@@ -28,7 +28,7 @@
|
||||
// timers, all values are in seconds
|
||||
#define PUBLISHVALUES_TIME 300 // every 5 mins post HA values
|
||||
#define SYSTEMCHECK_TIME 10 // every 10 seconds check if Boiler is online and execute other requests
|
||||
#define REGULARUPDATES_TIME 60 // every minute a call is made
|
||||
#define REGULARUPDATES_TIME 60 // every minute a call is made, so for our 2 calls theres a write cmd every 30seconds
|
||||
#define HEARTBEAT_TIME 1 // every second blink heartbeat LED
|
||||
Ticker publishValuesTimer;
|
||||
Ticker systemCheckTimer;
|
||||
@@ -58,9 +58,9 @@ uint8_t regularUpdatesCount = 0;
|
||||
"* x [n] experimental (warning: for debugging only!)"
|
||||
|
||||
// GPIOs
|
||||
#define LED_RX D1 // (GPIO5 on nodemcu)
|
||||
#define LED_TX D2 // (GPIO4 on nodemcu)
|
||||
#define LED_ERR D3 // (GPIO0 on nodemcu)
|
||||
#define LED_RX D1 // GPIO5
|
||||
#define LED_TX D2 // GPIO4
|
||||
#define LED_ERR D3 // GPIO0
|
||||
#define LED_HEARTBEAT LED_BUILTIN // onboard LED
|
||||
|
||||
// hostname is also used as the MQTT topic identifier (home/<hostname>)
|
||||
@@ -265,12 +265,13 @@ void showInfo() {
|
||||
((Boiler_Status.shower_timer) ? "enabled" : "disabled"),
|
||||
((Boiler_Status.shower_alert) ? "enabled" : "disabled"));
|
||||
|
||||
myDebug(" EMS Bus Stats: RxPgks=%d, TxPkgs=%d, #CrcErrors=%d, ",
|
||||
myDebug(" EMS Bus Stats: Connected=%s, # Rx telegrams=%d, # Tx telegrams=%d, # Crc Errors=%d, ",
|
||||
(Boiler_Status.boiler_online ? "yes" : "no"),
|
||||
EMS_Sys_Status.emsRxPgks,
|
||||
EMS_Sys_Status.emsTxPkgs,
|
||||
EMS_Sys_Status.emxCrcErr);
|
||||
|
||||
myDebug("RxStatus=");
|
||||
myDebug("Rx Status=");
|
||||
switch (EMS_Sys_Status.emsRxStatus) {
|
||||
case EMS_RX_IDLE:
|
||||
myDebug("idle");
|
||||
@@ -280,7 +281,7 @@ void showInfo() {
|
||||
break;
|
||||
}
|
||||
|
||||
myDebug(", TxStatus=");
|
||||
myDebug(", Tx Status=");
|
||||
switch (EMS_Sys_Status.emsTxStatus) {
|
||||
case EMS_TX_IDLE:
|
||||
myDebug("idle");
|
||||
@@ -293,7 +294,7 @@ void showInfo() {
|
||||
break;
|
||||
}
|
||||
|
||||
myDebug(", TxAction=");
|
||||
myDebug(", Last Tx Action=");
|
||||
switch (EMS_TxTelegram.action) {
|
||||
case EMS_TX_READ:
|
||||
myDebug("read");
|
||||
@@ -453,7 +454,7 @@ void publishValues() {
|
||||
} else if (EMS_Thermostat.mode == 1) {
|
||||
myESP.publish(TOPIC_THERMOSTAT_MODE, "manual");
|
||||
} else {
|
||||
myESP.publish(TOPIC_THERMOSTAT_MODE, "auto");
|
||||
myESP.publish(TOPIC_THERMOSTAT_MODE, "auto"); // must be auto
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -627,8 +628,10 @@ void updateHeartbeat() {
|
||||
heartbeatEnabled = true;
|
||||
} else {
|
||||
heartbeatEnabled = false;
|
||||
#ifdef USE_LED
|
||||
// ...and turn off LED
|
||||
digitalWrite(LED_HEARTBEAT, HIGH);
|
||||
#endif
|
||||
}
|
||||
}
|
||||
|
||||
@@ -728,8 +731,10 @@ void showLEDs() {
|
||||
// heartbeat callback to light up the LED, called via Ticker
|
||||
void heartbeat() {
|
||||
if (heartbeatEnabled) {
|
||||
#ifdef USE_LED
|
||||
int state = digitalRead(LED_HEARTBEAT);
|
||||
digitalWrite(LED_HEARTBEAT, !state);
|
||||
#endif
|
||||
}
|
||||
}
|
||||
|
||||
@@ -738,7 +743,7 @@ void systemCheck() {
|
||||
// first do a system check to see if there is still a connection to the EMS
|
||||
Boiler_Status.boiler_online = ((timestamp - EMS_Sys_Status.emsLastPoll) < POLL_TIMEOUT_ERR);
|
||||
if (!Boiler_Status.boiler_online) {
|
||||
myDebug("Error! Boiler unreachable. Please check connection. Retrying in 10 seconds.\n");
|
||||
myDebug("Error! Unable to connect to EMS bus. Please check connections. Retry in 10 seconds...\n");
|
||||
}
|
||||
}
|
||||
|
||||
@@ -748,11 +753,14 @@ void systemCheck() {
|
||||
void regularUpdates() {
|
||||
uint8_t cycle = (regularUpdatesCount++ % MAX_MANUAL_CALLS);
|
||||
|
||||
// only do calls if the EMS is connected and alive
|
||||
if (Boiler_Status.boiler_online) {
|
||||
if ((cycle == 0) && Boiler_Status.thermostat_enabled) {
|
||||
ems_doReadCommand(EMS_TYPE_RC20Temperature); // to force get the thermostat mode which is not broadcasted
|
||||
} else if (cycle == 1) {
|
||||
ems_doReadCommand(EMS_TYPE_UBAParameterWW); // get Warm Water values
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
// turn off hot water to send a shot of cold
|
||||
@@ -794,9 +802,6 @@ void loop() {
|
||||
// if first time connected to MQTT, send welcome start message
|
||||
// which will send all the state values from HA back to the clock via MQTT and return the boottime
|
||||
if ((!startMQTTsent) && (connectionStatus == FULL_CONNECTION)) {
|
||||
// now that we're connected lets get some data from the EMS
|
||||
ems_doReadCommand(EMS_TYPE_UBAParameterWW);
|
||||
|
||||
myESP.sendStart();
|
||||
startMQTTsent = true;
|
||||
|
||||
@@ -804,8 +809,13 @@ void loop() {
|
||||
myESP.publish(TOPIC_SHOWER_TIMER, Boiler_Status.shower_timer ? "1" : "0");
|
||||
myESP.publish(TOPIC_SHOWER_ALERT, Boiler_Status.shower_alert ? "1" : "0");
|
||||
|
||||
// make sure warm water if activated, in case it got stuck with the shower alert
|
||||
ems_setWarmWaterActivated(true);
|
||||
if (Boiler_Status.boiler_online) {
|
||||
// now that we're connected lets get some data from the EMS
|
||||
ems_doReadCommand(EMS_TYPE_UBAParameterWW);
|
||||
ems_setWarmWaterActivated(true); // make sure warm water if activated, in case it got stuck with the shower alert
|
||||
} else {
|
||||
myDebugLog("Boot: can't connect to EMS.");
|
||||
}
|
||||
}
|
||||
|
||||
// if we received new data and flagged for pushing, do it
|
||||
|
||||