Added print messages and got temperature setpoitn working

This commit is contained in:
Glenn Arens
2019-03-07 20:39:50 +01:00
parent 7f3d27d03d
commit a94b88ad9e
3 changed files with 67 additions and 43 deletions

View File

@@ -59,6 +59,9 @@ void _process_RC35StatusMessage(uint8_t type, uint8_t * data, uint8_t length);
void _process_EasyStatusMessage(uint8_t type, uint8_t * data, uint8_t length);
//EMS Plus
void _process_EmsPlusStatusMessage(uint8_t type, uint8_t * data, uint8_t length);
//debug messages
void _printMessage(uint8_t * telegram, uint8_t length);
/*
* Recognized EMS types and the functions they call to process the telegrams
* Format: MODEL ID, TYPE ID, Description, function
@@ -116,7 +119,7 @@ const _EMS_Type EMS_Types[] = {
{EMS_MODEL_EASY, EMS_TYPE_EasyStatusMessage, "EasyStatusMessage", _process_EasyStatusMessage},
{EMS_MODEL_BOSCHEASY, EMS_TYPE_EasyStatusMessage, "EasyStatusMessage", _process_EasyStatusMessage},
//Ems plus
{EMSP_MODEL_RC10, EMS_TYPE_EmsPlusStatusMessage, "EasyStatusMessage", _process_EmsPlusStatusMessage}
{EMSP_MODEL_RC10, EMS_TYPE_EmsPlusStatusMessage, "EMSPStatusMessage", _process_EmsPlusStatusMessage}
};
@@ -652,7 +655,48 @@ void _ems_processTelegram(uint8_t * telegram, uint8_t length) {
uint8_t type = telegram[2];
uint8_t offset = telegram[3];
uint8_t * data = telegram + 4; // data block starts at position 5
_printMessage(telegram, length);
// see if we recognize the type first by scanning our known EMS types list
// trying to match the type ID
bool commonType = false;
bool typeFound = false;
bool forUs = false;
int i = 0;
while (i < _EMS_Types_max) {
if (EMS_Types[i].type == type) {
typeFound = true;
commonType = (EMS_Types[i].model_id == EMS_MODEL_ALL); // is it common type for everyone?
forUs = (src == EMS_Boiler.type_id) || (src == EMS_Thermostat.type_id); // is it for us? So the src must match
break;
}
i++;
}
// if it's a common type (across ems devices) or something specifically for us process it.
// dest will be EMS_ID_NONE and offset 0x00 for a broadcast message
if (typeFound && (commonType || forUs)) {
if ((EMS_Types[i].processType_cb) != (void *)NULL) {
// print non-verbose message
if ((EMS_Sys_Status.emsLogging == EMS_SYS_LOGGING_BASIC) || (EMS_Sys_Status.emsLogging == EMS_SYS_LOGGING_VERBOSE)) {
myDebug("<--- %s(0x%02X) received", EMS_Types[i].typeString, type);
}
// call callback function to process it
// as we only handle complete telegrams (not partial) check that the offset is 0
if (offset == EMS_ID_NONE) {
(void)EMS_Types[i].processType_cb(type, data, length - 5);
} else if (type == 255)
(void)EMS_Types[i].processType_cb(type, telegram, length);
}
}
}
void _printMessage(uint8_t * telegram, uint8_t length) {
uint8_t src = telegram[0] & 0x7F;
uint8_t dest = telegram[1] & 0x7F; // remove 8th bit to handle both reads and writes
uint8_t type = telegram[2];
uint8_t offset = telegram[3];
uint8_t * data = telegram + 4; // data block starts at position 5
// print detailed telegram data
if (EMS_Sys_Status.emsLogging >= EMS_SYS_LOGGING_THERMOSTAT) {
char output_str[300] = {0}; // roughly EMS_MAX_TELEGRAM_LENGTH*3 + 20
@@ -704,39 +748,6 @@ void _ems_processTelegram(uint8_t * telegram, uint8_t length) {
_debugPrintTelegram(output_str, telegram, length, color_s);
}
}
// see if we recognize the type first by scanning our known EMS types list
// trying to match the type ID
bool commonType = false;
bool typeFound = false;
bool forUs = false;
int i = 0;
while (i < _EMS_Types_max) {
if (EMS_Types[i].type == type) {
typeFound = true;
commonType = (EMS_Types[i].model_id == EMS_MODEL_ALL); // is it common type for everyone?
forUs = (src == EMS_Boiler.type_id) || (src == EMS_Thermostat.type_id); // is it for us? So the src must match
break;
}
i++;
}
// if it's a common type (across ems devices) or something specifically for us process it.
// dest will be EMS_ID_NONE and offset 0x00 for a broadcast message
if (typeFound && (commonType || forUs)) {
if ((EMS_Types[i].processType_cb) != (void *)NULL) {
// print non-verbose message
if ((EMS_Sys_Status.emsLogging == EMS_SYS_LOGGING_BASIC) || (EMS_Sys_Status.emsLogging == EMS_SYS_LOGGING_VERBOSE)) {
myDebug("<--- %s(0x%02X) received", EMS_Types[i].typeString, type);
}
// call callback function to process it
// as we only handle complete telegrams (not partial) check that the offset is 0
if (offset == EMS_ID_NONE) {
(void)EMS_Types[i].processType_cb(type, data, length - 5);
}
}
}
}
/**
@@ -1040,10 +1051,24 @@ void _process_EasyStatusMessage(uint8_t type, uint8_t * data, uint8_t length) {
EMS_Sys_Status.emsRefreshed = true; // triggers a send the values back via MQTT
}
void _process_EmsPlusStatusMessage(uint8_t type, uint8_t * data, uint8_t length) {
myDebug("The type is ", type);
myDebug("The data is ", data);
myDebug("The length is ", length);
if (data[3] == 3 || data[3] == 6 || data[3] == 10) {
EMS_Thermostat.setpoint_roomTemp = ((float)data[6]) / (float)2;
if (true) {
char str[300];
char buffer[16];
for (size_t i = 0; i < length; i++) {
strlcat(str, _hextoa(data[i], buffer), sizeof(str));
strlcat(str, " ", sizeof(str)); // add space
}
myDebug(str);
}
}
//EMS_Sys_Status.emsLogging = EMS_SYS_LOGGING_NONE;
}
/*
strlcat(output_str, ", type 0x", sizeof(output_str));
strlcat(output_str, _hextoa(type, buffer), sizeof(output_str));
*/
/**
* type 0xB0 - for reading the mode from the RC10 thermostat (0x17)
* received only after requested

