MM10 mixer added, changed WWDesired to WWDesinfection, added boier exhaust temperature

This commit is contained in:
MichaelDvP
2019-12-30 13:35:23 +01:00
parent f27088c035
commit a22e64a8ca
4 changed files with 43 additions and 9 deletions

View File

@@ -296,7 +296,7 @@ void showInfo() {
} }
_renderIntValue("Warm Water selected temperature", "C", EMS_Boiler.wWSelTemp); _renderIntValue("Warm Water selected temperature", "C", EMS_Boiler.wWSelTemp);
_renderIntValue("Warm Water desired temperature", "C", EMS_Boiler.wWDesiredTemp); _renderIntValue("Warm Water desinfection temperature", "C", EMS_Boiler.wWDesinfectTemp);
// UBAMonitorWWMessage // UBAMonitorWWMessage
_renderUShortValue("Warm Water current temperature", "C", EMS_Boiler.wWCurTmp); _renderUShortValue("Warm Water current temperature", "C", EMS_Boiler.wWCurTmp);
@@ -339,6 +339,7 @@ void showInfo() {
_renderShortValue("Outside temperature", "C", EMS_Boiler.extTemp); _renderShortValue("Outside temperature", "C", EMS_Boiler.extTemp);
} }
_renderUShortValue("Boiler temperature", "C", EMS_Boiler.boilTemp); _renderUShortValue("Boiler temperature", "C", EMS_Boiler.boilTemp);
_renderUShortValue("Exhaust temperature", "C", EMS_Boiler.exhaustTemp);
_renderIntValue("Pump modulation", "%", EMS_Boiler.pumpMod); _renderIntValue("Pump modulation", "%", EMS_Boiler.pumpMod);
_renderLongValue("Burner # starts", "times", EMS_Boiler.burnStarts); _renderLongValue("Burner # starts", "times", EMS_Boiler.burnStarts);
if (EMS_Boiler.burnWorkMin != EMS_VALUE_LONG_NOTSET) { if (EMS_Boiler.burnWorkMin != EMS_VALUE_LONG_NOTSET) {
@@ -475,8 +476,12 @@ void showInfo() {
if (EMS_Mixing.hc[hc_num - 1].active) { if (EMS_Mixing.hc[hc_num - 1].active) {
myDebug_P(PSTR(" Mixing Circuit %d"), hc_num); myDebug_P(PSTR(" Mixing Circuit %d"), hc_num);
_renderUShortValue(" Current flow temperature", "C", EMS_Mixing.hc[hc_num - 1].flowTemp); _renderUShortValue(" Current flow temperature", "C", EMS_Mixing.hc[hc_num - 1].flowTemp);
if (EMS_Mixing.hc[hc_num - 1].flowSetTemp != EMS_VALUE_INT_NOTSET)
_renderIntValue(" Setpoint flow temperature", "C", EMS_Mixing.hc[hc_num - 1].flowSetTemp);
_renderIntValue(" Current pump modulation", "%", EMS_Mixing.hc[hc_num - 1].pumpMod); _renderIntValue(" Current pump modulation", "%", EMS_Mixing.hc[hc_num - 1].pumpMod);
_renderIntValue(" Current valve status", "%", EMS_Mixing.hc[hc_num - 1].valveStatus); if (EMS_Mixing.hc[hc_num - 1].valveStatus != EMS_VALUE_INT_NOTSET)
_renderIntValue(" Current valve status", "", EMS_Mixing.hc[hc_num - 1].valveStatus);
} }
} }
} }
@@ -561,8 +566,8 @@ void publishEMSValues(bool force) {
if (EMS_Boiler.wWSelTemp != EMS_VALUE_INT_NOTSET) if (EMS_Boiler.wWSelTemp != EMS_VALUE_INT_NOTSET)
rootBoiler["wWSelTemp"] = EMS_Boiler.wWSelTemp; rootBoiler["wWSelTemp"] = EMS_Boiler.wWSelTemp;
if (EMS_Boiler.wWDesiredTemp != EMS_VALUE_INT_NOTSET) if (EMS_Boiler.wWDesinfectTemp != EMS_VALUE_INT_NOTSET)
rootBoiler["wWDesiredTemp"] = EMS_Boiler.wWDesiredTemp; rootBoiler["wWDesinfectionTemp"] = EMS_Boiler.wWDesinfectTemp;
if (EMS_Boiler.selFlowTemp != EMS_VALUE_INT_NOTSET) if (EMS_Boiler.selFlowTemp != EMS_VALUE_INT_NOTSET)
rootBoiler["selFlowTemp"] = EMS_Boiler.selFlowTemp; rootBoiler["selFlowTemp"] = EMS_Boiler.selFlowTemp;
if (EMS_Boiler.selBurnPow != EMS_VALUE_INT_NOTSET) if (EMS_Boiler.selBurnPow != EMS_VALUE_INT_NOTSET)
@@ -590,7 +595,8 @@ void publishEMSValues(bool force) {
rootBoiler["sysPress"] = (float)EMS_Boiler.sysPress / 10; rootBoiler["sysPress"] = (float)EMS_Boiler.sysPress / 10;
if (EMS_Boiler.boilTemp != EMS_VALUE_USHORT_NOTSET) if (EMS_Boiler.boilTemp != EMS_VALUE_USHORT_NOTSET)
rootBoiler["boilTemp"] = (float)EMS_Boiler.boilTemp / 10; rootBoiler["boilTemp"] = (float)EMS_Boiler.boilTemp / 10;
if (EMS_Boiler.exhaustTemp != EMS_VALUE_USHORT_NOTSET)
rootBoiler["exhaustTemp"] = (float)EMS_Boiler.exhaustTemp / 10;
if (EMS_Boiler.wWActivated != EMS_VALUE_BOOL_NOTSET) if (EMS_Boiler.wWActivated != EMS_VALUE_BOOL_NOTSET)
rootBoiler["wWActivated"] = _bool_to_char(s, EMS_Boiler.wWActivated); rootBoiler["wWActivated"] = _bool_to_char(s, EMS_Boiler.wWActivated);
@@ -750,6 +756,8 @@ void publishEMSValues(bool force) {
if (mixing->flowTemp != EMS_VALUE_SHORT_NOTSET) if (mixing->flowTemp != EMS_VALUE_SHORT_NOTSET)
dataMixing["flowTemp"] = (float)mixing->flowTemp / 10; dataMixing["flowTemp"] = (float)mixing->flowTemp / 10;
if (mixing->flowSetTemp != EMS_VALUE_INT_NOTSET)
dataMixing["setflowTemp"] = mixing->flowSetTemp;
if (mixing->pumpMod != EMS_VALUE_INT_NOTSET) if (mixing->pumpMod != EMS_VALUE_INT_NOTSET)
dataMixing["pumpMod"] = mixing->pumpMod; dataMixing["pumpMod"] = mixing->pumpMod;
if (mixing->valveStatus != EMS_VALUE_INT_NOTSET) if (mixing->valveStatus != EMS_VALUE_INT_NOTSET)

