mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-07 00:09:51 +03:00
summery over last commitsto MM10
- add MM200 warm water circuits (#299) - add terminal boiler wwactive on/off command (#301) - show first active thermostat hc in web (instead always 1) - add log d [id] to show messages from/to specific ID (may replace log t and log s) - add mixer version to info - add warm water circulation active to terminal and mqtt - mqtt subscribe only to active hc - change NOTSET values for short/ushort and set the compare to level (match 0x7D00, 0x8000 and 0x8300 as notset) - add calculated flow temperature to thermostat stats
This commit is contained in:
@@ -103,7 +103,7 @@ static const command_t project_cmds[] PROGMEM = {
|
||||
{true, "master_thermostat [product id]", "set default thermostat to use. Omit [product id] to show options."},
|
||||
|
||||
{false, "info", "show current values deciphered from the EMS messages"},
|
||||
{false, "log <n | b | t | s | r | j | v | w [type ID]", "set logging to none, basic, thermostat, solar module, raw, jabber, verbose or watch a specific type"},
|
||||
{false, "log <n | b | t | s | r | j | v | w [ID] | d [ID]>", "logging: none, basic, thermo, solar, raw, jabber, verbose, watch a type or device"},
|
||||
|
||||
#ifdef TESTS
|
||||
{false, "test <n>", "insert a test telegram on to the EMS bus"},
|
||||
@@ -120,6 +120,7 @@ static const command_t project_cmds[] PROGMEM = {
|
||||
{false, "thermostat mode [hc] <mode>", "set mode (0=off, 1=manual, 2=auto) for heating circuit hc 1-4"},
|
||||
{false, "boiler read <type ID>", "send read request to boiler"},
|
||||
{false, "boiler wwtemp <degrees>", "set boiler warm water temperature"},
|
||||
{false, "boiler wwactive <on | off>", "set boiler warm water on/off"},
|
||||
{false, "boiler tapwater <on | off>", "set boiler warm tap water on/off"},
|
||||
{false, "boiler flowtemp <degrees>", "set boiler flow temperature"},
|
||||
{false, "boiler comfort <hot | eco | intelligent>", "set boiler warm water comfort setting"}
|
||||
@@ -232,6 +233,8 @@ void showInfo() {
|
||||
myDebug_P(PSTR(" System logging set to Jabber"));
|
||||
} else if (sysLog == EMS_SYS_LOGGING_WATCH) {
|
||||
myDebug_P(PSTR(" System logging set to Watch"));
|
||||
} else if (sysLog == EMS_SYS_LOGGING_DEVICE) {
|
||||
myDebug_P(PSTR(" System logging set to device"));
|
||||
} else {
|
||||
myDebug_P(PSTR(" System logging set to None"));
|
||||
}
|
||||
@@ -481,7 +484,7 @@ void showInfo() {
|
||||
myDebug_P(PSTR("%sMixing module stats:%s"), COLOR_BOLD_ON, COLOR_BOLD_OFF);
|
||||
myDebug_P(PSTR(" Mixing: %s"), ems_getDeviceDescription(EMS_DEVICE_TYPE_MIXING, buffer_type,false));
|
||||
if (EMS_Boiler.switchTemp < EMS_VALUE_USHORT_NOTSET)
|
||||
_renderShortValue("Switch temperature", "C", EMS_Boiler.switchTemp);
|
||||
_renderUShortValue("Switch temperature", "C", EMS_Boiler.switchTemp);
|
||||
|
||||
