mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-07 00:09:51 +03:00
added mqtt log
This commit is contained in:
101
src/ems-esp.cpp
101
src/ems-esp.cpp
@@ -67,8 +67,6 @@ Ticker showerColdShotStopTimer;
|
||||
#define SHOWER_COLDSHOT_DURATION 10 // in seconds. 10 seconds for cold water before turning back hot water
|
||||
#define SHOWER_MAX_DURATION 420000 // in ms. 7 minutes, before trigger a shot of cold water
|
||||
|
||||
#define MQTT_MAX_SIZE 700 // max size of a JSON object. See https://arduinojson.org/v6/assistant/
|
||||
|
||||
typedef struct {
|
||||
uint32_t timestamp; // for internal timings, via millis()
|
||||
uint8_t dallas_sensors; // count of dallas sensors
|
||||
@@ -508,7 +506,7 @@ void showInfo() {
|
||||
_renderIntValue("Burner current power", "%", EMS_Boiler.curBurnPow);
|
||||
_renderShortValue("Flame current", "uA", EMS_Boiler.flameCurr);
|
||||
_renderIntValue("System pressure", "bar", EMS_Boiler.sysPress, 10);
|
||||
if (EMS_Boiler.serviceCode == EMS_VALUE_SHORT_NOTSET) {
|
||||
if (EMS_Boiler.serviceCode == EMS_VALUE_USHORT_NOTSET) {
|
||||
myDebug_P(PSTR(" System service code: %s"), EMS_Boiler.serviceCodeChar);
|
||||
} else {
|
||||
myDebug_P(PSTR(" System service code: %s (%d)"), EMS_Boiler.serviceCodeChar, EMS_Boiler.serviceCode);
|
||||
@@ -688,16 +686,17 @@ void publishSensorValues() {
|
||||
// CRC check is done to see if there are changes in the values since the last send to avoid too much wifi traffic
|
||||
// a check is done against the previous values and if there are changes only then they are published. Unless force=true
|
||||
void publishValues(bool force) {
|
||||
// don't send if MQTT is connected
|
||||
// don't send if MQTT is not connected
|
||||
if (!myESP.isMQTTConnected()) {
|
||||
return;
|
||||
}
|
||||
|
||||
char s[20] = {0}; // for formatting strings
|
||||
StaticJsonDocument<MQTT_MAX_SIZE> doc;
|
||||
char data[MQTT_MAX_SIZE] = {0};
|
||||
CRC32 crc;
|
||||
uint32_t fchecksum;
|
||||
char s[20] = {0}; // for formatting strings
|
||||
StaticJsonDocument<MQTT_MAX_PAYLOAD_SIZE> doc;
|
||||
char data[MQTT_MAX_PAYLOAD_SIZE] = {0};
|
||||
CRC32 crc;
|
||||
uint32_t fchecksum;
|
||||
uint8_t jsonSize;
|
||||
|
||||
static uint8_t last_boilerActive = 0xFF; // for remembering last setting of the tap water or heating on/off
|
||||
static uint32_t previousBoilerPublishCRC = 0; // CRC check for boiler values
|
||||
@@ -769,22 +768,28 @@ void publishValues(bool force) {
|
||||
if (abs(EMS_Boiler.heatWorkMin) != EMS_VALUE_LONG_NOTSET)
|
||||
rootBoiler["heatWorkMin"] = (double)EMS_Boiler.heatWorkMin;
|
||||
|
||||
rootBoiler["ServiceCode"] = EMS_Boiler.serviceCodeChar;
|
||||
rootBoiler["ServiceCodeNumber"] = EMS_Boiler.serviceCode;
|
||||
if (EMS_Boiler.serviceCode != EMS_VALUE_USHORT_NOTSET) {
|
||||
rootBoiler["ServiceCode"] = EMS_Boiler.serviceCodeChar;
|
||||
rootBoiler["ServiceCodeNumber"] = EMS_Boiler.serviceCode;
|
||||
}
|
||||
|
||||
serializeJson(doc, data, sizeof(data));
|
||||
|
||||
// calculate hash and send values if something has changed, to save unnecessary wifi traffic
|
||||
for (size_t i = 0; i < measureJson(doc) - 1; i++) {
|
||||
crc.update(data[i]);
|
||||
}
|
||||
fchecksum = crc.finalize();
|
||||
if ((previousBoilerPublishCRC != fchecksum) || force) {
|
||||
previousBoilerPublishCRC = fchecksum;
|
||||
myDebugLog("Publishing boiler data via MQTT");
|
||||
// check for empty json
|
||||
jsonSize = measureJson(doc);
|
||||
