summery over last commitsto MM10

- add MM200 warm water circuits (#299)
- add terminal boiler wwactive on/off command (#301)
- show first active thermostat hc in web (instead always 1)
- add log d [id] to show messages from/to specific ID (may replace log t and log s)
- add mixer version to info
- add warm water circulation active to terminal and mqtt
- mqtt subscribe only to active hc
- change NOTSET values for short/ushort and set the compare to level (match 0x7D00, 0x8000 and 0x8300 as notset)
- add calculated flow temperature to thermostat stats
This commit is contained in:
MichaelDvP
2020-01-18 19:12:53 +01:00
parent 9343132820
commit b950cf8246
5 changed files with 122 additions and 27 deletions

View File

@@ -34,6 +34,7 @@
// thermostat specific
#define EMS_THERMOSTAT_MAXHC 4 // max number of heating circuits
#define EMS_THERMOSTAT_MAXWWC 2 // max number of warm water circuits
#define EMS_THERMOSTAT_DEFAULTHC 1 // default heating circuit is 1
#define EMS_THERMOSTAT_WRITE_YES true
#define EMS_THERMOSTAT_WRITE_NO false
@@ -112,9 +113,10 @@ typedef enum {
EMS_SYS_LOGGING_WATCH, // watch a specific type ID
EMS_SYS_LOGGING_BASIC, // only basic read/write messages
EMS_SYS_LOGGING_THERMOSTAT, // only telegrams sent from thermostat
EMS_SYS_LOGGING_SOLARMODULE, // only telegrams sent from thermostat
EMS_SYS_LOGGING_SOLARMODULE, // only telegrams sent from solarmodule
EMS_SYS_LOGGING_VERBOSE, // everything
EMS_SYS_LOGGING_JABBER // lots of debug output...
EMS_SYS_LOGGING_JABBER, // lots of debug output...
EMS_SYS_LOGGING_DEVICE // watch the device ID
} _EMS_SYS_LOGGING;
// status/counters since last power on
@@ -126,7 +128,7 @@ typedef struct {
uint16_t emxCrcErr; // CRC errors
bool emsPollEnabled; // flag enable the response to poll messages
_EMS_SYS_LOGGING emsLogging; // logging
uint16_t emsLogging_typeID; // the typeID to watch
uint16_t emsLogging_ID; // the type or device ID to watch
uint8_t emsRefreshedFlags; // fresh data, needs to be pushed out to MQTT
bool emsBusConnected; // is there an active bus
uint32_t emsRxTimestamp; // timestamp of last EMS message received
@@ -344,6 +346,15 @@ typedef struct {
uint8_t flowSetTemp;
} _EMS_Mixing_HC;
// Mixing Module per WWC
typedef struct {
uint8_t wwc; // warm water circuit 1, 2
bool active; // true if there is data for this WWC
uint16_t flowTemp;
uint8_t pumpMod;
uint8_t tempStatus;
} _EMS_Mixing_WWC;
// Mixer data
typedef struct {
uint8_t device_id;
@@ -353,6 +364,7 @@ typedef struct {
char version[10];
bool detected;
_EMS_Mixing_HC hc[EMS_THERMOSTAT_MAXHC]; // array for the 4 heating circuits
_EMS_Mixing_WWC wwc[EMS_THERMOSTAT_MAXWWC]; // array for the 2 ww circuits
} _EMS_Mixing;