add boiler wWType, fix wwontime readback
This commit is contained in:
@@ -360,6 +360,17 @@ void Boiler::show_values(uuid::console::Shell & shell) {
|
||||
if (Helpers::hasValue(wWCircPumpType_, EMS_VALUE_BOOL)) {
|
||||
print_value(shell, 2, F("Warm Water charging type"), wWCircPumpType_ ? F("3-way valve") : F("charge pump"));
|
||||
}
|
||||
if (wWType_ == 0) {
|
||||
print_value(shell, 2, F("Warm Water type"), F("off"));
|
||||
} else if (wWType_ == 1) {
|
||||
print_value(shell, 2, F("Warm Water type"), F("flow"));
|
||||
} else if (wWType_ == 2) {
|
||||
print_value(shell, 2, F("Warm Water type"), F("buffered flow"));
|
||||
} else if (wWType_ == 3) {
|
||||
print_value(shell, 2, F("Warm Water type"), F("buffer"));
|
||||
} else if (wWType_ == 4) {
|
||||
print_value(shell, 2, F("Warm Water type"), F("layered buffer"));
|
||||
}
|
||||
print_value(shell, 2, F("Warm Water circulation pump available"), wWCircPump_, nullptr, EMS_VALUE_BOOL);
|
||||
|
||||
if (Helpers::hasValue(wWCircPumpMode_)) {
|
||||
@@ -400,6 +411,7 @@ void Boiler::show_values(uuid::console::Shell & shell) {
|
||||
if (Helpers::hasValue(wWWorkM_)) {
|
||||
shell.printfln(F(" Warm Water active time: %d days %d hours %d minutes"), wWWorkM_ / 1440, (wWWorkM_ % 1440) / 60, wWWorkM_ % 60);
|
||||
}
|
||||
print_value(shell, 2, F("Warm Water one time charging"), wWOneTime_, nullptr, EMS_VALUE_BOOL);
|
||||
print_value(shell, 2, F("Warm Water charging"), wWHeat_, nullptr, EMS_VALUE_BOOL);
|
||||
print_value(shell, 2, F("Warm Water disinfecting"), wWDisinfecting_, nullptr, EMS_VALUE_BOOL);
|
||||
print_value(shell, 2, F("Selected flow temperature"), selFlowTemp_, F_(degrees));
|
||||
@@ -467,14 +479,14 @@ void Boiler::show_values(uuid::console::Shell & shell) {
|
||||
void Boiler::check_active() {
|
||||
// hot tap water, using flow to check instead of the burner power
|
||||
// send these values back to the main EMSESP, so other classes (e.g. Shower) can use it
|
||||
if (Helpers::hasValue(wWCurFlow_) && Helpers::hasValue(burnGas_)) {
|
||||
if (Helpers::hasValue(wWCurFlow_) && Helpers::hasValue(burnGas_) && (wWType_ > 0) && (wWType_ < 3)) {
|
||||
tap_water_active_ = ((wWCurFlow_ != 0) && (burnGas_ != EMS_VALUE_BOOL_OFF));
|
||||
EMSESP::tap_water_active(tap_water_active_);
|
||||
}
|
||||
|
||||
// heating
|
||||
// using a quick hack for checking the heating by looking at the Selected Flow Temp, but doesn't work for all boilers apparently
|
||||
if (Helpers::hasValue(selFlowTemp_) && Helpers::hasValue(burnGas_)) {
|
||||
if (Helpers::hasValue(tap_water_active_, EMS_VALUE_BOOL) && Helpers::hasValue(selFlowTemp_) && Helpers::hasValue(burnGas_)) {
|
||||
heating_active_ = (!tap_water_active_ && ((selFlowTemp_ >= EMS_BOILER_SELFLOWTEMP_HEATING) && (burnGas_ != EMS_VALUE_BOOL_OFF)));
|
||||
}
|
||||
|
||||
@@ -571,6 +583,7 @@ void Boiler::process_UBAMonitorWW(std::shared_ptr<const Telegram> telegram) {
|
||||
changed_ |= telegram->read_value(wWCurTmp_, 1);
|
||||
changed_ |= telegram->read_value(wWCurTmp2_, 3);
|
||||
changed_ |= telegram->read_value(wWCurFlow_, 9);
|
||||
changed_ |= telegram->read_value(wWType_, 8);
|
||||
|
||||
changed_ |= telegram->read_value(wWWorkM_, 10, 3); // force to 3 bytes
|
||||
changed_ |= telegram->read_value(wWStarts_, 13, 3); // force to 3 bytes
|
||||
@@ -663,8 +676,9 @@ void Boiler::process_UBAParameterWWPlus(std::shared_ptr<const Telegram> telegram
|
||||
changed_ |= telegram->read_value(wWActivated_, 5); // 0x01 means on
|
||||
changed_ |= telegram->read_value(wWCircPump_, 10); // 0x01 means yes
|
||||
changed_ |= telegram->read_value(wWCircPumpMode_, 11); // 1=1x3min... 6=6x3min, 7=continuous