View File

@@ -84,7 +84,7 @@
#define EMS_TYPE_EasyStatusMessage_setpoint 10 // setpoint temp
#define EMS_TYPE_EasyStatusMessage_curr 8 // current temp
// Ems plus
#define EMS_TYPE_EmsPlusStatusMessage 0x00 // reading values on an Easy Thermostat
#define EMS_TYPE_EmsPlusStatusMessage 0xFF // reading values on an Easy Thermostat
#define EMS_TYPE_EmsPlusStatusMessage_setpoint 0 // setpoint temp
#define EMS_TYPE_EmsPlusStatusMessage_curr 0 // current temp
// Known EMS types
@@ -125,7 +125,7 @@ const _Boiler_Type Boiler_Types[] = {
{EMS_MODEL_UBA, 125, 0x09, "BC25 Base Controller"},
{EMS_MODEL_UBA, 68, 0x09, "RFM20 Receiver"},
{EMS_MODEL_UBA, 95, 0x08, "Bosch Condens 2500"},
{EMS_MODEL_UBA, 205, 0x02, "Nefit Moduline Easy Connect"},
{EMS_MODEL_UBA, 205, 0x08, "Nefit Moduline Easy Connect"},
{EMS_MODEL_UBA, 251, 0x21, "MM10 Mixer Module"}, // warning, fake product id!
{EMS_MODEL_UBA, 250, 0x11, "WM10 Switch Module"}, // warning, fake product id!
};
@@ -145,6 +145,5 @@ const _Thermostat_Type Thermostat_Types[] = {
{EMS_MODEL_BOSCHEASY, 206, 0x02, "Bosch Easy", EMS_THERMOSTAT_READ_YES, EMS_THERMOSTAT_WRITE_NO},
{EMS_MODEL_RC310, 158, 0x10, "RC310", EMS_THERMOSTAT_READ_NO, EMS_THERMOSTAT_WRITE_NO},
{EMS_MODEL_CW100, 255, 0x18, "Bosch CW100", EMS_THERMOSTAT_READ_NO, EMS_THERMOSTAT_WRITE_NO},
{EMSP_MODEL_RC10, 165, 0x02, "RC10/Nefit Moduline 1010)", EMS_THERMOSTAT_READ_YES, EMS_THERMOSTAT_WRITE_YES},
{EMSP_MODEL_RC10, 165, 0x18, "RC10/Nefit Moduline 1010)", EMS_THERMOSTAT_READ_YES, EMS_THERMOSTAT_WRITE_NO},
};

View File

@@ -45,7 +45,7 @@
#define TOPIC_SHOWER_COLDSHOT "shower_coldshot" // used to trigger a coldshot from an MQTT command
// default values for shower logic on/off
#define BOILER_SHOWER_TIMER 1 // enable (1) to monitor shower time
#define BOILER_SHOWER_TIMER 0 // enable (1) to monitor shower time
#define BOILER_SHOWER_ALERT 0 // enable (1) to send alert of cold water when shower time limit has exceeded
#define SHOWER_MAX_DURATION 420000 // in ms. 7 minutes, before trigger a shot of cold water