for (uint8_t hc_num = 1; hc_num <= EMS_THERMOSTAT_MAXHC; hc_num++) {
|
||||
if (EMS_Mixing.hc[hc_num - 1].active) {
|
||||
@@ -496,6 +499,17 @@ void showInfo() {
|
||||
_renderIntValue(" Current valve status", "", EMS_Mixing.hc[hc_num - 1].valveStatus);
|
||||
}
|
||||
}
|
||||
for (uint8_t wwc_num = 1; wwc_num <= EMS_THERMOSTAT_MAXWWC; wwc_num++) {
|
||||
if (EMS_Mixing.wwc[wwc_num - 1].active) {
|
||||
myDebug_P(PSTR(" Warm Water Buffer %d"), wwc_num);
|
||||
if (EMS_Mixing.wwc[wwc_num - 1].flowTemp < EMS_VALUE_USHORT_NOTSET)
|
||||
_renderUShortValue(" Current warm water temperature", "C", EMS_Mixing.wwc[wwc_num - 1].flowTemp);
|
||||
if (EMS_Mixing.wwc[wwc_num - 1].pumpMod != EMS_VALUE_INT_NOTSET)
|
||||
_renderIntValue(" Current pump status", "", EMS_Mixing.wwc[wwc_num - 1].pumpMod);
|
||||
if (EMS_Mixing.wwc[wwc_num - 1].tempStatus != EMS_VALUE_INT_NOTSET)
|
||||
_renderIntValue(" Current temp status", "", EMS_Mixing.wwc[wwc_num - 1].tempStatus);
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
// Dallas external temp sensors
|
||||
@@ -777,7 +791,6 @@ void publishEMSValues(bool force) {
|
||||
strlcpy(hc, THERMOSTAT_HC, sizeof(hc));
|
||||
strlcat(hc, _int_to_char(s, mixing->hc), sizeof(hc));
|
||||
JsonObject dataMixing = rootMixing.createNestedObject(hc);
|
||||
|
||||
if (mixing->flowTemp < EMS_VALUE_USHORT_NOTSET)
|
||||
dataMixing["flowTemp"] = (float)mixing->flowTemp / 10;
|
||||
if (mixing->flowSetTemp != EMS_VALUE_INT_NOTSET)
|
||||
@@ -788,6 +801,23 @@ void publishEMSValues(bool force) {
|
||||
dataMixing["valveStatus"] = mixing->valveStatus;
|
||||
}
|
||||
}
|
||||
for (uint8_t wwc_v = 1; wwc_v <= EMS_THERMOSTAT_MAXWWC; wwc_v++) {
|
||||
_EMS_Mixing_WWC * mixing = &EMS_Mixing.wwc[wwc_v - 1];
|
||||
// only send if we have an active Warm water Circuit with real data
|
||||
if (mixing->active) {
|
||||
// build new json object
|
||||
char wwc[10]; // wc{1-2}
|
||||
strlcpy(wwc, "wwc", sizeof(wwc));
|
||||
strlcat(wwc, _int_to_char(s, mixing->wwc), sizeof(wwc));
|
||||
JsonObject dataMixing = rootMixing.createNestedObject(wwc);
|
||||
if (mixing->flowTemp < EMS_VALUE_USHORT_NOTSET)
|
||||
dataMixing["wwTemp"] = (float)mixing->flowTemp / 10;
|
||||
if (mixing->pumpMod != EMS_VALUE_INT_NOTSET)
|
||||
dataMixing["pumpStatus"] = mixing->pumpMod;
|
||||
if (mixing->tempStatus != EMS_VALUE_INT_NOTSET)
|
||||
dataMixing["tempStatus"] = mixing->tempStatus;
|
||||
}
|
||||
}
|
||||
|
||||
data[0] = '\0'; // reset data for next package
|
||||
serializeJson(doc, data, sizeof(data));
|
||||
@@ -1276,6 +1306,9 @@ void TelnetCommandCallback(uint8_t wc, const char * commandLine) {
|
||||
} else if ((strcmp(second_cmd, "w") == 0) && (wc == 3)) {
|
||||
ems_setLogging(EMS_SYS_LOGGING_WATCH, _readHexNumber()); // get type_id
|
||||
ok = true;
|
||||
} else if ((strcmp(second_cmd, "d") == 0) && (wc == 3)) {
|
||||
ems_setLogging(EMS_SYS_LOGGING_DEVICE, _readHexNumber()); // get device_id
