Merge remote-tracking branch 'origin/dev' into idf4_no_master

This commit is contained in:
MichaelDvP
2022-05-21 11:36:08 +02:00
2 changed files with 57 additions and 33 deletions

View File

@@ -424,6 +424,15 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
MAKE_CF_CB(set_ww_maxpower),
0,
130);
register_device_value(DeviceValueTAG::TAG_BOILER_DATA_WW,
&wwMaxTemp_,
DeviceValueType::UINT,
nullptr,
FL_(wwMaxTemp),
DeviceValueUOM::DEGREES,
MAKE_CF_CB(set_ww_maxtemp),
0,
70);
register_device_value(DeviceValueTAG::TAG_BOILER_DATA_WW,
&wwCircPump_,
DeviceValueType::BOOL,
@@ -794,6 +803,7 @@ void Boiler::process_UBAParameterWWPlus(std::shared_ptr<const Telegram> telegram
has_update(telegram, wwDisinfectionTemp_, 12); // setting here, status in E9
has_update(telegram, wwSelTempSingle_, 16);
has_update(telegram, wwSelTempLow_, 18);
has_update(telegram, wwMaxTemp_, 20);
has_update(telegram, wwChargeOptimization_, 25);
uint8_t wwComfort1 = EMS_VALUE_UINT_NOTSET;
@@ -1411,6 +1421,18 @@ bool Boiler::set_ww_maxpower(const char * value, const int8_t id) {
return true;
}
// set dhw maximum temperature
bool Boiler::set_ww_maxtemp(const char * value, const int8_t id) {
int v = 0;
if (!Helpers::value2number(value, v)) {
return false;
}
write_command(EMS_TYPE_UBAParameterWWPlus, 20, v, EMS_TYPE_UBAParameterWWPlus);
return true;
}
// set min pump modulation
bool Boiler::set_min_pump(const char * value, const int8_t id) {
int v = 0;