diff --git a/dump_entities.csv b/dump_entities.csv index a64503415..764a3da89 100644 --- a/dump_entities.csv +++ b/dump_entities.csv @@ -1,103 +1,103 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/max),uom,writeable,discovery entityid v3.4, discovery entityid -CS6800i/WLW176i,boiler,8,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +CS6800i/WLW176i,boiler,8,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset CS6800i/WLW176i,boiler,8,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff CS6800i/WLW176i,boiler,8,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive CS6800i/WLW176i,boiler,8,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -CS6800i/WLW176i,boiler,8,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp -CS6800i/WLW176i,boiler,8,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod -CS6800i/WLW176i,boiler,8,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp -CS6800i/WLW176i,boiler,8,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp -CS6800i/WLW176i,boiler,8,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp -CS6800i/WLW176i,boiler,8,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp -CS6800i/WLW176i,boiler,8,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress -CS6800i/WLW176i,boiler,8,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp -CS6800i/WLW176i,boiler,8,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp +CS6800i/WLW176i,boiler,8,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +CS6800i/WLW176i,boiler,8,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod +CS6800i/WLW176i,boiler,8,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp +CS6800i/WLW176i,boiler,8,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp +CS6800i/WLW176i,boiler,8,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp +CS6800i/WLW176i,boiler,8,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp +CS6800i/WLW176i,boiler,8,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress +CS6800i/WLW176i,boiler,8,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +CS6800i/WLW176i,boiler,8,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp CS6800i/WLW176i,boiler,8,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -CS6800i/WLW176i,boiler,8,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +CS6800i/WLW176i,boiler,8,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp CS6800i/WLW176i,boiler,8,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump -CS6800i/WLW176i,boiler,8,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax -CS6800i/WLW176i,boiler,8,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin +CS6800i/WLW176i,boiler,8,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax +CS6800i/WLW176i,boiler,8,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin CS6800i/WLW176i,boiler,8,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -CS6800i/WLW176i,boiler,8,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -CS6800i/WLW176i,boiler,8,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp -CS6800i/WLW176i,boiler,8,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -CS6800i/WLW176i,boiler,8,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow -CS6800i/WLW176i,boiler,8,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -CS6800i/WLW176i,boiler,8,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +CS6800i/WLW176i,boiler,8,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay +CS6800i/WLW176i,boiler,8,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp +CS6800i/WLW176i,boiler,8,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow +CS6800i/WLW176i,boiler,8,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow +CS6800i/WLW176i,boiler,8,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow +CS6800i/WLW176i,boiler,8,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts CS6800i/WLW176i,boiler,8,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin CS6800i/WLW176i,boiler,8,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin CS6800i/WLW176i,boiler,8,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -CS6800i/WLW176i,boiler,8,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +CS6800i/WLW176i,boiler,8,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts CS6800i/WLW176i,boiler,8,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime CS6800i/WLW176i,boiler,8,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode CS6800i/WLW176i,boiler,8,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode -CS6800i/WLW176i,boiler,8,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber +CS6800i/WLW176i,boiler,8,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber CS6800i/WLW176i,boiler,8,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage CS6800i/WLW176i,boiler,8,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance -CS6800i/WLW176i,boiler,8,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime +CS6800i/WLW176i,boiler,8,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime CS6800i/WLW176i,boiler,8,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate CS6800i/WLW176i,boiler,8,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops -CS6800i/WLW176i,boiler,8,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp -CS6800i/WLW176i,boiler,8,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal -CS6800i/WLW176i,boiler,8,nrgww,energy,ulong (>=0<=167772),kWh,false,sensor.boiler_energy,sensor.boiler_nrgww -CS6800i/WLW176i,boiler,8,nrgheat,energy heating,ulong (>=0<=167772),kWh,false,sensor.boiler_energy_heating,sensor.boiler_nrgheat -CS6800i/WLW176i,boiler,8,metertotal,meter total,ulong (>=0<=167772),kWh,false,sensor.boiler_meter_total,sensor.boiler_metertotal -CS6800i/WLW176i,boiler,8,metercomp,meter compressor,ulong (>=0<=167772),kWh,false,sensor.boiler_meter_compressor,sensor.boiler_metercomp -CS6800i/WLW176i,boiler,8,metereheat,meter e-heater,ulong (>=0<=167772),kWh,false,sensor.boiler_meter_e-heater,sensor.boiler_metereheat -CS6800i/WLW176i,boiler,8,meterheat,meter heating,ulong (>=0<=167772),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat -CS6800i/WLW176i,boiler,8,meterww,meter,ulong (>=0<=167772),kWh,false,sensor.boiler_meter,sensor.boiler_meterww +CS6800i/WLW176i,boiler,8,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp +CS6800i/WLW176i,boiler,8,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +CS6800i/WLW176i,boiler,8,nrgdhw,energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_energy,sensor.boiler_dhw_nrgdhw +CS6800i/WLW176i,boiler,8,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_energy_heating,sensor.boiler_nrgheat +CS6800i/WLW176i,boiler,8,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_total,sensor.boiler_metertotal +CS6800i/WLW176i,boiler,8,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_compressor,sensor.boiler_metercomp +CS6800i/WLW176i,boiler,8,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_e-heater,sensor.boiler_metereheat +CS6800i/WLW176i,boiler,8,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat +CS6800i/WLW176i,boiler,8,meterdhw,meter,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw CS6800i/WLW176i,boiler,8,uptimetotal,heatpump total uptime,time (>=0<=279620),minutes,false,sensor.boiler_heatpump_total_uptime,sensor.boiler_uptimetotal CS6800i/WLW176i,boiler,8,uptimecontrol,total operating time heat,time (>=0<=279620),minutes,false,sensor.boiler_total_operating_time_heat,sensor.boiler_uptimecontrol CS6800i/WLW176i,boiler,8,uptimecompheating,operating time compressor heating,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_heating,sensor.boiler_uptimecompheating CS6800i/WLW176i,boiler,8,uptimecompcooling,operating time compressor cooling,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_cooling,sensor.boiler_uptimecompcooling -CS6800i/WLW176i,boiler,8,uptimecompww,operating time compressor,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor,sensor.boiler_uptimecompww +CS6800i/WLW176i,boiler,8,uptimecompdhw,operating time compressor,time (>=0<=279620),minutes,false,sensor.boiler_dhw_operating_time_compressor,sensor.boiler_dhw_uptimecompdhw CS6800i/WLW176i,boiler,8,uptimecomppool,operating time compressor pool,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_pool,sensor.boiler_uptimecomppool -CS6800i/WLW176i,boiler,8,totalcompstarts,total compressor control starts,ulong (>=0<=16777213), ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts -CS6800i/WLW176i,boiler,8,heatingstarts,heating control starts,ulong (>=0<=16777213), ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts -CS6800i/WLW176i,boiler,8,coolingstarts,cooling control starts,ulong (>=0<=16777213), ,false,sensor.boiler_cooling_control_starts,sensor.boiler_coolingstarts -CS6800i/WLW176i,boiler,8,wwstarts2,control starts2,ulong (>=0<=16777213), ,false,sensor.boiler_control_starts2,sensor.boiler_wwstarts2 -CS6800i/WLW176i,boiler,8,poolstarts,pool control starts,ulong (>=0<=16777213), ,false,sensor.boiler_pool_control_starts,sensor.boiler_poolstarts -CS6800i/WLW176i,boiler,8,nrgconstotal,total energy consumption,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal -CS6800i/WLW176i,boiler,8,nrgconscomptotal,total energy consumption compressor,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal -CS6800i/WLW176i,boiler,8,nrgconscompheating,energy consumption compressor heating,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating -CS6800i/WLW176i,boiler,8,nrgconscompww,energy consumption compressor,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor,sensor.boiler_nrgconscompww -CS6800i/WLW176i,boiler,8,nrgconscompcooling,energy consumption compressor cooling,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling -CS6800i/WLW176i,boiler,8,nrgconscomppool,energy consumption compressor pool,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool -CS6800i/WLW176i,boiler,8,auxelecheatnrgconstotal,total aux elec. heater energy consumption,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal -CS6800i/WLW176i,boiler,8,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,ulong (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating -CS6800i/WLW176i,boiler,8,auxelecheatnrgconsww,aux elec. heater energy consumption,ulong (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconsww -CS6800i/WLW176i,boiler,8,auxelecheatnrgconspool,aux elec. heater energy consumption pool,ulong (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool -CS6800i/WLW176i,boiler,8,nrgsupptotal,total energy supplied,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal -CS6800i/WLW176i,boiler,8,nrgsuppheating,total energy supplied heating,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating -CS6800i/WLW176i,boiler,8,nrgsuppww,total energy warm supplied,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_warm_supplied,sensor.boiler_nrgsuppww -CS6800i/WLW176i,boiler,8,nrgsuppcooling,total energy supplied cooling,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling -CS6800i/WLW176i,boiler,8,nrgsupppool,total energy supplied pool,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool -CS6800i/WLW176i,boiler,8,hppower,compressor power output,uint (>=0<=25),kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower -CS6800i/WLW176i,boiler,8,hpmaxpower,compressor max power,uint (>=0<=100),%,true,number.boiler_compressor_max_power,number.boiler_hpmaxpower -CS6800i/WLW176i,boiler,8,hpsetdiffpress,set differental pressure,uint (>=150<=750),mbar,true,number.boiler_set_differental_pressure,number.boiler_hpsetdiffpress +CS6800i/WLW176i,boiler,8,totalcompstarts,total compressor control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts +CS6800i/WLW176i,boiler,8,heatingstarts,heating control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts +CS6800i/WLW176i,boiler,8,coolingstarts,cooling control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_cooling_control_starts,sensor.boiler_coolingstarts +CS6800i/WLW176i,boiler,8,starts2,control starts2,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_control_starts2,sensor.boiler_dhw_starts2 +CS6800i/WLW176i,boiler,8,poolstarts,pool control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_pool_control_starts,sensor.boiler_poolstarts +CS6800i/WLW176i,boiler,8,nrgconstotal,total energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal +CS6800i/WLW176i,boiler,8,nrgconscomptotal,total energy consumption compressor,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal +CS6800i/WLW176i,boiler,8,nrgconscompheating,energy consumption compressor heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating +CS6800i/WLW176i,boiler,8,nrgconscompdhw,energy consumption compressor,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_energy_consumption_compressor,sensor.boiler_dhw_nrgconscompdhw +CS6800i/WLW176i,boiler,8,nrgconscompcooling,energy consumption compressor cooling,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling +CS6800i/WLW176i,boiler,8,nrgconscomppool,energy consumption compressor pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool +CS6800i/WLW176i,boiler,8,auxelecheatnrgconstotal,total aux elec. heater energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal +CS6800i/WLW176i,boiler,8,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating +CS6800i/WLW176i,boiler,8,auxelecheatnrgconsdhw,aux elec. heater energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_aux_elec._heater_energy_consumption,sensor.boiler_dhw_auxelecheatnrgconsdhw +CS6800i/WLW176i,boiler,8,auxelecheatnrgconspool,aux elec. heater energy consumption pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool +CS6800i/WLW176i,boiler,8,nrgsupptotal,total energy supplied,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal +CS6800i/WLW176i,boiler,8,nrgsuppheating,total energy supplied heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating +CS6800i/WLW176i,boiler,8,nrgsuppdhw,total energy warm supplied,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_total_energy_warm_supplied,sensor.boiler_dhw_nrgsuppdhw +CS6800i/WLW176i,boiler,8,nrgsuppcooling,total energy supplied cooling,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling +CS6800i/WLW176i,boiler,8,nrgsupppool,total energy supplied pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool +CS6800i/WLW176i,boiler,8,hppower,compressor power output,uint8 (>=0<=25),kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower +CS6800i/WLW176i,boiler,8,hpmaxpower,compressor max power,uint8 (>=0<=100),%,true,number.boiler_compressor_max_power,number.boiler_hpmaxpower +CS6800i/WLW176i,boiler,8,hpsetdiffpress,set differental pressure,uint8 (>=150<=750),mbar,true,number.boiler_set_differental_pressure,number.boiler_hpsetdiffpress CS6800i/WLW176i,boiler,8,hpcompon,hp compressor,boolean, ,false,binary_sensor.boiler_hp_compressor,binary_sensor.boiler_hpcompon CS6800i/WLW176i,boiler,8,hpactivity,compressor activity,enum [none\|heating\|cooling\|hot water\|pool\|unknown\|defrost], ,false,sensor.boiler_compressor_activity,sensor.boiler_hpactivity -CS6800i/WLW176i,boiler,8,hpbrinepumpspd,brine pump speed,uint (>=0<=100),%,false,sensor.boiler_brine_pump_speed,sensor.boiler_hpbrinepumpspd +CS6800i/WLW176i,boiler,8,hpbrinepumpspd,brine pump speed,uint8 (>=0<=100),%,false,sensor.boiler_brine_pump_speed,sensor.boiler_hpbrinepumpspd CS6800i/WLW176i,boiler,8,hpswitchvalve,switch valve,boolean, ,false,binary_sensor.boiler_switch_valve,binary_sensor.boiler_hpswitchvalve -CS6800i/WLW176i,boiler,8,hpcompspd,compressor speed,uint (>=0<=100),%,false,sensor.boiler_compressor_speed,sensor.boiler_hpcompspd -CS6800i/WLW176i,boiler,8,hpcircspd,circulation pump speed,uint (>=0<=100),%,false,sensor.boiler_circulation_pump_speed,sensor.boiler_hpcircspd -CS6800i/WLW176i,boiler,8,hpbrinein,brine in/evaporator,short (>=-3199<=3199),C,false,sensor.boiler_brine_in/evaporator,sensor.boiler_hpbrinein -CS6800i/WLW176i,boiler,8,hpbrineout,brine out/condenser,short (>=-3199<=3199),C,false,sensor.boiler_brine_out/condenser,sensor.boiler_hpbrineout -CS6800i/WLW176i,boiler,8,hptc0,heat carrier return (TC0),short (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_return_(TC0),sensor.boiler_hptc0 -CS6800i/WLW176i,boiler,8,hptc1,heat carrier forward (TC1),short (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_forward_(TC1),sensor.boiler_hptc1 -CS6800i/WLW176i,boiler,8,hptc3,condenser temperature (TC3),short (>=-3199<=3199),C,false,sensor.boiler_condenser_temperature_(TC3),sensor.boiler_hptc3 -CS6800i/WLW176i,boiler,8,hptr1,compressor temperature (TR1),short (>=-3199<=3199),C,false,sensor.boiler_compressor_temperature_(TR1),sensor.boiler_hptr1 -CS6800i/WLW176i,boiler,8,hptr3,refrigerant temperature liquid side (condenser output) (TR3),short (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.boiler_hptr3 -CS6800i/WLW176i,boiler,8,hptr4,evaporator inlet temperature (TR4),short (>=-3199<=3199),C,false,sensor.boiler_evaporator_inlet_temperature_(TR4),sensor.boiler_hptr4 -CS6800i/WLW176i,boiler,8,hptr5,compressor inlet temperature (TR5),short (>=-3199<=3199),C,false,sensor.boiler_compressor_inlet_temperature_(TR5),sensor.boiler_hptr5 -CS6800i/WLW176i,boiler,8,hptr6,compressor outlet temperature (TR6),short (>=-3199<=3199),C,false,sensor.boiler_compressor_outlet_temperature_(TR6),sensor.boiler_hptr6 -CS6800i/WLW176i,boiler,8,hptr7,refrigerant temperature gas side (condenser input) (TR7),short (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7),sensor.boiler_hptr7 -CS6800i/WLW176i,boiler,8,hptl2,air inlet temperature (TL2),short (>=-3199<=3199),C,false,sensor.boiler_air_inlet_temperature_(TL2),sensor.boiler_hptl2 -CS6800i/WLW176i,boiler,8,hppl1,low pressure side temperature (PL1),short (>=-3199<=3199),C,false,sensor.boiler_low_pressure_side_temperature_(PL1),sensor.boiler_hppl1 -CS6800i/WLW176i,boiler,8,hpph1,high pressure side temperature (PH1),short (>=-3199<=3199),C,false,sensor.boiler_high_pressure_side_temperature_(PH1),sensor.boiler_hpph1 -CS6800i/WLW176i,boiler,8,hpta4,drain pan temp (TA4),short (>=-3199<=3199),C,false,sensor.boiler_drain_pan_temp_(TA4),sensor.boiler_hpta4 -CS6800i/WLW176i,boiler,8,hptw1,reservoir temp (TW1),short (>=-3199<=3199),C,false,sensor.boiler_reservoir_temp_(TW1),sensor.boiler_hptw1 -CS6800i/WLW176i,boiler,8,poolsettemp,pool set temperature,uint (>=0<=127),C,true,number.boiler_pool_set_temperature,number.boiler_poolsettemp +CS6800i/WLW176i,boiler,8,hpcompspd,compressor speed,uint8 (>=0<=100),%,false,sensor.boiler_compressor_speed,sensor.boiler_hpcompspd +CS6800i/WLW176i,boiler,8,hpcircspd,circulation pump speed,uint8 (>=0<=100),%,false,sensor.boiler_circulation_pump_speed,sensor.boiler_hpcircspd +CS6800i/WLW176i,boiler,8,hpbrinein,brine in/evaporator,int16 (>=-3199<=3199),C,false,sensor.boiler_brine_in/evaporator,sensor.boiler_hpbrinein +CS6800i/WLW176i,boiler,8,hpbrineout,brine out/condenser,int16 (>=-3199<=3199),C,false,sensor.boiler_brine_out/condenser,sensor.boiler_hpbrineout +CS6800i/WLW176i,boiler,8,hptc0,heat carrier return (TC0),int16 (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_return_(TC0),sensor.boiler_hptc0 +CS6800i/WLW176i,boiler,8,hptc1,heat carrier forward (TC1),int16 (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_forward_(TC1),sensor.boiler_hptc1 +CS6800i/WLW176i,boiler,8,hptc3,condenser temperature (TC3),int16 (>=-3199<=3199),C,false,sensor.boiler_condenser_temperature_(TC3),sensor.boiler_hptc3 +CS6800i/WLW176i,boiler,8,hptr1,compressor temperature (TR1),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_temperature_(TR1),sensor.boiler_hptr1 +CS6800i/WLW176i,boiler,8,hptr3,refrigerant temperature liquid side (condenser output) (TR3),int16 (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.boiler_hptr3 +CS6800i/WLW176i,boiler,8,hptr4,evaporator inlet temperature (TR4),int16 (>=-3199<=3199),C,false,sensor.boiler_evaporator_inlet_temperature_(TR4),sensor.boiler_hptr4 +CS6800i/WLW176i,boiler,8,hptr5,compressor inlet temperature (TR5),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_inlet_temperature_(TR5),sensor.boiler_hptr5 +CS6800i/WLW176i,boiler,8,hptr6,compressor outlet temperature (TR6),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_outlet_temperature_(TR6),sensor.boiler_hptr6 +CS6800i/WLW176i,boiler,8,hptr7,refrigerant temperature gas side (condenser input) (TR7),int16 (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7),sensor.boiler_hptr7 +CS6800i/WLW176i,boiler,8,hptl2,air inlet temperature (TL2),int16 (>=-3199<=3199),C,false,sensor.boiler_air_inlet_temperature_(TL2),sensor.boiler_hptl2 +CS6800i/WLW176i,boiler,8,hppl1,low pressure side temperature (PL1),int16 (>=-3199<=3199),C,false,sensor.boiler_low_pressure_side_temperature_(PL1),sensor.boiler_hppl1 +CS6800i/WLW176i,boiler,8,hpph1,high pressure side temperature (PH1),int16 (>=-3199<=3199),C,false,sensor.boiler_high_pressure_side_temperature_(PH1),sensor.boiler_hpph1 +CS6800i/WLW176i,boiler,8,hpta4,drain pan temp (TA4),int16 (>=-3199<=3199),C,false,sensor.boiler_drain_pan_temp_(TA4),sensor.boiler_hpta4 +CS6800i/WLW176i,boiler,8,hptw1,reservoir temp (TW1),int16 (>=-3199<=3199),C,false,sensor.boiler_reservoir_temp_(TW1),sensor.boiler_hptw1 +CS6800i/WLW176i,boiler,8,poolsettemp,pool set temperature,uint8 (>=0<=127),C,true,number.boiler_pool_set_temperature,number.boiler_poolsettemp CS6800i/WLW176i,boiler,8,hp4way,4-way valve (VR4),enum [cooling & defrost\|heating & dhw], ,false,sensor.boiler_4-way_valve_(VR4),sensor.boiler_hp4way CS6800i/WLW176i,boiler,8,hpin1opt,input 1 options,string, ,true,sensor.boiler_input_1_options,sensor.boiler_hpin1opt CS6800i/WLW176i,boiler,8,hpin2opt,input 2 options,string, ,true,sensor.boiler_input_2_options,sensor.boiler_hpin2opt @@ -105,1975 +105,2079 @@ CS6800i/WLW176i,boiler,8,hpin3opt,input 3 options,string, ,true,sensor.boiler_in CS6800i/WLW176i,boiler,8,hpin4opt,input 4 options,string, ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt CS6800i/WLW176i,boiler,8,maxheatcomp,heat limit compressor,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp CS6800i/WLW176i,boiler,8,maxheatheat,heat limit heating,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat -CS6800i/WLW176i,boiler,8,maxheatdhw,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit,select.boiler_maxheatdhw +CS6800i/WLW176i,boiler,8,maxheatdhw,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_dhw_heat_limit,select.boiler_dhw_maxheatdhw CS6800i/WLW176i,boiler,8,mandefrost,manual defrost,boolean, ,true,switch.boiler_manual_defrost,switch.boiler_mandefrost CS6800i/WLW176i,boiler,8,pvcooling,cooling only with PV,boolean, ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling CS6800i/WLW176i,boiler,8,auxheateronly,aux heater only,boolean, ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly CS6800i/WLW176i,boiler,8,auxheateroff,disable aux heater,boolean, ,true,switch.boiler_disable_aux_heater,switch.boiler_auxheateroff -CS6800i/WLW176i,boiler,8,auxheaterstatus,aux heater status,boolean, ,false,binary_sensor.boiler_aux_heater_status,binary_sensor.boiler_auxheaterstatus -CS6800i/WLW176i,boiler,8,auxheaterdelay,aux heater on delay,ushort (>=10<=1000),K*min,true,number.boiler_aux_heater_on_delay,number.boiler_auxheaterdelay -CS6800i/WLW176i,boiler,8,auxmaxlimit,aux heater max limit,uint (>=0<=10),K,true,number.boiler_aux_heater_max_limit,number.boiler_auxmaxlimit -CS6800i/WLW176i,boiler,8,auxlimitstart,aux heater limit start,uint (>=0<=10),K,true,number.boiler_aux_heater_limit_start,number.boiler_auxlimitstart +CS6800i/WLW176i,boiler,8,auxheaterstatus,aux heater status,uint8 (>=0<=100),%,false,sensor.boiler_aux_heater_status,sensor.boiler_auxheaterstatus +CS6800i/WLW176i,boiler,8,auxheaterdelay,aux heater on delay,uint16 (>=10<=1000),K*min,true,number.boiler_aux_heater_on_delay,number.boiler_auxheaterdelay +CS6800i/WLW176i,boiler,8,auxmaxlimit,aux heater max limit,uint8 (>=0<=10),K,true,number.boiler_aux_heater_max_limit,number.boiler_auxmaxlimit +CS6800i/WLW176i,boiler,8,auxlimitstart,aux heater limit start,uint8 (>=0<=10),K,true,number.boiler_aux_heater_limit_start,number.boiler_auxlimitstart CS6800i/WLW176i,boiler,8,auxheatrmode,aux heater mode,enum [eco\|comfort], ,true,select.boiler_aux_heater_mode,select.boiler_auxheatrmode -CS6800i/WLW176i,boiler,8,hphystheat,on/off hyst heat,ushort (>=50<=1500),K*min,true,number.boiler_on/off_hyst_heat,number.boiler_hphystheat -CS6800i/WLW176i,boiler,8,hphystcool,on/off hyst cool,ushort (>=50<=1500),K*min,true,number.boiler_on/off_hyst_cool,number.boiler_hphystcool -CS6800i/WLW176i,boiler,8,hphystpool,on/off hyst pool,ushort (>=50<=1500),K*min,true,number.boiler_on/off_hyst_pool,number.boiler_hphystpool +CS6800i/WLW176i,boiler,8,hphystheat,on/off hyst heat,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_heat,number.boiler_hphystheat +CS6800i/WLW176i,boiler,8,hphystcool,on/off hyst cool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_cool,number.boiler_hphystcool +CS6800i/WLW176i,boiler,8,hphystpool,on/off hyst pool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_pool,number.boiler_hphystpool CS6800i/WLW176i,boiler,8,silentmode,silent mode,enum [off\|auto\|on], ,true,select.boiler_silent_mode,select.boiler_silentmode -CS6800i/WLW176i,boiler,8,silentfrom,silent mode from,uint (>=0<=3810),minutes,true,number.boiler_silent_mode_from,number.boiler_silentfrom -CS6800i/WLW176i,boiler,8,silentto,silent mode to,uint (>=0<=3810),minutes,true,number.boiler_silent_mode_to,number.boiler_silentto -CS6800i/WLW176i,boiler,8,mintempsilent,min outside temp for silent mode,int (>=-126<=126),C,true,number.boiler_min_outside_temp_for_silent_mode,number.boiler_mintempsilent -CS6800i/WLW176i,boiler,8,tempparmode,outside temp parallel mode,int (>=-126<=126),C,true,number.boiler_outside_temp_parallel_mode,number.boiler_tempparmode -CS6800i/WLW176i,boiler,8,auxheatmix,aux heater mixing valve,int (>=-100<=100),%,false,sensor.boiler_aux_heater_mixing_valve,sensor.boiler_auxheatmix -CS6800i/WLW176i,boiler,8,tempdiffheat,temp diff TC3/TC0 heat,uint (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_heat,number.boiler_tempdiffheat -CS6800i/WLW176i,boiler,8,tempdiffcool,temp diff TC3/TC0 cool,uint (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_cool,number.boiler_tempdiffcool +CS6800i/WLW176i,boiler,8,silentfrom,silent mode from,uint8 (>=0<=3810),minutes,true,number.boiler_silent_mode_from,number.boiler_silentfrom +CS6800i/WLW176i,boiler,8,silentto,silent mode to,uint8 (>=0<=3810),minutes,true,number.boiler_silent_mode_to,number.boiler_silentto +CS6800i/WLW176i,boiler,8,mintempsilent,min outside temp for silent mode,int8 (>=-126<=126),C,true,number.boiler_min_outside_temp_for_silent_mode,number.boiler_mintempsilent +CS6800i/WLW176i,boiler,8,tempparmode,outside temp parallel mode,int8 (>=-126<=126),C,true,number.boiler_outside_temp_parallel_mode,number.boiler_tempparmode +CS6800i/WLW176i,boiler,8,auxheatmix,aux heater mixing valve,int8 (>=-100<=100),%,false,sensor.boiler_aux_heater_mixing_valve,sensor.boiler_auxheatmix +CS6800i/WLW176i,boiler,8,tempdiffheat,temp diff TC3/TC0 heat,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_heat,number.boiler_tempdiffheat +CS6800i/WLW176i,boiler,8,tempdiffcool,temp diff TC3/TC0 cool,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_cool,number.boiler_tempdiffcool CS6800i/WLW176i,boiler,8,vpcooling,valve/pump cooling,boolean, ,true,switch.boiler_valve/pump_cooling,switch.boiler_vpcooling CS6800i/WLW176i,boiler,8,heatcable,heating cable,boolean, ,true,switch.boiler_heating_cable,switch.boiler_heatcable CS6800i/WLW176i,boiler,8,vc0valve,VC0 valve,boolean, ,true,switch.boiler_VC0_valve,switch.boiler_vc0valve CS6800i/WLW176i,boiler,8,primepump,primary heatpump,boolean, ,true,switch.boiler_primary_heatpump,switch.boiler_primepump -CS6800i/WLW176i,boiler,8,primepumpmod,primary heatpump modulation,uint (>=0<=100),%,true,number.boiler_primary_heatpump_modulation,number.boiler_primepumpmod +CS6800i/WLW176i,boiler,8,primepumpmod,primary heatpump modulation,uint8 (>=0<=100),%,true,number.boiler_primary_heatpump_modulation,number.boiler_primepumpmod CS6800i/WLW176i,boiler,8,hp3way,3-way valve,boolean, ,true,switch.boiler_3-way_valve,switch.boiler_hp3way CS6800i/WLW176i,boiler,8,elheatstep1,el. heater step 1,boolean, ,true,switch.boiler_el._heater_step_1,switch.boiler_elheatstep1 CS6800i/WLW176i,boiler,8,elheatstep2,el. heater step 2,boolean, ,true,switch.boiler_el._heater_step_2,switch.boiler_elheatstep2 CS6800i/WLW176i,boiler,8,elheatstep3,el. heater step 3,boolean, ,true,switch.boiler_el._heater_step_3,switch.boiler_elheatstep3 CS6800i/WLW176i,boiler,8,hpea0,condensate reservoir heating (EA0),boolean, ,false,binary_sensor.boiler_condensate_reservoir_heating_(EA0),binary_sensor.boiler_hpea0 CS6800i/WLW176i,boiler,8,hppumpmode,primary heatpump mode,enum [auto\|continuous], ,true,select.boiler_primary_heatpump_mode,select.boiler_hppumpmode -CS6800i/WLW176i,boiler,8,wwalternatingop,alternating operation,boolean, ,true,switch.boiler_alternating_operation,switch.boiler_wwalternatingop -CS6800i/WLW176i,boiler,8,wwaltopprioheat,prioritise heating during dhw,uint (>=20<=120),minutes,true,number.boiler_prioritise_heating_during_dhw,number.boiler_wwaltopprioheat -CS6800i/WLW176i,boiler,8,wwaltopprioww,prioritise dhw during heating,uint (>=30<=120),minutes,true,number.boiler_prioritise_dhw_during_heating,number.boiler_wwaltopprioww -CS6800i/WLW176i,boiler,8,wwcomfoff,comfort switch off,uint (>=15<=65),C,true,number.boiler_comfort_switch_off,number.boiler_wwcomfoff -CS6800i/WLW176i,boiler,8,wwecooff,eco switch off,uint (>=15<=65),C,true,number.boiler_eco_switch_off,number.boiler_wwecooff -CS6800i/WLW176i,boiler,8,wwecoplusoff,eco+ switch off,uint (>=48<=63),C,true,number.boiler_eco+_switch_off,number.boiler_wwecoplusoff -CS6800i/WLW176i,boiler,8,wwcomfdiff,comfort diff,uint (>=6<=12),K,true,number.boiler_comfort_diff,number.boiler_wwcomfdiff -CS6800i/WLW176i,boiler,8,wwecodiff,eco diff,uint (>=6<=12),K,true,number.boiler_eco_diff,number.boiler_wwecodiff -CS6800i/WLW176i,boiler,8,wwecoplusdiff,eco+ diff,uint (>=6<=12),K,true,number.boiler_eco+_diff,number.boiler_wwecoplusdiff -CS6800i/WLW176i,boiler,8,wwcomfstop,comfort stop temp,uint (>=0<=254),C,true,number.boiler_comfort_stop_temp,number.boiler_wwcomfstop -CS6800i/WLW176i,boiler,8,wwecostop,eco stop temp,uint (>=0<=254),C,true,number.boiler_eco_stop_temp,number.boiler_wwecostop -CS6800i/WLW176i,boiler,8,wwecoplusstop,eco+ stop temp,uint (>=0<=254),C,true,number.boiler_eco+_stop_temp,number.boiler_wwecoplusstop -CS6800i/WLW176i,boiler,8,hpcircpumpww,circulation pump available during dhw,boolean, ,true,switch.boiler_circulation_pump_available_during_dhw,switch.boiler_hpcircpumpww -CS6800i/WLW176i,boiler,8,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated -CS6800i/WLW176i,boiler,8,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp -CS6800i/WLW176i,boiler,8,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp -CS6800i/WLW176i,boiler,8,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow -CS6800i/WLW176i,boiler,8,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus -CS6800i/WLW176i,boiler,8,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff -CS6800i/WLW176i,boiler,8,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle -CS6800i/WLW176i,boiler,8,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp -CS6800i/WLW176i,boiler,8,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype -CS6800i/WLW176i,boiler,8,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort -CS6800i/WLW176i,boiler,8,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 -CS6800i/WLW176i,boiler,8,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset -CS6800i/WLW176i,boiler,8,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization -CS6800i/WLW176i,boiler,8,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -CS6800i/WLW176i,boiler,8,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp -CS6800i/WLW176i,boiler,8,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump -CS6800i/WLW176i,boiler,8,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype -CS6800i/WLW176i,boiler,8,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston -CS6800i/WLW176i,boiler,8,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -CS6800i/WLW176i,boiler,8,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp -CS6800i/WLW176i,boiler,8,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode -CS6800i/WLW176i,boiler,8,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc -CS6800i/WLW176i,boiler,8,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp -CS6800i/WLW176i,boiler,8,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 -CS6800i/WLW176i,boiler,8,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow -CS6800i/WLW176i,boiler,8,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 -CS6800i/WLW176i,boiler,8,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 -CS6800i/WLW176i,boiler,8,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated -CS6800i/WLW176i,boiler,8,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime -CS6800i/WLW176i,boiler,8,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting -CS6800i/WLW176i,boiler,8,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging -CS6800i/WLW176i,boiler,8,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging -CS6800i/WLW176i,boiler,8,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok -CS6800i/WLW176i,boiler,8,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive -CS6800i/WLW176i,boiler,8,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve -CS6800i/WLW176i,boiler,8,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower -CS6800i/WLW176i,boiler,8,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp -CS6800i/WLW176i,boiler,8,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -CS6800i/WLW176i,boiler,8,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -CS6800i/WLW176i,boiler,8,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -C1200W,boiler,12,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +CS6800i/WLW176i,boiler,8,fan,fan,uint8 (>=20<=100),%,true,number.boiler_fan,number.boiler_fan +CS6800i/WLW176i,boiler,8,shutdown,shutdown,boolean, ,true,switch.boiler_shutdown,switch.boiler_shutdown +CS6800i/WLW176i,boiler,8,alternatingop,alternating operation,boolean, ,true,switch.boiler_dhw_alternating_operation,switch.boiler_dhw_alternatingop +CS6800i/WLW176i,boiler,8,altopprioheat,prioritise heating during dhw,uint8 (>=20<=120),minutes,true,number.boiler_dhw_prioritise_heating_during_dhw,number.boiler_dhw_altopprioheat +CS6800i/WLW176i,boiler,8,altoppriodhw,prioritise dhw during heating,uint8 (>=30<=120),minutes,true,number.boiler_dhw_prioritise_dhw_during_heating,number.boiler_dhw_altoppriodhw +CS6800i/WLW176i,boiler,8,comfoff,comfort switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_comfort_switch_off,number.boiler_dhw_comfoff +CS6800i/WLW176i,boiler,8,ecooff,eco switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_eco_switch_off,number.boiler_dhw_ecooff +CS6800i/WLW176i,boiler,8,ecoplusoff,eco+ switch off,uint8 (>=48<=63),C,true,number.boiler_dhw_eco+_switch_off,number.boiler_dhw_ecoplusoff +CS6800i/WLW176i,boiler,8,comfdiff,comfort diff,uint8 (>=6<=12),K,true,number.boiler_dhw_comfort_diff,number.boiler_dhw_comfdiff +CS6800i/WLW176i,boiler,8,ecodiff,eco diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco_diff,number.boiler_dhw_ecodiff +CS6800i/WLW176i,boiler,8,ecoplusdiff,eco+ diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco+_diff,number.boiler_dhw_ecoplusdiff +CS6800i/WLW176i,boiler,8,comfstop,comfort stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_comfort_stop_temp,number.boiler_dhw_comfstop +CS6800i/WLW176i,boiler,8,ecostop,eco stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco_stop_temp,number.boiler_dhw_ecostop +CS6800i/WLW176i,boiler,8,ecoplusstop,eco+ stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco+_stop_temp,number.boiler_dhw_ecoplusstop +CS6800i/WLW176i,boiler,8,hpcircpumpdhw,circulation pump available during dhw,boolean, ,true,switch.boiler_dhw_circulation_pump_available_during_dhw,switch.boiler_dhw_hpcircpumpdhw +CS6800i/WLW176i,boiler,8,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated +CS6800i/WLW176i,boiler,8,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp +CS6800i/WLW176i,boiler,8,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp +CS6800i/WLW176i,boiler,8,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow +CS6800i/WLW176i,boiler,8,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus +CS6800i/WLW176i,boiler,8,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff +CS6800i/WLW176i,boiler,8,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle +CS6800i/WLW176i,boiler,8,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp +CS6800i/WLW176i,boiler,8,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type +CS6800i/WLW176i,boiler,8,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort +CS6800i/WLW176i,boiler,8,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1 +CS6800i/WLW176i,boiler,8,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset +CS6800i/WLW176i,boiler,8,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization +CS6800i/WLW176i,boiler,8,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower +CS6800i/WLW176i,boiler,8,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp +CS6800i/WLW176i,boiler,8,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump +CS6800i/WLW176i,boiler,8,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype +CS6800i/WLW176i,boiler,8,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston +CS6800i/WLW176i,boiler,8,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff +CS6800i/WLW176i,boiler,8,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp +CS6800i/WLW176i,boiler,8,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode +CS6800i/WLW176i,boiler,8,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ +CS6800i/WLW176i,boiler,8,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp +CS6800i/WLW176i,boiler,8,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2 +CS6800i/WLW176i,boiler,8,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow +CS6800i/WLW176i,boiler,8,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1 +CS6800i/WLW176i,boiler,8,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2 +CS6800i/WLW176i,boiler,8,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated +CS6800i/WLW176i,boiler,8,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime +CS6800i/WLW176i,boiler,8,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting +CS6800i/WLW176i,boiler,8,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging +CS6800i/WLW176i,boiler,8,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging +CS6800i/WLW176i,boiler,8,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok +CS6800i/WLW176i,boiler,8,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active +CS6800i/WLW176i,boiler,8,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve +CS6800i/WLW176i,boiler,8,setpumppower,set pump power,uint8 (>=0<=100),%,false,sensor.boiler_dhw_set_pump_power,sensor.boiler_dhw_setpumppower +CS6800i/WLW176i,boiler,8,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp +CS6800i/WLW176i,boiler,8,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp +CS6800i/WLW176i,boiler,8,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts +CS6800i/WLW176i,boiler,8,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm +C1200W,boiler,12,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset C1200W,boiler,12,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff C1200W,boiler,12,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive C1200W,boiler,12,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -C1200W,boiler,12,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp -C1200W,boiler,12,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod -C1200W,boiler,12,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp -C1200W,boiler,12,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp -C1200W,boiler,12,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp -C1200W,boiler,12,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp -C1200W,boiler,12,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress -C1200W,boiler,12,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp -C1200W,boiler,12,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp -C1200W,boiler,12,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp +C1200W,boiler,12,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +C1200W,boiler,12,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod +C1200W,boiler,12,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp +C1200W,boiler,12,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp +C1200W,boiler,12,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp +C1200W,boiler,12,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp +C1200W,boiler,12,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress +C1200W,boiler,12,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +C1200W,boiler,12,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp +C1200W,boiler,12,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp C1200W,boiler,12,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas C1200W,boiler,12,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 -C1200W,boiler,12,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr +C1200W,boiler,12,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr C1200W,boiler,12,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork C1200W,boiler,12,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork C1200W,boiler,12,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat -C1200W,boiler,12,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -C1200W,boiler,12,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -C1200W,boiler,12,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -C1200W,boiler,12,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow -C1200W,boiler,12,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock -C1200W,boiler,12,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -C1200W,boiler,12,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -C1200W,boiler,12,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -C1200W,boiler,12,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +C1200W,boiler,12,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +C1200W,boiler,12,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +C1200W,boiler,12,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +C1200W,boiler,12,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +C1200W,boiler,12,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +C1200W,boiler,12,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +C1200W,boiler,12,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff +C1200W,boiler,12,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston +C1200W,boiler,12,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff C1200W,boiler,12,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon -C1200W,boiler,12,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase -C1200W,boiler,12,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -C1200W,boiler,12,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +C1200W,boiler,12,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase +C1200W,boiler,12,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend +C1200W,boiler,12,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp C1200W,boiler,12,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode -C1200W,boiler,12,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp +C1200W,boiler,12,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp C1200W,boiler,12,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -C1200W,boiler,12,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +C1200W,boiler,12,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp C1200W,boiler,12,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump -C1200W,boiler,12,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax -C1200W,boiler,12,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin +C1200W,boiler,12,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax +C1200W,boiler,12,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin C1200W,boiler,12,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -C1200W,boiler,12,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -C1200W,boiler,12,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp -C1200W,boiler,12,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -C1200W,boiler,12,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow -C1200W,boiler,12,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -C1200W,boiler,12,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +C1200W,boiler,12,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay +C1200W,boiler,12,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp +C1200W,boiler,12,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow +C1200W,boiler,12,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow +C1200W,boiler,12,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow +C1200W,boiler,12,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts C1200W,boiler,12,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin C1200W,boiler,12,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin C1200W,boiler,12,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -C1200W,boiler,12,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +C1200W,boiler,12,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts C1200W,boiler,12,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime C1200W,boiler,12,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode C1200W,boiler,12,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode -C1200W,boiler,12,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber +C1200W,boiler,12,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber C1200W,boiler,12,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage C1200W,boiler,12,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance -C1200W,boiler,12,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime +C1200W,boiler,12,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime C1200W,boiler,12,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate C1200W,boiler,12,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops -C1200W,boiler,12,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp -C1200W,boiler,12,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated -C1200W,boiler,12,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp -C1200W,boiler,12,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp -C1200W,boiler,12,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow -C1200W,boiler,12,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus -C1200W,boiler,12,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff -C1200W,boiler,12,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle -C1200W,boiler,12,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp -C1200W,boiler,12,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype -C1200W,boiler,12,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort -C1200W,boiler,12,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 -C1200W,boiler,12,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset -C1200W,boiler,12,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization -C1200W,boiler,12,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -C1200W,boiler,12,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp -C1200W,boiler,12,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump -C1200W,boiler,12,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype -C1200W,boiler,12,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston -C1200W,boiler,12,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -C1200W,boiler,12,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp -C1200W,boiler,12,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode -C1200W,boiler,12,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc -C1200W,boiler,12,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp -C1200W,boiler,12,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 -C1200W,boiler,12,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow -C1200W,boiler,12,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 -C1200W,boiler,12,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 -C1200W,boiler,12,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated -C1200W,boiler,12,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime -C1200W,boiler,12,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting -C1200W,boiler,12,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging -C1200W,boiler,12,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging -C1200W,boiler,12,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok -C1200W,boiler,12,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive -C1200W,boiler,12,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve -C1200W,boiler,12,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower -C1200W,boiler,12,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp -C1200W,boiler,12,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -C1200W,boiler,12,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -C1200W,boiler,12,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -C1200W,boiler,12,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower -C1200W,boiler,12,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal -C1200W,boiler,12,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -C1200W,boiler,12,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww -BK13/BK15/Smartline/GB1x2,boiler,64,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +C1200W,boiler,12,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp +C1200W,boiler,12,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat +C1200W,boiler,12,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +C1200W,boiler,12,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat +C1200W,boiler,12,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +C1200W,boiler,12,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 +C1200W,boiler,12,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +C1200W,boiler,12,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated +C1200W,boiler,12,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp +C1200W,boiler,12,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp +C1200W,boiler,12,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow +C1200W,boiler,12,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus +C1200W,boiler,12,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff +C1200W,boiler,12,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle +C1200W,boiler,12,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp +C1200W,boiler,12,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type +C1200W,boiler,12,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort +C1200W,boiler,12,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1 +C1200W,boiler,12,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset +C1200W,boiler,12,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization +C1200W,boiler,12,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower +C1200W,boiler,12,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp +C1200W,boiler,12,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump +C1200W,boiler,12,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype +C1200W,boiler,12,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston +C1200W,boiler,12,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff +C1200W,boiler,12,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp +C1200W,boiler,12,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode +C1200W,boiler,12,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ +C1200W,boiler,12,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp +C1200W,boiler,12,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2 +C1200W,boiler,12,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow +C1200W,boiler,12,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1 +C1200W,boiler,12,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2 +C1200W,boiler,12,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated +C1200W,boiler,12,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime +C1200W,boiler,12,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting +C1200W,boiler,12,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging +C1200W,boiler,12,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging +C1200W,boiler,12,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok +C1200W,boiler,12,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active +C1200W,boiler,12,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve +C1200W,boiler,12,setpumppower,set pump power,uint8 (>=0<=100),%,false,sensor.boiler_dhw_set_pump_power,sensor.boiler_dhw_setpumppower +C1200W,boiler,12,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp +C1200W,boiler,12,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp +C1200W,boiler,12,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts +C1200W,boiler,12,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm +C1200W,boiler,12,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +C1200W,boiler,12,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +C1200W,boiler,12,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +C1200W,boiler,12,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +BK13/BK15/Smartline/GB1x2,boiler,64,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset BK13/BK15/Smartline/GB1x2,boiler,64,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff BK13/BK15/Smartline/GB1x2,boiler,64,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive BK13/BK15/Smartline/GB1x2,boiler,64,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -BK13/BK15/Smartline/GB1x2,boiler,64,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp -BK13/BK15/Smartline/GB1x2,boiler,64,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod -BK13/BK15/Smartline/GB1x2,boiler,64,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp -BK13/BK15/Smartline/GB1x2,boiler,64,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp -BK13/BK15/Smartline/GB1x2,boiler,64,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp -BK13/BK15/Smartline/GB1x2,boiler,64,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp -BK13/BK15/Smartline/GB1x2,boiler,64,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress -BK13/BK15/Smartline/GB1x2,boiler,64,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp -BK13/BK15/Smartline/GB1x2,boiler,64,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp -BK13/BK15/Smartline/GB1x2,boiler,64,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp +BK13/BK15/Smartline/GB1x2,boiler,64,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +BK13/BK15/Smartline/GB1x2,boiler,64,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod +BK13/BK15/Smartline/GB1x2,boiler,64,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp +BK13/BK15/Smartline/GB1x2,boiler,64,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp +BK13/BK15/Smartline/GB1x2,boiler,64,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp +BK13/BK15/Smartline/GB1x2,boiler,64,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp +BK13/BK15/Smartline/GB1x2,boiler,64,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress +BK13/BK15/Smartline/GB1x2,boiler,64,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +BK13/BK15/Smartline/GB1x2,boiler,64,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp +BK13/BK15/Smartline/GB1x2,boiler,64,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp BK13/BK15/Smartline/GB1x2,boiler,64,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas BK13/BK15/Smartline/GB1x2,boiler,64,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 -BK13/BK15/Smartline/GB1x2,boiler,64,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr +BK13/BK15/Smartline/GB1x2,boiler,64,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr BK13/BK15/Smartline/GB1x2,boiler,64,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork BK13/BK15/Smartline/GB1x2,boiler,64,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork BK13/BK15/Smartline/GB1x2,boiler,64,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat -BK13/BK15/Smartline/GB1x2,boiler,64,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -BK13/BK15/Smartline/GB1x2,boiler,64,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -BK13/BK15/Smartline/GB1x2,boiler,64,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -BK13/BK15/Smartline/GB1x2,boiler,64,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow -BK13/BK15/Smartline/GB1x2,boiler,64,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock -BK13/BK15/Smartline/GB1x2,boiler,64,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -BK13/BK15/Smartline/GB1x2,boiler,64,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -BK13/BK15/Smartline/GB1x2,boiler,64,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -BK13/BK15/Smartline/GB1x2,boiler,64,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +BK13/BK15/Smartline/GB1x2,boiler,64,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +BK13/BK15/Smartline/GB1x2,boiler,64,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +BK13/BK15/Smartline/GB1x2,boiler,64,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +BK13/BK15/Smartline/GB1x2,boiler,64,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +BK13/BK15/Smartline/GB1x2,boiler,64,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +BK13/BK15/Smartline/GB1x2,boiler,64,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +BK13/BK15/Smartline/GB1x2,boiler,64,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff +BK13/BK15/Smartline/GB1x2,boiler,64,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston +BK13/BK15/Smartline/GB1x2,boiler,64,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff BK13/BK15/Smartline/GB1x2,boiler,64,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon -BK13/BK15/Smartline/GB1x2,boiler,64,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase -BK13/BK15/Smartline/GB1x2,boiler,64,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -BK13/BK15/Smartline/GB1x2,boiler,64,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +BK13/BK15/Smartline/GB1x2,boiler,64,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase +BK13/BK15/Smartline/GB1x2,boiler,64,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend +BK13/BK15/Smartline/GB1x2,boiler,64,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp BK13/BK15/Smartline/GB1x2,boiler,64,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode -BK13/BK15/Smartline/GB1x2,boiler,64,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp +BK13/BK15/Smartline/GB1x2,boiler,64,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp BK13/BK15/Smartline/GB1x2,boiler,64,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -BK13/BK15/Smartline/GB1x2,boiler,64,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +BK13/BK15/Smartline/GB1x2,boiler,64,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp BK13/BK15/Smartline/GB1x2,boiler,64,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump -BK13/BK15/Smartline/GB1x2,boiler,64,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax -BK13/BK15/Smartline/GB1x2,boiler,64,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin +BK13/BK15/Smartline/GB1x2,boiler,64,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax +BK13/BK15/Smartline/GB1x2,boiler,64,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin BK13/BK15/Smartline/GB1x2,boiler,64,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -BK13/BK15/Smartline/GB1x2,boiler,64,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -BK13/BK15/Smartline/GB1x2,boiler,64,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp -BK13/BK15/Smartline/GB1x2,boiler,64,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -BK13/BK15/Smartline/GB1x2,boiler,64,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow -BK13/BK15/Smartline/GB1x2,boiler,64,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -BK13/BK15/Smartline/GB1x2,boiler,64,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +BK13/BK15/Smartline/GB1x2,boiler,64,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay +BK13/BK15/Smartline/GB1x2,boiler,64,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp +BK13/BK15/Smartline/GB1x2,boiler,64,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow +BK13/BK15/Smartline/GB1x2,boiler,64,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow +BK13/BK15/Smartline/GB1x2,boiler,64,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow +BK13/BK15/Smartline/GB1x2,boiler,64,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts BK13/BK15/Smartline/GB1x2,boiler,64,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin BK13/BK15/Smartline/GB1x2,boiler,64,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin BK13/BK15/Smartline/GB1x2,boiler,64,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -BK13/BK15/Smartline/GB1x2,boiler,64,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +BK13/BK15/Smartline/GB1x2,boiler,64,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts BK13/BK15/Smartline/GB1x2,boiler,64,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime BK13/BK15/Smartline/GB1x2,boiler,64,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode BK13/BK15/Smartline/GB1x2,boiler,64,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode -BK13/BK15/Smartline/GB1x2,boiler,64,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber +BK13/BK15/Smartline/GB1x2,boiler,64,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber BK13/BK15/Smartline/GB1x2,boiler,64,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage BK13/BK15/Smartline/GB1x2,boiler,64,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance -BK13/BK15/Smartline/GB1x2,boiler,64,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime +BK13/BK15/Smartline/GB1x2,boiler,64,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime BK13/BK15/Smartline/GB1x2,boiler,64,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate BK13/BK15/Smartline/GB1x2,boiler,64,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops -BK13/BK15/Smartline/GB1x2,boiler,64,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp -BK13/BK15/Smartline/GB1x2,boiler,64,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated -BK13/BK15/Smartline/GB1x2,boiler,64,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp -BK13/BK15/Smartline/GB1x2,boiler,64,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp -BK13/BK15/Smartline/GB1x2,boiler,64,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow -BK13/BK15/Smartline/GB1x2,boiler,64,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus -BK13/BK15/Smartline/GB1x2,boiler,64,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff -BK13/BK15/Smartline/GB1x2,boiler,64,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle -BK13/BK15/Smartline/GB1x2,boiler,64,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp -BK13/BK15/Smartline/GB1x2,boiler,64,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype -BK13/BK15/Smartline/GB1x2,boiler,64,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort -BK13/BK15/Smartline/GB1x2,boiler,64,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 -BK13/BK15/Smartline/GB1x2,boiler,64,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset -BK13/BK15/Smartline/GB1x2,boiler,64,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization -BK13/BK15/Smartline/GB1x2,boiler,64,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -BK13/BK15/Smartline/GB1x2,boiler,64,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp -BK13/BK15/Smartline/GB1x2,boiler,64,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump -BK13/BK15/Smartline/GB1x2,boiler,64,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype -BK13/BK15/Smartline/GB1x2,boiler,64,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston -BK13/BK15/Smartline/GB1x2,boiler,64,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -BK13/BK15/Smartline/GB1x2,boiler,64,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp -BK13/BK15/Smartline/GB1x2,boiler,64,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode -BK13/BK15/Smartline/GB1x2,boiler,64,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc -BK13/BK15/Smartline/GB1x2,boiler,64,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp -BK13/BK15/Smartline/GB1x2,boiler,64,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 -BK13/BK15/Smartline/GB1x2,boiler,64,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow -BK13/BK15/Smartline/GB1x2,boiler,64,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 -BK13/BK15/Smartline/GB1x2,boiler,64,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 -BK13/BK15/Smartline/GB1x2,boiler,64,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated -BK13/BK15/Smartline/GB1x2,boiler,64,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime -BK13/BK15/Smartline/GB1x2,boiler,64,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting -BK13/BK15/Smartline/GB1x2,boiler,64,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging -BK13/BK15/Smartline/GB1x2,boiler,64,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging -BK13/BK15/Smartline/GB1x2,boiler,64,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok -BK13/BK15/Smartline/GB1x2,boiler,64,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive -BK13/BK15/Smartline/GB1x2,boiler,64,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve -BK13/BK15/Smartline/GB1x2,boiler,64,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower -BK13/BK15/Smartline/GB1x2,boiler,64,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp -BK13/BK15/Smartline/GB1x2,boiler,64,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -BK13/BK15/Smartline/GB1x2,boiler,64,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -BK13/BK15/Smartline/GB1x2,boiler,64,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -BK13/BK15/Smartline/GB1x2,boiler,64,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower -BK13/BK15/Smartline/GB1x2,boiler,64,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal -BK13/BK15/Smartline/GB1x2,boiler,64,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -BK13/BK15/Smartline/GB1x2,boiler,64,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww -GB125/GB135/MC10,boiler,72,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +BK13/BK15/Smartline/GB1x2,boiler,64,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp +BK13/BK15/Smartline/GB1x2,boiler,64,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat +BK13/BK15/Smartline/GB1x2,boiler,64,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +BK13/BK15/Smartline/GB1x2,boiler,64,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat +BK13/BK15/Smartline/GB1x2,boiler,64,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +BK13/BK15/Smartline/GB1x2,boiler,64,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 +BK13/BK15/Smartline/GB1x2,boiler,64,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +BK13/BK15/Smartline/GB1x2,boiler,64,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated +BK13/BK15/Smartline/GB1x2,boiler,64,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp +BK13/BK15/Smartline/GB1x2,boiler,64,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp +BK13/BK15/Smartline/GB1x2,boiler,64,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow +BK13/BK15/Smartline/GB1x2,boiler,64,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus +BK13/BK15/Smartline/GB1x2,boiler,64,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff +BK13/BK15/Smartline/GB1x2,boiler,64,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle +BK13/BK15/Smartline/GB1x2,boiler,64,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp +BK13/BK15/Smartline/GB1x2,boiler,64,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type +BK13/BK15/Smartline/GB1x2,boiler,64,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort +BK13/BK15/Smartline/GB1x2,boiler,64,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1 +BK13/BK15/Smartline/GB1x2,boiler,64,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset +BK13/BK15/Smartline/GB1x2,boiler,64,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization +BK13/BK15/Smartline/GB1x2,boiler,64,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower +BK13/BK15/Smartline/GB1x2,boiler,64,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp +BK13/BK15/Smartline/GB1x2,boiler,64,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump +BK13/BK15/Smartline/GB1x2,boiler,64,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype +BK13/BK15/Smartline/GB1x2,boiler,64,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston +BK13/BK15/Smartline/GB1x2,boiler,64,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff +BK13/BK15/Smartline/GB1x2,boiler,64,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp +BK13/BK15/Smartline/GB1x2,boiler,64,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode +BK13/BK15/Smartline/GB1x2,boiler,64,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ +BK13/BK15/Smartline/GB1x2,boiler,64,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp +BK13/BK15/Smartline/GB1x2,boiler,64,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2 +BK13/BK15/Smartline/GB1x2,boiler,64,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow +BK13/BK15/Smartline/GB1x2,boiler,64,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1 +BK13/BK15/Smartline/GB1x2,boiler,64,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2 +BK13/BK15/Smartline/GB1x2,boiler,64,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated +BK13/BK15/Smartline/GB1x2,boiler,64,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime +BK13/BK15/Smartline/GB1x2,boiler,64,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting +BK13/BK15/Smartline/GB1x2,boiler,64,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging +BK13/BK15/Smartline/GB1x2,boiler,64,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging +BK13/BK15/Smartline/GB1x2,boiler,64,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok +BK13/BK15/Smartline/GB1x2,boiler,64,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active +BK13/BK15/Smartline/GB1x2,boiler,64,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve +BK13/BK15/Smartline/GB1x2,boiler,64,setpumppower,set pump power,uint8 (>=0<=100),%,false,sensor.boiler_dhw_set_pump_power,sensor.boiler_dhw_setpumppower +BK13/BK15/Smartline/GB1x2,boiler,64,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp +BK13/BK15/Smartline/GB1x2,boiler,64,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp +BK13/BK15/Smartline/GB1x2,boiler,64,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts +BK13/BK15/Smartline/GB1x2,boiler,64,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm +BK13/BK15/Smartline/GB1x2,boiler,64,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +BK13/BK15/Smartline/GB1x2,boiler,64,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +BK13/BK15/Smartline/GB1x2,boiler,64,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +BK13/BK15/Smartline/GB1x2,boiler,64,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +GB125/GB135/MC10,boiler,72,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset GB125/GB135/MC10,boiler,72,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff GB125/GB135/MC10,boiler,72,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive GB125/GB135/MC10,boiler,72,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -GB125/GB135/MC10,boiler,72,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp -GB125/GB135/MC10,boiler,72,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod -GB125/GB135/MC10,boiler,72,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp -GB125/GB135/MC10,boiler,72,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp -GB125/GB135/MC10,boiler,72,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp -GB125/GB135/MC10,boiler,72,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp -GB125/GB135/MC10,boiler,72,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress -GB125/GB135/MC10,boiler,72,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp -GB125/GB135/MC10,boiler,72,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp -GB125/GB135/MC10,boiler,72,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp +GB125/GB135/MC10,boiler,72,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +GB125/GB135/MC10,boiler,72,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod +GB125/GB135/MC10,boiler,72,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp +GB125/GB135/MC10,boiler,72,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp +GB125/GB135/MC10,boiler,72,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp +GB125/GB135/MC10,boiler,72,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp +GB125/GB135/MC10,boiler,72,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress +GB125/GB135/MC10,boiler,72,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +GB125/GB135/MC10,boiler,72,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp +GB125/GB135/MC10,boiler,72,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp GB125/GB135/MC10,boiler,72,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas GB125/GB135/MC10,boiler,72,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 -GB125/GB135/MC10,boiler,72,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr +GB125/GB135/MC10,boiler,72,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr GB125/GB135/MC10,boiler,72,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork GB125/GB135/MC10,boiler,72,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork GB125/GB135/MC10,boiler,72,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat -GB125/GB135/MC10,boiler,72,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -GB125/GB135/MC10,boiler,72,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -GB125/GB135/MC10,boiler,72,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -GB125/GB135/MC10,boiler,72,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow -GB125/GB135/MC10,boiler,72,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock -GB125/GB135/MC10,boiler,72,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -GB125/GB135/MC10,boiler,72,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -GB125/GB135/MC10,boiler,72,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -GB125/GB135/MC10,boiler,72,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +GB125/GB135/MC10,boiler,72,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +GB125/GB135/MC10,boiler,72,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +GB125/GB135/MC10,boiler,72,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +GB125/GB135/MC10,boiler,72,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +GB125/GB135/MC10,boiler,72,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +GB125/GB135/MC10,boiler,72,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +GB125/GB135/MC10,boiler,72,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff +GB125/GB135/MC10,boiler,72,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston +GB125/GB135/MC10,boiler,72,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff GB125/GB135/MC10,boiler,72,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon -GB125/GB135/MC10,boiler,72,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase -GB125/GB135/MC10,boiler,72,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -GB125/GB135/MC10,boiler,72,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +GB125/GB135/MC10,boiler,72,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase +GB125/GB135/MC10,boiler,72,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend +GB125/GB135/MC10,boiler,72,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp GB125/GB135/MC10,boiler,72,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode -GB125/GB135/MC10,boiler,72,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp +GB125/GB135/MC10,boiler,72,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp GB125/GB135/MC10,boiler,72,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -GB125/GB135/MC10,boiler,72,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +GB125/GB135/MC10,boiler,72,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp GB125/GB135/MC10,boiler,72,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump -GB125/GB135/MC10,boiler,72,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax -GB125/GB135/MC10,boiler,72,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin +GB125/GB135/MC10,boiler,72,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax +GB125/GB135/MC10,boiler,72,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin GB125/GB135/MC10,boiler,72,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -GB125/GB135/MC10,boiler,72,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -GB125/GB135/MC10,boiler,72,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp -GB125/GB135/MC10,boiler,72,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -GB125/GB135/MC10,boiler,72,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow -GB125/GB135/MC10,boiler,72,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -GB125/GB135/MC10,boiler,72,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +GB125/GB135/MC10,boiler,72,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay +GB125/GB135/MC10,boiler,72,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp +GB125/GB135/MC10,boiler,72,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow +GB125/GB135/MC10,boiler,72,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow +GB125/GB135/MC10,boiler,72,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow +GB125/GB135/MC10,boiler,72,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts GB125/GB135/MC10,boiler,72,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin GB125/GB135/MC10,boiler,72,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin GB125/GB135/MC10,boiler,72,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -GB125/GB135/MC10,boiler,72,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +GB125/GB135/MC10,boiler,72,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts GB125/GB135/MC10,boiler,72,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime GB125/GB135/MC10,boiler,72,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode GB125/GB135/MC10,boiler,72,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode -GB125/GB135/MC10,boiler,72,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber +GB125/GB135/MC10,boiler,72,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber GB125/GB135/MC10,boiler,72,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage GB125/GB135/MC10,boiler,72,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance -GB125/GB135/MC10,boiler,72,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime +GB125/GB135/MC10,boiler,72,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime GB125/GB135/MC10,boiler,72,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate GB125/GB135/MC10,boiler,72,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops -GB125/GB135/MC10,boiler,72,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp -GB125/GB135/MC10,boiler,72,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated -GB125/GB135/MC10,boiler,72,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp -GB125/GB135/MC10,boiler,72,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp -GB125/GB135/MC10,boiler,72,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow -GB125/GB135/MC10,boiler,72,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus -GB125/GB135/MC10,boiler,72,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff -GB125/GB135/MC10,boiler,72,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle -GB125/GB135/MC10,boiler,72,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp -GB125/GB135/MC10,boiler,72,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype -GB125/GB135/MC10,boiler,72,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort -GB125/GB135/MC10,boiler,72,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 -GB125/GB135/MC10,boiler,72,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset -GB125/GB135/MC10,boiler,72,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization -GB125/GB135/MC10,boiler,72,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -GB125/GB135/MC10,boiler,72,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp -GB125/GB135/MC10,boiler,72,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump -GB125/GB135/MC10,boiler,72,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype -GB125/GB135/MC10,boiler,72,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston -GB125/GB135/MC10,boiler,72,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -GB125/GB135/MC10,boiler,72,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp -GB125/GB135/MC10,boiler,72,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode -GB125/GB135/MC10,boiler,72,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc -GB125/GB135/MC10,boiler,72,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp -GB125/GB135/MC10,boiler,72,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 -GB125/GB135/MC10,boiler,72,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow -GB125/GB135/MC10,boiler,72,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 -GB125/GB135/MC10,boiler,72,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 -GB125/GB135/MC10,boiler,72,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated -GB125/GB135/MC10,boiler,72,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime -GB125/GB135/MC10,boiler,72,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting -GB125/GB135/MC10,boiler,72,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging -GB125/GB135/MC10,boiler,72,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging -GB125/GB135/MC10,boiler,72,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok -GB125/GB135/MC10,boiler,72,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive -GB125/GB135/MC10,boiler,72,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve -GB125/GB135/MC10,boiler,72,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower -GB125/GB135/MC10,boiler,72,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp -GB125/GB135/MC10,boiler,72,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -GB125/GB135/MC10,boiler,72,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -GB125/GB135/MC10,boiler,72,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -GB125/GB135/MC10,boiler,72,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower -GB125/GB135/MC10,boiler,72,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal -GB125/GB135/MC10,boiler,72,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -GB125/GB135/MC10,boiler,72,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww -Cascade CM10,boiler,81,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +GB125/GB135/MC10,boiler,72,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp +GB125/GB135/MC10,boiler,72,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat +GB125/GB135/MC10,boiler,72,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +GB125/GB135/MC10,boiler,72,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat +GB125/GB135/MC10,boiler,72,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +GB125/GB135/MC10,boiler,72,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 +GB125/GB135/MC10,boiler,72,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +GB125/GB135/MC10,boiler,72,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated +GB125/GB135/MC10,boiler,72,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp +GB125/GB135/MC10,boiler,72,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp +GB125/GB135/MC10,boiler,72,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow +GB125/GB135/MC10,boiler,72,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus +GB125/GB135/MC10,boiler,72,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff +GB125/GB135/MC10,boiler,72,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle +GB125/GB135/MC10,boiler,72,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp +GB125/GB135/MC10,boiler,72,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type +GB125/GB135/MC10,boiler,72,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort +GB125/GB135/MC10,boiler,72,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1 +GB125/GB135/MC10,boiler,72,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset +GB125/GB135/MC10,boiler,72,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization +GB125/GB135/MC10,boiler,72,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower +GB125/GB135/MC10,boiler,72,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp +GB125/GB135/MC10,boiler,72,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump +GB125/GB135/MC10,boiler,72,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype +GB125/GB135/MC10,boiler,72,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston +GB125/GB135/MC10,boiler,72,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff +GB125/GB135/MC10,boiler,72,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp +GB125/GB135/MC10,boiler,72,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode +GB125/GB135/MC10,boiler,72,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ +GB125/GB135/MC10,boiler,72,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp +GB125/GB135/MC10,boiler,72,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2 +GB125/GB135/MC10,boiler,72,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow +GB125/GB135/MC10,boiler,72,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1 +GB125/GB135/MC10,boiler,72,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2 +GB125/GB135/MC10,boiler,72,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated +GB125/GB135/MC10,boiler,72,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime +GB125/GB135/MC10,boiler,72,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting +GB125/GB135/MC10,boiler,72,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging +GB125/GB135/MC10,boiler,72,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging +GB125/GB135/MC10,boiler,72,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok +GB125/GB135/MC10,boiler,72,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active +GB125/GB135/MC10,boiler,72,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve +GB125/GB135/MC10,boiler,72,setpumppower,set pump power,uint8 (>=0<=100),%,false,sensor.boiler_dhw_set_pump_power,sensor.boiler_dhw_setpumppower +GB125/GB135/MC10,boiler,72,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp +GB125/GB135/MC10,boiler,72,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp +GB125/GB135/MC10,boiler,72,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts +GB125/GB135/MC10,boiler,72,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm +GB125/GB135/MC10,boiler,72,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +GB125/GB135/MC10,boiler,72,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +GB125/GB135/MC10,boiler,72,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +GB125/GB135/MC10,boiler,72,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Cascade CM10,boiler,81,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Cascade CM10,boiler,81,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Cascade CM10,boiler,81,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Cascade CM10,boiler,81,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Cascade CM10,boiler,81,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp -Cascade CM10,boiler,81,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod -Cascade CM10,boiler,81,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp -Cascade CM10,boiler,81,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp -Cascade CM10,boiler,81,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp -Cascade CM10,boiler,81,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp -Cascade CM10,boiler,81,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress -Cascade CM10,boiler,81,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp -Cascade CM10,boiler,81,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp -Cascade CM10,boiler,81,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp +Cascade CM10,boiler,81,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Cascade CM10,boiler,81,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod +Cascade CM10,boiler,81,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp +Cascade CM10,boiler,81,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp +Cascade CM10,boiler,81,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp +Cascade CM10,boiler,81,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp +Cascade CM10,boiler,81,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress +Cascade CM10,boiler,81,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Cascade CM10,boiler,81,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp +Cascade CM10,boiler,81,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Cascade CM10,boiler,81,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Cascade CM10,boiler,81,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 -Cascade CM10,boiler,81,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr +Cascade CM10,boiler,81,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Cascade CM10,boiler,81,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Cascade CM10,boiler,81,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Cascade CM10,boiler,81,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat -Cascade CM10,boiler,81,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Cascade CM10,boiler,81,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Cascade CM10,boiler,81,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Cascade CM10,boiler,81,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow -Cascade CM10,boiler,81,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock -Cascade CM10,boiler,81,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Cascade CM10,boiler,81,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Cascade CM10,boiler,81,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Cascade CM10,boiler,81,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Cascade CM10,boiler,81,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Cascade CM10,boiler,81,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Cascade CM10,boiler,81,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Cascade CM10,boiler,81,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Cascade CM10,boiler,81,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Cascade CM10,boiler,81,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Cascade CM10,boiler,81,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff +Cascade CM10,boiler,81,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston +Cascade CM10,boiler,81,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Cascade CM10,boiler,81,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon -Cascade CM10,boiler,81,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase -Cascade CM10,boiler,81,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Cascade CM10,boiler,81,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Cascade CM10,boiler,81,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase +Cascade CM10,boiler,81,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend +Cascade CM10,boiler,81,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Cascade CM10,boiler,81,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode -Cascade CM10,boiler,81,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp +Cascade CM10,boiler,81,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Cascade CM10,boiler,81,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Cascade CM10,boiler,81,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Cascade CM10,boiler,81,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Cascade CM10,boiler,81,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump -Cascade CM10,boiler,81,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax -Cascade CM10,boiler,81,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin +Cascade CM10,boiler,81,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax +Cascade CM10,boiler,81,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Cascade CM10,boiler,81,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Cascade CM10,boiler,81,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Cascade CM10,boiler,81,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp -Cascade CM10,boiler,81,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Cascade CM10,boiler,81,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow -Cascade CM10,boiler,81,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Cascade CM10,boiler,81,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Cascade CM10,boiler,81,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay +Cascade CM10,boiler,81,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp +Cascade CM10,boiler,81,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow +Cascade CM10,boiler,81,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow +Cascade CM10,boiler,81,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow +Cascade CM10,boiler,81,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Cascade CM10,boiler,81,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Cascade CM10,boiler,81,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Cascade CM10,boiler,81,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Cascade CM10,boiler,81,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Cascade CM10,boiler,81,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Cascade CM10,boiler,81,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Cascade CM10,boiler,81,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Cascade CM10,boiler,81,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode -Cascade CM10,boiler,81,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber +Cascade CM10,boiler,81,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Cascade CM10,boiler,81,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Cascade CM10,boiler,81,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance -Cascade CM10,boiler,81,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime +Cascade CM10,boiler,81,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Cascade CM10,boiler,81,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Cascade CM10,boiler,81,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops -Cascade CM10,boiler,81,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp -Cascade CM10,boiler,81,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated -Cascade CM10,boiler,81,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp -Cascade CM10,boiler,81,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp -Cascade CM10,boiler,81,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow -Cascade CM10,boiler,81,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus -Cascade CM10,boiler,81,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff -Cascade CM10,boiler,81,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle -Cascade CM10,boiler,81,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp -Cascade CM10,boiler,81,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype -Cascade CM10,boiler,81,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort -Cascade CM10,boiler,81,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 -Cascade CM10,boiler,81,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset -Cascade CM10,boiler,81,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization -Cascade CM10,boiler,81,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Cascade CM10,boiler,81,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp -Cascade CM10,boiler,81,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump -Cascade CM10,boiler,81,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype -Cascade CM10,boiler,81,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston -Cascade CM10,boiler,81,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Cascade CM10,boiler,81,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp -Cascade CM10,boiler,81,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode -Cascade CM10,boiler,81,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc -Cascade CM10,boiler,81,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp -Cascade CM10,boiler,81,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 -Cascade CM10,boiler,81,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow -Cascade CM10,boiler,81,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 -Cascade CM10,boiler,81,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 -Cascade CM10,boiler,81,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated -Cascade CM10,boiler,81,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime -Cascade CM10,boiler,81,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting -Cascade CM10,boiler,81,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging -Cascade CM10,boiler,81,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging -Cascade CM10,boiler,81,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok -Cascade CM10,boiler,81,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive -Cascade CM10,boiler,81,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve -Cascade CM10,boiler,81,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower -Cascade CM10,boiler,81,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp -Cascade CM10,boiler,81,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Cascade CM10,boiler,81,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Cascade CM10,boiler,81,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Cascade CM10,boiler,81,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower -Cascade CM10,boiler,81,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal -Cascade CM10,boiler,81,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Cascade CM10,boiler,81,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww -Logamax Plus GB022,boiler,84,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Cascade CM10,boiler,81,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp +Cascade CM10,boiler,81,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat +Cascade CM10,boiler,81,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Cascade CM10,boiler,81,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat +Cascade CM10,boiler,81,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Cascade CM10,boiler,81,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 +Cascade CM10,boiler,81,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Cascade CM10,boiler,81,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated +Cascade CM10,boiler,81,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp +Cascade CM10,boiler,81,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp +Cascade CM10,boiler,81,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow +Cascade CM10,boiler,81,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus +Cascade CM10,boiler,81,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff +Cascade CM10,boiler,81,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle +Cascade CM10,boiler,81,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp +Cascade CM10,boiler,81,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type +Cascade CM10,boiler,81,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort +Cascade CM10,boiler,81,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1 +Cascade CM10,boiler,81,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset +Cascade CM10,boiler,81,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization +Cascade CM10,boiler,81,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower +Cascade CM10,boiler,81,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp +Cascade CM10,boiler,81,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump +Cascade CM10,boiler,81,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype +Cascade CM10,boiler,81,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston +Cascade CM10,boiler,81,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff +Cascade CM10,boiler,81,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp +Cascade CM10,boiler,81,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode +Cascade CM10,boiler,81,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ +Cascade CM10,boiler,81,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp +Cascade CM10,boiler,81,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2 +Cascade CM10,boiler,81,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow +Cascade CM10,boiler,81,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1 +Cascade CM10,boiler,81,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2 +Cascade CM10,boiler,81,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated +Cascade CM10,boiler,81,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime +Cascade CM10,boiler,81,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting +Cascade CM10,boiler,81,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging +Cascade CM10,boiler,81,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging +Cascade CM10,boiler,81,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok +Cascade CM10,boiler,81,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active +Cascade CM10,boiler,81,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve +Cascade CM10,boiler,81,setpumppower,set pump power,uint8 (>=0<=100),%,false,sensor.boiler_dhw_set_pump_power,sensor.boiler_dhw_setpumppower +Cascade CM10,boiler,81,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp +Cascade CM10,boiler,81,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp +Cascade CM10,boiler,81,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts +Cascade CM10,boiler,81,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm +Cascade CM10,boiler,81,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Cascade CM10,boiler,81,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Cascade CM10,boiler,81,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Cascade CM10,boiler,81,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Logamax Plus GB022,boiler,84,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Logamax Plus GB022,boiler,84,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Logamax Plus GB022,boiler,84,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Logamax Plus GB022,boiler,84,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Logamax Plus GB022,boiler,84,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp -Logamax Plus GB022,boiler,84,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod -Logamax Plus GB022,boiler,84,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp -Logamax Plus GB022,boiler,84,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp -Logamax Plus GB022,boiler,84,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp -Logamax Plus GB022,boiler,84,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp -Logamax Plus GB022,boiler,84,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress -Logamax Plus GB022,boiler,84,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp -Logamax Plus GB022,boiler,84,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp -Logamax Plus GB022,boiler,84,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp +Logamax Plus GB022,boiler,84,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Logamax Plus GB022,boiler,84,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod +Logamax Plus GB022,boiler,84,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp +Logamax Plus GB022,boiler,84,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp +Logamax Plus GB022,boiler,84,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp +Logamax Plus GB022,boiler,84,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp +Logamax Plus GB022,boiler,84,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress +Logamax Plus GB022,boiler,84,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Logamax Plus GB022,boiler,84,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp +Logamax Plus GB022,boiler,84,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Logamax Plus GB022,boiler,84,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Logamax Plus GB022,boiler,84,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 -Logamax Plus GB022,boiler,84,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr +Logamax Plus GB022,boiler,84,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Logamax Plus GB022,boiler,84,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Logamax Plus GB022,boiler,84,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Logamax Plus GB022,boiler,84,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat -Logamax Plus GB022,boiler,84,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Logamax Plus GB022,boiler,84,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Logamax Plus GB022,boiler,84,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Logamax Plus GB022,boiler,84,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow -Logamax Plus GB022,boiler,84,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock -Logamax Plus GB022,boiler,84,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Logamax Plus GB022,boiler,84,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Logamax Plus GB022,boiler,84,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Logamax Plus GB022,boiler,84,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Logamax Plus GB022,boiler,84,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Logamax Plus GB022,boiler,84,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Logamax Plus GB022,boiler,84,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Logamax Plus GB022,boiler,84,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Logamax Plus GB022,boiler,84,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Logamax Plus GB022,boiler,84,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Logamax Plus GB022,boiler,84,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff +Logamax Plus GB022,boiler,84,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston +Logamax Plus GB022,boiler,84,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Logamax Plus GB022,boiler,84,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon -Logamax Plus GB022,boiler,84,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase -Logamax Plus GB022,boiler,84,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Logamax Plus GB022,boiler,84,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Logamax Plus GB022,boiler,84,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase +Logamax Plus GB022,boiler,84,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend +Logamax Plus GB022,boiler,84,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Logamax Plus GB022,boiler,84,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode -Logamax Plus GB022,boiler,84,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp +Logamax Plus GB022,boiler,84,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Logamax Plus GB022,boiler,84,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Logamax Plus GB022,boiler,84,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Logamax Plus GB022,boiler,84,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Logamax Plus GB022,boiler,84,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump -Logamax Plus GB022,boiler,84,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax -Logamax Plus GB022,boiler,84,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin +Logamax Plus GB022,boiler,84,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax +Logamax Plus GB022,boiler,84,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Logamax Plus GB022,boiler,84,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Logamax Plus GB022,boiler,84,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Logamax Plus GB022,boiler,84,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp -Logamax Plus GB022,boiler,84,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Logamax Plus GB022,boiler,84,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow -Logamax Plus GB022,boiler,84,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Logamax Plus GB022,boiler,84,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Logamax Plus GB022,boiler,84,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay +Logamax Plus GB022,boiler,84,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp +Logamax Plus GB022,boiler,84,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow +Logamax Plus GB022,boiler,84,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow +Logamax Plus GB022,boiler,84,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow +Logamax Plus GB022,boiler,84,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Logamax Plus GB022,boiler,84,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Logamax Plus GB022,boiler,84,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Logamax Plus GB022,boiler,84,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Logamax Plus GB022,boiler,84,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Logamax Plus GB022,boiler,84,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Logamax Plus GB022,boiler,84,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Logamax Plus GB022,boiler,84,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Logamax Plus GB022,boiler,84,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode -Logamax Plus GB022,boiler,84,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber +Logamax Plus GB022,boiler,84,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Logamax Plus GB022,boiler,84,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Logamax Plus GB022,boiler,84,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance -Logamax Plus GB022,boiler,84,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime +Logamax Plus GB022,boiler,84,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Logamax Plus GB022,boiler,84,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Logamax Plus GB022,boiler,84,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops -Logamax Plus GB022,boiler,84,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp -Logamax Plus GB022,boiler,84,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated -Logamax Plus GB022,boiler,84,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp -Logamax Plus GB022,boiler,84,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp -Logamax Plus GB022,boiler,84,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow -Logamax Plus GB022,boiler,84,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus -Logamax Plus GB022,boiler,84,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff -Logamax Plus GB022,boiler,84,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle -Logamax Plus GB022,boiler,84,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp -Logamax Plus GB022,boiler,84,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype -Logamax Plus GB022,boiler,84,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort -Logamax Plus GB022,boiler,84,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 -Logamax Plus GB022,boiler,84,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset -Logamax Plus GB022,boiler,84,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization -Logamax Plus GB022,boiler,84,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Logamax Plus GB022,boiler,84,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp -Logamax Plus GB022,boiler,84,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump -Logamax Plus GB022,boiler,84,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype -Logamax Plus GB022,boiler,84,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston -Logamax Plus GB022,boiler,84,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Logamax Plus GB022,boiler,84,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp -Logamax Plus GB022,boiler,84,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode -Logamax Plus GB022,boiler,84,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc -Logamax Plus GB022,boiler,84,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp -Logamax Plus GB022,boiler,84,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 -Logamax Plus GB022,boiler,84,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow -Logamax Plus GB022,boiler,84,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 -Logamax Plus GB022,boiler,84,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 -Logamax Plus GB022,boiler,84,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated -Logamax Plus GB022,boiler,84,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime -Logamax Plus GB022,boiler,84,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting -Logamax Plus GB022,boiler,84,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging -Logamax Plus GB022,boiler,84,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging -Logamax Plus GB022,boiler,84,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok -Logamax Plus GB022,boiler,84,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive -Logamax Plus GB022,boiler,84,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve -Logamax Plus GB022,boiler,84,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower -Logamax Plus GB022,boiler,84,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp -Logamax Plus GB022,boiler,84,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Logamax Plus GB022,boiler,84,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Logamax Plus GB022,boiler,84,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Logamax Plus GB022,boiler,84,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower -Logamax Plus GB022,boiler,84,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal -Logamax Plus GB022,boiler,84,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Logamax Plus GB022,boiler,84,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Logamax Plus GB022,boiler,84,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp +Logamax Plus GB022,boiler,84,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat +Logamax Plus GB022,boiler,84,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Logamax Plus GB022,boiler,84,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat +Logamax Plus GB022,boiler,84,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Logamax Plus GB022,boiler,84,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 +Logamax Plus GB022,boiler,84,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Logamax Plus GB022,boiler,84,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated +Logamax Plus GB022,boiler,84,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp +Logamax Plus GB022,boiler,84,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp +Logamax Plus GB022,boiler,84,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow +Logamax Plus GB022,boiler,84,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus +Logamax Plus GB022,boiler,84,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff +Logamax Plus GB022,boiler,84,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle +Logamax Plus GB022,boiler,84,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp +Logamax Plus GB022,boiler,84,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type +Logamax Plus GB022,boiler,84,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort +Logamax Plus GB022,boiler,84,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1 +Logamax Plus GB022,boiler,84,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset +Logamax Plus GB022,boiler,84,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization +Logamax Plus GB022,boiler,84,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower +Logamax Plus GB022,boiler,84,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp +Logamax Plus GB022,boiler,84,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump +Logamax Plus GB022,boiler,84,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype +Logamax Plus GB022,boiler,84,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston +Logamax Plus GB022,boiler,84,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff +Logamax Plus GB022,boiler,84,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp +Logamax Plus GB022,boiler,84,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode +Logamax Plus GB022,boiler,84,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ +Logamax Plus GB022,boiler,84,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp +Logamax Plus GB022,boiler,84,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2 +Logamax Plus GB022,boiler,84,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow +Logamax Plus GB022,boiler,84,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1 +Logamax Plus GB022,boiler,84,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2 +Logamax Plus GB022,boiler,84,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated +Logamax Plus GB022,boiler,84,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime +Logamax Plus GB022,boiler,84,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting +Logamax Plus GB022,boiler,84,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging +Logamax Plus GB022,boiler,84,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging +Logamax Plus GB022,boiler,84,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok +Logamax Plus GB022,boiler,84,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active +Logamax Plus GB022,boiler,84,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve +Logamax Plus GB022,boiler,84,setpumppower,set pump power,uint8 (>=0<=100),%,false,sensor.boiler_dhw_set_pump_power,sensor.boiler_dhw_setpumppower +Logamax Plus GB022,boiler,84,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp +Logamax Plus GB022,boiler,84,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp +Logamax Plus GB022,boiler,84,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts +Logamax Plus GB022,boiler,84,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm +Logamax Plus GB022,boiler,84,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Logamax Plus GB022,boiler,84,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Logamax Plus GB022,boiler,84,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Logamax Plus GB022,boiler,84,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww -Topline/GB162,boiler,115,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1 +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2 +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1 +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2 +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,setpumppower,set pump power,uint8 (>=0<=100),%,false,sensor.boiler_dhw_set_pump_power,sensor.boiler_dhw_setpumppower +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Topline/GB162,boiler,115,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Topline/GB162,boiler,115,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Topline/GB162,boiler,115,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Topline/GB162,boiler,115,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Topline/GB162,boiler,115,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp -Topline/GB162,boiler,115,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod -Topline/GB162,boiler,115,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp -Topline/GB162,boiler,115,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp -Topline/GB162,boiler,115,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp -Topline/GB162,boiler,115,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp -Topline/GB162,boiler,115,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress -Topline/GB162,boiler,115,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp -Topline/GB162,boiler,115,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp -Topline/GB162,boiler,115,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp +Topline/GB162,boiler,115,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Topline/GB162,boiler,115,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod +Topline/GB162,boiler,115,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp +Topline/GB162,boiler,115,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp +Topline/GB162,boiler,115,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp +Topline/GB162,boiler,115,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp +Topline/GB162,boiler,115,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress +Topline/GB162,boiler,115,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Topline/GB162,boiler,115,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp +Topline/GB162,boiler,115,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Topline/GB162,boiler,115,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Topline/GB162,boiler,115,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 -Topline/GB162,boiler,115,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr +Topline/GB162,boiler,115,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Topline/GB162,boiler,115,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Topline/GB162,boiler,115,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Topline/GB162,boiler,115,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat -Topline/GB162,boiler,115,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Topline/GB162,boiler,115,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Topline/GB162,boiler,115,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Topline/GB162,boiler,115,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow -Topline/GB162,boiler,115,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock -Topline/GB162,boiler,115,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Topline/GB162,boiler,115,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Topline/GB162,boiler,115,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Topline/GB162,boiler,115,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Topline/GB162,boiler,115,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Topline/GB162,boiler,115,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Topline/GB162,boiler,115,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Topline/GB162,boiler,115,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Topline/GB162,boiler,115,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Topline/GB162,boiler,115,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Topline/GB162,boiler,115,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff +Topline/GB162,boiler,115,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston +Topline/GB162,boiler,115,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Topline/GB162,boiler,115,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon -Topline/GB162,boiler,115,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase -Topline/GB162,boiler,115,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Topline/GB162,boiler,115,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Topline/GB162,boiler,115,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase +Topline/GB162,boiler,115,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend +Topline/GB162,boiler,115,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Topline/GB162,boiler,115,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode -Topline/GB162,boiler,115,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp +Topline/GB162,boiler,115,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Topline/GB162,boiler,115,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Topline/GB162,boiler,115,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Topline/GB162,boiler,115,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Topline/GB162,boiler,115,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump -Topline/GB162,boiler,115,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax -Topline/GB162,boiler,115,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin +Topline/GB162,boiler,115,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax +Topline/GB162,boiler,115,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Topline/GB162,boiler,115,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Topline/GB162,boiler,115,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Topline/GB162,boiler,115,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp -Topline/GB162,boiler,115,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Topline/GB162,boiler,115,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow -Topline/GB162,boiler,115,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Topline/GB162,boiler,115,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Topline/GB162,boiler,115,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay +Topline/GB162,boiler,115,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp +Topline/GB162,boiler,115,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow +Topline/GB162,boiler,115,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow +Topline/GB162,boiler,115,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow +Topline/GB162,boiler,115,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Topline/GB162,boiler,115,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Topline/GB162,boiler,115,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Topline/GB162,boiler,115,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Topline/GB162,boiler,115,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Topline/GB162,boiler,115,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Topline/GB162,boiler,115,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Topline/GB162,boiler,115,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Topline/GB162,boiler,115,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode -Topline/GB162,boiler,115,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber +Topline/GB162,boiler,115,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Topline/GB162,boiler,115,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Topline/GB162,boiler,115,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance -Topline/GB162,boiler,115,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime +Topline/GB162,boiler,115,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Topline/GB162,boiler,115,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Topline/GB162,boiler,115,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops -Topline/GB162,boiler,115,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp -Topline/GB162,boiler,115,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated -Topline/GB162,boiler,115,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp -Topline/GB162,boiler,115,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp -Topline/GB162,boiler,115,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow -Topline/GB162,boiler,115,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus -Topline/GB162,boiler,115,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff -Topline/GB162,boiler,115,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle -Topline/GB162,boiler,115,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp -Topline/GB162,boiler,115,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype -Topline/GB162,boiler,115,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort -Topline/GB162,boiler,115,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 -Topline/GB162,boiler,115,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset -Topline/GB162,boiler,115,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization -Topline/GB162,boiler,115,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Topline/GB162,boiler,115,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp -Topline/GB162,boiler,115,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump -Topline/GB162,boiler,115,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype -Topline/GB162,boiler,115,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston -Topline/GB162,boiler,115,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Topline/GB162,boiler,115,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp -Topline/GB162,boiler,115,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode -Topline/GB162,boiler,115,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc -Topline/GB162,boiler,115,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp -Topline/GB162,boiler,115,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 -Topline/GB162,boiler,115,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow -Topline/GB162,boiler,115,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 -Topline/GB162,boiler,115,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 -Topline/GB162,boiler,115,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated -Topline/GB162,boiler,115,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime -Topline/GB162,boiler,115,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting -Topline/GB162,boiler,115,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging -Topline/GB162,boiler,115,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging -Topline/GB162,boiler,115,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok -Topline/GB162,boiler,115,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive -Topline/GB162,boiler,115,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve -Topline/GB162,boiler,115,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower -Topline/GB162,boiler,115,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp -Topline/GB162,boiler,115,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Topline/GB162,boiler,115,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Topline/GB162,boiler,115,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Topline/GB162,boiler,115,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower -Topline/GB162,boiler,115,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal -Topline/GB162,boiler,115,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Topline/GB162,boiler,115,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww -Cascade MCM10,boiler,121,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Topline/GB162,boiler,115,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp +Topline/GB162,boiler,115,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat +Topline/GB162,boiler,115,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Topline/GB162,boiler,115,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat +Topline/GB162,boiler,115,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Topline/GB162,boiler,115,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 +Topline/GB162,boiler,115,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Topline/GB162,boiler,115,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated +Topline/GB162,boiler,115,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp +Topline/GB162,boiler,115,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp +Topline/GB162,boiler,115,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow +Topline/GB162,boiler,115,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus +Topline/GB162,boiler,115,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff +Topline/GB162,boiler,115,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle +Topline/GB162,boiler,115,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp +Topline/GB162,boiler,115,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type +Topline/GB162,boiler,115,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort +Topline/GB162,boiler,115,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1 +Topline/GB162,boiler,115,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset +Topline/GB162,boiler,115,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization +Topline/GB162,boiler,115,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower +Topline/GB162,boiler,115,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp +Topline/GB162,boiler,115,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump +Topline/GB162,boiler,115,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype +Topline/GB162,boiler,115,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston +Topline/GB162,boiler,115,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff +Topline/GB162,boiler,115,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp +Topline/GB162,boiler,115,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode +Topline/GB162,boiler,115,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ +Topline/GB162,boiler,115,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp +Topline/GB162,boiler,115,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2 +Topline/GB162,boiler,115,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow +Topline/GB162,boiler,115,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1 +Topline/GB162,boiler,115,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2 +Topline/GB162,boiler,115,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated +Topline/GB162,boiler,115,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime +Topline/GB162,boiler,115,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting +Topline/GB162,boiler,115,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging +Topline/GB162,boiler,115,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging +Topline/GB162,boiler,115,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok +Topline/GB162,boiler,115,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active +Topline/GB162,boiler,115,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve +Topline/GB162,boiler,115,setpumppower,set pump power,uint8 (>=0<=100),%,false,sensor.boiler_dhw_set_pump_power,sensor.boiler_dhw_setpumppower +Topline/GB162,boiler,115,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp +Topline/GB162,boiler,115,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp +Topline/GB162,boiler,115,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts +Topline/GB162,boiler,115,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm +Topline/GB162,boiler,115,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Topline/GB162,boiler,115,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Topline/GB162,boiler,115,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Topline/GB162,boiler,115,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Cascade MCM10,boiler,121,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Cascade MCM10,boiler,121,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Cascade MCM10,boiler,121,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Cascade MCM10,boiler,121,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Cascade MCM10,boiler,121,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp -Cascade MCM10,boiler,121,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod -Cascade MCM10,boiler,121,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp -Cascade MCM10,boiler,121,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp -Cascade MCM10,boiler,121,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp -Cascade MCM10,boiler,121,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp -Cascade MCM10,boiler,121,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress -Cascade MCM10,boiler,121,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp -Cascade MCM10,boiler,121,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp -Cascade MCM10,boiler,121,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp +Cascade MCM10,boiler,121,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Cascade MCM10,boiler,121,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod +Cascade MCM10,boiler,121,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp +Cascade MCM10,boiler,121,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp +Cascade MCM10,boiler,121,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp +Cascade MCM10,boiler,121,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp +Cascade MCM10,boiler,121,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress +Cascade MCM10,boiler,121,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Cascade MCM10,boiler,121,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp +Cascade MCM10,boiler,121,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Cascade MCM10,boiler,121,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Cascade MCM10,boiler,121,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 -Cascade MCM10,boiler,121,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr +Cascade MCM10,boiler,121,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Cascade MCM10,boiler,121,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Cascade MCM10,boiler,121,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Cascade MCM10,boiler,121,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat -Cascade MCM10,boiler,121,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Cascade MCM10,boiler,121,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Cascade MCM10,boiler,121,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Cascade MCM10,boiler,121,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow -Cascade MCM10,boiler,121,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock -Cascade MCM10,boiler,121,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Cascade MCM10,boiler,121,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Cascade MCM10,boiler,121,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Cascade MCM10,boiler,121,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Cascade MCM10,boiler,121,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Cascade MCM10,boiler,121,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Cascade MCM10,boiler,121,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Cascade MCM10,boiler,121,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Cascade MCM10,boiler,121,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Cascade MCM10,boiler,121,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Cascade MCM10,boiler,121,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff +Cascade MCM10,boiler,121,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston +Cascade MCM10,boiler,121,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Cascade MCM10,boiler,121,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon -Cascade MCM10,boiler,121,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase -Cascade MCM10,boiler,121,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Cascade MCM10,boiler,121,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Cascade MCM10,boiler,121,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase +Cascade MCM10,boiler,121,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend +Cascade MCM10,boiler,121,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Cascade MCM10,boiler,121,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode -Cascade MCM10,boiler,121,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp +Cascade MCM10,boiler,121,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Cascade MCM10,boiler,121,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Cascade MCM10,boiler,121,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Cascade MCM10,boiler,121,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Cascade MCM10,boiler,121,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump -Cascade MCM10,boiler,121,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax -Cascade MCM10,boiler,121,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin +Cascade MCM10,boiler,121,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax +Cascade MCM10,boiler,121,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Cascade MCM10,boiler,121,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Cascade MCM10,boiler,121,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Cascade MCM10,boiler,121,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp -Cascade MCM10,boiler,121,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Cascade MCM10,boiler,121,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow -Cascade MCM10,boiler,121,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Cascade MCM10,boiler,121,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Cascade MCM10,boiler,121,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay +Cascade MCM10,boiler,121,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp +Cascade MCM10,boiler,121,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow +Cascade MCM10,boiler,121,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow +Cascade MCM10,boiler,121,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow +Cascade MCM10,boiler,121,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Cascade MCM10,boiler,121,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Cascade MCM10,boiler,121,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Cascade MCM10,boiler,121,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Cascade MCM10,boiler,121,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Cascade MCM10,boiler,121,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Cascade MCM10,boiler,121,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Cascade MCM10,boiler,121,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Cascade MCM10,boiler,121,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode -Cascade MCM10,boiler,121,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber +Cascade MCM10,boiler,121,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Cascade MCM10,boiler,121,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Cascade MCM10,boiler,121,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance -Cascade MCM10,boiler,121,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime +Cascade MCM10,boiler,121,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Cascade MCM10,boiler,121,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Cascade MCM10,boiler,121,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops -Cascade MCM10,boiler,121,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp -Cascade MCM10,boiler,121,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated -Cascade MCM10,boiler,121,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp -Cascade MCM10,boiler,121,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp -Cascade MCM10,boiler,121,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow -Cascade MCM10,boiler,121,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus -Cascade MCM10,boiler,121,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff -Cascade MCM10,boiler,121,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle -Cascade MCM10,boiler,121,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp -Cascade MCM10,boiler,121,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype -Cascade MCM10,boiler,121,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort -Cascade MCM10,boiler,121,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 -Cascade MCM10,boiler,121,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset -Cascade MCM10,boiler,121,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization -Cascade MCM10,boiler,121,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Cascade MCM10,boiler,121,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp -Cascade MCM10,boiler,121,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump -Cascade MCM10,boiler,121,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype -Cascade MCM10,boiler,121,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston -Cascade MCM10,boiler,121,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Cascade MCM10,boiler,121,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp -Cascade MCM10,boiler,121,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode -Cascade MCM10,boiler,121,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc -Cascade MCM10,boiler,121,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp -Cascade MCM10,boiler,121,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 -Cascade MCM10,boiler,121,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow -Cascade MCM10,boiler,121,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 -Cascade MCM10,boiler,121,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 -Cascade MCM10,boiler,121,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated -Cascade MCM10,boiler,121,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime -Cascade MCM10,boiler,121,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting -Cascade MCM10,boiler,121,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging -Cascade MCM10,boiler,121,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging -Cascade MCM10,boiler,121,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok -Cascade MCM10,boiler,121,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive -Cascade MCM10,boiler,121,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve -Cascade MCM10,boiler,121,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower -Cascade MCM10,boiler,121,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp -Cascade MCM10,boiler,121,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Cascade MCM10,boiler,121,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Cascade MCM10,boiler,121,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Cascade MCM10,boiler,121,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower -Cascade MCM10,boiler,121,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal -Cascade MCM10,boiler,121,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Cascade MCM10,boiler,121,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww -Proline,boiler,122,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Cascade MCM10,boiler,121,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp +Cascade MCM10,boiler,121,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat +Cascade MCM10,boiler,121,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Cascade MCM10,boiler,121,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat +Cascade MCM10,boiler,121,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Cascade MCM10,boiler,121,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 +Cascade MCM10,boiler,121,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Cascade MCM10,boiler,121,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated +Cascade MCM10,boiler,121,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp +Cascade MCM10,boiler,121,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp +Cascade MCM10,boiler,121,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow +Cascade MCM10,boiler,121,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus +Cascade MCM10,boiler,121,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff +Cascade MCM10,boiler,121,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle +Cascade MCM10,boiler,121,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp +Cascade MCM10,boiler,121,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type +Cascade MCM10,boiler,121,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort +Cascade MCM10,boiler,121,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1 +Cascade MCM10,boiler,121,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset +Cascade MCM10,boiler,121,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization +Cascade MCM10,boiler,121,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower +Cascade MCM10,boiler,121,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp +Cascade MCM10,boiler,121,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump +Cascade MCM10,boiler,121,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype +Cascade MCM10,boiler,121,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston +Cascade MCM10,boiler,121,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff +Cascade MCM10,boiler,121,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp +Cascade MCM10,boiler,121,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode +Cascade MCM10,boiler,121,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ +Cascade MCM10,boiler,121,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp +Cascade MCM10,boiler,121,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2 +Cascade MCM10,boiler,121,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow +Cascade MCM10,boiler,121,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1 +Cascade MCM10,boiler,121,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2 +Cascade MCM10,boiler,121,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated +Cascade MCM10,boiler,121,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime +Cascade MCM10,boiler,121,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting +Cascade MCM10,boiler,121,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging +Cascade MCM10,boiler,121,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging +Cascade MCM10,boiler,121,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok +Cascade MCM10,boiler,121,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active +Cascade MCM10,boiler,121,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve +Cascade MCM10,boiler,121,setpumppower,set pump power,uint8 (>=0<=100),%,false,sensor.boiler_dhw_set_pump_power,sensor.boiler_dhw_setpumppower +Cascade MCM10,boiler,121,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp +Cascade MCM10,boiler,121,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp +Cascade MCM10,boiler,121,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts +Cascade MCM10,boiler,121,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm +Cascade MCM10,boiler,121,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Cascade MCM10,boiler,121,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Cascade MCM10,boiler,121,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Cascade MCM10,boiler,121,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Proline,boiler,122,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Proline,boiler,122,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Proline,boiler,122,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Proline,boiler,122,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Proline,boiler,122,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp -Proline,boiler,122,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod -Proline,boiler,122,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp -Proline,boiler,122,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp -Proline,boiler,122,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp -Proline,boiler,122,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp -Proline,boiler,122,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress -Proline,boiler,122,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp -Proline,boiler,122,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp -Proline,boiler,122,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp +Proline,boiler,122,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Proline,boiler,122,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod +Proline,boiler,122,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp +Proline,boiler,122,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp +Proline,boiler,122,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp +Proline,boiler,122,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp +Proline,boiler,122,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress +Proline,boiler,122,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Proline,boiler,122,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp +Proline,boiler,122,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Proline,boiler,122,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Proline,boiler,122,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 -Proline,boiler,122,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr +Proline,boiler,122,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Proline,boiler,122,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Proline,boiler,122,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Proline,boiler,122,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat -Proline,boiler,122,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Proline,boiler,122,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Proline,boiler,122,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Proline,boiler,122,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow -Proline,boiler,122,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock -Proline,boiler,122,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Proline,boiler,122,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Proline,boiler,122,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Proline,boiler,122,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Proline,boiler,122,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Proline,boiler,122,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Proline,boiler,122,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Proline,boiler,122,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Proline,boiler,122,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Proline,boiler,122,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Proline,boiler,122,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff +Proline,boiler,122,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston +Proline,boiler,122,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Proline,boiler,122,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon -Proline,boiler,122,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase -Proline,boiler,122,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Proline,boiler,122,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Proline,boiler,122,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase +Proline,boiler,122,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend +Proline,boiler,122,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Proline,boiler,122,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode -Proline,boiler,122,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp +Proline,boiler,122,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Proline,boiler,122,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Proline,boiler,122,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Proline,boiler,122,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Proline,boiler,122,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump -Proline,boiler,122,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax -Proline,boiler,122,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin +Proline,boiler,122,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax +Proline,boiler,122,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Proline,boiler,122,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Proline,boiler,122,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Proline,boiler,122,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp -Proline,boiler,122,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Proline,boiler,122,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow -Proline,boiler,122,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Proline,boiler,122,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Proline,boiler,122,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay +Proline,boiler,122,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp +Proline,boiler,122,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow +Proline,boiler,122,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow +Proline,boiler,122,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow +Proline,boiler,122,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Proline,boiler,122,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Proline,boiler,122,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Proline,boiler,122,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Proline,boiler,122,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Proline,boiler,122,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Proline,boiler,122,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Proline,boiler,122,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Proline,boiler,122,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode -Proline,boiler,122,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber +Proline,boiler,122,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Proline,boiler,122,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Proline,boiler,122,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance -Proline,boiler,122,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime +Proline,boiler,122,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Proline,boiler,122,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Proline,boiler,122,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops -Proline,boiler,122,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp -Proline,boiler,122,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated -Proline,boiler,122,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp -Proline,boiler,122,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp -Proline,boiler,122,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow -Proline,boiler,122,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus -Proline,boiler,122,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff -Proline,boiler,122,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle -Proline,boiler,122,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp -Proline,boiler,122,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype -Proline,boiler,122,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort -Proline,boiler,122,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 -Proline,boiler,122,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset -Proline,boiler,122,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization -Proline,boiler,122,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Proline,boiler,122,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp -Proline,boiler,122,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump -Proline,boiler,122,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype -Proline,boiler,122,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston -Proline,boiler,122,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Proline,boiler,122,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp -Proline,boiler,122,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode -Proline,boiler,122,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc -Proline,boiler,122,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp -Proline,boiler,122,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 -Proline,boiler,122,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow -Proline,boiler,122,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 -Proline,boiler,122,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 -Proline,boiler,122,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated -Proline,boiler,122,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime -Proline,boiler,122,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting -Proline,boiler,122,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging -Proline,boiler,122,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging -Proline,boiler,122,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok -Proline,boiler,122,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive -Proline,boiler,122,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve -Proline,boiler,122,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower -Proline,boiler,122,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp -Proline,boiler,122,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Proline,boiler,122,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Proline,boiler,122,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Proline,boiler,122,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower -Proline,boiler,122,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal -Proline,boiler,122,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Proline,boiler,122,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Proline,boiler,122,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp +Proline,boiler,122,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat +Proline,boiler,122,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Proline,boiler,122,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat +Proline,boiler,122,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Proline,boiler,122,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 +Proline,boiler,122,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Proline,boiler,122,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated +Proline,boiler,122,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp +Proline,boiler,122,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp +Proline,boiler,122,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow +Proline,boiler,122,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus +Proline,boiler,122,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff +Proline,boiler,122,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle +Proline,boiler,122,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp +Proline,boiler,122,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type +Proline,boiler,122,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort +Proline,boiler,122,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1 +Proline,boiler,122,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset +Proline,boiler,122,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization +Proline,boiler,122,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower +Proline,boiler,122,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp +Proline,boiler,122,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump +Proline,boiler,122,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype +Proline,boiler,122,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston +Proline,boiler,122,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff +Proline,boiler,122,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp +Proline,boiler,122,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode +Proline,boiler,122,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ +Proline,boiler,122,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp +Proline,boiler,122,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2 +Proline,boiler,122,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow +Proline,boiler,122,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1 +Proline,boiler,122,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2 +Proline,boiler,122,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated +Proline,boiler,122,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime +Proline,boiler,122,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting +Proline,boiler,122,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging +Proline,boiler,122,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging +Proline,boiler,122,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok +Proline,boiler,122,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active +Proline,boiler,122,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve +Proline,boiler,122,setpumppower,set pump power,uint8 (>=0<=100),%,false,sensor.boiler_dhw_set_pump_power,sensor.boiler_dhw_setpumppower +Proline,boiler,122,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp +Proline,boiler,122,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp +Proline,boiler,122,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts +Proline,boiler,122,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm +Proline,boiler,122,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Proline,boiler,122,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Proline,boiler,122,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Proline,boiler,122,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww -GB212,boiler,131,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1 +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2 +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1 +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2 +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,setpumppower,set pump power,uint8 (>=0<=100),%,false,sensor.boiler_dhw_set_pump_power,sensor.boiler_dhw_setpumppower +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +GB212,boiler,131,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset GB212,boiler,131,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff GB212,boiler,131,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive GB212,boiler,131,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -GB212,boiler,131,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp -GB212,boiler,131,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod -GB212,boiler,131,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp -GB212,boiler,131,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp -GB212,boiler,131,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp -GB212,boiler,131,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp -GB212,boiler,131,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress -GB212,boiler,131,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp -GB212,boiler,131,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp -GB212,boiler,131,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp +GB212,boiler,131,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +GB212,boiler,131,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod +GB212,boiler,131,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp +GB212,boiler,131,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp +GB212,boiler,131,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp +GB212,boiler,131,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp +GB212,boiler,131,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress +GB212,boiler,131,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +GB212,boiler,131,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp +GB212,boiler,131,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp GB212,boiler,131,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas GB212,boiler,131,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 -GB212,boiler,131,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr +GB212,boiler,131,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr GB212,boiler,131,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork GB212,boiler,131,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork GB212,boiler,131,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat -GB212,boiler,131,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -GB212,boiler,131,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -GB212,boiler,131,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -GB212,boiler,131,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow -GB212,boiler,131,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock -GB212,boiler,131,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -GB212,boiler,131,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -GB212,boiler,131,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -GB212,boiler,131,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +GB212,boiler,131,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +GB212,boiler,131,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +GB212,boiler,131,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +GB212,boiler,131,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +GB212,boiler,131,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +GB212,boiler,131,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +GB212,boiler,131,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff +GB212,boiler,131,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston +GB212,boiler,131,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff GB212,boiler,131,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon -GB212,boiler,131,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase -GB212,boiler,131,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -GB212,boiler,131,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +GB212,boiler,131,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase +GB212,boiler,131,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend +GB212,boiler,131,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp GB212,boiler,131,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode -GB212,boiler,131,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp +GB212,boiler,131,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp GB212,boiler,131,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -GB212,boiler,131,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +GB212,boiler,131,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp GB212,boiler,131,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump -GB212,boiler,131,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax -GB212,boiler,131,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin +GB212,boiler,131,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax +GB212,boiler,131,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin GB212,boiler,131,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -GB212,boiler,131,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -GB212,boiler,131,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp -GB212,boiler,131,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -GB212,boiler,131,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow -GB212,boiler,131,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -GB212,boiler,131,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +GB212,boiler,131,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay +GB212,boiler,131,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp +GB212,boiler,131,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow +GB212,boiler,131,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow +GB212,boiler,131,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow +GB212,boiler,131,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts GB212,boiler,131,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin GB212,boiler,131,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin GB212,boiler,131,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -GB212,boiler,131,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +GB212,boiler,131,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts GB212,boiler,131,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime GB212,boiler,131,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode GB212,boiler,131,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode -GB212,boiler,131,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber +GB212,boiler,131,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber GB212,boiler,131,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage GB212,boiler,131,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance -GB212,boiler,131,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime +GB212,boiler,131,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime GB212,boiler,131,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate GB212,boiler,131,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops -GB212,boiler,131,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp -GB212,boiler,131,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated -GB212,boiler,131,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp -GB212,boiler,131,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp -GB212,boiler,131,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow -GB212,boiler,131,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus -GB212,boiler,131,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff -GB212,boiler,131,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle -GB212,boiler,131,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp -GB212,boiler,131,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype -GB212,boiler,131,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort -GB212,boiler,131,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 -GB212,boiler,131,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset -GB212,boiler,131,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization -GB212,boiler,131,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -GB212,boiler,131,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp -GB212,boiler,131,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump -GB212,boiler,131,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype -GB212,boiler,131,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston -GB212,boiler,131,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -GB212,boiler,131,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp -GB212,boiler,131,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode -GB212,boiler,131,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc -GB212,boiler,131,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp -GB212,boiler,131,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 -GB212,boiler,131,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow -GB212,boiler,131,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 -GB212,boiler,131,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 -GB212,boiler,131,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated -GB212,boiler,131,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime -GB212,boiler,131,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting -GB212,boiler,131,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging -GB212,boiler,131,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging -GB212,boiler,131,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok -GB212,boiler,131,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive -GB212,boiler,131,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve -GB212,boiler,131,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower -GB212,boiler,131,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp -GB212,boiler,131,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -GB212,boiler,131,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -GB212,boiler,131,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -GB212,boiler,131,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower -GB212,boiler,131,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal -GB212,boiler,131,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -GB212,boiler,131,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww -GC7000F,boiler,132,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +GB212,boiler,131,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp +GB212,boiler,131,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat +GB212,boiler,131,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +GB212,boiler,131,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat +GB212,boiler,131,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +GB212,boiler,131,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 +GB212,boiler,131,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +GB212,boiler,131,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated +GB212,boiler,131,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp +GB212,boiler,131,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp +GB212,boiler,131,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow +GB212,boiler,131,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus +GB212,boiler,131,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff +GB212,boiler,131,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle +GB212,boiler,131,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp +GB212,boiler,131,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type +GB212,boiler,131,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort +GB212,boiler,131,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1 +GB212,boiler,131,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset +GB212,boiler,131,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization +GB212,boiler,131,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower +GB212,boiler,131,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp +GB212,boiler,131,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump +GB212,boiler,131,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype +GB212,boiler,131,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston +GB212,boiler,131,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff +GB212,boiler,131,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp +GB212,boiler,131,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode +GB212,boiler,131,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ +GB212,boiler,131,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp +GB212,boiler,131,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2 +GB212,boiler,131,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow +GB212,boiler,131,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1 +GB212,boiler,131,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2 +GB212,boiler,131,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated +GB212,boiler,131,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime +GB212,boiler,131,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting +GB212,boiler,131,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging +GB212,boiler,131,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging +GB212,boiler,131,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok +GB212,boiler,131,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active +GB212,boiler,131,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve +GB212,boiler,131,setpumppower,set pump power,uint8 (>=0<=100),%,false,sensor.boiler_dhw_set_pump_power,sensor.boiler_dhw_setpumppower +GB212,boiler,131,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp +GB212,boiler,131,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp +GB212,boiler,131,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts +GB212,boiler,131,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm +GB212,boiler,131,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +GB212,boiler,131,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +GB212,boiler,131,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +GB212,boiler,131,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +GC7000F,boiler,132,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset GC7000F,boiler,132,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff GC7000F,boiler,132,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive GC7000F,boiler,132,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -GC7000F,boiler,132,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp -GC7000F,boiler,132,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod -GC7000F,boiler,132,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp -GC7000F,boiler,132,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp -GC7000F,boiler,132,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp -GC7000F,boiler,132,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp -GC7000F,boiler,132,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress -GC7000F,boiler,132,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp -GC7000F,boiler,132,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp -GC7000F,boiler,132,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp +GC7000F,boiler,132,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +GC7000F,boiler,132,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod +GC7000F,boiler,132,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp +GC7000F,boiler,132,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp +GC7000F,boiler,132,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp +GC7000F,boiler,132,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp +GC7000F,boiler,132,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress +GC7000F,boiler,132,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +GC7000F,boiler,132,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp +GC7000F,boiler,132,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp GC7000F,boiler,132,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas GC7000F,boiler,132,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 -GC7000F,boiler,132,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr +GC7000F,boiler,132,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr GC7000F,boiler,132,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork GC7000F,boiler,132,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork GC7000F,boiler,132,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat -GC7000F,boiler,132,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -GC7000F,boiler,132,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -GC7000F,boiler,132,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -GC7000F,boiler,132,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow -GC7000F,boiler,132,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock -GC7000F,boiler,132,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -GC7000F,boiler,132,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -GC7000F,boiler,132,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -GC7000F,boiler,132,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +GC7000F,boiler,132,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +GC7000F,boiler,132,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +GC7000F,boiler,132,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +GC7000F,boiler,132,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +GC7000F,boiler,132,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +GC7000F,boiler,132,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +GC7000F,boiler,132,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff +GC7000F,boiler,132,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston +GC7000F,boiler,132,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff GC7000F,boiler,132,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon -GC7000F,boiler,132,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase -GC7000F,boiler,132,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -GC7000F,boiler,132,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +GC7000F,boiler,132,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase +GC7000F,boiler,132,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend +GC7000F,boiler,132,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp GC7000F,boiler,132,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode -GC7000F,boiler,132,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp +GC7000F,boiler,132,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp GC7000F,boiler,132,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -GC7000F,boiler,132,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +GC7000F,boiler,132,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp GC7000F,boiler,132,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump -GC7000F,boiler,132,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax -GC7000F,boiler,132,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin +GC7000F,boiler,132,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax +GC7000F,boiler,132,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin GC7000F,boiler,132,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -GC7000F,boiler,132,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -GC7000F,boiler,132,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp -GC7000F,boiler,132,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -GC7000F,boiler,132,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow -GC7000F,boiler,132,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -GC7000F,boiler,132,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +GC7000F,boiler,132,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay +GC7000F,boiler,132,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp +GC7000F,boiler,132,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow +GC7000F,boiler,132,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow +GC7000F,boiler,132,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow +GC7000F,boiler,132,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts GC7000F,boiler,132,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin GC7000F,boiler,132,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin GC7000F,boiler,132,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -GC7000F,boiler,132,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +GC7000F,boiler,132,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts GC7000F,boiler,132,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime GC7000F,boiler,132,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode GC7000F,boiler,132,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode -GC7000F,boiler,132,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber +GC7000F,boiler,132,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber GC7000F,boiler,132,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage GC7000F,boiler,132,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance -GC7000F,boiler,132,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime +GC7000F,boiler,132,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime GC7000F,boiler,132,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate GC7000F,boiler,132,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops -GC7000F,boiler,132,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp -GC7000F,boiler,132,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated -GC7000F,boiler,132,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp -GC7000F,boiler,132,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp -GC7000F,boiler,132,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow -GC7000F,boiler,132,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus -GC7000F,boiler,132,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff -GC7000F,boiler,132,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle -GC7000F,boiler,132,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp -GC7000F,boiler,132,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype -GC7000F,boiler,132,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort -GC7000F,boiler,132,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 -GC7000F,boiler,132,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset -GC7000F,boiler,132,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization -GC7000F,boiler,132,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -GC7000F,boiler,132,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp -GC7000F,boiler,132,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump -GC7000F,boiler,132,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype -GC7000F,boiler,132,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston -GC7000F,boiler,132,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -GC7000F,boiler,132,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp -GC7000F,boiler,132,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode -GC7000F,boiler,132,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc -GC7000F,boiler,132,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp -GC7000F,boiler,132,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 -GC7000F,boiler,132,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow -GC7000F,boiler,132,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 -GC7000F,boiler,132,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 -GC7000F,boiler,132,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated -GC7000F,boiler,132,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime -GC7000F,boiler,132,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting -GC7000F,boiler,132,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging -GC7000F,boiler,132,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging -GC7000F,boiler,132,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok -GC7000F,boiler,132,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive -GC7000F,boiler,132,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve -GC7000F,boiler,132,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower -GC7000F,boiler,132,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp -GC7000F,boiler,132,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -GC7000F,boiler,132,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -GC7000F,boiler,132,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -GC7000F,boiler,132,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower -GC7000F,boiler,132,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal -GC7000F,boiler,132,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -GC7000F,boiler,132,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww -Logano GB125/KB195i/Logamatic MC110,boiler,133,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +GC7000F,boiler,132,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp +GC7000F,boiler,132,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat +GC7000F,boiler,132,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +GC7000F,boiler,132,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat +GC7000F,boiler,132,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +GC7000F,boiler,132,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 +GC7000F,boiler,132,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +GC7000F,boiler,132,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated +GC7000F,boiler,132,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp +GC7000F,boiler,132,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp +GC7000F,boiler,132,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow +GC7000F,boiler,132,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus +GC7000F,boiler,132,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff +GC7000F,boiler,132,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle +GC7000F,boiler,132,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp +GC7000F,boiler,132,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type +GC7000F,boiler,132,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort +GC7000F,boiler,132,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1 +GC7000F,boiler,132,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset +GC7000F,boiler,132,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization +GC7000F,boiler,132,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower +GC7000F,boiler,132,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp +GC7000F,boiler,132,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump +GC7000F,boiler,132,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype +GC7000F,boiler,132,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston +GC7000F,boiler,132,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff +GC7000F,boiler,132,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp +GC7000F,boiler,132,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode +GC7000F,boiler,132,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ +GC7000F,boiler,132,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp +GC7000F,boiler,132,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2 +GC7000F,boiler,132,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow +GC7000F,boiler,132,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1 +GC7000F,boiler,132,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2 +GC7000F,boiler,132,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated +GC7000F,boiler,132,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime +GC7000F,boiler,132,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting +GC7000F,boiler,132,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging +GC7000F,boiler,132,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging +GC7000F,boiler,132,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok +GC7000F,boiler,132,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active +GC7000F,boiler,132,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve +GC7000F,boiler,132,setpumppower,set pump power,uint8 (>=0<=100),%,false,sensor.boiler_dhw_set_pump_power,sensor.boiler_dhw_setpumppower +GC7000F,boiler,132,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp +GC7000F,boiler,132,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp +GC7000F,boiler,132,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts +GC7000F,boiler,132,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm +GC7000F,boiler,132,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +GC7000F,boiler,132,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +GC7000F,boiler,132,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +GC7000F,boiler,132,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Logano GB125/KB195i/Logamatic MC110,boiler,133,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Logano GB125/KB195i/Logamatic MC110,boiler,133,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Logano GB125/KB195i/Logamatic MC110,boiler,133,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Logano GB125/KB195i/Logamatic MC110,boiler,133,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Logano GB125/KB195i/Logamatic MC110,boiler,133,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp -Logano GB125/KB195i/Logamatic MC110,boiler,133,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod -Logano GB125/KB195i/Logamatic MC110,boiler,133,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp -Logano GB125/KB195i/Logamatic MC110,boiler,133,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp -Logano GB125/KB195i/Logamatic MC110,boiler,133,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp -Logano GB125/KB195i/Logamatic MC110,boiler,133,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp -Logano GB125/KB195i/Logamatic MC110,boiler,133,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress -Logano GB125/KB195i/Logamatic MC110,boiler,133,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp -Logano GB125/KB195i/Logamatic MC110,boiler,133,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp -Logano GB125/KB195i/Logamatic MC110,boiler,133,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp +Logano GB125/KB195i/Logamatic MC110,boiler,133,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Logano GB125/KB195i/Logamatic MC110,boiler,133,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod +Logano GB125/KB195i/Logamatic MC110,boiler,133,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp +Logano GB125/KB195i/Logamatic MC110,boiler,133,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp +Logano GB125/KB195i/Logamatic MC110,boiler,133,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp +Logano GB125/KB195i/Logamatic MC110,boiler,133,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp +Logano GB125/KB195i/Logamatic MC110,boiler,133,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress +Logano GB125/KB195i/Logamatic MC110,boiler,133,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Logano GB125/KB195i/Logamatic MC110,boiler,133,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp +Logano GB125/KB195i/Logamatic MC110,boiler,133,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Logano GB125/KB195i/Logamatic MC110,boiler,133,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Logano GB125/KB195i/Logamatic MC110,boiler,133,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 -Logano GB125/KB195i/Logamatic MC110,boiler,133,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr +Logano GB125/KB195i/Logamatic MC110,boiler,133,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Logano GB125/KB195i/Logamatic MC110,boiler,133,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Logano GB125/KB195i/Logamatic MC110,boiler,133,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Logano GB125/KB195i/Logamatic MC110,boiler,133,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat -Logano GB125/KB195i/Logamatic MC110,boiler,133,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Logano GB125/KB195i/Logamatic MC110,boiler,133,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Logano GB125/KB195i/Logamatic MC110,boiler,133,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Logano GB125/KB195i/Logamatic MC110,boiler,133,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow -Logano GB125/KB195i/Logamatic MC110,boiler,133,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock -Logano GB125/KB195i/Logamatic MC110,boiler,133,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Logano GB125/KB195i/Logamatic MC110,boiler,133,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Logano GB125/KB195i/Logamatic MC110,boiler,133,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Logano GB125/KB195i/Logamatic MC110,boiler,133,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Logano GB125/KB195i/Logamatic MC110,boiler,133,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Logano GB125/KB195i/Logamatic MC110,boiler,133,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Logano GB125/KB195i/Logamatic MC110,boiler,133,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Logano GB125/KB195i/Logamatic MC110,boiler,133,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Logano GB125/KB195i/Logamatic MC110,boiler,133,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Logano GB125/KB195i/Logamatic MC110,boiler,133,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Logano GB125/KB195i/Logamatic MC110,boiler,133,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff +Logano GB125/KB195i/Logamatic MC110,boiler,133,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston +Logano GB125/KB195i/Logamatic MC110,boiler,133,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Logano GB125/KB195i/Logamatic MC110,boiler,133,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon -Logano GB125/KB195i/Logamatic MC110,boiler,133,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase -Logano GB125/KB195i/Logamatic MC110,boiler,133,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Logano GB125/KB195i/Logamatic MC110,boiler,133,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Logano GB125/KB195i/Logamatic MC110,boiler,133,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase +Logano GB125/KB195i/Logamatic MC110,boiler,133,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend +Logano GB125/KB195i/Logamatic MC110,boiler,133,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Logano GB125/KB195i/Logamatic MC110,boiler,133,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode -Logano GB125/KB195i/Logamatic MC110,boiler,133,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp +Logano GB125/KB195i/Logamatic MC110,boiler,133,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Logano GB125/KB195i/Logamatic MC110,boiler,133,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Logano GB125/KB195i/Logamatic MC110,boiler,133,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Logano GB125/KB195i/Logamatic MC110,boiler,133,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Logano GB125/KB195i/Logamatic MC110,boiler,133,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump -Logano GB125/KB195i/Logamatic MC110,boiler,133,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax -Logano GB125/KB195i/Logamatic MC110,boiler,133,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin +Logano GB125/KB195i/Logamatic MC110,boiler,133,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax +Logano GB125/KB195i/Logamatic MC110,boiler,133,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Logano GB125/KB195i/Logamatic MC110,boiler,133,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Logano GB125/KB195i/Logamatic MC110,boiler,133,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Logano GB125/KB195i/Logamatic MC110,boiler,133,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp -Logano GB125/KB195i/Logamatic MC110,boiler,133,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Logano GB125/KB195i/Logamatic MC110,boiler,133,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow -Logano GB125/KB195i/Logamatic MC110,boiler,133,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Logano GB125/KB195i/Logamatic MC110,boiler,133,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Logano GB125/KB195i/Logamatic MC110,boiler,133,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay +Logano GB125/KB195i/Logamatic MC110,boiler,133,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp +Logano GB125/KB195i/Logamatic MC110,boiler,133,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow +Logano GB125/KB195i/Logamatic MC110,boiler,133,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow +Logano GB125/KB195i/Logamatic MC110,boiler,133,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow +Logano GB125/KB195i/Logamatic MC110,boiler,133,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Logano GB125/KB195i/Logamatic MC110,boiler,133,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Logano GB125/KB195i/Logamatic MC110,boiler,133,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Logano GB125/KB195i/Logamatic MC110,boiler,133,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Logano GB125/KB195i/Logamatic MC110,boiler,133,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Logano GB125/KB195i/Logamatic MC110,boiler,133,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Logano GB125/KB195i/Logamatic MC110,boiler,133,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Logano GB125/KB195i/Logamatic MC110,boiler,133,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Logano GB125/KB195i/Logamatic MC110,boiler,133,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode -Logano GB125/KB195i/Logamatic MC110,boiler,133,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber +Logano GB125/KB195i/Logamatic MC110,boiler,133,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Logano GB125/KB195i/Logamatic MC110,boiler,133,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Logano GB125/KB195i/Logamatic MC110,boiler,133,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance -Logano GB125/KB195i/Logamatic MC110,boiler,133,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime +Logano GB125/KB195i/Logamatic MC110,boiler,133,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Logano GB125/KB195i/Logamatic MC110,boiler,133,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Logano GB125/KB195i/Logamatic MC110,boiler,133,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops -Logano GB125/KB195i/Logamatic MC110,boiler,133,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive -Logano GB125/KB195i/Logamatic MC110,boiler,133,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Logano GB125/KB195i/Logamatic MC110,boiler,133,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Logano GB125/KB195i/Logamatic MC110,boiler,133,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower -Logano GB125/KB195i/Logamatic MC110,boiler,133,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal -Logano GB125/KB195i/Logamatic MC110,boiler,133,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Logano GB125/KB195i/Logamatic MC110,boiler,133,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww -Greenstar 30Ri Compact,boiler,154,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Logano GB125/KB195i/Logamatic MC110,boiler,133,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp +Logano GB125/KB195i/Logamatic MC110,boiler,133,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat +Logano GB125/KB195i/Logamatic MC110,boiler,133,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Logano GB125/KB195i/Logamatic MC110,boiler,133,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat +Logano GB125/KB195i/Logamatic MC110,boiler,133,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Logano GB125/KB195i/Logamatic MC110,boiler,133,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 +Logano GB125/KB195i/Logamatic MC110,boiler,133,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Logano GB125/KB195i/Logamatic MC110,boiler,133,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated +Logano GB125/KB195i/Logamatic MC110,boiler,133,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp +Logano GB125/KB195i/Logamatic MC110,boiler,133,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp +Logano GB125/KB195i/Logamatic MC110,boiler,133,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow +Logano GB125/KB195i/Logamatic MC110,boiler,133,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus +Logano GB125/KB195i/Logamatic MC110,boiler,133,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff +Logano GB125/KB195i/Logamatic MC110,boiler,133,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle +Logano GB125/KB195i/Logamatic MC110,boiler,133,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp +Logano GB125/KB195i/Logamatic MC110,boiler,133,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type +Logano GB125/KB195i/Logamatic MC110,boiler,133,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort +Logano GB125/KB195i/Logamatic MC110,boiler,133,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1 +Logano GB125/KB195i/Logamatic MC110,boiler,133,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset +Logano GB125/KB195i/Logamatic MC110,boiler,133,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization +Logano GB125/KB195i/Logamatic MC110,boiler,133,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower +Logano GB125/KB195i/Logamatic MC110,boiler,133,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp +Logano GB125/KB195i/Logamatic MC110,boiler,133,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump +Logano GB125/KB195i/Logamatic MC110,boiler,133,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype +Logano GB125/KB195i/Logamatic MC110,boiler,133,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston +Logano GB125/KB195i/Logamatic MC110,boiler,133,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff +Logano GB125/KB195i/Logamatic MC110,boiler,133,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp +Logano GB125/KB195i/Logamatic MC110,boiler,133,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode +Logano GB125/KB195i/Logamatic MC110,boiler,133,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ +Logano GB125/KB195i/Logamatic MC110,boiler,133,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp +Logano GB125/KB195i/Logamatic MC110,boiler,133,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2 +Logano GB125/KB195i/Logamatic MC110,boiler,133,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow +Logano GB125/KB195i/Logamatic MC110,boiler,133,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1 +Logano GB125/KB195i/Logamatic MC110,boiler,133,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2 +Logano GB125/KB195i/Logamatic MC110,boiler,133,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated +Logano GB125/KB195i/Logamatic MC110,boiler,133,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime +Logano GB125/KB195i/Logamatic MC110,boiler,133,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting +Logano GB125/KB195i/Logamatic MC110,boiler,133,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging +Logano GB125/KB195i/Logamatic MC110,boiler,133,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging +Logano GB125/KB195i/Logamatic MC110,boiler,133,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok +Logano GB125/KB195i/Logamatic MC110,boiler,133,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active +Logano GB125/KB195i/Logamatic MC110,boiler,133,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve +Logano GB125/KB195i/Logamatic MC110,boiler,133,setpumppower,set pump power,uint8 (>=0<=100),%,false,sensor.boiler_dhw_set_pump_power,sensor.boiler_dhw_setpumppower +Logano GB125/KB195i/Logamatic MC110,boiler,133,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp +Logano GB125/KB195i/Logamatic MC110,boiler,133,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp +Logano GB125/KB195i/Logamatic MC110,boiler,133,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts +Logano GB125/KB195i/Logamatic MC110,boiler,133,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm +Logano GB125/KB195i/Logamatic MC110,boiler,133,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Logano GB125/KB195i/Logamatic MC110,boiler,133,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Logano GB125/KB195i/Logamatic MC110,boiler,133,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Logano GB125/KB195i/Logamatic MC110,boiler,133,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Greenstar 30Ri Compact,boiler,154,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Greenstar 30Ri Compact,boiler,154,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Greenstar 30Ri Compact,boiler,154,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Greenstar 30Ri Compact,boiler,154,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Greenstar 30Ri Compact,boiler,154,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp -Greenstar 30Ri Compact,boiler,154,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod -Greenstar 30Ri Compact,boiler,154,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp -Greenstar 30Ri Compact,boiler,154,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp -Greenstar 30Ri Compact,boiler,154,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp -Greenstar 30Ri Compact,boiler,154,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp -Greenstar 30Ri Compact,boiler,154,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress -Greenstar 30Ri Compact,boiler,154,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp -Greenstar 30Ri Compact,boiler,154,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp -Greenstar 30Ri Compact,boiler,154,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp +Greenstar 30Ri Compact,boiler,154,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Greenstar 30Ri Compact,boiler,154,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod +Greenstar 30Ri Compact,boiler,154,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp +Greenstar 30Ri Compact,boiler,154,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp +Greenstar 30Ri Compact,boiler,154,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp +Greenstar 30Ri Compact,boiler,154,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp +Greenstar 30Ri Compact,boiler,154,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress +Greenstar 30Ri Compact,boiler,154,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Greenstar 30Ri Compact,boiler,154,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp +Greenstar 30Ri Compact,boiler,154,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Greenstar 30Ri Compact,boiler,154,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Greenstar 30Ri Compact,boiler,154,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 -Greenstar 30Ri Compact,boiler,154,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr +Greenstar 30Ri Compact,boiler,154,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Greenstar 30Ri Compact,boiler,154,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Greenstar 30Ri Compact,boiler,154,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Greenstar 30Ri Compact,boiler,154,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat -Greenstar 30Ri Compact,boiler,154,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Greenstar 30Ri Compact,boiler,154,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Greenstar 30Ri Compact,boiler,154,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Greenstar 30Ri Compact,boiler,154,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow -Greenstar 30Ri Compact,boiler,154,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock -Greenstar 30Ri Compact,boiler,154,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Greenstar 30Ri Compact,boiler,154,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Greenstar 30Ri Compact,boiler,154,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Greenstar 30Ri Compact,boiler,154,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Greenstar 30Ri Compact,boiler,154,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Greenstar 30Ri Compact,boiler,154,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Greenstar 30Ri Compact,boiler,154,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Greenstar 30Ri Compact,boiler,154,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Greenstar 30Ri Compact,boiler,154,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Greenstar 30Ri Compact,boiler,154,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Greenstar 30Ri Compact,boiler,154,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff +Greenstar 30Ri Compact,boiler,154,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston +Greenstar 30Ri Compact,boiler,154,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Greenstar 30Ri Compact,boiler,154,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon -Greenstar 30Ri Compact,boiler,154,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase -Greenstar 30Ri Compact,boiler,154,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Greenstar 30Ri Compact,boiler,154,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Greenstar 30Ri Compact,boiler,154,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase +Greenstar 30Ri Compact,boiler,154,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend +Greenstar 30Ri Compact,boiler,154,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Greenstar 30Ri Compact,boiler,154,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode -Greenstar 30Ri Compact,boiler,154,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp +Greenstar 30Ri Compact,boiler,154,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Greenstar 30Ri Compact,boiler,154,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Greenstar 30Ri Compact,boiler,154,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Greenstar 30Ri Compact,boiler,154,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Greenstar 30Ri Compact,boiler,154,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump -Greenstar 30Ri Compact,boiler,154,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax -Greenstar 30Ri Compact,boiler,154,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin +Greenstar 30Ri Compact,boiler,154,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax +Greenstar 30Ri Compact,boiler,154,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Greenstar 30Ri Compact,boiler,154,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Greenstar 30Ri Compact,boiler,154,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Greenstar 30Ri Compact,boiler,154,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp -Greenstar 30Ri Compact,boiler,154,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Greenstar 30Ri Compact,boiler,154,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow -Greenstar 30Ri Compact,boiler,154,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Greenstar 30Ri Compact,boiler,154,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Greenstar 30Ri Compact,boiler,154,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay +Greenstar 30Ri Compact,boiler,154,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp +Greenstar 30Ri Compact,boiler,154,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow +Greenstar 30Ri Compact,boiler,154,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow +Greenstar 30Ri Compact,boiler,154,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow +Greenstar 30Ri Compact,boiler,154,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Greenstar 30Ri Compact,boiler,154,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Greenstar 30Ri Compact,boiler,154,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Greenstar 30Ri Compact,boiler,154,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Greenstar 30Ri Compact,boiler,154,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Greenstar 30Ri Compact,boiler,154,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Greenstar 30Ri Compact,boiler,154,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Greenstar 30Ri Compact,boiler,154,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Greenstar 30Ri Compact,boiler,154,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode -Greenstar 30Ri Compact,boiler,154,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber +Greenstar 30Ri Compact,boiler,154,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Greenstar 30Ri Compact,boiler,154,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Greenstar 30Ri Compact,boiler,154,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance -Greenstar 30Ri Compact,boiler,154,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime +Greenstar 30Ri Compact,boiler,154,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Greenstar 30Ri Compact,boiler,154,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Greenstar 30Ri Compact,boiler,154,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops -Greenstar 30Ri Compact,boiler,154,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp -Greenstar 30Ri Compact,boiler,154,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated -Greenstar 30Ri Compact,boiler,154,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp -Greenstar 30Ri Compact,boiler,154,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp -Greenstar 30Ri Compact,boiler,154,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow -Greenstar 30Ri Compact,boiler,154,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus -Greenstar 30Ri Compact,boiler,154,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff -Greenstar 30Ri Compact,boiler,154,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle -Greenstar 30Ri Compact,boiler,154,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp -Greenstar 30Ri Compact,boiler,154,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype -Greenstar 30Ri Compact,boiler,154,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort -Greenstar 30Ri Compact,boiler,154,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 -Greenstar 30Ri Compact,boiler,154,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset -Greenstar 30Ri Compact,boiler,154,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization -Greenstar 30Ri Compact,boiler,154,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Greenstar 30Ri Compact,boiler,154,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp -Greenstar 30Ri Compact,boiler,154,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump -Greenstar 30Ri Compact,boiler,154,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype -Greenstar 30Ri Compact,boiler,154,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston -Greenstar 30Ri Compact,boiler,154,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Greenstar 30Ri Compact,boiler,154,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp -Greenstar 30Ri Compact,boiler,154,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode -Greenstar 30Ri Compact,boiler,154,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc -Greenstar 30Ri Compact,boiler,154,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp -Greenstar 30Ri Compact,boiler,154,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 -Greenstar 30Ri Compact,boiler,154,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow -Greenstar 30Ri Compact,boiler,154,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 -Greenstar 30Ri Compact,boiler,154,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 -Greenstar 30Ri Compact,boiler,154,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated -Greenstar 30Ri Compact,boiler,154,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime -Greenstar 30Ri Compact,boiler,154,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting -Greenstar 30Ri Compact,boiler,154,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging -Greenstar 30Ri Compact,boiler,154,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging -Greenstar 30Ri Compact,boiler,154,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok -Greenstar 30Ri Compact,boiler,154,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive -Greenstar 30Ri Compact,boiler,154,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve -Greenstar 30Ri Compact,boiler,154,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower -Greenstar 30Ri Compact,boiler,154,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp -Greenstar 30Ri Compact,boiler,154,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Greenstar 30Ri Compact,boiler,154,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Greenstar 30Ri Compact,boiler,154,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Greenstar 30Ri Compact,boiler,154,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower -Greenstar 30Ri Compact,boiler,154,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal -Greenstar 30Ri Compact,boiler,154,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Greenstar 30Ri Compact,boiler,154,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww -Cerapur Aero,boiler,167,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Greenstar 30Ri Compact,boiler,154,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp +Greenstar 30Ri Compact,boiler,154,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat +Greenstar 30Ri Compact,boiler,154,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Greenstar 30Ri Compact,boiler,154,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat +Greenstar 30Ri Compact,boiler,154,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Greenstar 30Ri Compact,boiler,154,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 +Greenstar 30Ri Compact,boiler,154,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Greenstar 30Ri Compact,boiler,154,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated +Greenstar 30Ri Compact,boiler,154,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp +Greenstar 30Ri Compact,boiler,154,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp +Greenstar 30Ri Compact,boiler,154,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow +Greenstar 30Ri Compact,boiler,154,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus +Greenstar 30Ri Compact,boiler,154,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff +Greenstar 30Ri Compact,boiler,154,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle +Greenstar 30Ri Compact,boiler,154,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp +Greenstar 30Ri Compact,boiler,154,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type +Greenstar 30Ri Compact,boiler,154,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort +Greenstar 30Ri Compact,boiler,154,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1 +Greenstar 30Ri Compact,boiler,154,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset +Greenstar 30Ri Compact,boiler,154,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization +Greenstar 30Ri Compact,boiler,154,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower +Greenstar 30Ri Compact,boiler,154,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp +Greenstar 30Ri Compact,boiler,154,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump +Greenstar 30Ri Compact,boiler,154,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype +Greenstar 30Ri Compact,boiler,154,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston +Greenstar 30Ri Compact,boiler,154,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff +Greenstar 30Ri Compact,boiler,154,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp +Greenstar 30Ri Compact,boiler,154,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode +Greenstar 30Ri Compact,boiler,154,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ +Greenstar 30Ri Compact,boiler,154,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp +Greenstar 30Ri Compact,boiler,154,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2 +Greenstar 30Ri Compact,boiler,154,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow +Greenstar 30Ri Compact,boiler,154,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1 +Greenstar 30Ri Compact,boiler,154,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2 +Greenstar 30Ri Compact,boiler,154,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated +Greenstar 30Ri Compact,boiler,154,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime +Greenstar 30Ri Compact,boiler,154,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting +Greenstar 30Ri Compact,boiler,154,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging +Greenstar 30Ri Compact,boiler,154,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging +Greenstar 30Ri Compact,boiler,154,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok +Greenstar 30Ri Compact,boiler,154,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active +Greenstar 30Ri Compact,boiler,154,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve +Greenstar 30Ri Compact,boiler,154,setpumppower,set pump power,uint8 (>=0<=100),%,false,sensor.boiler_dhw_set_pump_power,sensor.boiler_dhw_setpumppower +Greenstar 30Ri Compact,boiler,154,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp +Greenstar 30Ri Compact,boiler,154,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp +Greenstar 30Ri Compact,boiler,154,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts +Greenstar 30Ri Compact,boiler,154,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm +Greenstar 30Ri Compact,boiler,154,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Greenstar 30Ri Compact,boiler,154,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Greenstar 30Ri Compact,boiler,154,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Greenstar 30Ri Compact,boiler,154,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Cerapur Aero,boiler,167,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Cerapur Aero,boiler,167,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Cerapur Aero,boiler,167,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Cerapur Aero,boiler,167,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Cerapur Aero,boiler,167,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp -Cerapur Aero,boiler,167,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod -Cerapur Aero,boiler,167,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp -Cerapur Aero,boiler,167,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp -Cerapur Aero,boiler,167,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp -Cerapur Aero,boiler,167,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp -Cerapur Aero,boiler,167,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress -Cerapur Aero,boiler,167,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp -Cerapur Aero,boiler,167,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp -Cerapur Aero,boiler,167,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp +Cerapur Aero,boiler,167,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Cerapur Aero,boiler,167,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod +Cerapur Aero,boiler,167,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp +Cerapur Aero,boiler,167,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp +Cerapur Aero,boiler,167,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp +Cerapur Aero,boiler,167,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp +Cerapur Aero,boiler,167,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress +Cerapur Aero,boiler,167,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Cerapur Aero,boiler,167,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp +Cerapur Aero,boiler,167,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Cerapur Aero,boiler,167,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Cerapur Aero,boiler,167,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 -Cerapur Aero,boiler,167,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr +Cerapur Aero,boiler,167,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Cerapur Aero,boiler,167,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Cerapur Aero,boiler,167,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Cerapur Aero,boiler,167,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat -Cerapur Aero,boiler,167,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Cerapur Aero,boiler,167,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Cerapur Aero,boiler,167,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Cerapur Aero,boiler,167,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow -Cerapur Aero,boiler,167,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock -Cerapur Aero,boiler,167,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Cerapur Aero,boiler,167,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Cerapur Aero,boiler,167,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Cerapur Aero,boiler,167,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Cerapur Aero,boiler,167,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Cerapur Aero,boiler,167,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Cerapur Aero,boiler,167,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Cerapur Aero,boiler,167,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Cerapur Aero,boiler,167,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Cerapur Aero,boiler,167,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Cerapur Aero,boiler,167,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff +Cerapur Aero,boiler,167,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston +Cerapur Aero,boiler,167,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Cerapur Aero,boiler,167,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon -Cerapur Aero,boiler,167,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase -Cerapur Aero,boiler,167,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Cerapur Aero,boiler,167,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Cerapur Aero,boiler,167,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase +Cerapur Aero,boiler,167,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend +Cerapur Aero,boiler,167,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Cerapur Aero,boiler,167,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode -Cerapur Aero,boiler,167,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp +Cerapur Aero,boiler,167,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Cerapur Aero,boiler,167,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Cerapur Aero,boiler,167,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Cerapur Aero,boiler,167,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Cerapur Aero,boiler,167,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump -Cerapur Aero,boiler,167,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax -Cerapur Aero,boiler,167,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin +Cerapur Aero,boiler,167,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax +Cerapur Aero,boiler,167,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Cerapur Aero,boiler,167,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Cerapur Aero,boiler,167,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Cerapur Aero,boiler,167,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp -Cerapur Aero,boiler,167,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Cerapur Aero,boiler,167,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow -Cerapur Aero,boiler,167,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Cerapur Aero,boiler,167,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Cerapur Aero,boiler,167,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay +Cerapur Aero,boiler,167,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp +Cerapur Aero,boiler,167,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow +Cerapur Aero,boiler,167,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow +Cerapur Aero,boiler,167,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow +Cerapur Aero,boiler,167,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Cerapur Aero,boiler,167,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Cerapur Aero,boiler,167,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Cerapur Aero,boiler,167,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Cerapur Aero,boiler,167,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Cerapur Aero,boiler,167,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Cerapur Aero,boiler,167,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Cerapur Aero,boiler,167,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Cerapur Aero,boiler,167,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode -Cerapur Aero,boiler,167,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber +Cerapur Aero,boiler,167,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Cerapur Aero,boiler,167,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Cerapur Aero,boiler,167,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance -Cerapur Aero,boiler,167,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime +Cerapur Aero,boiler,167,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Cerapur Aero,boiler,167,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Cerapur Aero,boiler,167,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops -Cerapur Aero,boiler,167,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp -Cerapur Aero,boiler,167,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated -Cerapur Aero,boiler,167,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp -Cerapur Aero,boiler,167,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp -Cerapur Aero,boiler,167,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow -Cerapur Aero,boiler,167,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus -Cerapur Aero,boiler,167,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff -Cerapur Aero,boiler,167,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle -Cerapur Aero,boiler,167,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp -Cerapur Aero,boiler,167,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype -Cerapur Aero,boiler,167,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort -Cerapur Aero,boiler,167,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 -Cerapur Aero,boiler,167,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset -Cerapur Aero,boiler,167,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization -Cerapur Aero,boiler,167,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Cerapur Aero,boiler,167,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp -Cerapur Aero,boiler,167,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump -Cerapur Aero,boiler,167,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype -Cerapur Aero,boiler,167,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston -Cerapur Aero,boiler,167,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Cerapur Aero,boiler,167,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp -Cerapur Aero,boiler,167,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode -Cerapur Aero,boiler,167,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc -Cerapur Aero,boiler,167,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp -Cerapur Aero,boiler,167,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 -Cerapur Aero,boiler,167,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow -Cerapur Aero,boiler,167,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 -Cerapur Aero,boiler,167,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 -Cerapur Aero,boiler,167,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated -Cerapur Aero,boiler,167,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime -Cerapur Aero,boiler,167,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting -Cerapur Aero,boiler,167,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging -Cerapur Aero,boiler,167,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging -Cerapur Aero,boiler,167,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok -Cerapur Aero,boiler,167,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive -Cerapur Aero,boiler,167,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve -Cerapur Aero,boiler,167,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower -Cerapur Aero,boiler,167,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp -Cerapur Aero,boiler,167,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Cerapur Aero,boiler,167,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Cerapur Aero,boiler,167,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Cerapur Aero,boiler,167,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower -Cerapur Aero,boiler,167,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal -Cerapur Aero,boiler,167,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Cerapur Aero,boiler,167,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww -Hybrid Heatpump,boiler,168,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Cerapur Aero,boiler,167,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp +Cerapur Aero,boiler,167,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat +Cerapur Aero,boiler,167,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Cerapur Aero,boiler,167,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat +Cerapur Aero,boiler,167,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Cerapur Aero,boiler,167,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 +Cerapur Aero,boiler,167,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Cerapur Aero,boiler,167,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated +Cerapur Aero,boiler,167,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp +Cerapur Aero,boiler,167,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp +Cerapur Aero,boiler,167,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow +Cerapur Aero,boiler,167,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus +Cerapur Aero,boiler,167,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff +Cerapur Aero,boiler,167,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle +Cerapur Aero,boiler,167,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp +Cerapur Aero,boiler,167,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type +Cerapur Aero,boiler,167,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort +Cerapur Aero,boiler,167,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1 +Cerapur Aero,boiler,167,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset +Cerapur Aero,boiler,167,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization +Cerapur Aero,boiler,167,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower +Cerapur Aero,boiler,167,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp +Cerapur Aero,boiler,167,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump +Cerapur Aero,boiler,167,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype +Cerapur Aero,boiler,167,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston +Cerapur Aero,boiler,167,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff +Cerapur Aero,boiler,167,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp +Cerapur Aero,boiler,167,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode +Cerapur Aero,boiler,167,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ +Cerapur Aero,boiler,167,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp +Cerapur Aero,boiler,167,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2 +Cerapur Aero,boiler,167,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow +Cerapur Aero,boiler,167,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1 +Cerapur Aero,boiler,167,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2 +Cerapur Aero,boiler,167,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated +Cerapur Aero,boiler,167,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime +Cerapur Aero,boiler,167,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting +Cerapur Aero,boiler,167,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging +Cerapur Aero,boiler,167,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging +Cerapur Aero,boiler,167,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok +Cerapur Aero,boiler,167,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active +Cerapur Aero,boiler,167,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve +Cerapur Aero,boiler,167,setpumppower,set pump power,uint8 (>=0<=100),%,false,sensor.boiler_dhw_set_pump_power,sensor.boiler_dhw_setpumppower +Cerapur Aero,boiler,167,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp +Cerapur Aero,boiler,167,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp +Cerapur Aero,boiler,167,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts +Cerapur Aero,boiler,167,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm +Cerapur Aero,boiler,167,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Cerapur Aero,boiler,167,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Cerapur Aero,boiler,167,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Cerapur Aero,boiler,167,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Hybrid Heatpump,boiler,168,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Hybrid Heatpump,boiler,168,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Hybrid Heatpump,boiler,168,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Hybrid Heatpump,boiler,168,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Hybrid Heatpump,boiler,168,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp -Hybrid Heatpump,boiler,168,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod -Hybrid Heatpump,boiler,168,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp -Hybrid Heatpump,boiler,168,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp -Hybrid Heatpump,boiler,168,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp -Hybrid Heatpump,boiler,168,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp -Hybrid Heatpump,boiler,168,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress -Hybrid Heatpump,boiler,168,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp -Hybrid Heatpump,boiler,168,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp -Hybrid Heatpump,boiler,168,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp +Hybrid Heatpump,boiler,168,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Hybrid Heatpump,boiler,168,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod +Hybrid Heatpump,boiler,168,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp +Hybrid Heatpump,boiler,168,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp +Hybrid Heatpump,boiler,168,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp +Hybrid Heatpump,boiler,168,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp +Hybrid Heatpump,boiler,168,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress +Hybrid Heatpump,boiler,168,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Hybrid Heatpump,boiler,168,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp +Hybrid Heatpump,boiler,168,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Hybrid Heatpump,boiler,168,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Hybrid Heatpump,boiler,168,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 -Hybrid Heatpump,boiler,168,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr +Hybrid Heatpump,boiler,168,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Hybrid Heatpump,boiler,168,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Hybrid Heatpump,boiler,168,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Hybrid Heatpump,boiler,168,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat -Hybrid Heatpump,boiler,168,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Hybrid Heatpump,boiler,168,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Hybrid Heatpump,boiler,168,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Hybrid Heatpump,boiler,168,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow -Hybrid Heatpump,boiler,168,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock -Hybrid Heatpump,boiler,168,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Hybrid Heatpump,boiler,168,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Hybrid Heatpump,boiler,168,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Hybrid Heatpump,boiler,168,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Hybrid Heatpump,boiler,168,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Hybrid Heatpump,boiler,168,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Hybrid Heatpump,boiler,168,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Hybrid Heatpump,boiler,168,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Hybrid Heatpump,boiler,168,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Hybrid Heatpump,boiler,168,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Hybrid Heatpump,boiler,168,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff +Hybrid Heatpump,boiler,168,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston +Hybrid Heatpump,boiler,168,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Hybrid Heatpump,boiler,168,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon -Hybrid Heatpump,boiler,168,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase -Hybrid Heatpump,boiler,168,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Hybrid Heatpump,boiler,168,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Hybrid Heatpump,boiler,168,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase +Hybrid Heatpump,boiler,168,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend +Hybrid Heatpump,boiler,168,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Hybrid Heatpump,boiler,168,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode -Hybrid Heatpump,boiler,168,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp +Hybrid Heatpump,boiler,168,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Hybrid Heatpump,boiler,168,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Hybrid Heatpump,boiler,168,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Hybrid Heatpump,boiler,168,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Hybrid Heatpump,boiler,168,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump -Hybrid Heatpump,boiler,168,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax -Hybrid Heatpump,boiler,168,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin +Hybrid Heatpump,boiler,168,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax +Hybrid Heatpump,boiler,168,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Hybrid Heatpump,boiler,168,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Hybrid Heatpump,boiler,168,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Hybrid Heatpump,boiler,168,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp -Hybrid Heatpump,boiler,168,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Hybrid Heatpump,boiler,168,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow -Hybrid Heatpump,boiler,168,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Hybrid Heatpump,boiler,168,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Hybrid Heatpump,boiler,168,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay +Hybrid Heatpump,boiler,168,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp +Hybrid Heatpump,boiler,168,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow +Hybrid Heatpump,boiler,168,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow +Hybrid Heatpump,boiler,168,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow +Hybrid Heatpump,boiler,168,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Hybrid Heatpump,boiler,168,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Hybrid Heatpump,boiler,168,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Hybrid Heatpump,boiler,168,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Hybrid Heatpump,boiler,168,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Hybrid Heatpump,boiler,168,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Hybrid Heatpump,boiler,168,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Hybrid Heatpump,boiler,168,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Hybrid Heatpump,boiler,168,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode -Hybrid Heatpump,boiler,168,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber +Hybrid Heatpump,boiler,168,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Hybrid Heatpump,boiler,168,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Hybrid Heatpump,boiler,168,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance -Hybrid Heatpump,boiler,168,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime +Hybrid Heatpump,boiler,168,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Hybrid Heatpump,boiler,168,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Hybrid Heatpump,boiler,168,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops -Hybrid Heatpump,boiler,168,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp -Hybrid Heatpump,boiler,168,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated -Hybrid Heatpump,boiler,168,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp -Hybrid Heatpump,boiler,168,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp -Hybrid Heatpump,boiler,168,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow -Hybrid Heatpump,boiler,168,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus -Hybrid Heatpump,boiler,168,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff -Hybrid Heatpump,boiler,168,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle -Hybrid Heatpump,boiler,168,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp -Hybrid Heatpump,boiler,168,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype -Hybrid Heatpump,boiler,168,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort -Hybrid Heatpump,boiler,168,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 -Hybrid Heatpump,boiler,168,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset -Hybrid Heatpump,boiler,168,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization -Hybrid Heatpump,boiler,168,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Hybrid Heatpump,boiler,168,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp -Hybrid Heatpump,boiler,168,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump -Hybrid Heatpump,boiler,168,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype -Hybrid Heatpump,boiler,168,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston -Hybrid Heatpump,boiler,168,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Hybrid Heatpump,boiler,168,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp -Hybrid Heatpump,boiler,168,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode -Hybrid Heatpump,boiler,168,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc -Hybrid Heatpump,boiler,168,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp -Hybrid Heatpump,boiler,168,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 -Hybrid Heatpump,boiler,168,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow -Hybrid Heatpump,boiler,168,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 -Hybrid Heatpump,boiler,168,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 -Hybrid Heatpump,boiler,168,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated -Hybrid Heatpump,boiler,168,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime -Hybrid Heatpump,boiler,168,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting -Hybrid Heatpump,boiler,168,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging -Hybrid Heatpump,boiler,168,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging -Hybrid Heatpump,boiler,168,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok -Hybrid Heatpump,boiler,168,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive -Hybrid Heatpump,boiler,168,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve -Hybrid Heatpump,boiler,168,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower -Hybrid Heatpump,boiler,168,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp -Hybrid Heatpump,boiler,168,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Hybrid Heatpump,boiler,168,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Hybrid Heatpump,boiler,168,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Hybrid Heatpump,boiler,168,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower -Hybrid Heatpump,boiler,168,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal -Hybrid Heatpump,boiler,168,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Hybrid Heatpump,boiler,168,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww -Logano GB212,boiler,170,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Hybrid Heatpump,boiler,168,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp +Hybrid Heatpump,boiler,168,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat +Hybrid Heatpump,boiler,168,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Hybrid Heatpump,boiler,168,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat +Hybrid Heatpump,boiler,168,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Hybrid Heatpump,boiler,168,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 +Hybrid Heatpump,boiler,168,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Hybrid Heatpump,boiler,168,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated +Hybrid Heatpump,boiler,168,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp +Hybrid Heatpump,boiler,168,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp +Hybrid Heatpump,boiler,168,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow +Hybrid Heatpump,boiler,168,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus +Hybrid Heatpump,boiler,168,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff +Hybrid Heatpump,boiler,168,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle +Hybrid Heatpump,boiler,168,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp +Hybrid Heatpump,boiler,168,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type +Hybrid Heatpump,boiler,168,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort +Hybrid Heatpump,boiler,168,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1 +Hybrid Heatpump,boiler,168,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset +Hybrid Heatpump,boiler,168,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization +Hybrid Heatpump,boiler,168,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower +Hybrid Heatpump,boiler,168,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp +Hybrid Heatpump,boiler,168,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump +Hybrid Heatpump,boiler,168,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype +Hybrid Heatpump,boiler,168,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston +Hybrid Heatpump,boiler,168,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff +Hybrid Heatpump,boiler,168,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp +Hybrid Heatpump,boiler,168,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode +Hybrid Heatpump,boiler,168,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ +Hybrid Heatpump,boiler,168,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp +Hybrid Heatpump,boiler,168,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2 +Hybrid Heatpump,boiler,168,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow +Hybrid Heatpump,boiler,168,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1 +Hybrid Heatpump,boiler,168,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2 +Hybrid Heatpump,boiler,168,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated +Hybrid Heatpump,boiler,168,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime +Hybrid Heatpump,boiler,168,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting +Hybrid Heatpump,boiler,168,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging +Hybrid Heatpump,boiler,168,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging +Hybrid Heatpump,boiler,168,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok +Hybrid Heatpump,boiler,168,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active +Hybrid Heatpump,boiler,168,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve +Hybrid Heatpump,boiler,168,setpumppower,set pump power,uint8 (>=0<=100),%,false,sensor.boiler_dhw_set_pump_power,sensor.boiler_dhw_setpumppower +Hybrid Heatpump,boiler,168,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp +Hybrid Heatpump,boiler,168,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp +Hybrid Heatpump,boiler,168,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts +Hybrid Heatpump,boiler,168,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm +Hybrid Heatpump,boiler,168,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Hybrid Heatpump,boiler,168,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Hybrid Heatpump,boiler,168,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Hybrid Heatpump,boiler,168,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Logano GB212,boiler,170,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Logano GB212,boiler,170,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Logano GB212,boiler,170,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Logano GB212,boiler,170,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Logano GB212,boiler,170,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp -Logano GB212,boiler,170,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod -Logano GB212,boiler,170,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp -Logano GB212,boiler,170,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp -Logano GB212,boiler,170,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp -Logano GB212,boiler,170,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp -Logano GB212,boiler,170,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress -Logano GB212,boiler,170,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp -Logano GB212,boiler,170,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp -Logano GB212,boiler,170,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp +Logano GB212,boiler,170,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Logano GB212,boiler,170,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod +Logano GB212,boiler,170,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp +Logano GB212,boiler,170,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp +Logano GB212,boiler,170,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp +Logano GB212,boiler,170,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp +Logano GB212,boiler,170,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress +Logano GB212,boiler,170,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Logano GB212,boiler,170,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp +Logano GB212,boiler,170,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Logano GB212,boiler,170,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Logano GB212,boiler,170,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 -Logano GB212,boiler,170,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr +Logano GB212,boiler,170,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Logano GB212,boiler,170,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Logano GB212,boiler,170,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Logano GB212,boiler,170,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat -Logano GB212,boiler,170,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Logano GB212,boiler,170,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Logano GB212,boiler,170,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Logano GB212,boiler,170,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow -Logano GB212,boiler,170,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock -Logano GB212,boiler,170,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Logano GB212,boiler,170,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Logano GB212,boiler,170,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Logano GB212,boiler,170,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Logano GB212,boiler,170,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Logano GB212,boiler,170,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Logano GB212,boiler,170,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Logano GB212,boiler,170,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Logano GB212,boiler,170,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Logano GB212,boiler,170,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Logano GB212,boiler,170,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff +Logano GB212,boiler,170,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston +Logano GB212,boiler,170,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Logano GB212,boiler,170,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon -Logano GB212,boiler,170,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase -Logano GB212,boiler,170,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Logano GB212,boiler,170,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Logano GB212,boiler,170,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase +Logano GB212,boiler,170,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend +Logano GB212,boiler,170,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Logano GB212,boiler,170,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode -Logano GB212,boiler,170,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp +Logano GB212,boiler,170,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Logano GB212,boiler,170,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Logano GB212,boiler,170,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Logano GB212,boiler,170,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Logano GB212,boiler,170,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump -Logano GB212,boiler,170,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax -Logano GB212,boiler,170,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin +Logano GB212,boiler,170,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax +Logano GB212,boiler,170,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Logano GB212,boiler,170,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Logano GB212,boiler,170,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Logano GB212,boiler,170,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp -Logano GB212,boiler,170,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Logano GB212,boiler,170,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow -Logano GB212,boiler,170,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Logano GB212,boiler,170,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Logano GB212,boiler,170,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay +Logano GB212,boiler,170,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp +Logano GB212,boiler,170,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow +Logano GB212,boiler,170,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow +Logano GB212,boiler,170,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow +Logano GB212,boiler,170,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Logano GB212,boiler,170,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Logano GB212,boiler,170,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Logano GB212,boiler,170,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Logano GB212,boiler,170,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Logano GB212,boiler,170,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Logano GB212,boiler,170,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Logano GB212,boiler,170,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Logano GB212,boiler,170,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode -Logano GB212,boiler,170,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber +Logano GB212,boiler,170,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Logano GB212,boiler,170,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Logano GB212,boiler,170,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance -Logano GB212,boiler,170,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime +Logano GB212,boiler,170,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Logano GB212,boiler,170,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Logano GB212,boiler,170,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops -Logano GB212,boiler,170,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp -Logano GB212,boiler,170,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated -Logano GB212,boiler,170,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp -Logano GB212,boiler,170,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp -Logano GB212,boiler,170,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow -Logano GB212,boiler,170,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus -Logano GB212,boiler,170,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff -Logano GB212,boiler,170,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle -Logano GB212,boiler,170,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp -Logano GB212,boiler,170,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype -Logano GB212,boiler,170,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort -Logano GB212,boiler,170,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 -Logano GB212,boiler,170,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset -Logano GB212,boiler,170,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization -Logano GB212,boiler,170,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Logano GB212,boiler,170,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp -Logano GB212,boiler,170,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump -Logano GB212,boiler,170,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype -Logano GB212,boiler,170,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston -Logano GB212,boiler,170,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Logano GB212,boiler,170,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp -Logano GB212,boiler,170,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode -Logano GB212,boiler,170,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc -Logano GB212,boiler,170,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp -Logano GB212,boiler,170,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 -Logano GB212,boiler,170,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow -Logano GB212,boiler,170,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 -Logano GB212,boiler,170,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 -Logano GB212,boiler,170,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated -Logano GB212,boiler,170,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime -Logano GB212,boiler,170,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting -Logano GB212,boiler,170,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging -Logano GB212,boiler,170,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging -Logano GB212,boiler,170,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok -Logano GB212,boiler,170,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive -Logano GB212,boiler,170,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve -Logano GB212,boiler,170,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower -Logano GB212,boiler,170,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp -Logano GB212,boiler,170,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Logano GB212,boiler,170,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Logano GB212,boiler,170,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Logano GB212,boiler,170,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower -Logano GB212,boiler,170,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal -Logano GB212,boiler,170,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Logano GB212,boiler,170,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Logano GB212,boiler,170,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp +Logano GB212,boiler,170,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat +Logano GB212,boiler,170,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Logano GB212,boiler,170,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat +Logano GB212,boiler,170,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Logano GB212,boiler,170,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 +Logano GB212,boiler,170,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Logano GB212,boiler,170,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated +Logano GB212,boiler,170,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp +Logano GB212,boiler,170,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp +Logano GB212,boiler,170,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow +Logano GB212,boiler,170,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus +Logano GB212,boiler,170,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff +Logano GB212,boiler,170,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle +Logano GB212,boiler,170,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp +Logano GB212,boiler,170,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type +Logano GB212,boiler,170,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort +Logano GB212,boiler,170,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1 +Logano GB212,boiler,170,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset +Logano GB212,boiler,170,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization +Logano GB212,boiler,170,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower +Logano GB212,boiler,170,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp +Logano GB212,boiler,170,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump +Logano GB212,boiler,170,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype +Logano GB212,boiler,170,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston +Logano GB212,boiler,170,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff +Logano GB212,boiler,170,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp +Logano GB212,boiler,170,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode +Logano GB212,boiler,170,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ +Logano GB212,boiler,170,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp +Logano GB212,boiler,170,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2 +Logano GB212,boiler,170,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow +Logano GB212,boiler,170,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1 +Logano GB212,boiler,170,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2 +Logano GB212,boiler,170,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated +Logano GB212,boiler,170,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime +Logano GB212,boiler,170,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting +Logano GB212,boiler,170,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging +Logano GB212,boiler,170,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging +Logano GB212,boiler,170,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok +Logano GB212,boiler,170,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active +Logano GB212,boiler,170,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve +Logano GB212,boiler,170,setpumppower,set pump power,uint8 (>=0<=100),%,false,sensor.boiler_dhw_set_pump_power,sensor.boiler_dhw_setpumppower +Logano GB212,boiler,170,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp +Logano GB212,boiler,170,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp +Logano GB212,boiler,170,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts +Logano GB212,boiler,170,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm +Logano GB212,boiler,170,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Logano GB212,boiler,170,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Logano GB212,boiler,170,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Logano GB212,boiler,170,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgww,energy,ulong (>=0<=167772),kWh,false,sensor.boiler_energy,sensor.boiler_nrgww -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgheat,energy heating,ulong (>=0<=167772),kWh,false,sensor.boiler_energy_heating,sensor.boiler_nrgheat -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,metertotal,meter total,ulong (>=0<=167772),kWh,false,sensor.boiler_meter_total,sensor.boiler_metertotal -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,metercomp,meter compressor,ulong (>=0<=167772),kWh,false,sensor.boiler_meter_compressor,sensor.boiler_metercomp -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,metereheat,meter e-heater,ulong (>=0<=167772),kWh,false,sensor.boiler_meter_e-heater,sensor.boiler_metereheat -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,meterheat,meter heating,ulong (>=0<=167772),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,meterww,meter,ulong (>=0<=167772),kWh,false,sensor.boiler_meter,sensor.boiler_meterww +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgdhw,energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_energy,sensor.boiler_dhw_nrgdhw +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_energy_heating,sensor.boiler_nrgheat +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_total,sensor.boiler_metertotal +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_compressor,sensor.boiler_metercomp +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_e-heater,sensor.boiler_metereheat +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,meterdhw,meter,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimetotal,heatpump total uptime,time (>=0<=279620),minutes,false,sensor.boiler_heatpump_total_uptime,sensor.boiler_uptimetotal Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimecontrol,total operating time heat,time (>=0<=279620),minutes,false,sensor.boiler_total_operating_time_heat,sensor.boiler_uptimecontrol Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimecompheating,operating time compressor heating,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_heating,sensor.boiler_uptimecompheating Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimecompcooling,operating time compressor cooling,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_cooling,sensor.boiler_uptimecompcooling -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimecompww,operating time compressor,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor,sensor.boiler_uptimecompww +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimecompdhw,operating time compressor,time (>=0<=279620),minutes,false,sensor.boiler_dhw_operating_time_compressor,sensor.boiler_dhw_uptimecompdhw Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimecomppool,operating time compressor pool,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_pool,sensor.boiler_uptimecomppool -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,totalcompstarts,total compressor control starts,ulong (>=0<=16777213), ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingstarts,heating control starts,ulong (>=0<=16777213), ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,coolingstarts,cooling control starts,ulong (>=0<=16777213), ,false,sensor.boiler_cooling_control_starts,sensor.boiler_coolingstarts -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwstarts2,control starts2,ulong (>=0<=16777213), ,false,sensor.boiler_control_starts2,sensor.boiler_wwstarts2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,poolstarts,pool control starts,ulong (>=0<=16777213), ,false,sensor.boiler_pool_control_starts,sensor.boiler_poolstarts -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconstotal,total energy consumption,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscomptotal,total energy consumption compressor,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscompheating,energy consumption compressor heating,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscompww,energy consumption compressor,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor,sensor.boiler_nrgconscompww -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscompcooling,energy consumption compressor cooling,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscomppool,energy consumption compressor pool,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxelecheatnrgconstotal,total aux elec. heater energy consumption,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,ulong (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxelecheatnrgconsww,aux elec. heater energy consumption,ulong (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconsww -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxelecheatnrgconspool,aux elec. heater energy consumption pool,ulong (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsupptotal,total energy supplied,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsuppheating,total energy supplied heating,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsuppww,total energy warm supplied,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_warm_supplied,sensor.boiler_nrgsuppww -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsuppcooling,total energy supplied cooling,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsupppool,total energy supplied pool,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hppower,compressor power output,uint (>=0<=25),kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpmaxpower,compressor max power,uint (>=0<=100),%,true,number.boiler_compressor_max_power,number.boiler_hpmaxpower -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpsetdiffpress,set differental pressure,uint (>=150<=750),mbar,true,number.boiler_set_differental_pressure,number.boiler_hpsetdiffpress +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,totalcompstarts,total compressor control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingstarts,heating control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,coolingstarts,cooling control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_cooling_control_starts,sensor.boiler_coolingstarts +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,starts2,control starts2,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_control_starts2,sensor.boiler_dhw_starts2 +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,poolstarts,pool control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_pool_control_starts,sensor.boiler_poolstarts +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconstotal,total energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscomptotal,total energy consumption compressor,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscompheating,energy consumption compressor heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscompdhw,energy consumption compressor,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_energy_consumption_compressor,sensor.boiler_dhw_nrgconscompdhw +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscompcooling,energy consumption compressor cooling,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscomppool,energy consumption compressor pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxelecheatnrgconstotal,total aux elec. heater energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxelecheatnrgconsdhw,aux elec. heater energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_aux_elec._heater_energy_consumption,sensor.boiler_dhw_auxelecheatnrgconsdhw +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxelecheatnrgconspool,aux elec. heater energy consumption pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsupptotal,total energy supplied,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsuppheating,total energy supplied heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsuppdhw,total energy warm supplied,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_total_energy_warm_supplied,sensor.boiler_dhw_nrgsuppdhw +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsuppcooling,total energy supplied cooling,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsupppool,total energy supplied pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hppower,compressor power output,uint8 (>=0<=25),kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpmaxpower,compressor max power,uint8 (>=0<=100),%,true,number.boiler_compressor_max_power,number.boiler_hpmaxpower +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpsetdiffpress,set differental pressure,uint8 (>=150<=750),mbar,true,number.boiler_set_differental_pressure,number.boiler_hpsetdiffpress Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpcompon,hp compressor,boolean, ,false,binary_sensor.boiler_hp_compressor,binary_sensor.boiler_hpcompon Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpactivity,compressor activity,enum [none\|heating\|cooling\|hot water\|pool\|unknown\|defrost], ,false,sensor.boiler_compressor_activity,sensor.boiler_hpactivity -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpbrinepumpspd,brine pump speed,uint (>=0<=100),%,false,sensor.boiler_brine_pump_speed,sensor.boiler_hpbrinepumpspd +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpbrinepumpspd,brine pump speed,uint8 (>=0<=100),%,false,sensor.boiler_brine_pump_speed,sensor.boiler_hpbrinepumpspd Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpswitchvalve,switch valve,boolean, ,false,binary_sensor.boiler_switch_valve,binary_sensor.boiler_hpswitchvalve -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpcompspd,compressor speed,uint (>=0<=100),%,false,sensor.boiler_compressor_speed,sensor.boiler_hpcompspd -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpcircspd,circulation pump speed,uint (>=0<=100),%,false,sensor.boiler_circulation_pump_speed,sensor.boiler_hpcircspd -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpbrinein,brine in/evaporator,short (>=-3199<=3199),C,false,sensor.boiler_brine_in/evaporator,sensor.boiler_hpbrinein -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpbrineout,brine out/condenser,short (>=-3199<=3199),C,false,sensor.boiler_brine_out/condenser,sensor.boiler_hpbrineout -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptc0,heat carrier return (TC0),short (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_return_(TC0),sensor.boiler_hptc0 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptc1,heat carrier forward (TC1),short (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_forward_(TC1),sensor.boiler_hptc1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptc3,condenser temperature (TC3),short (>=-3199<=3199),C,false,sensor.boiler_condenser_temperature_(TC3),sensor.boiler_hptc3 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptr1,compressor temperature (TR1),short (>=-3199<=3199),C,false,sensor.boiler_compressor_temperature_(TR1),sensor.boiler_hptr1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptr3,refrigerant temperature liquid side (condenser output) (TR3),short (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.boiler_hptr3 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptr4,evaporator inlet temperature (TR4),short (>=-3199<=3199),C,false,sensor.boiler_evaporator_inlet_temperature_(TR4),sensor.boiler_hptr4 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptr5,compressor inlet temperature (TR5),short (>=-3199<=3199),C,false,sensor.boiler_compressor_inlet_temperature_(TR5),sensor.boiler_hptr5 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptr6,compressor outlet temperature (TR6),short (>=-3199<=3199),C,false,sensor.boiler_compressor_outlet_temperature_(TR6),sensor.boiler_hptr6 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptr7,refrigerant temperature gas side (condenser input) (TR7),short (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7),sensor.boiler_hptr7 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptl2,air inlet temperature (TL2),short (>=-3199<=3199),C,false,sensor.boiler_air_inlet_temperature_(TL2),sensor.boiler_hptl2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hppl1,low pressure side temperature (PL1),short (>=-3199<=3199),C,false,sensor.boiler_low_pressure_side_temperature_(PL1),sensor.boiler_hppl1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpph1,high pressure side temperature (PH1),short (>=-3199<=3199),C,false,sensor.boiler_high_pressure_side_temperature_(PH1),sensor.boiler_hpph1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpta4,drain pan temp (TA4),short (>=-3199<=3199),C,false,sensor.boiler_drain_pan_temp_(TA4),sensor.boiler_hpta4 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptw1,reservoir temp (TW1),short (>=-3199<=3199),C,false,sensor.boiler_reservoir_temp_(TW1),sensor.boiler_hptw1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,poolsettemp,pool set temperature,uint (>=0<=127),C,true,number.boiler_pool_set_temperature,number.boiler_poolsettemp +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpcompspd,compressor speed,uint8 (>=0<=100),%,false,sensor.boiler_compressor_speed,sensor.boiler_hpcompspd +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpcircspd,circulation pump speed,uint8 (>=0<=100),%,false,sensor.boiler_circulation_pump_speed,sensor.boiler_hpcircspd +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpbrinein,brine in/evaporator,int16 (>=-3199<=3199),C,false,sensor.boiler_brine_in/evaporator,sensor.boiler_hpbrinein +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpbrineout,brine out/condenser,int16 (>=-3199<=3199),C,false,sensor.boiler_brine_out/condenser,sensor.boiler_hpbrineout +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptc0,heat carrier return (TC0),int16 (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_return_(TC0),sensor.boiler_hptc0 +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptc1,heat carrier forward (TC1),int16 (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_forward_(TC1),sensor.boiler_hptc1 +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptc3,condenser temperature (TC3),int16 (>=-3199<=3199),C,false,sensor.boiler_condenser_temperature_(TC3),sensor.boiler_hptc3 +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptr1,compressor temperature (TR1),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_temperature_(TR1),sensor.boiler_hptr1 +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptr3,refrigerant temperature liquid side (condenser output) (TR3),int16 (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.boiler_hptr3 +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptr4,evaporator inlet temperature (TR4),int16 (>=-3199<=3199),C,false,sensor.boiler_evaporator_inlet_temperature_(TR4),sensor.boiler_hptr4 +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptr5,compressor inlet temperature (TR5),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_inlet_temperature_(TR5),sensor.boiler_hptr5 +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptr6,compressor outlet temperature (TR6),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_outlet_temperature_(TR6),sensor.boiler_hptr6 +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptr7,refrigerant temperature gas side (condenser input) (TR7),int16 (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7),sensor.boiler_hptr7 +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptl2,air inlet temperature (TL2),int16 (>=-3199<=3199),C,false,sensor.boiler_air_inlet_temperature_(TL2),sensor.boiler_hptl2 +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hppl1,low pressure side temperature (PL1),int16 (>=-3199<=3199),C,false,sensor.boiler_low_pressure_side_temperature_(PL1),sensor.boiler_hppl1 +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpph1,high pressure side temperature (PH1),int16 (>=-3199<=3199),C,false,sensor.boiler_high_pressure_side_temperature_(PH1),sensor.boiler_hpph1 +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpta4,drain pan temp (TA4),int16 (>=-3199<=3199),C,false,sensor.boiler_drain_pan_temp_(TA4),sensor.boiler_hpta4 +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptw1,reservoir temp (TW1),int16 (>=-3199<=3199),C,false,sensor.boiler_reservoir_temp_(TW1),sensor.boiler_hptw1 +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,poolsettemp,pool set temperature,uint8 (>=0<=127),C,true,number.boiler_pool_set_temperature,number.boiler_poolsettemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hp4way,4-way valve (VR4),enum [cooling & defrost\|heating & dhw], ,false,sensor.boiler_4-way_valve_(VR4),sensor.boiler_hp4way Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpin1opt,input 1 options,string, ,true,sensor.boiler_input_1_options,sensor.boiler_hpin1opt Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpin2opt,input 2 options,string, ,true,sensor.boiler_input_2_options,sensor.boiler_hpin2opt @@ -2081,190 +2185,192 @@ Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,bo Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpin4opt,input 4 options,string, ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maxheatcomp,heat limit compressor,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maxheatheat,heat limit heating,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maxheatdhw,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit,select.boiler_maxheatdhw +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maxheatdhw,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_dhw_heat_limit,select.boiler_dhw_maxheatdhw Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,mandefrost,manual defrost,boolean, ,true,switch.boiler_manual_defrost,switch.boiler_mandefrost Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pvcooling,cooling only with PV,boolean, ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxheateronly,aux heater only,boolean, ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxheateroff,disable aux heater,boolean, ,true,switch.boiler_disable_aux_heater,switch.boiler_auxheateroff -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxheaterstatus,aux heater status,boolean, ,false,binary_sensor.boiler_aux_heater_status,binary_sensor.boiler_auxheaterstatus -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxheaterdelay,aux heater on delay,ushort (>=10<=1000),K*min,true,number.boiler_aux_heater_on_delay,number.boiler_auxheaterdelay -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxmaxlimit,aux heater max limit,uint (>=0<=10),K,true,number.boiler_aux_heater_max_limit,number.boiler_auxmaxlimit -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxlimitstart,aux heater limit start,uint (>=0<=10),K,true,number.boiler_aux_heater_limit_start,number.boiler_auxlimitstart +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxheaterstatus,aux heater status,uint8 (>=0<=100),%,false,sensor.boiler_aux_heater_status,sensor.boiler_auxheaterstatus +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxheaterdelay,aux heater on delay,uint16 (>=10<=1000),K*min,true,number.boiler_aux_heater_on_delay,number.boiler_auxheaterdelay +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxmaxlimit,aux heater max limit,uint8 (>=0<=10),K,true,number.boiler_aux_heater_max_limit,number.boiler_auxmaxlimit +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxlimitstart,aux heater limit start,uint8 (>=0<=10),K,true,number.boiler_aux_heater_limit_start,number.boiler_auxlimitstart Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxheatrmode,aux heater mode,enum [eco\|comfort], ,true,select.boiler_aux_heater_mode,select.boiler_auxheatrmode -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hphystheat,on/off hyst heat,ushort (>=50<=1500),K*min,true,number.boiler_on/off_hyst_heat,number.boiler_hphystheat -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hphystcool,on/off hyst cool,ushort (>=50<=1500),K*min,true,number.boiler_on/off_hyst_cool,number.boiler_hphystcool -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hphystpool,on/off hyst pool,ushort (>=50<=1500),K*min,true,number.boiler_on/off_hyst_pool,number.boiler_hphystpool +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hphystheat,on/off hyst heat,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_heat,number.boiler_hphystheat +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hphystcool,on/off hyst cool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_cool,number.boiler_hphystcool +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hphystpool,on/off hyst pool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_pool,number.boiler_hphystpool Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,silentmode,silent mode,enum [off\|auto\|on], ,true,select.boiler_silent_mode,select.boiler_silentmode -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,silentfrom,silent mode from,uint (>=0<=3810),minutes,true,number.boiler_silent_mode_from,number.boiler_silentfrom -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,silentto,silent mode to,uint (>=0<=3810),minutes,true,number.boiler_silent_mode_to,number.boiler_silentto -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,mintempsilent,min outside temp for silent mode,int (>=-126<=126),C,true,number.boiler_min_outside_temp_for_silent_mode,number.boiler_mintempsilent -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,tempparmode,outside temp parallel mode,int (>=-126<=126),C,true,number.boiler_outside_temp_parallel_mode,number.boiler_tempparmode -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxheatmix,aux heater mixing valve,int (>=-100<=100),%,false,sensor.boiler_aux_heater_mixing_valve,sensor.boiler_auxheatmix -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,tempdiffheat,temp diff TC3/TC0 heat,uint (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_heat,number.boiler_tempdiffheat -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,tempdiffcool,temp diff TC3/TC0 cool,uint (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_cool,number.boiler_tempdiffcool +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,silentfrom,silent mode from,uint8 (>=0<=3810),minutes,true,number.boiler_silent_mode_from,number.boiler_silentfrom +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,silentto,silent mode to,uint8 (>=0<=3810),minutes,true,number.boiler_silent_mode_to,number.boiler_silentto +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,mintempsilent,min outside temp for silent mode,int8 (>=-126<=126),C,true,number.boiler_min_outside_temp_for_silent_mode,number.boiler_mintempsilent +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,tempparmode,outside temp parallel mode,int8 (>=-126<=126),C,true,number.boiler_outside_temp_parallel_mode,number.boiler_tempparmode +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxheatmix,aux heater mixing valve,int8 (>=-100<=100),%,false,sensor.boiler_aux_heater_mixing_valve,sensor.boiler_auxheatmix +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,tempdiffheat,temp diff TC3/TC0 heat,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_heat,number.boiler_tempdiffheat +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,tempdiffcool,temp diff TC3/TC0 cool,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_cool,number.boiler_tempdiffcool Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,vpcooling,valve/pump cooling,boolean, ,true,switch.boiler_valve/pump_cooling,switch.boiler_vpcooling Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatcable,heating cable,boolean, ,true,switch.boiler_heating_cable,switch.boiler_heatcable Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,vc0valve,VC0 valve,boolean, ,true,switch.boiler_VC0_valve,switch.boiler_vc0valve Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,primepump,primary heatpump,boolean, ,true,switch.boiler_primary_heatpump,switch.boiler_primepump -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,primepumpmod,primary heatpump modulation,uint (>=0<=100),%,true,number.boiler_primary_heatpump_modulation,number.boiler_primepumpmod +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,primepumpmod,primary heatpump modulation,uint8 (>=0<=100),%,true,number.boiler_primary_heatpump_modulation,number.boiler_primepumpmod Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hp3way,3-way valve,boolean, ,true,switch.boiler_3-way_valve,switch.boiler_hp3way Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,elheatstep1,el. heater step 1,boolean, ,true,switch.boiler_el._heater_step_1,switch.boiler_elheatstep1 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,elheatstep2,el. heater step 2,boolean, ,true,switch.boiler_el._heater_step_2,switch.boiler_elheatstep2 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,elheatstep3,el. heater step 3,boolean, ,true,switch.boiler_el._heater_step_3,switch.boiler_elheatstep3 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpea0,condensate reservoir heating (EA0),boolean, ,false,binary_sensor.boiler_condensate_reservoir_heating_(EA0),binary_sensor.boiler_hpea0 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hppumpmode,primary heatpump mode,enum [auto\|continuous], ,true,select.boiler_primary_heatpump_mode,select.boiler_hppumpmode -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwalternatingop,alternating operation,boolean, ,true,switch.boiler_alternating_operation,switch.boiler_wwalternatingop -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwaltopprioheat,prioritise heating during dhw,uint (>=20<=120),minutes,true,number.boiler_prioritise_heating_during_dhw,number.boiler_wwaltopprioheat -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwaltopprioww,prioritise dhw during heating,uint (>=30<=120),minutes,true,number.boiler_prioritise_dhw_during_heating,number.boiler_wwaltopprioww -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwcomfoff,comfort switch off,uint (>=15<=65),C,true,number.boiler_comfort_switch_off,number.boiler_wwcomfoff -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwecooff,eco switch off,uint (>=15<=65),C,true,number.boiler_eco_switch_off,number.boiler_wwecooff -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwecoplusoff,eco+ switch off,uint (>=48<=63),C,true,number.boiler_eco+_switch_off,number.boiler_wwecoplusoff -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwcomfdiff,comfort diff,uint (>=6<=12),K,true,number.boiler_comfort_diff,number.boiler_wwcomfdiff -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwecodiff,eco diff,uint (>=6<=12),K,true,number.boiler_eco_diff,number.boiler_wwecodiff -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwecoplusdiff,eco+ diff,uint (>=6<=12),K,true,number.boiler_eco+_diff,number.boiler_wwecoplusdiff -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwcomfstop,comfort stop temp,uint (>=0<=254),C,true,number.boiler_comfort_stop_temp,number.boiler_wwcomfstop -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwecostop,eco stop temp,uint (>=0<=254),C,true,number.boiler_eco_stop_temp,number.boiler_wwecostop -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwecoplusstop,eco+ stop temp,uint (>=0<=254),C,true,number.boiler_eco+_stop_temp,number.boiler_wwecoplusstop -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpcircpumpww,circulation pump available during dhw,boolean, ,true,switch.boiler_circulation_pump_available_during_dhw,switch.boiler_hpcircpumpww -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Geo 5xx,boiler,173,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,fan,fan,uint8 (>=20<=100),%,true,number.boiler_fan,number.boiler_fan +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,shutdown,shutdown,boolean, ,true,switch.boiler_shutdown,switch.boiler_shutdown +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,alternatingop,alternating operation,boolean, ,true,switch.boiler_dhw_alternating_operation,switch.boiler_dhw_alternatingop +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,altopprioheat,prioritise heating during dhw,uint8 (>=20<=120),minutes,true,number.boiler_dhw_prioritise_heating_during_dhw,number.boiler_dhw_altopprioheat +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,altoppriodhw,prioritise dhw during heating,uint8 (>=30<=120),minutes,true,number.boiler_dhw_prioritise_dhw_during_heating,number.boiler_dhw_altoppriodhw +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,comfoff,comfort switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_comfort_switch_off,number.boiler_dhw_comfoff +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,ecooff,eco switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_eco_switch_off,number.boiler_dhw_ecooff +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,ecoplusoff,eco+ switch off,uint8 (>=48<=63),C,true,number.boiler_dhw_eco+_switch_off,number.boiler_dhw_ecoplusoff +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,comfdiff,comfort diff,uint8 (>=6<=12),K,true,number.boiler_dhw_comfort_diff,number.boiler_dhw_comfdiff +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,ecodiff,eco diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco_diff,number.boiler_dhw_ecodiff +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,ecoplusdiff,eco+ diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco+_diff,number.boiler_dhw_ecoplusdiff +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,comfstop,comfort stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_comfort_stop_temp,number.boiler_dhw_comfstop +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,ecostop,eco stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco_stop_temp,number.boiler_dhw_ecostop +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,ecoplusstop,eco+ stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco+_stop_temp,number.boiler_dhw_ecoplusstop +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpcircpumpdhw,circulation pump available during dhw,boolean, ,true,switch.boiler_dhw_circulation_pump_available_during_dhw,switch.boiler_dhw_hpcircpumpdhw +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1 +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2 +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1 +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2 +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,setpumppower,set pump power,uint8 (>=0<=100),%,false,sensor.boiler_dhw_set_pump_power,sensor.boiler_dhw_setpumppower +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm +Geo 5xx,boiler,173,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Geo 5xx,boiler,173,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Geo 5xx,boiler,173,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Geo 5xx,boiler,173,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Geo 5xx,boiler,173,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp -Geo 5xx,boiler,173,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod -Geo 5xx,boiler,173,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp -Geo 5xx,boiler,173,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp -Geo 5xx,boiler,173,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp -Geo 5xx,boiler,173,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp -Geo 5xx,boiler,173,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress -Geo 5xx,boiler,173,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp -Geo 5xx,boiler,173,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp +Geo 5xx,boiler,173,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Geo 5xx,boiler,173,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod +Geo 5xx,boiler,173,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp +Geo 5xx,boiler,173,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp +Geo 5xx,boiler,173,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp +Geo 5xx,boiler,173,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp +Geo 5xx,boiler,173,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress +Geo 5xx,boiler,173,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Geo 5xx,boiler,173,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Geo 5xx,boiler,173,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Geo 5xx,boiler,173,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Geo 5xx,boiler,173,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Geo 5xx,boiler,173,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump -Geo 5xx,boiler,173,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax -Geo 5xx,boiler,173,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin +Geo 5xx,boiler,173,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax +Geo 5xx,boiler,173,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Geo 5xx,boiler,173,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Geo 5xx,boiler,173,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Geo 5xx,boiler,173,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp -Geo 5xx,boiler,173,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Geo 5xx,boiler,173,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow -Geo 5xx,boiler,173,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Geo 5xx,boiler,173,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Geo 5xx,boiler,173,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay +Geo 5xx,boiler,173,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp +Geo 5xx,boiler,173,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow +Geo 5xx,boiler,173,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow +Geo 5xx,boiler,173,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow +Geo 5xx,boiler,173,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Geo 5xx,boiler,173,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Geo 5xx,boiler,173,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Geo 5xx,boiler,173,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Geo 5xx,boiler,173,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Geo 5xx,boiler,173,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Geo 5xx,boiler,173,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Geo 5xx,boiler,173,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Geo 5xx,boiler,173,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode -Geo 5xx,boiler,173,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber +Geo 5xx,boiler,173,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Geo 5xx,boiler,173,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Geo 5xx,boiler,173,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance -Geo 5xx,boiler,173,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime +Geo 5xx,boiler,173,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Geo 5xx,boiler,173,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Geo 5xx,boiler,173,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops -Geo 5xx,boiler,173,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp -Geo 5xx,boiler,173,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal -Geo 5xx,boiler,173,nrgww,energy,ulong (>=0<=167772),kWh,false,sensor.boiler_energy,sensor.boiler_nrgww -Geo 5xx,boiler,173,nrgheat,energy heating,ulong (>=0<=167772),kWh,false,sensor.boiler_energy_heating,sensor.boiler_nrgheat -Geo 5xx,boiler,173,metertotal,meter total,ulong (>=0<=167772),kWh,false,sensor.boiler_meter_total,sensor.boiler_metertotal -Geo 5xx,boiler,173,metercomp,meter compressor,ulong (>=0<=167772),kWh,false,sensor.boiler_meter_compressor,sensor.boiler_metercomp -Geo 5xx,boiler,173,metereheat,meter e-heater,ulong (>=0<=167772),kWh,false,sensor.boiler_meter_e-heater,sensor.boiler_metereheat -Geo 5xx,boiler,173,meterheat,meter heating,ulong (>=0<=167772),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat -Geo 5xx,boiler,173,meterww,meter,ulong (>=0<=167772),kWh,false,sensor.boiler_meter,sensor.boiler_meterww +Geo 5xx,boiler,173,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp +Geo 5xx,boiler,173,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Geo 5xx,boiler,173,nrgdhw,energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_energy,sensor.boiler_dhw_nrgdhw +Geo 5xx,boiler,173,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_energy_heating,sensor.boiler_nrgheat +Geo 5xx,boiler,173,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_total,sensor.boiler_metertotal +Geo 5xx,boiler,173,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_compressor,sensor.boiler_metercomp +Geo 5xx,boiler,173,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_e-heater,sensor.boiler_metereheat +Geo 5xx,boiler,173,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat +Geo 5xx,boiler,173,meterdhw,meter,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw Geo 5xx,boiler,173,uptimetotal,heatpump total uptime,time (>=0<=279620),minutes,false,sensor.boiler_heatpump_total_uptime,sensor.boiler_uptimetotal Geo 5xx,boiler,173,uptimecontrol,total operating time heat,time (>=0<=279620),minutes,false,sensor.boiler_total_operating_time_heat,sensor.boiler_uptimecontrol Geo 5xx,boiler,173,uptimecompheating,operating time compressor heating,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_heating,sensor.boiler_uptimecompheating Geo 5xx,boiler,173,uptimecompcooling,operating time compressor cooling,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_cooling,sensor.boiler_uptimecompcooling -Geo 5xx,boiler,173,uptimecompww,operating time compressor,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor,sensor.boiler_uptimecompww +Geo 5xx,boiler,173,uptimecompdhw,operating time compressor,time (>=0<=279620),minutes,false,sensor.boiler_dhw_operating_time_compressor,sensor.boiler_dhw_uptimecompdhw Geo 5xx,boiler,173,uptimecomppool,operating time compressor pool,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_pool,sensor.boiler_uptimecomppool -Geo 5xx,boiler,173,totalcompstarts,total compressor control starts,ulong (>=0<=16777213), ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts -Geo 5xx,boiler,173,heatingstarts,heating control starts,ulong (>=0<=16777213), ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts -Geo 5xx,boiler,173,coolingstarts,cooling control starts,ulong (>=0<=16777213), ,false,sensor.boiler_cooling_control_starts,sensor.boiler_coolingstarts -Geo 5xx,boiler,173,wwstarts2,control starts2,ulong (>=0<=16777213), ,false,sensor.boiler_control_starts2,sensor.boiler_wwstarts2 -Geo 5xx,boiler,173,poolstarts,pool control starts,ulong (>=0<=16777213), ,false,sensor.boiler_pool_control_starts,sensor.boiler_poolstarts -Geo 5xx,boiler,173,nrgconstotal,total energy consumption,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal -Geo 5xx,boiler,173,nrgconscomptotal,total energy consumption compressor,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal -Geo 5xx,boiler,173,nrgconscompheating,energy consumption compressor heating,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating -Geo 5xx,boiler,173,nrgconscompww,energy consumption compressor,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor,sensor.boiler_nrgconscompww -Geo 5xx,boiler,173,nrgconscompcooling,energy consumption compressor cooling,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling -Geo 5xx,boiler,173,nrgconscomppool,energy consumption compressor pool,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool -Geo 5xx,boiler,173,auxelecheatnrgconstotal,total aux elec. heater energy consumption,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal -Geo 5xx,boiler,173,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,ulong (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating -Geo 5xx,boiler,173,auxelecheatnrgconsww,aux elec. heater energy consumption,ulong (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconsww -Geo 5xx,boiler,173,auxelecheatnrgconspool,aux elec. heater energy consumption pool,ulong (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool -Geo 5xx,boiler,173,nrgsupptotal,total energy supplied,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal -Geo 5xx,boiler,173,nrgsuppheating,total energy supplied heating,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating -Geo 5xx,boiler,173,nrgsuppww,total energy warm supplied,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_warm_supplied,sensor.boiler_nrgsuppww -Geo 5xx,boiler,173,nrgsuppcooling,total energy supplied cooling,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling -Geo 5xx,boiler,173,nrgsupppool,total energy supplied pool,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool -Geo 5xx,boiler,173,hppower,compressor power output,uint (>=0<=25),kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower -Geo 5xx,boiler,173,hpmaxpower,compressor max power,uint (>=0<=100),%,true,number.boiler_compressor_max_power,number.boiler_hpmaxpower -Geo 5xx,boiler,173,hpsetdiffpress,set differental pressure,uint (>=150<=750),mbar,true,number.boiler_set_differental_pressure,number.boiler_hpsetdiffpress +Geo 5xx,boiler,173,totalcompstarts,total compressor control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts +Geo 5xx,boiler,173,heatingstarts,heating control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts +Geo 5xx,boiler,173,coolingstarts,cooling control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_cooling_control_starts,sensor.boiler_coolingstarts +Geo 5xx,boiler,173,starts2,control starts2,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_control_starts2,sensor.boiler_dhw_starts2 +Geo 5xx,boiler,173,poolstarts,pool control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_pool_control_starts,sensor.boiler_poolstarts +Geo 5xx,boiler,173,nrgconstotal,total energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal +Geo 5xx,boiler,173,nrgconscomptotal,total energy consumption compressor,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal +Geo 5xx,boiler,173,nrgconscompheating,energy consumption compressor heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating +Geo 5xx,boiler,173,nrgconscompdhw,energy consumption compressor,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_energy_consumption_compressor,sensor.boiler_dhw_nrgconscompdhw +Geo 5xx,boiler,173,nrgconscompcooling,energy consumption compressor cooling,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling +Geo 5xx,boiler,173,nrgconscomppool,energy consumption compressor pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool +Geo 5xx,boiler,173,auxelecheatnrgconstotal,total aux elec. heater energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal +Geo 5xx,boiler,173,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating +Geo 5xx,boiler,173,auxelecheatnrgconsdhw,aux elec. heater energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_aux_elec._heater_energy_consumption,sensor.boiler_dhw_auxelecheatnrgconsdhw +Geo 5xx,boiler,173,auxelecheatnrgconspool,aux elec. heater energy consumption pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool +Geo 5xx,boiler,173,nrgsupptotal,total energy supplied,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal +Geo 5xx,boiler,173,nrgsuppheating,total energy supplied heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating +Geo 5xx,boiler,173,nrgsuppdhw,total energy warm supplied,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_total_energy_warm_supplied,sensor.boiler_dhw_nrgsuppdhw +Geo 5xx,boiler,173,nrgsuppcooling,total energy supplied cooling,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling +Geo 5xx,boiler,173,nrgsupppool,total energy supplied pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool +Geo 5xx,boiler,173,hppower,compressor power output,uint8 (>=0<=25),kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower +Geo 5xx,boiler,173,hpmaxpower,compressor max power,uint8 (>=0<=100),%,true,number.boiler_compressor_max_power,number.boiler_hpmaxpower +Geo 5xx,boiler,173,hpsetdiffpress,set differental pressure,uint8 (>=150<=750),mbar,true,number.boiler_set_differental_pressure,number.boiler_hpsetdiffpress Geo 5xx,boiler,173,hpcompon,hp compressor,boolean, ,false,binary_sensor.boiler_hp_compressor,binary_sensor.boiler_hpcompon Geo 5xx,boiler,173,hpactivity,compressor activity,enum [none\|heating\|cooling\|hot water\|pool\|unknown\|defrost], ,false,sensor.boiler_compressor_activity,sensor.boiler_hpactivity -Geo 5xx,boiler,173,hpbrinepumpspd,brine pump speed,uint (>=0<=100),%,false,sensor.boiler_brine_pump_speed,sensor.boiler_hpbrinepumpspd +Geo 5xx,boiler,173,hpbrinepumpspd,brine pump speed,uint8 (>=0<=100),%,false,sensor.boiler_brine_pump_speed,sensor.boiler_hpbrinepumpspd Geo 5xx,boiler,173,hpswitchvalve,switch valve,boolean, ,false,binary_sensor.boiler_switch_valve,binary_sensor.boiler_hpswitchvalve -Geo 5xx,boiler,173,hpcompspd,compressor speed,uint (>=0<=100),%,false,sensor.boiler_compressor_speed,sensor.boiler_hpcompspd -Geo 5xx,boiler,173,hpcircspd,circulation pump speed,uint (>=0<=100),%,false,sensor.boiler_circulation_pump_speed,sensor.boiler_hpcircspd -Geo 5xx,boiler,173,hpbrinein,brine in/evaporator,short (>=-3199<=3199),C,false,sensor.boiler_brine_in/evaporator,sensor.boiler_hpbrinein -Geo 5xx,boiler,173,hpbrineout,brine out/condenser,short (>=-3199<=3199),C,false,sensor.boiler_brine_out/condenser,sensor.boiler_hpbrineout -Geo 5xx,boiler,173,hptc0,heat carrier return (TC0),short (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_return_(TC0),sensor.boiler_hptc0 -Geo 5xx,boiler,173,hptc1,heat carrier forward (TC1),short (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_forward_(TC1),sensor.boiler_hptc1 -Geo 5xx,boiler,173,hptc3,condenser temperature (TC3),short (>=-3199<=3199),C,false,sensor.boiler_condenser_temperature_(TC3),sensor.boiler_hptc3 -Geo 5xx,boiler,173,hptr1,compressor temperature (TR1),short (>=-3199<=3199),C,false,sensor.boiler_compressor_temperature_(TR1),sensor.boiler_hptr1 -Geo 5xx,boiler,173,hptr3,refrigerant temperature liquid side (condenser output) (TR3),short (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.boiler_hptr3 -Geo 5xx,boiler,173,hptr4,evaporator inlet temperature (TR4),short (>=-3199<=3199),C,false,sensor.boiler_evaporator_inlet_temperature_(TR4),sensor.boiler_hptr4 -Geo 5xx,boiler,173,hptr5,compressor inlet temperature (TR5),short (>=-3199<=3199),C,false,sensor.boiler_compressor_inlet_temperature_(TR5),sensor.boiler_hptr5 -Geo 5xx,boiler,173,hptr6,compressor outlet temperature (TR6),short (>=-3199<=3199),C,false,sensor.boiler_compressor_outlet_temperature_(TR6),sensor.boiler_hptr6 -Geo 5xx,boiler,173,hptr7,refrigerant temperature gas side (condenser input) (TR7),short (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7),sensor.boiler_hptr7 -Geo 5xx,boiler,173,hptl2,air inlet temperature (TL2),short (>=-3199<=3199),C,false,sensor.boiler_air_inlet_temperature_(TL2),sensor.boiler_hptl2 -Geo 5xx,boiler,173,hppl1,low pressure side temperature (PL1),short (>=-3199<=3199),C,false,sensor.boiler_low_pressure_side_temperature_(PL1),sensor.boiler_hppl1 -Geo 5xx,boiler,173,hpph1,high pressure side temperature (PH1),short (>=-3199<=3199),C,false,sensor.boiler_high_pressure_side_temperature_(PH1),sensor.boiler_hpph1 -Geo 5xx,boiler,173,hpta4,drain pan temp (TA4),short (>=-3199<=3199),C,false,sensor.boiler_drain_pan_temp_(TA4),sensor.boiler_hpta4 -Geo 5xx,boiler,173,hptw1,reservoir temp (TW1),short (>=-3199<=3199),C,false,sensor.boiler_reservoir_temp_(TW1),sensor.boiler_hptw1 -Geo 5xx,boiler,173,poolsettemp,pool set temperature,uint (>=0<=127),C,true,number.boiler_pool_set_temperature,number.boiler_poolsettemp +Geo 5xx,boiler,173,hpcompspd,compressor speed,uint8 (>=0<=100),%,false,sensor.boiler_compressor_speed,sensor.boiler_hpcompspd +Geo 5xx,boiler,173,hpcircspd,circulation pump speed,uint8 (>=0<=100),%,false,sensor.boiler_circulation_pump_speed,sensor.boiler_hpcircspd +Geo 5xx,boiler,173,hpbrinein,brine in/evaporator,int16 (>=-3199<=3199),C,false,sensor.boiler_brine_in/evaporator,sensor.boiler_hpbrinein +Geo 5xx,boiler,173,hpbrineout,brine out/condenser,int16 (>=-3199<=3199),C,false,sensor.boiler_brine_out/condenser,sensor.boiler_hpbrineout +Geo 5xx,boiler,173,hptc0,heat carrier return (TC0),int16 (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_return_(TC0),sensor.boiler_hptc0 +Geo 5xx,boiler,173,hptc1,heat carrier forward (TC1),int16 (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_forward_(TC1),sensor.boiler_hptc1 +Geo 5xx,boiler,173,hptc3,condenser temperature (TC3),int16 (>=-3199<=3199),C,false,sensor.boiler_condenser_temperature_(TC3),sensor.boiler_hptc3 +Geo 5xx,boiler,173,hptr1,compressor temperature (TR1),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_temperature_(TR1),sensor.boiler_hptr1 +Geo 5xx,boiler,173,hptr3,refrigerant temperature liquid side (condenser output) (TR3),int16 (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.boiler_hptr3 +Geo 5xx,boiler,173,hptr4,evaporator inlet temperature (TR4),int16 (>=-3199<=3199),C,false,sensor.boiler_evaporator_inlet_temperature_(TR4),sensor.boiler_hptr4 +Geo 5xx,boiler,173,hptr5,compressor inlet temperature (TR5),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_inlet_temperature_(TR5),sensor.boiler_hptr5 +Geo 5xx,boiler,173,hptr6,compressor outlet temperature (TR6),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_outlet_temperature_(TR6),sensor.boiler_hptr6 +Geo 5xx,boiler,173,hptr7,refrigerant temperature gas side (condenser input) (TR7),int16 (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7),sensor.boiler_hptr7 +Geo 5xx,boiler,173,hptl2,air inlet temperature (TL2),int16 (>=-3199<=3199),C,false,sensor.boiler_air_inlet_temperature_(TL2),sensor.boiler_hptl2 +Geo 5xx,boiler,173,hppl1,low pressure side temperature (PL1),int16 (>=-3199<=3199),C,false,sensor.boiler_low_pressure_side_temperature_(PL1),sensor.boiler_hppl1 +Geo 5xx,boiler,173,hpph1,high pressure side temperature (PH1),int16 (>=-3199<=3199),C,false,sensor.boiler_high_pressure_side_temperature_(PH1),sensor.boiler_hpph1 +Geo 5xx,boiler,173,hpta4,drain pan temp (TA4),int16 (>=-3199<=3199),C,false,sensor.boiler_drain_pan_temp_(TA4),sensor.boiler_hpta4 +Geo 5xx,boiler,173,hptw1,reservoir temp (TW1),int16 (>=-3199<=3199),C,false,sensor.boiler_reservoir_temp_(TW1),sensor.boiler_hptw1 +Geo 5xx,boiler,173,poolsettemp,pool set temperature,uint8 (>=0<=127),C,true,number.boiler_pool_set_temperature,number.boiler_poolsettemp Geo 5xx,boiler,173,hp4way,4-way valve (VR4),enum [cooling & defrost\|heating & dhw], ,false,sensor.boiler_4-way_valve_(VR4),sensor.boiler_hp4way Geo 5xx,boiler,173,hpin1opt,input 1 options,string, ,true,sensor.boiler_input_1_options,sensor.boiler_hpin1opt Geo 5xx,boiler,173,hpin2opt,input 2 options,string, ,true,sensor.boiler_input_2_options,sensor.boiler_hpin2opt @@ -2272,985 +2378,1013 @@ Geo 5xx,boiler,173,hpin3opt,input 3 options,string, ,true,sensor.boiler_input_3_ Geo 5xx,boiler,173,hpin4opt,input 4 options,string, ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt Geo 5xx,boiler,173,maxheatcomp,heat limit compressor,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp Geo 5xx,boiler,173,maxheatheat,heat limit heating,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat -Geo 5xx,boiler,173,maxheatdhw,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit,select.boiler_maxheatdhw +Geo 5xx,boiler,173,maxheatdhw,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_dhw_heat_limit,select.boiler_dhw_maxheatdhw Geo 5xx,boiler,173,mandefrost,manual defrost,boolean, ,true,switch.boiler_manual_defrost,switch.boiler_mandefrost Geo 5xx,boiler,173,pvcooling,cooling only with PV,boolean, ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling Geo 5xx,boiler,173,auxheateronly,aux heater only,boolean, ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly Geo 5xx,boiler,173,auxheateroff,disable aux heater,boolean, ,true,switch.boiler_disable_aux_heater,switch.boiler_auxheateroff -Geo 5xx,boiler,173,auxheaterstatus,aux heater status,boolean, ,false,binary_sensor.boiler_aux_heater_status,binary_sensor.boiler_auxheaterstatus -Geo 5xx,boiler,173,auxheaterdelay,aux heater on delay,ushort (>=10<=1000),K*min,true,number.boiler_aux_heater_on_delay,number.boiler_auxheaterdelay -Geo 5xx,boiler,173,auxmaxlimit,aux heater max limit,uint (>=0<=10),K,true,number.boiler_aux_heater_max_limit,number.boiler_auxmaxlimit -Geo 5xx,boiler,173,auxlimitstart,aux heater limit start,uint (>=0<=10),K,true,number.boiler_aux_heater_limit_start,number.boiler_auxlimitstart +Geo 5xx,boiler,173,auxheaterstatus,aux heater status,uint8 (>=0<=100),%,false,sensor.boiler_aux_heater_status,sensor.boiler_auxheaterstatus +Geo 5xx,boiler,173,auxheaterdelay,aux heater on delay,uint16 (>=10<=1000),K*min,true,number.boiler_aux_heater_on_delay,number.boiler_auxheaterdelay +Geo 5xx,boiler,173,auxmaxlimit,aux heater max limit,uint8 (>=0<=10),K,true,number.boiler_aux_heater_max_limit,number.boiler_auxmaxlimit +Geo 5xx,boiler,173,auxlimitstart,aux heater limit start,uint8 (>=0<=10),K,true,number.boiler_aux_heater_limit_start,number.boiler_auxlimitstart Geo 5xx,boiler,173,auxheatrmode,aux heater mode,enum [eco\|comfort], ,true,select.boiler_aux_heater_mode,select.boiler_auxheatrmode -Geo 5xx,boiler,173,hphystheat,on/off hyst heat,ushort (>=50<=1500),K*min,true,number.boiler_on/off_hyst_heat,number.boiler_hphystheat -Geo 5xx,boiler,173,hphystcool,on/off hyst cool,ushort (>=50<=1500),K*min,true,number.boiler_on/off_hyst_cool,number.boiler_hphystcool -Geo 5xx,boiler,173,hphystpool,on/off hyst pool,ushort (>=50<=1500),K*min,true,number.boiler_on/off_hyst_pool,number.boiler_hphystpool +Geo 5xx,boiler,173,hphystheat,on/off hyst heat,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_heat,number.boiler_hphystheat +Geo 5xx,boiler,173,hphystcool,on/off hyst cool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_cool,number.boiler_hphystcool +Geo 5xx,boiler,173,hphystpool,on/off hyst pool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_pool,number.boiler_hphystpool Geo 5xx,boiler,173,silentmode,silent mode,enum [off\|auto\|on], ,true,select.boiler_silent_mode,select.boiler_silentmode -Geo 5xx,boiler,173,silentfrom,silent mode from,uint (>=0<=3810),minutes,true,number.boiler_silent_mode_from,number.boiler_silentfrom -Geo 5xx,boiler,173,silentto,silent mode to,uint (>=0<=3810),minutes,true,number.boiler_silent_mode_to,number.boiler_silentto -Geo 5xx,boiler,173,mintempsilent,min outside temp for silent mode,int (>=-126<=126),C,true,number.boiler_min_outside_temp_for_silent_mode,number.boiler_mintempsilent -Geo 5xx,boiler,173,tempparmode,outside temp parallel mode,int (>=-126<=126),C,true,number.boiler_outside_temp_parallel_mode,number.boiler_tempparmode -Geo 5xx,boiler,173,auxheatmix,aux heater mixing valve,int (>=-100<=100),%,false,sensor.boiler_aux_heater_mixing_valve,sensor.boiler_auxheatmix -Geo 5xx,boiler,173,tempdiffheat,temp diff TC3/TC0 heat,uint (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_heat,number.boiler_tempdiffheat -Geo 5xx,boiler,173,tempdiffcool,temp diff TC3/TC0 cool,uint (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_cool,number.boiler_tempdiffcool +Geo 5xx,boiler,173,silentfrom,silent mode from,uint8 (>=0<=3810),minutes,true,number.boiler_silent_mode_from,number.boiler_silentfrom +Geo 5xx,boiler,173,silentto,silent mode to,uint8 (>=0<=3810),minutes,true,number.boiler_silent_mode_to,number.boiler_silentto +Geo 5xx,boiler,173,mintempsilent,min outside temp for silent mode,int8 (>=-126<=126),C,true,number.boiler_min_outside_temp_for_silent_mode,number.boiler_mintempsilent +Geo 5xx,boiler,173,tempparmode,outside temp parallel mode,int8 (>=-126<=126),C,true,number.boiler_outside_temp_parallel_mode,number.boiler_tempparmode +Geo 5xx,boiler,173,auxheatmix,aux heater mixing valve,int8 (>=-100<=100),%,false,sensor.boiler_aux_heater_mixing_valve,sensor.boiler_auxheatmix +Geo 5xx,boiler,173,tempdiffheat,temp diff TC3/TC0 heat,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_heat,number.boiler_tempdiffheat +Geo 5xx,boiler,173,tempdiffcool,temp diff TC3/TC0 cool,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_cool,number.boiler_tempdiffcool Geo 5xx,boiler,173,vpcooling,valve/pump cooling,boolean, ,true,switch.boiler_valve/pump_cooling,switch.boiler_vpcooling Geo 5xx,boiler,173,heatcable,heating cable,boolean, ,true,switch.boiler_heating_cable,switch.boiler_heatcable Geo 5xx,boiler,173,vc0valve,VC0 valve,boolean, ,true,switch.boiler_VC0_valve,switch.boiler_vc0valve Geo 5xx,boiler,173,primepump,primary heatpump,boolean, ,true,switch.boiler_primary_heatpump,switch.boiler_primepump -Geo 5xx,boiler,173,primepumpmod,primary heatpump modulation,uint (>=0<=100),%,true,number.boiler_primary_heatpump_modulation,number.boiler_primepumpmod +Geo 5xx,boiler,173,primepumpmod,primary heatpump modulation,uint8 (>=0<=100),%,true,number.boiler_primary_heatpump_modulation,number.boiler_primepumpmod Geo 5xx,boiler,173,hp3way,3-way valve,boolean, ,true,switch.boiler_3-way_valve,switch.boiler_hp3way Geo 5xx,boiler,173,elheatstep1,el. heater step 1,boolean, ,true,switch.boiler_el._heater_step_1,switch.boiler_elheatstep1 Geo 5xx,boiler,173,elheatstep2,el. heater step 2,boolean, ,true,switch.boiler_el._heater_step_2,switch.boiler_elheatstep2 Geo 5xx,boiler,173,elheatstep3,el. heater step 3,boolean, ,true,switch.boiler_el._heater_step_3,switch.boiler_elheatstep3 Geo 5xx,boiler,173,hpea0,condensate reservoir heating (EA0),boolean, ,false,binary_sensor.boiler_condensate_reservoir_heating_(EA0),binary_sensor.boiler_hpea0 Geo 5xx,boiler,173,hppumpmode,primary heatpump mode,enum [auto\|continuous], ,true,select.boiler_primary_heatpump_mode,select.boiler_hppumpmode -Geo 5xx,boiler,173,wwalternatingop,alternating operation,boolean, ,true,switch.boiler_alternating_operation,switch.boiler_wwalternatingop -Geo 5xx,boiler,173,wwaltopprioheat,prioritise heating during dhw,uint (>=20<=120),minutes,true,number.boiler_prioritise_heating_during_dhw,number.boiler_wwaltopprioheat -Geo 5xx,boiler,173,wwaltopprioww,prioritise dhw during heating,uint (>=30<=120),minutes,true,number.boiler_prioritise_dhw_during_heating,number.boiler_wwaltopprioww -Geo 5xx,boiler,173,wwcomfoff,comfort switch off,uint (>=15<=65),C,true,number.boiler_comfort_switch_off,number.boiler_wwcomfoff -Geo 5xx,boiler,173,wwecooff,eco switch off,uint (>=15<=65),C,true,number.boiler_eco_switch_off,number.boiler_wwecooff -Geo 5xx,boiler,173,wwecoplusoff,eco+ switch off,uint (>=48<=63),C,true,number.boiler_eco+_switch_off,number.boiler_wwecoplusoff -Geo 5xx,boiler,173,wwcomfdiff,comfort diff,uint (>=6<=12),K,true,number.boiler_comfort_diff,number.boiler_wwcomfdiff -Geo 5xx,boiler,173,wwecodiff,eco diff,uint (>=6<=12),K,true,number.boiler_eco_diff,number.boiler_wwecodiff -Geo 5xx,boiler,173,wwecoplusdiff,eco+ diff,uint (>=6<=12),K,true,number.boiler_eco+_diff,number.boiler_wwecoplusdiff -Geo 5xx,boiler,173,wwcomfstop,comfort stop temp,uint (>=0<=254),C,true,number.boiler_comfort_stop_temp,number.boiler_wwcomfstop -Geo 5xx,boiler,173,wwecostop,eco stop temp,uint (>=0<=254),C,true,number.boiler_eco_stop_temp,number.boiler_wwecostop -Geo 5xx,boiler,173,wwecoplusstop,eco+ stop temp,uint (>=0<=254),C,true,number.boiler_eco+_stop_temp,number.boiler_wwecoplusstop -Geo 5xx,boiler,173,hpcircpumpww,circulation pump available during dhw,boolean, ,true,switch.boiler_circulation_pump_available_during_dhw,switch.boiler_hpcircpumpww -Geo 5xx,boiler,173,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated -Geo 5xx,boiler,173,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp -Geo 5xx,boiler,173,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp -Geo 5xx,boiler,173,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow -Geo 5xx,boiler,173,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus -Geo 5xx,boiler,173,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff -Geo 5xx,boiler,173,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle -Geo 5xx,boiler,173,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp -Geo 5xx,boiler,173,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype -Geo 5xx,boiler,173,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort -Geo 5xx,boiler,173,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 -Geo 5xx,boiler,173,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset -Geo 5xx,boiler,173,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization -Geo 5xx,boiler,173,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Geo 5xx,boiler,173,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp -Geo 5xx,boiler,173,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump -Geo 5xx,boiler,173,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype -Geo 5xx,boiler,173,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston -Geo 5xx,boiler,173,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Geo 5xx,boiler,173,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp -Geo 5xx,boiler,173,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode -Geo 5xx,boiler,173,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc -Geo 5xx,boiler,173,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp -Geo 5xx,boiler,173,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 -Geo 5xx,boiler,173,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow -Geo 5xx,boiler,173,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 -Geo 5xx,boiler,173,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 -Geo 5xx,boiler,173,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated -Geo 5xx,boiler,173,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime -Geo 5xx,boiler,173,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting -Geo 5xx,boiler,173,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging -Geo 5xx,boiler,173,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging -Geo 5xx,boiler,173,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok -Geo 5xx,boiler,173,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive -Geo 5xx,boiler,173,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve -Geo 5xx,boiler,173,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower -Geo 5xx,boiler,173,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp -Geo 5xx,boiler,173,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Geo 5xx,boiler,173,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Geo 5xx,boiler,173,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Geo 5xx,boiler,173,fan,fan,uint8 (>=20<=100),%,true,number.boiler_fan,number.boiler_fan +Geo 5xx,boiler,173,shutdown,shutdown,boolean, ,true,switch.boiler_shutdown,switch.boiler_shutdown +Geo 5xx,boiler,173,alternatingop,alternating operation,boolean, ,true,switch.boiler_dhw_alternating_operation,switch.boiler_dhw_alternatingop +Geo 5xx,boiler,173,altopprioheat,prioritise heating during dhw,uint8 (>=20<=120),minutes,true,number.boiler_dhw_prioritise_heating_during_dhw,number.boiler_dhw_altopprioheat +Geo 5xx,boiler,173,altoppriodhw,prioritise dhw during heating,uint8 (>=30<=120),minutes,true,number.boiler_dhw_prioritise_dhw_during_heating,number.boiler_dhw_altoppriodhw +Geo 5xx,boiler,173,comfoff,comfort switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_comfort_switch_off,number.boiler_dhw_comfoff +Geo 5xx,boiler,173,ecooff,eco switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_eco_switch_off,number.boiler_dhw_ecooff +Geo 5xx,boiler,173,ecoplusoff,eco+ switch off,uint8 (>=48<=63),C,true,number.boiler_dhw_eco+_switch_off,number.boiler_dhw_ecoplusoff +Geo 5xx,boiler,173,comfdiff,comfort diff,uint8 (>=6<=12),K,true,number.boiler_dhw_comfort_diff,number.boiler_dhw_comfdiff +Geo 5xx,boiler,173,ecodiff,eco diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco_diff,number.boiler_dhw_ecodiff +Geo 5xx,boiler,173,ecoplusdiff,eco+ diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco+_diff,number.boiler_dhw_ecoplusdiff +Geo 5xx,boiler,173,comfstop,comfort stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_comfort_stop_temp,number.boiler_dhw_comfstop +Geo 5xx,boiler,173,ecostop,eco stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco_stop_temp,number.boiler_dhw_ecostop +Geo 5xx,boiler,173,ecoplusstop,eco+ stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco+_stop_temp,number.boiler_dhw_ecoplusstop +Geo 5xx,boiler,173,hpcircpumpdhw,circulation pump available during dhw,boolean, ,true,switch.boiler_dhw_circulation_pump_available_during_dhw,switch.boiler_dhw_hpcircpumpdhw +Geo 5xx,boiler,173,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated +Geo 5xx,boiler,173,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp +Geo 5xx,boiler,173,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp +Geo 5xx,boiler,173,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow +Geo 5xx,boiler,173,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus +Geo 5xx,boiler,173,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff +Geo 5xx,boiler,173,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle +Geo 5xx,boiler,173,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp +Geo 5xx,boiler,173,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type +Geo 5xx,boiler,173,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort +Geo 5xx,boiler,173,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1 +Geo 5xx,boiler,173,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset +Geo 5xx,boiler,173,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization +Geo 5xx,boiler,173,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower +Geo 5xx,boiler,173,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp +Geo 5xx,boiler,173,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump +Geo 5xx,boiler,173,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype +Geo 5xx,boiler,173,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston +Geo 5xx,boiler,173,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff +Geo 5xx,boiler,173,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp +Geo 5xx,boiler,173,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode +Geo 5xx,boiler,173,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ +Geo 5xx,boiler,173,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp +Geo 5xx,boiler,173,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2 +Geo 5xx,boiler,173,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow +Geo 5xx,boiler,173,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1 +Geo 5xx,boiler,173,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2 +Geo 5xx,boiler,173,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated +Geo 5xx,boiler,173,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime +Geo 5xx,boiler,173,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting +Geo 5xx,boiler,173,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging +Geo 5xx,boiler,173,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging +Geo 5xx,boiler,173,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok +Geo 5xx,boiler,173,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active +Geo 5xx,boiler,173,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve +Geo 5xx,boiler,173,setpumppower,set pump power,uint8 (>=0<=100),%,false,sensor.boiler_dhw_set_pump_power,sensor.boiler_dhw_setpumppower +Geo 5xx,boiler,173,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp +Geo 5xx,boiler,173,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp +Geo 5xx,boiler,173,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts +Geo 5xx,boiler,173,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww -Logamax U122/Cerapur,boiler,203,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1 +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2 +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1 +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2 +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,setpumppower,set pump power,uint8 (>=0<=100),%,false,sensor.boiler_dhw_set_pump_power,sensor.boiler_dhw_setpumppower +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Logamax U122/Cerapur,boiler,203,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Logamax U122/Cerapur,boiler,203,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Logamax U122/Cerapur,boiler,203,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Logamax U122/Cerapur,boiler,203,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Logamax U122/Cerapur,boiler,203,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp -Logamax U122/Cerapur,boiler,203,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod -Logamax U122/Cerapur,boiler,203,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp -Logamax U122/Cerapur,boiler,203,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp -Logamax U122/Cerapur,boiler,203,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp -Logamax U122/Cerapur,boiler,203,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp -Logamax U122/Cerapur,boiler,203,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress -Logamax U122/Cerapur,boiler,203,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp -Logamax U122/Cerapur,boiler,203,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp -Logamax U122/Cerapur,boiler,203,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp +Logamax U122/Cerapur,boiler,203,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Logamax U122/Cerapur,boiler,203,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod +Logamax U122/Cerapur,boiler,203,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp +Logamax U122/Cerapur,boiler,203,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp +Logamax U122/Cerapur,boiler,203,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp +Logamax U122/Cerapur,boiler,203,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp +Logamax U122/Cerapur,boiler,203,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress +Logamax U122/Cerapur,boiler,203,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Logamax U122/Cerapur,boiler,203,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp +Logamax U122/Cerapur,boiler,203,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Logamax U122/Cerapur,boiler,203,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Logamax U122/Cerapur,boiler,203,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 -Logamax U122/Cerapur,boiler,203,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr +Logamax U122/Cerapur,boiler,203,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Logamax U122/Cerapur,boiler,203,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Logamax U122/Cerapur,boiler,203,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Logamax U122/Cerapur,boiler,203,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat -Logamax U122/Cerapur,boiler,203,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Logamax U122/Cerapur,boiler,203,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Logamax U122/Cerapur,boiler,203,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Logamax U122/Cerapur,boiler,203,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow -Logamax U122/Cerapur,boiler,203,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock -Logamax U122/Cerapur,boiler,203,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Logamax U122/Cerapur,boiler,203,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Logamax U122/Cerapur,boiler,203,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Logamax U122/Cerapur,boiler,203,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Logamax U122/Cerapur,boiler,203,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Logamax U122/Cerapur,boiler,203,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Logamax U122/Cerapur,boiler,203,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Logamax U122/Cerapur,boiler,203,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Logamax U122/Cerapur,boiler,203,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Logamax U122/Cerapur,boiler,203,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Logamax U122/Cerapur,boiler,203,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff +Logamax U122/Cerapur,boiler,203,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston +Logamax U122/Cerapur,boiler,203,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Logamax U122/Cerapur,boiler,203,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon -Logamax U122/Cerapur,boiler,203,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase -Logamax U122/Cerapur,boiler,203,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Logamax U122/Cerapur,boiler,203,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Logamax U122/Cerapur,boiler,203,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase +Logamax U122/Cerapur,boiler,203,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend +Logamax U122/Cerapur,boiler,203,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Logamax U122/Cerapur,boiler,203,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode -Logamax U122/Cerapur,boiler,203,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp +Logamax U122/Cerapur,boiler,203,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Logamax U122/Cerapur,boiler,203,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Logamax U122/Cerapur,boiler,203,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Logamax U122/Cerapur,boiler,203,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Logamax U122/Cerapur,boiler,203,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump -Logamax U122/Cerapur,boiler,203,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax -Logamax U122/Cerapur,boiler,203,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin +Logamax U122/Cerapur,boiler,203,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax +Logamax U122/Cerapur,boiler,203,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Logamax U122/Cerapur,boiler,203,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Logamax U122/Cerapur,boiler,203,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Logamax U122/Cerapur,boiler,203,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp -Logamax U122/Cerapur,boiler,203,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Logamax U122/Cerapur,boiler,203,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow -Logamax U122/Cerapur,boiler,203,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Logamax U122/Cerapur,boiler,203,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Logamax U122/Cerapur,boiler,203,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay +Logamax U122/Cerapur,boiler,203,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp +Logamax U122/Cerapur,boiler,203,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow +Logamax U122/Cerapur,boiler,203,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow +Logamax U122/Cerapur,boiler,203,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow +Logamax U122/Cerapur,boiler,203,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Logamax U122/Cerapur,boiler,203,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Logamax U122/Cerapur,boiler,203,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Logamax U122/Cerapur,boiler,203,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Logamax U122/Cerapur,boiler,203,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Logamax U122/Cerapur,boiler,203,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Logamax U122/Cerapur,boiler,203,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Logamax U122/Cerapur,boiler,203,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Logamax U122/Cerapur,boiler,203,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode -Logamax U122/Cerapur,boiler,203,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber +Logamax U122/Cerapur,boiler,203,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Logamax U122/Cerapur,boiler,203,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Logamax U122/Cerapur,boiler,203,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance -Logamax U122/Cerapur,boiler,203,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime +Logamax U122/Cerapur,boiler,203,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Logamax U122/Cerapur,boiler,203,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Logamax U122/Cerapur,boiler,203,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops -Logamax U122/Cerapur,boiler,203,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp -Logamax U122/Cerapur,boiler,203,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated -Logamax U122/Cerapur,boiler,203,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp -Logamax U122/Cerapur,boiler,203,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp -Logamax U122/Cerapur,boiler,203,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow -Logamax U122/Cerapur,boiler,203,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus -Logamax U122/Cerapur,boiler,203,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff -Logamax U122/Cerapur,boiler,203,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle -Logamax U122/Cerapur,boiler,203,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp -Logamax U122/Cerapur,boiler,203,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype -Logamax U122/Cerapur,boiler,203,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort -Logamax U122/Cerapur,boiler,203,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 -Logamax U122/Cerapur,boiler,203,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset -Logamax U122/Cerapur,boiler,203,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization -Logamax U122/Cerapur,boiler,203,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Logamax U122/Cerapur,boiler,203,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp -Logamax U122/Cerapur,boiler,203,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump -Logamax U122/Cerapur,boiler,203,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype -Logamax U122/Cerapur,boiler,203,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston -Logamax U122/Cerapur,boiler,203,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Logamax U122/Cerapur,boiler,203,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp -Logamax U122/Cerapur,boiler,203,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode -Logamax U122/Cerapur,boiler,203,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc -Logamax U122/Cerapur,boiler,203,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp -Logamax U122/Cerapur,boiler,203,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 -Logamax U122/Cerapur,boiler,203,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow -Logamax U122/Cerapur,boiler,203,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 -Logamax U122/Cerapur,boiler,203,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 -Logamax U122/Cerapur,boiler,203,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated -Logamax U122/Cerapur,boiler,203,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime -Logamax U122/Cerapur,boiler,203,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting -Logamax U122/Cerapur,boiler,203,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging -Logamax U122/Cerapur,boiler,203,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging -Logamax U122/Cerapur,boiler,203,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok -Logamax U122/Cerapur,boiler,203,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive -Logamax U122/Cerapur,boiler,203,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve -Logamax U122/Cerapur,boiler,203,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower -Logamax U122/Cerapur,boiler,203,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp -Logamax U122/Cerapur,boiler,203,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Logamax U122/Cerapur,boiler,203,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Logamax U122/Cerapur,boiler,203,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Logamax U122/Cerapur,boiler,203,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower -Logamax U122/Cerapur,boiler,203,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal -Logamax U122/Cerapur,boiler,203,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Logamax U122/Cerapur,boiler,203,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww -Ecomline Excellent,boiler,206,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Logamax U122/Cerapur,boiler,203,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp +Logamax U122/Cerapur,boiler,203,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat +Logamax U122/Cerapur,boiler,203,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Logamax U122/Cerapur,boiler,203,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat +Logamax U122/Cerapur,boiler,203,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Logamax U122/Cerapur,boiler,203,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 +Logamax U122/Cerapur,boiler,203,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Logamax U122/Cerapur,boiler,203,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated +Logamax U122/Cerapur,boiler,203,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp +Logamax U122/Cerapur,boiler,203,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp +Logamax U122/Cerapur,boiler,203,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow +Logamax U122/Cerapur,boiler,203,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus +Logamax U122/Cerapur,boiler,203,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff +Logamax U122/Cerapur,boiler,203,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle +Logamax U122/Cerapur,boiler,203,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp +Logamax U122/Cerapur,boiler,203,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type +Logamax U122/Cerapur,boiler,203,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort +Logamax U122/Cerapur,boiler,203,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1 +Logamax U122/Cerapur,boiler,203,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset +Logamax U122/Cerapur,boiler,203,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization +Logamax U122/Cerapur,boiler,203,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower +Logamax U122/Cerapur,boiler,203,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp +Logamax U122/Cerapur,boiler,203,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump +Logamax U122/Cerapur,boiler,203,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype +Logamax U122/Cerapur,boiler,203,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston +Logamax U122/Cerapur,boiler,203,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff +Logamax U122/Cerapur,boiler,203,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp +Logamax U122/Cerapur,boiler,203,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode +Logamax U122/Cerapur,boiler,203,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ +Logamax U122/Cerapur,boiler,203,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp +Logamax U122/Cerapur,boiler,203,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2 +Logamax U122/Cerapur,boiler,203,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow +Logamax U122/Cerapur,boiler,203,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1 +Logamax U122/Cerapur,boiler,203,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2 +Logamax U122/Cerapur,boiler,203,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated +Logamax U122/Cerapur,boiler,203,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime +Logamax U122/Cerapur,boiler,203,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting +Logamax U122/Cerapur,boiler,203,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging +Logamax U122/Cerapur,boiler,203,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging +Logamax U122/Cerapur,boiler,203,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok +Logamax U122/Cerapur,boiler,203,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active +Logamax U122/Cerapur,boiler,203,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve +Logamax U122/Cerapur,boiler,203,setpumppower,set pump power,uint8 (>=0<=100),%,false,sensor.boiler_dhw_set_pump_power,sensor.boiler_dhw_setpumppower +Logamax U122/Cerapur,boiler,203,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp +Logamax U122/Cerapur,boiler,203,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp +Logamax U122/Cerapur,boiler,203,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts +Logamax U122/Cerapur,boiler,203,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm +Logamax U122/Cerapur,boiler,203,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Logamax U122/Cerapur,boiler,203,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Logamax U122/Cerapur,boiler,203,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Logamax U122/Cerapur,boiler,203,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Ecomline Excellent,boiler,206,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Ecomline Excellent,boiler,206,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Ecomline Excellent,boiler,206,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Ecomline Excellent,boiler,206,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Ecomline Excellent,boiler,206,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp -Ecomline Excellent,boiler,206,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod -Ecomline Excellent,boiler,206,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp -Ecomline Excellent,boiler,206,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp -Ecomline Excellent,boiler,206,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp -Ecomline Excellent,boiler,206,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp -Ecomline Excellent,boiler,206,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress -Ecomline Excellent,boiler,206,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp -Ecomline Excellent,boiler,206,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp -Ecomline Excellent,boiler,206,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp +Ecomline Excellent,boiler,206,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Ecomline Excellent,boiler,206,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod +Ecomline Excellent,boiler,206,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp +Ecomline Excellent,boiler,206,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp +Ecomline Excellent,boiler,206,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp +Ecomline Excellent,boiler,206,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp +Ecomline Excellent,boiler,206,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress +Ecomline Excellent,boiler,206,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Ecomline Excellent,boiler,206,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp +Ecomline Excellent,boiler,206,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Ecomline Excellent,boiler,206,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Ecomline Excellent,boiler,206,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 -Ecomline Excellent,boiler,206,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr +Ecomline Excellent,boiler,206,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Ecomline Excellent,boiler,206,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Ecomline Excellent,boiler,206,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Ecomline Excellent,boiler,206,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat -Ecomline Excellent,boiler,206,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Ecomline Excellent,boiler,206,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Ecomline Excellent,boiler,206,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Ecomline Excellent,boiler,206,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow -Ecomline Excellent,boiler,206,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock -Ecomline Excellent,boiler,206,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Ecomline Excellent,boiler,206,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Ecomline Excellent,boiler,206,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Ecomline Excellent,boiler,206,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Ecomline Excellent,boiler,206,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Ecomline Excellent,boiler,206,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Ecomline Excellent,boiler,206,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Ecomline Excellent,boiler,206,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Ecomline Excellent,boiler,206,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Ecomline Excellent,boiler,206,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Ecomline Excellent,boiler,206,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff +Ecomline Excellent,boiler,206,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston +Ecomline Excellent,boiler,206,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Ecomline Excellent,boiler,206,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon -Ecomline Excellent,boiler,206,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase -Ecomline Excellent,boiler,206,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Ecomline Excellent,boiler,206,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Ecomline Excellent,boiler,206,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase +Ecomline Excellent,boiler,206,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend +Ecomline Excellent,boiler,206,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Ecomline Excellent,boiler,206,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode -Ecomline Excellent,boiler,206,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp +Ecomline Excellent,boiler,206,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Ecomline Excellent,boiler,206,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Ecomline Excellent,boiler,206,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Ecomline Excellent,boiler,206,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Ecomline Excellent,boiler,206,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump -Ecomline Excellent,boiler,206,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax -Ecomline Excellent,boiler,206,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin +Ecomline Excellent,boiler,206,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax +Ecomline Excellent,boiler,206,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Ecomline Excellent,boiler,206,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Ecomline Excellent,boiler,206,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Ecomline Excellent,boiler,206,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp -Ecomline Excellent,boiler,206,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Ecomline Excellent,boiler,206,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow -Ecomline Excellent,boiler,206,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Ecomline Excellent,boiler,206,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Ecomline Excellent,boiler,206,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay +Ecomline Excellent,boiler,206,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp +Ecomline Excellent,boiler,206,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow +Ecomline Excellent,boiler,206,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow +Ecomline Excellent,boiler,206,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow +Ecomline Excellent,boiler,206,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Ecomline Excellent,boiler,206,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Ecomline Excellent,boiler,206,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Ecomline Excellent,boiler,206,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Ecomline Excellent,boiler,206,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Ecomline Excellent,boiler,206,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Ecomline Excellent,boiler,206,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Ecomline Excellent,boiler,206,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Ecomline Excellent,boiler,206,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode -Ecomline Excellent,boiler,206,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber +Ecomline Excellent,boiler,206,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Ecomline Excellent,boiler,206,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Ecomline Excellent,boiler,206,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance -Ecomline Excellent,boiler,206,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime +Ecomline Excellent,boiler,206,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Ecomline Excellent,boiler,206,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Ecomline Excellent,boiler,206,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops -Ecomline Excellent,boiler,206,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp -Ecomline Excellent,boiler,206,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated -Ecomline Excellent,boiler,206,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp -Ecomline Excellent,boiler,206,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp -Ecomline Excellent,boiler,206,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow -Ecomline Excellent,boiler,206,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus -Ecomline Excellent,boiler,206,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff -Ecomline Excellent,boiler,206,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle -Ecomline Excellent,boiler,206,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp -Ecomline Excellent,boiler,206,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype -Ecomline Excellent,boiler,206,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort -Ecomline Excellent,boiler,206,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 -Ecomline Excellent,boiler,206,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset -Ecomline Excellent,boiler,206,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization -Ecomline Excellent,boiler,206,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Ecomline Excellent,boiler,206,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp -Ecomline Excellent,boiler,206,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump -Ecomline Excellent,boiler,206,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype -Ecomline Excellent,boiler,206,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston -Ecomline Excellent,boiler,206,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Ecomline Excellent,boiler,206,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp -Ecomline Excellent,boiler,206,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode -Ecomline Excellent,boiler,206,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc -Ecomline Excellent,boiler,206,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp -Ecomline Excellent,boiler,206,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 -Ecomline Excellent,boiler,206,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow -Ecomline Excellent,boiler,206,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 -Ecomline Excellent,boiler,206,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 -Ecomline Excellent,boiler,206,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated -Ecomline Excellent,boiler,206,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime -Ecomline Excellent,boiler,206,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting -Ecomline Excellent,boiler,206,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging -Ecomline Excellent,boiler,206,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging -Ecomline Excellent,boiler,206,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok -Ecomline Excellent,boiler,206,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive -Ecomline Excellent,boiler,206,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve -Ecomline Excellent,boiler,206,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower -Ecomline Excellent,boiler,206,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp -Ecomline Excellent,boiler,206,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Ecomline Excellent,boiler,206,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Ecomline Excellent,boiler,206,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Ecomline Excellent,boiler,206,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower -Ecomline Excellent,boiler,206,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal -Ecomline Excellent,boiler,206,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Ecomline Excellent,boiler,206,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Ecomline Excellent,boiler,206,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp +Ecomline Excellent,boiler,206,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat +Ecomline Excellent,boiler,206,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Ecomline Excellent,boiler,206,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat +Ecomline Excellent,boiler,206,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Ecomline Excellent,boiler,206,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 +Ecomline Excellent,boiler,206,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Ecomline Excellent,boiler,206,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated +Ecomline Excellent,boiler,206,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp +Ecomline Excellent,boiler,206,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp +Ecomline Excellent,boiler,206,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow +Ecomline Excellent,boiler,206,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus +Ecomline Excellent,boiler,206,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff +Ecomline Excellent,boiler,206,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle +Ecomline Excellent,boiler,206,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp +Ecomline Excellent,boiler,206,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type +Ecomline Excellent,boiler,206,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort +Ecomline Excellent,boiler,206,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1 +Ecomline Excellent,boiler,206,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset +Ecomline Excellent,boiler,206,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization +Ecomline Excellent,boiler,206,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower +Ecomline Excellent,boiler,206,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp +Ecomline Excellent,boiler,206,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump +Ecomline Excellent,boiler,206,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype +Ecomline Excellent,boiler,206,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston +Ecomline Excellent,boiler,206,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff +Ecomline Excellent,boiler,206,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp +Ecomline Excellent,boiler,206,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode +Ecomline Excellent,boiler,206,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ +Ecomline Excellent,boiler,206,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp +Ecomline Excellent,boiler,206,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2 +Ecomline Excellent,boiler,206,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow +Ecomline Excellent,boiler,206,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1 +Ecomline Excellent,boiler,206,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2 +Ecomline Excellent,boiler,206,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated +Ecomline Excellent,boiler,206,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime +Ecomline Excellent,boiler,206,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting +Ecomline Excellent,boiler,206,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging +Ecomline Excellent,boiler,206,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging +Ecomline Excellent,boiler,206,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok +Ecomline Excellent,boiler,206,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active +Ecomline Excellent,boiler,206,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve +Ecomline Excellent,boiler,206,setpumppower,set pump power,uint8 (>=0<=100),%,false,sensor.boiler_dhw_set_pump_power,sensor.boiler_dhw_setpumppower +Ecomline Excellent,boiler,206,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp +Ecomline Excellent,boiler,206,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp +Ecomline Excellent,boiler,206,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts +Ecomline Excellent,boiler,206,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm +Ecomline Excellent,boiler,206,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Ecomline Excellent,boiler,206,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Ecomline Excellent,boiler,206,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Ecomline Excellent,boiler,206,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww -Cascade MC400,boiler,210,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1 +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2 +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1 +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2 +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,setpumppower,set pump power,uint8 (>=0<=100),%,false,sensor.boiler_dhw_set_pump_power,sensor.boiler_dhw_setpumppower +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Cascade MC400,boiler,210,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Cascade MC400,boiler,210,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Cascade MC400,boiler,210,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Cascade MC400,boiler,210,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Cascade MC400,boiler,210,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp -Cascade MC400,boiler,210,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod -Cascade MC400,boiler,210,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp -Cascade MC400,boiler,210,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp -Cascade MC400,boiler,210,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp -Cascade MC400,boiler,210,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp -Cascade MC400,boiler,210,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress -Cascade MC400,boiler,210,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp -Cascade MC400,boiler,210,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp -Cascade MC400,boiler,210,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp +Cascade MC400,boiler,210,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Cascade MC400,boiler,210,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod +Cascade MC400,boiler,210,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp +Cascade MC400,boiler,210,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp +Cascade MC400,boiler,210,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp +Cascade MC400,boiler,210,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp +Cascade MC400,boiler,210,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress +Cascade MC400,boiler,210,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Cascade MC400,boiler,210,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp +Cascade MC400,boiler,210,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Cascade MC400,boiler,210,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Cascade MC400,boiler,210,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 -Cascade MC400,boiler,210,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr +Cascade MC400,boiler,210,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Cascade MC400,boiler,210,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Cascade MC400,boiler,210,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Cascade MC400,boiler,210,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat -Cascade MC400,boiler,210,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Cascade MC400,boiler,210,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Cascade MC400,boiler,210,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Cascade MC400,boiler,210,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow -Cascade MC400,boiler,210,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock -Cascade MC400,boiler,210,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Cascade MC400,boiler,210,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Cascade MC400,boiler,210,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Cascade MC400,boiler,210,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Cascade MC400,boiler,210,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Cascade MC400,boiler,210,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Cascade MC400,boiler,210,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Cascade MC400,boiler,210,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Cascade MC400,boiler,210,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Cascade MC400,boiler,210,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Cascade MC400,boiler,210,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff +Cascade MC400,boiler,210,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston +Cascade MC400,boiler,210,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Cascade MC400,boiler,210,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon -Cascade MC400,boiler,210,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase -Cascade MC400,boiler,210,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Cascade MC400,boiler,210,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Cascade MC400,boiler,210,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase +Cascade MC400,boiler,210,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend +Cascade MC400,boiler,210,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Cascade MC400,boiler,210,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode -Cascade MC400,boiler,210,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp +Cascade MC400,boiler,210,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Cascade MC400,boiler,210,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Cascade MC400,boiler,210,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Cascade MC400,boiler,210,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Cascade MC400,boiler,210,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump -Cascade MC400,boiler,210,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax -Cascade MC400,boiler,210,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin +Cascade MC400,boiler,210,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax +Cascade MC400,boiler,210,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Cascade MC400,boiler,210,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Cascade MC400,boiler,210,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Cascade MC400,boiler,210,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp -Cascade MC400,boiler,210,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Cascade MC400,boiler,210,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow -Cascade MC400,boiler,210,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Cascade MC400,boiler,210,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Cascade MC400,boiler,210,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay +Cascade MC400,boiler,210,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp +Cascade MC400,boiler,210,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow +Cascade MC400,boiler,210,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow +Cascade MC400,boiler,210,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow +Cascade MC400,boiler,210,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Cascade MC400,boiler,210,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Cascade MC400,boiler,210,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Cascade MC400,boiler,210,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Cascade MC400,boiler,210,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Cascade MC400,boiler,210,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Cascade MC400,boiler,210,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Cascade MC400,boiler,210,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Cascade MC400,boiler,210,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode -Cascade MC400,boiler,210,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber +Cascade MC400,boiler,210,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Cascade MC400,boiler,210,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Cascade MC400,boiler,210,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance -Cascade MC400,boiler,210,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime +Cascade MC400,boiler,210,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Cascade MC400,boiler,210,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Cascade MC400,boiler,210,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops -Cascade MC400,boiler,210,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp -Cascade MC400,boiler,210,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated -Cascade MC400,boiler,210,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp -Cascade MC400,boiler,210,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp -Cascade MC400,boiler,210,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow -Cascade MC400,boiler,210,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus -Cascade MC400,boiler,210,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff -Cascade MC400,boiler,210,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle -Cascade MC400,boiler,210,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp -Cascade MC400,boiler,210,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype -Cascade MC400,boiler,210,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort -Cascade MC400,boiler,210,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 -Cascade MC400,boiler,210,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset -Cascade MC400,boiler,210,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization -Cascade MC400,boiler,210,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Cascade MC400,boiler,210,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp -Cascade MC400,boiler,210,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump -Cascade MC400,boiler,210,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype -Cascade MC400,boiler,210,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston -Cascade MC400,boiler,210,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Cascade MC400,boiler,210,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp -Cascade MC400,boiler,210,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode -Cascade MC400,boiler,210,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc -Cascade MC400,boiler,210,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp -Cascade MC400,boiler,210,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 -Cascade MC400,boiler,210,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow -Cascade MC400,boiler,210,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 -Cascade MC400,boiler,210,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 -Cascade MC400,boiler,210,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated -Cascade MC400,boiler,210,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime -Cascade MC400,boiler,210,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting -Cascade MC400,boiler,210,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging -Cascade MC400,boiler,210,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging -Cascade MC400,boiler,210,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok -Cascade MC400,boiler,210,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive -Cascade MC400,boiler,210,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve -Cascade MC400,boiler,210,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower -Cascade MC400,boiler,210,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp -Cascade MC400,boiler,210,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Cascade MC400,boiler,210,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Cascade MC400,boiler,210,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Cascade MC400,boiler,210,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower -Cascade MC400,boiler,210,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal -Cascade MC400,boiler,210,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Cascade MC400,boiler,210,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww -EasyControl Adapter,boiler,211,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Cascade MC400,boiler,210,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp +Cascade MC400,boiler,210,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat +Cascade MC400,boiler,210,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Cascade MC400,boiler,210,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat +Cascade MC400,boiler,210,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Cascade MC400,boiler,210,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 +Cascade MC400,boiler,210,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Cascade MC400,boiler,210,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated +Cascade MC400,boiler,210,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp +Cascade MC400,boiler,210,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp +Cascade MC400,boiler,210,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow +Cascade MC400,boiler,210,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus +Cascade MC400,boiler,210,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff +Cascade MC400,boiler,210,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle +Cascade MC400,boiler,210,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp +Cascade MC400,boiler,210,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type +Cascade MC400,boiler,210,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort +Cascade MC400,boiler,210,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1 +Cascade MC400,boiler,210,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset +Cascade MC400,boiler,210,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization +Cascade MC400,boiler,210,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower +Cascade MC400,boiler,210,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp +Cascade MC400,boiler,210,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump +Cascade MC400,boiler,210,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype +Cascade MC400,boiler,210,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston +Cascade MC400,boiler,210,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff +Cascade MC400,boiler,210,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp +Cascade MC400,boiler,210,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode +Cascade MC400,boiler,210,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ +Cascade MC400,boiler,210,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp +Cascade MC400,boiler,210,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2 +Cascade MC400,boiler,210,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow +Cascade MC400,boiler,210,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1 +Cascade MC400,boiler,210,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2 +Cascade MC400,boiler,210,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated +Cascade MC400,boiler,210,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime +Cascade MC400,boiler,210,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting +Cascade MC400,boiler,210,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging +Cascade MC400,boiler,210,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging +Cascade MC400,boiler,210,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok +Cascade MC400,boiler,210,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active +Cascade MC400,boiler,210,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve +Cascade MC400,boiler,210,setpumppower,set pump power,uint8 (>=0<=100),%,false,sensor.boiler_dhw_set_pump_power,sensor.boiler_dhw_setpumppower +Cascade MC400,boiler,210,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp +Cascade MC400,boiler,210,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp +Cascade MC400,boiler,210,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts +Cascade MC400,boiler,210,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm +Cascade MC400,boiler,210,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Cascade MC400,boiler,210,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Cascade MC400,boiler,210,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Cascade MC400,boiler,210,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +EasyControl Adapter,boiler,211,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset EasyControl Adapter,boiler,211,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff EasyControl Adapter,boiler,211,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive EasyControl Adapter,boiler,211,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -EasyControl Adapter,boiler,211,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp -EasyControl Adapter,boiler,211,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod -EasyControl Adapter,boiler,211,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp -EasyControl Adapter,boiler,211,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp -EasyControl Adapter,boiler,211,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp -EasyControl Adapter,boiler,211,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp -EasyControl Adapter,boiler,211,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress -EasyControl Adapter,boiler,211,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp -EasyControl Adapter,boiler,211,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp -EasyControl Adapter,boiler,211,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp +EasyControl Adapter,boiler,211,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +EasyControl Adapter,boiler,211,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod +EasyControl Adapter,boiler,211,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp +EasyControl Adapter,boiler,211,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp +EasyControl Adapter,boiler,211,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp +EasyControl Adapter,boiler,211,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp +EasyControl Adapter,boiler,211,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress +EasyControl Adapter,boiler,211,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +EasyControl Adapter,boiler,211,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp +EasyControl Adapter,boiler,211,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp EasyControl Adapter,boiler,211,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas EasyControl Adapter,boiler,211,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 -EasyControl Adapter,boiler,211,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr +EasyControl Adapter,boiler,211,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr EasyControl Adapter,boiler,211,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork EasyControl Adapter,boiler,211,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork EasyControl Adapter,boiler,211,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat -EasyControl Adapter,boiler,211,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -EasyControl Adapter,boiler,211,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -EasyControl Adapter,boiler,211,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -EasyControl Adapter,boiler,211,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow -EasyControl Adapter,boiler,211,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock -EasyControl Adapter,boiler,211,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -EasyControl Adapter,boiler,211,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -EasyControl Adapter,boiler,211,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -EasyControl Adapter,boiler,211,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +EasyControl Adapter,boiler,211,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +EasyControl Adapter,boiler,211,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +EasyControl Adapter,boiler,211,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +EasyControl Adapter,boiler,211,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +EasyControl Adapter,boiler,211,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +EasyControl Adapter,boiler,211,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +EasyControl Adapter,boiler,211,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff +EasyControl Adapter,boiler,211,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston +EasyControl Adapter,boiler,211,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff EasyControl Adapter,boiler,211,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon -EasyControl Adapter,boiler,211,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase -EasyControl Adapter,boiler,211,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -EasyControl Adapter,boiler,211,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +EasyControl Adapter,boiler,211,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase +EasyControl Adapter,boiler,211,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend +EasyControl Adapter,boiler,211,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp EasyControl Adapter,boiler,211,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode -EasyControl Adapter,boiler,211,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp +EasyControl Adapter,boiler,211,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp EasyControl Adapter,boiler,211,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -EasyControl Adapter,boiler,211,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +EasyControl Adapter,boiler,211,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp EasyControl Adapter,boiler,211,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump -EasyControl Adapter,boiler,211,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax -EasyControl Adapter,boiler,211,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin +EasyControl Adapter,boiler,211,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax +EasyControl Adapter,boiler,211,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin EasyControl Adapter,boiler,211,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -EasyControl Adapter,boiler,211,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -EasyControl Adapter,boiler,211,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp -EasyControl Adapter,boiler,211,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -EasyControl Adapter,boiler,211,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow -EasyControl Adapter,boiler,211,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -EasyControl Adapter,boiler,211,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +EasyControl Adapter,boiler,211,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay +EasyControl Adapter,boiler,211,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp +EasyControl Adapter,boiler,211,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow +EasyControl Adapter,boiler,211,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow +EasyControl Adapter,boiler,211,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow +EasyControl Adapter,boiler,211,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts EasyControl Adapter,boiler,211,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin EasyControl Adapter,boiler,211,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin EasyControl Adapter,boiler,211,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -EasyControl Adapter,boiler,211,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +EasyControl Adapter,boiler,211,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts EasyControl Adapter,boiler,211,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime EasyControl Adapter,boiler,211,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode EasyControl Adapter,boiler,211,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode -EasyControl Adapter,boiler,211,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber +EasyControl Adapter,boiler,211,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber EasyControl Adapter,boiler,211,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage EasyControl Adapter,boiler,211,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance -EasyControl Adapter,boiler,211,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime +EasyControl Adapter,boiler,211,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime EasyControl Adapter,boiler,211,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate EasyControl Adapter,boiler,211,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops -EasyControl Adapter,boiler,211,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp -EasyControl Adapter,boiler,211,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated -EasyControl Adapter,boiler,211,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp -EasyControl Adapter,boiler,211,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp -EasyControl Adapter,boiler,211,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow -EasyControl Adapter,boiler,211,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus -EasyControl Adapter,boiler,211,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff -EasyControl Adapter,boiler,211,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle -EasyControl Adapter,boiler,211,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp -EasyControl Adapter,boiler,211,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype -EasyControl Adapter,boiler,211,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort -EasyControl Adapter,boiler,211,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 -EasyControl Adapter,boiler,211,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset -EasyControl Adapter,boiler,211,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization -EasyControl Adapter,boiler,211,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -EasyControl Adapter,boiler,211,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp -EasyControl Adapter,boiler,211,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump -EasyControl Adapter,boiler,211,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype -EasyControl Adapter,boiler,211,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston -EasyControl Adapter,boiler,211,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -EasyControl Adapter,boiler,211,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp -EasyControl Adapter,boiler,211,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode -EasyControl Adapter,boiler,211,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc -EasyControl Adapter,boiler,211,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp -EasyControl Adapter,boiler,211,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 -EasyControl Adapter,boiler,211,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow -EasyControl Adapter,boiler,211,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 -EasyControl Adapter,boiler,211,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 -EasyControl Adapter,boiler,211,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated -EasyControl Adapter,boiler,211,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime -EasyControl Adapter,boiler,211,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting -EasyControl Adapter,boiler,211,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging -EasyControl Adapter,boiler,211,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging -EasyControl Adapter,boiler,211,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok -EasyControl Adapter,boiler,211,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive -EasyControl Adapter,boiler,211,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve -EasyControl Adapter,boiler,211,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower -EasyControl Adapter,boiler,211,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp -EasyControl Adapter,boiler,211,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -EasyControl Adapter,boiler,211,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -EasyControl Adapter,boiler,211,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -EasyControl Adapter,boiler,211,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower -EasyControl Adapter,boiler,211,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal -EasyControl Adapter,boiler,211,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -EasyControl Adapter,boiler,211,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww -Greenstar HIU/Logamax kompakt WS170,boiler,219,netflowtemp,heat network flow temp,ushort (>=0<=3199),C,false,sensor.boiler_heat_network_flow_temp,sensor.boiler_netflowtemp -Greenstar HIU/Logamax kompakt WS170,boiler,219,heatvalve,heating valve,uint (>=0<=100),%,false,sensor.boiler_heating_valve,sensor.boiler_heatvalve -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwvalve,valve,uint (>=0<=100),%,false,sensor.boiler_valve,sensor.boiler_wwvalve -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow -Greenstar HIU/Logamax kompakt WS170,boiler,219,keepwarmtemp,keep warm temperature,uint (>=0<=254),C,true,number.boiler_keep_warm_temperature,number.boiler_keepwarmtemp -Greenstar HIU/Logamax kompakt WS170,boiler,219,setreturntemp,set temp return,uint (>=0<=254),C,true,number.boiler_set_temp_return,number.boiler_setreturntemp +EasyControl Adapter,boiler,211,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp +EasyControl Adapter,boiler,211,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat +EasyControl Adapter,boiler,211,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +EasyControl Adapter,boiler,211,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat +EasyControl Adapter,boiler,211,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +EasyControl Adapter,boiler,211,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 +EasyControl Adapter,boiler,211,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +EasyControl Adapter,boiler,211,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated +EasyControl Adapter,boiler,211,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp +EasyControl Adapter,boiler,211,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp +EasyControl Adapter,boiler,211,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow +EasyControl Adapter,boiler,211,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus +EasyControl Adapter,boiler,211,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff +EasyControl Adapter,boiler,211,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle +EasyControl Adapter,boiler,211,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp +EasyControl Adapter,boiler,211,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type +EasyControl Adapter,boiler,211,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort +EasyControl Adapter,boiler,211,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1 +EasyControl Adapter,boiler,211,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset +EasyControl Adapter,boiler,211,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization +EasyControl Adapter,boiler,211,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower +EasyControl Adapter,boiler,211,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp +EasyControl Adapter,boiler,211,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump +EasyControl Adapter,boiler,211,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype +EasyControl Adapter,boiler,211,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston +EasyControl Adapter,boiler,211,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff +EasyControl Adapter,boiler,211,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp +EasyControl Adapter,boiler,211,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode +EasyControl Adapter,boiler,211,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ +EasyControl