|
||||
// changed_ |= telegram->read_value(wWDisinfectTemp_, 12); // also in E9
|
||||
// changed_ |= telegram->read_value(wWSelTemp_, 6);
|
||||
// changed_ |= telegram->read_value(wWDisinfectTemp_, 12); // settings, status in E9
|
||||
// changed_ |= telegram->read_value(wWSelTemp_, 6); // settings, status in E9
|
||||
|
||||
}
|
||||
|
||||
// 0xE9 - DHW Status
|
||||
@@ -684,7 +698,7 @@ void Boiler::process_UBADHWStatus(std::shared_ptr<const Telegram> telegram) {
|
||||
changed_ |= telegram->read_bitvalue(wWTemperatureOK_, 13, 5);
|
||||
changed_ |= telegram->read_bitvalue(wWCircPump_, 13, 2);
|
||||
|
||||
changed_ |= telegram->read_value(wWActivated_, 20);
|
||||
// changed_ |= telegram->read_value(wWActivated_, 20); // Activated is in 0xEA, this is something other 0/100%
|
||||
changed_ |= telegram->read_value(wWSelTemp_, 10);
|
||||
changed_ |= telegram->read_value(wWDisinfectTemp_, 9);
|
||||
}
|
||||
@@ -883,8 +897,10 @@ void Boiler::set_pump_delay(const char * value, const int8_t id) {
|
||||
return;
|
||||
}
|
||||
|
||||
LOG_INFO(F("Setting boiler pump delay to %d min"), v);
|
||||
write_command(EMS_TYPE_UBAParameters, 8, v, EMS_TYPE_UBAParameters);
|
||||
if (get_toggle_fetch(EMS_TYPE_UBAParameters)) {
|
||||
LOG_INFO(F("Setting boiler pump delay to %d min"), v);
|
||||
write_command(EMS_TYPE_UBAParameters, 8, v, EMS_TYPE_UBAParameters);
|
||||
}
|
||||
}
|
||||
|
||||
// note some boilers do not have this setting, than it's done by thermostat
|
||||
@@ -893,6 +909,9 @@ void Boiler::set_warmwater_mode(const char * value, const int8_t id) {
|
||||
if (value == nullptr) {
|
||||
return;
|
||||
}
|
||||
if (!get_toggle_fetch(EMS_TYPE_UBAParameterWW)) {
|
||||
return;
|
||||
}
|
||||
uint8_t set;
|
||||
if (strcmp(value, "hot") == 0) {
|
||||
LOG_INFO(F("Setting boiler warm water to Hot"));
|
||||
@@ -974,7 +993,11 @@ void Boiler::set_warmwater_onetime(const char * value, const int8_t id) {
|
||||
}
|
||||
|
||||
LOG_INFO(F("Setting boiler warm water OneTime loading %s"), v ? "on" : "off");
|
||||
write_command(EMS_TYPE_UBAFlags, 0, (v ? 0x22 : 0x02), 0x18);
|
||||
if (get_toggle_fetch(EMS_TYPE_UBAParameterWWPlus)) {
|
||||
write_command(EMS_TYPE_UBAFlags, 0, (v ? 0x22 : 0x02), 0xE9); // not sure if this is in flags
|
||||
} else {
|
||||
write_command(EMS_TYPE_UBAFlags, 0, (v ? 0x22 : 0x02), 0x34);
|
||||
}
|
||||
}
|
||||
|
||||
// Activate / De-activate circulation of warm water 0x35
|
||||
@@ -986,7 +1009,11 @@ void Boiler::set_warmwater_circulation(const char * value, const int8_t id) {
|
||||
}
|
||||
|
||||
LOG_INFO(F("Setting boiler warm water circulation %s"), v ? "on" : "off");
|
||||
write_command(EMS_TYPE_UBAFlags, 1, (v ? 0x22 : 0x02), 0x18);
|
||||
if (get_toggle_fetch(EMS_TYPE_UBAParameterWWPlus)) {
|
||||
write_command(EMS_TYPE_UBAFlags, 1, (v ? 0x22 : 0x02), 0xE9); // not sure if this is in flags
|
||||
} else {
|
||||
write_command(EMS_TYPE_UBAFlags, 1, (v ? 0x22 : 0x02), 0x34);
|
||||
}
|
||||
}
|
||||
|
||||
// add console commands
|
||||
|
||||
@@ -119,6 +119,7 @@ class Boiler : public EMSdevice {
|
||||
uint8_t wWRecharging_ = EMS_VALUE_BOOL_NOTSET; // Warm Water recharge on/off
|
||||
uint8_t wWTemperatureOK_ = EMS_VALUE_BOOL_NOTSET; // Warm Water temperature ok on/off
|
||||
uint8_t wWCurFlow_ = EMS_VALUE_UINT_NOTSET; // Warm Water current flow temp in l/min
|
||||
uint8_t wWType_ = EMS_VALUE_UINT_NOTSET; // 0-off, 1-flow, 2-flowbuffer, 3-buffer, 4-layered buffer
|
||||
|
||||
// UBATotalUptime
|
||||
uint32_t UBAuptime_ = EMS_VALUE_ULONG_NOTSET; // Total UBA working hours
|
||||
|
||||
Reference in New Issue