if (jsonSize > 2) {
|
||||
// calculate hash and send values if something has changed, to save unnecessary wifi traffic
|
||||
for (uint8_t i = 0; i < (jsonSize - 1); i++) {
|
||||
crc.update(data[i]);
|
||||
}
|
||||
fchecksum = crc.finalize();
|
||||
if ((previousBoilerPublishCRC != fchecksum) || force) {
|
||||
previousBoilerPublishCRC = fchecksum;
|
||||
myDebugLog("Publishing boiler data via MQTT");
|
||||
|
||||
// send values via MQTT
|
||||
myESP.mqttPublish(TOPIC_BOILER_DATA, data);
|
||||
// send values via MQTT
|
||||
myESP.mqttPublish(TOPIC_BOILER_DATA, data);
|
||||
}
|
||||
}
|
||||
|
||||
// see if the heating or hot tap water has changed, if so send
|
||||
@@ -856,18 +861,22 @@ void publishValues(bool force) {
|
||||
data[0] = '\0'; // reset data for next package
|
||||
serializeJson(doc, data, sizeof(data));
|
||||
|
||||
// calculate new CRC
|
||||
crc.reset();
|
||||
for (size_t i = 0; i < measureJson(doc) - 1; i++) {
|
||||
crc.update(data[i]);
|
||||
}
|
||||
fchecksum = crc.finalize();
|
||||
if ((previousThermostatPublishCRC != fchecksum) || force) {
|
||||
previousThermostatPublishCRC = fchecksum;
|
||||
myDebugLog("Publishing thermostat data via MQTT");
|
||||
// check for empty json
|
||||
jsonSize = measureJson(doc);
|
||||
if (jsonSize > 2) {
|
||||
// calculate new CRC
|
||||
crc.reset();
|
||||
for (uint8_t i = 0; i < (jsonSize - 1); i++) {
|
||||
crc.update(data[i]);
|
||||
}
|
||||
fchecksum = crc.finalize();
|
||||
if ((previousThermostatPublishCRC != fchecksum) || force) {
|
||||
previousThermostatPublishCRC = fchecksum;
|
||||
myDebugLog("Publishing thermostat data via MQTT");
|
||||
|
||||
// send values via MQTT
|
||||
myESP.mqttPublish(TOPIC_THERMOSTAT_DATA, data);
|
||||
// send values via MQTT
|
||||
myESP.mqttPublish(TOPIC_THERMOSTAT_DATA, data);
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
@@ -906,18 +915,22 @@ void publishValues(bool force) {
|
||||
data[0] = '\0'; // reset data for next package
|
||||
serializeJson(doc, data, sizeof(data));
|
||||
|
||||
// calculate new CRC
|
||||
crc.reset();
|
||||
for (size_t i = 0; i < measureJson(doc) - 1; i++) {
|
||||
crc.update(data[i]);
|
||||
}
|
||||
fchecksum = crc.finalize();
|
||||
if ((previousSMPublishCRC != fchecksum) || force) {
|
||||
previousSMPublishCRC = fchecksum;
|
||||
myDebugLog("Publishing SM data via MQTT");
|
||||
// check for empty json
|
||||
jsonSize = measureJson(doc);
|
||||
if (jsonSize > 2) {
|
||||
// calculate new CRC
|
||||
crc.reset();
|
||||
for (uint8_t i = 0; i < (jsonSize - 1); i++) {
|
||||
crc.update(data[i]);
|
||||
}
|
||||
fchecksum = crc.finalize();
|
||||
if ((previousSMPublishCRC != fchecksum) || force) {
|
||||
previousSMPublishCRC = fchecksum;
|
||||
myDebugLog("Publishing SM data via MQTT");
|
||||
|
||||
// send values via MQTT
|
||||
myESP.mqttPublish(TOPIC_SM_DATA, data);
|
||||
// send values via MQTT
|
||||
myESP.mqttPublish(TOPIC_SM_DATA, data);
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
@@ -1675,7 +1688,7 @@ void WebCallback(JsonObject root) {
|
||||
|
||||
if (myESP.getUseSerial()) {
|
||||
emsbus["ok"] = false;
|
||||
emsbus["msg"] = "EMS Bus is disabled when in Serial mode. Check Settings->General Settings";
|
||||
emsbus["msg"] = "EMS Bus is disabled when in Serial mode. Check Settings->General Settings->Serial Port";
|
||||
} else {
|
||||
if (ems_getBusConnected()) {
|
||||
if (ems_getTxDisabled()) {
|
||||
|
||||
Reference in New Issue