,7,1 +RC200, CW100, CR120, CR50,thermostat,157,disinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_dhw_disinfection_day,select.thermostat_dhw_disinfectday,6,9,1,8,1 +RC200, CW100, CR120, CR50,thermostat,157,disinfecttime,disinfection time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_disinfection_time,number.thermostat_dhw_disinfecttime,6,9,15,9,1 +RC200, CW100, CR120, CR50,thermostat,157,dailyheating,daily heating,boolean, ,true,switch.thermostat_dhw_daily_heating,switch.thermostat_dhw_dailyheating,6,9,1,10,1 +RC200, CW100, CR120, CR50,thermostat,157,dailyheattime,daily heating time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_daily_heating_time,number.thermostat_dhw_dailyheattime,6,9,15,11,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,intoffset,internal temperature offset,int8 (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset,6,0,1/10,46,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry,6,0,1,47,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,dampedoutdoortemp,damped outdoor temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp,6,0,1/10,48,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,floordrytemp,floor drying temperature,uint8 (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp,6,0,1,49,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building,6,0,1,50,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp,6,0,1,51,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping,6,0,1,52,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy,6,0,1,53,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp,6,0,1,54,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio,6,0,1/10,55,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor,6,0,1/10,56,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor,6,0,1/10,57,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler,6,0,1,58,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler,6,0,1,59,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,pvenabledhw,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenabledhw,6,0,1,60,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,pvraiseheat,raise heating with PV,int8 (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat,6,0,1,61,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,pvlowercool,lower cooling with PV,int8 (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool,6,0,1,62,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp,6,1,1/2,0,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/10,1,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,mode,operating mode,enum [manual\|auto], ,true,select.thermostat_hc1_operating_mode,select.thermostat_hc1_mode,6,1,1,3,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype,6,1,1,4,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp,6,1,1/2,5,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,manualtemp,manual temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp,6,1,1/2,6,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,comforttemp,comfort temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp,6,1,1/2,7,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,designtemp,design temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp,6,1,1,9,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,offsettemp,offset temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp,6,1,1,10,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp,6,1,1,11,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp,6,1,1,12,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,roominfluence,room influence,uint8 (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence,6,1,1,13,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,roominflfactor,room influence factor,uint8 (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor,6,1,1/10,14,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,curroominfl,current room influence,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl,6,1,1/10,15,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode,6,1,1,16,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,nofrosttemp,nofrost temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp,6,1,1,17,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp,6,1,1,18,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype,6,1,1,19,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode,6,1,1,20,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode,6,1,1,21,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode,6,1,1,22,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate,6,1,1,23,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,controlmode,control mode,enum [weather compensated\|outside basepoint\|n/a\|room\|power\|constant], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode,6,1,1,24,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program,6,1,1,25,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,tempautotemp,temporary set temperature automode,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp,6,1,1/2,26,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,remoteseltemp,temporary set temperature from remote,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_from_remote,number.thermostat_hc1_remoteseltemp,6,1,1/2,27,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,fastheatup,fast heatup,uint8 (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup,6,1,1,28,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization,6,1,1,29,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode,6,1,1,30,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,noreducetemp,no reduce below temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp,6,1,1,31,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,reducetemp,off/reduce switch temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp,6,1,1,32,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,dhwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_dhwprio,6,1,1,33,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,hpcooling,hp cooling,boolean, ,true,switch.thermostat_hc1_hp_cooling,switch.thermostat_hc1_hpcooling,6,1,1,34,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,coolingon,cooling on,boolean, ,false,binary_sensor.thermostat_hc1_cooling_on,binary_sensor.thermostat_hc1_coolingon,6,1,1,35,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,hpmode,HP Mode,enum [heating\|cooling\|heating & cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode,6,1,1,36,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,dewoffset,dew point offset,uint8 (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset,6,1,1,37,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,roomtempdiff,room temp difference,uint8 (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff,6,1,1,38,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,hpminflowtemp,HP min. flow temp.,uint8 (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp,6,1,1,39,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,control,control device,enum [RC310\|RC200\|RC100\|RC100H\|TC100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control,6,1,1,40,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,remotetemp,room temperature from remote,cmd [] (>=-1<=101),C,true,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp,6,1,1/10,41,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,remotehum,room humidity from remote,cmd [] (>=-1<=101),%,true,sensor.thermostat_hc1_room_humidity_from_remote,sensor.thermostat_hc1_remotehum,6,1,1,42,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,heatondelay,heat-on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay,6,1,1,43,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,heatoffdelay,heat-off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay,6,1,1,44,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,instantstart,instant start,uint8 (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart,6,1,1,45,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,boost,boost mode,boolean, ,true,switch.thermostat_hc1_boost_mode,switch.thermostat_hc1_boost,6,1,1,46,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,boosttime,boost time,uint8 (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime,6,1,1,47,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,coolstart,cooling starttemp,uint8 (>=20<=35),C,true,number.thermostat_hc1_cooling_starttemp,number.thermostat_hc1_coolstart,6,1,1,193,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,coolondelay,cooling on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_on_delay,number.thermostat_hc1_coolondelay,6,1,1,194,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,cooloffdelay,cooling off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_off_delay,number.thermostat_hc1_cooloffdelay,6,1,1,195,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,switchprogmode,switch program mode,enum [level\|absolute], ,true,select.thermostat_hc1_switch_program_mode,select.thermostat_hc1_switchprogmode,6,1,1,196,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,mode,operating mode,enum [off\|normal\|comfort\|auto\|own prog], ,true,select.thermostat_dhw_operating_mode,select.thermostat_dhw_mode,6,9,1,0,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,settemp,set temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_temperature,number.thermostat_dhw_settemp,6,9,1,1,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,settemplow,set low temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_low_temperature,number.thermostat_dhw_settemplow,6,9,1,2,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,circmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_dhw_circulation_pump_mode,select.thermostat_dhw_circmode,6,9,1,3,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,chargeduration,charge duration,uint8 (>=0<=3810),minutes,true,number.thermostat_dhw_charge_duration,number.thermostat_dhw_chargeduration,6,9,15,4,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge,6,9,1,5,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,extra,extra,uint8 (>=0<=254),C,false,sensor.thermostat_dhw_extra,sensor.thermostat_dhw_extra,6,9,1,6,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,disinfecting,disinfecting,boolean, ,true,switch.thermostat_dhw_disinfecting,switch.thermostat_dhw_disinfecting,6,9,1,7,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,disinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_dhw_disinfection_day,select.thermostat_dhw_disinfectday,6,9,1,8,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,disinfecttime,disinfection time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_disinfection_time,number.thermostat_dhw_disinfecttime,6,9,15,9,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,dailyheating,daily heating,boolean, ,true,switch.thermostat_dhw_daily_heating,switch.thermostat_dhw_dailyheating,6,9,1,10,1 +RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410,thermostat,158,dailyheattime,daily heating time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_daily_heating_time,number.thermostat_dhw_dailyheattime,6,9,15,11,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 +RC100, CR10, Moduline 1000/1010,thermostat,165,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 +RC100, CR10, Moduline 1000/1010,thermostat,165,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 +RC100, CR10, Moduline 1000/1010,thermostat,165,intoffset,internal temperature offset,int8 (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset,6,0,1/10,46,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry,6,0,1,47,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,dampedoutdoortemp,damped outdoor temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp,6,0,1/10,48,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,floordrytemp,floor drying temperature,uint8 (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp,6,0,1,49,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building,6,0,1,50,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp,6,0,1,51,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping,6,0,1,52,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy,6,0,1,53,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp,6,0,1,54,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio,6,0,1/10,55,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor,6,0,1/10,56,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor,6,0,1/10,57,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler,6,0,1,58,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler,6,0,1,59,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,pvenabledhw,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenabledhw,6,0,1,60,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,pvraiseheat,raise heating with PV,int8 (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat,6,0,1,61,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,pvlowercool,lower cooling with PV,int8 (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool,6,0,1,62,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp,6,1,1/2,0,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/10,1,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,mode,operating mode,enum [manual\|auto], ,true,select.thermostat_hc1_operating_mode,select.thermostat_hc1_mode,6,1,1,3,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype,6,1,1,4,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp,6,1,1/2,5,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,manualtemp,manual temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp,6,1,1/2,6,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,comforttemp,comfort temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp,6,1,1/2,7,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,designtemp,design temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp,6,1,1,9,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,offsettemp,offset temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp,6,1,1,10,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp,6,1,1,11,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp,6,1,1,12,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,roominfluence,room influence,uint8 (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence,6,1,1,13,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,roominflfactor,room influence factor,uint8 (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor,6,1,1/10,14,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,curroominfl,current room influence,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl,6,1,1/10,15,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode,6,1,1,16,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,nofrosttemp,nofrost temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp,6,1,1,17,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp,6,1,1,18,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype,6,1,1,19,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode,6,1,1,20,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode,6,1,1,21,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode,6,1,1,22,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate,6,1,1,23,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,controlmode,control mode,enum [optimized\|simple\|n/a\|room\|power], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode,6,1,1,24,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program,6,1,1,25,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,tempautotemp,temporary set temperature automode,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp,6,1,1/2,26,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,remoteseltemp,temporary set temperature from remote,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_from_remote,number.thermostat_hc1_remoteseltemp,6,1,1/2,27,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,fastheatup,fast heatup,uint8 (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup,6,1,1,28,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization,6,1,1,29,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode,6,1,1,30,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,noreducetemp,no reduce below temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp,6,1,1,31,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,reducetemp,off/reduce switch temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp,6,1,1,32,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,dhwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_dhwprio,6,1,1,33,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,hpcooling,hp cooling,boolean, ,true,switch.thermostat_hc1_hp_cooling,switch.thermostat_hc1_hpcooling,6,1,1,34,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,coolingon,cooling on,boolean, ,false,binary_sensor.thermostat_hc1_cooling_on,binary_sensor.thermostat_hc1_coolingon,6,1,1,35,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,hpmode,HP Mode,enum [heating\|cooling\|heating & cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode,6,1,1,36,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,dewoffset,dew point offset,uint8 (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset,6,1,1,37,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,roomtempdiff,room temp difference,uint8 (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff,6,1,1,38,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,hpminflowtemp,HP min. flow temp.,uint8 (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp,6,1,1,39,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,control,control device,enum [RC310\|RC200\|RC100\|RC100H\|TC100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control,6,1,1,40,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,remotetemp,room temperature from remote,cmd [] (>=-1<=101),C,true,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp,6,1,1/10,41,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,remotehum,room humidity from remote,cmd [] (>=-1<=101),%,true,sensor.thermostat_hc1_room_humidity_from_remote,sensor.thermostat_hc1_remotehum,6,1,1,42,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,heatondelay,heat-on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay,6,1,1,43,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,heatoffdelay,heat-off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay,6,1,1,44,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,instantstart,instant start,uint8 (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart,6,1,1,45,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,boost,boost mode,boolean, ,true,switch.thermostat_hc1_boost_mode,switch.thermostat_hc1_boost,6,1,1,46,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,boosttime,boost time,uint8 (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime,6,1,1,47,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,coolstart,cooling starttemp,uint8 (>=20<=35),C,true,number.thermostat_hc1_cooling_starttemp,number.thermostat_hc1_coolstart,6,1,1,193,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,coolondelay,cooling on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_on_delay,number.thermostat_hc1_coolondelay,6,1,1,194,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,cooloffdelay,cooling off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_off_delay,number.thermostat_hc1_cooloffdelay,6,1,1,195,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,switchprogmode,switch program mode,enum [level\|absolute], ,true,select.thermostat_hc1_switch_program_mode,select.thermostat_hc1_switchprogmode,6,1,1,196,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,mode,operating mode,enum [off\|normal\|comfort\|auto\|own prog], ,true,select.thermostat_dhw_operating_mode,select.thermostat_dhw_mode,6,9,1,0,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,settemp,set temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_temperature,number.thermostat_dhw_settemp,6,9,1,1,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,settemplow,set low temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_low_temperature,number.thermostat_dhw_settemplow,6,9,1,2,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,circmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_dhw_circulation_pump_mode,select.thermostat_dhw_circmode,6,9,1,3,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,chargeduration,charge duration,uint8 (>=0<=3810),minutes,true,number.thermostat_dhw_charge_duration,number.thermostat_dhw_chargeduration,6,9,15,4,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge,6,9,1,5,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,extra,extra,uint8 (>=0<=254),C,false,sensor.thermostat_dhw_extra,sensor.thermostat_dhw_extra,6,9,1,6,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,disinfecting,disinfecting,boolean, ,true,switch.thermostat_dhw_disinfecting,switch.thermostat_dhw_disinfecting,6,9,1,7,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,disinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_dhw_disinfection_day,select.thermostat_dhw_disinfectday,6,9,1,8,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,disinfecttime,disinfection time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_disinfection_time,number.thermostat_dhw_disinfecttime,6,9,15,9,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,dailyheating,daily heating,boolean, ,true,switch.thermostat_dhw_daily_heating,switch.thermostat_dhw_dailyheating,6,9,1,10,1 +RC100, CR10, Moduline 1000/1010,thermostat,165,dailyheattime,daily heating time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_daily_heating_time,number.thermostat_dhw_dailyheattime,6,9,15,11,1 Rego 2000/3000,thermostat,172,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 Rego 2000/3000,thermostat,172,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 Rego 2000/3000,thermostat,172,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 @@ -4059,108 +4090,108 @@ Comfort+2RF,thermostat,246,haclimate,mqtt discovery current room temperature,enu Comfort+2RF,thermostat,246,mode,operating mode,enum [auto\|off], ,false,sensor.thermostat_hc1_operating_mode,sensor.thermostat_hc1_mode,6,1,1,3,1 Comfort+2RF,thermostat,246,modetype,mode type,enum [off\|on], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype,6,1,1,4,1 Comfort+2RF,thermostat,246,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp,6,1,1,18,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,intoffset,internal temperature offset,int8 (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset,6,0,1/10,46,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry,6,0,1,47,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,dampedoutdoortemp,damped outdoor temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp,6,0,1/10,48,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,floordrytemp,floor drying temperature,uint8 (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp,6,0,1,49,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building,6,0,1,50,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp,6,0,1,51,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping,6,0,1,52,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy,6,0,1,53,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp,6,0,1,54,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio,6,0,1/10,55,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor,6,0,1/10,56,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor,6,0,1/10,57,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler,6,0,1,58,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler,6,0,1,59,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,pvenabledhw,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenabledhw,6,0,1,60,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,pvraiseheat,raise heating with PV,int8 (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat,6,0,1,61,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,pvlowercool,lower cooling with PV,int8 (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool,6,0,1,62,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp,6,1,1/2,0,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/10,1,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,mode,operating mode,enum [off\|manual\|auto], ,true,select.thermostat_hc1_operating_mode,select.thermostat_hc1_mode,6,1,1,3,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype,6,1,1,4,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp,6,1,1/2,5,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,manualtemp,manual temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp,6,1,1/2,6,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,comforttemp,comfort temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp,6,1,1/2,7,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,designtemp,design temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp,6,1,1,9,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,offsettemp,offset temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp,6,1,1,10,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp,6,1,1,11,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp,6,1,1,12,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,roominfluence,room influence,uint8 (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence,6,1,1,13,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,roominflfactor,room influence factor,uint8 (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor,6,1,1/10,14,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,curroominfl,current room influence,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl,6,1,1/10,15,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode,6,1,1,16,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,nofrosttemp,nofrost temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp,6,1,1,17,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp,6,1,1,18,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype,6,1,1,19,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode,6,1,1,20,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode,6,1,1,21,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode,6,1,1,22,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate,6,1,1,23,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,controlmode,control mode,enum [weather compensated\|outside basepoint\|n/a\|room\|power\|constant], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode,6,1,1,24,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program,6,1,1,25,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,tempautotemp,temporary set temperature automode,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp,6,1,1/2,26,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,remoteseltemp,temporary set temperature from remote,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_from_remote,number.thermostat_hc1_remoteseltemp,6,1,1/2,27,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,fastheatup,fast heatup,uint8 (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup,6,1,1,28,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization,6,1,1,29,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode,6,1,1,30,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,noreducetemp,no reduce below temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp,6,1,1,31,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,reducetemp,off/reduce switch temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp,6,1,1,32,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,dhwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_dhwprio,6,1,1,33,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,hpcooling,hp cooling,boolean, ,true,switch.thermostat_hc1_hp_cooling,switch.thermostat_hc1_hpcooling,6,1,1,34,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,coolingon,cooling on,boolean, ,false,binary_sensor.thermostat_hc1_cooling_on,binary_sensor.thermostat_hc1_coolingon,6,1,1,35,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,hpmode,HP Mode,enum [heating\|cooling\|heating & cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode,6,1,1,36,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,dewoffset,dew point offset,uint8 (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset,6,1,1,37,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,roomtempdiff,room temp difference,uint8 (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff,6,1,1,38,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,hpminflowtemp,HP min. flow temp.,uint8 (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp,6,1,1,39,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,control,control device,enum [off\|-\|RC100\|RC100H\|-\|RC120RF\|RC220/RT800\|single], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control,6,1,1,40,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,remotetemp,room temperature from remote,cmd [] (>=-1<=101),C,true,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp,6,1,1/10,41,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,remotehum,room humidity from remote,cmd [] (>=-1<=101),%,true,sensor.thermostat_hc1_room_humidity_from_remote,sensor.thermostat_hc1_remotehum,6,1,1,42,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,heatondelay,heat-on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay,6,1,1,43,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,heatoffdelay,heat-off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay,6,1,1,44,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,instantstart,instant start,uint8 (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart,6,1,1,45,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,boost,boost mode,boolean, ,true,switch.thermostat_hc1_boost_mode,switch.thermostat_hc1_boost,6,1,1,46,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,boosttime,boost time,uint8 (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime,6,1,1,47,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,coolstart,cooling starttemp,uint8 (>=20<=35),C,true,number.thermostat_hc1_cooling_starttemp,number.thermostat_hc1_coolstart,6,1,1,193,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,coolondelay,cooling on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_on_delay,number.thermostat_hc1_coolondelay,6,1,1,194,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,cooloffdelay,cooling off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_off_delay,number.thermostat_hc1_cooloffdelay,6,1,1,195,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,switchprogmode,switch program mode,enum [level\|absolute], ,true,select.thermostat_hc1_switch_program_mode,select.thermostat_hc1_switchprogmode,6,1,1,196,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,mode,operating mode,enum [off\|eco+\|eco\|comfort\|auto], ,true,select.thermostat_dhw_operating_mode,select.thermostat_dhw_mode,6,9,1,0,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,settemp,set temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_temperature,number.thermostat_dhw_settemp,6,9,1,1,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,settemplow,set low temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_low_temperature,number.thermostat_dhw_settemplow,6,9,1,2,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,circmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_dhw_circulation_pump_mode,select.thermostat_dhw_circmode,6,9,1,3,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,chargeduration,charge duration,uint8 (>=0<=3810),minutes,true,number.thermostat_dhw_charge_duration,number.thermostat_dhw_chargeduration,6,9,15,4,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge,6,9,1,5,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,extra,extra,uint8 (>=0<=254),C,false,sensor.thermostat_dhw_extra,sensor.thermostat_dhw_extra,6,9,1,6,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,disinfecting,disinfecting,boolean, ,true,switch.thermostat_dhw_disinfecting,switch.thermostat_dhw_disinfecting,6,9,1,7,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,disinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_dhw_disinfection_day,select.thermostat_dhw_disinfectday,6,9,1,8,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,disinfecttime,disinfection time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_disinfection_time,number.thermostat_dhw_disinfecttime,6,9,15,9,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,dailyheating,daily heating,boolean, ,true,switch.thermostat_dhw_daily_heating,switch.thermostat_dhw_dailyheating,6,9,1,10,1 -Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,dailyheattime,daily heating time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_daily_heating_time,number.thermostat_dhw_dailyheattime,6,9,15,11,1 -ES72/RC20,thermostat,66,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 -ES72/RC20,thermostat,66,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 -ES72/RC20,thermostat,66,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 -ES72/RC20,thermostat,66,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp,6,0,1,51,1 -ES72/RC20,thermostat,66,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp,6,1,1/2,0,1 -ES72/RC20,thermostat,66,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/10,1,1 -ES72/RC20,thermostat,66,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 -ES72/RC20,thermostat,66,mode,operating mode,enum [night\|day\|auto], ,true,select.thermostat_hc1_operating_mode,select.thermostat_hc1_mode,6,1,1,3,1 -ES72/RC20,thermostat,66,modetype,mode type,enum [night\|day], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype,6,1,1,4,1 -ES72/RC20,thermostat,66,daytemp,day temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp,6,1,1/2,48,1 -ES72/RC20,thermostat,66,nighttemp,night temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp,6,1,1/2,49,1 -ES72/RC20,thermostat,66,program,program,enum [family\|morning\|evening\|am\|pm\|midday\|singles\|seniors], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program,6,1,1,25,1 -ES72/RC20,thermostat,66,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp,6,1,1,11,1 -ES72/RC20,thermostat,66,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp,6,1,1,12,1 -ES72/RC20,thermostat,66,tempautotemp,temporary set temperature automode,uint8 (>=0<=127),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp,6,1,1/2,26,1 -ES72/RC20,thermostat,66,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype,6,1,1,19,1 -ES72/RC20,thermostat,66,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 -ES72/RC20,thermostat,66,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode,6,1,1,22,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 +Rego 3000, UI800, Logamatic BC400,thermostat,253,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 +Rego 3000, UI800, Logamatic BC400,thermostat,253,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 +Rego 3000, UI800, Logamatic BC400,thermostat,253,intoffset,internal temperature offset,int8 (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset,6,0,1/10,46,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry,6,0,1,47,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,dampedoutdoortemp,damped outdoor temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp,6,0,1/10,48,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,floordrytemp,floor drying temperature,uint8 (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp,6,0,1,49,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building,6,0,1,50,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp,6,0,1,51,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping,6,0,1,52,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy,6,0,1,53,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp,6,0,1,54,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio,6,0,1/10,55,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor,6,0,1/10,56,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor,6,0,1/10,57,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler,6,0,1,58,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler,6,0,1,59,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,pvenabledhw,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenabledhw,6,0,1,60,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,pvraiseheat,raise heating with PV,int8 (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat,6,0,1,61,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,pvlowercool,lower