| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 85 | 2 | 1/100 |
| dhw.nrg | energy | uint24 (>=0<=10000000) | kWh | true | DHW | 0 | 2 | 1/100 |
### CS5800i, CS6800i, WLW176i, WLW186i
### CS5800iG
| shortname | fullname | type | uom | writeable | tag type | register offset | register count | scale factor |
|-|-|-|-|-|-|-|-|-|
| reset | reset | cmd [-\|maintenance\|error\|history\|message] | | true | DEVICE_DATA | 0 | 1 | 1 |
| heatingoff | force heating off | boolean | | true | DEVICE_DATA | 1 | 1 | 1 |
| heatingactive | heating active | boolean | | false | DEVICE_DATA | 2 | 1 | 1 |
| tapwateractive | tapwater active | boolean | | false | DEVICE_DATA | 3 | 1 | 1 |
| selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | true | DEVICE_DATA | 4 | 1 | 1 |
| heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | false | DEVICE_DATA | 5 | 1 | 1 |
| outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | false | DEVICE_DATA | 6 | 1 | 1/10 |
| curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | false | DEVICE_DATA | 7 | 1 | 1/10 |
| rettemp | return temperature | uint16 (>=0<=3199) | C | false | DEVICE_DATA | 8 | 1 | 1/10 |
| switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | false | DEVICE_DATA | 9 | 1 | 1/10 |
| syspress | system pressure | uint8 (>=0<=25) | bar | false | DEVICE_DATA | 10 | 1 | 1/10 |
| boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | false | DEVICE_DATA | 11 | 1 | 1/10 |
| headertemp | low loss header | uint16 (>=0<=3199) | C | false | DEVICE_DATA | 12 | 1 | 1/10 |
| exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | false | DEVICE_DATA | 244 | 1 | 1/10 |
| burngas | gas | boolean | | false | DEVICE_DATA | 245 | 1 | 1 |
| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 246 | 1 | 1 |
| flamecurr | flame current | uint16 (>=0<=3199) | µA | false | DEVICE_DATA | 247 | 1 | 1/10 |
| fanwork | fan | boolean | | false | DEVICE_DATA | 248 | 1 | 1 |
| ignwork | ignition | boolean | | false | DEVICE_DATA | 249 | 1 | 1 |
| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 250 | 1 | 1 |
| burnminpower | burner min power | uint8 (>=0<=100) | % | true | DEVICE_DATA | 251 | 1 | 1 |
| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 252 | 1 | 1 |
| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 253 | 1 | 1 |
| absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | false | DEVICE_DATA | 254 | 1 | 1 |
| heatblock | heating block | uint16 (>=0<=3199) | C | false | DEVICE_DATA | 255 | 1 | 1/10 |
| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 256 | 1 | 1 |
| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 257 | 1 | 1 |
| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 258 | 1 | 1 |
| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 259 | 1 | 1 |
| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 260 | 1 | 1 |
| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 261 | 1 | 1 |
| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 262 | 1 | 1 |
| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 263 | 1 | 1 |
| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 264 | 1 | 1 |
| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 265 | 1 | 1 |
| heatingactivated | heating activated | boolean | | true | DEVICE_DATA | 13 | 1 | 1 |
| heatingtemp | heating temperature | uint8 (>=0<=90) | C | true | DEVICE_DATA | 14 | 1 | 1 |
| heatingpump | heating pump | boolean | | false | DEVICE_DATA | 15 | 1 | 1 |
| pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | true | DEVICE_DATA | 16 | 1 | 1 |
| pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | true | DEVICE_DATA | 17 | 1 | 1 |
| pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | | true | DEVICE_DATA | 18 | 1 | 1 |
| pumpcharacter | boiler pump characteristic | enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar] | | true | DEVICE_DATA | 19 | 1 | 1 |
| pumpdelay | pump delay | uint8 (>=0<=60) | minutes | true | DEVICE_DATA | 20 | 1 | 1 |
| pumpontemp | pump logic temperature | uint8 (>=0<=60) | C | true | DEVICE_DATA | 21 | 1 | 1 |
| selburnpow | burner selected max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 22 | 1 | 1 |
| curburnpow | burner current power | uint8 (>=0<=100) | % | false | DEVICE_DATA | 23 | 1 | 1 |
| burnstarts | burner starts | uint24 (>=0<=16777214) | | false | DEVICE_DATA | 24 | 2 | 1 |
| burnworkmin | total burner operating time | time (>=0<=16777214) | minutes | false | DEVICE_DATA | 26 | 2 | 1 |
| burn2workmin | burner stage 2 operating time | time (>=0<=16777214) | minutes | false | DEVICE_DATA | 28 | 2 | 1 |
| heatworkmin | total heat operating time | time (>=0<=16777214) | minutes | false | DEVICE_DATA | 30 | 2 | 1 |
| heatstarts | burner starts heating | uint24 (>=0<=16777214) | | false | DEVICE_DATA | 32 | 2 | 1 |
| ubauptime | total UBA operating time | time (>=0<=16777214) | minutes | false | DEVICE_DATA | 34 | 2 | 1 |
| lastcode | last error code | string | | false | DEVICE_DATA | 36 | 28 | 1 |
| servicecode | service code | string | | false | DEVICE_DATA | 64 | 2 | 1 |
| servicecodenumber | service code number | uint16 (>=0<=31999) | | false | DEVICE_DATA | 66 | 1 | 1 |
| maintenancemessage | maintenance message | string | | false | DEVICE_DATA | 67 | 2 | 1 |
| maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | | true | DEVICE_DATA | 69 | 1 | 1 |
| maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | true | DEVICE_DATA | 70 | 1 | 1 |
| maintenancedate | next maintenance date | string | | true | DEVICE_DATA | 71 | 6 | 1 |
| emergencyops | emergency operation | boolean | | true | DEVICE_DATA | 77 | 1 | 1 |
| emergencytemp | emergency temperature | uint8 (>=15<=70) | C | true | DEVICE_DATA | 78 | 1 | 1 |
| pc0flow | Flow PC0 | int16 (>=-31999<=31999) | l/h | false | DEVICE_DATA | 79 | 1 | 1 |
| pc1flow | Flow PC1 | int16 (>=-31999<=31999) | l/h | false | DEVICE_DATA | 80 | 1 | 1 |
| pc1on | PC1 | boolean | | false | DEVICE_DATA | 81 | 1 | 1 |
| pc1rate | PC1 rate | uint8 (>=0<=100) | % | false | DEVICE_DATA | 82 | 1 | 1 |
| meterheat | meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 95 | 2 | 1/10 |
| dhw.meter | meter | uint24 (>=0<=1677721) | kWh | false | DHW | 2 | 2 | 1/10 |
| gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 266 | 2 | 1/10 |
| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 70 | 2 | 1/10 |
| nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 268 | 2 | 1/10 |
| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 72 | 2 | 1/10 |
| dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 |
| dhw.settemp | set temperature | uint8 (>=0<=254) | C | false | DHW | 29 | 1 | 1 |
| dhw.seltemp | selected temperature | uint8 (>=0<=254) | C | true | DHW | 30 | 1 | 1 |
| dhw.seltemplow | selected lower temperature | uint8 (>=0<=254) | C | true | DHW | 31 | 1 | 1 |
| dhw.tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | true | DHW | 32 | 1 | 1 |
| dhw.seltempoff | selected temperature for off | uint8 (>=0<=254) | C | false | DHW | 33 | 1 | 1 |
| dhw.seltempsingle | single charge temperature | uint8 (>=0<=254) | C | true | DHW | 34 | 1 | 1 |
| dhw.solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | false | DHW | 35 | 1 | 1/10 |
| dhw.type | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | | false | DHW | 36 | 1 | 1 |
| dhw.comfort | comfort | enum [hot\|eco\|intelligent] | | true | DHW | 37 | 1 | 1 |
| dhw.comfort1 | comfort mode | enum [high comfort\|eco] | | true | DHW | 38 | 1 | 1 |
| dhw.flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | true | DHW | 39 | 1 | 1 |
| dhw.chargeoptimization | charge optimization | boolean | | true | DHW | 40 | 1 | 1 |
| dhw.maxpower | max power | uint8 (>=0<=254) | % | true | DHW | 41 | 1 | 1 |
| dhw.maxtemp | maximum temperature | uint8 (>=0<=80) | C | true | DHW | 42 | 1 | 1 |
| dhw.circpump | circulation pump available | boolean | | true | DHW | 43 | 1 | 1 |
| dhw.chargetype | charging type | enum [chargepump\|3-way valve] | | false | DHW | 44 | 1 | 1 |
| dhw.hyston | hysteresis on temperature | int8 (>=-126<=126) | C | true | DHW | 45 | 1 | 1 |
| dhw.hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | true | DHW | 46 | 1 | 1 |
| dhw.disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | true | DHW | 47 | 1 | 1 |
| dhw.circmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | | true | DHW | 48 | 1 | 1 |
| dhw.circ | circulation active | boolean | | true | DHW | 49 | 1 | 1 |
| dhw.curtemp | current intern temperature | uint16 (>=0<=3199) | C | false | DHW | 50 | 1 | 1/10 |
| dhw.curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | false | DHW | 51 | 1 | 1/10 |
| dhw.curflow | current tap water flow | uint8 (>=0<=25) | l/min | false | DHW | 52 | 1 | 1/10 |
| dhw.storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | false | DHW | 53 | 1 | 1/10 |
| dhw.storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | false | DHW | 54 | 1 | 1/10 |