Adapter,boiler,211,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp +EasyControl Adapter,boiler,211,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2 +EasyControl Adapter,boiler,211,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow +EasyControl Adapter,boiler,211,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1 +EasyControl Adapter,boiler,211,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2 +EasyControl Adapter,boiler,211,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated +EasyControl Adapter,boiler,211,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime +EasyControl Adapter,boiler,211,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting +EasyControl Adapter,boiler,211,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging +EasyControl Adapter,boiler,211,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging +EasyControl Adapter,boiler,211,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok +EasyControl Adapter,boiler,211,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active +EasyControl Adapter,boiler,211,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve +EasyControl Adapter,boiler,211,setpumppower,set pump power,uint8 (>=0<=100),%,false,sensor.boiler_dhw_set_pump_power,sensor.boiler_dhw_setpumppower +EasyControl Adapter,boiler,211,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp +EasyControl Adapter,boiler,211,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp +EasyControl Adapter,boiler,211,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts +EasyControl Adapter,boiler,211,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm +EasyControl Adapter,boiler,211,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +EasyControl Adapter,boiler,211,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +EasyControl Adapter,boiler,211,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +EasyControl Adapter,boiler,211,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Greenstar HIU/Logamax kompakt WS170,boiler,219,netflowtemp,heat network flow temp,uint16 (>=0<=3199),C,false,sensor.boiler_heat_network_flow_temp,sensor.boiler_netflowtemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,heatvalve,heating valve,uint8 (>=0<=100),%,false,sensor.boiler_heating_valve,sensor.boiler_heatvalve +Greenstar HIU/Logamax kompakt WS170,boiler,219,dhwvalve,valve,uint8 (>=0<=100),%,false,sensor.boiler_dhw_valve,sensor.boiler_dhw_dhwvalve +Greenstar HIU/Logamax kompakt WS170,boiler,219,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow +Greenstar HIU/Logamax kompakt WS170,boiler,219,keepwarmtemp,keep warm temperature,uint8 (>=0<=254),C,true,number.boiler_keep_warm_temperature,number.boiler_keepwarmtemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,setreturntemp,set temp return,uint8 (>=0<=254),C,true,number.boiler_set_temp_return,number.boiler_setreturntemp Greenstar HIU/Logamax kompakt WS170,boiler,219,heating,heating,boolean, ,false,binary_sensor.boiler_heating,binary_sensor.boiler_heating -Greenstar HIU/Logamax kompakt WS170,boiler,219,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Greenstar HIU/Logamax kompakt WS170,boiler,219,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Greenstar HIU/Logamax kompakt WS170,boiler,219,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Greenstar HIU/Logamax kompakt WS170,boiler,219,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Greenstar HIU/Logamax kompakt WS170,boiler,219,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Greenstar HIU/Logamax kompakt WS170,boiler,219,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp -Greenstar HIU/Logamax kompakt WS170,boiler,219,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod -Greenstar HIU/Logamax kompakt WS170,boiler,219,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp -Greenstar HIU/Logamax kompakt WS170,boiler,219,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp -Greenstar HIU/Logamax kompakt WS170,boiler,219,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp -Greenstar HIU/Logamax kompakt WS170,boiler,219,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp -Greenstar HIU/Logamax kompakt WS170,boiler,219,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress -Greenstar HIU/Logamax kompakt WS170,boiler,219,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp -Greenstar HIU/Logamax kompakt WS170,boiler,219,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod +Greenstar HIU/Logamax kompakt WS170,boiler,219,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress +Greenstar HIU/Logamax kompakt WS170,boiler,219,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Greenstar HIU/Logamax kompakt WS170,boiler,219,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Greenstar HIU/Logamax kompakt WS170,boiler,219,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Greenstar HIU/Logamax kompakt WS170,boiler,219,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump -Greenstar HIU/Logamax kompakt WS170,boiler,219,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax -Greenstar HIU/Logamax kompakt WS170,boiler,219,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin +Greenstar HIU/Logamax kompakt WS170,boiler,219,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax +Greenstar HIU/Logamax kompakt WS170,boiler,219,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Greenstar HIU/Logamax kompakt WS170,boiler,219,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Greenstar HIU/Logamax kompakt WS170,boiler,219,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Greenstar HIU/Logamax kompakt WS170,boiler,219,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp -Greenstar HIU/Logamax kompakt WS170,boiler,219,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Greenstar HIU/Logamax kompakt WS170,boiler,219,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow -Greenstar HIU/Logamax kompakt WS170,boiler,219,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Greenstar HIU/Logamax kompakt WS170,boiler,219,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Greenstar HIU/Logamax kompakt WS170,boiler,219,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay +Greenstar HIU/Logamax kompakt WS170,boiler,219,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow +Greenstar HIU/Logamax kompakt WS170,boiler,219,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow +Greenstar HIU/Logamax kompakt WS170,boiler,219,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow +Greenstar HIU/Logamax kompakt WS170,boiler,219,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Greenstar HIU/Logamax kompakt WS170,boiler,219,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Greenstar HIU/Logamax kompakt WS170,boiler,219,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Greenstar HIU/Logamax kompakt WS170,boiler,219,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Greenstar HIU/Logamax kompakt WS170,boiler,219,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Greenstar HIU/Logamax kompakt WS170,boiler,219,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Greenstar HIU/Logamax kompakt WS170,boiler,219,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Greenstar HIU/Logamax kompakt WS170,boiler,219,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Greenstar HIU/Logamax kompakt WS170,boiler,219,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode -Greenstar HIU/Logamax kompakt WS170,boiler,219,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber +Greenstar HIU/Logamax kompakt WS170,boiler,219,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Greenstar HIU/Logamax kompakt WS170,boiler,219,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Greenstar HIU/Logamax kompakt WS170,boiler,219,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance -Greenstar HIU/Logamax kompakt WS170,boiler,219,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime +Greenstar HIU/Logamax kompakt WS170,boiler,219,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Greenstar HIU/Logamax kompakt WS170,boiler,219,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Greenstar HIU/Logamax kompakt WS170,boiler,219,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops -Greenstar HIU/Logamax kompakt WS170,boiler,219,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive -Greenstar HIU/Logamax kompakt WS170,boiler,219,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Greenstar HIU/Logamax kompakt WS170,boiler,219,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Logamax Plus GB122/Condense 2300,boiler,234,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset +Greenstar HIU/Logamax kompakt WS170,boiler,219,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat +Greenstar HIU/Logamax kompakt WS170,boiler,219,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Greenstar HIU/Logamax kompakt WS170,boiler,219,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat +Greenstar HIU/Logamax kompakt WS170,boiler,219,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Greenstar HIU/Logamax kompakt WS170,boiler,219,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 +Greenstar HIU/Logamax kompakt WS170,boiler,219,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Greenstar HIU/Logamax kompakt WS170,boiler,219,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated +Greenstar HIU/Logamax kompakt WS170,boiler,219,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow +Greenstar HIU/Logamax kompakt WS170,boiler,219,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus +Greenstar HIU/Logamax kompakt WS170,boiler,219,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff +Greenstar HIU/Logamax kompakt WS170,boiler,219,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle +Greenstar HIU/Logamax kompakt WS170,boiler,219,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type +Greenstar HIU/Logamax kompakt WS170,boiler,219,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort +Greenstar HIU/Logamax kompakt WS170,boiler,219,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1 +Greenstar HIU/Logamax kompakt WS170,boiler,219,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset +Greenstar HIU/Logamax kompakt WS170,boiler,219,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization +Greenstar HIU/Logamax kompakt WS170,boiler,219,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower +Greenstar HIU/Logamax kompakt WS170,boiler,219,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump +Greenstar HIU/Logamax kompakt WS170,boiler,219,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype +Greenstar HIU/Logamax kompakt WS170,boiler,219,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston +Greenstar HIU/Logamax kompakt WS170,boiler,219,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff +Greenstar HIU/Logamax kompakt WS170,boiler,219,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode +Greenstar HIU/Logamax kompakt WS170,boiler,219,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ +Greenstar HIU/Logamax kompakt WS170,boiler,219,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2 +Greenstar HIU/Logamax kompakt WS170,boiler,219,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow +Greenstar HIU/Logamax kompakt WS170,boiler,219,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1 +Greenstar HIU/Logamax kompakt WS170,boiler,219,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2 +Greenstar HIU/Logamax kompakt WS170,boiler,219,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated +Greenstar HIU/Logamax kompakt WS170,boiler,219,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime +Greenstar HIU/Logamax kompakt WS170,boiler,219,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting +Greenstar HIU/Logamax kompakt WS170,boiler,219,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging +Greenstar HIU/Logamax kompakt WS170,boiler,219,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging +Greenstar HIU/Logamax kompakt WS170,boiler,219,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok +Greenstar HIU/Logamax kompakt WS170,boiler,219,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active +Greenstar HIU/Logamax kompakt WS170,boiler,219,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve +Greenstar HIU/Logamax kompakt WS170,boiler,219,setpumppower,set pump power,uint8 (>=0<=100),%,false,sensor.boiler_dhw_set_pump_power,sensor.boiler_dhw_setpumppower +Greenstar HIU/Logamax kompakt WS170,boiler,219,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp +Greenstar HIU/Logamax kompakt WS170,boiler,219,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts +Greenstar HIU/Logamax kompakt WS170,boiler,219,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm +Logamax Plus GB122/Condense 2300,boiler,234,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Logamax Plus GB122/Condense 2300,boiler,234,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Logamax Plus GB122/Condense 2300,boiler,234,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Logamax Plus GB122/Condense 2300,boiler,234,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive -Logamax Plus GB122/Condense 2300,boiler,234,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp -Logamax Plus GB122/Condense 2300,boiler,234,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod -Logamax Plus GB122/Condense 2300,boiler,234,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp -Logamax Plus GB122/Condense 2300,boiler,234,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp -Logamax Plus GB122/Condense 2300,boiler,234,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp -Logamax Plus GB122/Condense 2300,boiler,234,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp -Logamax Plus GB122/Condense 2300,boiler,234,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress -Logamax Plus GB122/Condense 2300,boiler,234,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp -Logamax Plus GB122/Condense 2300,boiler,234,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp -Logamax Plus GB122/Condense 2300,boiler,234,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp +Logamax Plus GB122/Condense 2300,boiler,234,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp +Logamax Plus GB122/Condense 2300,boiler,234,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod +Logamax Plus GB122/Condense 2300,boiler,234,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp +Logamax Plus GB122/Condense 2300,boiler,234,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp +Logamax Plus GB122/Condense 2300,boiler,234,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp +Logamax Plus GB122/Condense 2300,boiler,234,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp +Logamax Plus GB122/Condense 2300,boiler,234,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress +Logamax Plus GB122/Condense 2300,boiler,234,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp +Logamax Plus GB122/Condense 2300,boiler,234,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp +Logamax Plus GB122/Condense 2300,boiler,234,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Logamax Plus GB122/Condense 2300,boiler,234,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Logamax Plus GB122/Condense 2300,boiler,234,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 -Logamax Plus GB122/Condense 2300,boiler,234,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr +Logamax Plus GB122/Condense 2300,boiler,234,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Logamax Plus GB122/Condense 2300,boiler,234,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Logamax Plus GB122/Condense 2300,boiler,234,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Logamax Plus GB122/Condense 2300,boiler,234,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat -Logamax Plus GB122/Condense 2300,boiler,234,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower -Logamax Plus GB122/Condense 2300,boiler,234,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower -Logamax Plus GB122/Condense 2300,boiler,234,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod -Logamax Plus GB122/Condense 2300,boiler,234,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow -Logamax Plus GB122/Condense 2300,boiler,234,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock -Logamax Plus GB122/Condense 2300,boiler,234,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston -Logamax Plus GB122/Condense 2300,boiler,234,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff -Logamax Plus GB122/Condense 2300,boiler,234,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston -Logamax Plus GB122/Condense 2300,boiler,234,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff +Logamax Plus GB122/Condense 2300,boiler,234,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower +Logamax Plus GB122/Condense 2300,boiler,234,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower +Logamax Plus GB122/Condense 2300,boiler,234,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod +Logamax Plus GB122/Condense 2300,boiler,234,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow +Logamax Plus GB122/Condense 2300,boiler,234,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock +Logamax Plus GB122/Condense 2300,boiler,234,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston +Logamax Plus GB122/Condense 2300,boiler,234,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff +Logamax Plus GB122/Condense 2300,boiler,234,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston +Logamax Plus GB122/Condense 2300,boiler,234,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Logamax Plus GB122/Condense 2300,boiler,234,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon -Logamax Plus GB122/Condense 2300,boiler,234,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase -Logamax Plus GB122/Condense 2300,boiler,234,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Logamax Plus GB122/Condense 2300,boiler,234,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Logamax Plus GB122/Condense 2300,boiler,234,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase +Logamax Plus GB122/Condense 2300,boiler,234,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend +Logamax Plus GB122/Condense 2300,boiler,234,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Logamax Plus GB122/Condense 2300,boiler,234,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode -Logamax Plus GB122/Condense 2300,boiler,234,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp +Logamax Plus GB122/Condense 2300,boiler,234,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Logamax Plus GB122/Condense 2300,boiler,234,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated -Logamax Plus GB122/Condense 2300,boiler,234,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp +Logamax Plus GB122/Condense 2300,boiler,234,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Logamax Plus GB122/Condense 2300,boiler,234,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump -Logamax Plus GB122/Condense 2300,boiler,234,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax -Logamax Plus GB122/Condense 2300,boiler,234,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin +Logamax Plus GB122/Condense 2300,boiler,234,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax +Logamax Plus GB122/Condense 2300,boiler,234,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Logamax Plus GB122/Condense 2300,boiler,234,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode -Logamax Plus GB122/Condense 2300,boiler,234,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay -Logamax Plus GB122/Condense 2300,boiler,234,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp -Logamax Plus GB122/Condense 2300,boiler,234,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow -Logamax Plus GB122/Condense 2300,boiler,234,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow -Logamax Plus GB122/Condense 2300,boiler,234,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow -Logamax Plus GB122/Condense 2300,boiler,234,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts +Logamax Plus GB122/Condense 2300,boiler,234,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay +Logamax Plus GB122/Condense 2300,boiler,234,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp +Logamax Plus GB122/Condense 2300,boiler,234,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow +Logamax Plus GB122/Condense 2300,boiler,234,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow +Logamax Plus GB122/Condense 2300,boiler,234,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow +Logamax Plus GB122/Condense 2300,boiler,234,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Logamax Plus GB122/Condense 2300,boiler,234,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Logamax Plus GB122/Condense 2300,boiler,234,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Logamax Plus GB122/Condense 2300,boiler,234,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin -Logamax Plus GB122/Condense 2300,boiler,234,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts +Logamax Plus GB122/Condense 2300,boiler,234,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Logamax Plus GB122/Condense 2300,boiler,234,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Logamax Plus GB122/Condense 2300,boiler,234,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Logamax Plus GB122/Condense 2300,boiler,234,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode -Logamax Plus GB122/Condense 2300,boiler,234,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber +Logamax Plus GB122/Condense 2300,boiler,234,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Logamax Plus GB122/Condense 2300,boiler,234,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Logamax Plus GB122/Condense 2300,boiler,234,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance -Logamax Plus GB122/Condense 2300,boiler,234,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime +Logamax Plus GB122/Condense 2300,boiler,234,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Logamax Plus GB122/Condense 2300,boiler,234,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Logamax Plus GB122/Condense 2300,boiler,234,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops -Logamax Plus GB122/Condense 2300,boiler,234,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp -Logamax Plus GB122/Condense 2300,boiler,234,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated -Logamax Plus GB122/Condense 2300,boiler,234,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp -Logamax Plus GB122/Condense 2300,boiler,234,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp -Logamax Plus GB122/Condense 2300,boiler,234,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow -Logamax Plus GB122/Condense 2300,boiler,234,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus -Logamax Plus GB122/Condense 2300,boiler,234,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff -Logamax Plus GB122/Condense 2300,boiler,234,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle -Logamax Plus GB122/Condense 2300,boiler,234,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp -Logamax Plus GB122/Condense 2300,boiler,234,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype -Logamax Plus GB122/Condense 2300,boiler,234,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort -Logamax Plus GB122/Condense 2300,boiler,234,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 -Logamax Plus GB122/Condense 2300,boiler,234,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset -Logamax Plus GB122/Condense 2300,boiler,234,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization -Logamax Plus GB122/Condense 2300,boiler,234,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower -Logamax Plus GB122/Condense 2300,boiler,234,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp -Logamax Plus GB122/Condense 2300,boiler,234,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump -Logamax Plus GB122/Condense 2300,boiler,234,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype -Logamax Plus GB122/Condense 2300,boiler,234,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston -Logamax Plus GB122/Condense 2300,boiler,234,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff -Logamax Plus GB122/Condense 2300,boiler,234,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp -Logamax Plus GB122/Condense 2300,boiler,234,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode -Logamax Plus GB122/Condense 2300,boiler,234,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc -Logamax Plus GB122/Condense 2300,boiler,234,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp -Logamax Plus GB122/Condense 2300,boiler,234,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 -Logamax Plus GB122/Condense 2300,boiler,234,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow -Logamax Plus GB122/Condense 2300,boiler,234,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 -Logamax Plus GB122/Condense 2300,boiler,234,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 -Logamax Plus GB122/Condense 2300,boiler,234,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated -Logamax Plus GB122/Condense 2300,boiler,234,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime -Logamax Plus GB122/Condense 2300,boiler,234,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting -Logamax Plus GB122/Condense 2300,boiler,234,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging -Logamax Plus GB122/Condense 2300,boiler,234,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging -Logamax Plus GB122/Condense 2300,boiler,234,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok -Logamax Plus GB122/Condense 2300,boiler,234,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive -Logamax Plus GB122/Condense 2300,boiler,234,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve -Logamax Plus GB122/Condense 2300,boiler,234,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower -Logamax Plus GB122/Condense 2300,boiler,234,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp -Logamax Plus GB122/Condense 2300,boiler,234,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp -Logamax Plus GB122/Condense 2300,boiler,234,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts -Logamax Plus GB122/Condense 2300,boiler,234,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm -Logamax Plus GB122/Condense 2300,boiler,234,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower -Logamax Plus GB122/Condense 2300,boiler,234,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal -Logamax Plus GB122/Condense 2300,boiler,234,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Logamax Plus GB122/Condense 2300,boiler,234,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww +Logamax Plus GB122/Condense 2300,boiler,234,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp +Logamax Plus GB122/Condense 2300,boiler,234,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat +Logamax Plus GB122/Condense 2300,boiler,234,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Logamax Plus GB122/Condense 2300,boiler,234,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat +Logamax Plus GB122/Condense 2300,boiler,234,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Logamax Plus GB122/Condense 2300,boiler,234,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 +Logamax Plus GB122/Condense 2300,boiler,234,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Logamax Plus GB122/Condense 2300,boiler,234,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated +Logamax Plus GB122/Condense 2300,boiler,234,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp +Logamax Plus GB122/Condense 2300,boiler,234,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp +Logamax Plus GB122/Condense 2300,boiler,234,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow +Logamax Plus GB122/Condense 2300,boiler,234,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus +Logamax Plus GB122/Condense 2300,boiler,234,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff +Logamax Plus GB122/Condense 2300,boiler,234,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle +Logamax Plus GB122/Condense 2300,boiler,234,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp +Logamax Plus GB122/Condense 2300,boiler,234,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type +Logamax Plus GB122/Condense 2300,boiler,234,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort +Logamax Plus GB122/Condense 2300,boiler,234,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1 +Logamax Plus GB122/Condense 2300,boiler,234,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset +Logamax Plus GB122/Condense 2300,boiler,234,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization +Logamax Plus GB122/Condense 2300,boiler,234,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower +Logamax Plus GB122/Condense 2300,boiler,234,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp +Logamax Plus GB122/Condense 2300,boiler,234,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump +Logamax Plus GB122/Condense 2300,boiler,234,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype +Logamax Plus GB122/Condense 2300,boiler,234,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston +Logamax Plus GB122/Condense 2300,boiler,234,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff +Logamax Plus GB122/Condense 2300,boiler,234,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp +Logamax Plus GB122/Condense 2300,boiler,234,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode +Logamax Plus GB122/Condense 2300,boiler,234,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ +Logamax Plus GB122/Condense 2300,boiler,234,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp +Logamax Plus GB122/Condense 2300,boiler,234,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2 +Logamax Plus GB122/Condense 2300,boiler,234,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow +Logamax Plus GB122/Condense 2300,boiler,234,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1 +Logamax Plus GB122/Condense 2300,boiler,234,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2 +Logamax Plus GB122/Condense 2300,boiler,234,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated +Logamax Plus GB122/Condense 2300,boiler,234,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime +Logamax Plus GB122/Condense 2300,boiler,234,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting +Logamax Plus GB122/Condense 2300,boiler,234,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging +Logamax Plus GB122/Condense 2300,boiler,234,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging +Logamax Plus GB122/Condense 2300,boiler,234,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok +Logamax Plus GB122/Condense 2300,boiler,234,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active +Logamax Plus GB122/Condense 2300,boiler,234,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve +Logamax Plus GB122/Condense 2300,boiler,234,setpumppower,set pump power,uint8 (>=0<=100),%,false,sensor.boiler_dhw_set_pump_power,sensor.boiler_dhw_setpumppower +Logamax Plus GB122/Condense 2300,boiler,234,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp +Logamax Plus GB122/Condense 2300,boiler,234,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp +Logamax Plus GB122/Condense 2300,boiler,234,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts +Logamax Plus GB122/Condense 2300,boiler,234,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm +Logamax Plus GB122/Condense 2300,boiler,234,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower +Logamax Plus GB122/Condense 2300,boiler,234,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal +Logamax Plus GB122/Condense 2300,boiler,234,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat +Logamax Plus GB122/Condense 2300,boiler,234,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw Logamatic TC100/Moduline Easy,thermostat,202,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode Logamatic TC100/Moduline Easy,thermostat,202,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode Logamatic TC100/Moduline Easy,thermostat,202,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime -Logamatic TC100/Moduline Easy,thermostat,202,seltemp,selected room temperature,short (>=-319<=319),C,false,sensor.thermostat_hc1_selected_room_temperature,sensor.thermostat_hc1_seltemp -Logamatic TC100/Moduline Easy,thermostat,202,currtemp,current room temperature,short (>=-319<=319),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +Logamatic TC100/Moduline Easy,thermostat,202,seltemp,selected room temperature,int16 (>=-319<=319),C,false,sensor.thermostat_hc1_selected_room_temperature,sensor.thermostat_hc1_seltemp +Logamatic TC100/Moduline Easy,thermostat,202,currtemp,current room temperature,int16 (>=-319<=319),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp Logamatic TC100/Moduline Easy,thermostat,202,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate EasyControl/CT200,thermostat,203,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode EasyControl/CT200,thermostat,203,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode EasyControl/CT200,thermostat,203,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime -EasyControl/CT200,thermostat,203,seltemp,selected room temperature,short (>=-319<=319),C,false,sensor.thermostat_hc1_selected_room_temperature,sensor.thermostat_hc1_seltemp -EasyControl/CT200,thermostat,203,currtemp,current room temperature,short (>=-319<=319),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +EasyControl/CT200,thermostat,203,seltemp,selected room temperature,int16 (>=-319<=319),C,false,sensor.thermostat_hc1_selected_room_temperature,sensor.thermostat_hc1_seltemp +EasyControl/CT200,thermostat,203,currtemp,current room temperature,int16 (>=-319<=319),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp EasyControl/CT200,thermostat,203,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate UI800/BC400,thermostat,4,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode UI800/BC400,thermostat,4,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode UI800/BC400,thermostat,4,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime -UI800/BC400,thermostat,4,intoffset,internal temperature offset,int (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset +UI800/BC400,thermostat,4,intoffset,internal temperature offset,int8 (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset UI800/BC400,thermostat,4,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry -UI800/BC400,thermostat,4,dampedoutdoortemp,damped outdoor temperature,short (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp -UI800/BC400,thermostat,4,floordrytemp,floor drying temperature,uint (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp +UI800/BC400,thermostat,4,dampedoutdoortemp,damped outdoor temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp +UI800/BC400,thermostat,4,floordrytemp,floor drying temperature,uint8 (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp UI800/BC400,thermostat,4,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building -UI800/BC400,thermostat,4,minexttemp,minimal external temperature,int (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp +UI800/BC400,thermostat,4,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp UI800/BC400,thermostat,4,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping -UI800/BC400,thermostat,4,wwsettemp,set temperature,uint (>=0<=254),C,true,number.thermostat_set_temperature,number.thermostat_wwsettemp -UI800/BC400,thermostat,4,wwmode,mode,enum [off\|eco+\|eco\|comfort\|auto], ,true,select.thermostat_mode,select.thermostat_wwmode -UI800/BC400,thermostat,4,wwmode,mode,enum [off\|eco+\|eco\|comfort\|auto], ,true,select.thermostat_wwc2_mode,select.thermostat_wwc2_wwmode -UI800/BC400,thermostat,4,wwsettemplow,set low temperature,uint (>=0<=254),C,true,number.thermostat_set_low_temperature,number.thermostat_wwsettemplow -UI800/BC400,thermostat,4,wwcircmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_circulation_pump_mode,select.thermostat_wwcircmode -UI800/BC400,thermostat,4,wwchargeduration,charge duration,uint (>=0<=3810),minutes,true,number.thermostat_charge_duration,number.thermostat_wwchargeduration -UI800/BC400,thermostat,4,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge -UI800/BC400,thermostat,4,wwextra1,circuit 1 extra,uint (>=0<=254),C,false,sensor.thermostat_circuit_1_extra,sensor.thermostat_wwextra1 -UI800/BC400,thermostat,4,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_disinfecting,switch.thermostat_wwdisinfecting -UI800/BC400,thermostat,4,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_disinfection_day,select.thermostat_wwdisinfectday -UI800/BC400,thermostat,4,wwdisinfecttime,disinfection time,uint (>=0<=1431),minutes,true,number.thermostat_disinfection_time,number.thermostat_wwdisinfecttime -UI800/BC400,thermostat,4,wwdailyheating,daily heating,boolean, ,true,switch.thermostat_daily_heating,switch.thermostat_wwdailyheating -UI800/BC400,thermostat,4,wwdailyheattime,daily heating time,uint (>=0<=1431),minutes,true,number.thermostat_daily_heating_time,number.thermostat_wwdailyheattime -UI800/BC400,thermostat,4,wwcircmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_wwc2_circulation_pump_mode,select.thermostat_wwc2_wwcircmode -UI800/BC400,thermostat,4,wwchargeduration,charge duration,uint (>=0<=3810),minutes,true,number.thermostat_wwc2_charge_duration,number.thermostat_wwc2_wwchargeduration -UI800/BC400,thermostat,4,wwcharge,charge,boolean, ,true,switch.thermostat_wwc2_charge,switch.thermostat_wwc2_wwcharge -UI800/BC400,thermostat,4,wwextra2,circuit 2 extra,uint (>=0<=254),C,false,sensor.thermostat_wwc2_circuit_2_extra,sensor.thermostat_wwc2_wwextra2 -UI800/BC400,thermostat,4,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_wwc2_disinfecting,switch.thermostat_wwc2_wwdisinfecting -UI800/BC400,thermostat,4,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_wwc2_disinfection_day,select.thermostat_wwc2_wwdisinfectday -UI800/BC400,thermostat,4,wwdisinfecttime,disinfection time,uint (>=0<=1431),minutes,true,number.thermostat_wwc2_disinfection_time,number.thermostat_wwc2_wwdisinfecttime -UI800/BC400,thermostat,4,wwdailyheating,daily heating,boolean, ,true,switch.thermostat_wwc2_daily_heating,switch.thermostat_wwc2_wwdailyheating -UI800/BC400,thermostat,4,wwdailyheattime,daily heating time,uint (>=0<=1431),minutes,true,number.thermostat_wwc2_daily_heating_time,number.thermostat_wwc2_wwdailyheattime UI800/BC400,thermostat,4,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy -UI800/BC400,thermostat,4,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp -UI800/BC400,thermostat,4,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio -UI800/BC400,thermostat,4,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor -UI800/BC400,thermostat,4,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor -UI800/BC400,thermostat,4,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler -UI800/BC400,thermostat,4,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler -UI800/BC400,thermostat,4,pvenableww,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenableww -UI800/BC400,thermostat,4,pvraiseheat,raise heating with PV,int (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat -UI800/BC400,thermostat,4,pvlowercool,lower cooling with PV,int (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool -UI800/BC400,thermostat,4,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -UI800/BC400,thermostat,4,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +UI800/BC400,thermostat,4,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp +UI800/BC400,thermostat,4,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio +UI800/BC400,thermostat,4,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor +UI800/BC400,thermostat,4,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor +UI800/BC400,thermostat,4,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler +UI800/BC400,thermostat,4,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler +UI800/BC400,thermostat,4,pvenabledhw,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenabledhw +UI800/BC400,thermostat,4,pvraiseheat,raise heating with PV,int8 (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat +UI800/BC400,thermostat,4,pvlowercool,lower cooling with PV,int8 (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool +UI800/BC400,thermostat,4,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +UI800/BC400,thermostat,4,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp UI800/BC400,thermostat,4,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate UI800/BC400,thermostat,4,mode,mode,enum [off\|manual\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode UI800/BC400,thermostat,4,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype -UI800/BC400,thermostat,4,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp -UI800/BC400,thermostat,4,manualtemp,manual temperature,uint (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp -UI800/BC400,thermostat,4,comforttemp,comfort temperature,uint (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp -UI800/BC400,thermostat,4,summertemp,summer temperature,uint (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp -UI800/BC400,thermostat,4,designtemp,design temperature,uint (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp -UI800/BC400,thermostat,4,offsettemp,offset temperature,int (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp -UI800/BC400,thermostat,4,minflowtemp,min flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp -UI800/BC400,thermostat,4,maxflowtemp,max flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp -UI800/BC400,thermostat,4,roominfluence,room influence,uint (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence -UI800/BC400,thermostat,4,roominflfactor,room influence factor,uint (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor -UI800/BC400,thermostat,4,curroominfl,current room influence,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl +UI800/BC400,thermostat,4,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp +UI800/BC400,thermostat,4,manualtemp,manual temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp +UI800/BC400,thermostat,4,comforttemp,comfort temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp +UI800/BC400,thermostat,4,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp +UI800/BC400,thermostat,4,designtemp,design temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp +UI800/BC400,thermostat,4,offsettemp,offset temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp +UI800/BC400,thermostat,4,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp +UI800/BC400,thermostat,4,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp +UI800/BC400,thermostat,4,roominfluence,room influence,uint8 (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence +UI800/BC400,thermostat,4,roominflfactor,room influence factor,uint8 (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor +UI800/BC400,thermostat,4,curroominfl,current room influence,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl UI800/BC400,thermostat,4,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode -UI800/BC400,thermostat,4,nofrosttemp,nofrost temperature,int (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp -UI800/BC400,thermostat,4,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp +UI800/BC400,thermostat,4,nofrosttemp,nofrost temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp +UI800/BC400,thermostat,4,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp UI800/BC400,thermostat,4,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype UI800/BC400,thermostat,4,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode UI800/BC400,thermostat,4,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode @@ -3258,93 +3392,92 @@ UI800/BC400,thermostat,4,summermode,summer mode,enum [winter\|summer], ,false,se UI800/BC400,thermostat,4,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate UI800/BC400,thermostat,4,controlmode,control mode,enum [weather compensated\|outside basepoint\|n/a\|room\|power\|constant], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode UI800/BC400,thermostat,4,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program -UI800/BC400,thermostat,4,tempautotemp,temporary set temperature automode,int (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp -UI800/BC400,thermostat,4,remoteseltemp,temporary set temperature from remote,int (>=-63<=63),C,false,sensor.thermostat_hc1_temporary_set_temperature_from_remote,sensor.thermostat_hc1_remoteseltemp -UI800/BC400,thermostat,4,fastheatup,fast heatup,uint (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup +UI800/BC400,thermostat,4,tempautotemp,temporary set temperature automode,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp +UI800/BC400,thermostat,4,remoteseltemp,temporary set temperature from remote,int8 (>=-63<=63),C,false,sensor.thermostat_hc1_temporary_set_temperature_from_remote,sensor.thermostat_hc1_remoteseltemp +UI800/BC400,thermostat,4,fastheatup,fast heatup,uint8 (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup UI800/BC400,thermostat,4,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization UI800/BC400,thermostat,4,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode -UI800/BC400,thermostat,4,noreducetemp,no reduce below temperature,int (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp -UI800/BC400,thermostat,4,reducetemp,off/reduce switch temperature,int (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp -UI800/BC400,thermostat,4,wwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_wwprio +UI800/BC400,thermostat,4,noreducetemp,no reduce below temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp +UI800/BC400,thermostat,4,reducetemp,off/reduce switch temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp +UI800/BC400,thermostat,4,dhwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_dhwprio UI800/BC400,thermostat,4,cooling,cooling,boolean, ,true,switch.thermostat_hc1_cooling,switch.thermostat_hc1_cooling UI800/BC400,thermostat,4,coolingon,cooling,boolean, ,false,binary_sensor.thermostat_hc1_cooling,binary_sensor.thermostat_hc1_coolingon UI800/BC400,thermostat,4,hpmode,HP Mode,enum [heating\|cooling\|heating&cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode -UI800/BC400,thermostat,4,dewoffset,dew point offset,uint (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset -UI800/BC400,thermostat,4,roomtempdiff,room temp difference,uint (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff -UI800/BC400,thermostat,4,hpminflowtemp,HP min. flow temp.,uint (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp +UI800/BC400,thermostat,4,dewoffset,dew point offset,uint8 (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset +UI800/BC400,thermostat,4,roomtempdiff,room temp difference,uint8 (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff +UI800/BC400,thermostat,4,hpminflowtemp,HP min. flow temp.,uint8 (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp UI800/BC400,thermostat,4,control,control device,enum [RC310\|RC200\|RC100\|RC100H\|TC100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control -UI800/BC400,thermostat,4,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp -UI800/BC400,thermostat,4,remotehum,room humidity from remote,uint (>=-1<=101),%,true,number.thermostat_hc1_room_humidity_from_remote,number.thermostat_hc1_remotehum -UI800/BC400,thermostat,4,heatondelay,heat-on delay,uint (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay -UI800/BC400,thermostat,4,heatoffdelay,heat-off delay,uint (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay -UI800/BC400,thermostat,4,instantstart,instant start,uint (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart +UI800/BC400,thermostat,4,remotetemp,room temperature from remote,int16 (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp +UI800/BC400,thermostat,4,remotehum,room humidity from remote,uint8 (>=-1<=101),%,true,number.thermostat_hc1_room_humidity_from_remote,number.thermostat_hc1_remotehum +UI800/BC400,thermostat,4,heatondelay,heat-on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay +UI800/BC400,thermostat,4,heatoffdelay,heat-off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay +UI800/BC400,thermostat,4,instantstart,instant start,uint8 (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart UI800/BC400,thermostat,4,boost,boost mode,boolean, ,true,switch.thermostat_hc1_boost_mode,switch.thermostat_hc1_boost -UI800/BC400,thermostat,4,boosttime,boost time,uint (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime +UI800/BC400,thermostat,4,boosttime,boost time,uint8 (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime +UI800/BC400,thermostat,4,mode,mode,enum [off\|eco+\|eco\|comfort\|auto], ,true,select.thermostat_dhw_mode,select.thermostat_dhw_mode +UI800/BC400,thermostat,4,settemp,set temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_temperature,number.thermostat_dhw_settemp +UI800/BC400,thermostat,4,settemplow,set low temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_low_temperature,number.thermostat_dhw_settemplow +UI800/BC400,thermostat,4,circmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_dhw_circulation_pump_mode,select.thermostat_dhw_circmode +UI800/BC400,thermostat,4,chargeduration,charge duration,uint8 (>=0<=3810),minutes,true,number.thermostat_dhw_charge_duration,number.thermostat_dhw_chargeduration +UI800/BC400,thermostat,4,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge +UI800/BC400,thermostat,4,extra,extra,uint8 (>=0<=254),C,false,sensor.thermostat_dhw_extra,sensor.thermostat_dhw_extra +UI800/BC400,thermostat,4,disinfecting,disinfecting,boolean, ,true,switch.thermostat_dhw_disinfecting,switch.thermostat_dhw_disinfecting +UI800/BC400,thermostat,4,disinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_dhw_disinfection_day,select.thermostat_dhw_disinfectday +UI800/BC400,thermostat,4,disinfecttime,disinfection time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_disinfection_time,number.thermostat_dhw_disinfecttime +UI800/BC400,thermostat,4,dailyheating,daily heating,boolean, ,true,switch.thermostat_dhw_daily_heating,switch.thermostat_dhw_dailyheating +UI800/BC400,thermostat,4,dailyheattime,daily heating time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_daily_heating_time,number.thermostat_dhw_dailyheattime RC10,thermostat,65,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode RC10,thermostat,65,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode RC10,thermostat,65,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime -RC10,thermostat,65,minexttemp,minimal external temperature,int (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp -RC10,thermostat,65,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -RC10,thermostat,65,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +RC10,thermostat,65,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp +RC10,thermostat,65,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +RC10,thermostat,65,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp RC10,thermostat,65,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate RC10,thermostat,65,mode,mode,enum [night\|day\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode RC10,thermostat,65,modetype,mode type,enum [night\|day], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype -RC10,thermostat,65,daytemp,day temperature,uint (>=0<=127),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp -RC10,thermostat,65,nighttemp,night temperature,uint (>=0<=127),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp +RC10,thermostat,65,daytemp,day temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp +RC10,thermostat,65,nighttemp,night temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp RC10,thermostat,65,program,program,enum [family\|morning\|evening\|am\|pm\|midday\|singles\|seniors], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program -RC10,thermostat,65,minflowtemp,min flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp -RC10,thermostat,65,maxflowtemp,max flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp -RC10,thermostat,65,tempautotemp,temporary set temperature automode,uint (>=0<=127),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp +RC10,thermostat,65,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp +RC10,thermostat,65,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp +RC10,thermostat,65,tempautotemp,temporary set temperature automode,uint8 (>=0<=127),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp RC10,thermostat,65,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype -RC10,thermostat,65,summertemp,summer temperature,uint (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp +RC10,thermostat,65,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp RC10,thermostat,65,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode -RC10,thermostat,65,remotetemp,room temperature from remote,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp +RC10,thermostat,65,remotetemp,room temperature from remote,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp RC30,thermostat,67,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode RC30,thermostat,67,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode RC30,thermostat,67,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime -RC30,thermostat,67,display,display,enum [internal temperature\|internal setpoint\|external temperature\|burner temperature\|ww temperature\|functioning mode\|time\|date\|smoke temperature], ,true,select.thermostat_display,select.thermostat_display +RC30,thermostat,67,display,display,enum [internal temperature\|internal setpoint\|external temperature\|burner temperature\|dhw temperature\|functioning mode\|time\|date\|smoke temperature], ,true,select.thermostat_display,select.thermostat_display RC30,thermostat,67,language,language,enum [german\|dutch\|french\|italian], ,false,sensor.thermostat_language,sensor.thermostat_language -RC30,thermostat,67,clockoffset,clock offset,int (>=-126<=126),seconds,true,number.thermostat_clock_offset,number.thermostat_clockoffset -RC30,thermostat,67,intoffset,internal temperature offset,int (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset -RC30,thermostat,67,minexttemp,minimal external temperature,int (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp -RC30,thermostat,67,inttemp1,temperature sensor 1,short (>=-3199<=3199),C,false,sensor.thermostat_temperature_sensor_1,sensor.thermostat_inttemp1 -RC30,thermostat,67,inttemp2,temperature sensor 2,short (>=-3199<=3199),C,false,sensor.thermostat_temperature_sensor_2,sensor.thermostat_inttemp2 +RC30,thermostat,67,clockoffset,clock offset,int8 (>=-126<=126),seconds,true,number.thermostat_clock_offset,number.thermostat_clockoffset +RC30,thermostat,67,intoffset,internal temperature offset,int8 (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset +RC30,thermostat,67,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp +RC30,thermostat,67,inttemp1,temperature sensor 1,int16 (>=-3199<=3199),C,false,sensor.thermostat_temperature_sensor_1,sensor.thermostat_inttemp1 +RC30,thermostat,67,inttemp2,temperature sensor 2,int16 (>=-3199<=3199),C,false,sensor.thermostat_temperature_sensor_2,sensor.thermostat_inttemp2 RC30,thermostat,67,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping -RC30,thermostat,67,dampedoutdoortemp,damped outdoor temperature,int (>=-126<=126),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp +RC30,thermostat,67,dampedoutdoortemp,damped outdoor temperature,int8 (>=-126<=126),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp RC30,thermostat,67,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building -RC30,thermostat,67,wwmode,mode,enum [off\|on\|auto], ,true,select.thermostat_mode,select.thermostat_wwmode -RC30,thermostat,67,wwcircmode,circulation pump mode,enum [off\|on\|auto], ,true,select.thermostat_circulation_pump_mode,select.thermostat_wwcircmode -RC30,thermostat,67,wwprogmode,program,enum [std prog\|own prog], ,true,select.thermostat_program,select.thermostat_wwprogmode -RC30,thermostat,67,wwcircprog,circulation program,enum [std prog\|own prog], ,true,select.thermostat_circulation_program,select.thermostat_wwcircprog -RC30,thermostat,67,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_disinfecting,switch.thermostat_wwdisinfecting -RC30,thermostat,67,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_disinfection_day,select.thermostat_wwdisinfectday -RC30,thermostat,67,wwdisinfecthour,disinfection hour,uint (>=0<=23), ,true,number.thermostat_disinfection_hour,number.thermostat_wwdisinfecthour -RC30,thermostat,67,wwmaxtemp,maximum temperature,uint (>=0<=254),C,true,number.thermostat_maximum_temperature,number.thermostat_wwmaxtemp -RC30,thermostat,67,wwonetimekey,one time key function,boolean, ,true,switch.thermostat_one_time_key_function,switch.thermostat_wwonetimekey -RC30,thermostat,67,wwswitchtime,program switchtime,string, ,true,sensor.thermostat_program_switchtime,sensor.thermostat_wwswitchtime -RC30,thermostat,67,wwcircswitchtime,circulation program switchtime,string, ,true,sensor.thermostat_circulation_program_switchtime,sensor.thermostat_wwcircswitchtime -RC30,thermostat,67,wwholidays,holiday dates,string, ,true,sensor.thermostat_holiday_dates,sensor.thermostat_wwholidays -RC30,thermostat,67,wwvacations,vacation dates,string, ,true,sensor.thermostat_vacation_dates,sensor.thermostat_wwvacations -RC30,thermostat,67,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -RC30,thermostat,67,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +RC30,thermostat,67,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +RC30,thermostat,67,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp RC30,thermostat,67,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate RC30,thermostat,67,mode,mode,enum [night\|day\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode RC30,thermostat,67,modetype,mode type,enum [night\|day], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype -RC30,thermostat,67,daytemp,day temperature,uint (>=10<=30),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp -RC30,thermostat,67,nighttemp,night temperature,uint (>=10<=30),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp -RC30,thermostat,67,designtemp,design temperature,uint (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp -RC30,thermostat,67,offsettemp,offset temperature,int (>=-5<=5),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp -RC30,thermostat,67,holidaytemp,holiday temperature,uint (>=5<=30),C,true,number.thermostat_hc1_holiday_temperature,number.thermostat_hc1_holidaytemp -RC30,thermostat,67,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp -RC30,thermostat,67,summertemp,summer temperature,uint (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp +RC30,thermostat,67,daytemp,day temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp +RC30,thermostat,67,nighttemp,night temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp +RC30,thermostat,67,designtemp,design temperature,uint8 (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp +RC30,thermostat,67,offsettemp,offset temperature,int8 (>=-5<=5),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp +RC30,thermostat,67,holidaytemp,holiday temperature,uint8 (>=5<=30),C,true,number.thermostat_hc1_holiday_temperature,number.thermostat_hc1_holidaytemp +RC30,thermostat,67,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp +RC30,thermostat,67,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp RC30,thermostat,67,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode RC30,thermostat,67,holidaymode,holiday mode,boolean, ,false,binary_sensor.thermostat_hc1_holiday_mode,binary_sensor.thermostat_hc1_holidaymode -RC30,thermostat,67,nofrosttemp,nofrost temperature,int (>=-20<=10),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp +RC30,thermostat,67,nofrosttemp,nofrost temperature,int8 (>=-20<=10),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp RC30,thermostat,67,nofrostmode,nofrost mode,enum [off\|outdoor\|room], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode -RC30,thermostat,67,roominfluence,room influence,uint (>=0<=10),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence -RC30,thermostat,67,minflowtemp,min flow temperature,uint (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp -RC30,thermostat,67,maxflowtemp,max flow temperature,uint (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp -RC30,thermostat,67,flowtempoffset,flow temperature offset for mixer,uint (>=0<=20),C,true,number.thermostat_hc1_flow_temperature_offset_for_mixer,number.thermostat_hc1_flowtempoffset +RC30,thermostat,67,roominfluence,room influence,uint8 (>=0<=10),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence +RC30,thermostat,67,minflowtemp,min flow temperature,uint8 (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp +RC30,thermostat,67,maxflowtemp,max flow temperature,uint8 (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp +RC30,thermostat,67,flowtempoffset,flow temperature offset for mixer,uint8 (>=0<=20),C,true,number.thermostat_hc1_flow_temperature_offset_for_mixer,number.thermostat_hc1_flowtempoffset RC30,thermostat,67,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype RC30,thermostat,67,reducemode,reduce mode,enum [nofrost\|reduce\|room\|outdoor], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode RC30,thermostat,67,controlmode,control mode,enum [outdoor\|room], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode @@ -3352,142 +3485,142 @@ RC30,thermostat,67,control,control device,enum [off\|RC20\|RC3x], ,true,select.t RC30,thermostat,67,holidays,holiday dates,string, ,true,sensor.thermostat_hc1_holiday_dates,sensor.thermostat_hc1_holidays RC30,thermostat,67,vacations,vacation dates,string, ,true,sensor.thermostat_hc1_vacation_dates,sensor.thermostat_hc1_vacations RC30,thermostat,67,program,program,enum [own 1\|family\|morning\|evening\|am\|pm\|midday\|singles\|seniors\|new\|own 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program -RC30,thermostat,67,pause,pause time,uint (>=0<=99),hours,true,number.thermostat_hc1_pause_time,number.thermostat_hc1_pause -RC30,thermostat,67,party,party time,uint (>=0<=99),hours,true,number.thermostat_hc1_party_time,number.thermostat_hc1_party -RC30,thermostat,67,tempautotemp,temporary set temperature automode,uint (>=0<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp -RC30,thermostat,67,noreducetemp,no reduce below temperature,int (>=-31<=10),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp -RC30,thermostat,67,reducetemp,off/reduce switch temperature,int (>=-20<=10),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp -RC30,thermostat,67,vacreducetemp,vacations off/reduce switch temperature,int (>=-20<=10),C,true,number.thermostat_hc1_vacations_off/reduce_switch_temperature,number.thermostat_hc1_vacreducetemp +RC30,thermostat,67,pause,pause time,uint8 (>=0<=99),hours,true,number.thermostat_hc1_pause_time,number.thermostat_hc1_pause +RC30,thermostat,67,party,party time,uint8 (>=0<=99),hours,true,number.thermostat_hc1_party_time,number.thermostat_hc1_party +RC30,thermostat,67,tempautotemp,temporary set temperature automode,uint8 (>=0<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp +RC30,thermostat,67,noreducetemp,no reduce below temperature,int8 (>=-31<=10),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp +RC30,thermostat,67,reducetemp,off/reduce switch temperature,int8 (>=-20<=10),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp +RC30,thermostat,67,vacreducetemp,vacations off/reduce switch temperature,int8 (>=-20<=10),C,true,number.thermostat_hc1_vacations_off/reduce_switch_temperature,number.thermostat_hc1_vacreducetemp RC30,thermostat,67,vacreducemode,vacations reduce mode,enum [nofrost\|reduce\|room\|outdoor], ,true,select.thermostat_hc1_vacations_reduce_mode,select.thermostat_hc1_vacreducemode -RC30,thermostat,67,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp -RC30,thermostat,67,wwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_wwprio +RC30,thermostat,67,remotetemp,room temperature from remote,int16 (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp +RC30,thermostat,67,dhwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_dhwprio RC30,thermostat,67,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization RC30,thermostat,67,switchtime1,own1 program switchtime,string, ,true,sensor.thermostat_hc1_own1_program_switchtime,sensor.thermostat_hc1_switchtime1 RC30,thermostat,67,switchtime2,own2 program switchtime,string, ,true,sensor.thermostat_hc1_own2_program_switchtime,sensor.thermostat_hc1_switchtime2 +RC30,thermostat,67,mode,mode,enum [off\|on\|auto], ,true,select.thermostat_dhw_mode,select.thermostat_dhw_mode +RC30,thermostat,67,circmode,circulation pump mode,enum [off\|on\|auto], ,true,select.thermostat_dhw_circulation_pump_mode,select.thermostat_dhw_circmode +RC30,thermostat,67,progmode,program,enum [std prog\|own prog], ,true,select.thermostat_dhw_program,select.thermostat_dhw_progmode +RC30,thermostat,67,circprog,circulation program,enum [std prog\|own prog], ,true,select.thermostat_dhw_circulation_program,select.thermostat_dhw_circprog +RC30,thermostat,67,disinfecting,disinfecting,boolean, ,true,switch.thermostat_dhw_disinfecting,switch.thermostat_dhw_disinfecting +RC30,thermostat,67,disinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_dhw_disinfection_day,select.thermostat_dhw_disinfectday +RC30,thermostat,67,disinfecthour,disinfection hour,uint8 (>=0<=23), ,true,number.thermostat_dhw_disinfection_hour,number.thermostat_dhw_disinfecthour +RC30,thermostat,67,maxtemp,maximum temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_maximum_temperature,number.thermostat_dhw_maxtemp +RC30,thermostat,67,onetimekey,one time key function,boolean, ,true,switch.thermostat_dhw_one_time_key_function,switch.thermostat_dhw_onetimekey +RC30,thermostat,67,switchtime,program switchtime,string, ,true,sensor.thermostat_dhw_program_switchtime,sensor.thermostat_dhw_switchtime +RC30,thermostat,67,circswitchtime,circulation program switchtime,string, ,true,sensor.thermostat_dhw_circulation_program_switchtime,sensor.thermostat_dhw_circswitchtime +RC30,thermostat,67,holidays,holiday dates,string, ,true,sensor.thermostat_dhw_holiday_dates,sensor.thermostat_dhw_holidays +RC30,thermostat,67,vacations,vacation dates,string, ,true,sensor.thermostat_dhw_vacation_dates,sensor.thermostat_dhw_vacations RC20/Moduline 300,thermostat,77,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode RC20/Moduline 300,thermostat,77,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode RC20/Moduline 300,thermostat,77,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime -RC20/Moduline 300,thermostat,77,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -RC20/Moduline 300,thermostat,77,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +RC20/Moduline 300,thermostat,77,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +RC20/Moduline 300,thermostat,77,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp RC20/Moduline 300,thermostat,77,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate RC20/Moduline 300,thermostat,77,mode,mode,enum [off\|manual\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode -RC20/Moduline 300,thermostat,77,manualtemp,manual temperature,uint (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp -RC20/Moduline 300,thermostat,77,offtemp,temperature when mode is off,uint (>=0<=127),C,true,number.thermostat_hc1_temperature_when_mode_is_off,number.thermostat_hc1_offtemp -RC20/Moduline 300,thermostat,77,daytemp2,day temperature T2,uint (>=0<=127),C,true,number.thermostat_hc1_day_temperature_T2,number.thermostat_hc1_daytemp2 -RC20/Moduline 300,thermostat,77,daytemp3,day temperature T3,uint (>=0<=127),C,true,number.thermostat_hc1_day_temperature_T3,number.thermostat_hc1_daytemp3 -RC20/Moduline 300,thermostat,77,daytemp4,day temperature T4,uint (>=0<=127),C,true,number.thermostat_hc1_day_temperature_T4,number.thermostat_hc1_daytemp4 -RC20/Moduline 300,thermostat,77,nighttemp,night temperature T1,uint (>=0<=127),C,true,number.thermostat_hc1_night_temperature_T1,number.thermostat_hc1_nighttemp +RC20/Moduline 300,thermostat,77,manualtemp,manual temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp +RC20/Moduline 300,thermostat,77,offtemp,temperature when mode is off,uint8 (>=0<=127),C,true,number.thermostat_hc1_temperature_when_mode_is_off,number.thermostat_hc1_offtemp +RC20/Moduline 300,thermostat,77,daytemp2,day temperature T2,uint8 (>=0<=127),C,true,number.thermostat_hc1_day_temperature_T2,number.thermostat_hc1_daytemp2 +RC20/Moduline 300,thermostat,77,daytemp3,day temperature T3,uint8 (>=0<=127),C,true,number.thermostat_hc1_day_temperature_T3,number.thermostat_hc1_daytemp3 +RC20/Moduline 300,thermostat,77,daytemp4,day temperature T4,uint8 (>=0<=127),C,true,number.thermostat_hc1_day_temperature_T4,number.thermostat_hc1_daytemp4 +RC20/Moduline 300,thermostat,77,nighttemp,night temperature T1,uint8 (>=0<=127),C,true,number.thermostat_hc1_night_temperature_T1,number.thermostat_hc1_nighttemp RC20/Moduline 300,thermostat,77,switchtime,program switchtime,string, ,true,sensor.thermostat_hc1_program_switchtime,sensor.thermostat_hc1_switchtime Moduline 400,thermostat,78,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode Moduline 400,thermostat,78,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode Moduline 400,thermostat,78,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime -Moduline 400,thermostat,78,clockoffset,clock offset,int (>=-126<=126),seconds,true,number.thermostat_clock_offset,number.thermostat_clockoffset +Moduline 400,thermostat,78,clockoffset,clock offset,int8 (>=-126<=126),seconds,true,number.thermostat_clock_offset,number.thermostat_clockoffset Moduline 400,thermostat,78,autodst,automatic change daylight saving time,boolean, ,true,switch.thermostat_automatic_change_daylight_saving_time,switch.thermostat_autodst Moduline 400,thermostat,78,language,language,enum [german\|dutch], ,true,select.thermostat_language,select.thermostat_language Moduline 400,thermostat,78,backlight,key backlight,boolean, ,true,switch.thermostat_key_backlight,switch.thermostat_backlight -Moduline 400,thermostat,78,brightness,screen brightness,int (>=-15<=15), ,true,number.thermostat_screen_brightness,number.thermostat_brightness -Moduline 400,thermostat,78,mixingvalves,mixing valves,uint (>=0<=2), ,true,number.thermostat_mixing_valves,number.thermostat_mixingvalves +Moduline 400,thermostat,78,brightness,screen brightness,int8 (>=-15<=15), ,true,number.thermostat_screen_brightness,number.thermostat_brightness +Moduline 400,thermostat,78,mixingvalves,mixing valves,uint8 (>=0<=2), ,true,number.thermostat_mixing_valves,number.thermostat_mixingvalves Moduline 400,thermostat,78,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building Moduline 400,thermostat,78,heatingpid,heating PID,enum [fast\|medium\|slow], ,true,select.thermostat_heating_PID,select.thermostat_heatingpid Moduline 400,thermostat,78,preheating,preheating in the clock program,boolean, ,true,switch.thermostat_preheating_in_the_clock_program,switch.thermostat_preheating -Moduline 400,thermostat,78,intoffset,internal temperature offset,int (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset -Moduline 400,thermostat,78,wwmode,mode,enum [on\|off\|auto], ,true,select.thermostat_mode,select.thermostat_wwmode -Moduline 400,thermostat,78,wwwhenmodeoff,when thermostat mode off,boolean, ,true,switch.thermostat_when_thermostat_mode_off,switch.thermostat_wwwhenmodeoff -Moduline 400,thermostat,78,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_disinfecting,switch.thermostat_wwdisinfecting -Moduline 400,thermostat,78,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_disinfection_day,select.thermostat_wwdisinfectday -Moduline 400,thermostat,78,wwdisinfecthour,disinfection hour,uint (>=0<=23), ,true,number.thermostat_disinfection_hour,number.thermostat_wwdisinfecthour -Moduline 400,thermostat,78,wwholidays,holiday dates,string, ,true,sensor.thermostat_holiday_dates,sensor.thermostat_wwholidays -Moduline 400,thermostat,78,wwvacations,vacation dates,string, ,true,sensor.thermostat_vacation_dates,sensor.thermostat_wwvacations -Moduline 400,thermostat,78,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -Moduline 400,thermostat,78,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +Moduline 400,thermostat,78,intoffset,internal temperature offset,int8 (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset +Moduline 400,thermostat,78,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +Moduline 400,thermostat,78,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp Moduline 400,thermostat,78,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate Moduline 400,thermostat,78,mode,mode,enum [off\|manual\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode Moduline 400,thermostat,78,holidays,holiday dates,string, ,true,sensor.thermostat_hc1_holiday_dates,sensor.thermostat_hc1_holidays Moduline 400,thermostat,78,vacations,vacation dates,string, ,true,sensor.thermostat_hc1_vacation_dates,sensor.thermostat_hc1_vacations Moduline 400,thermostat,78,program,program,enum [own 1\|family\|morning\|evening\|am\|pm\|midday\|singles\|seniors\|new\|own 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program -Moduline 400,thermostat,78,pause,pause time,uint (>=0<=254),hours,true,number.thermostat_hc1_pause_time,number.thermostat_hc1_pause -Moduline 400,thermostat,78,party,party time,uint (>=0<=254),hours,true,number.thermostat_hc1_party_time,number.thermostat_hc1_party +Moduline 400,thermostat,78,pause,pause time,uint8 (>=0<=254),hours,true,number.thermostat_hc1_pause_time,number.thermostat_hc1_pause +Moduline 400,thermostat,78,party,party time,uint8 (>=0<=254),hours,true,number.thermostat_hc1_party_time,number.thermostat_hc1_party Moduline 400,thermostat,78,switchtime1,own1 program switchtime,string, ,true,sensor.thermostat_hc1_own1_program_switchtime,sensor.thermostat_hc1_switchtime1 Moduline 400,thermostat,78,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype Moduline 400,thermostat,78,controlmode,control mode,enum [outdoor\|room], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode -Moduline 400,thermostat,78,holidaytemp,holiday temperature,uint (>=0<=127),C,true,number.thermostat_hc1_holiday_temperature,number.thermostat_hc1_holidaytemp -Moduline 400,thermostat,78,nighttemp,night temperature T1,uint (>=0<=127),C,true,number.thermostat_hc1_night_temperature_T1,number.thermostat_hc1_nighttemp -Moduline 400,thermostat,78,daytemp2,day temperature T2,uint (>=0<=127),C,true,number.thermostat_hc1_day_temperature_T2,number.thermostat_hc1_daytemp2 -Moduline 400,thermostat,78,daytemp3,day temperature T3,uint (>=0<=127),C,true,number.thermostat_hc1_day_temperature_T3,number.thermostat_hc1_daytemp3 -Moduline 400,thermostat,78,daytemp4,day temperature T4,uint (>=0<=127),C,true,number.thermostat_hc1_day_temperature_T4,number.thermostat_hc1_daytemp4 -Moduline 400,thermostat,78,manualtemp,manual temperature,uint (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp -Moduline 400,thermostat,78,offtemp,temperature when mode is off,uint (>=0<=127),C,true,number.thermostat_hc1_temperature_when_mode_is_off,number.thermostat_hc1_offtemp +Moduline 400,thermostat,78,holidaytemp,holiday temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_holiday_temperature,number.thermostat_hc1_holidaytemp +Moduline 400,thermostat,78,nighttemp,night temperature T1,uint8 (>=0<=127),C,true,number.thermostat_hc1_night_temperature_T1,number.thermostat_hc1_nighttemp +Moduline 400,thermostat,78,daytemp2,day temperature T2,uint8 (>=0<=127),C,true,number.thermostat_hc1_day_temperature_T2,number.thermostat_hc1_daytemp2 +Moduline 400,thermostat,78,daytemp3,day temperature T3,uint8 (>=0<=127),C,true,number.thermostat_hc1_day_temperature_T3,number.thermostat_hc1_daytemp3 +Moduline 400,thermostat,78,daytemp4,day temperature T4,uint8 (>=0<=127),C,true,number.thermostat_hc1_day_temperature_T4,number.thermostat_hc1_daytemp4 +Moduline 400,thermostat,78,manualtemp,manual temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp +Moduline 400,thermostat,78,offtemp,temperature when mode is off,uint8 (>=0<=127),C,true,number.thermostat_hc1_temperature_when_mode_is_off,number.thermostat_hc1_offtemp +Moduline 400,thermostat,78,mode,mode,enum [on\|off\|auto], ,true,select.thermostat_dhw_mode,select.thermostat_dhw_mode +Moduline 400,thermostat,78,whenmodeoff,when thermostat mode off,boolean, ,true,switch.thermostat_dhw_when_thermostat_mode_off,switch.thermostat_dhw_whenmodeoff +Moduline 400,thermostat,78,disinfecting,disinfecting,boolean, ,true,switch.thermostat_dhw_disinfecting,switch.thermostat_dhw_disinfecting +Moduline 400,thermostat,78,disinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_dhw_disinfection_day,select.thermostat_dhw_disinfectday +Moduline 400,thermostat,78,disinfecthour,disinfection hour,uint8 (>=0<=23), ,true,number.thermostat_dhw_disinfection_hour,number.thermostat_dhw_disinfecthour +Moduline 400,thermostat,78,holidays,holiday dates,string, ,true,sensor.thermostat_dhw_holiday_dates,sensor.thermostat_dhw_holidays +Moduline 400,thermostat,78,vacations,vacation dates,string, ,true,sensor.thermostat_dhw_vacation_dates,sensor.thermostat_dhw_vacations RC10/Moduline 100,thermostat,79,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode RC10/Moduline 100,thermostat,79,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode -RC10/Moduline 100,thermostat,79,intoffset,internal temperature offset,int (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset +RC10/Moduline 100,thermostat,79,intoffset,internal temperature offset,int8 (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset RC10/Moduline 100,thermostat,79,heatingpid,heating PID,enum [fast\|medium\|slow], ,true,select.thermostat_heating_PID,select.thermostat_heatingpid RC10/Moduline 100,thermostat,79,backlight,key backlight,boolean, ,true,switch.thermostat_key_backlight,switch.thermostat_backlight -RC10/Moduline 100,thermostat,79,wwmode,mode,enum [on\|off\|auto], ,true,select.thermostat_mode,select.thermostat_wwmode -RC10/Moduline 100,thermostat,79,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -RC10/Moduline 100,thermostat,79,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +RC10/Moduline 100,thermostat,79,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +RC10/Moduline 100,thermostat,79,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp RC10/Moduline 100,thermostat,79,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate RC10/Moduline 100,thermostat,79,mode,mode,enum [nofrost\|night\|day], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode -RC10/Moduline 100,thermostat,79,daytemp,day temperature,uint (>=0<=127),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp -RC10/Moduline 100,thermostat,79,nighttemp,night temperature,uint (>=0<=127),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp -RC10/Moduline 100,thermostat,79,reducehours,duration for nighttemp,uint (>=0<=254),hours,true,number.thermostat_hc1_duration_for_nighttemp,number.thermostat_hc1_reducehours -RC10/Moduline 100,thermostat,79,reduceminutes,remaining time for nightmode,ushort (>=0<=31999),minutes,false,sensor.thermostat_hc1_remaining_time_for_nightmode,sensor.thermostat_hc1_reduceminutes +RC10/Moduline 100,thermostat,79,daytemp,day temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp +RC10/Moduline 100,thermostat,79,nighttemp,night temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp +RC10/Moduline 100,thermostat,79,reducehours,duration for nighttemp,uint8 (>=0<=254),hours,true,number.thermostat_hc1_duration_for_nighttemp,number.thermostat_hc1_reducehours +RC10/Moduline 100,thermostat,79,reduceminutes,remaining time for nightmode,uint16 (>=0<=31999),minutes,false,sensor.thermostat_hc1_remaining_time_for_nightmode,sensor.thermostat_hc1_reduceminutes +RC10/Moduline 100,thermostat,79,mode,mode,enum [on\|off\|auto], ,true,select.thermostat_dhw_mode,select.thermostat_dhw_mode Moduline 200,thermostat,80,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode Moduline 200,thermostat,80,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode -Moduline 200,thermostat,80,intoffset,internal temperature offset,int (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset +Moduline 200,thermostat,80,intoffset,internal temperature offset,int8 (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset Moduline 200,thermostat,80,heatingpid,heating PID,enum [fast\|medium\|slow], ,true,select.thermostat_heating_PID,select.thermostat_heatingpid Moduline 200,thermostat,80,backlight,key backlight,boolean, ,true,switch.thermostat_key_backlight,switch.thermostat_backlight -Moduline 200,thermostat,80,wwmode,mode,enum [on\|off\|auto], ,true,select.thermostat_mode,select.thermostat_wwmode -Moduline 200,thermostat,80,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -Moduline 200,thermostat,80,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +Moduline 200,thermostat,80,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +Moduline 