|
||||
ok = true;
|
||||
}
|
||||
}
|
||||
|
||||
@@ -1335,6 +1368,15 @@ void TelnetCommandCallback(uint8_t wc, const char * commandLine) {
|
||||
} else if (strcmp(second_cmd, "flowtemp") == 0) {
|
||||
ems_setFlowTemp(_readIntNumber());
|
||||
ok = true;
|
||||
} else if (strcmp(second_cmd, "wwactive") == 0) {
|
||||
char * third_cmd = _readWord();
|
||||
if (strcmp(third_cmd, "on") == 0) {
|
||||
ems_setWarmWaterActivated(true);
|
||||
ok = true;
|
||||
} else if (strcmp(third_cmd, "off") == 0) {
|
||||
ems_setWarmWaterActivated(false);
|
||||
ok = true;
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
@@ -1403,13 +1445,16 @@ void MQTTCallback(unsigned int type, const char * topic, const char * message) {
|
||||
char topic_s[50];
|
||||
char buffer[4];
|
||||
for (uint8_t hc = 1; hc <= EMS_THERMOSTAT_MAXHC; hc++) {
|
||||
strlcpy(topic_s, TOPIC_THERMOSTAT_CMD_TEMP_HA, sizeof(topic_s));
|
||||
strlcat(topic_s, itoa(hc, buffer, 10), sizeof(topic_s));
|
||||
myESP.mqttSubscribe(topic_s);
|
||||
// subscribe onlyto active hc
|
||||
if(EMS_Thermostat.hc[hc - 1].active) {
|
||||
strlcpy(topic_s, TOPIC_THERMOSTAT_CMD_TEMP_HA, sizeof(topic_s));
|
||||
strlcat(topic_s, itoa(hc, buffer, 10), sizeof(topic_s));
|
||||
myESP.mqttSubscribe(topic_s);
|
||||
|
||||
strlcpy(topic_s, TOPIC_THERMOSTAT_CMD_MODE_HA, sizeof(topic_s));
|
||||
strlcat(topic_s, itoa(hc, buffer, 10), sizeof(topic_s));
|
||||
myESP.mqttSubscribe(topic_s);
|
||||
strlcpy(topic_s, TOPIC_THERMOSTAT_CMD_MODE_HA, sizeof(topic_s));
|
||||
strlcat(topic_s, itoa(hc, buffer, 10), sizeof(topic_s));
|
||||
myESP.mqttSubscribe(topic_s);
|
||||
}
|
||||
}
|
||||
|
||||
// generic incoming MQTT command for Thermostat
|
||||
@@ -1574,7 +1619,7 @@ void MQTTCallback(unsigned int type, const char * topic, const char * message) {
|
||||
uint8_t hc;
|
||||
// thermostat temp changes
|
||||
hc = _hasHCspecified(TOPIC_THERMOSTAT_CMD_TEMP_HA, topic);
|
||||
if (hc) {
|
||||
if (hc && EMS_Thermostat.hc[hc - 1].active) {
|
||||
float f = strtof((char *)message, 0);
|
||||
ems_setThermostatTemp(f, hc);
|
||||
publishEMSValues(true); // publish back immediately
|
||||
@@ -1583,7 +1628,7 @@ void MQTTCallback(unsigned int type, const char * topic, const char * message) {
|
||||
|
||||
// thermostat mode changes
|
||||
hc = _hasHCspecified(TOPIC_THERMOSTAT_CMD_MODE_HA, topic);
|
||||
if (hc) {
|
||||
if (hc && EMS_Thermostat.hc[hc - 1].active) {
|
||||
if (strncmp(message, "auto", 4) == 0) {
|
||||
ems_setThermostatMode(2, hc);
|
||||
} else if ((strncmp(message, "day", 4) == 0) || (strncmp(message, "manual", 6) == 0) || (strncmp(message, "heat", 4) == 0)) {
|
||||
@@ -1607,7 +1652,7 @@ void MQTTCallback(unsigned int type, const char * topic, const char * message) {
|
||||
|
||||
// thermostat temp changes
|
||||
hc = _hasHCspecified(TOPIC_THERMOSTAT_CMD_TEMP, command);
|
||||
if (hc) {
|