| dhw.activated | activated | boolean | | true | DHW | 55 | 1 | 1 |
| dhw.onetime | one time charging | boolean | | true | DHW | 56 | 1 | 1 |
| dhw.disinfecting | disinfecting | boolean | | true | DHW | 57 | 1 | 1 |
| dhw.charging | charging | boolean | | false | DHW | 58 | 1 | 1 |
| dhw.recharging | recharging | boolean | | false | DHW | 59 | 1 | 1 |
| dhw.tempok | temperature ok | boolean | | false | DHW | 60 | 1 | 1 |
| dhw.active | active | boolean | | false | DHW | 61 | 1 | 1 |
| dhw.3wayvalve | 3-way valve active | boolean | | false | DHW | 62 | 1 | 1 |
| dhw.chargepump | charge pump | boolean | | false | DHW | 63 | 1 | 1 |
| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 |
| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 65 | 1 | 1/10 |
| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 66 | 2 | 1 |
| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 68 | 2 | 1 |
| nompower | nominal Power | uint8 (>=0<=254) | kW | true | DEVICE_DATA | 270 | 1 | 1 |
| nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 83 | 2 | 1/100 |
| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 85 | 2 | 1/100 |
| dhw.nrg | energy | uint24 (>=0<=10000000) | kWh | true | DHW | 0 | 2 | 1/100 |
### CS5800iXXX, CS6800i, WLW176i, WLW186i
| shortname | fullname | type | uom | writeable | tag type | register offset | register count | scale factor |
|-|-|-|-|-|-|-|-|-|
| reset | reset | cmd [-\|maintenance\|error\|history\|message] | | true | DEVICE_DATA | 0 | 1 | 1 |
@@ -469,125 +588,6 @@
| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 66 | 2 | 1 |
| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 68 | 2 | 1 |
### CS5800iG
| shortname | fullname | type | uom | writeable | tag type | register offset | register count | scale factor |
|-|-|-|-|-|-|-|-|-|
| reset | reset | cmd [-\|maintenance\|error\|history\|message] | | true | DEVICE_DATA | 0 | 1 | 1 |
| heatingoff | force heating off | boolean | | true | DEVICE_DATA | 1 | 1 | 1 |
| heatingactive | heating active | boolean | | false | DEVICE_DATA | 2 | 1 | 1 |
| tapwateractive | tapwater active | boolean | | false | DEVICE_DATA | 3 | 1 | 1 |
| selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | true | DEVICE_DATA | 4 | 1 | 1 |
| heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | false | DEVICE_DATA | 5 | 1 | 1 |
| outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | false | DEVICE_DATA | 6 | 1 | 1/10 |
| curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | false | DEVICE_DATA | 7 | 1 | 1/10 |
| rettemp | return temperature | uint16 (>=0<=3199) | C | false | DEVICE_DATA | 8 | 1 | 1/10 |
| switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | false | DEVICE_DATA | 9 | 1 | 1/10 |
| syspress | system pressure | uint8 (>=0<=25) | bar | false | DEVICE_DATA | 10 | 1 | 1/10 |
| boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | false | DEVICE_DATA | 11 | 1 | 1/10 |
| headertemp | low loss header | uint16 (>=0<=3199) | C | false | DEVICE_DATA | 12 | 1 | 1/10 |
| exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | false | DEVICE_DATA | 244 | 1 | 1/10 |
| burngas | gas | boolean | | false | DEVICE_DATA | 245 | 1 | 1 |
| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 246 | 1 | 1 |
| flamecurr | flame current | uint16 (>=0<=3199) | µA | false | DEVICE_DATA | 247 | 1 | 1/10 |
| fanwork | fan | boolean | | false | DEVICE_DATA | 248 | 1 | 1 |
| ignwork | ignition | boolean | | false | DEVICE_DATA | 249 | 1 | 1 |
| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 250 | 1 | 1 |
| burnminpower | burner min power | uint8 (>=0<=100) | % | true | DEVICE_DATA | 251 | 1 | 1 |
| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 252 | 1 | 1 |
| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 253 | 1 | 1 |
| absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | false | DEVICE_DATA | 254 | 1 | 1 |
| heatblock | heating block | uint16 (>=0<=3199) | C | false | DEVICE_DATA | 255 | 1 | 1/10 |
| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 256 | 1 | 1 |
| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 257 | 1 | 1 |
| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 258 | 1 | 1 |
| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 259 | 1 | 1 |
| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 260 | 1 | 1 |
| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 261 | 1 | 1 |
| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 262 | 1 | 1 |
| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 263 | 1 | 1 |
| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 264 | 1 | 1 |
| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 265 | 1 | 1 |
| heatingactivated | heating activated | boolean | | true | DEVICE_DATA | 13 | 1 | 1 |
| heatingtemp | heating temperature | uint8 (>=0<=90) | C | true | DEVICE_DATA | 14 | 1 | 1 |
| heatingpump | heating pump | boolean | | false | DEVICE_DATA | 15 | 1 | 1 |
| pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | true | DEVICE_DATA | 16 | 1 | 1 |
| pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | true | DEVICE_DATA | 17 | 1 | 1 |
| pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | | true | DEVICE_DATA | 18 | 1 | 1 |
| pumpcharacter | boiler pump characteristic | enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar] | | true | DEVICE_DATA | 19 | 1 | 1 |
| pumpdelay | pump delay | uint8 (>=0<=60) | minutes | true | DEVICE_DATA | 20 | 1 | 1 |
| pumpontemp | pump logic temperature | uint8 (>=0<=60) | C | true | DEVICE_DATA | 21 | 1 | 1 |
| selburnpow | burner selected max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 22 | 1 | 1 |
| curburnpow | burner current power | uint8 (>=0<=100) | % | false | DEVICE_DATA | 23 | 1 | 1 |
| burnstarts | burner starts | uint24 (>=0<=16777214) | | false | DEVICE_DATA | 24 | 2 | 1 |
| burnworkmin | total burner operating time | time (>=0<=16777214) | minutes | false | DEVICE_DATA | 26 | 2 | 1 |
| burn2workmin | burner stage 2 operating time | time (>=0<=16777214) | minutes | false | DEVICE_DATA | 28 | 2 | 1 |
| heatworkmin | total heat operating time | time (>=0<=16777214) | minutes | false | DEVICE_DATA | 30 | 2 | 1 |
| heatstarts | burner starts heating | uint24 (>=0<=16777214) | | false | DEVICE_DATA | 32 | 2 | 1 |
| ubauptime | total UBA operating time | time (>=0<=16777214) | minutes | false | DEVICE_DATA | 34 | 2 | 1 |
| lastcode | last error code | string | | false | DEVICE_DATA | 36 | 28 | 1 |
| servicecode | service code | string | | false | DEVICE_DATA | 64 | 2 | 1 |
| servicecodenumber | service code number | uint16 (>=0<=31999) | | false | DEVICE_DATA | 66 | 1 | 1 |
| maintenancemessage | maintenance message | string | | false | DEVICE_DATA | 67 | 2 | 1 |
| maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | | true | DEVICE_DATA | 69 | 1 | 1 |
| maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | true | DEVICE_DATA | 70 | 1 | 1 |
| maintenancedate | next maintenance date | string | | true | DEVICE_DATA | 71 | 6 | 1 |
| emergencyops | emergency operation | boolean | | true | DEVICE_DATA | 77 | 1 | 1 |
| emergencytemp | emergency temperature | uint8 (>=15<=70) | C | true | DEVICE_DATA | 78 | 1 | 1 |
| pc0flow | Flow PC0 | int16 (>=-31999<=31999) | l/h | false | DEVICE_DATA | 79 | 1 | 1 |
| pc1flow | Flow PC1 | int16 (>=-31999<=31999) | l/h | false | DEVICE_DATA | 80 | 1 | 1 |
| pc1on | PC1 | boolean | | false | DEVICE_DATA | 81 | 1 | 1 |
| pc1rate | PC1 rate | uint8 (>=0<=100) | % | false | DEVICE_DATA | 82 | 1 | 1 |
| meterheat | meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 95 | 2 | 1/10 |
| dhw.meter | meter | uint24 (>=0<=1677721) | kWh | false | DHW | 2 | 2 | 1/10 |
| gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 266 | 2 | 1/10 |
| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 70 | 2 | 1/10 |
| nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 268 | 2 | 1/10 |
| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 72 | 2 | 1/10 |
| dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 |
| dhw.settemp | set temperature | uint8 (>=0<=254) | C | false | DHW | 29 | 1 | 1 |
| dhw.seltemp | selected temperature | uint8 (>=0<=254) | C | true | DHW | 30 | 1 | 1 |
| dhw.seltemplow | selected lower temperature | uint8 (>=0<=254) | C | true | DHW | 31 | 1 | 1 |
| dhw.tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | true | DHW | 32 | 1 | 1 |
| dhw.seltempoff | selected temperature for off | uint8 (>=0<=254) | C | false | DHW | 33 | 1 | 1 |
| dhw.seltempsingle | single charge temperature | uint8 (>=0<=254) | C | true | DHW | 34 | 1 | 1 |
| dhw.solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | false | DHW | 35 | 1 | 1/10 |
| dhw.type | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | | false | DHW | 36 | 1 | 1 |
| dhw.comfort | comfort | enum [hot\|eco\|intelligent] | | true | DHW | 37 | 1 | 1 |