200,thermostat,80,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp Moduline 200,thermostat,80,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate Moduline 200,thermostat,80,mode,mode,enum [nofrost\|night\|day], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode -Moduline 200,thermostat,80,daytemp,day temperature,uint (>=0<=127),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp -Moduline 200,thermostat,80,nighttemp,night temperature,uint (>=0<=127),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp -Moduline 200,thermostat,80,reducehours,duration for nighttemp,uint (>=0<=254),hours,true,number.thermostat_hc1_duration_for_nighttemp,number.thermostat_hc1_reducehours -Moduline 200,thermostat,80,reduceminutes,remaining time for nightmode,ushort (>=0<=31999),minutes,false,sensor.thermostat_hc1_remaining_time_for_nightmode,sensor.thermostat_hc1_reduceminutes +Moduline 200,thermostat,80,daytemp,day temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp +Moduline 200,thermostat,80,nighttemp,night temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp +Moduline 200,thermostat,80,reducehours,duration for nighttemp,uint8 (>=0<=254),hours,true,number.thermostat_hc1_duration_for_nighttemp,number.thermostat_hc1_reducehours +Moduline 200,thermostat,80,reduceminutes,remaining time for nightmode,uint16 (>=0<=31999),minutes,false,sensor.thermostat_hc1_remaining_time_for_nightmode,sensor.thermostat_hc1_reduceminutes +Moduline 200,thermostat,80,mode,mode,enum [on\|off\|auto], ,true,select.thermostat_dhw_mode,select.thermostat_dhw_mode RC35,thermostat,86,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode RC35,thermostat,86,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode RC35,thermostat,86,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime -RC35,thermostat,86,intoffset,internal temperature offset,int (>=-5<=5),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset -RC35,thermostat,86,minexttemp,minimal external temperature,int (>=-30<=0),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp -RC35,thermostat,86,inttemp1,temperature sensor 1,short (>=-3199<=3199),C,false,sensor.thermostat_temperature_sensor_1,sensor.thermostat_inttemp1 -RC35,thermostat,86,inttemp2,temperature sensor 2,short (>=-3199<=3199),C,false,sensor.thermostat_temperature_sensor_2,sensor.thermostat_inttemp2 +RC35,thermostat,86,intoffset,internal temperature offset,int8 (>=-5<=5),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset +RC35,thermostat,86,minexttemp,minimal external temperature,int8 (>=-30<=0),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp +RC35,thermostat,86,inttemp1,temperature sensor 1,int16 (>=-3199<=3199),C,false,sensor.thermostat_temperature_sensor_1,sensor.thermostat_inttemp1 +RC35,thermostat,86,inttemp2,temperature sensor 2,int16 (>=-3199<=3199),C,false,sensor.thermostat_temperature_sensor_2,sensor.thermostat_inttemp2 RC35,thermostat,86,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping -RC35,thermostat,86,dampedoutdoortemp,damped outdoor temperature,int (>=-126<=126),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp +RC35,thermostat,86,dampedoutdoortemp,damped outdoor temperature,int8 (>=-126<=126),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp RC35,thermostat,86,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building -RC35,thermostat,86,wwmode,mode,enum [off\|on\|auto], ,true,select.thermostat_mode,select.thermostat_wwmode -RC35,thermostat,86,wwcircmode,circulation pump mode,enum [off\|on\|auto], ,true,select.thermostat_circulation_pump_mode,select.thermostat_wwcircmode -RC35,thermostat,86,wwprogmode,program,enum [std prog\|own prog], ,true,select.thermostat_program,select.thermostat_wwprogmode -RC35,thermostat,86,wwcircprog,circulation program,enum [std prog\|own prog], ,true,select.thermostat_circulation_program,select.thermostat_wwcircprog -RC35,thermostat,86,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_disinfecting,switch.thermostat_wwdisinfecting -RC35,thermostat,86,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_disinfection_day,select.thermostat_wwdisinfectday -RC35,thermostat,86,wwdisinfecthour,disinfection hour,uint (>=0<=23), ,true,number.thermostat_disinfection_hour,number.thermostat_wwdisinfecthour -RC35,thermostat,86,wwmaxtemp,maximum temperature,uint (>=60<=80),C,true,number.thermostat_maximum_temperature,number.thermostat_wwmaxtemp -RC35,thermostat,86,wwonetimekey,one time key function,boolean, ,true,switch.thermostat_one_time_key_function,switch.thermostat_wwonetimekey -RC35,thermostat,86,wwswitchtime,program switchtime,string, ,true,sensor.thermostat_program_switchtime,sensor.thermostat_wwswitchtime -RC35,thermostat,86,wwcircswitchtime,circulation program switchtime,string, ,true,sensor.thermostat_circulation_program_switchtime,sensor.thermostat_wwcircswitchtime -RC35,thermostat,86,wwholidays,holiday dates,string, ,true,sensor.thermostat_holiday_dates,sensor.thermostat_wwholidays -RC35,thermostat,86,wwvacations,vacation dates,string, ,true,sensor.thermostat_vacation_dates,sensor.thermostat_wwvacations -RC35,thermostat,86,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -RC35,thermostat,86,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +RC35,thermostat,86,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +RC35,thermostat,86,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp RC35,thermostat,86,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate RC35,thermostat,86,mode,mode,enum [night\|day\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode RC35,thermostat,86,modetype,mode type,enum [night\|day], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype -RC35,thermostat,86,daytemp,day temperature,uint (>=10<=30),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp -RC35,thermostat,86,nighttemp,night temperature,uint (>=10<=30),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp -RC35,thermostat,86,designtemp,design temperature,uint (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp -RC35,thermostat,86,offsettemp,offset temperature,int (>=-5<=5),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp -RC35,thermostat,86,holidaytemp,holiday temperature,uint (>=5<=30),C,true,number.thermostat_hc1_holiday_temperature,number.thermostat_hc1_holidaytemp -RC35,thermostat,86,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp -RC35,thermostat,86,summertemp,summer temperature,uint (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp +RC35,thermostat,86,daytemp,day temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp +RC35,thermostat,86,nighttemp,night temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp +RC35,thermostat,86,designtemp,design temperature,uint8 (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp +RC35,thermostat,86,offsettemp,offset temperature,int8 (>=-5<=5),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp +RC35,thermostat,86,holidaytemp,holiday temperature,uint8 (>=5<=30),C,true,number.thermostat_hc1_holiday_temperature,number.thermostat_hc1_holidaytemp +RC35,thermostat,86,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp +RC35,thermostat,86,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp RC35,thermostat,86,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode RC35,thermostat,86,holidaymode,holiday mode,boolean, ,false,binary_sensor.thermostat_hc1_holiday_mode,binary_sensor.thermostat_hc1_holidaymode -RC35,thermostat,86,nofrosttemp,nofrost temperature,int (>=-20<=10),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp +RC35,thermostat,86,nofrosttemp,nofrost temperature,int8 (>=-20<=10),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp RC35,thermostat,86,nofrostmode,nofrost mode,enum [off\|outdoor\|room], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode -RC35,thermostat,86,roominfluence,room influence,uint (>=0<=10),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence -RC35,thermostat,86,minflowtemp,min flow temperature,uint (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp -RC35,thermostat,86,maxflowtemp,max flow temperature,uint (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp -RC35,thermostat,86,flowtempoffset,flow temperature offset for mixer,uint (>=0<=20),C,true,number.thermostat_hc1_flow_temperature_offset_for_mixer,number.thermostat_hc1_flowtempoffset +RC35,thermostat,86,roominfluence,room influence,uint8 (>=0<=10),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence +RC35,thermostat,86,minflowtemp,min flow temperature,uint8 (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp +RC35,thermostat,86,maxflowtemp,max flow temperature,uint8 (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp +RC35,thermostat,86,flowtempoffset,flow temperature offset for mixer,uint8 (>=0<=20),C,true,number.thermostat_hc1_flow_temperature_offset_for_mixer,number.thermostat_hc1_flowtempoffset RC35,thermostat,86,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype RC35,thermostat,86,reducemode,reduce mode,enum [nofrost\|reduce\|room\|outdoor], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode RC35,thermostat,86,controlmode,control mode,enum [outdoor\|room], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode @@ -3495,136 +3628,127 @@ RC35,thermostat,86,control,control device,enum [off\|RC20\|RC3x], ,true,select.t RC35,thermostat,86,holidays,holiday dates,string, ,true,sensor.thermostat_hc1_holiday_dates,sensor.thermostat_hc1_holidays RC35,thermostat,86,vacations,vacation dates,string, ,true,sensor.thermostat_hc1_vacation_dates,sensor.thermostat_hc1_vacations RC35,thermostat,86,program,program,enum [own 1\|family\|morning\|evening\|am\|pm\|midday\|singles\|seniors\|new\|own 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program -RC35,thermostat,86,pause,pause time,uint (>=0<=99),hours,true,number.thermostat_hc1_pause_time,number.thermostat_hc1_pause -RC35,thermostat,86,party,party time,uint (>=0<=99),hours,true,number.thermostat_hc1_party_time,number.thermostat_hc1_party -RC35,thermostat,86,tempautotemp,temporary set temperature automode,uint (>=0<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp -RC35,thermostat,86,noreducetemp,no reduce below temperature,int (>=-31<=10),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp -RC35,thermostat,86,reducetemp,off/reduce switch temperature,int (>=-20<=10),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp -RC35,thermostat,86,vacreducetemp,vacations off/reduce switch temperature,int (>=-20<=10),C,true,number.thermostat_hc1_vacations_off/reduce_switch_temperature,number.thermostat_hc1_vacreducetemp +RC35,thermostat,86,pause,pause time,uint8 (>=0<=99),hours,true,number.thermostat_hc1_pause_time,number.thermostat_hc1_pause +RC35,thermostat,86,party,party time,uint8 (>=0<=99),hours,true,number.thermostat_hc1_party_time,number.thermostat_hc1_party +RC35,thermostat,86,tempautotemp,temporary set temperature automode,uint8 (>=0<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp +RC35,thermostat,86,noreducetemp,no reduce below temperature,int8 (>=-31<=10),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp +RC35,thermostat,86,reducetemp,off/reduce switch temperature,int8 (>=-20<=10),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp +RC35,thermostat,86,vacreducetemp,vacations off/reduce switch temperature,int8 (>=-20<=10),C,true,number.thermostat_hc1_vacations_off/reduce_switch_temperature,number.thermostat_hc1_vacreducetemp RC35,thermostat,86,vacreducemode,vacations reduce mode,enum [nofrost\|reduce\|room\|outdoor], ,true,select.thermostat_hc1_vacations_reduce_mode,select.thermostat_hc1_vacreducemode -RC35,thermostat,86,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp -RC35,thermostat,86,wwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_wwprio +RC35,thermostat,86,remotetemp,room temperature from remote,int16 (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp +RC35,thermostat,86,dhwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_dhwprio RC35,thermostat,86,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization RC35,thermostat,86,switchtime1,own1 program switchtime,string, ,true,sensor.thermostat_hc1_own1_program_switchtime,sensor.thermostat_hc1_switchtime1 RC35,thermostat,86,switchtime2,own2 program switchtime,string, ,true,sensor.thermostat_hc1_own2_program_switchtime,sensor.thermostat_hc1_switchtime2 +RC35,thermostat,86,mode,mode,enum [off\|on\|auto], ,true,select.thermostat_dhw_mode,select.thermostat_dhw_mode +RC35,thermostat,86,circmode,circulation pump mode,enum [off\|on\|auto], ,true,select.thermostat_dhw_circulation_pump_mode,select.thermostat_dhw_circmode +RC35,thermostat,86,progmode,program,enum [std prog\|own prog], ,true,select.thermostat_dhw_program,select.thermostat_dhw_progmode +RC35,thermostat,86,circprog,circulation program,enum [std prog\|own prog], ,true,select.thermostat_dhw_circulation_program,select.thermostat_dhw_circprog +RC35,thermostat,86,disinfecting,disinfecting,boolean, ,true,switch.thermostat_dhw_disinfecting,switch.thermostat_dhw_disinfecting +RC35,thermostat,86,disinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_dhw_disinfection_day,select.thermostat_dhw_disinfectday +RC35,thermostat,86,disinfecthour,disinfection hour,uint8 (>=0<=23), ,true,number.thermostat_dhw_disinfection_hour,number.thermostat_dhw_disinfecthour +RC35,thermostat,86,maxtemp,maximum temperature,uint8 (>=60<=80),C,true,number.thermostat_dhw_maximum_temperature,number.thermostat_dhw_maxtemp +RC35,thermostat,86,onetimekey,one time key function,boolean, ,true,switch.thermostat_dhw_one_time_key_function,switch.thermostat_dhw_onetimekey +RC35,thermostat,86,switchtime,program switchtime,string, ,true,sensor.thermostat_dhw_program_switchtime,sensor.thermostat_dhw_switchtime +RC35,thermostat,86,circswitchtime,circulation program switchtime,string, ,true,sensor.thermostat_dhw_circulation_program_switchtime,sensor.thermostat_dhw_circswitchtime +RC35,thermostat,86,holidays,holiday dates,string, ,true,sensor.thermostat_dhw_holiday_dates,sensor.thermostat_dhw_holidays +RC35,thermostat,86,vacations,vacation dates,string, ,true,sensor.thermostat_dhw_vacation_dates,sensor.thermostat_dhw_vacations RC10/Moduline 100,thermostat,90,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode RC10/Moduline 100,thermostat,90,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode RC10/Moduline 100,thermostat,90,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime -RC10/Moduline 100,thermostat,90,minexttemp,minimal external temperature,int (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp -RC10/Moduline 100,thermostat,90,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -RC10/Moduline 100,thermostat,90,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +RC10/Moduline 100,thermostat,90,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp +RC10/Moduline 100,thermostat,90,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +RC10/Moduline 100,thermostat,90,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp RC10/Moduline 100,thermostat,90,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate RC10/Moduline 100,thermostat,90,mode,mode,enum [night\|day\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode RC10/Moduline 100,thermostat,90,modetype,mode type,enum [night\|day], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype -RC10/Moduline 100,thermostat,90,daytemp,day temperature,uint (>=0<=127),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp -RC10/Moduline 100,thermostat,90,nighttemp,night temperature,uint (>=0<=127),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp +RC10/Moduline 100,thermostat,90,daytemp,day temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp +RC10/Moduline 100,thermostat,90,nighttemp,night temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp RC10/Moduline 100,thermostat,90,program,program,enum [family\|morning\|evening\|am\|pm\|midday\|singles\|seniors], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program -RC10/Moduline 100,thermostat,90,minflowtemp,min flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp -RC10/Moduline 100,thermostat,90,maxflowtemp,max flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp -RC10/Moduline 100,thermostat,90,tempautotemp,temporary set temperature automode,uint (>=0<=127),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp +RC10/Moduline 100,thermostat,90,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp +RC10/Moduline 100,thermostat,90,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp +RC10/Moduline 100,thermostat,90,tempautotemp,temporary set temperature automode,uint8 (>=0<=127),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp RC10/Moduline 100,thermostat,90,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype -RC10/Moduline 100,thermostat,90,summertemp,summer temperature,uint (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp +RC10/Moduline 100,thermostat,90,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp RC10/Moduline 100,thermostat,90,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode -RC10/Moduline 100,thermostat,90,remotetemp,room temperature from remote,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp +RC10/Moduline 100,thermostat,90,remotetemp,room temperature from remote,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp RC20RF,thermostat,93,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode RC20RF,thermostat,93,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode RC20RF,thermostat,93,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime -RC20RF,thermostat,93,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -RC20RF,thermostat,93,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +RC20RF,thermostat,93,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +RC20RF,thermostat,93,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp RC20RF,thermostat,93,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate RC20RF,thermostat,93,mode,mode,enum [off\|manual\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode -RC20RF,thermostat,93,manualtemp,manual temperature,uint (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp -RC20RF,thermostat,93,offtemp,temperature when mode is off,uint (>=0<=127),C,true,number.thermostat_hc1_temperature_when_mode_is_off,number.thermostat_hc1_offtemp -RC20RF,thermostat,93,daytemp2,day temperature T2,uint (>=0<=127),C,true,number.thermostat_hc1_day_temperature_T2,number.thermostat_hc1_daytemp2 -RC20RF,thermostat,93,daytemp3,day temperature T3,uint (>=0<=127),C,true,number.thermostat_hc1_day_temperature_T3,number.thermostat_hc1_daytemp3 -RC20RF,thermostat,93,daytemp4,day temperature T4,uint (>=0<=127),C,true,number.thermostat_hc1_day_temperature_T4,number.thermostat_hc1_daytemp4 -RC20RF,thermostat,93,nighttemp,night temperature T1,uint (>=0<=127),C,true,number.thermostat_hc1_night_temperature_T1,number.thermostat_hc1_nighttemp +RC20RF,thermostat,93,manualtemp,manual temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp +RC20RF,thermostat,93,offtemp,temperature when mode is off,uint8 (>=0<=127),C,true,number.thermostat_hc1_temperature_when_mode_is_off,number.thermostat_hc1_offtemp +RC20RF,thermostat,93,daytemp2,day temperature T2,uint8 (>=0<=127),C,true,number.thermostat_hc1_day_temperature_T2,number.thermostat_hc1_daytemp2 +RC20RF,thermostat,93,daytemp3,day temperature T3,uint8 (>=0<=127),C,true,number.thermostat_hc1_day_temperature_T3,number.thermostat_hc1_daytemp3 +RC20RF,thermostat,93,daytemp4,day temperature T4,uint8 (>=0<=127),C,true,number.thermostat_hc1_day_temperature_T4,number.thermostat_hc1_daytemp4 +RC20RF,thermostat,93,nighttemp,night temperature T1,uint8 (>=0<=127),C,true,number.thermostat_hc1_night_temperature_T1,number.thermostat_hc1_nighttemp RC20RF,thermostat,93,switchtime,program switchtime,string, ,true,sensor.thermostat_hc1_program_switchtime,sensor.thermostat_hc1_switchtime RFM20 Remote,thermostat,94,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode RFM20 Remote,thermostat,94,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode RFM20 Remote,thermostat,94,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime -RFM20 Remote,thermostat,94,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -RFM20 Remote,thermostat,94,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +RFM20 Remote,thermostat,94,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +RFM20 Remote,thermostat,94,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp RFM20 Remote,thermostat,94,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate RC25,thermostat,151,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode RC25,thermostat,151,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode RC25,thermostat,151,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime -RC25,thermostat,151,minexttemp,minimal external temperature,int (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp -RC25,thermostat,151,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -RC25,thermostat,151,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +RC25,thermostat,151,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp +RC25,thermostat,151,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +RC25,thermostat,151,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp RC25,thermostat,151,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate RC25,thermostat,151,mode,mode,enum [night\|day\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode RC25,thermostat,151,modetype,mode type,enum [night\|day], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype -RC25,thermostat,151,daytemp,day temperature,uint (>=0<=127),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp -RC25,thermostat,151,nighttemp,night temperature,uint (>=0<=127),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp +RC25,thermostat,151,daytemp,day temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp +RC25,thermostat,151,nighttemp,night temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp RC25,thermostat,151,program,program,enum [family\|morning\|evening\|am\|pm\|midday\|singles\|seniors], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program -RC25,thermostat,151,minflowtemp,min flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp -RC25,thermostat,151,maxflowtemp,max flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp -RC25,thermostat,151,tempautotemp,temporary set temperature automode,uint (>=0<=127),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp +RC25,thermostat,151,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp +RC25,thermostat,151,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp +RC25,thermostat,151,tempautotemp,temporary set temperature automode,uint8 (>=0<=127),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp RC25,thermostat,151,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype -RC25,thermostat,151,summertemp,summer temperature,uint (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp +RC25,thermostat,151,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp RC25,thermostat,151,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode RC200/CW100,thermostat,157,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode RC200/CW100,thermostat,157,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode RC200/CW100,thermostat,157,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime -RC200/CW100,thermostat,157,intoffset,internal temperature offset,int (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset +RC200/CW100,thermostat,157,intoffset,internal temperature offset,int8 (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset RC200/CW100,thermostat,157,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry -RC200/CW100,thermostat,157,dampedoutdoortemp,damped outdoor temperature,short (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp -RC200/CW100,thermostat,157,floordrytemp,floor drying temperature,uint (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp +RC200/CW100,thermostat,157,dampedoutdoortemp,damped outdoor temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp +RC200/CW100,thermostat,157,floordrytemp,floor drying temperature,uint8 (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp RC200/CW100,thermostat,157,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building -RC200/CW100,thermostat,157,minexttemp,minimal external temperature,int (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp +RC200/CW100,thermostat,157,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp RC200/CW100,thermostat,157,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping -RC200/CW100,thermostat,157,wwsettemp,set temperature,uint (>=0<=254),C,true,number.thermostat_set_temperature,number.thermostat_wwsettemp -RC200/CW100,thermostat,157,wwmode,mode,enum [off\|normal\|comfort\|auto\|own prog], ,true,select.thermostat_mode,select.thermostat_wwmode -RC200/CW100,thermostat,157,wwmode,mode,enum [off\|normal\|comfort\|auto\|own prog], ,true,select.thermostat_wwc2_mode,select.thermostat_wwc2_wwmode -RC200/CW100,thermostat,157,wwsettemplow,set low temperature,uint (>=0<=254),C,true,number.thermostat_set_low_temperature,number.thermostat_wwsettemplow -RC200/CW100,thermostat,157,wwcircmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_circulation_pump_mode,select.thermostat_wwcircmode -RC200/CW100,thermostat,157,wwchargeduration,charge duration,uint (>=0<=3810),minutes,true,number.thermostat_charge_duration,number.thermostat_wwchargeduration -RC200/CW100,thermostat,157,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge -RC200/CW100,thermostat,157,wwextra1,circuit 1 extra,uint (>=0<=254),C,false,sensor.thermostat_circuit_1_extra,sensor.thermostat_wwextra1 -RC200/CW100,thermostat,157,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_disinfecting,switch.thermostat_wwdisinfecting -RC200/CW100,thermostat,157,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_disinfection_day,select.thermostat_wwdisinfectday -RC200/CW100,thermostat,157,wwdisinfecttime,disinfection time,uint (>=0<=1431),minutes,true,number.thermostat_disinfection_time,number.thermostat_wwdisinfecttime -RC200/CW100,thermostat,157,wwdailyheating,daily heating,boolean, ,true,switch.thermostat_daily_heating,switch.thermostat_wwdailyheating -RC200/CW100,thermostat,157,wwdailyheattime,daily heating time,uint (>=0<=1431),minutes,true,number.thermostat_daily_heating_time,number.thermostat_wwdailyheattime -RC200/CW100,thermostat,157,wwcircmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_wwc2_circulation_pump_mode,select.thermostat_wwc2_wwcircmode -RC200/CW100,thermostat,157,wwchargeduration,charge duration,uint (>=0<=3810),minutes,true,number.thermostat_wwc2_charge_duration,number.thermostat_wwc2_wwchargeduration -RC200/CW100,thermostat,157,wwcharge,charge,boolean, ,true,switch.thermostat_wwc2_charge,switch.thermostat_wwc2_wwcharge -RC200/CW100,thermostat,157,wwextra2,circuit 2 extra,uint (>=0<=254),C,false,sensor.thermostat_wwc2_circuit_2_extra,sensor.thermostat_wwc2_wwextra2 -RC200/CW100,thermostat,157,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_wwc2_disinfecting,switch.thermostat_wwc2_wwdisinfecting -RC200/CW100,thermostat,157,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_wwc2_disinfection_day,select.thermostat_wwc2_wwdisinfectday -RC200/CW100,thermostat,157,wwdisinfecttime,disinfection time,uint (>=0<=1431),minutes,true,number.thermostat_wwc2_disinfection_time,number.thermostat_wwc2_wwdisinfecttime -RC200/CW100,thermostat,157,wwdailyheating,daily heating,boolean, ,true,switch.thermostat_wwc2_daily_heating,switch.thermostat_wwc2_wwdailyheating -RC200/CW100,thermostat,157,wwdailyheattime,daily heating time,uint (>=0<=1431),minutes,true,number.thermostat_wwc2_daily_heating_time,number.thermostat_wwc2_wwdailyheattime RC200/CW100,thermostat,157,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy -RC200/CW100,thermostat,157,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp -RC200/CW100,thermostat,157,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio -RC200/CW100,thermostat,157,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor -RC200/CW100,thermostat,157,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor -RC200/CW100,thermostat,157,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler -RC200/CW100,thermostat,157,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler -RC200/CW100,thermostat,157,pvenableww,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenableww -RC200/CW100,thermostat,157,pvraiseheat,raise heating with PV,int (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat -RC200/CW100,thermostat,157,pvlowercool,lower cooling with PV,int (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool -RC200/CW100,thermostat,157,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -RC200/CW100,thermostat,157,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +RC200/CW100,thermostat,157,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp +RC200/CW100,thermostat,157,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio +RC200/CW100,thermostat,157,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor +RC200/CW100,thermostat,157,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor +RC200/CW100,thermostat,157,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler +RC200/CW100,thermostat,157,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler +RC200/CW100,thermostat,157,pvenabledhw,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenabledhw +RC200/CW100,thermostat,157,pvraiseheat,raise heating with PV,int8 (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat +RC200/CW100,thermostat,157,pvlowercool,lower cooling with PV,int8 (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool +RC200/CW100,thermostat,157,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +RC200/CW100,thermostat,157,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp RC200/CW100,thermostat,157,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate RC200/CW100,thermostat,157,mode,mode,enum [manual\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode RC200/CW100,thermostat,157,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype -RC200/CW100,thermostat,157,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp -RC200/CW100,thermostat,157,manualtemp,manual temperature,uint (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp -RC200/CW100,thermostat,157,comforttemp,comfort temperature,uint (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp -RC200/CW100,thermostat,157,summertemp,summer temperature,uint (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp -RC200/CW100,thermostat,157,designtemp,design temperature,uint (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp -RC200/CW100,thermostat,157,offsettemp,offset temperature,int (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp -RC200/CW100,thermostat,157,minflowtemp,min flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp -RC200/CW100,thermostat,157,maxflowtemp,max flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp -RC200/CW100,thermostat,157,roominfluence,room influence,uint (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence -RC200/CW100,thermostat,157,roominflfactor,room influence factor,uint (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor -RC200/CW100,thermostat,157,curroominfl,current room influence,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl +RC200/CW100,thermostat,157,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp +RC200/CW100,thermostat,157,manualtemp,manual temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp +RC200/CW100,thermostat,157,comforttemp,comfort temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp +RC200/CW100,thermostat,157,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp +RC200/CW100,thermostat,157,designtemp,design temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp +RC200/CW100,thermostat,157,offsettemp,offset temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp +RC200/CW100,thermostat,157,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp +RC200/CW100,thermostat,157,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp +RC200/CW100,thermostat,157,roominfluence,room influence,uint8 (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence +RC200/CW100,thermostat,157,roominflfactor,room influence factor,uint8 (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor +RC200/CW100,thermostat,157,curroominfl,current room influence,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl RC200/CW100,thermostat,157,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode -RC200/CW100,thermostat,157,nofrosttemp,nofrost temperature,int (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp -RC200/CW100,thermostat,157,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp +RC200/CW100,thermostat,157,nofrosttemp,nofrost temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp +RC200/CW100,thermostat,157,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp RC200/CW100,thermostat,157,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype RC200/CW100,thermostat,157,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode RC200/CW100,thermostat,157,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode @@ -3632,89 +3756,79 @@ RC200/CW100,thermostat,157,summermode,summer mode,enum [winter\|summer], ,false, RC200/CW100,thermostat,157,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate RC200/CW100,thermostat,157,controlmode,control mode,enum [optimized\|simple\|n/a\|room\|power], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode RC200/CW100,thermostat,157,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program -RC200/CW100,thermostat,157,tempautotemp,temporary set temperature automode,int (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp -RC200/CW100,thermostat,157,remoteseltemp,temporary set temperature from remote,int (>=-63<=63),C,false,sensor.thermostat_hc1_temporary_set_temperature_from_remote,sensor.thermostat_hc1_remoteseltemp -RC200/CW100,thermostat,157,fastheatup,fast heatup,uint (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup +RC200/CW100,thermostat,157,tempautotemp,temporary set temperature automode,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp +RC200/CW100,thermostat,157,remoteseltemp,temporary set temperature from remote,int8 (>=-63<=63),C,false,sensor.thermostat_hc1_temporary_set_temperature_from_remote,sensor.thermostat_hc1_remoteseltemp +RC200/CW100,thermostat,157,fastheatup,fast heatup,uint8 (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup RC200/CW100,thermostat,157,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization RC200/CW100,thermostat,157,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode -RC200/CW100,thermostat,157,noreducetemp,no reduce below temperature,int (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp -RC200/CW100,thermostat,157,reducetemp,off/reduce switch temperature,int (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp -RC200/CW100,thermostat,157,wwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_wwprio +RC200/CW100,thermostat,157,noreducetemp,no reduce below temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp +RC200/CW100,thermostat,157,reducetemp,off/reduce switch temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp +RC200/CW100,thermostat,157,dhwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_dhwprio RC200/CW100,thermostat,157,cooling,cooling,boolean, ,true,switch.thermostat_hc1_cooling,switch.thermostat_hc1_cooling RC200/CW100,thermostat,157,coolingon,cooling,boolean, ,false,binary_sensor.thermostat_hc1_cooling,binary_sensor.thermostat_hc1_coolingon RC200/CW100,thermostat,157,hpmode,HP Mode,enum [heating\|cooling\|heating&cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode -RC200/CW100,thermostat,157,dewoffset,dew point offset,uint (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset -RC200/CW100,thermostat,157,roomtempdiff,room temp difference,uint (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff -RC200/CW100,thermostat,157,hpminflowtemp,HP min. flow temp.,uint (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp +RC200/CW100,thermostat,157,dewoffset,dew point offset,uint8 (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset +RC200/CW100,thermostat,157,roomtempdiff,room temp difference,uint8 (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff +RC200/CW100,thermostat,157,hpminflowtemp,HP min. flow temp.,uint8 (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp RC200/CW100,thermostat,157,control,control device,enum [RC310\|RC200\|RC100\|RC100H\|TC100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control -RC200/CW100,thermostat,157,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp -RC200/CW100,thermostat,157,remotehum,room humidity from remote,uint (>=-1<=101),%,true,number.thermostat_hc1_room_humidity_from_remote,number.thermostat_hc1_remotehum -RC200/CW100,thermostat,157,heatondelay,heat-on delay,uint (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay -RC200/CW100,thermostat,157,heatoffdelay,heat-off delay,uint (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay -RC200/CW100,thermostat,157,instantstart,instant start,uint (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart +RC200/CW100,thermostat,157,remotetemp,room temperature from remote,int16 (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp +RC200/CW100,thermostat,157,remotehum,room humidity from remote,uint8 (>=-1<=101),%,true,number.thermostat_hc1_room_humidity_from_remote,number.thermostat_hc1_remotehum +RC200/CW100,thermostat,157,heatondelay,heat-on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay +RC200/CW100,thermostat,157,heatoffdelay,heat-off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay +RC200/CW100,thermostat,157,instantstart,instant start,uint8 (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart RC200/CW100,thermostat,157,boost,boost mode,boolean, ,true,switch.thermostat_hc1_boost_mode,switch.thermostat_hc1_boost -RC200/CW100,thermostat,157,boosttime,boost time,uint (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime +RC200/CW100,thermostat,157,boosttime,boost time,uint8 (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime +RC200/CW100,thermostat,157,mode,mode,enum [off\|normal\|comfort\|auto\|own prog], ,true,select.thermostat_dhw_mode,select.thermostat_dhw_mode +RC200/CW100,thermostat,157,settemp,set temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_temperature,number.thermostat_dhw_settemp +RC200/CW100,thermostat,157,settemplow,set low temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_low_temperature,number.thermostat_dhw_settemplow +RC200/CW100,thermostat,157,circmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_dhw_circulation_pump_mode,select.thermostat_dhw_circmode +RC200/CW100,thermostat,157,chargeduration,charge duration,uint8 (>=0<=3810),minutes,true,number.thermostat_dhw_charge_duration,number.thermostat_dhw_chargeduration +RC200/CW100,thermostat,157,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge +RC200/CW100,thermostat,157,extra,extra,uint8 (>=0<=254),C,false,sensor.thermostat_dhw_extra,sensor.thermostat_dhw_extra +RC200/CW100,thermostat,157,disinfecting,disinfecting,boolean, ,true,switch.thermostat_dhw_disinfecting,switch.thermostat_dhw_disinfecting +RC200/CW100,thermostat,157,disinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_dhw_disinfection_day,select.thermostat_dhw_disinfectday +RC200/CW100,thermostat,157,disinfecttime,disinfection time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_disinfection_time,number.thermostat_dhw_disinfecttime +RC200/CW100,thermostat,157,dailyheating,daily heating,boolean, ,true,switch.thermostat_dhw_daily_heating,switch.thermostat_dhw_dailyheating +RC200/CW100,thermostat,157,dailyheattime,daily heating time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_daily_heating_time,number.thermostat_dhw_dailyheattime RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,intoffset,internal temperature offset,int (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,intoffset,internal temperature offset,int8 (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,dampedoutdoortemp,damped outdoor temperature,short (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,floordrytemp,floor drying temperature,uint (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,dampedoutdoortemp,damped outdoor temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,floordrytemp,floor drying temperature,uint8 (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,minexttemp,minimal external temperature,int (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwsettemp,set temperature,uint (>=0<=254),C,true,number.thermostat_set_temperature,number.thermostat_wwsettemp -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwmode,mode,enum [off\|normal\|comfort\|auto\|own prog], ,true,select.thermostat_mode,select.thermostat_wwmode -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwmode,mode,enum [off\|normal\|comfort\|auto\|own prog], ,true,select.thermostat_wwc2_mode,select.thermostat_wwc2_wwmode -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwsettemplow,set low temperature,uint (>=0<=254),C,true,number.thermostat_set_low_temperature,number.thermostat_wwsettemplow -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwcircmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_circulation_pump_mode,select.thermostat_wwcircmode -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwchargeduration,charge duration,uint (>=0<=3810),minutes,true,number.thermostat_charge_duration,number.thermostat_wwchargeduration -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwextra1,circuit 1 extra,uint (>=0<=254),C,false,sensor.thermostat_circuit_1_extra,sensor.thermostat_wwextra1 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_disinfecting,switch.thermostat_wwdisinfecting -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_disinfection_day,select.thermostat_wwdisinfectday -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwdisinfecttime,disinfection time,uint (>=0<=1431),minutes,true,number.thermostat_disinfection_time,number.thermostat_wwdisinfecttime -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwdailyheating,daily heating,boolean, ,true,switch.thermostat_daily_heating,switch.thermostat_wwdailyheating -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwdailyheattime,daily heating time,uint (>=0<=1431),minutes,true,number.thermostat_daily_heating_time,number.thermostat_wwdailyheattime -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwcircmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_wwc2_circulation_pump_mode,select.thermostat_wwc2_wwcircmode -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwchargeduration,charge duration,uint (>=0<=3810),minutes,true,number.thermostat_wwc2_charge_duration,number.thermostat_wwc2_wwchargeduration -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwcharge,charge,boolean, ,true,switch.thermostat_wwc2_charge,switch.thermostat_wwc2_wwcharge -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwextra2,circuit 2 extra,uint (>=0<=254),C,false,sensor.thermostat_wwc2_circuit_2_extra,sensor.thermostat_wwc2_wwextra2 -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_wwc2_disinfecting,switch.thermostat_wwc2_wwdisinfecting -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_wwc2_disinfection_day,select.thermostat_wwc2_wwdisinfectday -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwdisinfecttime,disinfection time,uint (>=0<=1431),minutes,true,number.thermostat_wwc2_disinfection_time,number.thermostat_wwc2_wwdisinfecttime -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwdailyheating,daily heating,boolean, ,true,switch.thermostat_wwc2_daily_heating,switch.thermostat_wwc2_wwdailyheating -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwdailyheattime,daily heating time,uint (>=0<=1431),minutes,true,number.thermostat_wwc2_daily_heating_time,number.thermostat_wwc2_wwdailyheattime RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,pvenableww,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenableww -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,pvraiseheat,raise heating with PV,int (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,pvlowercool,lower cooling with PV,int (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,pvenabledhw,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenabledhw +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,pvraiseheat,raise heating with PV,int8 (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,pvlowercool,lower cooling with PV,int8 (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,mode,mode,enum [manual\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,manualtemp,manual temperature,uint (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,comforttemp,comfort temperature,uint (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,summertemp,summer temperature,uint (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,designtemp,design temperature,uint (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,offsettemp,offset temperature,int (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,minflowtemp,min flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,maxflowtemp,max flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,roominfluence,room influence,uint (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,roominflfactor,room influence factor,uint (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,curroominfl,current room influence,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,manualtemp,manual temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,comforttemp,comfort temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,designtemp,design temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,offsettemp,offset temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,roominfluence,room influence,uint8 (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,roominflfactor,room influence factor,uint8 (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,curroominfl,current room influence,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,nofrosttemp,nofrost temperature,int (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,nofrosttemp,nofrost temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode @@ -3722,89 +3836,79 @@ RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,summermode, RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,controlmode,control mode,enum [weather compensated\|outside basepoint\|n/a\|room\|power\|constant], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,tempautotemp,temporary set temperature automode,int (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,remoteseltemp,temporary set temperature from remote,int (>=-63<=63),C,false,sensor.thermostat_hc1_temporary_set_temperature_from_remote,sensor.thermostat_hc1_remoteseltemp -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,fastheatup,fast heatup,uint (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,tempautotemp,temporary set temperature automode,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,remoteseltemp,temporary set temperature from remote,int8 (>=-63<=63),C,false,sensor.thermostat_hc1_temporary_set_temperature_from_remote,sensor.thermostat_hc1_remoteseltemp +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,fastheatup,fast heatup,uint8 (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,noreducetemp,no reduce below temperature,int (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,reducetemp,off/reduce switch temperature,int (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_wwprio +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,noreducetemp,no reduce below temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,reducetemp,off/reduce switch temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,dhwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_dhwprio RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,cooling,cooling,boolean, ,true,switch.thermostat_hc1_cooling,switch.thermostat_hc1_cooling RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,coolingon,cooling,boolean, ,false,binary_sensor.thermostat_hc1_cooling,binary_sensor.thermostat_hc1_coolingon RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,hpmode,HP Mode,enum [heating\|cooling\|heating&cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,dewoffset,dew point offset,uint (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,roomtempdiff,room temp difference,uint (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,hpminflowtemp,HP min. flow temp.,uint (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,dewoffset,dew point offset,uint8 (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,roomtempdiff,room temp difference,uint8 (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,hpminflowtemp,HP min. flow temp.,uint8 (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,control,control device,enum [RC310\|RC200\|RC100\|RC100H\|TC100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,remotehum,room humidity from remote,uint (>=-1<=101),%,true,number.thermostat_hc1_room_humidity_from_remote,number.thermostat_hc1_remotehum -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,heatondelay,heat-on delay,uint (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,heatoffdelay,heat-off delay,uint (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,instantstart,instant start,uint (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,remotetemp,room temperature from remote,int16 (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,remotehum,room humidity from remote,uint8 (>=-1<=101),%,true,number.thermostat_hc1_room_humidity_from_remote,number.thermostat_hc1_remotehum +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,heatondelay,heat-on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,heatoffdelay,heat-off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,instantstart,instant start,uint8 (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,boost,boost mode,boolean, ,true,switch.thermostat_hc1_boost_mode,switch.thermostat_hc1_boost -RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,boosttime,boost time,uint (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,boosttime,boost time,uint8 (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,mode,mode,enum [off\|normal\|comfort\|auto\|own prog], ,true,select.thermostat_dhw_mode,select.thermostat_dhw_mode +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,settemp,set temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_temperature,number.thermostat_dhw_settemp +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,settemplow,set low temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_low_temperature,number.thermostat_dhw_settemplow +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,circmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_dhw_circulation_pump_mode,select.thermostat_dhw_circmode +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,chargeduration,charge duration,uint8 (>=0<=3810),minutes,true,number.thermostat_dhw_charge_duration,number.thermostat_dhw_chargeduration +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,extra,extra,uint8 (>=0<=254),C,false,sensor.thermostat_dhw_extra,sensor.thermostat_dhw_extra +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,disinfecting,disinfecting,boolean, ,true,switch.thermostat_dhw_disinfecting,switch.thermostat_dhw_disinfecting +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,disinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_dhw_disinfection_day,select.thermostat_dhw_disinfectday +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,disinfecttime,disinfection time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_disinfection_time,number.thermostat_dhw_disinfecttime +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,dailyheating,daily heating,boolean, ,true,switch.thermostat_dhw_daily_heating,switch.thermostat_dhw_dailyheating +RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,dailyheattime,daily heating time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_daily_heating_time,number.thermostat_dhw_dailyheattime RC100/Moduline 1000/1010,thermostat,165,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode RC100/Moduline 1000/1010,thermostat,165,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode RC100/Moduline 1000/1010,thermostat,165,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime -RC100/Moduline 1000/1010,thermostat,165,intoffset,internal temperature offset,int (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset +RC100/Moduline 1000/1010,thermostat,165,intoffset,internal temperature offset,int8 (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset RC100/Moduline 1000/1010,thermostat,165,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry -RC100/Moduline 1000/1010,thermostat,165,dampedoutdoortemp,damped outdoor temperature,short (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp -RC100/Moduline 1000/1010,thermostat,165,floordrytemp,floor drying temperature,uint (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp +RC100/Moduline 1000/1010,thermostat,165,dampedoutdoortemp,damped outdoor temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp +RC100/Moduline 1000/1010,thermostat,165,floordrytemp,floor drying temperature,uint8 (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp RC100/Moduline 1000/1010,thermostat,165,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building -RC100/Moduline 1000/1010,thermostat,165,minexttemp,minimal external temperature,int (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp +RC100/Moduline 1000/1010,thermostat,165,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp RC100/Moduline 1000/1010,thermostat,165,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping -RC100/Moduline 1000/1010,thermostat,165,wwsettemp,set temperature,uint (>=0<=254),C,true,number.thermostat_set_temperature,number.thermostat_wwsettemp -RC100/Moduline 1000/1010,thermostat,165,wwmode,mode,enum [off\|normal\|comfort\|auto\|own prog], ,true,select.thermostat_mode,select.thermostat_wwmode -RC100/Moduline 1000/1010,thermostat,165,wwmode,mode,enum [off\|normal\|comfort\|auto\|own prog], ,true,select.thermostat_wwc2_mode,select.thermostat_wwc2_wwmode -RC100/Moduline 1000/1010,thermostat,165,wwsettemplow,set low temperature,uint (>=0<=254),C,true,number.thermostat_set_low_temperature,number.thermostat_wwsettemplow -RC100/Moduline 1000/1010,thermostat,165,wwcircmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_circulation_pump_mode,select.thermostat_wwcircmode -RC100/Moduline 1000/1010,thermostat,165,wwchargeduration,charge duration,uint (>=0<=3810),minutes,true,number.thermostat_charge_duration,number.thermostat_wwchargeduration -RC100/Moduline 1000/1010,thermostat,165,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge -RC100/Moduline 1000/1010,thermostat,165,wwextra1,circuit 1 extra,uint (>=0<=254),C,false,sensor.thermostat_circuit_1_extra,sensor.thermostat_wwextra1 -RC100/Moduline 1000/1010,thermostat,165,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_disinfecting,switch.thermostat_wwdisinfecting -RC100/Moduline 1000/1010,thermostat,165,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_disinfection_day,select.thermostat_wwdisinfectday -RC100/Moduline 1000/1010,thermostat,165,wwdisinfecttime,disinfection time,uint (>=0<=1431),minutes,true,number.thermostat_disinfection_time,number.thermostat_wwdisinfecttime -RC100/Moduline 1000/1010,thermostat,165,wwdailyheating,daily heating,boolean, ,true,switch.thermostat_daily_heating,switch.thermostat_wwdailyheating -RC100/Moduline 1000/1010,thermostat,165,wwdailyheattime,daily heating time,uint (>=0<=1431),minutes,true,number.thermostat_daily_heating_time,number.thermostat_wwdailyheattime -RC100/Moduline 1000/1010,thermostat,165,wwcircmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_wwc2_circulation_pump_mode,select.thermostat_wwc2_wwcircmode -RC100/Moduline 1000/1010,thermostat,165,wwchargeduration,charge duration,uint (>=0<=3810),minutes,true,number.thermostat_wwc2_charge_duration,number.thermostat_wwc2_wwchargeduration -RC100/Moduline 1000/1010,thermostat,165,wwcharge,charge,boolean, ,true,switch.thermostat_wwc2_charge,switch.thermostat_wwc2_wwcharge -RC100/Moduline 1000/1010,thermostat,165,wwextra2,circuit 2 extra,uint (>=0<=254),C,false,sensor.thermostat_wwc2_circuit_2_extra,sensor.thermostat_wwc2_wwextra2 -RC100/Moduline 1000/1010,thermostat,165,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_wwc2_disinfecting,switch.thermostat_wwc2_wwdisinfecting -RC100/Moduline 1000/1010,thermostat,165,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_wwc2_disinfection_day,select.thermostat_wwc2_wwdisinfectday -RC100/Moduline 1000/1010,thermostat,165,wwdisinfecttime,disinfection time,uint (>=0<=1431),minutes,true,number.thermostat_wwc2_disinfection_time,number.thermostat_wwc2_wwdisinfecttime -RC100/Moduline 1000/1010,thermostat,165,wwdailyheating,daily heating,boolean, ,true,switch.thermostat_wwc2_daily_heating,switch.thermostat_wwc2_wwdailyheating -RC100/Moduline 1000/1010,thermostat,165,wwdailyheattime,daily heating time,uint (>=0<=1431),minutes,true,number.thermostat_wwc2_daily_heating_time,number.thermostat_wwc2_wwdailyheattime RC100/Moduline 1000/1010,thermostat,165,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy -RC100/Moduline 1000/1010,thermostat,165,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp -RC100/Moduline 1000/1010,thermostat,165,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio -RC100/Moduline 1000/1010,thermostat,165,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor -RC100/Moduline 1000/1010,thermostat,165,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor -RC100/Moduline 1000/1010,thermostat,165,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler -RC100/Moduline 1000/1010,thermostat,165,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler -RC100/Moduline 1000/1010,thermostat,165,pvenableww,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenableww -RC100/Moduline 1000/1010,thermostat,165,pvraiseheat,raise heating with PV,int (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat -RC100/Moduline 1000/1010,thermostat,165,pvlowercool,lower cooling with PV,int (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool -RC100/Moduline 1000/1010,thermostat,165,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -RC100/Moduline 1000/1010,thermostat,165,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +RC100/Moduline 1000/1010,thermostat,165,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp +RC100/Moduline 1000/1010,thermostat,165,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio +RC100/Moduline 1000/1010,thermostat,165,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor +RC100/Moduline 1000/1010,thermostat,165,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor +RC100/Moduline 1000/1010,thermostat,165,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler +RC100/Moduline 1000/1010,thermostat,165,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler +RC100/Moduline 1000/1010,thermostat,165,pvenabledhw,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenabledhw +RC100/Moduline 1000/1010,thermostat,165,pvraiseheat,raise heating with PV,int8 (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat +RC100/Moduline 1000/1010,thermostat,165,pvlowercool,lower cooling with PV,int8 (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool +RC100/Moduline 1000/1010,thermostat,165,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +RC100/Moduline 1000/1010,thermostat,165,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp RC100/Moduline 1000/1010,thermostat,165,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate RC100/Moduline 1000/1010,thermostat,165,mode,mode,enum [manual\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode RC100/Moduline 1000/1010,thermostat,165,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype -RC100/Moduline 1000/1010,thermostat,165,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp -RC100/Moduline 1000/1010,thermostat,165,manualtemp,manual temperature,uint (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp -RC100/Moduline 1000/1010,thermostat,165,comforttemp,comfort temperature,uint (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp -RC100/Moduline 1000/1010,thermostat,165,summertemp,summer temperature,uint (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp -RC100/Moduline 1000/1010,thermostat,165,designtemp,design temperature,uint (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp -RC100/Moduline 1000/1010,thermostat,165,offsettemp,offset temperature,int (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp -RC100/Moduline 1000/1010,thermostat,165,minflowtemp,min flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp -RC100/Moduline 1000/1010,thermostat,165,maxflowtemp,max flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp -RC100/Moduline 1000/1010,thermostat,165,roominfluence,room influence,uint (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence -RC100/Moduline 1000/1010,thermostat,165,roominflfactor,room influence factor,uint (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor -RC100/Moduline 1000/1010,thermostat,165,curroominfl,current room influence,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl +RC100/Moduline 1000/1010,thermostat,165,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp +RC100/Moduline 1000/1010,thermostat,165,manualtemp,manual temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp +RC100/Moduline 1000/1010,thermostat,165,comforttemp,comfort temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp +RC100/Moduline 1000/1010,thermostat,165,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp +RC100/Moduline 1000/1010,thermostat,165,designtemp,design temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp +RC100/Moduline 1000/1010,thermostat,165,offsettemp,offset temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp +RC100/Moduline 1000/1010,thermostat,165,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp +RC100/Moduline 1000/1010,thermostat,165,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp +RC100/Moduline 1000/1010,thermostat,165,roominfluence,room influence,uint8 (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence +RC100/Moduline 1000/1010,thermostat,165,roominflfactor,room influence factor,uint8 (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor +RC100/Moduline 1000/1010,thermostat,165,curroominfl,current room influence,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl RC100/Moduline 1000/1010,thermostat,165,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode -RC100/Moduline 1000/1010,thermostat,165,nofrosttemp,nofrost temperature,int (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp -RC100/Moduline 1000/1010,thermostat,165,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp +RC100/Moduline 1000/1010,thermostat,165,nofrosttemp,nofrost temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp +RC100/Moduline 1000/1010,thermostat,165,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp RC100/Moduline 1000/1010,thermostat,165,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype RC100/Moduline 1000/1010,thermostat,165,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode RC100/Moduline 1000/1010,thermostat,165,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode @@ -3812,89 +3916,79 @@ RC100/Moduline 1000/1010,thermostat,165,summermode,summer mode,enum [winter\|sum RC100/Moduline 1000/1010,thermostat,165,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate RC100/Moduline 1000/1010,thermostat,165,controlmode,control mode,enum [optimized\|simple\|n/a\|room\|power], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode RC100/Moduline 1000/1010,thermostat,165,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program -RC100/Moduline 1000/1010,thermostat,165,tempautotemp,temporary set temperature automode,int (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp -RC100/Moduline 1000/1010,thermostat,165,remoteseltemp,temporary set temperature from remote,int (>=-63<=63),C,false,sensor.thermostat_hc1_temporary_set_temperature_from_remote,sensor.thermostat_hc1_remoteseltemp -RC100/Moduline 1000/1010,thermostat,165,fastheatup,fast heatup,uint (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup +RC100/Moduline 1000/1010,thermostat,165,tempautotemp,temporary set temperature automode,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp +RC100/Moduline 1000/1010,thermostat,165,remoteseltemp,temporary set temperature from remote,int8 (>=-63<=63),C,false,sensor.thermostat_hc1_temporary_set_temperature_from_remote,sensor.thermostat_hc1_remoteseltemp +RC100/Moduline 1000/1010,thermostat,165,fastheatup,fast heatup,uint8 (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup RC100/Moduline 1000/1010,thermostat,165,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization RC100/Moduline 1000/1010,thermostat,165,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode -RC100/Moduline 1000/1010,thermostat,165,noreducetemp,no reduce below temperature,int (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp -RC100/Moduline 1000/1010,thermostat,165,reducetemp,off/reduce switch temperature,int (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp -RC100/Moduline 1000/1010,thermostat,165,wwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_wwprio +RC100/Moduline 1000/1010,thermostat,165,noreducetemp,no reduce below temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp +RC100/Moduline 1000/1010,thermostat,165,reducetemp,off/reduce switch temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp +RC100/Moduline 1000/1010,thermostat,165,dhwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_dhwprio RC100/Moduline 1000/1010,thermostat,165,cooling,cooling,boolean, ,true,switch.thermostat_hc1_cooling,switch.thermostat_hc1_cooling RC100/Moduline 1000/1010,thermostat,165,coolingon,cooling,boolean, ,false,binary_sensor.thermostat_hc1_cooling,binary_sensor.thermostat_hc1_coolingon RC100/Moduline 1000/1010,thermostat,165,hpmode,HP Mode,enum [heating\|cooling\|heating&cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode -RC100/Moduline 1000/1010,thermostat,165,dewoffset,dew point offset,uint (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset -RC100/Moduline 1000/1010,thermostat,165,roomtempdiff,room temp difference,uint (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff -RC100/Moduline 1000/1010,thermostat,165,hpminflowtemp,HP min. flow temp.,uint (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp +RC100/Moduline 1000/1010,thermostat,165,dewoffset,dew point offset,uint8 (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset +RC100/Moduline 1000/1010,thermostat,165,roomtempdiff,room temp difference,uint8 (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff +RC100/Moduline 1000/1010,thermostat,165,hpminflowtemp,HP min. flow temp.,uint8 (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp RC100/Moduline 1000/1010,thermostat,165,control,control device,enum [RC310\|RC200\|RC100\|RC100H\|TC100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control -RC100/Moduline 1000/1010,thermostat,165,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp -RC100/Moduline 1000/1010,thermostat,165,remotehum,room humidity from remote,uint (>=-1<=101),%,true,number.thermostat_hc1_room_humidity_from_remote,number.thermostat_hc1_remotehum -RC100/Moduline 1000/1010,thermostat,165,heatondelay,heat-on delay,uint (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay -RC100/Moduline 1000/1010,thermostat,165,heatoffdelay,heat-off delay,uint (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay -RC100/Moduline 1000/1010,thermostat,165,instantstart,instant start,uint (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart +RC100/Moduline 1000/1010,thermostat,165,remotetemp,room temperature from remote,int16 (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp +RC100/Moduline 1000/1010,thermostat,165,remotehum,room humidity from remote,uint8 (>=-1<=101),%,true,number.thermostat_hc1_room_humidity_from_remote,number.thermostat_hc1_remotehum +RC100/Moduline 1000/1010,thermostat,165,heatondelay,heat-on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay +RC100/Moduline 1000/1010,thermostat,165,heatoffdelay,heat-off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay +RC100/Moduline 1000/1010,thermostat,165,instantstart,instant start,uint8 (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart RC100/Moduline 1000/1010,thermostat,165,boost,boost mode,boolean, ,true,switch.thermostat_hc1_boost_mode,switch.thermostat_hc1_boost -RC100/Moduline 1000/1010,thermostat,165,boosttime,boost time,uint (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime +RC100/Moduline 1000/1010,thermostat,165,boosttime,boost time,uint8 (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime +RC100/Moduline 1000/1010,thermostat,165,mode,mode,enum [off\|normal\|comfort\|auto\|own prog], ,true,select.thermostat_dhw_mode,select.thermostat_dhw_mode +RC100/Moduline 1000/1010,thermostat,165,settemp,set temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_temperature,number.thermostat_dhw_settemp +RC100/Moduline 1000/1010,thermostat,165,settemplow,set low temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_low_temperature,number.thermostat_dhw_settemplow +RC100/Moduline 1000/1010,thermostat,165,circmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_dhw_circulation_pump_mode,select.thermostat_dhw_circmode +RC100/Moduline 1000/1010,thermostat,165,chargeduration,charge duration,uint8 (>=0<=3810),minutes,true,number.thermostat_dhw_charge_duration,number.thermostat_dhw_chargeduration +RC100/Moduline 1000/1010,thermostat,165,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge +RC100/Moduline 1000/1010,thermostat,165,extra,extra,uint8 (>=0<=254),C,false,sensor.thermostat_dhw_extra,sensor.thermostat_dhw_extra +RC100/Moduline 1000/1010,thermostat,165,disinfecting,disinfecting,boolean, ,true,switch.thermostat_dhw_disinfecting,switch.thermostat_dhw_disinfecting +RC100/Moduline 1000/1010,thermostat,165,disinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_dhw_disinfection_day,select.thermostat_dhw_disinfectday +RC100/Moduline 1000/1010,thermostat,165,disinfecttime,disinfection time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_disinfection_time,number.thermostat_dhw_disinfecttime +RC100/Moduline 1000/1010,thermostat,165,dailyheating,daily heating,boolean, ,true,switch.thermostat_dhw_daily_heating,switch.thermostat_dhw_dailyheating +RC100/Moduline 1000/1010,thermostat,165,dailyheattime,daily heating time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_daily_heating_time,number.thermostat_dhw_dailyheattime Rego 2000/3000,thermostat,172,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode Rego 2000/3000,thermostat,172,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode Rego 2000/3000,thermostat,172,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime -Rego 2000/3000,thermostat,172,intoffset,internal temperature offset,int (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset +Rego 2000/3000,thermostat,172,intoffset,internal temperature offset,int8 (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset Rego 2000/3000,thermostat,172,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry -Rego 2000/3000,thermostat,172,dampedoutdoortemp,damped outdoor temperature,short (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp -Rego 2000/3000,thermostat,172,floordrytemp,floor drying temperature,uint (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp +Rego 2000/3000,thermostat,172,dampedoutdoortemp,damped outdoor temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp +Rego 2000/3000,thermostat,172,floordrytemp,floor drying temperature,uint8 (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp Rego 2000/3000,thermostat,172,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building -Rego 2000/3000,thermostat,172,minexttemp,minimal external temperature,int (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp +Rego 2000/3000,thermostat,172,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp Rego 2000/3000,thermostat,172,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping -Rego 2000/3000,thermostat,172,wwsettemp,set temperature,uint (>=0<=254),C,true,number.thermostat_set_temperature,number.thermostat_wwsettemp -Rego 2000/3000,thermostat,172,wwmode,mode,enum [off\|normal\|comfort\|auto\|own prog], ,true,select.thermostat_mode,select.thermostat_wwmode -Rego 2000/3000,thermostat,172,wwmode,mode,enum [off\|normal\|comfort\|auto\|own prog], ,true,select.thermostat_wwc2_mode,select.thermostat_wwc2_wwmode -Rego 2000/3000,thermostat,172,wwsettemplow,set low temperature,uint (>=0<=254),C,true,number.thermostat_set_low_temperature,number.thermostat_wwsettemplow -Rego 2000/3000,thermostat,172,wwcircmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_circulation_pump_mode,select.thermostat_wwcircmode -Rego 2000/3000,thermostat,172,wwchargeduration,charge duration,uint (>=0<=3810),minutes,true,number.thermostat_charge_duration,number.thermostat_wwchargeduration -Rego 2000/3000,thermostat,172,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge -Rego 2000/3000,thermostat,172,wwextra1,circuit 1 extra,uint (>=0<=254),C,false,sensor.thermostat_circuit_1_extra,sensor.thermostat_wwextra1 -Rego 2000/3000,thermostat,172,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_disinfecting,switch.thermostat_wwdisinfecting -Rego 2000/3000,thermostat,172,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_disinfection_day,select.thermostat_wwdisinfectday -Rego 2000/3000,thermostat,172,wwdisinfecttime,disinfection time,uint (>=0<=1431),minutes,true,number.thermostat_disinfection_time,number.thermostat_wwdisinfecttime -Rego 2000/3000,thermostat,172,wwdailyheating,daily heating,boolean, ,true,switch.thermostat_daily_heating,switch.thermostat_wwdailyheating -Rego 2000/3000,thermostat,172,wwdailyheattime,daily heating time,uint (>=0<=1431),minutes,true,number.thermostat_daily_heating_time,number.thermostat_wwdailyheattime -Rego 2000/3000,thermostat,172,wwcircmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_wwc2_circulation_pump_mode,select.thermostat_wwc2_wwcircmode -Rego 2000/3000,thermostat,172,wwchargeduration,charge duration,uint (>=0<=3810),minutes,true,number.thermostat_wwc2_charge_duration,number.thermostat_wwc2_wwchargeduration -Rego 2000/3000,thermostat,172,wwcharge,charge,boolean, ,true,switch.thermostat_wwc2_charge,switch.thermostat_wwc2_wwcharge -Rego 2000/3000,thermostat,172,wwextra2,circuit 2 extra,uint (>=0<=254),C,false,sensor.thermostat_wwc2_circuit_2_extra,sensor.thermostat_wwc2_wwextra2 -Rego 2000/3000,thermostat,172,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_wwc2_disinfecting,switch.thermostat_wwc2_wwdisinfecting -Rego 2000/3000,thermostat,172,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_wwc2_disinfection_day,select.thermostat_wwc2_wwdisinfectday -Rego 2000/3000,thermostat,172,wwdisinfecttime,disinfection time,uint (>=0<=1431),minutes,true,number.thermostat_wwc2_disinfection_time,number.thermostat_wwc2_wwdisinfecttime -Rego 2000/3000,thermostat,172,wwdailyheating,daily heating,boolean, ,true,switch.thermostat_wwc2_daily_heating,switch.thermostat_wwc2_wwdailyheating -Rego 2000/3000,thermostat,172,wwdailyheattime,daily heating time,uint (>=0<=1431),minutes,true,number.thermostat_wwc2_daily_heating_time,number.thermostat_wwc2_wwdailyheattime Rego 2000/3000,thermostat,172,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy -Rego 2000/3000,thermostat,172,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp -Rego 2000/3000,thermostat,172,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio -Rego 2000/3000,thermostat,172,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor -Rego 2000/3000,thermostat,172,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor -Rego 2000/3000,thermostat,172,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler -Rego 2000/3000,thermostat,172,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler -Rego 2000/3000,thermostat,172,pvenableww,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenableww -Rego 2000/3000,thermostat,172,pvraiseheat,raise heating with PV,int (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat -Rego 2000/3000,thermostat,172,pvlowercool,lower cooling with PV,int (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool -Rego 2000/3000,thermostat,172,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -Rego 2000/3000,thermostat,172,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +Rego 2000/3000,thermostat,172,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp +Rego 2000/3000,thermostat,172,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio +Rego 2000/3000,thermostat,172,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor +Rego 2000/3000,thermostat,172,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor +Rego 2000/3000,thermostat,172,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler +Rego 2000/3000,thermostat,172,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler +Rego 2000/3000,thermostat,172,pvenabledhw,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenabledhw +Rego 2000/3000,thermostat,172,pvraiseheat,raise heating with PV,int8 (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat +Rego 2000/3000,thermostat,172,pvlowercool,lower cooling with PV,int8 (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool +Rego 2000/3000,thermostat,172,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +Rego 2000/3000,thermostat,172,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp Rego 2000/3000,thermostat,172,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate Rego 2000/3000,thermostat,172,mode,mode,enum [manual\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode Rego 2000/3000,thermostat,172,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype -Rego 2000/3000,thermostat,172,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp -Rego 2000/3000,thermostat,172,manualtemp,manual temperature,uint (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp -Rego 2000/3000,thermostat,172,comforttemp,comfort temperature,uint (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp -Rego 2000/3000,thermostat,172,summertemp,summer temperature,uint (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp -Rego 2000/3000,thermostat,172,designtemp,design temperature,uint (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp -Rego 2000/3000,thermostat,172,offsettemp,offset temperature,int (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp -Rego 2000/3000,thermostat,172,minflowtemp,min flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp -Rego 2000/3000,thermostat,172,maxflowtemp,max flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp -Rego 2000/3000,thermostat,172,roominfluence,room influence,uint (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence -Rego 2000/3000,thermostat,172,roominflfactor,room influence factor,uint (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor -Rego 2000/3000,thermostat,172,curroominfl,current room influence,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl +Rego 2000/3000,thermostat,172,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp +Rego 2000/3000,thermostat,172,manualtemp,manual temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp +Rego 2000/3000,thermostat,172,comforttemp,comfort temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp +Rego 2000/3000,thermostat,172,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp +Rego 2000/3000,thermostat,172,designtemp,design temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp +Rego 2000/3000,thermostat,172,offsettemp,offset temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp +Rego 2000/3000,thermostat,172,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp +Rego 2000/3000,thermostat,172,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp +Rego 2000/3000,thermostat,172,roominfluence,room influence,uint8 (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence +Rego 2000/3000,thermostat,172,roominflfactor,room influence factor,uint8 (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor +Rego 2000/3000,thermostat,172,curroominfl,current room influence,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl Rego 2000/3000,thermostat,172,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode -Rego 2000/3000,thermostat,172,nofrosttemp,nofrost temperature,int (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp -Rego 2000/3000,thermostat,172,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp +Rego 2000/3000,thermostat,172,nofrosttemp,nofrost temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp +Rego 2000/3000,thermostat,172,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp Rego 2000/3000,thermostat,172,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype Rego 2000/3000,thermostat,172,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode Rego 2000/3000,thermostat,172,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode @@ -3902,116 +3996,106 @@ Rego 