@@ -178,6 +178,7 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &curBurnPow_, DeviceValueType::UINT, nullptr, FL_(curBurnPow), DeviceValueUOM::PERCENT);
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &burnStarts_, DeviceValueType::ULONG, nullptr, FL_(burnStarts), DeviceValueUOM::NONE);
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &burnWorkMin_, DeviceValueType::TIME, nullptr, FL_(burnWorkMin), DeviceValueUOM::MINUTES);
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &burn2WorkMin_, DeviceValueType::TIME, nullptr, FL_(burn2WorkMin), DeviceValueUOM::MINUTES);
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &heatWorkMin_, DeviceValueType::TIME, nullptr, FL_(heatWorkMin), DeviceValueUOM::MINUTES);
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &UBAuptime_, DeviceValueType::TIME, nullptr, FL_(UBAuptime), DeviceValueUOM::MINUTES);
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &lastCode_, DeviceValueType::STRING, nullptr, FL_(lastCode), DeviceValueUOM::NONE);
@@ -253,7 +254,7 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
DeviceValueUOM::NONE,
MAKE_CF_CB(set_energyCostRatio),
0,
19.9);
20);
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA,
&fossileFactor_,
DeviceValueType::UINT,
@@ -414,7 +415,7 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
FL_(enum_comfort1),
FL_(wwComfort1),
DeviceValueUOM::NONE,
MAKE_CF_CB(set_ww_mode1));
MAKE_CF_CB(set_ww_mode));
register_device_value(DeviceValueTAG::TAG_BOILER_DATA_WW,
&wwFlowTempOffset_,
DeviceValueType::UINT,
@@ -1549,55 +1550,23 @@ bool Boiler::set_pump_delay(const char * value, const int8_t id) {
// note some boilers do not have this setting, than it's done by thermostat
// on a RC35 it's by EMSESP::send_write_request(0x37, 0x10, 2, &set, 1, 0); (set is 1,2,3) 1=hot, 2=eco, 3=intelligent
// on a RC310 it's 1=high, 2=eco
bool Boiler::set_ww_mode(const char * value, const int8_t id) {
uint8_t set;
if (!Helpers::value2enum(value, set, FL_(enum_comfort))) {
return false;
}
uint8_t comfort[] = {0x00, 0xD8, 0xEC};
if (!is_fetch(EMS_TYPE_UBAParameterWW)) {
return false;
}
if (set == 0) {
// LOG_INFO(F("Setting boiler dhw to Hot"));
} else if (set == 1) {
// LOG_INFO(F("Setting boiler dhw to Eco"));
set = 0xD8;
} else if (set == 2) {
// LOG_INFO(F("Setting boiler dhw to Intelligent"));
set = 0xEC;
if (is_fetch(EMS_TYPE_UBAParameterWWPlus)) {
if (Helpers::value2enum(value, set, FL_(enum_comfort1))) {
write_command(EMS_TYPE_UBAParameterWWPlus, 13, comfort[set], EMS_TYPE_UBAParameterWWPlus);
return true;
}
} else {
return false; // do nothing
if (Helpers::value2enum(value, set, FL_(enum_comfort))) {
write_command(EMS_TYPE_UBAParameterWW, 9, comfort[set], EMS_TYPE_UBAParameterWW);
return true;
}
}
write_command(EMS_TYPE_UBAParameterWW, 9, set, EMS_TYPE_UBAParameterWW);
return true;
}
// wwcomfort1 for RC310
// on a RC310 it's 1=high, 2=eco
bool Boiler::set_ww_mode1(const char * value, const int8_t id) {
uint8_t set;
if (!Helpers::value2enum(value, set, FL_(enum_comfort1))) {
return false;
}
if (!is_fetch(EMS_TYPE_UBAParameterWWPlus)) {
return false;
}
if (set == 0) {
// LOG_INFO(F("Setting boiler dhw to High"));
} else if (set == 1) {
// LOG_INFO(F("Setting boiler dhw to Eco"));
set = 0xD8;
} else {
return false; // do nothing
}
write_command(EMS_TYPE_UBAParameterWWPlus, 13, set, EMS_TYPE_UBAParameterWWPlus);
return true;
return false;
}
// turn on/off dhw