From b6659b8586c9b53ca614b4593c67e7410764bbff Mon Sep 17 00:00:00 2001 From: proddy Date: Fri, 28 Mar 2025 17:22:20 +0100 Subject: [PATCH] auto-generate --- docs/Modbus-Entity-Registers.md | 6 +++--- docs/dump_entities.csv | 6 +++--- docs/dump_telegrams.csv | 10 +++++----- 3 files changed, 11 insertions(+), 11 deletions(-) diff --git a/docs/Modbus-Entity-Registers.md b/docs/Modbus-Entity-Registers.md index 7dbc4e734..07571758e 100644 --- a/docs/Modbus-Entity-Registers.md +++ b/docs/Modbus-Entity-Registers.md @@ -377,7 +377,7 @@ | maxheatcomp | heat limit compressor | enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] | | true | DEVICE_DATA | 206 | 1 | 1 | | maxheatheat | heat limit heating | enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] | | true | DEVICE_DATA | 207 | 1 | 1 | | dhw.maxheat | heat limit | enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] | | true | DHW | 14 | 1 | 1 | -| mandefrost | manual defrost | boolean | | true | DEVICE_DATA | 208 | 1 | 1 | +| auxheatersource | aux heater source | enum [not installed\|electric heater\|exclusive\|parallel\|hybrid] | | true | DEVICE_DATA | 208 | 1 | 1 | | pvcooling | cooling only with PV | boolean | | true | DEVICE_DATA | 209 | 1 | 1 | | auxheateronly | aux heater only | boolean | | true | DEVICE_DATA | 210 | 1 | 1 | | auxheateroff | disable aux heater | boolean | | true | DEVICE_DATA | 211 | 1 | 1 | @@ -1532,7 +1532,7 @@ | maxheatcomp | heat limit compressor | enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] | | true | DEVICE_DATA | 206 | 1 | 1 | | maxheatheat | heat limit heating | enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] | | true | DEVICE_DATA | 207 | 1 | 1 | | dhw.maxheat | heat limit | enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] | | true | DHW | 14 | 1 | 1 | -| mandefrost | manual defrost | boolean | | true | DEVICE_DATA | 208 | 1 | 1 | +| auxheatersource | aux heater source | enum [not installed\|electric heater\|exclusive\|parallel\|hybrid] | | true | DEVICE_DATA | 208 | 1 | 1 | | pvcooling | cooling only with PV | boolean | | true | DEVICE_DATA | 209 | 1 | 1 | | auxheateronly | aux heater only | boolean | | true | DEVICE_DATA | 210 | 1 | 1 | | auxheateroff | disable aux heater | boolean | | true | DEVICE_DATA | 211 | 1 | 1 | @@ -2097,7 +2097,7 @@ | maxheatcomp | heat limit compressor | enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] | | true | DEVICE_DATA | 206 | 1 | 1 | | maxheatheat | heat limit heating | enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] | | true | DEVICE_DATA | 207 | 1 | 1 | | dhw.maxheat | heat limit | enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] | | true | DHW | 14 | 1 | 1 | -| mandefrost | manual defrost | boolean | | true | DEVICE_DATA | 208 | 1 | 1 | +| auxheatersource | aux heater source | enum [not installed\|electric heater\|exclusive\|parallel\|hybrid] | | true | DEVICE_DATA | 208 | 1 | 1 | | pvcooling | cooling only with PV | boolean | | true | DEVICE_DATA | 209 | 1 | 1 | | auxheateronly | aux heater only | boolean | | true | DEVICE_DATA | 210 | 1 | 1 | | auxheateroff | disable aux heater | boolean | | true | DEVICE_DATA | 211 | 1 | 1 | diff --git a/docs/dump_entities.csv b/docs/dump_entities.csv index 25072615f..0a1ff02d6 100644 --- a/docs/dump_entities.csv +++ b/docs/dump_entities.csv @@ -118,7 +118,7 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "CS*800i, Logatherm WLW*",boiler,8,maxheatcomp,heat limit compressor,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp,5,0,1,206,1 "CS*800i, Logatherm WLW*",boiler,8,maxheatheat,heat limit heating,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat,5,0,1,207,1 "CS*800i, Logatherm WLW*",boiler,8,dhw.maxheat,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_dhw_heat_limit,select.boiler_dhw_maxheat,5,9,1,14,1 -"CS*800i, Logatherm WLW*",boiler,8,mandefrost,manual defrost,boolean, ,true,switch.boiler_manual_defrost,switch.boiler_mandefrost,5,0,1,208,1 +"CS*800i, Logatherm WLW*",boiler,8,auxheatersource,aux heater source,enum [not installed\|electric