Merge pull request #3244 from proddy/dev

bump version for testing
This commit is contained in:
Proddy
2026-09-18 15:19:15 +02:00
committed by GitHub
4 changed files with 11 additions and 9 deletions
+6 -6
View File
@@ -2763,9 +2763,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/
"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpin3opt,input 3 options,string (>=0<=0), ,true,sensor.boiler_input_3_options,sensor.boiler_hpin3opt,6,0,1,198,8 "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpin3opt,input 3 options,string (>=0<=0), ,true,sensor.boiler_input_3_options,sensor.boiler_hpin3opt,6,0,1,198,8
"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpin4,input 4 state,boolean, ,false,binary_sensor.boiler_input_4_state,binary_sensor.boiler_hpin4,6,0,1,206,1 "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpin4,input 4 state,boolean, ,false,binary_sensor.boiler_input_4_state,binary_sensor.boiler_hpin4,6,0,1,206,1
"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpin4opt,input 4 options,string (>=0<=0), ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt,6,0,1,207,8 "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpin4opt,input 4 options,string (>=0<=0), ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt,6,0,1,207,8
"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,maxheatcomp,heat limit compressor,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] (>=0<=0), ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp,6,0,1,215,1 "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,maxheatcomp,heat limit compressor,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW\|12 kW\|15 kW] (>=0<=0), ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp,6,0,1,215,1
"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,maxheatheat,heat limit heating,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] (>=0<=0), ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat,6,0,1,216,1 "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,maxheatheat,heat limit heating,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW\|12 kW\|15 kW] (>=0<=0), ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat,6,0,1,216,1
"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,dhw.maxheat,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] (>=0<=0), ,true,select.boiler_dhw_heat_limit,select.boiler_dhw_maxheat,6,9,1,14,1 "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,dhw.maxheat,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW\|12 kW\|15 kW] (>=0<=0), ,true,select.boiler_dhw_heat_limit,select.boiler_dhw_maxheat,6,9,1,14,1
"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,auxheatersource,aux heater source,enum [not installed\|electric heater\|exclusive\|parallel\|hybrid] (>=0<=0), ,true,select.boiler_aux_heater_source,select.boiler_auxheatersource,6,0,1,217,1 "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,auxheatersource,aux heater source,enum [not installed\|electric heater\|exclusive\|parallel\|hybrid] (>=0<=0), ,true,select.boiler_aux_heater_source,select.boiler_auxheatersource,6,0,1,217,1
"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,pvcooling,cooling only with PV,boolean (>=0<=0), ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling,6,0,1,218,1 "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,pvcooling,cooling only with PV,boolean (>=0<=0), ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling,6,0,1,218,1
"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,auxheateronly,aux heater only,boolean (>=0<=0), ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly,6,0,1,219,1 "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,auxheateronly,aux heater only,boolean (>=0<=0), ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly,6,0,1,219,1
@@ -2982,9 +2982,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/
"Geo 5xx",boiler,173,hpin3opt,input 3 options,string (>=0<=0), ,true,sensor.boiler_input_3_options,sensor.boiler_hpin3opt,6,0,1,198,8 "Geo 5xx",boiler,173,hpin3opt,input 3 options,string (>=0<=0), ,true,sensor.boiler_input_3_options,sensor.boiler_hpin3opt,6,0,1,198,8
"Geo 5xx",boiler,173,hpin4,input 4 state,boolean, ,false,binary_sensor.boiler_input_4_state,binary_sensor.boiler_hpin4,6,0,1,206,1 "Geo 5xx",boiler,173,hpin4,input 4 state,boolean, ,false,binary_sensor.boiler_input_4_state,binary_sensor.boiler_hpin4,6,0,1,206,1
"Geo 5xx",boiler,173,hpin4opt,input 4 options,string (>=0<=0), ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt,6,0,1,207,8 "Geo 5xx",boiler,173,hpin4opt,input 4 options,string (>=0<=0), ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt,6,0,1,207,8
"Geo 5xx",boiler,173,maxheatcomp,heat limit compressor,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] (>=0<=0), ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp,6,0,1,215,1 "Geo 5xx",boiler,173,maxheatcomp,heat limit compressor,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW\|12 kW\|15 kW] (>=0<=0), ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp,6,0,1,215,1
"Geo 5xx",boiler,173,maxheatheat,heat limit heating,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] (>=0<=0), ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat,6,0,1,216,1 "Geo 5xx",boiler,173,maxheatheat,heat limit heating,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW\|12 kW\|15 kW] (>=0<=0), ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat,6,0,1,216,1
"Geo 5xx",boiler,173,dhw.maxheat,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] (>=0<=0), ,true,select.boiler_dhw_heat_limit,select.boiler_dhw_maxheat,6,9,1,14,1 "Geo 5xx",boiler,173,dhw.maxheat,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW\|12 kW\|15 kW] (>=0<=0), ,true,select.boiler_dhw_heat_limit,select.boiler_dhw_maxheat,6,9,1,14,1
"Geo 5xx",boiler,173,auxheatersource,aux heater source,enum [not installed\|electric heater\|exclusive\|parallel\|hybrid] (>=0<=0), ,true,select.boiler_aux_heater_source,select.boiler_auxheatersource,6,0,1,217,1 "Geo 5xx",boiler,173,auxheatersource,aux heater source,enum [not installed\|electric heater\|exclusive\|parallel\|hybrid] (>=0<=0), ,true,select.boiler_aux_heater_source,select.boiler_auxheatersource,6,0,1,217,1
"Geo 5xx",boiler,173,pvcooling,cooling only with PV,boolean (>=0<=0), ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling,6,0,1,218,1 "Geo 5xx",boiler,173,pvcooling,cooling only with PV,boolean (>=0<=0), ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling,6,0,1,218,1
"Geo 5xx",boiler,173,auxheateronly,aux heater only,boolean (>=0<=0), ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly,6,0,1,219,1 "Geo 5xx",boiler,173,auxheateronly,aux heater only,boolean (>=0<=0), ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly,6,0,1,219,1
Can't render this file because it is too large.
+3 -1
View File
@@ -1131,7 +1131,9 @@ void System::show_system(uuid::console::Shell & shell) {
// client and all the JSON work on this task, and a TLS handshake alone can want several KB // client and all the JSON work on this task, and a TLS handshake alone can want several KB
TaskHandle_t loop_task = xTaskGetHandle("loopTask"); TaskHandle_t loop_task = xTaskGetHandle("loopTask");
if (loop_task != nullptr) { if (loop_task != nullptr) {
shell.printfln(" Loop task stack min free/total: %u / %u bytes", (unsigned)uxTaskGetStackHighWaterMark(loop_task), (unsigned)getArduinoLoopTaskStackSize()); shell.printfln(" Loop task stack min free/total: %u / %u bytes",
(unsigned)uxTaskGetStackHighWaterMark(loop_task),
(unsigned)getArduinoLoopTaskStackSize());
} }
#endif #endif
shell.printfln(" App used/free: %lu KB / %lu KB", appUsed(), appFree()); shell.printfln(" App used/free: %lu KB / %lu KB", appUsed(), appFree());
+1 -1
View File
@@ -1 +1 @@
#define EMSESP_APP_VERSION "3.9.0-dev.10" #define EMSESP_APP_VERSION "3.9.0-dev.11"