cooling with PV,int8 (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool,6,0,1,62,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp,6,1,1/2,0,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/10,1,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,mode,operating mode,enum [off\|manual\|auto], ,true,select.thermostat_hc1_operating_mode,select.thermostat_hc1_mode,6,1,1,3,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype,6,1,1,4,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp,6,1,1/2,5,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,manualtemp,manual temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp,6,1,1/2,6,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,comforttemp,comfort temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp,6,1,1/2,7,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,designtemp,design temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp,6,1,1,9,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,offsettemp,offset temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp,6,1,1,10,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp,6,1,1,11,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp,6,1,1,12,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,roominfluence,room influence,uint8 (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence,6,1,1,13,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,roominflfactor,room influence factor,uint8 (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor,6,1,1/10,14,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,curroominfl,current room influence,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl,6,1,1/10,15,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode,6,1,1,16,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,nofrosttemp,nofrost temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp,6,1,1,17,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp,6,1,1,18,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype,6,1,1,19,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode,6,1,1,20,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode,6,1,1,21,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode,6,1,1,22,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate,6,1,1,23,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,controlmode,control mode,enum [weather compensated\|outside basepoint\|n/a\|room\|power\|constant], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode,6,1,1,24,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program,6,1,1,25,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,tempautotemp,temporary set temperature automode,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp,6,1,1/2,26,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,remoteseltemp,temporary set temperature from remote,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_from_remote,number.thermostat_hc1_remoteseltemp,6,1,1/2,27,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,fastheatup,fast heatup,uint8 (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup,6,1,1,28,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization,6,1,1,29,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode,6,1,1,30,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,noreducetemp,no reduce below temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp,6,1,1,31,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,reducetemp,off/reduce switch temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp,6,1,1,32,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,dhwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_dhwprio,6,1,1,33,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,hpcooling,hp cooling,boolean, ,true,switch.thermostat_hc1_hp_cooling,switch.thermostat_hc1_hpcooling,6,1,1,34,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,coolingon,cooling on,boolean, ,false,binary_sensor.thermostat_hc1_cooling_on,binary_sensor.thermostat_hc1_coolingon,6,1,1,35,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,hpmode,HP Mode,enum [heating\|cooling\|heating & cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode,6,1,1,36,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,dewoffset,dew point offset,uint8 (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset,6,1,1,37,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,roomtempdiff,room temp difference,uint8 (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff,6,1,1,38,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,hpminflowtemp,HP min. flow temp.,uint8 (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp,6,1,1,39,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,control,control device,enum [off\|-\|RC100\|RC100H\|-\|RC120RF\|RC220/RT800\|single], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control,6,1,1,40,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,remotetemp,room temperature from remote,cmd [] (>=-1<=101),C,true,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp,6,1,1/10,41,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,remotehum,room humidity from remote,cmd [] (>=-1<=101),%,true,sensor.thermostat_hc1_room_humidity_from_remote,sensor.thermostat_hc1_remotehum,6,1,1,42,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,heatondelay,heat-on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay,6,1,1,43,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,heatoffdelay,heat-off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay,6,1,1,44,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,instantstart,instant start,uint8 (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart,6,1,1,45,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,boost,boost mode,boolean, ,true,switch.thermostat_hc1_boost_mode,switch.thermostat_hc1_boost,6,1,1,46,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,boosttime,boost time,uint8 (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime,6,1,1,47,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,coolstart,cooling starttemp,uint8 (>=20<=35),C,true,number.thermostat_hc1_cooling_starttemp,number.thermostat_hc1_coolstart,6,1,1,193,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,coolondelay,cooling on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_on_delay,number.thermostat_hc1_coolondelay,6,1,1,194,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,cooloffdelay,cooling off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_off_delay,number.thermostat_hc1_cooloffdelay,6,1,1,195,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,switchprogmode,switch program mode,enum [level\|absolute], ,true,select.thermostat_hc1_switch_program_mode,select.thermostat_hc1_switchprogmode,6,1,1,196,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,mode,operating mode,enum [off\|eco+\|eco\|comfort\|auto], ,true,select.thermostat_dhw_operating_mode,select.thermostat_dhw_mode,6,9,1,0,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,settemp,set temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_temperature,number.thermostat_dhw_settemp,6,9,1,1,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,settemplow,set low temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_low_temperature,number.thermostat_dhw_settemplow,6,9,1,2,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,circmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_dhw_circulation_pump_mode,select.thermostat_dhw_circmode,6,9,1,3,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,chargeduration,charge duration,uint8 (>=0<=3810),minutes,true,number.thermostat_dhw_charge_duration,number.thermostat_dhw_chargeduration,6,9,15,4,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge,6,9,1,5,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,extra,extra,uint8 (>=0<=254),C,false,sensor.thermostat_dhw_extra,sensor.thermostat_dhw_extra,6,9,1,6,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,disinfecting,disinfecting,boolean, ,true,switch.thermostat_dhw_disinfecting,switch.thermostat_dhw_disinfecting,6,9,1,7,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,disinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_dhw_disinfection_day,select.thermostat_dhw_disinfectday,6,9,1,8,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,disinfecttime,disinfection time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_disinfection_time,number.thermostat_dhw_disinfecttime,6,9,15,9,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,dailyheating,daily heating,boolean, ,true,switch.thermostat_dhw_daily_heating,switch.thermostat_dhw_dailyheating,6,9,1,10,1 +Rego 3000, UI800, Logamatic BC400,thermostat,253,dailyheattime,daily heating time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_daily_heating_time,number.thermostat_dhw_dailyheattime,6,9,15,11,1 +ES72, RC20,thermostat,66,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 +ES72, RC20,thermostat,66,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 +ES72, RC20,thermostat,66,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 +ES72, RC20,thermostat,66,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp,6,0,1,51,1 +ES72, RC20,thermostat,66,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp,6,1,1/2,0,1 +ES72, RC20,thermostat,66,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/10,1,1 +ES72, RC20,thermostat,66,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 +ES72, RC20,thermostat,66,mode,operating mode,enum [night\|day\|auto], ,true,select.thermostat_hc1_operating_mode,select.thermostat_hc1_mode,6,1,1,3,1 +ES72, RC20,thermostat,66,modetype,mode type,enum [night\|day], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype,6,1,1,4,1 +ES72, RC20,thermostat,66,daytemp,day temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp,6,1,1/2,48,1 +ES72, RC20,thermostat,66,nighttemp,night temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp,6,1,1/2,49,1 +ES72, RC20,thermostat,66,program,program,enum [family\|morning\|evening\|am\|pm\|midday\|singles\|seniors], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program,6,1,1,25,1 +ES72, RC20,thermostat,66,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp,6,1,1,11,1 +ES72, RC20,thermostat,66,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp,6,1,1,12,1 +ES72, RC20,thermostat,66,tempautotemp,temporary set temperature automode,uint8 (>=0<=127),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp,6,1,1/2,26,1 +ES72, RC20,thermostat,66,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype,6,1,1,19,1 +ES72, RC20,thermostat,66,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 +ES72, RC20,thermostat,66,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode,6,1,1,22,1 ES73,thermostat,76,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 ES73,thermostat,76,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 ES73,thermostat,76,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 @@ -4226,24 +4257,24 @@ ES73,thermostat,76,switchtimeWW,program switchtime warm water,string, ,true,sens ES73,thermostat,76,circswitchtime,circulation program switchtime,string, ,true,sensor.thermostat_dhw_circulation_program_switchtime,sensor.thermostat_dhw_circswitchtime,6,9,1,25,8 ES73,thermostat,76,holidays,holiday dates,string, ,true,sensor.thermostat_dhw_holiday_dates,sensor.thermostat_dhw_holidays,6,9,1,33,13 ES73,thermostat,76,vacations,vacation dates,string, ,true,sensor.thermostat_dhw_vacation_dates,sensor.thermostat_dhw_vacations,6,9,1,46,13 -ES72/RC20,thermostat,113,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 -ES72/RC20,thermostat,113,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 -ES72/RC20,thermostat,113,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 -ES72/RC20,thermostat,113,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp,6,0,1,51,1 -ES72/RC20,thermostat,113,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp,6,1,1/2,0,1 -ES72/RC20,thermostat,113,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/10,1,1 -ES72/RC20,thermostat,113,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 -ES72/RC20,thermostat,113,mode,operating mode,enum [night\|day\|auto], ,true,select.thermostat_hc1_operating_mode,select.thermostat_hc1_mode,6,1,1,3,1 -ES72/RC20,thermostat,113,modetype,mode type,enum [night\|day], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype,6,1,1,4,1 -ES72/RC20,thermostat,113,daytemp,day temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp,6,1,1/2,48,1 -ES72/RC20,thermostat,113,nighttemp,night temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp,6,1,1/2,49,1 -ES72/RC20,thermostat,113,program,program,enum [family\|morning\|evening\|am\|pm\|midday\|singles\|seniors], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program,6,1,1,25,1 -ES72/RC20,thermostat,113,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp,6,1,1,11,1 -ES72/RC20,thermostat,113,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp,6,1,1,12,1 -ES72/RC20,thermostat,113,tempautotemp,temporary set temperature automode,uint8 (>=0<=127),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp,6,1,1/2,26,1 -ES72/RC20,thermostat,113,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype,6,1,1,19,1 -ES72/RC20,thermostat,113,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 -ES72/RC20,thermostat,113,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode,6,1,1,22,1 +ES72, RC20,thermostat,113,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 +ES72, RC20,thermostat,113,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 +ES72, RC20,thermostat,113,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 +ES72, RC20,thermostat,113,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp,6,0,1,51,1 +ES72, RC20,thermostat,113,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp,6,1,1/2,0,1 +ES72, RC20,thermostat,113,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/10,1,1 +ES72, RC20,thermostat,113,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 +ES72, RC20,thermostat,113,mode,operating mode,enum [night\|day\|auto], ,true,select.thermostat_hc1_operating_mode,select.thermostat_hc1_mode,6,1,1,3,1 +ES72, RC20,thermostat,113,modetype,mode type,enum [night\|day], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype,6,1,1,4,1 +ES72, RC20,thermostat,113,daytemp,day temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp,6,1,1/2,48,1 +ES72, RC20,thermostat,113,nighttemp,night temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp,6,1,1/2,49,1 +ES72, RC20,thermostat,113,program,program,enum [family\|morning\|evening\|am\|pm\|midday\|singles\|seniors], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program,6,1,1,25,1 +ES72, RC20,thermostat,113,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp,6,1,1,11,1 +ES72, RC20,thermostat,113,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp,6,1,1,12,1 +ES72, RC20,thermostat,113,tempautotemp,temporary set temperature automode,uint8 (>=0<=127),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp,6,1,1/2,26,1 +ES72, RC20,thermostat,113,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype,6,1,1,19,1 +ES72, RC20,thermostat,113,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 +ES72, RC20,thermostat,113,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode,6,1,1,22,1 ES79,thermostat,156,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 ES79,thermostat,156,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 ES79,thermostat,156,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 @@ -4691,24 +4722,24 @@ FW120,thermostat,192,roominflfactor,room influence factor,uint8 (>=0<=100),%,tru FW120,thermostat,192,heatingtype,heating type,enum [off\|heatingcurve\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype,6,1,1,19,1 FW120,thermostat,192,controlmode,control mode,enum [off\|unmixed\|unmixed IPM\|mixed IPM], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode,6,1,1,24,1 FW120,thermostat,192,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge,6,9,1,5,1 -RT800/RC220,thermostat,3,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 -RT800/RC220,thermostat,3,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 -RT800/RC220,thermostat,3,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 -RT800/RC220,thermostat,3,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp,6,1,1/2,0,1 -RT800/RC220,thermostat,3,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/10,1,1 -RT800/RC220,thermostat,3,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 +RT800, RC220,thermostat,3,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 +RT800, RC220,thermostat,3,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 +RT800, RC220,thermostat,3,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 +RT800, RC220,thermostat,3,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp,6,1,1/2,0,1 +RT800, RC220,thermostat,3,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/10,1,1 +RT800, RC220,thermostat,3,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 RC100H,thermostat,200,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 RC100H,thermostat,200,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 RC100H,thermostat,200,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 RC100H,thermostat,200,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp,6,1,1/2,0,1 RC100H,thermostat,200,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/10,1,1 RC100H,thermostat,200,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 -TR120RF/CR20RF,thermostat,249,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 -TR120RF/CR20RF,thermostat,249,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 -TR120RF/CR20RF,thermostat,249,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 -TR120RF/CR20RF,thermostat,249,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp,6,1,1/2,0,1 -TR120RF/CR20RF,thermostat,249,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/10,1,1 -TR120RF/CR20RF,thermostat,249,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 +TR120RF, CR20RF,thermostat,249,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 +TR120RF, CR20RF,thermostat,249,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 +TR120RF, CR20RF,thermostat,249,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 +TR120RF, CR20RF,thermostat,249,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp,6,1,1/2,0,1 +TR120RF, CR20RF,thermostat,249,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/10,1,1 +TR120RF, CR20RF,thermostat,249,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 MM10,mixer,69,flowtemphc,flow temperature (TC1),uint16 (>=0<=3199),C,false,sensor.mixer_hc1_flow_temperature_(TC1),sensor.mixer_hc1_flowtemphc,7,1,1/10,0,1 MM10,mixer,69,valvestatus,mixing valve actuator (VC1),int8 (>=-100<=100),%,false,sensor.mixer_hc1_mixing_valve_actuator_(VC1),sensor.mixer_hc1_valvestatus,7,1,1,1,1 MM10,mixer,69,flowsettemp,setpoint flow temperature,uint8 (>=0<=254),C,true,number.mixer_hc1_setpoint_flow_temperature,number.mixer_hc1_flowsettemp,7,1,1,2,1 @@ -4845,114 +4876,114 @@ SM50,solar,162,heatcntrettemp,heat counter return temperature,uint16 (>=0<=3199) SM50,solar,162,heatcnt,heat counter impulses,uint8 (>=0<=254), ,false,sensor.solar_heat_counter_impulses,sensor.solar_heatcnt,8,0,1,60,1 SM50,solar,162,swapflowtemp,swap flow temperature (TS14),uint16 (>=0<=3199),C,false,sensor.solar_swap_flow_temperature_(TS14),sensor.solar_swapflowtemp,8,0,1/10,61,1 SM50,solar,162,swaprettemp,swap return temperature (TS15),uint16 (>=0<=3199),C,false,sensor.solar_swap_return_temperature_(TS15),sensor.solar_swaprettemp,8,0,1/10,62,1 -SM100/MS100,solar,163,collectortemp,collector temperature (TS1),int16 (>=-3199<=3199),C,false,sensor.solar_collector_temperature_(TS1),sensor.solar_collectortemp,8,0,1/10,0,1 -SM100/MS100,solar,163,cylbottomtemp,cylinder bottom temperature (TS2),int16 (>=-3199<=3199),C,false,sensor.solar_cylinder_bottom_temperature_(TS2),sensor.solar_cylbottomtemp,8,0,1/10,1,1 -SM100/MS100,solar,163,solarpump,pump (PS1),boolean, ,false,binary_sensor.solar_pump_(PS1),binary_sensor.solar_solarpump,8,0,1,2,1 -SM100/MS100,solar,163,pumpworktime,pump working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_working_time,sensor.solar_pumpworktime,8,0,1,3,2 -SM100/MS100,solar,163,cylmaxtemp,maximum cylinder temperature,uint8 (>=0<=254),C,true,number.solar_maximum_cylinder_temperature,number.solar_cylmaxtemp,8,0,1,5,1 -SM100/MS100,solar,163,collectorshutdown,collector shutdown,boolean, ,false,binary_sensor.solar_collector_shutdown,binary_sensor.solar_collectorshutdown,8,0,1,6,1 -SM100/MS100,solar,163,cylheated,cyl heated,boolean, ,false,binary_sensor.solar_cyl_heated,binary_sensor.solar_cylheated,8,0,1,7,1 -SM100/MS100,solar,163,solarpumpmod,pump modulation (PS1),uint8 (>=0<=100),%,false,sensor.solar_pump_modulation_(PS1),sensor.solar_solarpumpmod,8,0,1,8,1 -SM100/MS100,solar,163,pumpminmod,minimum pump modulation,uint8 (>=0<=100),%,true,number.solar_minimum_pump_modulation,number.solar_pumpminmod,8,0,5,9,1 -SM100/MS100,solar,163,turnondiff,pump turn on difference,uint8 (>=0<=25),C,true,number.solar_pump_turn_on_difference,number.solar_turnondiff,8,0,1/10,10,1 -SM100/MS100,solar,163,turnoffdiff,pump turn off difference,uint8 (>=0<=25),C,true,number.solar_pump_turn_off_difference,number.solar_turnoffdiff,8,0,1/10,11,1 -SM100/MS100,solar,163,collector2temp,collector 2 temperature (TS7),int16 (>=-3199<=3199),C,false,sensor.solar_collector_2_temperature_(TS7),sensor.solar_collector2temp,8,0,1/10,20,1 -SM100/MS100,solar,163,cylmiddletemp,cylinder middle temperature (TS3),int16 (>=-3199<=3199),C,false,sensor.solar_cylinder_middle_temperature_(TS3),sensor.solar_cylmiddletemp,8,0,1/10,17,1 -SM100/MS100,solar,163,retheatassist,return temperature heat assistance (TS4),int16 (>=-3199<=3199),C,false,sensor.solar_return_temperature_heat_assistance_(TS4),sensor.solar_retheatassist,8,0,1/10,18,1 -SM100/MS100,solar,163,heatassistvalve,heat assistance valve (M1),boolean, ,false,binary_sensor.solar_heat_assistance_valve_(M1),binary_sensor.solar_heatassistvalve,8,0,1,19,1 -SM100/MS100,solar,163,heatassistpower,heat assistance valve power (M1),uint8 (>=0<=100),%,false,sensor.solar_heat_assistance_valve_power_(M1),sensor.solar_heatassistpower,8,0,1,21,1 -SM100/MS100,solar,163,solarpump2,pump 2 (PS4),boolean, ,false,binary_sensor.solar_pump_2_(PS4),binary_sensor.solar_solarpump2,8,0,1,22,1 -SM100/MS100,solar,163,solarpump2mod,pump 2 modulation (PS4),uint8 (>=0<=100),%,false,sensor.solar_pump_2_modulation_(PS4),sensor.solar_solarpump2mod,8,0,1,23,1 -SM100/MS100,solar,163,cyl2bottomtemp,second cylinder bottom temperature (TS5),int16 (>=-3199<=3199),C,false,sensor.solar_second_cylinder_bottom_temperature_(TS5),sensor.solar_cyl2bottomtemp,8,0,1/10,24,1 -SM100/MS100,solar,163,heatexchangertemp,heat exchanger temperature (TS6),int16 (>=-3199<=3199),C,false,sensor.solar_heat_exchanger_temperature_(TS6),sensor.solar_heatexchangertemp,8,0,1/10,25,1 -SM100/MS100,solar,163,cylpumpmod,cylinder pump modulation (PS5),uint8 (>=0<=100),%,false,sensor.solar_cylinder_pump_modulation_(PS5),sensor.solar_cylpumpmod,8,0,1,26,1 -SM100/MS100,solar,163,valvestatus,valve status,boolean, ,false,binary_sensor.solar_valve_status,binary_sensor.solar_valvestatus,8,0,1,27,1 -SM100/MS100,solar,163,vs1status,valve status VS1,boolean, ,false,binary_sensor.solar_valve_status_VS1,binary_sensor.solar_vs1status,8,0,1,28,1 -SM100/MS100,solar,163,collectormaxtemp,maximum collector temperature,uint8 (>=0<=254),C,true,number.solar_maximum_collector_temperature,number.solar_collectormaxtemp,8,0,1,29,1 -SM100/MS100,solar,163,collectormintemp,minimum collector temperature,uint8 (>=0<=254),C,true,number.solar_minimum_collector_temperature,number.solar_collectormintemp,8,0,1,30,1 -SM100/MS100,solar,163,energylasthour,energy last hour,uint24 (>=0<=1677721),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour,8,0,1/10,13,2 -SM100/MS100,solar,163,energytoday,total energy today,uint24 (>=0<=16777213),Wh,false,sensor.solar_total_energy_today,sensor.solar_energytoday,8,0,1,31,2 -SM100/MS100,solar,163,energytotal,total energy,uint24 (>=0<=1677721),kWh,false,sensor.solar_total_energy,sensor.solar_energytotal,8,0,1/10,33,2 -SM100/MS100,solar,163,pump2worktime,pump 2 working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_2_working_time,sensor.solar_pump2worktime,8,0,1,35,2 -SM100/MS100,solar,163,m1worktime,differential