mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-08 00:39:50 +03:00
warm water modes
This commit is contained in:
31
src/ems.cpp
31
src/ems.cpp
@@ -892,7 +892,7 @@ void _process_UBAParameterWW(uint8_t type, uint8_t * data, uint8_t length) {
|
||||
EMS_Boiler.wWSelTemp = data[2];
|
||||
EMS_Boiler.wWCircPump = (data[6] == 0xFF); // 0xFF means on
|
||||
EMS_Boiler.wWDesiredTemp = data[8];
|
||||
EMS_Boiler.wWComfort = (data[EMS_OFFSET_UBAParameterWW_wwComfort] == 0x00);
|
||||
EMS_Boiler.wWComfort = data[EMS_OFFSET_UBAParameterWW_wwComfort];
|
||||
|
||||
EMS_Sys_Status.emsRefreshed = true; // when we receieve this, lets force an MQTT publish
|
||||
}
|
||||
@@ -1098,7 +1098,6 @@ void _process_Version(uint8_t type, uint8_t * data, uint8_t length) {
|
||||
return;
|
||||
}
|
||||
|
||||
bool do_save = false;
|
||||
uint8_t product_id = data[0];
|
||||
char version[10] = {0};
|
||||
snprintf(version, sizeof(version), "%02d.%02d", data[1], data[2]);
|
||||
@@ -1135,7 +1134,7 @@ void _process_Version(uint8_t type, uint8_t * data, uint8_t length) {
|
||||
EMS_Boiler.product_id = Boiler_Types[i].product_id;
|
||||
strlcpy(EMS_Boiler.version, version, sizeof(EMS_Boiler.version));
|
||||
|
||||
do_save = true;
|
||||
myESP.fs_saveConfig(); // save config to SPIFFS
|
||||
|
||||
ems_getBoilerValues(); // get Boiler values that we would usually have to wait for
|
||||
}
|
||||
@@ -1178,7 +1177,7 @@ void _process_Version(uint8_t type, uint8_t * data, uint8_t length) {
|
||||
EMS_Thermostat.product_id = product_id;
|
||||
strlcpy(EMS_Thermostat.version, version, sizeof(EMS_Thermostat.version));
|
||||
|
||||
do_save = true;
|
||||
myESP.fs_saveConfig(); // save config to SPIFFS
|
||||
|
||||
// get Thermostat values (if supported)
|
||||
ems_getThermostatValues();
|
||||
@@ -1187,10 +1186,6 @@ void _process_Version(uint8_t type, uint8_t * data, uint8_t length) {
|
||||
myDebug("Unrecognized device found. TypeID 0x%02X, Product ID %d, Version %s", type, product_id, version);
|
||||
}
|
||||
|
||||
// if the boiler or thermostat values have changed, save them to SPIFFS
|
||||
if (do_save) {
|
||||
myESP.fs_saveConfig();
|
||||
}
|
||||
}
|
||||
|
||||
/*
|
||||
@@ -1737,22 +1732,32 @@ void ems_setWarmWaterTemp(uint8_t temperature) {
|
||||
|
||||
/**
|
||||
* Set the warm water mode to comfort to Eco/Comfort
|
||||
* 1 = Hot, 2 = Eco, 3 = Intelligent
|
||||
*/
|
||||
void ems_setWarmWaterModeComfort(bool comfort) {
|
||||
myDebug("Setting boiler warm water to comfort mode %s\n", comfort ? "Comfort" : "Eco");
|
||||
|
||||
void ems_setWarmWaterModeComfort(uint8_t comfort) {
|
||||
_EMS_TxTelegram EMS_TxTelegram = EMS_TX_TELEGRAM_NEW; // create new Tx
|
||||
EMS_TxTelegram.timestamp = millis(); // set timestamp
|
||||
EMS_Sys_Status.txRetryCount = 0; // reset retry counter
|
||||
|
||||
if (comfort == 1) {
|
||||
myDebug("Setting boiler warm water comfort mode to Comfort");
|
||||
EMS_TxTelegram.dataValue = EMS_VALUE_UBAParameterWW_wwComfort_Hot;
|
||||
} else if (comfort == 2) {
|
||||
myDebug("Setting boiler warm water comfort mode to Eco");
|
||||
EMS_TxTelegram.dataValue = EMS_VALUE_UBAParameterWW_wwComfort_Eco;
|
||||
} else if (comfort == 3) {
|
||||
myDebug("Setting boiler warm water comfort mode to Intelligent");
|
||||
EMS_TxTelegram.dataValue = EMS_VALUE_UBAParameterWW_wwComfort_Intelligent;
|
||||
} else {
|
||||
return; // invalid comfort value
|
||||
}
|
||||
|
||||
EMS_TxTelegram.action = EMS_TX_TELEGRAM_WRITE;
|
||||
EMS_TxTelegram.dest = EMS_Boiler.type_id;
|
||||
EMS_TxTelegram.type = EMS_TYPE_UBAParameterWW;
|
||||
EMS_TxTelegram.offset = EMS_OFFSET_UBAParameterWW_wwComfort;
|
||||
EMS_TxTelegram.length = EMS_MIN_TELEGRAM_LENGTH;
|
||||
EMS_TxTelegram.type_validate = EMS_ID_NONE; // don't validate
|
||||
EMS_TxTelegram.dataValue =
|
||||
(comfort ? EMS_VALUE_UBAParameterWW_wwComfort_Comfort : EMS_VALUE_UBAParameterWW_wwComfort_Eco); // 0x00 is on, 0xD8 is off
|
||||
|
||||
EMS_TxQueue.push(EMS_TxTelegram);
|
||||
}
|
||||
|
||||
Reference in New Issue