||||
if (hc && EMS_Thermostat.hc[hc - 1].active) {
|
||||
float f = doc["data"];
|
||||
ems_setThermostatTemp(f, hc);
|
||||
publishEMSValues(true); // publish back immediately
|
||||
@@ -1616,7 +1661,7 @@ void MQTTCallback(unsigned int type, const char * topic, const char * message) {
|
||||
|
||||
// thermostat mode changes
|
||||
hc = _hasHCspecified(TOPIC_THERMOSTAT_CMD_MODE, command);
|
||||
if (hc) {
|
||||
if (hc && EMS_Thermostat.hc[hc - 1].active) {
|
||||
const char * data_cmd = doc["data"];
|
||||
if (strncmp(data_cmd, "auto", 4) == 0) {
|
||||
ems_setThermostatMode(2, hc);
|
||||
@@ -1630,7 +1675,7 @@ void MQTTCallback(unsigned int type, const char * topic, const char * message) {
|
||||
|
||||
// set night temp value
|
||||
hc = _hasHCspecified(TOPIC_THERMOSTAT_CMD_NIGHTTEMP, command);
|
||||
if (hc) {
|
||||
if (hc && EMS_Thermostat.hc[hc - 1].active) {
|
||||
float f = doc["data"];
|
||||
ems_setThermostatTemp(f, hc, 1); // night
|
||||
return;
|
||||
@@ -1638,7 +1683,7 @@ void MQTTCallback(unsigned int type, const char * topic, const char * message) {
|
||||
|
||||
// set daytemp value
|
||||
hc = _hasHCspecified(TOPIC_THERMOSTAT_CMD_DAYTEMP, command);
|
||||
if (hc) {
|
||||
if (hc && EMS_Thermostat.hc[hc - 1].active) {
|
||||
float f = doc["data"];
|
||||
ems_setThermostatTemp(f, hc, 2); // day
|
||||
return;
|
||||
@@ -1646,7 +1691,7 @@ void MQTTCallback(unsigned int type, const char * topic, const char * message) {
|
||||
|
||||
// set holiday value
|
||||
hc = _hasHCspecified(TOPIC_THERMOSTAT_CMD_HOLIDAYTEMP, command);
|
||||
if (hc) {
|
||||
if (hc && EMS_Thermostat.hc[hc - 1].active) {
|
||||
float f = doc["data"];
|
||||
ems_setThermostatTemp(f, hc, 3); // holiday
|
||||
return;
|
||||
@@ -1727,7 +1772,7 @@ void WebCallback(JsonObject root) {
|
||||
|
||||
uint8_t hc_num = 1; // default to HC1
|
||||
uint8_t model = ems_getThermostatModel();
|
||||
while (hc_num <= EMS_THERMOSTAT_MAXHC && !EMS_Thermostat.hc[hc_num - 1].active) hc_num++;
|
||||
while (hc_num < EMS_THERMOSTAT_MAXHC && !EMS_Thermostat.hc[hc_num - 1].active) hc_num++; // first active hc
|
||||
// Render Current & Setpoint Room Temperature
|
||||
if (model == EMS_DEVICE_FLAG_EASY) {
|
||||
if (EMS_Thermostat.hc[hc_num - 1].setpoint_roomTemp > EMS_VALUE_SHORT_NOTSET)
|
||||
|
||||
41
src/ems.cpp
41
src/ems.cpp
@@ -128,6 +128,12 @@ void ems_init() {
|
||||
EMS_Mixing.hc[i].valveStatus = EMS_VALUE_INT_NOTSET;
|
||||
EMS_Mixing.hc[i].flowSetTemp = EMS_VALUE_INT_NOTSET;
|
||||
}
|
||||
for (uint8_t i = 0; i < EMS_THERMOSTAT_MAXWWC; i++) {
|
||||
EMS_Mixing.wwc[i].wwc = i + 1;
|
||||
EMS_Mixing.wwc[i].flowTemp = EMS_VALUE_USHORT_NOTSET;
|
||||
EMS_Mixing.wwc[i].pumpMod = EMS_VALUE_INT_NOTSET;
|
||||
EMS_Mixing.wwc[i].tempStatus = EMS_VALUE_INT_NOTSET;
|
||||
}
|
||||
|
||||
// UBAParameterWW
|
||||
EMS_Boiler.wWActivated = EMS_VALUE_BOOL_NOTSET; // Warm Water activated
|