| dhw.comfort1 | comfort mode | enum [high comfort\|eco] | | true | DHW | 38 | 1 | 1 |
| dhw.flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | true | DHW | 39 | 1 | 1 |
| dhw.chargeoptimization | charge optimization | boolean | | true | DHW | 40 | 1 | 1 |
| dhw.maxpower | max power | uint8 (>=0<=254) | % | true | DHW | 41 | 1 | 1 |
| dhw.maxtemp | maximum temperature | uint8 (>=0<=80) | C | true | DHW | 42 | 1 | 1 |
| dhw.circpump | circulation pump available | boolean | | true | DHW | 43 | 1 | 1 |
| dhw.chargetype | charging type | enum [chargepump\|3-way valve] | | false | DHW | 44 | 1 | 1 |
| dhw.hyston | hysteresis on temperature | int8 (>=-126<=126) | C | true | DHW | 45 | 1 | 1 |
| dhw.hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | true | DHW | 46 | 1 | 1 |
| dhw.disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | true | DHW | 47 | 1 | 1 |
| dhw.circmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | | true | DHW | 48 | 1 | 1 |
| dhw.circ | circulation active | boolean | | true | DHW | 49 | 1 | 1 |
| dhw.curtemp | current intern temperature | uint16 (>=0<=3199) | C | false | DHW | 50 | 1 | 1/10 |
| dhw.curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | false | DHW | 51 | 1 | 1/10 |
| dhw.curflow | current tap water flow | uint8 (>=0<=25) | l/min | false | DHW | 52 | 1 | 1/10 |
| dhw.storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | false | DHW | 53 | 1 | 1/10 |
| dhw.storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | false | DHW | 54 | 1 | 1/10 |
| dhw.activated | activated | boolean | | true | DHW | 55 | 1 | 1 |
| dhw.onetime | one time charging | boolean | | true | DHW | 56 | 1 | 1 |
| dhw.disinfecting | disinfecting | boolean | | true | DHW | 57 | 1 | 1 |
| dhw.charging | charging | boolean | | false | DHW | 58 | 1 | 1 |
| dhw.recharging | recharging | boolean | | false | DHW | 59 | 1 | 1 |
| dhw.tempok | temperature ok | boolean | | false | DHW | 60 | 1 | 1 |
| dhw.active | active | boolean | | false | DHW | 61 | 1 | 1 |
| dhw.3wayvalve | 3-way valve active | boolean | | false | DHW | 62 | 1 | 1 |
| dhw.chargepump | charge pump | boolean | | false | DHW | 63 | 1 | 1 |
| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 |
| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 65 | 1 | 1/10 |
| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 66 | 2 | 1 |
| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 68 | 2 | 1 |
| nompower | nominal Power | uint8 (>=0<=254) | kW | true | DEVICE_DATA | 270 | 1 | 1 |
| nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 83 | 2 | 1/100 |
| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 85 | 2 | 1/100 |
| dhw.nrg | energy | uint24 (>=0<=10000000) | kWh | true | DHW | 0 | 2 | 1/100 |
### Cascade CM10
| shortname | fullname | type | uom | writeable | tag type | register offset | register count | scale factor |
|-|-|-|-|-|-|-|-|-|

View File

@@ -1,212 +1,212 @@
device name,device type,product id,shortname,fullname,type [options...] \| (min/max),uom,writeable,discovery entityid v3.4,discovery entityid,modbus unit identifier,modbus block,modbus scale factor,modbus offset,modbus count
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,21,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,22,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,23,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,burnstarts,burner starts,uint24 (>=0<=16777214), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,24,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,burnworkmin,total burner operating time,time (>=0<=16777214),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,26,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,burn2workmin,burner stage 2 operating time,time (>=0<=16777214),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,28,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,heatworkmin,total heat operating time,time (>=0<=16777214),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,30,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,heatstarts,burner starts heating,uint24 (>=0<=16777214), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,32,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,ubauptime,total UBA operating time,time (>=0<=16777214),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,34,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,36,28
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,64,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,66,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,67,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,69,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,70,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,71,6
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,77,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,78,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pc0flow,Flow PC0,int16 (>=-31999<=31999),l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,5,0,1,79,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pc1flow,Flow PC1,int16 (>=-31999<=31999),l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,5,0,1,80,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,5,0,1,81,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pc1rate,PC1 rate,uint8 (>=0<=100),%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,5,0,1,82,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,83,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.nrg,energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_energy,sensor.boiler_dhw_nrg,5,9,1/100,0,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_energy_heating,sensor.boiler_nrgheat,5,0,1/100,85,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgcool,energy cooling,uint24 (>=0<=167772),kWh,false,sensor.boiler_energy_cooling,sensor.boiler_nrgcool,5,0,1/100,87,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_total,sensor.boiler_metertotal,5,0,1/100,89,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_compressor,sensor.boiler_metercomp,5,0,1/100,91,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_e-heater,sensor.boiler_metereheat,5,0,1/100,93,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/100,95,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,metercool,meter cooling,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_cooling,sensor.boiler_metercool,5,0,1/100,97,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.meter,meter,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/100,2,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,uptimetotal,heatpump total uptime,time (>=0<=279620),minutes,false,sensor.boiler_heatpump_total_uptime,sensor.boiler_uptimetotal,5,0,1/60,99,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,uptimecontrol,total operating time heat,time (>=0<=279620),minutes,false,sensor.boiler_total_operating_time_heat,sensor.boiler_uptimecontrol,5,0,1/60,101,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,uptimecompheating,operating time compressor heating,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_heating,sensor.boiler_uptimecompheating,5,0,1/60,103,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,uptimecompcooling,operating time compressor cooling,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_cooling,sensor.boiler_uptimecompcooling,5,0,1/60,105,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.uptimecomp,operating time compressor,time (>=0<=279620),minutes,false,sensor.boiler_dhw_operating_time_compressor,sensor.boiler_dhw_uptimecomp,5,9,1/60,4,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,uptimecomppool,operating time compressor pool,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_pool,sensor.boiler_uptimecomppool,5,0,1/60,107,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,totalcompstarts,total compressor control starts,uint24 (>=0<=16777214), ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts,5,0,1,109,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,heatingstarts,heating control starts,uint24 (>=0<=16777214), ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts,5,0,1,111,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,coolingstarts,cooling control starts,uint24 (>=0<=16777214), ,false,sensor.boiler_cooling_control_starts,sensor.boiler_coolingstarts,5,0,1,113,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.startshp,starts hp,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts_hp,sensor.boiler_dhw_startshp,5,9,1,6,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,poolstarts,pool control starts,uint24 (>=0<=16777214), ,false,sensor.boiler_pool_control_starts,sensor.boiler_poolstarts,5,0,1,115,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgconstotal,total energy consumption,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal,5,0,1,117,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgconscomptotal,total