View File

@@ -121,13 +121,14 @@ void ems_init() {
EMS_Mixing.hc[i].flowTemp = EMS_VALUE_SHORT_NOTSET; EMS_Mixing.hc[i].flowTemp = EMS_VALUE_SHORT_NOTSET;
EMS_Mixing.hc[i].pumpMod = EMS_VALUE_INT_NOTSET; EMS_Mixing.hc[i].pumpMod = EMS_VALUE_INT_NOTSET;
EMS_Mixing.hc[i].valveStatus = EMS_VALUE_INT_NOTSET; EMS_Mixing.hc[i].valveStatus = EMS_VALUE_INT_NOTSET;
EMS_Mixing.hc[i].flowSetTemp = EMS_VALUE_INT_NOTSET;
} }
// UBAParameterWW // UBAParameterWW
EMS_Boiler.wWActivated = EMS_VALUE_BOOL_NOTSET; // Warm Water activated EMS_Boiler.wWActivated = EMS_VALUE_BOOL_NOTSET; // Warm Water activated
EMS_Boiler.wWSelTemp = EMS_VALUE_INT_NOTSET; // Warm Water selected temperature EMS_Boiler.wWSelTemp = EMS_VALUE_INT_NOTSET; // Warm Water selected temperature
EMS_Boiler.wWCircPump = EMS_VALUE_BOOL_NOTSET; // Warm Water circulation pump available EMS_Boiler.wWCircPump = EMS_VALUE_BOOL_NOTSET; // Warm Water circulation pump available
EMS_Boiler.wWDesiredTemp = EMS_VALUE_INT_NOTSET; // Warm Water desired temperature to prevent infection EMS_Boiler.wWDesinfectTemp = EMS_VALUE_INT_NOTSET; // Warm Water desinfection temperature to prevent infection
EMS_Boiler.wWComfort = EMS_VALUE_INT_NOTSET; // WW comfort mode EMS_Boiler.wWComfort = EMS_VALUE_INT_NOTSET; // WW comfort mode
// UBAMonitorFast // UBAMonitorFast
@@ -150,6 +151,7 @@ void ems_init() {
// UBAMonitorSlow // UBAMonitorSlow
EMS_Boiler.extTemp = EMS_VALUE_SHORT_NOTSET; // Outside temperature EMS_Boiler.extTemp = EMS_VALUE_SHORT_NOTSET; // Outside temperature
EMS_Boiler.boilTemp = EMS_VALUE_USHORT_NOTSET; // Boiler temperature EMS_Boiler.boilTemp = EMS_VALUE_USHORT_NOTSET; // Boiler temperature
EMS_Boiler.exhaustTemp = EMS_VALUE_USHORT_NOTSET; // Exhaust temperature
EMS_Boiler.pumpMod = EMS_VALUE_INT_NOTSET; // Pump modulation % EMS_Boiler.pumpMod = EMS_VALUE_INT_NOTSET; // Pump modulation %
EMS_Boiler.burnStarts = EMS_VALUE_LONG_NOTSET; // # burner restarts EMS_Boiler.burnStarts = EMS_VALUE_LONG_NOTSET; // # burner restarts
EMS_Boiler.burnWorkMin = EMS_VALUE_LONG_NOTSET; // Total burner operating time EMS_Boiler.burnWorkMin = EMS_VALUE_LONG_NOTSET; // Total burner operating time
@@ -951,7 +953,7 @@ void _process_UBAParameterWW(_EMS_RxTelegram * EMS_RxTelegram) {
_setValue(EMS_RxTelegram, &EMS_Boiler.wWActivated, 1); // 0xFF means on _setValue(EMS_RxTelegram, &EMS_Boiler.wWActivated, 1); // 0xFF means on
_setValue(EMS_RxTelegram, &EMS_Boiler.wWCircPump, 6); // 0xFF means on _setValue(EMS_RxTelegram, &EMS_Boiler.wWCircPump, 6); // 0xFF means on
_setValue(EMS_RxTelegram, &EMS_Boiler.wWSelTemp, 2); _setValue(EMS_RxTelegram, &EMS_Boiler.wWSelTemp, 2);
_setValue(EMS_RxTelegram, &EMS_Boiler.wWDesiredTemp, 8); _setValue(EMS_RxTelegram, &EMS_Boiler.wWDesinfectTemp, 8);
_setValue(EMS_RxTelegram, &EMS_Boiler.wWComfort, EMS_OFFSET_UBAParameterWW_wwComfort); _setValue(EMS_RxTelegram, &EMS_Boiler.wWComfort, EMS_OFFSET_UBAParameterWW_wwComfort);