||||
@@ -281,9 +287,9 @@ _EMS_SYS_LOGGING ems_getLogging() {
|
||||
return EMS_Sys_Status.emsLogging;
|
||||
}
|
||||
|
||||
void ems_setLogging(_EMS_SYS_LOGGING loglevel, uint16_t type_id) {
|
||||
EMS_Sys_Status.emsLogging_typeID = type_id;
|
||||
ems_setLogging(EMS_SYS_LOGGING_WATCH, false);
|
||||
void ems_setLogging(_EMS_SYS_LOGGING loglevel, uint16_t id) {
|
||||
EMS_Sys_Status.emsLogging_ID = id;
|
||||
ems_setLogging(loglevel, false);
|
||||
}
|
||||
|
||||
void ems_setLogging(_EMS_SYS_LOGGING loglevel, bool quiet) {
|
||||
@@ -309,6 +315,8 @@ void ems_setLogging(_EMS_SYS_LOGGING loglevel, bool quiet) {
|
||||
myDebug_P(PSTR("System Logging set to Jabber mode"));
|
||||
} else if (loglevel == EMS_SYS_LOGGING_WATCH) {
|
||||
myDebug_P(PSTR("System Logging set to Watch mode"));
|
||||
} else if (loglevel == EMS_SYS_LOGGING_DEVICE) {
|
||||
myDebug_P(PSTR("System Logging set to Device mode"));
|
||||
}
|
||||
}
|
||||
|
||||
@@ -850,8 +858,11 @@ void ems_parseTelegram(uint8_t * telegram, uint8_t length) {
|
||||
// but still continue to process it
|
||||
if ((EMS_Sys_Status.emsLogging == EMS_SYS_LOGGING_RAW)) {
|
||||
_debugPrintTelegram("", &EMS_RxTelegram, COLOR_WHITE, true);
|
||||
} else if ((EMS_Sys_Status.emsLogging == EMS_SYS_LOGGING_WATCH) && (EMS_RxTelegram.type == EMS_Sys_Status.emsLogging_typeID)) {
|
||||
} else if ((EMS_Sys_Status.emsLogging == EMS_SYS_LOGGING_WATCH) && (EMS_RxTelegram.type == EMS_Sys_Status.emsLogging_ID)) {
|
||||
_debugPrintTelegram("", &EMS_RxTelegram, COLOR_WHITE, true);
|
||||
// raw printout for log d [id] disabled, moved to _printMessage()
|
||||
// } else if ((EMS_Sys_Status.emsLogging == EMS_SYS_LOGGING_DEVICE) && ((EMS_RxTelegram.src == EMS_Sys_Status.emsLogging_ID) || (EMS_RxTelegram.dest == EMS_Sys_Status.emsLogging_ID))) {
|
||||
// _debugPrintTelegram("", &EMS_RxTelegram, COLOR_WHITE, true);
|
||||
}
|
||||
|
||||
// Assume at this point we have something that vaguely resembles a telegram in the format [src] [dest] [type] [offset] [data] [crc]
|
||||
@@ -929,6 +940,11 @@ void _printMessage(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
if ((src == EMS_SolarModule.device_id) || (dest == EMS_SolarModule.device_id)) {
|
||||
_debugPrintTelegram(output_str, EMS_RxTelegram, color_s);
|
||||
}
|
||||
} else if (EMS_Sys_Status.emsLogging == EMS_SYS_LOGGING_DEVICE) {
|
||||
// only print ones to/from DeviceID
|
||||
if ((src == EMS_Sys_Status.emsLogging_ID) || (dest == EMS_Sys_Status.emsLogging_ID)) {
|
||||
_debugPrintTelegram(output_str, EMS_RxTelegram, color_s);
|
||||
}
|
||||
} else {
|
||||
// always print
|
||||
_debugPrintTelegram(output_str, EMS_RxTelegram, color_s);
|
||||
@@ -1269,6 +1285,19 @@ void _process_MMPLUSStatusMessage(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
_setValue(EMS_RxTelegram, &EMS_Mixing.hc[hc].pumpMod, EMS_OFFSET_MMPLUSStatusMessage_pump_mod);
|
||||