energy consumption compressor,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal,5,0,1,119,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgconscompheating,energy consumption compressor heating,uint24 (>=0<=16777214),kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating,5,0,1,121,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.nrgconscomp,energy consumption compressor,uint24 (>=0<=16777214),kWh,false,sensor.boiler_dhw_energy_consumption_compressor,sensor.boiler_dhw_nrgconscomp,5,9,1,8,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgconscompcooling,energy consumption compressor cooling,uint24 (>=0<=16777214),kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling,5,0,1,123,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgconscomppool,energy consumption compressor pool,uint24 (>=0<=16777214),kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool,5,0,1,125,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxelecheatnrgconstotal,total aux elec. heater energy consumption,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal,5,0,1,127,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,uint24 (>=0<=16777214),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating,5,0,1,129,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.auxelecheatnrgcons,aux elec. heater energy consumption,uint24 (>=0<=16777214),kWh,false,sensor.boiler_dhw_aux_elec._heater_energy_consumption,sensor.boiler_dhw_auxelecheatnrgcons,5,9,1,10,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxelecheatnrgconspool,aux elec. heater energy consumption pool,uint24 (>=0<=16777214),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool,5,0,1,131,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgsupptotal,total energy supplied,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal,5,0,1,133,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgsuppheating,total energy supplied heating,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating,5,0,1,135,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.nrgsupp,total energy warm supplied,uint24 (>=0<=16777214),kWh,false,sensor.boiler_dhw_total_energy_warm_supplied,sensor.boiler_dhw_nrgsupp,5,9,1,12,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgsuppcooling,total energy supplied cooling,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling,5,0,1,137,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgsupppool,total energy supplied pool,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool,5,0,1,139,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hppower,compressor power output,uint16 (>=0<=3199),kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower,5,0,1/10,141,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpmaxpower,compressor max power,uint8 (>=0<=100),%,true,number.boiler_compressor_max_power,number.boiler_hpmaxpower,5,0,1,142,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pvmaxcomp,pv compressor max power,uint8 (>=0<=25),kW,true,number.boiler_pv_compressor_max_power,number.boiler_pvmaxcomp,5,0,1/10,143,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,powerreduction,power reduction,uint8 (>=30<=60),%,true,number.boiler_power_reduction,number.boiler_powerreduction,5,0,10,144,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpsetdiffpress,set differential pressure,uint8 (>=150<=750),mbar,true,number.boiler_set_differential_pressure,number.boiler_hpsetdiffpress,5,0,50,145,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpcompon,hp compressor,boolean, ,false,binary_sensor.boiler_hp_compressor,binary_sensor.boiler_hpcompon,5,0,1,146,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpactivity,compressor activity,enum [off\|heating\|cooling\|hot water\|pool\|pool heating\|defrost\|compressor alarm], ,false,sensor.boiler_compressor_activity,sensor.boiler_hpactivity,5,0,1,147,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpbrinepumpspd,brine pump speed,uint8 (>=0<=100),%,false,sensor.boiler_brine_pump_speed,sensor.boiler_hpbrinepumpspd,5,0,1,148,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpswitchvalve,switch valve,boolean, ,false,binary_sensor.boiler_switch_valve,binary_sensor.boiler_hpswitchvalve,5,0,1,149,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpcompspd,compressor speed,uint8 (>=0<=100),%,false,sensor.boiler_compressor_speed,sensor.boiler_hpcompspd,5,0,1,150,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpcircspd,circulation pump speed,uint8 (>=0<=100),%,false,sensor.boiler_circulation_pump_speed,sensor.boiler_hpcircspd,5,0,1,151,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpbrinein,brine in/evaporator,int16 (>=-3199<=3199),C,false,sensor.boiler_brine_in/evaporator,sensor.boiler_hpbrinein,5,0,1/10,152,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpbrineout,brine out/condenser,int16 (>=-3199<=3199),C,false,sensor.boiler_brine_out/condenser,sensor.boiler_hpbrineout,5,0,1/10,153,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptc0,heat carrier return (TC0),int16 (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_return_(TC0),sensor.boiler_hptc0,5,0,1/10,154,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptc1,heat carrier forward (TC1),int16 (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_forward_(TC1),sensor.boiler_hptc1,5,0,1/10,155,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptc3,condenser temperature (TC3),int16 (>=-3199<=3199),C,false,sensor.boiler_condenser_temperature_(TC3),sensor.boiler_hptc3,5,0,1/10,156,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptr1,compressor temperature (TR1),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_temperature_(TR1),sensor.boiler_hptr1,5,0,1/10,157,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptr3,refrigerant temperature liquid side (condenser output) (TR3),int16 (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.boiler_hptr3,5,0,1/10,158,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptr4,evaporator inlet temperature (TR4),int16 (>=-3199<=3199),C,false,sensor.boiler_evaporator_inlet_temperature_(TR4),sensor.boiler_hptr4,5,0,1/10,159,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptr5,compressor inlet temperature (TR5),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_inlet_temperature_(TR5),sensor.boiler_hptr5,5,0,1/10,160,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptr6,compressor outlet temperature (TR6),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_outlet_temperature_(TR6),sensor.boiler_hptr6,5,0,1/10,161,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptr7,refrigerant temperature gas side (condenser input) (TR7),int16 (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7),sensor.boiler_hptr7,5,0,1/10,162,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptl2,air inlet temperature (TL2),int16 (>=-3199<=3199),C,false,sensor.boiler_air_inlet_temperature_(TL2),sensor.boiler_hptl2,5,0,1/10,163,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hppl1,low pressure side temperature (PL1),int16 (>=-3199<=3199),C,false,sensor.boiler_low_pressure_side_temperature_(PL1),sensor.boiler_hppl1,5,0,1/10,164,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpph1,high pressure side temperature (PH1),int16 (>=-3199<=3199),C,false,sensor.boiler_high_pressure_side_temperature_(PH1),sensor.boiler_hpph1,5,0,1/10,165,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpta4,drain pan temp (TA4),int16 (>=-3199<=3199),C,false,sensor.boiler_drain_pan_temp_(TA4),sensor.boiler_hpta4,5,0,1/10,166,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptw1,reservoir temp (TW1),int16 (>=-3199<=3199),C,false,sensor.boiler_reservoir_temp_(TW1),sensor.boiler_hptw1,5,0,1/10,167,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,poolsettemp,pool set temperature,uint8 (>=0<=127),C,true,number.boiler_pool_set_temperature,number.boiler_poolsettemp,5,0,1/2,168,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hp4way,4-way valve (VR4),enum [cooling & defrost\|heating & dhw], ,false,sensor.boiler_4-way_valve_(VR4),sensor.boiler_hp4way,5,0,1,169,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpin1,input 1 state,boolean, ,false,binary_sensor.boiler_input_1_state,binary_sensor.boiler_hpin1,5,0,1,170,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpin1opt,input 1 options,string, ,true,sensor.boiler_input_1_options,sensor.boiler_hpin1opt,5,0,1,171,8
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpin2,input 2 state,boolean, ,false,binary_sensor.boiler_input_2_state,binary_sensor.boiler_hpin2,5,0,1,179,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpin2opt,input 2 options,string, ,true,sensor.boiler_input_2_options,sensor.boiler_hpin2opt,5,0,1,180,8