heater\|exclusive\|parallel\|hybrid], ,true,select.boiler_aux_heater_source,select.boiler_auxheatersource,5,0,1,208,1 "CS*800i, Logatherm WLW*",boiler,8,pvcooling,cooling only with PV,boolean, ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling,5,0,1,209,1 "CS*800i, Logatherm WLW*",boiler,8,auxheateronly,aux heater only,boolean, ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly,5,0,1,210,1 "CS*800i, Logatherm WLW*",boiler,8,auxheateroff,disable aux heater,boolean, ,true,switch.boiler_disable_aux_heater,switch.boiler_auxheateroff,5,0,1,211,1 @@ -2377,7 +2377,7 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,maxheatcomp,heat limit compressor,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp,5,0,1,206,1 "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,maxheatheat,heat limit heating,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat,5,0,1,207,1 "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,dhw.maxheat,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_dhw_heat_limit,select.boiler_dhw_maxheat,5,9,1,14,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,mandefrost,manual defrost,boolean, ,true,switch.boiler_manual_defrost,switch.boiler_mandefrost,5,0,1,208,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,auxheatersource,aux heater source,enum [not installed\|electric heater\|exclusive\|parallel\|hybrid], ,true,select.boiler_aux_heater_source,select.boiler_auxheatersource,5,0,1,208,1 "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,pvcooling,cooling only with PV,boolean, ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling,5,0,1,209,1 "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,auxheateronly,aux heater only,boolean, ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly,5,0,1,210,1 "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,auxheateroff,disable aux heater,boolean, ,true,switch.boiler_disable_aux_heater,switch.boiler_auxheateroff,5,0,1,211,1 @@ -2584,7 +2584,7 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Geo 5xx",boiler,173,maxheatcomp,heat limit compressor,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp,5,0,1,206,1 "Geo 5xx",boiler,173,maxheatheat,heat limit heating,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat,5,0,1,207,1 "Geo 5xx",boiler,173,dhw.maxheat,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_dhw_heat_limit,select.boiler_dhw_maxheat,5,9,1,14,1 -"Geo 5xx",boiler,173,mandefrost,manual defrost,boolean, ,true,switch.boiler_manual_defrost,switch.boiler_mandefrost,5,0,1,208,1 +"Geo 5xx",boiler,173,auxheatersource,aux heater source,enum [not installed\|electric heater\|exclusive\|parallel\|hybrid], ,true,select.boiler_aux_heater_source,select.boiler_auxheatersource,5,0,1,208,1 "Geo 5xx",boiler,173,pvcooling,cooling only with PV,boolean, ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling,5,0,1,209,1 "Geo 5xx",boiler,173,auxheateronly,aux heater only,boolean, ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly,5,0,1,210,1 "Geo 5xx",boiler,173,auxheateroff,disable aux heater,boolean, ,true,switch.boiler_disable_aux_heater,switch.boiler_auxheateroff,5,0,1,211,1 diff --git a/docs/dump_telegrams.csv b/docs/dump_telegrams.csv index 5667e3f72..6de36b5b4 100644 --- a/docs/dump_telegrams.csv +++ b/docs/dump_telegrams.csv @@ -13,7 +13,7 @@ telegram_type_id,name,is_fetched 0x19,UBAMonitorSlow, 0x1A,UBASetPoints, 0x1C,UBAMaintenanceStatus, -0x1E,HydrTemp, +0x1E,WM10TempMessage, 0x23,JunkersSetMixer,fetched 0x26,UBASettingsWW,fetched 0x28,WeatherComp,fetched @@ -109,10 +109,10 @@ telegram_type_id,name,is_fetched 0x02A0,RC300Curves, 0x02A1,RC300Curves, 0x02A2,RC300Curves, -0x02A5,CRFMonitor, +0x02A5,RC300Monitor,fetched 0x02A6,RC300Monitor, -0x02A7,RC300Monitor, -0x02A8,CRFMonitor, +0x02A7,CRFMonitor, +0x02A8,RC300Monitor, 0x02A9,RC300Monitor, 0x02AA,RC300Monitor, 0x02AB,RC300Monitor, @@ -133,7 +133,7 @@ telegram_type_id,name,is_fetched 0x02BE,RC300Set, 0x02BF,RC300Set, 0x02C0,RC300Set, -0x02CC,RC300Set2, +0x02CC,HPPressure,fetched 0x02CD,MMPLUSConfigMessage,fetched 0x02CE,RC300Set2, 0x02D0,RC300Set2,