_setValue(EMS_RxTelegram, &EMS_Mixing.hc[hc].valveStatus, EMS_OFFSET_MMPLUSStatusMessage_valve_status);
|
||||
}
|
||||
// Mixer warm water loading - 0x0231, 0x0232
|
||||
|
||||
void _process_MMPLUSStatusMessageWW(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
uint8_t wwc = (EMS_RxTelegram->type - EMS_TYPE_MMPLUSStatusMessage_WWC1); // 0 to 3
|
||||
if (wwc >= EMS_THERMOSTAT_MAXWWC) {
|
||||
return; // invalid type
|
||||
}
|
||||
EMS_Mixing.wwc[wwc].active = true;
|
||||
|
||||
_setValue(EMS_RxTelegram, &EMS_Mixing.wwc[wwc].flowTemp, EMS_OFFSET_MMPLUSStatusMessage_WW_flow_temp);
|
||||
_setValue(EMS_RxTelegram, &EMS_Mixing.wwc[wwc].pumpMod, EMS_OFFSET_MMPLUSStatusMessage_WW_pump_mod);
|
||||
_setValue(EMS_RxTelegram, &EMS_Mixing.wwc[wwc].tempStatus, EMS_OFFSET_MMPLUSStatusMessage_WW_temp_status);
|
||||
}
|
||||
|
||||
// Mixer - 0xAB
|
||||
void _process_MMStatusMessage(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
@@ -2859,6 +2888,10 @@ const _EMS_Type EMS_Types[] = {
|
||||
// Mixing devices MM10 - MM400
|
||||
{EMS_DEVICE_UPDATE_FLAG_MIXING, EMS_TYPE_MMPLUSStatusMessage_HC1, "MMPLUSStatusMessage_HC1", _process_MMPLUSStatusMessage},
|
||||
{EMS_DEVICE_UPDATE_FLAG_MIXING, EMS_TYPE_MMPLUSStatusMessage_HC2, "MMPLUSStatusMessage_HC2", _process_MMPLUSStatusMessage},
|
||||
{EMS_DEVICE_UPDATE_FLAG_MIXING, EMS_TYPE_MMPLUSStatusMessage_HC3, "MMPLUSStatusMessage_HC3", _process_MMPLUSStatusMessage},
|
||||
{EMS_DEVICE_UPDATE_FLAG_MIXING, EMS_TYPE_MMPLUSStatusMessage_HC4, "MMPLUSStatusMessage_HC4", _process_MMPLUSStatusMessage},
|
||||
{EMS_DEVICE_UPDATE_FLAG_MIXING, EMS_TYPE_MMPLUSStatusMessage_WWC1, "MMPLUSStatusMessage_WWC1", _process_MMPLUSStatusMessageWW},
|
||||
{EMS_DEVICE_UPDATE_FLAG_MIXING, EMS_TYPE_MMPLUSStatusMessage_WWC2, "MMPLUSStatusMessage_WWC2", _process_MMPLUSStatusMessageWW},
|
||||
{EMS_DEVICE_UPDATE_FLAG_MIXING, EMS_TYPE_MMStatusMessage, "MMStatusMessage", _process_MMStatusMessage}
|
||||
};
|
||||
|
||||
|
||||
18
src/ems.h
18
src/ems.h
@@ -34,6 +34,7 @@
|
||||
|
||||
// thermostat specific
|
||||
#define EMS_THERMOSTAT_MAXHC 4 // max number of heating circuits
|
||||
#define EMS_THERMOSTAT_MAXWWC 2 // max number of warm water circuits
|
||||
#define EMS_THERMOSTAT_DEFAULTHC 1 // default heating circuit is 1
|
||||
#define EMS_THERMOSTAT_WRITE_YES true
|
||||
#define EMS_THERMOSTAT_WRITE_NO false
|
||||
@@ -112,9 +113,10 @@ typedef enum {
|
||||
EMS_SYS_LOGGING_WATCH, // watch a specific type ID
|
||||
EMS_SYS_LOGGING_BASIC, // only basic read/write messages
|
||||
EMS_SYS_LOGGING_THERMOSTAT, // only telegrams sent from thermostat
|
||||
EMS_SYS_LOGGING_SOLARMODULE, // only telegrams sent from thermostat
|
||||
EMS_SYS_LOGGING_SOLARMODULE, // only telegrams sent from solarmodule
|
||||
EMS_SYS_LOGGING_VERBOSE, // everything
|
||||
EMS_SYS_LOGGING_JABBER // lots of debug output...
|
||||
EMS_SYS_LOGGING_JABBER, // lots of debug output...