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpin3,input 3 state,boolean, ,false,binary_sensor.boiler_input_3_state,binary_sensor.boiler_hpin3,5,0,1,188,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpin3opt,input 3 options,string, ,true,sensor.boiler_input_3_options,sensor.boiler_hpin3opt,5,0,1,189,8
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpin4,input 4 state,boolean, ,false,binary_sensor.boiler_input_4_state,binary_sensor.boiler_hpin4,5,0,1,197,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpin4opt,input 4 options,string, ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt,5,0,1,198,8
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,maxheatcomp,heat limit compressor,enum [0 kW\|3 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp,5,0,1,206,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,maxheatheat,heat limit heating,enum [3 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat,5,0,1,207,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.maxheat,heat limit,enum [3 kW\|6 kW\|9 kW], ,true,select.boiler_dhw_heat_limit,select.boiler_dhw_maxheat,5,9,1,14,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxheatersource,aux heater source,enum [not installed\|electric heater\|exclusive\|parallel\|hybrid], ,true,select.boiler_aux_heater_source,select.boiler_auxheatersource,5,0,1,208,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pvcooling,cooling only with PV,boolean, ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling,5,0,1,209,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxheateronly,aux heater only,boolean, ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly,5,0,1,210,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxheateroff,disable aux heater,boolean, ,true,switch.boiler_disable_aux_heater,switch.boiler_auxheateroff,5,0,1,211,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxheaterstatus,aux heater status,enum [off\|heating\|cooling\|hot water\|pool\|pool heating\|defrost\|compressor alarm], ,false,sensor.boiler_aux_heater_status,sensor.boiler_auxheaterstatus,5,0,1,212,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxheaterlevel,aux heater level,uint8 (>=0<=100),%,false,sensor.boiler_aux_heater_level,sensor.boiler_auxheaterlevel,5,0,1,213,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxheaterdelay,aux heater on delay,uint16 (>=10<=1000),K*min,true,number.boiler_aux_heater_on_delay,number.boiler_auxheaterdelay,5,0,10,214,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxmaxlimit,aux heater max limit,uint8 (>=0<=10),K,true,number.boiler_aux_heater_max_limit,number.boiler_auxmaxlimit,5,0,1/10,215,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxlimitstart,aux heater limit start,uint8 (>=0<=10),K,true,number.boiler_aux_heater_limit_start,number.boiler_auxlimitstart,5,0,1/10,216,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxheatrmode,aux heater mode,enum [eco\|comfort], ,true,select.boiler_aux_heater_mode,select.boiler_auxheatrmode,5,0,1,217,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hphystheat,on/off hyst heat,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_heat,number.boiler_hphystheat,5,0,5,218,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hphystcool,on/off hyst cool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_cool,number.boiler_hphystcool,5,0,5,219,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hphystpool,on/off hyst pool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_pool,number.boiler_hphystpool,5,0,5,220,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,silentmode,silent mode,enum [off\|auto\|on], ,true,select.boiler_silent_mode,select.boiler_silentmode,5,0,1,221,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,silentfrom,silent mode from,uint8 (>=0<=3810),minutes,true,number.boiler_silent_mode_from,number.boiler_silentfrom,5,0,15,222,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,silentto,silent mode to,uint8 (>=0<=3810),minutes,true,number.boiler_silent_mode_to,number.boiler_silentto,5,0,15,223,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,mintempsilent,min outside temp for silent mode,int8 (>=-126<=126),C,true,number.boiler_min_outside_temp_for_silent_mode,number.boiler_mintempsilent,5,0,1,224,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,tempparmode,outside temp parallel mode,int8 (>=-126<=126),C,true,number.boiler_outside_temp_parallel_mode,number.boiler_tempparmode,5,0,1,225,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxheatmix,aux heater mixing valve,int8 (>=-100<=100),%,false,sensor.boiler_aux_heater_mixing_valve,sensor.boiler_auxheatmix,5,0,1,226,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,tempdiffheat,temp diff TC3/TC0 heat,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_heat,number.boiler_tempdiffheat,5,0,1/10,227,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,tempdiffcool,temp diff TC3/TC0 cool,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_cool,number.boiler_tempdiffcool,5,0,1/10,228,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,vpcooling,valve/pump cooling,boolean, ,true,switch.boiler_valve/pump_cooling,switch.boiler_vpcooling,5,0,1,229,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,heatcable,heating cable,boolean, ,true,switch.boiler_heating_cable,switch.boiler_heatcable,5,0,1,230,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,vc0valve,VC0 valve,boolean, ,true,switch.boiler_VC0_valve,switch.boiler_vc0valve,5,0,1,231,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,primepump,primary heatpump,boolean, ,true,switch.boiler_primary_heatpump,switch.boiler_primepump,5,0,1,232,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,primepumpmod,primary heatpump modulation,uint8 (>=0<=100),%,true,number.boiler_primary_heatpump_modulation,number.boiler_primepumpmod,5,0,1,233,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hp3way,3-way valve,boolean, ,true,switch.boiler_3-way_valve,switch.boiler_hp3way,5,0,1,234,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,elheatstep1,el. heater step 1,boolean, ,true,switch.boiler_el._heater_step_1,switch.boiler_elheatstep1,5,0,1,235,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,elheatstep2,el. heater step 2,boolean, ,true,switch.boiler_el._heater_step_2,switch.boiler_elheatstep2,5,0,1,236,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,elheatstep3,el. heater step 3,boolean, ,true,switch.boiler_el._heater_step_3,switch.boiler_elheatstep3,5,0,1,237,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpea0,condensate reservoir heating (EA0),boolean, ,false,binary_sensor.boiler_condensate_reservoir_heating_(EA0),binary_sensor.boiler_hpea0,5,0,1,238,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hppumpmode,primary heatpump mode,enum [auto\|continuous], ,true,select.boiler_primary_heatpump_mode,select.boiler_hppumpmode,5,0,1,239,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,fan,fan,uint8 (>=20<=100),%,true,number.boiler_fan,number.boiler_fan,5,0,1,240,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,shutdown,shutdown,cmd [off\|on], ,true,sensor.boiler_shutdown,sensor.boiler_shutdown,5,0,1,241,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpcurrpower,compressor current power,uint16 (>=0<=31999),W,false,sensor.boiler_compressor_current_power,sensor.boiler_hpcurrpower,5,0,1,242,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hppowerlimit,power limit,uint16 (>=0<=31999),W,true,number.boiler_power_limit,number.boiler_hppowerlimit,5,0,1,243,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.alternatingop,alternating operation,boolean, ,true,switch.boiler_dhw_alternating_operation,switch.boiler_dhw_alternatingop,5,9,1,15,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.altopprioheat,prioritise heating during dhw,uint8 (>=20<=120),minutes,true,number.boiler_dhw_prioritise_heating_during_dhw,number.boiler_dhw_altopprioheat,5,9,1,16,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.altopprio,prioritise dhw during heating,uint8 (>=30<=120),minutes,true,number.boiler_dhw_prioritise_dhw_during_heating,number.boiler_dhw_altopprio,5,9,1,17,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.comfoff,comfort switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_comfort_switch_off,number.boiler_dhw_comfoff,5,9,1,18,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.ecooff,eco switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_eco_switch_off,number.boiler_dhw_ecooff,5,9,1,19,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.ecoplusoff,eco+ switch off,uint8 (>=48<=63),C,true,number.boiler_dhw_eco+_switch_off,number.boiler_dhw_ecoplusoff,5,9,1,20,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.comfdiff,comfort diff,uint8 (>=4<=12),K,true,number.boiler_dhw_comfort_diff,number.boiler_dhw_comfdiff,5,9,1,21,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.ecodiff,eco diff,uint8 (>=4<=12),K,true,number.boiler_dhw_eco_diff,number.boiler_dhw_ecodiff,5,9,1,22,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.ecoplusdiff,eco+ diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco+_diff,number.boiler_dhw_ecoplusdiff,5,9,1,23,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.comfstop,comfort stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_comfort_stop_temp,number.boiler_dhw_comfstop,5,9,1,24,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.ecostop,eco stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco_stop_temp,number.boiler_dhw_ecostop,5,9,1,25,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.ecoplusstop,eco+ stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco+_stop_temp,number.boiler_dhw_ecoplusstop,5,9,1,26,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.hpcircpump,circulation pump available during dhw,boolean, ,true,switch.boiler_dhw_circulation_pump_available_during_dhw,switch.boiler_dhw_hpcircpump,5,9,1,27,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.chargepump,charge pump,boolean, ,false,binary_sensor.boiler_dhw_charge_pump,binary_sensor.boiler_dhw_chargepump,5,9,1,63,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,21,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,22,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,23,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,burnstarts,burner starts,uint24 (>=0<=16777214), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,24,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,burnworkmin,total burner operating time,time (>=0<=16777214),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,26,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,burn2workmin,burner stage 2 operating time,time (>=0<=16777214),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,28,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,heatworkmin,total heat operating time,time (>=0<=16777214),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,30,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,heatstarts,burner starts heating,uint24 (>=0<=16777214), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,32,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,ubauptime,total UBA operating time,time (>=0<=16777214),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,34,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,36,28
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,64,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,66,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,67,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,69,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,70,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,71,6
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,77,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,78,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,pc0flow,Flow PC0,int16 (>=-31999<=31999),l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,5,0,1,79,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,pc1flow,Flow PC1,int16 (>=-31999<=31999),l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,5,0,1,80,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,5,0,1,81,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,pc1rate,PC1 rate,uint8 (>=0<=100),%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,5,0,1,82,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,83,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.nrg,energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_energy,sensor.boiler_dhw_nrg,5,9,1/100,0,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_energy_heating,sensor.boiler_nrgheat,5,0,1/100,85,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,nrgcool,energy cooling,uint24 (>=0<=167772),kWh,false,sensor.boiler_energy_cooling,sensor.boiler_nrgcool,5,0,1/100,87,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_total,sensor.boiler_metertotal,5,0,1/100,89,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_compressor,sensor.boiler_metercomp,5,0,1/100,91,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_e-heater,sensor.boiler_metereheat,5,0,1/100,93,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/100,95,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,metercool,meter cooling,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_cooling,sensor.boiler_metercool,5,0,1/100,97,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.meter,meter,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/100,2,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,uptimetotal,heatpump total uptime,time (>=0<=279620),minutes,false,sensor.boiler_heatpump_total_uptime,sensor.boiler_uptimetotal,5,0,1/60,99,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,uptimecontrol,total operating time heat,time (>=0<=279620),minutes,false,sensor.boiler_total_operating_time_heat,sensor.boiler_uptimecontrol,5,0,1/60,101,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,uptimecompheating,operating time compressor heating,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_heating,sensor.boiler_uptimecompheating,5,0,1/60,103,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,uptimecompcooling,operating time compressor cooling,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_cooling,sensor.boiler_uptimecompcooling,5,0,1/60,105,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.uptimecomp,operating time compressor,time (>=0<=279620),minutes,false,sensor.boiler_dhw_operating_time_compressor,sensor.boiler_dhw_uptimecomp,5,9,1/60,4,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,uptimecomppool,operating time compressor pool,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_pool,sensor.boiler_uptimecomppool,5,0,1/60,107,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,totalcompstarts,total compressor control starts,uint24 (>=0<=16777214), ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts,5,0,1,109,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,heatingstarts,heating control starts,uint24 (>=0<=16777214), ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts,5,0,1,111,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,coolingstarts,cooling control starts,uint24 (>=0<=16777214), ,false,sensor.boiler_cooling_control_starts,sensor.boiler_coolingstarts,5,0,1,113,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.startshp,starts hp,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts_hp,sensor.boiler_dhw_startshp,5,9,1,6,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,poolstarts,pool control starts,uint24 (>=0<=16777214), ,false,sensor.boiler_pool_control_starts,sensor.boiler_poolstarts,5,0,1,115,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,nrgconstotal,total energy consumption,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal,5,0,1,117,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,nrgconscomptotal,total energy consumption compressor,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal,5,0,1,119,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,nrgconscompheating,energy consumption compressor heating,uint24 (>=0<=16777214),kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating,5,0,1,121,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.nrgconscomp,energy consumption compressor,uint24 (>=0<=16777214),kWh,false,sensor.boiler_dhw_energy_consumption_compressor,sensor.boiler_dhw_nrgconscomp,5,9,1,8,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,nrgconscompcooling,energy consumption compressor cooling,uint24 (>=0<=16777214),kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling,5,0,1,123,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,nrgconscomppool,energy consumption compressor pool,uint24 (>=0<=16777214),kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool,5,0,1,125,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,auxelecheatnrgconstotal,total aux elec. heater energy consumption,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal,5,0,1,127,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,uint24 (>=0<=16777214),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating,5,0,1,129,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.auxelecheatnrgcons,aux elec. heater energy consumption,uint24 (>=0<=16777214),kWh,false,sensor.boiler_dhw_aux_elec._heater_energy_consumption,sensor.boiler_dhw_auxelecheatnrgcons,5,9,1,10,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,auxelecheatnrgconspool,aux elec. heater energy consumption pool,uint24 (>=0<=16777214),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool,5,0,1,131,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,nrgsupptotal,total energy supplied,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal,5,0,1,133,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,nrgsuppheating,total energy supplied heating,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating,5,0,1,135,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.nrgsupp,total