control working time,time (>=0<=16777213),minutes,false,sensor.solar_differential_control_working_time,sensor.solar_m1worktime,8,0,1,37,2 -SM100/MS100,solar,163,heattransfersystem,heattransfer system,boolean, ,true,switch.solar_heattransfer_system,switch.solar_heattransfersystem,8,0,1,39,1 -SM100/MS100,solar,163,externalcyl,external cylinder,boolean, ,true,switch.solar_external_cylinder,switch.solar_externalcyl,8,0,1,40,1 -SM100/MS100,solar,163,thermaldisinfect,thermal disinfection,boolean, ,true,switch.solar_thermal_disinfection,switch.solar_thermaldisinfect,8,0,1,41,1 -SM100/MS100,solar,163,heatmetering,heatmetering,boolean, ,true,switch.solar_heatmetering,switch.solar_heatmetering,8,0,1,42,1 -SM100/MS100,solar,163,activated,activated,boolean, ,true,switch.solar_activated,switch.solar_activated,8,0,1,43,1 -SM100/MS100,solar,163,solarpumpmode,solar pump mode,enum [constant\|pwm\|analog], ,true,select.solar_solar_pump_mode,select.solar_solarpumpmode,8,0,1,44,1 -SM100/MS100,solar,163,solarpumpkick,solar pump kick,boolean, ,true,switch.solar_solar_pump_kick,switch.solar_solarpumpkick,8,0,1,45,1 -SM100/MS100,solar,163,plainwatermode,plain water mode,boolean, ,true,switch.solar_plain_water_mode,switch.solar_plainwatermode,8,0,1,46,1 -SM100/MS100,solar,163,doublematchflow,doublematchflow,boolean, ,true,switch.solar_doublematchflow,switch.solar_doublematchflow,8,0,1,47,1 -SM100/MS100,solar,163,pump2minmod,minimum pump 2 modulation,uint8 (>=0<=100),%,true,number.solar_minimum_pump_2_modulation,number.solar_pump2minmod,8,0,1,48,1 -SM100/MS100,solar,163,turnondiff2,pump 2 turn on difference,uint8 (>=0<=25),C,true,number.solar_pump_2_turn_on_difference,number.solar_turnondiff2,8,0,1/10,49,1 -SM100/MS100,solar,163,turnoffdiff2,pump 2 turn off difference,uint8 (>=0<=25),C,true,number.solar_pump_2_turn_off_difference,number.solar_turnoffdiff2,8,0,1/10,50,1 -SM100/MS100,solar,163,pump2kick,pump kick 2,boolean, ,true,switch.solar_pump_kick_2,switch.solar_pump2kick,8,0,1,51,1 -SM100/MS100,solar,163,climatezone,climate zone,uint8 (>=0<=254), ,true,number.solar_climate_zone,number.solar_climatezone,8,0,1,52,1 -SM100/MS100,solar,163,collector1area,collector 1 area,uint16 (>=0<=3199),m²,true,number.solar_collector_1_area,number.solar_collector1area,8,0,1/10,53,1 -SM100/MS100,solar,163,collector1type,collector 1 type,enum [flat\|vacuum], ,true,select.solar_collector_1_type,select.solar_collector1type,8,0,1,54,1 -SM100/MS100,solar,163,collector2area,collector 2 area,uint16 (>=0<=3199),m²,true,number.solar_collector_2_area,number.solar_collector2area,8,0,1/10,55,1 -SM100/MS100,solar,163,collector2type,collector 2 type,enum [flat\|vacuum], ,true,select.solar_collector_2_type,select.solar_collector2type,8,0,1,56,1 -SM100/MS100,solar,163,cylpriority,cylinder priority,enum [cyl 1\|cyl 2], ,true,select.solar_cylinder_priority,select.solar_cylpriority,8,0,1,57,1 -SM100/MS100,solar,163,heatcntflowtemp,heat counter flow temperature,uint16 (>=0<=3199),C,false,sensor.solar_heat_counter_flow_temperature,sensor.solar_heatcntflowtemp,8,0,1/10,58,1 -SM100/MS100,solar,163,heatcntrettemp,heat counter return temperature,uint16 (>=0<=3199),C,false,sensor.solar_heat_counter_return_temperature,sensor.solar_heatcntrettemp,8,0,1/10,59,1 -SM100/MS100,solar,163,heatcnt,heat counter impulses,uint8 (>=0<=254), ,false,sensor.solar_heat_counter_impulses,sensor.solar_heatcnt,8,0,1,60,1 -SM100/MS100,solar,163,swapflowtemp,swap flow temperature (TS14),uint16 (>=0<=3199),C,false,sensor.solar_swap_flow_temperature_(TS14),sensor.solar_swapflowtemp,8,0,1/10,61,1 -SM100/MS100,solar,163,swaprettemp,swap return temperature (TS15),uint16 (>=0<=3199),C,false,sensor.solar_swap_return_temperature_(TS15),sensor.solar_swaprettemp,8,0,1/10,62,1 -SM200/MS200,solar,164,collectortemp,collector temperature (TS1),int16 (>=-3199<=3199),C,false,sensor.solar_collector_temperature_(TS1),sensor.solar_collectortemp,8,0,1/10,0,1 -SM200/MS200,solar,164,cylbottomtemp,cylinder bottom temperature (TS2),int16 (>=-3199<=3199),C,false,sensor.solar_cylinder_bottom_temperature_(TS2),sensor.solar_cylbottomtemp,8,0,1/10,1,1 -SM200/MS200,solar,164,solarpump,pump (PS1),boolean, ,false,binary_sensor.solar_pump_(PS1),binary_sensor.solar_solarpump,8,0,1,2,1 -SM200/MS200,solar,164,pumpworktime,pump working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_working_time,sensor.solar_pumpworktime,8,0,1,3,2 -SM200/MS200,solar,164,cylmaxtemp,maximum cylinder temperature,uint8 (>=0<=254),C,true,number.solar_maximum_cylinder_temperature,number.solar_cylmaxtemp,8,0,1,5,1 -SM200/MS200,solar,164,collectorshutdown,collector shutdown,boolean, ,false,binary_sensor.solar_collector_shutdown,binary_sensor.solar_collectorshutdown,8,0,1,6,1 -SM200/MS200,solar,164,cylheated,cyl heated,boolean, ,false,binary_sensor.solar_cyl_heated,binary_sensor.solar_cylheated,8,0,1,7,1 -SM200/MS200,solar,164,solarpumpmod,pump modulation (PS1),uint8 (>=0<=100),%,false,sensor.solar_pump_modulation_(PS1),sensor.solar_solarpumpmod,8,0,1,8,1 -SM200/MS200,solar,164,pumpminmod,minimum pump modulation,uint8 (>=0<=100),%,true,number.solar_minimum_pump_modulation,number.solar_pumpminmod,8,0,5,9,1 -SM200/MS200,solar,164,turnondiff,pump turn on difference,uint8 (>=0<=25),C,true,number.solar_pump_turn_on_difference,number.solar_turnondiff,8,0,1/10,10,1 -SM200/MS200,solar,164,turnoffdiff,pump turn off difference,uint8 (>=0<=25),C,true,number.solar_pump_turn_off_difference,number.solar_turnoffdiff,8,0,1/10,11,1 -SM200/MS200,solar,164,collector2temp,collector 2 temperature (TS7),int16 (>=-3199<=3199),C,false,sensor.solar_collector_2_temperature_(TS7),sensor.solar_collector2temp,8,0,1/10,20,1 -SM200/MS200,solar,164,cylmiddletemp,cylinder middle temperature (TS3),int16 (>=-3199<=3199),C,false,sensor.solar_cylinder_middle_temperature_(TS3),sensor.solar_cylmiddletemp,8,0,1/10,17,1 -SM200/MS200,solar,164,retheatassist,return temperature heat assistance (TS4),int16 (>=-3199<=3199),C,false,sensor.solar_return_temperature_heat_assistance_(TS4),sensor.solar_retheatassist,8,0,1/10,18,1 -SM200/MS200,solar,164,heatassistvalve,heat assistance valve (M1),boolean, ,false,binary_sensor.solar_heat_assistance_valve_(M1),binary_sensor.solar_heatassistvalve,8,0,1,19,1 -SM200/MS200,solar,164,heatassistpower,heat assistance valve power (M1),uint8 (>=0<=100),%,false,sensor.solar_heat_assistance_valve_power_(M1),sensor.solar_heatassistpower,8,0,1,21,1 -SM200/MS200,solar,164,solarpump2,pump 2 (PS4),boolean, ,false,binary_sensor.solar_pump_2_(PS4),binary_sensor.solar_solarpump2,8,0,1,22,1 -SM200/MS200,solar,164,solarpump2mod,pump 2 modulation (PS4),uint8 (>=0<=100),%,false,sensor.solar_pump_2_modulation_(PS4),sensor.solar_solarpump2mod,8,0,1,23,1 -SM200/MS200,solar,164,cyl2bottomtemp,second cylinder bottom temperature (TS5),int16 (>=-3199<=3199),C,false,sensor.solar_second_cylinder_bottom_temperature_(TS5),sensor.solar_cyl2bottomtemp,8,0,1/10,24,1 -SM200/MS200,solar,164,heatexchangertemp,heat exchanger temperature (TS6),int16 (>=-3199<=3199),C,false,sensor.solar_heat_exchanger_temperature_(TS6),sensor.solar_heatexchangertemp,8,0,1/10,25,1 -SM200/MS200,solar,164,cylpumpmod,cylinder pump modulation (PS5),uint8 (>=0<=100),%,false,sensor.solar_cylinder_pump_modulation_(PS5),sensor.solar_cylpumpmod,8,0,1,26,1 -SM200/MS200,solar,164,valvestatus,valve status,boolean, ,false,binary_sensor.solar_valve_status,binary_sensor.solar_valvestatus,8,0,1,27,1 -SM200/MS200,solar,164,vs1status,valve status VS1,boolean, ,false,binary_sensor.solar_valve_status_VS1,binary_sensor.solar_vs1status,8,0,1,28,1 -SM200/MS200,solar,164,collectormaxtemp,maximum collector temperature,uint8 (>=0<=254),C,true,number.solar_maximum_collector_temperature,number.solar_collectormaxtemp,8,0,1,29,1 -SM200/MS200,solar,164,collectormintemp,minimum collector temperature,uint8 (>=0<=254),C,true,number.solar_minimum_collector_temperature,number.solar_collectormintemp,8,0,1,30,1 -SM200/MS200,solar,164,energylasthour,energy last hour,uint24 (>=0<=1677721),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour,8,0,1/10,13,2 -SM200/MS200,solar,164,energytoday,total energy today,uint24 (>=0<=16777213),Wh,false,sensor.solar_total_energy_today,sensor.solar_energytoday,8,0,1,31,2 -SM200/MS200,solar,164,energytotal,total energy,uint24 (>=0<=1677721),kWh,false,sensor.solar_total_energy,sensor.solar_energytotal,8,0,1/10,33,2 -SM200/MS200,solar,164,pump2worktime,pump 2 working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_2_working_time,sensor.solar_pump2worktime,8,0,1,35,2 -SM200/MS200,solar,164,m1worktime,differential control working time,time (>=0<=16777213),minutes,false,sensor.solar_differential_control_working_time,sensor.solar_m1worktime,8,0,1,37,2 -SM200/MS200,solar,164,heattransfersystem,heattransfer system,boolean, ,true,switch.solar_heattransfer_system,switch.solar_heattransfersystem,8,0,1,39,1 -SM200/MS200,solar,164,externalcyl,external cylinder,boolean, ,true,switch.solar_external_cylinder,switch.solar_externalcyl,8,0,1,40,1 -SM200/MS200,solar,164,thermaldisinfect,thermal disinfection,boolean, ,true,switch.solar_thermal_disinfection,switch.solar_thermaldisinfect,8,0,1,41,1 -SM200/MS200,solar,164,heatmetering,heatmetering,boolean, ,true,switch.solar_heatmetering,switch.solar_heatmetering,8,0,1,42,1 -SM200/MS200,solar,164,activated,activated,boolean, ,true,switch.solar_activated,switch.solar_activated,8,0,1,43,1 -SM200/MS200,solar,164,solarpumpmode,solar pump mode,enum [constant\|pwm\|analog], ,true,select.solar_solar_pump_mode,select.solar_solarpumpmode,8,0,1,44,1 -SM200/MS200,solar,164,solarpumpkick,solar pump kick,boolean, ,true,switch.solar_solar_pump_kick,switch.solar_solarpumpkick,8,0,1,45,1 -SM200/MS200,solar,164,plainwatermode,plain water mode,boolean, ,true,switch.solar_plain_water_mode,switch.solar_plainwatermode,8,0,1,46,1 -SM200/MS200,solar,164,doublematchflow,doublematchflow,boolean, ,true,switch.solar_doublematchflow,switch.solar_doublematchflow,8,0,1,47,1 -SM200/MS200,solar,164,pump2minmod,minimum pump 2 modulation,uint8 (>=0<=100),%,true,number.solar_minimum_pump_2_modulation,number.solar_pump2minmod,8,0,1,48,1 -SM200/MS200,solar,164,turnondiff2,pump 2 turn on difference,uint8 (>=0<=25),C,true,number.solar_pump_2_turn_on_difference,number.solar_turnondiff2,8,0,1/10,49,1 -SM200/MS200,solar,164,turnoffdiff2,pump 2 turn off difference,uint8 (>=0<=25),C,true,number.solar_pump_2_turn_off_difference,number.solar_turnoffdiff2,8,0,1/10,50,1 -SM200/MS200,solar,164,pump2kick,pump kick 2,boolean, ,true,switch.solar_pump_kick_2,switch.solar_pump2kick,8,0,1,51,1 -SM200/MS200,solar,164,climatezone,climate zone,uint8 (>=0<=254), ,true,number.solar_climate_zone,number.solar_climatezone,8,0,1,52,1 -SM200/MS200,solar,164,collector1area,collector 1 area,uint16 (>=0<=3199),m²,true,number.solar_collector_1_area,number.solar_collector1area,8,0,1/10,53,1 -SM200/MS200,solar,164,collector1type,collector 1 type,enum [flat\|vacuum], ,true,select.solar_collector_1_type,select.solar_collector1type,8,0,1,54,1 -SM200/MS200,solar,164,collector2area,collector 2 area,uint16 (>=0<=3199),m²,true,number.solar_collector_2_area,number.solar_collector2area,8,0,1/10,55,1 -SM200/MS200,solar,164,collector2type,collector 2 type,enum [flat\|vacuum], ,true,select.solar_collector_2_type,select.solar_collector2type,8,0,1,56,1 -SM200/MS200,solar,164,cylpriority,cylinder priority,enum [cyl 1\|cyl 2], ,true,select.solar_cylinder_priority,select.solar_cylpriority,8,0,1,57,1 -SM200/MS200,solar,164,heatcntflowtemp,heat counter flow temperature,uint16 (>=0<=3199),C,false,sensor.solar_heat_counter_flow_temperature,sensor.solar_heatcntflowtemp,8,0,1/10,58,1 -SM200/MS200,solar,164,heatcntrettemp,heat counter return temperature,uint16 (>=0<=3199),C,false,sensor.solar_heat_counter_return_temperature,sensor.solar_heatcntrettemp,8,0,1/10,59,1 -SM200/MS200,solar,164,heatcnt,heat counter impulses,uint8 (>=0<=254), ,false,sensor.solar_heat_counter_impulses,sensor.solar_heatcnt,8,0,1,60,1 -SM200/MS200,solar,164,swapflowtemp,swap flow temperature (TS14),uint16 (>=0<=3199),C,false,sensor.solar_swap_flow_temperature_(TS14),sensor.solar_swapflowtemp,8,0,1/10,61,1 -SM200/MS200,solar,164,swaprettemp,swap return temperature (TS15),uint16 (>=0<=3199),C,false,sensor.solar_swap_return_temperature_(TS15),sensor.solar_swaprettemp,8,0,1/10,62,1 +SM100, MS100,solar,163,collectortemp,collector temperature (TS1),int16 (>=-3199<=3199),C,false,sensor.solar_collector_temperature_(TS1),sensor.solar_collectortemp,8,0,1/10,0,1 +SM100, MS100,solar,163,cylbottomtemp,cylinder bottom temperature (TS2),int16 (>=-3199<=3199),C,false,sensor.solar_cylinder_bottom_temperature_(TS2),sensor.solar_cylbottomtemp,8,0,1/10,1,1 +SM100, MS100,solar,163,solarpump,pump (PS1),boolean, ,false,binary_sensor.solar_pump_(PS1),binary_sensor.solar_solarpump,8,0,1,2,1 +SM100, MS100,solar,163,pumpworktime,pump working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_working_time,sensor.solar_pumpworktime,8,0,1,3,2 +SM100, MS100,solar,163,cylmaxtemp,maximum cylinder temperature,uint8 (>=0<=254),C,true,number.solar_maximum_cylinder_temperature,number.solar_cylmaxtemp,8,0,1,5,1 +SM100, MS100,solar,163,collectorshutdown,collector shutdown,boolean, ,false,binary_sensor.solar_collector_shutdown,binary_sensor.solar_collectorshutdown,8,0,1,6,1 +SM100, MS100,solar,163,cylheated,cyl heated,boolean, ,false,binary_sensor.solar_cyl_heated,binary_sensor.solar_cylheated,8,0,1,7,1 +SM100, MS100,solar,163,solarpumpmod,pump modulation (PS1),uint8 (>=0<=100),%,false,sensor.solar_pump_modulation_(PS1),sensor.solar_solarpumpmod,8,0,1,8,1 +SM100, MS100,solar,163,pumpminmod,minimum pump modulation,uint8 (>=0<=100),%,true,number.solar_minimum_pump_modulation,number.solar_pumpminmod,8,0,5,9,1 +SM100, MS100,solar,163,turnondiff,pump turn on difference,uint8 (>=0<=25),C,true,number.solar_pump_turn_on_difference,number.solar_turnondiff,8,0,1/10,10,1 +SM100, MS100,solar,163,turnoffdiff,pump turn off difference,uint8 (>=0<=25),C,true,number.solar_pump_turn_off_difference,number.solar_turnoffdiff,8,0,1/10,11,1 +SM100, MS100,solar,163,collector2temp,collector 2 temperature (TS7),int16 (>=-3199<=3199),C,false,sensor.solar_collector_2_temperature_(TS7),sensor.solar_collector2temp,8,0,1/10,20,1 +SM100, MS100,solar,163,cylmiddletemp,cylinder middle temperature (TS3),int16 (>=-3199<=3199),C,false,sensor.solar_cylinder_middle_temperature_(TS3),sensor.solar_cylmiddletemp,8,0,1/10,17,1 +SM100, MS100,solar,163,retheatassist,return temperature heat assistance (TS4),int16 (>=-3199<=3199),C,false,sensor.solar_return_temperature_heat_assistance_(TS4),sensor.solar_retheatassist,8,0,1/10,18,1 +SM100, MS100,solar,163,heatassistvalve,heat assistance valve (M1),boolean, ,false,binary_sensor.solar_heat_assistance_valve_(M1),binary_sensor.solar_heatassistvalve,8,0,1,19,1 +SM100, MS100,solar,163,heatassistpower,heat assistance valve power (M1),uint8 (>=0<=100),%,false,sensor.solar_heat_assistance_valve_power_(M1),sensor.solar_heatassistpower,8,0,1,21,1 +SM100, MS100,solar,163,solarpump2,pump 2 (PS4),boolean, ,false,binary_sensor.solar_pump_2_(PS4),binary_sensor.solar_solarpump2,8,0,1,22,1 +SM100, MS100,solar,163,solarpump2mod,pump 2 modulation (PS4),uint8 (>=0<=100),%,false,sensor.solar_pump_2_modulation_(PS4),sensor.solar_solarpump2mod,8,0,1,23,1 +SM100, MS100,solar,163,cyl2bottomtemp,second cylinder bottom temperature (TS5),int16 (>=-3199<=3199),C,false,sensor.solar_second_cylinder_bottom_temperature_(TS5),sensor.solar_cyl2bottomtemp,8,0,1/10,24,1 +SM100, MS100,solar,163,heatexchangertemp,heat exchanger temperature (TS6),int16 (>=-3199<=3199),C,false,sensor.solar_heat_exchanger_temperature_(TS6),sensor.solar_heatexchangertemp,8,0,1/10,25,1 +SM100, MS100,solar,163,cylpumpmod,cylinder pump modulation (PS5),uint8 (>=0<=100),%,false,sensor.solar_cylinder_pump_modulation_(PS5),sensor.solar_cylpumpmod,8,0,1,26,1 +SM100, MS100,solar,163,valvestatus,valve status,boolean, ,false,binary_sensor.solar_valve_status,binary_sensor.solar_valvestatus,8,0,1,27,1 +SM100, MS100,solar,163,vs1status,valve status VS1,boolean, ,false,binary_sensor.solar_valve_status_VS1,binary_sensor.solar_vs1status,8,0,1,28,1 +SM100, MS100,solar,163,collectormaxtemp,maximum collector temperature,uint8 (>=0<=254),C,true,number.solar_maximum_collector_temperature,number.solar_collectormaxtemp,8,0,1,29,1 +SM100, MS100,solar,163,collectormintemp,minimum collector temperature,uint8 (>=0<=254),C,true,number.solar_minimum_collector_temperature,number.solar_collectormintemp,8,0,1,30,1 +SM100, MS100,solar,163,energylasthour,energy last hour,uint24 (>=0<=1677721),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour,8,0,1/10,13,2 +SM100, MS100,solar,163,energytoday,total energy today,uint24 (>=0<=16777213),Wh,false,sensor.solar_total_energy_today,sensor.solar_energytoday,8,0,1,31,2 +SM100, MS100,solar,163,energytotal,total energy,uint24 (>=0<=1677721),kWh,false,sensor.solar_total_energy,sensor.solar_energytotal,8,0,1/10,33,2 +SM100, MS100,solar,163,pump2worktime,pump 2 working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_2_working_time,sensor.solar_pump2worktime,8,0,1,35,2 +SM100, MS100,solar,163,m1worktime,differential control working time,time (>=0<=16777213),minutes,false,sensor.solar_differential_control_working_time,sensor.solar_m1worktime,8,0,1,37,2 +SM100, MS100,solar,163,heattransfersystem,heattransfer system,boolean, ,true,switch.solar_heattransfer_system,switch.solar_heattransfersystem,8,0,1,39,1 +SM100, MS100,solar,163,externalcyl,external cylinder,boolean, ,true,switch.solar_external_cylinder,switch.solar_externalcyl,8,0,1,40,1 +SM100, MS100,solar,163,thermaldisinfect,thermal disinfection,boolean, ,true,switch.solar_thermal_disinfection,switch.solar_thermaldisinfect,8,0,1,41,1 +SM100, MS100,solar,163,heatmetering,heatmetering,boolean, ,true,switch.solar_heatmetering,switch.solar_heatmetering,8,0,1,42,1 +SM100, MS100,solar,163,activated,activated,boolean, ,true,switch.solar_activated,switch.solar_activated,8,0,1,43,1 +SM100, MS100,solar,163,solarpumpmode,solar pump mode,enum [constant\|pwm\|analog], ,true,select.solar_solar_pump_mode,select.solar_solarpumpmode,8,0,1,44,1 +SM100, MS100,solar,163,solarpumpkick,solar pump kick,boolean, ,true,switch.solar_solar_pump_kick,switch.solar_solarpumpkick,8,0,1,45,1 +SM100, MS100,solar,163,plainwatermode,plain water mode,boolean, ,true,switch.solar_plain_water_mode,switch.solar_plainwatermode,8,0,1,46,1 +SM100, MS100,solar,163,doublematchflow,doublematchflow,boolean, ,true,switch.solar_doublematchflow,switch.solar_doublematchflow,8,0,1,47,1 +SM100, MS100,solar,163,pump2minmod,minimum pump 2 modulation,uint8 (>=0<=100),%,true,number.solar_minimum_pump_2_modulation,number.solar_pump2minmod,8,0,1,48,1 +SM100, MS100,solar,163,turnondiff2,pump 2 turn on difference,uint8 (>=0<=25),C,true,number.solar_pump_2_turn_on_difference,number.solar_turnondiff2,8,0,1/10,49,1 +SM100, MS100,solar,163,turnoffdiff2,pump 2 turn off difference,uint8 (>=0<=25),C,true,number.solar_pump_2_turn_off_difference,number.solar_turnoffdiff2,8,0,1/10,50,1 +SM100, MS100,solar,163,pump2kick,pump kick 2,boolean, ,true,switch.solar_pump_kick_2,switch.solar_pump2kick,8,0,1,51,1 +SM100, MS100,solar,163,climatezone,climate zone,uint8 (>=0<=254), ,true,number.solar_climate_zone,number.solar_climatezone,8,0,1,52,1 +SM100, MS100,solar,163,collector1area,collector 1 area,uint16 (>=0<=3199),m²,true,number.solar_collector_1_area,number.solar_collector1area,8,0,1/10,53,1 +SM100, MS100,solar,163,collector1type,collector 1 type,enum [flat\|vacuum], ,true,select.solar_collector_1_type,select.solar_collector1type,8,0,1,54,1 +SM100, MS100,solar,163,collector2area,collector 2 area,uint16 (>=0<=3199),m²,true,number.solar_collector_2_area,number.solar_collector2area,8,0,1/10,55,1 +SM100, MS100,solar,163,collector2type,collector 2 type,enum [flat\|vacuum], ,true,select.solar_collector_2_type,select.solar_collector2type,8,0,1,56,1 +SM100, MS100,solar,163,cylpriority,cylinder priority,enum [cyl 1\|cyl 2], ,true,select.solar_cylinder_priority,select.solar_cylpriority,8,0,1,57,1 +SM100, MS100,solar,163,heatcntflowtemp,heat counter flow temperature,uint16 (>=0<=3199),C,false,sensor.solar_heat_counter_flow_temperature,sensor.solar_heatcntflowtemp,8,0,1/10,58,1 +SM100, MS100,solar,163,heatcntrettemp,heat counter return temperature,uint16 (>=0<=3199),C,false,sensor.solar_heat_counter_return_temperature,sensor.solar_heatcntrettemp,8,0,1/10,59,1 +SM100, MS100,solar,163,heatcnt,heat counter impulses,uint8 (>=0<=254), ,false,sensor.solar_heat_counter_impulses,sensor.solar_heatcnt,8,0,1,60,1 +SM100, MS100,solar,163,swapflowtemp,swap flow temperature (TS14),uint16 (>=0<=3199),C,false,sensor.solar_swap_flow_temperature_(TS14),sensor.solar_swapflowtemp,8,0,1/10,61,1 +SM100, MS100,solar,163,swaprettemp,swap return temperature (TS15),uint16 (>=0<=3199),C,false,sensor.solar_swap_return_temperature_(TS15),sensor.solar_swaprettemp,8,0,1/10,62,1 +SM200, MS200,solar,164,collectortemp,collector temperature (TS1),int16 (>=-3199<=3199),C,false,sensor.solar_collector_temperature_(TS1),sensor.solar_collectortemp,8,0,1/10,0,1 +SM200, MS200,solar,164,cylbottomtemp,cylinder bottom temperature (TS2),int16 (>=-3199<=3199),C,false,sensor.solar_cylinder_bottom_temperature_(TS2),sensor.solar_cylbottomtemp,8,0,1/10,1,1 +SM200, MS200,solar,164,solarpump,pump (PS1),boolean, ,false,binary_sensor.solar_pump_(PS1),binary_sensor.solar_solarpump,8,0,1,2,1 +SM200, MS200,solar,164,pumpworktime,pump working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_working_time,sensor.solar_pumpworktime,8,0,1,3,2 +SM200, MS200,solar,164,cylmaxtemp,maximum cylinder temperature,uint8 (>=0<=254),C,true,number.solar_maximum_cylinder_temperature,number.solar_cylmaxtemp,8,0,1,5,1 +SM200, MS200,solar,164,collectorshutdown,collector shutdown,boolean, ,false,binary_sensor.solar_collector_shutdown,binary_sensor.solar_collectorshutdown,8,0,1,6,1 +SM200, MS200,solar,164,cylheated,cyl heated,boolean, ,false,binary_sensor.solar_cyl_heated,binary_sensor.solar_cylheated,8,0,1,7,1 +SM200, MS200,solar,164,solarpumpmod,pump modulation (PS1),uint8 (>=0<=100),%,false,sensor.solar_pump_modulation_(PS1),sensor.solar_solarpumpmod,8,0,1,8,1 +SM200, MS200,solar,164,pumpminmod,minimum pump modulation,uint8 (>=0<=100),%,true,number.solar_minimum_pump_modulation,number.solar_pumpminmod,8,0,5,9,1 +SM200, MS200,solar,164,turnondiff,pump turn on difference,uint8 (>=0<=25),C,true,number.solar_pump_turn_on_difference,number.solar_turnondiff,8,0,1/10,10,1 +SM200, MS200,solar,164,turnoffdiff,pump turn off difference,uint8 (>=0<=25),C,true,number.solar_pump_turn_off_difference,number.solar_turnoffdiff,8,0,1/10,11,1 +SM200, MS200,solar,164,collector2temp,collector 2 temperature (TS7),int16 (>=-3199<=3199),C,false,sensor.solar_collector_2_temperature_(TS7),sensor.solar_collector2temp,8,0,1/10,20,1 +SM200, MS200,solar,164,cylmiddletemp,cylinder middle temperature (TS3),int16 (>=-3199<=3199),C,false,sensor.solar_cylinder_middle_temperature_(TS3),sensor.solar_cylmiddletemp,8,0,1/10,17,1 +SM200, MS200,solar,164,retheatassist,return temperature heat assistance (TS4),int16 (>=-3199<=3199),C,false,sensor.solar_return_temperature_heat_assistance_(TS4),sensor.solar_retheatassist,8,0,1/10,18,1 +SM200, MS200,solar,164,heatassistvalve,heat assistance valve (M1),boolean, ,false,binary_sensor.solar_heat_assistance_valve_(M1),binary_sensor.solar_heatassistvalve,8,0,1,19,1 +SM200, MS200,solar,164,heatassistpower,heat assistance valve power (M1),uint8 (>=0<=100),%,false,sensor.solar_heat_assistance_valve_power_(M1),sensor.solar_heatassistpower,8,0,1,21,1 +SM200, MS200,solar,164,solarpump2,pump 2 (PS4),boolean, ,false,binary_sensor.solar_pump_2_(PS4),binary_sensor.solar_solarpump2,8,0,1,22,1 +SM200, MS200,solar,164,solarpump2mod,pump 2 modulation (PS4),uint8 (>=0<=100),%,false,sensor.solar_pump_2_modulation_(PS4),sensor.solar_solarpump2mod,8,0,1,23,1 +SM200, MS200,solar,164,cyl2bottomtemp,second cylinder bottom temperature (TS5),int16 (>=-3199<=3199),C,false,sensor.solar_second_cylinder_bottom_temperature_(TS5),sensor.solar_cyl2bottomtemp,8,0,1/10,24,1 +SM200, MS200,solar,164,heatexchangertemp,heat exchanger temperature (TS6),int16 (>=-3199<=3199),C,false,sensor.solar_heat_exchanger_temperature_(TS6),sensor.solar_heatexchangertemp,8,0,1/10,25,1 +SM200, MS200,solar,164,cylpumpmod,cylinder pump modulation (PS5),uint8 (>=0<=100),%,false,sensor.solar_cylinder_pump_modulation_(PS5),sensor.solar_cylpumpmod,8,0,1,26,1 +SM200, MS200,solar,164,valvestatus,valve status,boolean, ,false,binary_sensor.solar_valve_status,binary_sensor.solar_valvestatus,8,0,1,27,1 +SM200, MS200,solar,164,vs1status,valve status VS1,boolean, ,false,binary_sensor.solar_valve_status_VS1,binary_sensor.solar_vs1status,8,0,1,28,1 +SM200, MS200,solar,164,collectormaxtemp,maximum collector temperature,uint8 (>=0<=254),C,true,number.solar_maximum_collector_temperature,number.solar_collectormaxtemp,8,0,1,29,1 +SM200, MS200,solar,164,collectormintemp,minimum collector temperature,uint8 (>=0<=254),C,true,number.solar_minimum_collector_temperature,number.solar_collectormintemp,8,0,1,30,1 +SM200, MS200,solar,164,energylasthour,energy last hour,uint24 (>=0<=1677721),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour,8,0,1/10,13,2 +SM200, MS200,solar,164,energytoday,total energy today,uint24 (>=0<=16777213),Wh,false,sensor.solar_total_energy_today,sensor.solar_energytoday,8,0,1,31,2 +SM200, MS200,solar,164,energytotal,total energy,uint24 (>=0<=1677721),kWh,false,sensor.solar_total_energy,sensor.solar_energytotal,8,0,1/10,33,2 +SM200, MS200,solar,164,pump2worktime,pump 2 working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_2_working_time,sensor.solar_pump2worktime,8,0,1,35,2 +SM200, MS200,solar,164,m1worktime,differential control working time,time (>=0<=16777213),minutes,false,sensor.solar_differential_control_working_time,sensor.solar_m1worktime,8,0,1,37,2 +SM200, MS200,solar,164,heattransfersystem,heattransfer system,boolean, ,true,switch.solar_heattransfer_system,switch.solar_heattransfersystem,8,0,1,39,1 +SM200, MS200,solar,164,externalcyl,external cylinder,boolean, ,true,switch.solar_external_cylinder,switch.solar_externalcyl,8,0,1,40,1 +SM200, MS200,solar,164,thermaldisinfect,thermal disinfection,boolean, ,true,switch.solar_thermal_disinfection,switch.solar_thermaldisinfect,8,0,1,41,1 +SM200, MS200,solar,164,heatmetering,heatmetering,boolean, ,true,switch.solar_heatmetering,switch.solar_heatmetering,8,0,1,42,1 +SM200, MS200,solar,164,activated,activated,boolean, ,true,switch.solar_activated,switch.solar_activated,8,0,1,43,1 +SM200, MS200,solar,164,solarpumpmode,solar pump mode,enum [constant\|pwm\|analog], ,true,select.solar_solar_pump_mode,select.solar_solarpumpmode,8,0,1,44,1 +SM200, MS200,solar,164,solarpumpkick,solar pump kick,boolean, ,true,switch.solar_solar_pump_kick,switch.solar_solarpumpkick,8,0,1,45,1 +SM200, MS200,solar,164,plainwatermode,plain water mode,boolean, ,true,switch.solar_plain_water_mode,switch.solar_plainwatermode,8,0,1,46,1 +SM200, MS200,solar,164,doublematchflow,doublematchflow,boolean, ,true,switch.solar_doublematchflow,switch.solar_doublematchflow,8,0,1,47,1 +SM200, MS200,solar,164,pump2minmod,minimum pump 2 modulation,uint8 (>=0<=100),%,true,number.solar_minimum_pump_2_modulation,number.solar_pump2minmod,8,0,1,48,1 +SM200, MS200,solar,164,turnondiff2,pump 2 turn on difference,uint8 (>=0<=25),C,true,number.solar_pump_2_turn_on_difference,number.solar_turnondiff2,8,0,1/10,49,1 +SM200, MS200,solar,164,turnoffdiff2,pump 2 turn off difference,uint8 (>=0<=25),C,true,number.solar_pump_2_turn_off_difference,number.solar_turnoffdiff2,8,0,1/10,50,1 +SM200, MS200,solar,164,pump2kick,pump kick 2,boolean, ,true,switch.solar_pump_kick_2,switch.solar_pump2kick,8,0,1,51,1 +SM200, MS200,solar,164,climatezone,climate zone,uint8 (>=0<=254), ,true,number.solar_climate_zone,number.solar_climatezone,8,0,1,52,1 +SM200, MS200,solar,164,collector1area,collector 1 area,uint16 (>=0<=3199),m²,true,number.solar_collector_1_area,number.solar_collector1area,8,0,1/10,53,1 +SM200, MS200,solar,164,collector1type,collector 1 type,enum [flat\|vacuum], ,true,select.solar_collector_1_type,select.solar_collector1type,8,0,1,54,1 +SM200, MS200,solar,164,collector2area,collector 2 area,uint16 (>=0<=3199),m²,true,number.solar_collector_2_area,number.solar_collector2area,8,0,1/10,55,1 +SM200, MS200,solar,164,collector2type,collector 2 type,enum [flat\|vacuum], ,true,select.solar_collector_2_type,select.solar_collector2type,8,0,1,56,1 +SM200, MS200,solar,164,cylpriority,cylinder priority,enum [cyl 1\|cyl 2], ,true,select.solar_cylinder_priority,select.solar_cylpriority,8,0,1,57,1 +SM200, MS200,solar,164,heatcntflowtemp,heat counter flow temperature,uint16 (>=0<=3199),C,false,sensor.solar_heat_counter_flow_temperature,sensor.solar_heatcntflowtemp,8,0,1/10,58,1 +SM200, MS200,solar,164,heatcntrettemp,heat counter return temperature,uint16 (>=0<=3199),C,false,sensor.solar_heat_counter_return_temperature,sensor.solar_heatcntrettemp,8,0,1/10,59,1 +SM200, MS200,solar,164,heatcnt,heat counter impulses,uint8 (>=0<=254), ,false,sensor.solar_heat_counter_impulses,sensor.solar_heatcnt,8,0,1,60,1 +SM200, MS200,solar,164,swapflowtemp,swap flow temperature (TS14),uint16 (>=0<=3199),C,false,sensor.solar_swap_flow_temperature_(TS14),sensor.solar_swapflowtemp,8,0,1/10,61,1 +SM200, MS200,solar,164,swaprettemp,swap return temperature (TS15),uint16 (>=0<=3199),C,false,sensor.solar_swap_return_temperature_(TS15),sensor.solar_swaprettemp,8,0,1/10,62,1 HP Module,heatpump,252,airhumidity,relative air humidity,uint8 (>=0<=100),%,false,sensor.heatpump_relative_air_humidity,sensor.heatpump_airhumidity,9,0,1,0,1 HP Module,heatpump,252,dewtemperature,dew point temperature,uint8 (>=0<=254),C,false,sensor.heatpump_dew_point_temperature,sensor.heatpump_dewtemperature,9,0,1,1,1 HP Module,heatpump,252,curflowtemp,current flow temperature,int16 (>=-3199<=3199),C,false,sensor.heatpump_current_flow_temperature,sensor.heatpump_curflowtemp,9,0,1/10,2,1 @@ -5037,16 +5068,16 @@ WM10,switch,71,status,status,int8 (>=-126<=126), ,false,sensor.switch_status,sen Rego 3000,controller,240,datetime,date/time,string, ,false,sensor.controller_date/time,sensor.controller_datetime,12,0,1,0,13 EM10,alert,74,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.alert_set_flow_temperature,sensor.alert_setflowtemp,14,0,1,0,1 EM10,alert,74,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.alert_burner_set_power,sensor.alert_setburnpow,14,0,1,1,1 -EM10/EM100,extension,243,flowtempvf,flow temperature in header (T0/Vf),int16 (>=-3199<=3199),C,false,sensor.extension_flow_temperature_in_header_(T0/Vf),sensor.extension_flowtempvf,15,0,1/10,0,1 -EM10/EM100,extension,243,input,input,uint8 (>=0<=25),V,false,sensor.extension_input,sensor.extension_input,15,0,1/10,1,1 -EM10/EM100,extension,243,outpow,output IO1,uint8 (>=0<=100),%,false,sensor.extension_output_IO1,sensor.extension_outpow,15,0,1,2,1 -EM10/EM100,extension,243,setpower,request power,uint8 (>=0<=100),%,false,sensor.extension_request_power,sensor.extension_setpower,15,0,1,3,1 -EM10/EM100,extension,243,setpoint,set temp.,uint8 (>=0<=254),C,false,sensor.extension_set_temp.,sensor.extension_setpoint,15,0,1,4,1 -EM10/EM100,extension,243,minv,min volt.,uint8 (>=0<=25),V,true,number.extension_min_volt.,number.extension_minv,15,0,1/10,5,1 -EM10/EM100,extension,243,maxv,max volt.,uint8 (>=0<=25),V,true,number.extension_max_volt.,number.extension_maxv,15,0,1/10,6,1 -EM10/EM100,extension,243,mint,min temp.,uint8 (>=0<=254),C,true,number.extension_min_temp.,number.extension_mint,15,0,1,7,1 -EM10/EM100,extension,243,maxt,max temp.,uint8 (>=0<=254),C,true,number.extension_max_temp.,number.extension_maxt,15,0,1,8,1 -EM10/EM100,extension,243,mode,operating mode,uint8 (>=0<=254), ,false,sensor.extension_operating_mode,sensor.extension_mode,15,0,1,9,1 +EM10, EM100,extension,243,flowtempvf,flow temperature in header (T0/Vf),int16 (>=-3199<=3199),C,false,sensor.extension_flow_temperature_in_header_(T0/Vf),sensor.extension_flowtempvf,15,0,1/10,0,1 +EM10, EM100,extension,243,input,input,uint8 (>=0<=25),V,false,sensor.extension_input,sensor.extension_input,15,0,1/10,1,1 +EM10, EM100,extension,243,outpow,output IO1,uint8 (>=0<=100),%,false,sensor.extension_output_IO1,sensor.extension_outpow,15,0,1,2,1 +EM10, EM100,extension,243,setpower,request power,uint8 (>=0<=100),%,false,sensor.extension_request_power,sensor.extension_setpower,15,0,1,3,1 +EM10, EM100,extension,243,setpoint,set temp.,uint8 (>=0<=254),C,false,sensor.extension_set_temp.,sensor.extension_setpoint,15,0,1,4,1 +EM10, EM100,extension,243,minv,min volt.,uint8 (>=0<=25),V,true,number.extension_min_volt.,number.extension_minv,15,0,1/10,5,1 +EM10, EM100,extension,243,maxv,max volt.,uint8 (>=0<=25),V,true,number.extension_max_volt.,number.extension_maxv,15,0,1/10,6,1 +EM10, EM100,extension,243,mint,min temp.,uint8 (>=0<=254),C,true,number.extension_min_temp.,number.extension_mint,15,0,1,7,1 +EM10, EM100,extension,243,maxt,max temp.,uint8 (>=0<=254),C,true,number.extension_max_temp.,number.extension_maxt,15,0,1,8,1 +EM10, EM100,extension,243,mode,operating mode,uint8 (>=0<=254), ,false,sensor.extension_operating_mode,sensor.extension_mode,15,0,1,9,1 T1RF,extension,220,flowtempvf,flow temperature in header (T0/Vf),int16 (>=-3199<=3199),C,false,sensor.extension_flow_temperature_in_header_(T0/Vf),sensor.extension_flowtempvf,15,0,1/10,0,1 T1RF,extension,220,input,input,uint8 (>=0<=25),V,false,sensor.extension_input,sensor.extension_input,15,0,1/10,1,1 T1RF,extension,220,outpow,output IO1,uint8 (>=0<=100),%,false,sensor.extension_output_IO1,sensor.extension_outpow,15,0,1,2,1 diff --git a/dump_telegrams.csv b/dump_telegrams.csv index 3da684602..07a0404a3 100644 --- a/dump_telegrams.csv +++ b/dump_telegrams.csv @@ -107,7 +107,7 @@ telegram_type_id,name,is_fetched 0x02A2,RC300Curves, 0x02A5,RC300Monitor, 0x02A6,RC300Monitor, -0x02A7,CRFMonitor, +0x02A7,RC300Monitor, 0x02A8,RC300Monitor, 0x02A9,RC300Monitor, 0x02AA,RC300Monitor, diff --git a/scripts/generate-modbus-register-doc.py b/scripts/generate-modbus-register-doc.py index 5d735542a..b2c960fd5 100644 --- a/scripts/generate-modbus-register-doc.py +++ b/scripts/generate-modbus-register-doc.py @@ -1,6 +1,5 @@ import fileinput import csv -import sys from itertools import groupby # static data diff --git a/scripts/generate-modbus-register-doc.sh b/scripts/generate-modbus-register-doc.sh index 6f1142da9..f034f7c65 100644 --- a/scripts/generate-modbus-register-doc.sh +++ b/scripts/generate-modbus-register-doc.sh @@ -3,4 +3,3 @@ make clean make ARGS=-DEMSESP_STANDALONE echo "test entity_dump" | ./emsesp | python3 ./scripts/strip_csv.py | python3 ./scripts/generate-modbus-register-doc.py - diff --git a/scripts/update_modbus_registers.sh b/scripts/update_modbus_registers.sh index 21b4aed03..62e0da97c 100644 --- a/scripts/update_modbus_registers.sh +++ b/scripts/update_modbus_registers.sh @@ -3,28 +3,28 @@ # Update modbus parameters from entity definitions. # This script generates c++ code for the modbus parameter definitions. # -# Run this script from the EMS-ESP32 root directory with the command `sh ./scripts/update_modbus_registers.sh`. +# Run this script from the EMS-ESP32 root directory with the command `bash ./scripts/update_modbus_registers.sh`. while [[ $# -gt 0 ]]; do case $1 in - --reset) - RESET=YES - shift - ;; - --force) - FORCE=YES - shift - ;; - *|-*|--*) - echo "Unknown option $1" - exit 1 - ;; + --reset) + RESET=YES + shift + ;; + --force) + FORCE=YES + shift + ;; + * | -* | --*) + echo "Unknown option $1" + exit 1 + ;; esac done if [ "$RESET" = "YES" ]; then if [ "$FORCE" != "YES" ]; then - read -p "Are you sure you want to reset all modbus entity parameters, potentially generating new register mappings? WARNING: This might introduce breaking changes for end users. [yes/no] " CONFIRMATION + read -p "Are you sure you want to reset all modbus entity parameters, potentially generating new register mappings? WARNING: This might introduce breaking changes for end users. [yes/no] " CONFIRMATION if [ "$CONFIRMATION" != "yes" ]; then echo "Aborted." exit 1 @@ -60,6 +60,5 @@ fi make clean make ARGS=-DEMSESP_STANDALONE -echo "test entity_dump" | ./emsesp | python3 ./scripts/strip_csv.py | python3 ./scripts/update_modbus_registers.py > ./src/modbus_entity_parameters.hpp +echo "test entity_dump" | ./emsesp | python3 ./scripts/strip_csv.py | python3 ./scripts/update_modbus_registers.py >./src/modbus_entity_parameters.hpp echo "Modbus entity parameters written to ./src/modbus_entity_parameters.hpp." -