@@ -514,10 +514,10 @@ void Boiler::check_active() {
|
|||||||
|
|
||||||
// 0x33
|
// 0x33
|
||||||
void Boiler::process_UBAParameterWW(std::shared_ptr<const Telegram> telegram) {
|
void Boiler::process_UBAParameterWW(std::shared_ptr<const Telegram> telegram) {
|
||||||
changed_ |= telegram->read_value(wWActivated_, 1); // 0xFF means on
|
changed_ |= telegram->read_value(wWActivated_, 1); // 0xFF means on
|
||||||
changed_ |= telegram->read_value(wWCircPump_, 6); // 0xFF means on
|
changed_ |= telegram->read_value(wWCircPump_, 6); // 0xFF means on
|
||||||
changed_ |= telegram->read_value(wWCircPumpMode_, 7); // 1=1x3min... 6=6x3min, 7=continuous
|
changed_ |= telegram->read_value(wWCircPumpMode_, 7); // 1=1x3min... 6=6x3min, 7=continuous
|
||||||
changed_ |= telegram->read_value(wWChargeType_, 10); // 0 = charge pump, 0xff = 3-way valve
|
changed_ |= telegram->read_value(wWChargeType_, 10); // 0 = charge pump, 0xff = 3-way valve
|
||||||
changed_ |= telegram->read_value(wWSelTemp_, 2);
|
changed_ |= telegram->read_value(wWSelTemp_, 2);
|
||||||
changed_ |= telegram->read_value(wWDisinfectTemp_, 8);
|
changed_ |= telegram->read_value(wWDisinfectTemp_, 8);
|
||||||
changed_ |= telegram->read_value(wWComfort_, 9);
|
changed_ |= telegram->read_value(wWComfort_, 9);
|
||||||
@@ -683,12 +683,11 @@ void Boiler::process_UBAParametersPlus(std::shared_ptr<const Telegram> telegram)
|
|||||||
|
|
||||||
// 0xEA
|
// 0xEA
|
||||||
void Boiler::process_UBAParameterWWPlus(std::shared_ptr<const Telegram> telegram) {
|
void Boiler::process_UBAParameterWWPlus(std::shared_ptr<const Telegram> telegram) {
|
||||||
changed_ |= telegram->read_value(wWActivated_, 5); // 0x01 means on
|
changed_ |= telegram->read_value(wWActivated_, 5); // 0x01 means on
|
||||||
changed_ |= telegram->read_value(wWCircPump_, 10); // 0x01 means yes
|
changed_ |= telegram->read_value(wWCircPump_, 10); // 0x01 means yes
|
||||||
changed_ |= telegram->read_value(wWCircPumpMode_, 11); // 1=1x3min... 6=6x3min, 7=continuous
|
changed_ |= telegram->read_value(wWCircPumpMode_, 11); // 1=1x3min... 6=6x3min, 7=continuous
|
||||||
// changed_ |= telegram->read_value(wWDisinfectTemp_, 12); // settings, status in E9
|
// changed_ |= telegram->read_value(wWDisinfectTemp_, 12); // settings, status in E9
|
||||||
// changed_ |= telegram->read_value(wWSelTemp_, 6); // settings, status in E9
|
// changed_ |= telegram->read_value(wWSelTemp_, 6); // settings, status in E9
|
||||||
|
|
||||||
}
|
}
|
||||||
|
|
||||||
// 0xE9 - DHW Status
|
// 0xE9 - DHW Status
|
||||||
@@ -801,7 +800,7 @@ void Boiler::set_flow_temp(const char * value, const int8_t id) {
|
|||||||
// set min boiler output
|
// set min boiler output
|
||||||
void Boiler::set_heating_activated(const char * value, const int8_t id) {
|
void Boiler::set_heating_activated(const char * value, const int8_t id) {
|
||||||
bool v = false;
|
bool v = false;
|
||||||
if (!Helpers::value2bool (value, v)) {
|
if (!Helpers::value2bool(value, v)) {
|
||||||