energy warm supplied,uint24 (>=0<=16777214),kWh,false,sensor.boiler_dhw_total_energy_warm_supplied,sensor.boiler_dhw_nrgsupp,5,9,1,12,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,nrgsuppcooling,total energy supplied cooling,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling,5,0,1,137,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,nrgsupppool,total energy supplied pool,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool,5,0,1,139,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hppower,compressor power output,uint16 (>=0<=3199),kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower,5,0,1/10,141,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hpmaxpower,compressor max power,uint8 (>=0<=100),%,true,number.boiler_compressor_max_power,number.boiler_hpmaxpower,5,0,1,142,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,pvmaxcomp,pv compressor max power,uint8 (>=0<=25),kW,true,number.boiler_pv_compressor_max_power,number.boiler_pvmaxcomp,5,0,1/10,143,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,powerreduction,power reduction,uint8 (>=30<=60),%,true,number.boiler_power_reduction,number.boiler_powerreduction,5,0,10,144,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hpsetdiffpress,set differential pressure,uint8 (>=150<=750),mbar,true,number.boiler_set_differential_pressure,number.boiler_hpsetdiffpress,5,0,50,145,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hpcompon,hp compressor,boolean, ,false,binary_sensor.boiler_hp_compressor,binary_sensor.boiler_hpcompon,5,0,1,146,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hpactivity,compressor activity,enum [off\|heating\|cooling\|hot water\|pool\|pool heating\|defrost\|compressor alarm], ,false,sensor.boiler_compressor_activity,sensor.boiler_hpactivity,5,0,1,147,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hpbrinepumpspd,brine pump speed,uint8 (>=0<=100),%,false,sensor.boiler_brine_pump_speed,sensor.boiler_hpbrinepumpspd,5,0,1,148,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hpswitchvalve,switch valve,boolean, ,false,binary_sensor.boiler_switch_valve,binary_sensor.boiler_hpswitchvalve,5,0,1,149,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hpcompspd,compressor speed,uint8 (>=0<=100),%,false,sensor.boiler_compressor_speed,sensor.boiler_hpcompspd,5,0,1,150,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hpcircspd,circulation pump speed,uint8 (>=0<=100),%,false,sensor.boiler_circulation_pump_speed,sensor.boiler_hpcircspd,5,0,1,151,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hpbrinein,brine in/evaporator,int16 (>=-3199<=3199),C,false,sensor.boiler_brine_in/evaporator,sensor.boiler_hpbrinein,5,0,1/10,152,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hpbrineout,brine out/condenser,int16 (>=-3199<=3199),C,false,sensor.boiler_brine_out/condenser,sensor.boiler_hpbrineout,5,0,1/10,153,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hptc0,heat carrier return (TC0),int16 (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_return_(TC0),sensor.boiler_hptc0,5,0,1/10,154,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hptc1,heat carrier forward (TC1),int16 (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_forward_(TC1),sensor.boiler_hptc1,5,0,1/10,155,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hptc3,condenser temperature (TC3),int16 (>=-3199<=3199),C,false,sensor.boiler_condenser_temperature_(TC3),sensor.boiler_hptc3,5,0,1/10,156,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hptr1,compressor temperature (TR1),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_temperature_(TR1),sensor.boiler_hptr1,5,0,1/10,157,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hptr3,refrigerant temperature liquid side (condenser output) (TR3),int16 (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.boiler_hptr3,5,0,1/10,158,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hptr4,evaporator inlet temperature (TR4),int16 (>=-3199<=3199),C,false,sensor.boiler_evaporator_inlet_temperature_(TR4),sensor.boiler_hptr4,5,0,1/10,159,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hptr5,compressor inlet temperature (TR5),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_inlet_temperature_(TR5),sensor.boiler_hptr5,5,0,1/10,160,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hptr6,compressor outlet temperature (TR6),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_outlet_temperature_(TR6),sensor.boiler_hptr6,5,0,1/10,161,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hptr7,refrigerant temperature gas side (condenser input) (TR7),int16 (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7),sensor.boiler_hptr7,5,0,1/10,162,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hptl2,air inlet temperature (TL2),int16 (>=-3199<=3199),C,false,sensor.boiler_air_inlet_temperature_(TL2),sensor.boiler_hptl2,5,0,1/10,163,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hppl1,low pressure side temperature (PL1),int16 (>=-3199<=3199),C,false,sensor.boiler_low_pressure_side_temperature_(PL1),sensor.boiler_hppl1,5,0,1/10,164,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hpph1,high pressure side temperature (PH1),int16 (>=-3199<=3199),C,false,sensor.boiler_high_pressure_side_temperature_(PH1),sensor.boiler_hpph1,5,0,1/10,165,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hpta4,drain pan temp (TA4),int16 (>=-3199<=3199),C,false,sensor.boiler_drain_pan_temp_(TA4),sensor.boiler_hpta4,5,0,1/10,166,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hptw1,reservoir temp (TW1),int16 (>=-3199<=3199),C,false,sensor.boiler_reservoir_temp_(TW1),sensor.boiler_hptw1,5,0,1/10,167,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,poolsettemp,pool set temperature,uint8 (>=0<=127),C,true,number.boiler_pool_set_temperature,number.boiler_poolsettemp,5,0,1/2,168,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hp4way,4-way valve (VR4),enum [cooling & defrost\|heating & dhw], ,false,sensor.boiler_4-way_valve_(VR4),sensor.boiler_hp4way,5,0,1,169,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hpin1,input 1 state,boolean, ,false,binary_sensor.boiler_input_1_state,binary_sensor.boiler_hpin1,5,0,1,170,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hpin1opt,input 1 options,string, ,true,sensor.boiler_input_1_options,sensor.boiler_hpin1opt,5,0,1,171,8
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hpin2,input 2 state,boolean, ,false,binary_sensor.boiler_input_2_state,binary_sensor.boiler_hpin2,5,0,1,179,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hpin2opt,input 2 options,string, ,true,sensor.boiler_input_2_options,sensor.boiler_hpin2opt,5,0,1,180,8
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hpin3,input 3 state,boolean, ,false,binary_sensor.boiler_input_3_state,binary_sensor.boiler_hpin3,5,0,1,188,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hpin3opt,input 3 options,string, ,true,sensor.boiler_input_3_options,sensor.boiler_hpin3opt,5,0,1,189,8
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hpin4,input 4 state,boolean, ,false,binary_sensor.boiler_input_4_state,binary_sensor.boiler_hpin4,5,0,1,197,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hpin4opt,input 4 options,string, ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt,5,0,1,198,8
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,maxheatcomp,heat limit compressor,enum [0 kW\|3 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp,5,0,1,206,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,maxheatheat,heat limit heating,enum [3 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat,5,0,1,207,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.maxheat,heat limit,enum [3 kW\|6 kW\|9 kW], ,true,select.boiler_dhw_heat_limit,select.boiler_dhw_maxheat,5,9,1,14,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,auxheatersource,aux heater source,enum [not installed\|electric heater\|exclusive\|parallel\|hybrid], ,true,select.boiler_aux_heater_source,select.boiler_auxheatersource,5,0,1,208,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,pvcooling,cooling only with PV,boolean, ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling,5,0,1,209,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,auxheateronly,aux heater only,boolean, ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly,5,0,1,210,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,auxheateroff,disable aux heater,boolean, ,true,switch.boiler_disable_aux_heater,switch.boiler_auxheateroff,5,0,1,211,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,auxheaterstatus,aux heater status,enum [off\|heating\|cooling\|hot water\|pool\|pool heating\|defrost\|compressor alarm], ,false,sensor.boiler_aux_heater_status,sensor.boiler_auxheaterstatus,5,0,1,212,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,auxheaterlevel,aux