code cleanup, thermostat mqtt changes, dallas sensor to 2 precision doubles
This commit is contained in:
55
src/ems.cpp
55
src/ems.cpp
@@ -210,7 +210,7 @@ _EMS_Thermostat EMS_Thermostat; // for thermostat
|
||||
_EMS_SolarModule EMS_SolarModule; // for solar modules
|
||||
_EMS_HeatPump EMS_HeatPump; // for heatpumps
|
||||
_EMS_Mixing EMS_Mixing; // for mixing devices
|
||||
_EMS_Other EMS_Other; // for other known EMS devices
|
||||
_EMS_Other EMS_Other; // for other known EMS devices
|
||||
|
||||
// CRC lookup table with poly 12 for faster checking
|
||||
const uint8_t ems_crc_table[] = {0x00, 0x02, 0x04, 0x06, 0x08, 0x0A, 0x0C, 0x0E, 0x10, 0x12, 0x14, 0x16, 0x18, 0x1A, 0x1C, 0x1E, 0x20, 0x22, 0x24, 0x26,
|
||||
@@ -655,7 +655,7 @@ void _ems_sendTelegram() {
|
||||
EMS_TxTelegram.data[1] = EMS_TxTelegram.dest;
|
||||
} else {
|
||||
// for a READ or VALIDATE
|
||||
EMS_TxTelegram.data[1] = (EMS_TxTelegram.dest | 0x80); // read has 8th bit set, always
|
||||
EMS_TxTelegram.data[1] = (EMS_TxTelegram.dest | 0x80); // read has 8th bit set, always
|
||||
}
|
||||
|
||||
// complete the rest of the header depending on EMS or EMS+
|
||||
@@ -1489,13 +1489,12 @@ void _process_EasyStatusMessage(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
|
||||
void _process_MMPLUSStatusMessage(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
uint8_t hc = (EMS_RxTelegram->type - EMS_TYPE_MMPLUSStatusMessage_HC1); // 0 to 3
|
||||
if (hc > 4) {
|
||||
if (hc > EMS_THERMOSTAT_MAXHC) {
|
||||
return; // invalid type
|
||||
}
|
||||
EMS_Mixing.hc[hc].active = true;
|
||||
|
||||
if (EMS_RxTelegram->data_length == 1) {
|
||||
|
||||
if (EMS_RxTelegram->data_length == 1) {
|
||||
} else if (EMS_RxTelegram->data_length > 8) {
|
||||
EMS_Mixing.hc[hc].flowTemp = _toShort(EMS_OFFSET_MMPLUSStatusMessage_flow_temp);
|
||||
}
|
||||
@@ -1508,7 +1507,7 @@ void _process_MMPLUSStatusMessage(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
void _process_RCPLUSStatusMessage(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
// figure out which heating circuit
|
||||
uint8_t hc = (EMS_RxTelegram->type - EMS_TYPE_RCPLUSStatusMessage_HC1); // 0 to 3
|
||||
if (hc > 4) {
|
||||
if (hc > EMS_THERMOSTAT_MAXHC) {
|
||||
return; // invalid type
|
||||
}
|
||||
EMS_Thermostat.hc[hc].active = true;
|
||||
@@ -1567,7 +1566,7 @@ void _process_JunkersStatusMessage(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
EMS_Thermostat.hc[hc].curr_roomTemp = _toShort(EMS_OFFSET_JunkersStatusMessage_curr); // value is * 10
|
||||
EMS_Thermostat.hc[hc].setpoint_roomTemp = _toShort(EMS_OFFSET_JunkersStatusMessage_setpoint); // value is * 10
|
||||
EMS_Thermostat.hc[hc].mode = _toByte(EMS_OFFSET_JunkersStatusMessage_mode);
|
||||
EMS_Sys_Status.emsRefreshed = true; // triggers a send the values back via MQTT
|
||||
EMS_Sys_Status.emsRefreshed = true; // triggers a send the values back via MQTT
|
||||
}
|
||||
}
|
||||
|
||||
@@ -2203,47 +2202,12 @@ void _process_Version(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
}
|
||||
}
|
||||
|
||||
/*
|
||||
* See if we have a Junkers Heatronic 3 compatible device
|
||||
* Do a read command for the version with the src having the MSB set
|
||||
*/
|
||||
void _ems_detectJunkers() {
|
||||
#ifdef JUNKERS_DETECT
|
||||
char s[30] = {0};
|
||||
snprintf(s, sizeof(s), "%02X %02X %02X 00 %02X", (EMS_ID_ME | 0x80), (EMS_ID_BOILER | 0x080), EMS_TYPE_Version, EMS_MAX_TELEGRAM_LENGTH);
|
||||
ems_sendRawTelegram(s);
|
||||
#endif
|
||||
}
|
||||
|
||||
/*
|
||||
* Figure out the boiler and thermostat types
|
||||
*/
|
||||
void ems_discoverModels() {
|
||||
myDebug_P(PSTR("Starting auto discover of EMS devices..."));
|
||||
ems_doReadCommand(EMS_TYPE_UBADevices, EMS_ID_BOILER);
|
||||
|
||||
// ems_startupTelegrams();
|
||||
|
||||
// TODO remove this part eventually, ems_discoverModels()
|
||||
/*
|
||||
|
||||
// boiler...
|
||||
// ems_doReadCommand(EMS_TYPE_Version, EMS_ID_BOILER);
|
||||
// _ems_detectJunkers(); // special hack for Junkers detection
|
||||
|
||||
ems_doReadCommand(EMS_TYPE_Version, EMS_ID_SM); // check if there is Solar Module available
|
||||
ems_doReadCommand(EMS_TYPE_Version, EMS_ID_HP); // check if there is HeatPump Module available
|
||||
|
||||
// thermostat...
|
||||
// if it hasn't been set, auto discover it
|
||||
if (EMS_Thermostat.device_id == EMS_ID_NONE) {
|
||||
ems_scanDevices(); // auto-discover it
|
||||
} else {
|
||||
// set the model as hardcoded (see my_devices.h) and fetch the version and product id
|
||||
ems_doReadCommand(EMS_TYPE_Version, EMS_Thermostat.device_id);
|
||||
}
|
||||
|
||||
*/
|
||||
}
|
||||
|
||||
/**
|
||||
@@ -2592,9 +2556,6 @@ void ems_scanDevices() {
|
||||
for (uint8_t device_id : Device_Ids) {
|
||||
ems_doReadCommand(EMS_TYPE_Version, device_id);
|
||||
}
|
||||
|
||||
// add a check for Junkers onto the queue
|
||||
_ems_detectJunkers();
|
||||
}
|
||||
|
||||
/**
|
||||
@@ -2845,7 +2806,7 @@ void ems_setThermostatTemp(float temperature, uint8_t hc_num, uint8_t temptype)
|
||||
return;
|
||||
}
|
||||
|
||||
if (hc_num < 1 || hc_num > 4) {
|
||||
if (hc_num < 1 || hc_num > EMS_THERMOSTAT_MAXHC) {
|
||||
myDebug_P(PSTR("Invalid HC number"));
|
||||
return;
|
||||
}
|
||||
@@ -2955,7 +2916,7 @@ void ems_setThermostatMode(uint8_t mode, uint8_t hc_num) {
|
||||
return;
|
||||
}
|
||||
|
||||
if (hc_num < 1 || hc_num > 4) {
|
||||
if (hc_num < 1 || hc_num > EMS_THERMOSTAT_MAXHC) {
|
||||
myDebug_P(PSTR("Invalid HC number"));
|
||||