|
||||
EMS_SYS_LOGGING_DEVICE // watch the device ID
|
||||
} _EMS_SYS_LOGGING;
|
||||
|
||||
// status/counters since last power on
|
||||
@@ -126,7 +128,7 @@ typedef struct {
|
||||
uint16_t emxCrcErr; // CRC errors
|
||||
bool emsPollEnabled; // flag enable the response to poll messages
|
||||
_EMS_SYS_LOGGING emsLogging; // logging
|
||||
uint16_t emsLogging_typeID; // the typeID to watch
|
||||
uint16_t emsLogging_ID; // the type or device ID to watch
|
||||
uint8_t emsRefreshedFlags; // fresh data, needs to be pushed out to MQTT
|
||||
bool emsBusConnected; // is there an active bus
|
||||
uint32_t emsRxTimestamp; // timestamp of last EMS message received
|
||||
@@ -344,6 +346,15 @@ typedef struct {
|
||||
uint8_t flowSetTemp;
|
||||
} _EMS_Mixing_HC;
|
||||
|
||||
// Mixing Module per WWC
|
||||
typedef struct {
|
||||
uint8_t wwc; // warm water circuit 1, 2
|
||||
bool active; // true if there is data for this WWC
|
||||
uint16_t flowTemp;
|
||||
uint8_t pumpMod;
|
||||
uint8_t tempStatus;
|
||||
} _EMS_Mixing_WWC;
|
||||
|
||||
// Mixer data
|
||||
typedef struct {
|
||||
uint8_t device_id;
|
||||
@@ -353,6 +364,7 @@ typedef struct {
|
||||
char version[10];
|
||||
bool detected;
|
||||
_EMS_Mixing_HC hc[EMS_THERMOSTAT_MAXHC]; // array for the 4 heating circuits
|
||||
_EMS_Mixing_WWC wwc[EMS_THERMOSTAT_MAXWWC]; // array for the 2 ww circuits
|
||||
} _EMS_Mixing;
|
||||
|
||||
// Solar Module - SM10/SM100/SM200/ISM1
|
||||
|
||||
@@ -46,7 +46,7 @@
|
||||
#define EMS_OFFSET_UBAParameterWW_wwtemp 2 // WW Temperature
|
||||
#define EMS_OFFSET_UBAParameterWW_wwactivated 1 // WW Activated
|
||||
#define EMS_OFFSET_UBAParameterWW_wwOneTime 0x00 // WW OneTime loading
|
||||
#define EMS_OFFSET_UBAParameterWW_wwCirulation 1 // WW circulation
|
||||
#define EMS_OFFSET_UBAParameterWW_wwCirulation 1 // WW circulation
|
||||
#define EMS_OFFSET_UBAParameterWW_wwComfort 9 // WW is in comfort or eco mode
|
||||
#define EMS_VALUE_UBAParameterWW_wwComfort_Hot 0x00 // the value for hot
|
||||
#define EMS_VALUE_UBAParameterWW_wwComfort_Eco 0xD8 // the value for eco
|
||||
@@ -176,9 +176,14 @@
|
||||
#define EMS_TYPE_MMPLUSStatusMessage_HC2 0x01D8 // mixer status HC2
|
||||
#define EMS_TYPE_MMPLUSStatusMessage_HC3 0x01D9 // mixer status HC3
|
||||
#define EMS_TYPE_MMPLUSStatusMessage_HC4 0x01DA // mixer status HC4
|
||||
#define EMS_TYPE_MMPLUSStatusMessage_WWC1 0x0231 // mixer status WWC1
|
||||
#define EMS_TYPE_MMPLUSStatusMessage_WWC2 0x0232 // mixer status WWC2
|
||||
#define EMS_OFFSET_MMPLUSStatusMessage_flow_temp 3 // flow temperature
|
||||
#define EMS_OFFSET_MMPLUSStatusMessage_pump_mod 5 // pump modulation
|
||||
#define EMS_OFFSET_MMPLUSStatusMessage_valve_status 2 // valve in percent
|
||||
#define EMS_OFFSET_MMPLUSStatusMessage_WW_flow_temp 0 // flow temperature
|
||||
#define EMS_OFFSET_MMPLUSStatusMessage_WW_pump_mod 2 // pump on 6, off 0
|
||||
#define EMS_OFFSET_MMPLUSStatusMessage_WW_temp_status 11 // 0,1,2
|
||||
|
||||
// MM10
|
||||
#define EMS_TYPE_MMStatusMessage 0xAB // mixer status
|
||||
|
||||
@@ -1 +1 @@
|
||||
#define APP_VERSION "1.9.5b17"
|
||||
#define APP_VERSION "1.9.5b17m"
|
||||
|
||||
Reference in New Issue