heater level,uint8 (>=0<=100),%,false,sensor.boiler_aux_heater_level,sensor.boiler_auxheaterlevel,5,0,1,213,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,auxheaterdelay,aux heater on delay,uint16 (>=10<=1000),K*min,true,number.boiler_aux_heater_on_delay,number.boiler_auxheaterdelay,5,0,10,214,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,auxmaxlimit,aux heater max limit,uint8 (>=0<=10),K,true,number.boiler_aux_heater_max_limit,number.boiler_auxmaxlimit,5,0,1/10,215,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,auxlimitstart,aux heater limit start,uint8 (>=0<=10),K,true,number.boiler_aux_heater_limit_start,number.boiler_auxlimitstart,5,0,1/10,216,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,auxheatrmode,aux heater mode,enum [eco\|comfort], ,true,select.boiler_aux_heater_mode,select.boiler_auxheatrmode,5,0,1,217,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hphystheat,on/off hyst heat,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_heat,number.boiler_hphystheat,5,0,5,218,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hphystcool,on/off hyst cool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_cool,number.boiler_hphystcool,5,0,5,219,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hphystpool,on/off hyst pool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_pool,number.boiler_hphystpool,5,0,5,220,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,silentmode,silent mode,enum [off\|auto\|on], ,true,select.boiler_silent_mode,select.boiler_silentmode,5,0,1,221,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,silentfrom,silent mode from,uint8 (>=0<=3810),minutes,true,number.boiler_silent_mode_from,number.boiler_silentfrom,5,0,15,222,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,silentto,silent mode to,uint8 (>=0<=3810),minutes,true,number.boiler_silent_mode_to,number.boiler_silentto,5,0,15,223,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,mintempsilent,min outside temp for silent mode,int8 (>=-126<=126),C,true,number.boiler_min_outside_temp_for_silent_mode,number.boiler_mintempsilent,5,0,1,224,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,tempparmode,outside temp parallel mode,int8 (>=-126<=126),C,true,number.boiler_outside_temp_parallel_mode,number.boiler_tempparmode,5,0,1,225,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,auxheatmix,aux heater mixing valve,int8 (>=-100<=100),%,false,sensor.boiler_aux_heater_mixing_valve,sensor.boiler_auxheatmix,5,0,1,226,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,tempdiffheat,temp diff TC3/TC0 heat,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_heat,number.boiler_tempdiffheat,5,0,1/10,227,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,tempdiffcool,temp diff TC3/TC0 cool,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_cool,number.boiler_tempdiffcool,5,0,1/10,228,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,vpcooling,valve/pump cooling,boolean, ,true,switch.boiler_valve/pump_cooling,switch.boiler_vpcooling,5,0,1,229,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,heatcable,heating cable,boolean, ,true,switch.boiler_heating_cable,switch.boiler_heatcable,5,0,1,230,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,vc0valve,VC0 valve,boolean, ,true,switch.boiler_VC0_valve,switch.boiler_vc0valve,5,0,1,231,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,primepump,primary heatpump,boolean, ,true,switch.boiler_primary_heatpump,switch.boiler_primepump,5,0,1,232,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,primepumpmod,primary heatpump modulation,uint8 (>=0<=100),%,true,number.boiler_primary_heatpump_modulation,number.boiler_primepumpmod,5,0,1,233,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hp3way,3-way valve,boolean, ,true,switch.boiler_3-way_valve,switch.boiler_hp3way,5,0,1,234,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,elheatstep1,el. heater step 1,boolean, ,true,switch.boiler_el._heater_step_1,switch.boiler_elheatstep1,5,0,1,235,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,elheatstep2,el. heater step 2,boolean, ,true,switch.boiler_el._heater_step_2,switch.boiler_elheatstep2,5,0,1,236,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,elheatstep3,el. heater step 3,boolean, ,true,switch.boiler_el._heater_step_3,switch.boiler_elheatstep3,5,0,1,237,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hpea0,condensate reservoir heating (EA0),boolean, ,false,binary_sensor.boiler_condensate_reservoir_heating_(EA0),binary_sensor.boiler_hpea0,5,0,1,238,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hppumpmode,primary heatpump mode,enum [auto\|continuous], ,true,select.boiler_primary_heatpump_mode,select.boiler_hppumpmode,5,0,1,239,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,fan,fan,uint8 (>=20<=100),%,true,number.boiler_fan,number.boiler_fan,5,0,1,240,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,shutdown,shutdown,cmd [off\|on], ,true,sensor.boiler_shutdown,sensor.boiler_shutdown,5,0,1,241,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hpcurrpower,compressor current power,uint16 (>=0<=31999),W,false,sensor.boiler_compressor_current_power,sensor.boiler_hpcurrpower,5,0,1,242,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,hppowerlimit,power limit,uint16 (>=0<=31999),W,true,number.boiler_power_limit,number.boiler_hppowerlimit,5,0,1,243,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.alternatingop,alternating operation,boolean, ,true,switch.boiler_dhw_alternating_operation,switch.boiler_dhw_alternatingop,5,9,1,15,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.altopprioheat,prioritise heating during dhw,uint8 (>=20<=120),minutes,true,number.boiler_dhw_prioritise_heating_during_dhw,number.boiler_dhw_altopprioheat,5,9,1,16,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.altopprio,prioritise dhw during heating,uint8 (>=30<=120),minutes,true,number.boiler_dhw_prioritise_dhw_during_heating,number.boiler_dhw_altopprio,5,9,1,17,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.comfoff,comfort switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_comfort_switch_off,number.boiler_dhw_comfoff,5,9,1,18,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.ecooff,eco switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_eco_switch_off,number.boiler_dhw_ecooff,5,9,1,19,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.ecoplusoff,eco+ switch off,uint8 (>=48<=63),C,true,number.boiler_dhw_eco+_switch_off,number.boiler_dhw_ecoplusoff,5,9,1,20,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.comfdiff,comfort diff,uint8 (>=4<=12),K,true,number.boiler_dhw_comfort_diff,number.boiler_dhw_comfdiff,5,9,1,21,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.ecodiff,eco diff,uint8 (>=4<=12),K,true,number.boiler_dhw_eco_diff,number.boiler_dhw_ecodiff,5,9,1,22,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.ecoplusdiff,eco+ diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco+_diff,number.boiler_dhw_ecoplusdiff,5,9,1,23,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.comfstop,comfort stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_comfort_stop_temp,number.boiler_dhw_comfstop,5,9,1,24,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.ecostop,eco stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco_stop_temp,number.boiler_dhw_ecostop,5,9,1,25,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.ecoplusstop,eco+ stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco+_stop_temp,number.boiler_dhw_ecoplusstop,5,9,1,26,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.hpcircpump,circulation pump available during dhw,boolean, ,true,switch.boiler_dhw_circulation_pump_available_during_dhw,switch.boiler_dhw_hpcircpump,5,9,1,27,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.chargepump,charge pump,boolean, ,false,binary_sensor.boiler_dhw_charge_pump,binary_sensor.boiler_dhw_chargepump,5,9,1,63,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2
"CS5800iXXX, CS6800i, WLW176i, WLW186i",boiler,8,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2
"Greenstar 2000",boiler,11,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1
"Greenstar 2000",boiler,11,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1
"Greenstar 2000",boiler,11,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1
Can't render this file because it is too large.

View File

@@ -77,7 +77,7 @@ telegram_type_id,name,is_fetched
0x0104,ISM2StatusMessage,
0x010C,IPMStatusMessage,
0x011E,JunkersDisp,fetched
0x012E,HPEnergy1,
0x012E,HPEnergy1XXX,
0x013B,HPEnergy2,
0x0165,JunkersSet,
0x0166,JunkersSet,
1 telegram_type_id name is_fetched
77 0x0104 ISM2StatusMessage
78 0x010C IPMStatusMessage
79 0x011E JunkersDisp fetched
80 0x012E HPEnergy1 HPEnergy1XXX
81 0x013B HPEnergy2
82 0x0165 JunkersSet
83 0x0166 JunkersSet