} }
@@ -1083,6 +1085,7 @@ void _process_UBAMonitorFast2(_EMS_RxTelegram * EMS_RxTelegram) {
void _process_UBAMonitorSlow(_EMS_RxTelegram * EMS_RxTelegram) { void _process_UBAMonitorSlow(_EMS_RxTelegram * EMS_RxTelegram) {
_setValue(EMS_RxTelegram, &EMS_Boiler.extTemp, 0); _setValue(EMS_RxTelegram, &EMS_Boiler.extTemp, 0);
_setValue(EMS_RxTelegram, &EMS_Boiler.boilTemp, 2); _setValue(EMS_RxTelegram, &EMS_Boiler.boilTemp, 2);
_setValue(EMS_RxTelegram, &EMS_Boiler.exhaustTemp, 4);
_setValue(EMS_RxTelegram, &EMS_Boiler.switchTemp, 25); // only if there is a mixer _setValue(EMS_RxTelegram, &EMS_Boiler.switchTemp, 25); // only if there is a mixer
_setValue(EMS_RxTelegram, &EMS_Boiler.pumpMod, 9); _setValue(EMS_RxTelegram, &EMS_Boiler.pumpMod, 9);
_setValue(EMS_RxTelegram, &EMS_Boiler.burnStarts, 10); _setValue(EMS_RxTelegram, &EMS_Boiler.burnStarts, 10);
@@ -1226,6 +1229,19 @@ void _process_MMPLUSStatusMessage(_EMS_RxTelegram * EMS_RxTelegram) {
_setValue(EMS_RxTelegram, &EMS_Mixing.hc[hc].valveStatus, EMS_OFFSET_MMPLUSStatusMessage_valve_status); _setValue(EMS_RxTelegram, &EMS_Mixing.hc[hc].valveStatus, EMS_OFFSET_MMPLUSStatusMessage_valve_status);
} }
void _process_MMStatusMessage(_EMS_RxTelegram * EMS_RxTelegram) {
uint8_t hc = (EMS_RxTelegram->type - EMS_TYPE_MMStatusMessage);
if (hc!=0) {
return; // invalid type
}
EMS_Mixing.hc[hc].active = true;
_setValue(EMS_RxTelegram, &EMS_Mixing.hc[hc].flowTemp, EMS_OFFSET_MMStatusMessage_flow_temp);
_setValue(EMS_RxTelegram, &EMS_Mixing.hc[hc].pumpMod, EMS_OFFSET_MMStatusMessage_pump_mod);
//_setValue(EMS_RxTelegram, &EMS_Mixing.hc[hc].valveStatus, EMS_OFFSET_MMStatusMessage_valve_status);
_setValue(EMS_RxTelegram, &EMS_Mixing.hc[hc].flowSetTemp, EMS_OFFSET_MMStatusMessage_flow_set);
}
/** /**
* type 0x01A5 - data from the Nefit RC1010/3000 thermostat (0x18) and RC300/310s on 0x10 * type 0x01A5 - data from the Nefit RC1010/3000 thermostat (0x18) and RC300/310s on 0x10
* EMS+ messages may come in with different offsets so handle them here * EMS+ messages may come in with different offsets so handle them here
@@ -2667,7 +2683,8 @@ const _EMS_Type EMS_Types[] = {
// Mixing devices // Mixing devices
{EMS_DEVICE_UPDATE_FLAG_MIXING, EMS_TYPE_MMPLUSStatusMessage_HC1, "MMPLUSStatusMessage_HC1", _process_MMPLUSStatusMessage}, {EMS_DEVICE_UPDATE_FLAG_MIXING, EMS_TYPE_MMPLUSStatusMessage_HC1, "MMPLUSStatusMessage_HC1", _process_MMPLUSStatusMessage},
{EMS_DEVICE_UPDATE_FLAG_MIXING, EMS_TYPE_MMPLUSStatusMessage_HC2, "MMPLUSStatusMessage_HC2", _process_MMPLUSStatusMessage} {EMS_DEVICE_UPDATE_FLAG_MIXING, EMS_TYPE_MMPLUSStatusMessage_HC2, "MMPLUSStatusMessage_HC2", _process_MMPLUSStatusMessage},
{EMS_DEVICE_UPDATE_FLAG_MIXING, EMS_TYPE_MMStatusMessage, "MMStatusMessage", _process_MMStatusMessage}
}; };

