mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-07 16:29:51 +03:00
update tapwater/heating check
This commit is contained in:
@@ -708,23 +708,29 @@ void Boiler::show_values(uuid::console::Shell & shell) {
|
||||
/*
|
||||
* Check if hot tap water or heating is active
|
||||
* If a value has changed, post it immediately to MQTT so we get real time data
|
||||
* Values will always be posted first time as heatingActive_ and tapwaterActive_ will have values EMS_VALUE_BOOL_NOTSET
|
||||
*/
|
||||
void Boiler::check_active() {
|
||||
if ((boilerState_ == EMS_VALUE_UINT_NOTSET) || ((boilerState_ & 0x09) != (last_boilerState & 0x09))) {
|
||||
bool b;
|
||||
uint8_t val;
|
||||
|
||||
// check if heating is active, bits 2 and 4 must be set
|
||||
b = ((boilerState_ & 0x09) == 0x09);
|
||||
val = b ? EMS_VALUE_BOOL_ON : EMS_VALUE_BOOL_OFF;
|
||||
if (heatingActive_ != val) {
|
||||
heatingActive_ = val;
|
||||
char s[7];
|
||||
bool b = ((boilerState_ & 0x09) == 0x09);
|
||||
Mqtt::publish(F("heating_active"), Helpers::render_boolean(s, b));
|
||||
heatingActive_ = b ? EMS_VALUE_BOOL_ON : EMS_VALUE_BOOL_OFF;
|
||||
last_boilerState = boilerState_;
|
||||
}
|
||||
|
||||
if ((boilerState_ == EMS_VALUE_UINT_NOTSET) || ((boilerState_ & 0x0A) != (last_boilerState & 0x0A))) {
|
||||
// check if tap water is active, bits 1 and 4 must be set
|
||||
b = ((boilerState_ & 0x0A) == 0x0A);
|
||||
val = b ? EMS_VALUE_BOOL_ON : EMS_VALUE_BOOL_OFF;
|
||||
if (tapwaterActive_ != val) {
|
||||
tapwaterActive_ = val;
|
||||
char s[7];
|
||||
bool b = ((boilerState_ & 0x0A) == 0x0A);
|
||||
Mqtt::publish(F("tapwater_active"), Helpers::render_boolean(s, b));
|
||||
tapwaterActive_ = b ? EMS_VALUE_BOOL_ON : EMS_VALUE_BOOL_OFF;
|
||||
EMSESP::tap_water_active(b); // let EMS-ESP know, used in the Shower class
|
||||
last_boilerState = boilerState_;
|
||||
}
|
||||
|
||||
/*
|
||||
|
||||
Reference in New Issue