@@ -44,7 +44,7 @@ There are 3 parts to this project, first the design of the circuit, second the c
|
||||
|
||||
My original intention for this home project with to build my own smart thermostat for my Nefit Trendline boiler and then have it controlled via [Home Assistant](https://www.home-assistant.io/) on my mobile phone. I had a few ESP32s and ESP8266s lying around from previous IoT projects and building a specific circuit to decode the EMS messages was a nice challenge into more complex electronic circuits. I then began adding new features such as timing how long the shower was running for and triggering an alarm (actually a shot of cold water!) after a certain duration.
|
||||
|
||||
Acknowledgments and muchos kudos to the following people and their open-sourced projects:
|
||||
Acknowledgments and kudos to the following people and their open-sourced projects:
|
||||
|
||||
**susisstrolch** - Probably the first working version of the EMS bridge circuit I could find designed for the ESP8266. I borrowed Juergen's [schematic](https://github.com/susisstrolch/EMS-ESP12) and parts of his code logic.
|
||||
|
||||
@@ -64,7 +64,7 @@ I've tested the code and circuit with a few ESP8266 development boards such as t
|
||||
|
||||
1. Either build the circuit below or purchase a ready built board from bbqkees via his [GitHub](https://github.com/bbqkees/Nefit-Buderus-EMS-bus-Arduino-Domoticz) page or the [Domoticz forum](http://www.domoticz.com/forum/viewtopic.php?f=22&t=22079&start=20).
|
||||
2. Get an ESP8266 dev board and connect the 2 EMS output lines from the boiler to the circuit and the Rx/Tx out to pins D7 and D8 on the ESP. The EMS connection can either be the 12-15V AC direct from the thermostat bus line or from the 3.5" Service Jack at the front. Again bbqkees has a nice explanation [here](https://github.com/bbqkees/Nefit-Buderus-EMS-bus-Arduino-Domoticz/tree/master/Documentation).
|
||||
3. Optionally connect the three LEDs to show Rx and Tx traffic and Error codes to pins D1, D2, D3 respectively. I use 220 Ohm pull-down resistors. These pins are configurable in ``boiler.ino``. This is furtherr explained in the **code** section below.
|
||||
3. Optionally connect the three LEDs to show Rx and Tx traffic and Error codes to pins D1, D2, D3 respectively. I use 220 Ohm pull-down resistors. These pins are configurable in ``boiler.ino``. This is further explained in the **code** section below.
|
||||
4. Build and upload the firmware to the ESP8266 device. I used Platformio with Visual Studio. Do make sure you set the MQTT and WiFi credentials correctly and if you're not using MQTT leave the MQTT_IP blank. The firmware supports OTA too with the default hostname as 'boiler' (or 'boiler.' depending on your OS and how the mdns resolves hostnames).
|
||||
5. Power the ESP either via USB or direct into the 5v vin pin from an external power 5V volts supply with min 400mA.
|
||||
6. Attach the 3v3 out on the ESP8266 to the DC power line on the EMS circuit as indicated in the schematics.
|
||||
@@ -161,23 +161,23 @@ Polling is also the trigger to start transmitting any packages queued for sendin
|
||||
|
||||
When a device is broadcasting to everyone there is no specific destination needed. `[dest]` is always 0x00.
|
||||
|
||||
The Boiler (ID 0x08) will send out these broadcast telegrams regularly:
|
||||
The tables below shows which types are broadcasted regularly by the boiler (ID 0x08) and thermostat (ID 0x17). The **data length** is excluding the 4 byte header and CRC and the **Name** references those in the [ems wiki](https://emswiki.thefischer.net/doku.php?id=wiki:ems:telegramme).