View File

@@ -253,7 +253,7 @@ typedef struct {
uint8_t wWActivated; // Warm Water activated uint8_t wWActivated; // Warm Water activated
uint8_t wWSelTemp; // Warm Water selected temperature uint8_t wWSelTemp; // Warm Water selected temperature
uint8_t wWCircPump; // Warm Water circulation pump Available uint8_t wWCircPump; // Warm Water circulation pump Available
uint8_t wWDesiredTemp; // Warm Water desired temperature uint8_t wWDesinfectTemp; // Warm Water desinfection temperature
uint8_t wWComfort; // Warm water comfort or ECO mode uint8_t wWComfort; // Warm water comfort or ECO mode
// UBAMonitorFast // UBAMonitorFast
@@ -276,6 +276,7 @@ typedef struct {
// UBAMonitorSlow // UBAMonitorSlow
int16_t extTemp; // Outside temperature int16_t extTemp; // Outside temperature
uint16_t boilTemp; // Boiler temperature uint16_t boilTemp; // Boiler temperature
uint16_t exhaustTemp; // Exhaust temperature
uint8_t pumpMod; // Pump modulation uint8_t pumpMod; // Pump modulation
uint32_t burnStarts; // # burner starts uint32_t burnStarts; // # burner starts
uint32_t burnWorkMin; // Total burner operating time uint32_t burnWorkMin; // Total burner operating time
@@ -323,6 +324,7 @@ typedef struct {
uint16_t flowTemp; uint16_t flowTemp;
uint8_t pumpMod; uint8_t pumpMod;
uint8_t valveStatus; uint8_t valveStatus;
uint8_t flowSetTemp;
} _EMS_Mixing_HC; } _EMS_Mixing_HC;
// Mixer data // Mixer data

View File

@@ -196,6 +196,13 @@ const _EMS_Device_Types EMS_Devices_Types[] = {
#define EMS_OFFSET_MMPLUSStatusMessage_pump_mod 5 // pump modulation #define EMS_OFFSET_MMPLUSStatusMessage_pump_mod 5 // pump modulation
#define EMS_OFFSET_MMPLUSStatusMessage_valve_status 2 // valve in percent #define EMS_OFFSET_MMPLUSStatusMessage_valve_status 2 // valve in percent
// MM10
#define EMS_TYPE_MMStatusMessage 0xAB // mixer status
#define EMS_OFFSET_MMStatusMessage_flow_set 0 // flow setpoint
#define EMS_OFFSET_MMStatusMessage_flow_temp 1 // flow temperature
#define EMS_OFFSET_MMStatusMessage_pump_mod 3 // pump modulation in percent
#define EMS_OFFSET_MMStatusMessage_valve_status 4 // valve 0..255
/* /*
* Table of all known EMS Devices * Table of all known EMS Devices
* ProductID, DeviceType, Description, Flags * ProductID, DeviceType, Description, Flags