|
||||
|
||||
| Type | Description (see [here](https://emswiki.thefischer.net/doku.php?id=wiki:ems:telegramme)) | Data length (excluding header) | Frequency |
|
||||
| ---- | ---------------------------------------------------------------------------------------- | ------------------------------ | ------------ |
|
||||
| 0x34 | UBAMonitorWWMessage | 19 bytes | 10 seconds |
|
||||
| 0x18 | UBAMonitorFast | 25 bytes | 10 seconds |
|
||||
| 0x19 | UBAMonitorSlow | 22 bytes | every minute |
|
||||
| 0x1C | UBAWartungsmelding | 27 bytes | every minute |
|
||||
| 0x2A | status, specific to boiler type | - | 10 seconds |
|
||||
| Source (ID) | Type ID | Name | Description | Data length | Frequency |
|
||||
| ------------- | ------- | ------------------- | -------------------------------------- | ----------- | ---------- |
|
||||
| Boiler (0x08) | 0x34 | UBAMonitorWWMessage | warm water temperature | 19 bytes | 10 seconds |
|
||||
| Boiler (0x08) | 0x18 | UBAMonitorFast | boiler temps, power, gas/pump switches | 25 bytes | 10 seconds |
|
||||
| Boiler (0x08) | 0x19 | UBAMonitorSlow | boiler temp and timings | 22 bytes | 60 seconds |
|
||||
| Boiler (0x08) | 0x1C | UBAWartungsmelding | maintenance messages | 27 bytes | 60 seconds |
|
||||
| Boiler (0x08) | 0x2A | n/a | status, specific to boiler type | 21 bytes | 10 seconds |
|
||||
| Boiler (0x08) | 0x07 | n/a | ? | 21 bytes | 30 seconds |
|
||||
|
||||
And a thermostat (ID 0x17 for a RC20) would broadcast these messages regularly:
|
||||
|
||||
| Type | Description | Comment | Frequency |
|
||||
| ---- | ---------------------- | --------------------------- | ------------ |
|
||||
| 0x06 | RC20Time | time and date on thermostat | every minute |
|
||||
| 0x91 | RC20StatusMessage | thermostat mode | every minute |
|
||||
| 0xA3 | RC20OutdoorTempMessage | external sensors | every minute |
|
||||
| Source (ID) | Type ID | Name | Description | Frequency |
|
||||
| ----------------- | ------- | ----------------- | --------------------------------------------------- | ---------- |
|
||||
| Thermostat (0x17) | 0x06 | RC20Time | returns time and date on the thermostat | 60 seconds |
|
||||
| Thermostat (0x17) | 0x91 | RC20StatusMessage | returns current and set temperatures | 60 seconds |
|
||||
| Thermostat (0x17) | 0xA3 | RCTempMessage | returns temp values from external (outdoor) sensors | 60 seconds |
|
||||
|
||||
Refer to the code in `ems.cpp` for further explanation on how to parse these message types and also reference the EMS Wiki.
|
||||
|
||||
@@ -213,14 +213,14 @@ The code is built on the Arduino framework and is dependent on these external li
|
||||
|
||||
`ems.cpp` defines callback functions that handle all the broadcast types listed above (e.g. 0x34, 0x18, 0x19 etc) plus these extra types:
|
||||
|
||||
| Device (ID) | Type | Description | What |
|
||||
| ----------------- | ---- | ----------------------------- | ---------------------------------------- |
|
||||
| Boiler (0x08) | 0x33 | UBAParameterWW | reads selected & desired warm water temp |
|
||||
| Boiler (0x08) | 0x14 | UBATotalUptimeMessage | |
|
||||
| Boiler (0x08) | 0x15 | UBAMaintenanceSettingsMessage | |
|
||||
| Boiler (0x08) | 0x16 | UBAParametersMessage | |
|
||||
| Thermostat (0x17) | 0xA8 | RC20Temperature | sets temperature and operating modes |
|
||||
| Thermostat (0x17) | 0x02 | Version | reads Version major/minor |
|
||||
| Source (ID) | Type ID | Name | Description |
|
||||
| ----------------- | ------- | ----------------------------- | ---------------------------------------- |
|
||||
| Boiler (0x08) | 0x33 | UBAParameterWW | reads selected & desired warm water temp |
|
||||
| Boiler (0x08) | 0x14 | UBATotalUptimeMessage | |
|
||||
| Boiler (0x08) | 0x15 | UBAMaintenanceSettingsMessage | |
|
||||
| Boiler (0x08) | 0x16 | UBAParametersMessage | |
|
||||
| Thermostat (0x17) | 0xA8 | RC20Temperature | sets operating modes |
|
||||
| Thermostat (0x17) | 0x02 | Version | reads Version major/minor |
|
||||
|
||||
In `boiler.ino` you can make calls to automatically send these read commands. See the function *regularUpdates()*
|
||||
|
||||
@@ -422,10 +422,10 @@ pre-baked firmwares for some ESP8266 devices based on ESPurna are available in t
|
||||
2. Install the ESPTool by running `pip install esptool` from a command prompt
|
||||
3. Connect the ESP via USB, figure out the COM port
|
||||
4. run `esptool.py -p <com> write_flash 0x00000 <firmware>` where firmware is the `.bin` file and \<com\> is the COM port, e.g. `COM3`
|
||||
5. Connect using WiFi from a phone or PC to the "**ESPURNA_XXXXXX**" network. Pasword is '**fibonacci**'
|
||||
5. Connect using WiFi from a phone or PC to the "**ESPURNA_XXXXXX**" network. Password is '**fibonacci**'
|
||||
6. Once connected browse to "http://192.168.4.1" and setup your wifi, mqtt etc
|
||||
|
||||
Again, if you run into problems read [this](https://github.com/xoseperez/espurna/wiki/Configuration) from ESPurna's configuation help page.
|
||||
Again, if you run into problems read [this](https://github.com/xoseperez/espurna/wiki/Configuration) from ESPurna's configuration help page.
|
||||
|
||||
### Using the Arduino IDE
|
||||
|
||||
|
||||