2000/3000,thermostat,172,summermode,summer mode,enum [winter\|summer], ,fal Rego 2000/3000,thermostat,172,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate Rego 2000/3000,thermostat,172,controlmode,control mode,enum [weather compensated\|outside basepoint\|n/a\|room\|power\|constant], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode Rego 2000/3000,thermostat,172,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program -Rego 2000/3000,thermostat,172,tempautotemp,temporary set temperature automode,int (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp -Rego 2000/3000,thermostat,172,remoteseltemp,temporary set temperature from remote,int (>=-63<=63),C,false,sensor.thermostat_hc1_temporary_set_temperature_from_remote,sensor.thermostat_hc1_remoteseltemp -Rego 2000/3000,thermostat,172,fastheatup,fast heatup,uint (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup +Rego 2000/3000,thermostat,172,tempautotemp,temporary set temperature automode,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp +Rego 2000/3000,thermostat,172,remoteseltemp,temporary set temperature from remote,int8 (>=-63<=63),C,false,sensor.thermostat_hc1_temporary_set_temperature_from_remote,sensor.thermostat_hc1_remoteseltemp +Rego 2000/3000,thermostat,172,fastheatup,fast heatup,uint8 (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup Rego 2000/3000,thermostat,172,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization Rego 2000/3000,thermostat,172,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode -Rego 2000/3000,thermostat,172,noreducetemp,no reduce below temperature,int (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp -Rego 2000/3000,thermostat,172,reducetemp,off/reduce switch temperature,int (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp -Rego 2000/3000,thermostat,172,wwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_wwprio +Rego 2000/3000,thermostat,172,noreducetemp,no reduce below temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp +Rego 2000/3000,thermostat,172,reducetemp,off/reduce switch temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp +Rego 2000/3000,thermostat,172,dhwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_dhwprio Rego 2000/3000,thermostat,172,cooling,cooling,boolean, ,true,switch.thermostat_hc1_cooling,switch.thermostat_hc1_cooling Rego 2000/3000,thermostat,172,coolingon,cooling,boolean, ,false,binary_sensor.thermostat_hc1_cooling,binary_sensor.thermostat_hc1_coolingon Rego 2000/3000,thermostat,172,hpmode,HP Mode,enum [heating\|cooling\|heating&cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode -Rego 2000/3000,thermostat,172,dewoffset,dew point offset,uint (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset -Rego 2000/3000,thermostat,172,roomtempdiff,room temp difference,uint (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff -Rego 2000/3000,thermostat,172,hpminflowtemp,HP min. flow temp.,uint (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp +Rego 2000/3000,thermostat,172,dewoffset,dew point offset,uint8 (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset +Rego 2000/3000,thermostat,172,roomtempdiff,room temp difference,uint8 (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff +Rego 2000/3000,thermostat,172,hpminflowtemp,HP min. flow temp.,uint8 (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp Rego 2000/3000,thermostat,172,control,control device,enum [RC310\|RC200\|RC100\|RC100H\|TC100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control -Rego 2000/3000,thermostat,172,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp -Rego 2000/3000,thermostat,172,remotehum,room humidity from remote,uint (>=-1<=101),%,true,number.thermostat_hc1_room_humidity_from_remote,number.thermostat_hc1_remotehum -Rego 2000/3000,thermostat,172,heatondelay,heat-on delay,uint (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay -Rego 2000/3000,thermostat,172,heatoffdelay,heat-off delay,uint (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay -Rego 2000/3000,thermostat,172,instantstart,instant start,uint (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart +Rego 2000/3000,thermostat,172,remotetemp,room temperature from remote,int16 (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp +Rego 2000/3000,thermostat,172,remotehum,room humidity from remote,uint8 (>=-1<=101),%,true,number.thermostat_hc1_room_humidity_from_remote,number.thermostat_hc1_remotehum +Rego 2000/3000,thermostat,172,heatondelay,heat-on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay +Rego 2000/3000,thermostat,172,heatoffdelay,heat-off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay +Rego 2000/3000,thermostat,172,instantstart,instant start,uint8 (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart Rego 2000/3000,thermostat,172,boost,boost mode,boolean, ,true,switch.thermostat_hc1_boost_mode,switch.thermostat_hc1_boost -Rego 2000/3000,thermostat,172,boosttime,boost time,uint (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime +Rego 2000/3000,thermostat,172,boosttime,boost time,uint8 (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime +Rego 2000/3000,thermostat,172,mode,mode,enum [normal\|comfort\|eco+], ,true,select.thermostat_dhw_mode,select.thermostat_dhw_mode +Rego 2000/3000,thermostat,172,settemp,set temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_temperature,number.thermostat_dhw_settemp +Rego 2000/3000,thermostat,172,settemplow,set low temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_low_temperature,number.thermostat_dhw_settemplow +Rego 2000/3000,thermostat,172,circmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_dhw_circulation_pump_mode,select.thermostat_dhw_circmode +Rego 2000/3000,thermostat,172,chargeduration,charge duration,uint8 (>=0<=3810),minutes,true,number.thermostat_dhw_charge_duration,number.thermostat_dhw_chargeduration +Rego 2000/3000,thermostat,172,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge +Rego 2000/3000,thermostat,172,extra,extra,uint8 (>=0<=254),C,false,sensor.thermostat_dhw_extra,sensor.thermostat_dhw_extra +Rego 2000/3000,thermostat,172,disinfecting,disinfecting,boolean, ,true,switch.thermostat_dhw_disinfecting,switch.thermostat_dhw_disinfecting +Rego 2000/3000,thermostat,172,disinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_dhw_disinfection_day,select.thermostat_dhw_disinfectday +Rego 2000/3000,thermostat,172,disinfecttime,disinfection time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_disinfection_time,number.thermostat_dhw_disinfecttime +Rego 2000/3000,thermostat,172,dailyheating,daily heating,boolean, ,true,switch.thermostat_dhw_daily_heating,switch.thermostat_dhw_dailyheating +Rego 2000/3000,thermostat,172,dailyheattime,daily heating time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_daily_heating_time,number.thermostat_dhw_dailyheattime Comfort RF,thermostat,215,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode Comfort RF,thermostat,215,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode Comfort RF,thermostat,215,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime -Comfort RF,thermostat,215,seltemp,selected room temperature,short (>=-15999<=15999),C,false,sensor.thermostat_hc1_selected_room_temperature,sensor.thermostat_hc1_seltemp -Comfort RF,thermostat,215,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +Comfort RF,thermostat,215,seltemp,selected room temperature,int16 (>=-15999<=15999),C,false,sensor.thermostat_hc1_selected_room_temperature,sensor.thermostat_hc1_seltemp +Comfort RF,thermostat,215,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp Comfort RF,thermostat,215,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate Comfort RF,thermostat,215,mode,mode,enum [auto\|off], ,false,sensor.thermostat_hc1_mode,sensor.thermostat_hc1_mode Comfort RF,thermostat,215,modetype,mode type,enum [off\|on], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype -Comfort RF,thermostat,215,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp +Comfort RF,thermostat,215,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp CRF200S,thermostat,216,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode CRF200S,thermostat,216,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode CRF200S,thermostat,216,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime -CRF200S,thermostat,216,seltemp,selected room temperature,short (>=-15999<=15999),C,false,sensor.thermostat_hc1_selected_room_temperature,sensor.thermostat_hc1_seltemp -CRF200S,thermostat,216,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +CRF200S,thermostat,216,seltemp,selected room temperature,int16 (>=-15999<=15999),C,false,sensor.thermostat_hc1_selected_room_temperature,sensor.thermostat_hc1_seltemp +CRF200S,thermostat,216,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp CRF200S,thermostat,216,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate CRF200S,thermostat,216,mode,mode,enum [auto\|off], ,false,sensor.thermostat_hc1_mode,sensor.thermostat_hc1_mode CRF200S,thermostat,216,modetype,mode type,enum [off\|on], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype -CRF200S,thermostat,216,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp +CRF200S,thermostat,216,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp Comfort+2RF,thermostat,246,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode Comfort+2RF,thermostat,246,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode Comfort+2RF,thermostat,246,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime -Comfort+2RF,thermostat,246,seltemp,selected room temperature,short (>=-15999<=15999),C,false,sensor.thermostat_hc1_selected_room_temperature,sensor.thermostat_hc1_seltemp -Comfort+2RF,thermostat,246,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +Comfort+2RF,thermostat,246,seltemp,selected room temperature,int16 (>=-15999<=15999),C,false,sensor.thermostat_hc1_selected_room_temperature,sensor.thermostat_hc1_seltemp +Comfort+2RF,thermostat,246,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp Comfort+2RF,thermostat,246,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate Comfort+2RF,thermostat,246,mode,mode,enum [auto\|off], ,false,sensor.thermostat_hc1_mode,sensor.thermostat_hc1_mode Comfort+2RF,thermostat,246,modetype,mode type,enum [off\|on], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype -Comfort+2RF,thermostat,246,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp +Comfort+2RF,thermostat,246,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp Rego 3000/UI800/WSW196i/BC400,thermostat,253,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode Rego 3000/UI800/WSW196i/BC400,thermostat,253,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode Rego 3000/UI800/WSW196i/BC400,thermostat,253,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime -Rego 3000/UI800/WSW196i/BC400,thermostat,253,intoffset,internal temperature offset,int (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset +Rego 3000/UI800/WSW196i/BC400,thermostat,253,intoffset,internal temperature offset,int8 (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset Rego 3000/UI800/WSW196i/BC400,thermostat,253,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry -Rego 3000/UI800/WSW196i/BC400,thermostat,253,dampedoutdoortemp,damped outdoor temperature,short (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp -Rego 3000/UI800/WSW196i/BC400,thermostat,253,floordrytemp,floor drying temperature,uint (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,dampedoutdoortemp,damped outdoor temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,floordrytemp,floor drying temperature,uint8 (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp Rego 3000/UI800/WSW196i/BC400,thermostat,253,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building -Rego 3000/UI800/WSW196i/BC400,thermostat,253,minexttemp,minimal external temperature,int (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp Rego 3000/UI800/WSW196i/BC400,thermostat,253,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping -Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwsettemp,set temperature,uint (>=0<=254),C,true,number.thermostat_set_temperature,number.thermostat_wwsettemp -Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwmode,mode,enum [off\|eco+\|eco\|comfort\|auto], ,true,select.thermostat_mode,select.thermostat_wwmode -Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwmode,mode,enum [off\|eco+\|eco\|comfort\|auto], ,true,select.thermostat_wwc2_mode,select.thermostat_wwc2_wwmode -Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwsettemplow,set low temperature,uint (>=0<=254),C,true,number.thermostat_set_low_temperature,number.thermostat_wwsettemplow -Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwcircmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_circulation_pump_mode,select.thermostat_wwcircmode -Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwchargeduration,charge duration,uint (>=0<=3810),minutes,true,number.thermostat_charge_duration,number.thermostat_wwchargeduration -Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge -Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwextra1,circuit 1 extra,uint (>=0<=254),C,false,sensor.thermostat_circuit_1_extra,sensor.thermostat_wwextra1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_disinfecting,switch.thermostat_wwdisinfecting -Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_disinfection_day,select.thermostat_wwdisinfectday -Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwdisinfecttime,disinfection time,uint (>=0<=1431),minutes,true,number.thermostat_disinfection_time,number.thermostat_wwdisinfecttime -Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwdailyheating,daily heating,boolean, ,true,switch.thermostat_daily_heating,switch.thermostat_wwdailyheating -Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwdailyheattime,daily heating time,uint (>=0<=1431),minutes,true,number.thermostat_daily_heating_time,number.thermostat_wwdailyheattime -Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwcircmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_wwc2_circulation_pump_mode,select.thermostat_wwc2_wwcircmode -Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwchargeduration,charge duration,uint (>=0<=3810),minutes,true,number.thermostat_wwc2_charge_duration,number.thermostat_wwc2_wwchargeduration -Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwcharge,charge,boolean, ,true,switch.thermostat_wwc2_charge,switch.thermostat_wwc2_wwcharge -Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwextra2,circuit 2 extra,uint (>=0<=254),C,false,sensor.thermostat_wwc2_circuit_2_extra,sensor.thermostat_wwc2_wwextra2 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_wwc2_disinfecting,switch.thermostat_wwc2_wwdisinfecting -Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_wwc2_disinfection_day,select.thermostat_wwc2_wwdisinfectday -Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwdisinfecttime,disinfection time,uint (>=0<=1431),minutes,true,number.thermostat_wwc2_disinfection_time,number.thermostat_wwc2_wwdisinfecttime -Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwdailyheating,daily heating,boolean, ,true,switch.thermostat_wwc2_daily_heating,switch.thermostat_wwc2_wwdailyheating -Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwdailyheattime,daily heating time,uint (>=0<=1431),minutes,true,number.thermostat_wwc2_daily_heating_time,number.thermostat_wwc2_wwdailyheattime Rego 3000/UI800/WSW196i/BC400,thermostat,253,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy -Rego 3000/UI800/WSW196i/BC400,thermostat,253,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp -Rego 3000/UI800/WSW196i/BC400,thermostat,253,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio -Rego 3000/UI800/WSW196i/BC400,thermostat,253,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor -Rego 3000/UI800/WSW196i/BC400,thermostat,253,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor -Rego 3000/UI800/WSW196i/BC400,thermostat,253,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler -Rego 3000/UI800/WSW196i/BC400,thermostat,253,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler -Rego 3000/UI800/WSW196i/BC400,thermostat,253,pvenableww,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenableww -Rego 3000/UI800/WSW196i/BC400,thermostat,253,pvraiseheat,raise heating with PV,int (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat -Rego 3000/UI800/WSW196i/BC400,thermostat,253,pvlowercool,lower cooling with PV,int (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool -Rego 3000/UI800/WSW196i/BC400,thermostat,253,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -Rego 3000/UI800/WSW196i/BC400,thermostat,253,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio +Rego 3000/UI800/WSW196i/BC400,thermostat,253,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor +Rego 3000/UI800/WSW196i/BC400,thermostat,253,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor +Rego 3000/UI800/WSW196i/BC400,thermostat,253,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler +Rego 3000/UI800/WSW196i/BC400,thermostat,253,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler +Rego 3000/UI800/WSW196i/BC400,thermostat,253,pvenabledhw,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenabledhw +Rego 3000/UI800/WSW196i/BC400,thermostat,253,pvraiseheat,raise heating with PV,int8 (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat +Rego 3000/UI800/WSW196i/BC400,thermostat,253,pvlowercool,lower cooling with PV,int8 (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool +Rego 3000/UI800/WSW196i/BC400,thermostat,253,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp Rego 3000/UI800/WSW196i/BC400,thermostat,253,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate Rego 3000/UI800/WSW196i/BC400,thermostat,253,mode,mode,enum [off\|manual\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode Rego 3000/UI800/WSW196i/BC400,thermostat,253,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype -Rego 3000/UI800/WSW196i/BC400,thermostat,253,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp -Rego 3000/UI800/WSW196i/BC400,thermostat,253,manualtemp,manual temperature,uint (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp -Rego 3000/UI800/WSW196i/BC400,thermostat,253,comforttemp,comfort temperature,uint (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp -Rego 3000/UI800/WSW196i/BC400,thermostat,253,summertemp,summer temperature,uint (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp -Rego 3000/UI800/WSW196i/BC400,thermostat,253,designtemp,design temperature,uint (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp -Rego 3000/UI800/WSW196i/BC400,thermostat,253,offsettemp,offset temperature,int (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp -Rego 3000/UI800/WSW196i/BC400,thermostat,253,minflowtemp,min flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp -Rego 3000/UI800/WSW196i/BC400,thermostat,253,maxflowtemp,max flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp -Rego 3000/UI800/WSW196i/BC400,thermostat,253,roominfluence,room influence,uint (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence -Rego 3000/UI800/WSW196i/BC400,thermostat,253,roominflfactor,room influence factor,uint (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor -Rego 3000/UI800/WSW196i/BC400,thermostat,253,curroominfl,current room influence,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl +Rego 3000/UI800/WSW196i/BC400,thermostat,253,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,manualtemp,manual temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,comforttemp,comfort temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,designtemp,design temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,offsettemp,offset temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,roominfluence,room influence,uint8 (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence +Rego 3000/UI800/WSW196i/BC400,thermostat,253,roominflfactor,room influence factor,uint8 (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor +Rego 3000/UI800/WSW196i/BC400,thermostat,253,curroominfl,current room influence,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl Rego 3000/UI800/WSW196i/BC400,thermostat,253,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode -Rego 3000/UI800/WSW196i/BC400,thermostat,253,nofrosttemp,nofrost temperature,int (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp -Rego 3000/UI800/WSW196i/BC400,thermostat,253,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,nofrosttemp,nofrost temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp Rego 3000/UI800/WSW196i/BC400,thermostat,253,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype Rego 3000/UI800/WSW196i/BC400,thermostat,253,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode Rego 3000/UI800/WSW196i/BC400,thermostat,253,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode @@ -4019,93 +4103,92 @@ Rego 3000/UI800/WSW196i/BC400,thermostat,253,summermode,summer mode,enum [winter Rego 3000/UI800/WSW196i/BC400,thermostat,253,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate Rego 3000/UI800/WSW196i/BC400,thermostat,253,controlmode,control mode,enum [weather compensated\|outside basepoint\|n/a\|room\|power\|constant], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode Rego 3000/UI800/WSW196i/BC400,thermostat,253,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program -Rego 3000/UI800/WSW196i/BC400,thermostat,253,tempautotemp,temporary set temperature automode,int (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp -Rego 3000/UI800/WSW196i/BC400,thermostat,253,remoteseltemp,temporary set temperature from remote,int (>=-63<=63),C,false,sensor.thermostat_hc1_temporary_set_temperature_from_remote,sensor.thermostat_hc1_remoteseltemp -Rego 3000/UI800/WSW196i/BC400,thermostat,253,fastheatup,fast heatup,uint (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup +Rego 3000/UI800/WSW196i/BC400,thermostat,253,tempautotemp,temporary set temperature automode,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,remoteseltemp,temporary set temperature from remote,int8 (>=-63<=63),C,false,sensor.thermostat_hc1_temporary_set_temperature_from_remote,sensor.thermostat_hc1_remoteseltemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,fastheatup,fast heatup,uint8 (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup Rego 3000/UI800/WSW196i/BC400,thermostat,253,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization Rego 3000/UI800/WSW196i/BC400,thermostat,253,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode -Rego 3000/UI800/WSW196i/BC400,thermostat,253,noreducetemp,no reduce below temperature,int (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp -Rego 3000/UI800/WSW196i/BC400,thermostat,253,reducetemp,off/reduce switch temperature,int (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp -Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_wwprio +Rego 3000/UI800/WSW196i/BC400,thermostat,253,noreducetemp,no reduce below temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,reducetemp,off/reduce switch temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,dhwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_dhwprio Rego 3000/UI800/WSW196i/BC400,thermostat,253,cooling,cooling,boolean, ,true,switch.thermostat_hc1_cooling,switch.thermostat_hc1_cooling Rego 3000/UI800/WSW196i/BC400,thermostat,253,coolingon,cooling,boolean, ,false,binary_sensor.thermostat_hc1_cooling,binary_sensor.thermostat_hc1_coolingon Rego 3000/UI800/WSW196i/BC400,thermostat,253,hpmode,HP Mode,enum [heating\|cooling\|heating&cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode -Rego 3000/UI800/WSW196i/BC400,thermostat,253,dewoffset,dew point offset,uint (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset -Rego 3000/UI800/WSW196i/BC400,thermostat,253,roomtempdiff,room temp difference,uint (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff -Rego 3000/UI800/WSW196i/BC400,thermostat,253,hpminflowtemp,HP min. flow temp.,uint (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,dewoffset,dew point offset,uint8 (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset +Rego 3000/UI800/WSW196i/BC400,thermostat,253,roomtempdiff,room temp difference,uint8 (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff +Rego 3000/UI800/WSW196i/BC400,thermostat,253,hpminflowtemp,HP min. flow temp.,uint8 (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp Rego 3000/UI800/WSW196i/BC400,thermostat,253,control,control device,enum [RC310\|RC200\|RC100\|RC100H\|TC100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control -Rego 3000/UI800/WSW196i/BC400,thermostat,253,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp -Rego 3000/UI800/WSW196i/BC400,thermostat,253,remotehum,room humidity from remote,uint (>=-1<=101),%,true,number.thermostat_hc1_room_humidity_from_remote,number.thermostat_hc1_remotehum -Rego 3000/UI800/WSW196i/BC400,thermostat,253,heatondelay,heat-on delay,uint (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay -Rego 3000/UI800/WSW196i/BC400,thermostat,253,heatoffdelay,heat-off delay,uint (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay -Rego 3000/UI800/WSW196i/BC400,thermostat,253,instantstart,instant start,uint (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart +Rego 3000/UI800/WSW196i/BC400,thermostat,253,remotetemp,room temperature from remote,int16 (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,remotehum,room humidity from remote,uint8 (>=-1<=101),%,true,number.thermostat_hc1_room_humidity_from_remote,number.thermostat_hc1_remotehum +Rego 3000/UI800/WSW196i/BC400,thermostat,253,heatondelay,heat-on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay +Rego 3000/UI800/WSW196i/BC400,thermostat,253,heatoffdelay,heat-off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay +Rego 3000/UI800/WSW196i/BC400,thermostat,253,instantstart,instant start,uint8 (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart Rego 3000/UI800/WSW196i/BC400,thermostat,253,boost,boost mode,boolean, ,true,switch.thermostat_hc1_boost_mode,switch.thermostat_hc1_boost -Rego 3000/UI800/WSW196i/BC400,thermostat,253,boosttime,boost time,uint (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime +Rego 3000/UI800/WSW196i/BC400,thermostat,253,boosttime,boost time,uint8 (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime +Rego 3000/UI800/WSW196i/BC400,thermostat,253,mode,mode,enum [off\|eco+\|eco\|comfort\|auto], ,true,select.thermostat_dhw_mode,select.thermostat_dhw_mode +Rego 3000/UI800/WSW196i/BC400,thermostat,253,settemp,set temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_temperature,number.thermostat_dhw_settemp +Rego 3000/UI800/WSW196i/BC400,thermostat,253,settemplow,set low temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_low_temperature,number.thermostat_dhw_settemplow +Rego 3000/UI800/WSW196i/BC400,thermostat,253,circmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_dhw_circulation_pump_mode,select.thermostat_dhw_circmode +Rego 3000/UI800/WSW196i/BC400,thermostat,253,chargeduration,charge duration,uint8 (>=0<=3810),minutes,true,number.thermostat_dhw_charge_duration,number.thermostat_dhw_chargeduration +Rego 3000/UI800/WSW196i/BC400,thermostat,253,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge +Rego 3000/UI800/WSW196i/BC400,thermostat,253,extra,extra,uint8 (>=0<=254),C,false,sensor.thermostat_dhw_extra,sensor.thermostat_dhw_extra +Rego 3000/UI800/WSW196i/BC400,thermostat,253,disinfecting,disinfecting,boolean, ,true,switch.thermostat_dhw_disinfecting,switch.thermostat_dhw_disinfecting +Rego 3000/UI800/WSW196i/BC400,thermostat,253,disinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_dhw_disinfection_day,select.thermostat_dhw_disinfectday +Rego 3000/UI800/WSW196i/BC400,thermostat,253,disinfecttime,disinfection time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_disinfection_time,number.thermostat_dhw_disinfecttime +Rego 3000/UI800/WSW196i/BC400,thermostat,253,dailyheating,daily heating,boolean, ,true,switch.thermostat_dhw_daily_heating,switch.thermostat_dhw_dailyheating +Rego 3000/UI800/WSW196i/BC400,thermostat,253,dailyheattime,daily heating time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_daily_heating_time,number.thermostat_dhw_dailyheattime ES72/RC20,thermostat,66,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode ES72/RC20,thermostat,66,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode ES72/RC20,thermostat,66,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime -ES72/RC20,thermostat,66,minexttemp,minimal external temperature,int (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp -ES72/RC20,thermostat,66,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -ES72/RC20,thermostat,66,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +ES72/RC20,thermostat,66,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp +ES72/RC20,thermostat,66,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +ES72/RC20,thermostat,66,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp ES72/RC20,thermostat,66,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate ES72/RC20,thermostat,66,mode,mode,enum [night\|day\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode ES72/RC20,thermostat,66,modetype,mode type,enum [night\|day], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype -ES72/RC20,thermostat,66,daytemp,day temperature,uint (>=0<=127),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp -ES72/RC20,thermostat,66,nighttemp,night temperature,uint (>=0<=127),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp +ES72/RC20,thermostat,66,daytemp,day temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp +ES72/RC20,thermostat,66,nighttemp,night temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp ES72/RC20,thermostat,66,program,program,enum [family\|morning\|evening\|am\|pm\|midday\|singles\|seniors], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program -ES72/RC20,thermostat,66,minflowtemp,min flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp -ES72/RC20,thermostat,66,maxflowtemp,max flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp -ES72/RC20,thermostat,66,tempautotemp,temporary set temperature automode,uint (>=0<=127),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp +ES72/RC20,thermostat,66,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp +ES72/RC20,thermostat,66,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp +ES72/RC20,thermostat,66,tempautotemp,temporary set temperature automode,uint8 (>=0<=127),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp ES72/RC20,thermostat,66,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype -ES72/RC20,thermostat,66,summertemp,summer temperature,uint (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp +ES72/RC20,thermostat,66,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp ES72/RC20,thermostat,66,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode -ES72/RC20,thermostat,66,remotetemp,room temperature from remote,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp +ES72/RC20,thermostat,66,remotetemp,room temperature from remote,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp ES73,thermostat,76,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode ES73,thermostat,76,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode ES73,thermostat,76,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime -ES73,thermostat,76,display,display,enum [internal temperature\|internal setpoint\|external temperature\|burner temperature\|ww temperature\|functioning mode\|time\|date\|smoke temperature], ,true,select.thermostat_display,select.thermostat_display +ES73,thermostat,76,display,display,enum [internal temperature\|internal setpoint\|external temperature\|burner temperature\|dhw temperature\|functioning mode\|time\|date\|smoke temperature], ,true,select.thermostat_display,select.thermostat_display ES73,thermostat,76,language,language,enum [german\|dutch\|french\|italian], ,false,sensor.thermostat_language,sensor.thermostat_language -ES73,thermostat,76,clockoffset,clock offset,int (>=-126<=126),seconds,true,number.thermostat_clock_offset,number.thermostat_clockoffset -ES73,thermostat,76,intoffset,internal temperature offset,int (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset -ES73,thermostat,76,minexttemp,minimal external temperature,int (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp -ES73,thermostat,76,inttemp1,temperature sensor 1,short (>=-3199<=3199),C,false,sensor.thermostat_temperature_sensor_1,sensor.thermostat_inttemp1 -ES73,thermostat,76,inttemp2,temperature sensor 2,short (>=-3199<=3199),C,false,sensor.thermostat_temperature_sensor_2,sensor.thermostat_inttemp2 +ES73,thermostat,76,clockoffset,clock offset,int8 (>=-126<=126),seconds,true,number.thermostat_clock_offset,number.thermostat_clockoffset +ES73,thermostat,76,intoffset,internal temperature offset,int8 (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset +ES73,thermostat,76,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp +ES73,thermostat,76,inttemp1,temperature sensor 1,int16 (>=-3199<=3199),C,false,sensor.thermostat_temperature_sensor_1,sensor.thermostat_inttemp1 +ES73,thermostat,76,inttemp2,temperature sensor 2,int16 (>=-3199<=3199),C,false,sensor.thermostat_temperature_sensor_2,sensor.thermostat_inttemp2 ES73,thermostat,76,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping -ES73,thermostat,76,dampedoutdoortemp,damped outdoor temperature,int (>=-126<=126),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp +ES73,thermostat,76,dampedoutdoortemp,damped outdoor temperature,int8 (>=-126<=126),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp ES73,thermostat,76,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building -ES73,thermostat,76,wwmode,mode,enum [off\|on\|auto], ,true,select.thermostat_mode,select.thermostat_wwmode -ES73,thermostat,76,wwcircmode,circulation pump mode,enum [off\|on\|auto], ,true,select.thermostat_circulation_pump_mode,select.thermostat_wwcircmode -ES73,thermostat,76,wwprogmode,program,enum [std prog\|own prog], ,true,select.thermostat_program,select.thermostat_wwprogmode -ES73,thermostat,76,wwcircprog,circulation program,enum [std prog\|own prog], ,true,select.thermostat_circulation_program,select.thermostat_wwcircprog -ES73,thermostat,76,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_disinfecting,switch.thermostat_wwdisinfecting -ES73,thermostat,76,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_disinfection_day,select.thermostat_wwdisinfectday -ES73,thermostat,76,wwdisinfecthour,disinfection hour,uint (>=0<=23), ,true,number.thermostat_disinfection_hour,number.thermostat_wwdisinfecthour -ES73,thermostat,76,wwmaxtemp,maximum temperature,uint (>=0<=254),C,true,number.thermostat_maximum_temperature,number.thermostat_wwmaxtemp -ES73,thermostat,76,wwonetimekey,one time key function,boolean, ,true,switch.thermostat_one_time_key_function,switch.thermostat_wwonetimekey -ES73,thermostat,76,wwswitchtime,program switchtime,string, ,true,sensor.thermostat_program_switchtime,sensor.thermostat_wwswitchtime -ES73,thermostat,76,wwcircswitchtime,circulation program switchtime,string, ,true,sensor.thermostat_circulation_program_switchtime,sensor.thermostat_wwcircswitchtime -ES73,thermostat,76,wwholidays,holiday dates,string, ,true,sensor.thermostat_holiday_dates,sensor.thermostat_wwholidays -ES73,thermostat,76,wwvacations,vacation dates,string, ,true,sensor.thermostat_vacation_dates,sensor.thermostat_wwvacations -ES73,thermostat,76,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -ES73,thermostat,76,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +ES73,thermostat,76,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +ES73,thermostat,76,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp ES73,thermostat,76,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate ES73,thermostat,76,mode,mode,enum [night\|day\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode ES73,thermostat,76,modetype,mode type,enum [night\|day], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype -ES73,thermostat,76,daytemp,day temperature,uint (>=10<=30),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp -ES73,thermostat,76,nighttemp,night temperature,uint (>=10<=30),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp -ES73,thermostat,76,designtemp,design temperature,uint (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp -ES73,thermostat,76,offsettemp,offset temperature,int (>=-5<=5),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp -ES73,thermostat,76,holidaytemp,holiday temperature,uint (>=5<=30),C,true,number.thermostat_hc1_holiday_temperature,number.thermostat_hc1_holidaytemp -ES73,thermostat,76,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp -ES73,thermostat,76,summertemp,summer temperature,uint (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp +ES73,thermostat,76,daytemp,day temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp +ES73,thermostat,76,nighttemp,night temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp +ES73,thermostat,76,designtemp,design temperature,uint8 (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp +ES73,thermostat,76,offsettemp,offset temperature,int8 (>=-5<=5),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp +ES73,thermostat,76,holidaytemp,holiday temperature,uint8 (>=5<=30),C,true,number.thermostat_hc1_holiday_temperature,number.thermostat_hc1_holidaytemp +ES73,thermostat,76,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp +ES73,thermostat,76,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp ES73,thermostat,76,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode ES73,thermostat,76,holidaymode,holiday mode,boolean, ,false,binary_sensor.thermostat_hc1_holiday_mode,binary_sensor.thermostat_hc1_holidaymode -ES73,thermostat,76,nofrosttemp,nofrost temperature,int (>=-20<=10),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp +ES73,thermostat,76,nofrosttemp,nofrost temperature,int8 (>=-20<=10),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp ES73,thermostat,76,nofrostmode,nofrost mode,enum [off\|outdoor\|room], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode -ES73,thermostat,76,roominfluence,room influence,uint (>=0<=10),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence -ES73,thermostat,76,minflowtemp,min flow temperature,uint (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp -ES73,thermostat,76,maxflowtemp,max flow temperature,uint (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp -ES73,thermostat,76,flowtempoffset,flow temperature offset for mixer,uint (>=0<=20),C,true,number.thermostat_hc1_flow_temperature_offset_for_mixer,number.thermostat_hc1_flowtempoffset +ES73,thermostat,76,roominfluence,room influence,uint8 (>=0<=10),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence +ES73,thermostat,76,minflowtemp,min flow temperature,uint8 (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp +ES73,thermostat,76,maxflowtemp,max flow temperature,uint8 (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp +ES73,thermostat,76,flowtempoffset,flow temperature offset for mixer,uint8 (>=0<=20),C,true,number.thermostat_hc1_flow_temperature_offset_for_mixer,number.thermostat_hc1_flowtempoffset ES73,thermostat,76,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype ES73,thermostat,76,reducemode,reduce mode,enum [nofrost\|reduce\|room\|outdoor], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode ES73,thermostat,76,controlmode,control mode,enum [outdoor\|room], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode @@ -4113,80 +4196,80 @@ ES73,thermostat,76,control,control device,enum [off\|RC20\|RC3x], ,true,select.t ES73,thermostat,76,holidays,holiday dates,string, ,true,sensor.thermostat_hc1_holiday_dates,sensor.thermostat_hc1_holidays ES73,thermostat,76,vacations,vacation dates,string, ,true,sensor.thermostat_hc1_vacation_dates,sensor.thermostat_hc1_vacations ES73,thermostat,76,program,program,enum [own 1\|family\|morning\|evening\|am\|pm\|midday\|singles\|seniors\|new\|own 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program -ES73,thermostat,76,pause,pause time,uint (>=0<=99),hours,true,number.thermostat_hc1_pause_time,number.thermostat_hc1_pause -ES73,thermostat,76,party,party time,uint (>=0<=99),hours,true,number.thermostat_hc1_party_time,number.thermostat_hc1_party -ES73,thermostat,76,tempautotemp,temporary set temperature automode,uint (>=0<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp -ES73,thermostat,76,noreducetemp,no reduce below temperature,int (>=-31<=10),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp -ES73,thermostat,76,reducetemp,off/reduce switch temperature,int (>=-20<=10),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp -ES73,thermostat,76,vacreducetemp,vacations off/reduce switch temperature,int (>=-20<=10),C,true,number.thermostat_hc1_vacations_off/reduce_switch_temperature,number.thermostat_hc1_vacreducetemp +ES73,thermostat,76,pause,pause time,uint8 (>=0<=99),hours,true,number.thermostat_hc1_pause_time,number.thermostat_hc1_pause +ES73,thermostat,76,party,party time,uint8 (>=0<=99),hours,true,number.thermostat_hc1_party_time,number.thermostat_hc1_party +ES73,thermostat,76,tempautotemp,temporary set temperature automode,uint8 (>=0<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp +ES73,thermostat,76,noreducetemp,no reduce below temperature,int8 (>=-31<=10),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp +ES73,thermostat,76,reducetemp,off/reduce switch temperature,int8 (>=-20<=10),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp +ES73,thermostat,76,vacreducetemp,vacations off/reduce switch temperature,int8 (>=-20<=10),C,true,number.thermostat_hc1_vacations_off/reduce_switch_temperature,number.thermostat_hc1_vacreducetemp ES73,thermostat,76,vacreducemode,vacations reduce mode,enum [nofrost\|reduce\|room\|outdoor], ,true,select.thermostat_hc1_vacations_reduce_mode,select.thermostat_hc1_vacreducemode -ES73,thermostat,76,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp -ES73,thermostat,76,wwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_wwprio +ES73,thermostat,76,remotetemp,room temperature from remote,int16 (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp +ES73,thermostat,76,dhwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_dhwprio ES73,thermostat,76,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization ES73,thermostat,76,switchtime1,own1 program switchtime,string, ,true,sensor.thermostat_hc1_own1_program_switchtime,sensor.thermostat_hc1_switchtime1 ES73,thermostat,76,switchtime2,own2 program switchtime,string, ,true,sensor.thermostat_hc1_own2_program_switchtime,sensor.thermostat_hc1_switchtime2 +ES73,thermostat,76,mode,mode,enum [off\|on\|auto], ,true,select.thermostat_dhw_mode,select.thermostat_dhw_mode +ES73,thermostat,76,circmode,circulation pump mode,enum [off\|on\|auto], ,true,select.thermostat_dhw_circulation_pump_mode,select.thermostat_dhw_circmode +ES73,thermostat,76,progmode,program,enum [std prog\|own prog], ,true,select.thermostat_dhw_program,select.thermostat_dhw_progmode +ES73,thermostat,76,circprog,circulation program,enum [std prog\|own prog], ,true,select.thermostat_dhw_circulation_program,select.thermostat_dhw_circprog +ES73,thermostat,76,disinfecting,disinfecting,boolean, ,true,switch.thermostat_dhw_disinfecting,switch.thermostat_dhw_disinfecting +ES73,thermostat,76,disinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_dhw_disinfection_day,select.thermostat_dhw_disinfectday +ES73,thermostat,76,disinfecthour,disinfection hour,uint8 (>=0<=23), ,true,number.thermostat_dhw_disinfection_hour,number.thermostat_dhw_disinfecthour +ES73,thermostat,76,maxtemp,maximum temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_maximum_temperature,number.thermostat_dhw_maxtemp +ES73,thermostat,76,onetimekey,one time key function,boolean, ,true,switch.thermostat_dhw_one_time_key_function,switch.thermostat_dhw_onetimekey +ES73,thermostat,76,switchtime,program switchtime,string, ,true,sensor.thermostat_dhw_program_switchtime,sensor.thermostat_dhw_switchtime +ES73,thermostat,76,circswitchtime,circulation program switchtime,string, ,true,sensor.thermostat_dhw_circulation_program_switchtime,sensor.thermostat_dhw_circswitchtime +ES73,thermostat,76,holidays,holiday dates,string, ,true,sensor.thermostat_dhw_holiday_dates,sensor.thermostat_dhw_holidays +ES73,thermostat,76,vacations,vacation dates,string, ,true,sensor.thermostat_dhw_vacation_dates,sensor.thermostat_dhw_vacations ES72/RC20,thermostat,113,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode ES72/RC20,thermostat,113,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode ES72/RC20,thermostat,113,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime -ES72/RC20,thermostat,113,minexttemp,minimal external temperature,int (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp -ES72/RC20,thermostat,113,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -ES72/RC20,thermostat,113,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +ES72/RC20,thermostat,113,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp +ES72/RC20,thermostat,113,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +ES72/RC20,thermostat,113,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp ES72/RC20,thermostat,113,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate ES72/RC20,thermostat,113,mode,mode,enum [night\|day\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode ES72/RC20,thermostat,113,modetype,mode type,enum [night\|day], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype -ES72/RC20,thermostat,113,daytemp,day temperature,uint (>=0<=127),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp -ES72/RC20,thermostat,113,nighttemp,night temperature,uint (>=0<=127),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp +ES72/RC20,thermostat,113,daytemp,day temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp +ES72/RC20,thermostat,113,nighttemp,night temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp ES72/RC20,thermostat,113,program,program,enum [family\|morning\|evening\|am\|pm\|midday\|singles\|seniors], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program -ES72/RC20,thermostat,113,minflowtemp,min flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp -ES72/RC20,thermostat,113,maxflowtemp,max flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp -ES72/RC20,thermostat,113,tempautotemp,temporary set temperature automode,uint (>=0<=127),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp +ES72/RC20,thermostat,113,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp +ES72/RC20,thermostat,113,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp +ES72/RC20,thermostat,113,tempautotemp,temporary set temperature automode,uint8 (>=0<=127),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp ES72/RC20,thermostat,113,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype -ES72/RC20,thermostat,113,summertemp,summer temperature,uint (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp +ES72/RC20,thermostat,113,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp ES72/RC20,thermostat,113,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode -ES72/RC20,thermostat,113,remotetemp,room temperature from remote,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp +ES72/RC20,thermostat,113,remotetemp,room temperature from remote,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp ES79,thermostat,156,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode ES79,thermostat,156,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode ES79,thermostat,156,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime -ES79,thermostat,156,intoffset,internal temperature offset,int (>=-5<=5),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset -ES79,thermostat,156,minexttemp,minimal external temperature,int (>=-30<=0),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp -ES79,thermostat,156,inttemp1,temperature sensor 1,short (>=-3199<=3199),C,false,sensor.thermostat_temperature_sensor_1,sensor.thermostat_inttemp1 -ES79,thermostat,156,inttemp2,temperature sensor 2,short (>=-3199<=3199),C,false,sensor.thermostat_temperature_sensor_2,sensor.thermostat_inttemp2 +ES79,thermostat,156,intoffset,internal temperature offset,int8 (>=-5<=5),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset +ES79,thermostat,156,minexttemp,minimal external temperature,int8 (>=-30<=0),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp +ES79,thermostat,156,inttemp1,temperature sensor 1,int16 (>=-3199<=3199),C,false,sensor.thermostat_temperature_sensor_1,sensor.thermostat_inttemp1 +ES79,thermostat,156,inttemp2,temperature sensor 2,int16 (>=-3199<=3199),C,false,sensor.thermostat_temperature_sensor_2,sensor.thermostat_inttemp2 ES79,thermostat,156,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping -ES79,thermostat,156,dampedoutdoortemp,damped outdoor temperature,int (>=-126<=126),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp +ES79,thermostat,156,dampedoutdoortemp,damped outdoor temperature,int8 (>=-126<=126),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp ES79,thermostat,156,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building -ES79,thermostat,156,wwmode,mode,enum [off\|on\|auto], ,true,select.thermostat_mode,select.thermostat_wwmode -ES79,thermostat,156,wwcircmode,circulation pump mode,enum [off\|on\|auto], ,true,select.thermostat_circulation_pump_mode,select.thermostat_wwcircmode -ES79,thermostat,156,wwprogmode,program,enum [std prog\|own prog], ,true,select.thermostat_program,select.thermostat_wwprogmode -ES79,thermostat,156,wwcircprog,circulation program,enum [std prog\|own prog], ,true,select.thermostat_circulation_program,select.thermostat_wwcircprog -ES79,thermostat,156,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_disinfecting,switch.thermostat_wwdisinfecting -ES79,thermostat,156,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_disinfection_day,select.thermostat_wwdisinfectday -ES79,thermostat,156,wwdisinfecthour,disinfection hour,uint (>=0<=23), ,true,number.thermostat_disinfection_hour,number.thermostat_wwdisinfecthour -ES79,thermostat,156,wwmaxtemp,maximum temperature,uint (>=60<=80),C,true,number.thermostat_maximum_temperature,number.thermostat_wwmaxtemp -ES79,thermostat,156,wwonetimekey,one time key function,boolean, ,true,switch.thermostat_one_time_key_function,switch.thermostat_wwonetimekey -ES79,thermostat,156,wwswitchtime,program switchtime,string, ,true,sensor.thermostat_program_switchtime,sensor.thermostat_wwswitchtime -ES79,thermostat,156,wwcircswitchtime,circulation program switchtime,string, ,true,sensor.thermostat_circulation_program_switchtime,sensor.thermostat_wwcircswitchtime -ES79,thermostat,156,wwholidays,holiday dates,string, ,true,sensor.thermostat_holiday_dates,sensor.thermostat_wwholidays -ES79,thermostat,156,wwvacations,vacation dates,string, ,true,sensor.thermostat_vacation_dates,sensor.thermostat_wwvacations -ES79,thermostat,156,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -ES79,thermostat,156,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +ES79,thermostat,156,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +ES79,thermostat,156,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp ES79,thermostat,156,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate ES79,thermostat,156,mode,mode,enum [night\|day\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode ES79,thermostat,156,modetype,mode type,enum [night\|day], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype -ES79,thermostat,156,daytemp,day temperature,uint (>=10<=30),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp -ES79,thermostat,156,nighttemp,night temperature,uint (>=10<=30),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp -ES79,thermostat,156,designtemp,design temperature,uint (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp -ES79,thermostat,156,offsettemp,offset temperature,int (>=-5<=5),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp -ES79,thermostat,156,holidaytemp,holiday temperature,uint (>=5<=30),C,true,number.thermostat_hc1_holiday_temperature,number.thermostat_hc1_holidaytemp -ES79,thermostat,156,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp -ES79,thermostat,156,summertemp,summer temperature,uint (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp +ES79,thermostat,156,daytemp,day temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp +ES79,thermostat,156,nighttemp,night temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp +ES79,thermostat,156,designtemp,design temperature,uint8 (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp +ES79,thermostat,156,offsettemp,offset temperature,int8 (>=-5<=5),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp +ES79,thermostat,156,holidaytemp,holiday temperature,uint8 (>=5<=30),C,true,number.thermostat_hc1_holiday_temperature,number.thermostat_hc1_holidaytemp +ES79,thermostat,156,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp +ES79,thermostat,156,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp ES79,thermostat,156,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode ES79,thermostat,156,holidaymode,holiday mode,boolean, ,false,binary_sensor.thermostat_hc1_holiday_mode,binary_sensor.thermostat_hc1_holidaymode -ES79,thermostat,156,nofrosttemp,nofrost temperature,int (>=-20<=10),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp +ES79,thermostat,156,nofrosttemp,nofrost temperature,int8 (>=-20<=10),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp ES79,thermostat,156,nofrostmode,nofrost mode,enum [off\|outdoor\|room], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode -ES79,thermostat,156,roominfluence,room influence,uint (>=0<=10),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence -ES79,thermostat,156,minflowtemp,min flow temperature,uint (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp -ES79,thermostat,156,maxflowtemp,max flow temperature,uint (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp -ES79,thermostat,156,flowtempoffset,flow temperature offset for mixer,uint (>=0<=20),C,true,number.thermostat_hc1_flow_temperature_offset_for_mixer,number.thermostat_hc1_flowtempoffset +ES79,thermostat,156,roominfluence,room influence,uint8 (>=0<=10),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence +ES79,thermostat,156,minflowtemp,min flow temperature,uint8 (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp +ES79,thermostat,156,maxflowtemp,max flow temperature,uint8 (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp +ES79,thermostat,156,flowtempoffset,flow temperature offset for mixer,uint8 (>=0<=20),C,true,number.thermostat_hc1_flow_temperature_offset_for_mixer,number.thermostat_hc1_flowtempoffset ES79,thermostat,156,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype ES79,thermostat,156,reducemode,reduce mode,enum [nofrost\|reduce\|room\|outdoor], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode ES79,thermostat,156,controlmode,control mode,enum [outdoor\|room], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode @@ -4194,531 +4277,544 @@ ES79,thermostat,156,control,control device,enum [off\|RC20\|RC3x], ,true,select. ES79,thermostat,156,holidays,holiday dates,string, ,true,sensor.thermostat_hc1_holiday_dates,sensor.thermostat_hc1_holidays ES79,thermostat,156,vacations,vacation dates,string, ,true,sensor.thermostat_hc1_vacation_dates,sensor.thermostat_hc1_vacations ES79,thermostat,156,program,program,enum [own 1\|family\|morning\|evening\|am\|pm\|midday\|singles\|seniors\|new\|own 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program -ES79,thermostat,156,pause,pause time,uint (>=0<=99),hours,true,number.thermostat_hc1_pause_time,number.thermostat_hc1_pause -ES79,thermostat,156,party,party time,uint (>=0<=99),hours,true,number.thermostat_hc1_party_time,number.thermostat_hc1_party -ES79,thermostat,156,tempautotemp,temporary set temperature automode,uint (>=0<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp -ES79,thermostat,156,noreducetemp,no reduce below temperature,int (>=-31<=10),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp -ES79,thermostat,156,reducetemp,off/reduce switch temperature,int (>=-20<=10),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp -ES79,thermostat,156,vacreducetemp,vacations off/reduce switch temperature,int (>=-20<=10),C,true,number.thermostat_hc1_vacations_off/reduce_switch_temperature,number.thermostat_hc1_vacreducetemp +ES79,thermostat,156,pause,pause time,uint8 (>=0<=99),hours,true,number.thermostat_hc1_pause_time,number.thermostat_hc1_pause +ES79,thermostat,156,party,party time,uint8 (>=0<=99),hours,true,number.thermostat_hc1_party_time,number.thermostat_hc1_party +ES79,thermostat,156,tempautotemp,temporary set temperature automode,uint8 (>=0<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp +ES79,thermostat,156,noreducetemp,no reduce below temperature,int8 (>=-31<=10),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp +ES79,thermostat,156,reducetemp,off/reduce switch temperature,int8 (>=-20<=10),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp +ES79,thermostat,156,vacreducetemp,vacations off/reduce switch temperature,int8 (>=-20<=10),C,true,number.thermostat_hc1_vacations_off/reduce_switch_temperature,number.thermostat_hc1_vacreducetemp ES79,thermostat,156,vacreducemode,vacations reduce mode,enum [nofrost\|reduce\|room\|outdoor], ,true,select.thermostat_hc1_vacations_reduce_mode,select.thermostat_hc1_vacreducemode -ES79,thermostat,156,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp -ES79,thermostat,156,wwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_wwprio +ES79,thermostat,156,remotetemp,room temperature from remote,int16 (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp +ES79,thermostat,156,dhwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_dhwprio ES79,thermostat,156,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization ES79,thermostat,156,switchtime1,own1 program switchtime,string, ,true,sensor.thermostat_hc1_own1_program_switchtime,sensor.thermostat_hc1_switchtime1 ES79,thermostat,156,switchtime2,own2 program switchtime,string, ,true,sensor.thermostat_hc1_own2_program_switchtime,sensor.thermostat_hc1_switchtime2 +ES79,thermostat,156,mode,mode,enum [off\|on\|auto], ,true,select.thermostat_dhw_mode,select.thermostat_dhw_mode +ES79,thermostat,156,circmode,circulation pump mode,enum [off\|on\|auto], ,true,select.thermostat_dhw_circulation_pump_mode,select.thermostat_dhw_circmode +ES79,thermostat,156,progmode,program,enum [std prog\|own prog], ,true,select.thermostat_dhw_program,select.thermostat_dhw_progmode +ES79,thermostat,156,circprog,circulation program,enum [std prog\|own prog], ,true,select.thermostat_dhw_circulation_program,select.thermostat_dhw_circprog +ES79,thermostat,156,disinfecting,disinfecting,boolean, ,true,switch.thermostat_dhw_disinfecting,switch.thermostat_dhw_disinfecting +ES79,thermostat,156,disinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_dhw_disinfection_day,select.thermostat_dhw_disinfectday +ES79,thermostat,156,disinfecthour,disinfection hour,uint8 (>=0<=23), ,true,number.thermostat_dhw_disinfection_hour,number.thermostat_dhw_disinfecthour +ES79,thermostat,156,maxtemp,maximum temperature,uint8 (>=60<=80),C,true,number.thermostat_dhw_maximum_temperature,number.thermostat_dhw_maxtemp +ES79,thermostat,156,onetimekey,one time key function,boolean, ,true,switch.thermostat_dhw_one_time_key_function,switch.thermostat_dhw_onetimekey +ES79,thermostat,156,switchtime,program switchtime,string, ,true,sensor.thermostat_dhw_program_switchtime,sensor.thermostat_dhw_switchtime +ES79,thermostat,156,circswitchtime,circulation program switchtime,string, ,true,sensor.thermostat_dhw_circulation_program_switchtime,sensor.thermostat_dhw_circswitchtime +ES79,thermostat,156,holidays,holiday dates,string, ,true,sensor.thermostat_dhw_holiday_dates,sensor.thermostat_dhw_holidays +ES79,thermostat,156,vacations,vacation dates,string, ,true,sensor.thermostat_dhw_vacation_dates,sensor.thermostat_dhw_vacations FW100,thermostat,105,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode FW100,thermostat,105,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode FW100,thermostat,105,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime FW100,thermostat,105,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy -FW100,thermostat,105,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp -FW100,thermostat,105,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio -FW100,thermostat,105,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor -FW100,thermostat,105,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor -FW100,thermostat,105,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler -FW100,thermostat,105,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler -FW100,thermostat,105,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge -FW100,thermostat,105,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -FW100,thermostat,105,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +FW100,thermostat,105,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp +FW100,thermostat,105,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio +FW100,thermostat,105,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor +FW100,thermostat,105,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor +FW100,thermostat,105,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler +FW100,thermostat,105,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler +FW100,thermostat,105,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +FW100,thermostat,105,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp FW100,thermostat,105,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate FW100,thermostat,105,mode,mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode FW100,thermostat,105,modetype,mode type,enum [nofrost\|eco\|heat], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype -FW100,thermostat,105,heattemp,heat temperature,uint (>=0<=127),C,true,number.thermostat_hc1_heat_temperature,number.thermostat_hc1_heattemp -FW100,thermostat,105,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp -FW100,thermostat,105,nofrosttemp,nofrost temperature,int (>=-63<=63),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp +FW100,thermostat,105,heattemp,heat temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_heat_temperature,number.thermostat_hc1_heattemp +FW100,thermostat,105,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp +FW100,thermostat,105,nofrosttemp,nofrost temperature,int8 (>=-63<=63),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp FW100,thermostat,105,control,control device,enum [off\|FB10\|FB100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control FW100,thermostat,105,program,program,enum [prog a\|prog b\|prog c\|prog d\|prog e\|prog f], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program -FW100,thermostat,105,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp -FW100,thermostat,105,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp -FW100,thermostat,105,summertemp,summer temperature,uint (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp +FW100,thermostat,105,remotetemp,room temperature from remote,int16 (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp +FW100,thermostat,105,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp +FW100,thermostat,105,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp FW100,thermostat,105,roomsensor,room sensor,enum [extern\|intern\|auto], ,true,select.thermostat_hc1_room_sensor,select.thermostat_hc1_roomsensor FW100,thermostat,105,holidaymode,holiday mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_holiday_mode,select.thermostat_hc1_holidaymode FW100,thermostat,105,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization FW100,thermostat,105,heatup,heatup,enum [slow\|medium\|fast], ,true,select.thermostat_hc1_heatup,select.thermostat_hc1_heatup -FW100,thermostat,105,minflowtemp,min flow temperature,uint (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp -FW100,thermostat,105,maxflowtemp,max flow temperature,uint (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp -FW100,thermostat,105,designtemp,design temperature,uint (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp +FW100,thermostat,105,minflowtemp,min flow temperature,uint8 (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp +FW100,thermostat,105,maxflowtemp,max flow temperature,uint8 (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp +FW100,thermostat,105,designtemp,design temperature,uint8 (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp FW100,thermostat,105,roominfluence,room influence,enum [off\|intern\|extern\|auto], ,true,select.thermostat_hc1_room_influence,select.thermostat_hc1_roominfluence -FW100,thermostat,105,roominflfactor,room influence factor,uint (>=0<=100),%,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor +FW100,thermostat,105,roominflfactor,room influence factor,uint8 (>=0<=100),%,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor FW100,thermostat,105,heatingtype,heating type,enum [off\|heatingcurve\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype FW100,thermostat,105,controlmode,control mode,enum [off\|unmixed\|unmixed IPM\|mixed IPM], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode +FW100,thermostat,105,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge FW200,thermostat,106,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode FW200,thermostat,106,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode FW200,thermostat,106,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime FW200,thermostat,106,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy -FW200,thermostat,106,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp -FW200,thermostat,106,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio -FW200,thermostat,106,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor -FW200,thermostat,106,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor -FW200,thermostat,106,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler -FW200,thermostat,106,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler -FW200,thermostat,106,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge -FW200,thermostat,106,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -FW200,thermostat,106,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +FW200,thermostat,106,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp +FW200,thermostat,106,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio +FW200,thermostat,106,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor +FW200,thermostat,106,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor +FW200,thermostat,106,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler +FW200,thermostat,106,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler +FW200,thermostat,106,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +FW200,thermostat,106,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp FW200,thermostat,106,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate FW200,thermostat,106,mode,mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode FW200,thermostat,106,modetype,mode type,enum [nofrost\|eco\|heat], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype -FW200,thermostat,106,heattemp,heat temperature,uint (>=0<=127),C,true,number.thermostat_hc1_heat_temperature,number.thermostat_hc1_heattemp -FW200,thermostat,106,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp -FW200,thermostat,106,nofrosttemp,nofrost temperature,int (>=-63<=63),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp +FW200,thermostat,106,heattemp,heat temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_heat_temperature,number.thermostat_hc1_heattemp +FW200,thermostat,106,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp +FW200,thermostat,106,nofrosttemp,nofrost temperature,int8 (>=-63<=63),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp FW200,thermostat,106,control,control device,enum [off\|FB10\|FB100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control FW200,thermostat,106,program,program,enum [prog a\|prog b\|prog c\|prog d\|prog e\|prog f], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program -FW200,thermostat,106,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp -FW200,thermostat,106,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp -FW200,thermostat,106,summertemp,summer temperature,uint (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp +FW200,thermostat,106,remotetemp,room temperature from remote,int16 (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp +FW200,thermostat,106,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp +FW200,thermostat,106,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp FW200,thermostat,106,roomsensor,room sensor,enum [extern\|intern\|auto], ,true,select.thermostat_hc1_room_sensor,select.thermostat_hc1_roomsensor FW200,thermostat,106,holidaymode,holiday mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_holiday_mode,select.thermostat_hc1_holidaymode FW200,thermostat,106,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization FW200,thermostat,106,heatup,heatup,enum [slow\|medium\|fast], ,true,select.thermostat_hc1_heatup,select.thermostat_hc1_heatup -FW200,thermostat,106,minflowtemp,min flow temperature,uint (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp -FW200,thermostat,106,maxflowtemp,max flow temperature,uint (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp -FW200,thermostat,106,designtemp,design temperature,uint (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp +FW200,thermostat,106,minflowtemp,min flow temperature,uint8 (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp +FW200,thermostat,106,maxflowtemp,max flow temperature,uint8 (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp +FW200,thermostat,106,designtemp,design temperature,uint8 (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp FW200,thermostat,106,roominfluence,room influence,enum [off\|intern\|extern\|auto], ,true,select.thermostat_hc1_room_influence,select.thermostat_hc1_roominfluence -FW200,thermostat,106,roominflfactor,room influence factor,uint (>=0<=100),%,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor +FW200,thermostat,106,roominflfactor,room influence factor,uint8 (>=0<=100),%,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor FW200,thermostat,106,heatingtype,heating type,enum [off\|heatingcurve\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype FW200,thermostat,106,controlmode,control mode,enum [off\|unmixed\|unmixed IPM\|mixed IPM], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode +FW200,thermostat,106,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge FR100,thermostat,107,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode FR100,thermostat,107,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode FR100,thermostat,107,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime FR100,thermostat,107,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy -FR100,thermostat,107,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp -FR100,thermostat,107,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio -FR100,thermostat,107,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor -FR100,thermostat,107,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor -FR100,thermostat,107,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler -FR100,thermostat,107,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler -FR100,thermostat,107,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge -FR100,thermostat,107,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -FR100,thermostat,107,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +FR100,thermostat,107,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp +FR100,thermostat,107,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio +FR100,thermostat,107,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor +FR100,thermostat,107,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor +FR100,thermostat,107,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler +FR100,thermostat,107,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler +FR100,thermostat,107,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +FR100,thermostat,107,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp FR100,thermostat,107,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate FR100,thermostat,107,mode,mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode FR100,thermostat,107,modetype,mode type,enum [nofrost\|eco\|heat], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype -FR100,thermostat,107,heattemp,heat temperature,uint (>=0<=127),C,true,number.thermostat_hc1_heat_temperature,number.thermostat_hc1_heattemp -FR100,thermostat,107,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp -FR100,thermostat,107,nofrosttemp,nofrost temperature,int (>=-63<=63),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp +FR100,thermostat,107,heattemp,heat temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_heat_temperature,number.thermostat_hc1_heattemp +FR100,thermostat,107,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp +FR100,thermostat,107,nofrosttemp,nofrost temperature,int8 (>=-63<=63),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp FR100,thermostat,107,control,control device,enum [off\|FB10\|FB100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control FR100,thermostat,107,program,program,enum [prog a\|prog b\|prog c\|prog d\|prog e\|prog f], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program -FR100,thermostat,107,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp -FR100,thermostat,107,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp -FR100,thermostat,107,summertemp,summer temperature,uint (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp +FR100,thermostat,107,remotetemp,room temperature from remote,int16 (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp +FR100,thermostat,107,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp +FR100,thermostat,107,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp FR100,thermostat,107,roomsensor,room sensor,enum [extern\|intern\|auto], ,true,select.thermostat_hc1_room_sensor,select.thermostat_hc1_roomsensor FR100,thermostat,107,holidaymode,holiday mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_holiday_mode,select.thermostat_hc1_holidaymode FR100,thermostat,107,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization FR100,thermostat,107,heatup,heatup,enum [slow\|medium\|fast], ,true,select.thermostat_hc1_heatup,select.thermostat_hc1_heatup -FR100,thermostat,107,minflowtemp,min flow temperature,uint (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp -FR100,thermostat,107,maxflowtemp,max flow temperature,uint (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp -FR100,thermostat,107,designtemp,design temperature,uint (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp +FR100,thermostat,107,minflowtemp,min flow temperature,uint8 (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp +FR100,thermostat,107,maxflowtemp,max flow temperature,uint8 (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp +FR100,thermostat,107,designtemp,design temperature,uint8 (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp FR100,thermostat,107,roominfluence,room influence,enum [off\|intern\|extern\|auto], ,true,select.thermostat_hc1_room_influence,select.thermostat_hc1_roominfluence -FR100,thermostat,107,roominflfactor,room influence factor,uint (>=0<=100),%,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor +FR100,thermostat,107,roominflfactor,room influence factor,uint8 (>=0<=100),%,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor FR100,thermostat,107,heatingtype,heating type,enum [off\|heatingcurve\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype FR100,thermostat,107,controlmode,control mode,enum [off\|unmixed\|unmixed IPM\|mixed IPM], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode +FR100,thermostat,107,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge FR110,thermostat,108,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode FR110,thermostat,108,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode FR110,thermostat,108,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime FR110,thermostat,108,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy -FR110,thermostat,108,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp -FR110,thermostat,108,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio -FR110,thermostat,108,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor -FR110,thermostat,108,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor -FR110,thermostat,108,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler -FR110,thermostat,108,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler -FR110,thermostat,108,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge -FR110,thermostat,108,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -FR110,thermostat,108,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +FR110,thermostat,108,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp +FR110,thermostat,108,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio +FR110,thermostat,108,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor +FR110,thermostat,108,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor +FR110,thermostat,108,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler +FR110,thermostat,108,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler +FR110,thermostat,108,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +FR110,thermostat,108,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp FR110,thermostat,108,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate FR110,thermostat,108,mode,mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode FR110,thermostat,108,modetype,mode type,enum [nofrost\|eco\|heat], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype -FR110,thermostat,108,heattemp,heat temperature,uint (>=0<=127),C,true,number.thermostat_hc1_heat_temperature,number.thermostat_hc1_heattemp -FR110,thermostat,108,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp -FR110,thermostat,108,nofrosttemp,nofrost temperature,int (>=-63<=63),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp +FR110,thermostat,108,heattemp,heat temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_heat_temperature,number.thermostat_hc1_heattemp +FR110,thermostat,108,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp +FR110,thermostat,108,nofrosttemp,nofrost temperature,int8 (>=-63<=63),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp FR110,thermostat,108,control,control device,enum [off\|FB10\|FB100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control FR110,thermostat,108,program,program,enum [prog a\|prog b\|prog c\|prog d\|prog e\|prog f], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program -FR110,thermostat,108,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp -FR110,thermostat,108,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp -FR110,thermostat,108,summertemp,summer temperature,uint (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp +FR110,thermostat,108,remotetemp,room temperature from remote,int16 (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp +FR110,thermostat,108,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp +FR110,thermostat,108,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp FR110,thermostat,108,roomsensor,room sensor,enum [extern\|intern\|auto], ,true,select.thermostat_hc1_room_sensor,select.thermostat_hc1_roomsensor FR110,thermostat,108,holidaymode,holiday mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_holiday_mode,select.thermostat_hc1_holidaymode FR110,thermostat,108,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization FR110,thermostat,108,heatup,heatup,enum [slow\|medium\|fast], ,true,select.thermostat_hc1_heatup,select.thermostat_hc1_heatup -FR110,thermostat,108,minflowtemp,min flow temperature,uint (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp -FR110,thermostat,108,maxflowtemp,max flow temperature,uint (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp -FR110,thermostat,108,designtemp,design temperature,uint (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp +FR110,thermostat,108,minflowtemp,min flow temperature,uint8 (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp +FR110,thermostat,108,maxflowtemp,max flow temperature,uint8 (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp +FR110,thermostat,108,designtemp,design temperature,uint8 (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp FR110,thermostat,108,roominfluence,room influence,enum [off\|intern\|extern\|auto], ,true,select.thermostat_hc1_room_influence,select.thermostat_hc1_roominfluence -FR110,thermostat,108,roominflfactor,room influence factor,uint (>=0<=100),%,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor +FR110,thermostat,108,roominflfactor,room influence factor,uint8 (>=0<=100),%,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor FR110,thermostat,108,heatingtype,heating type,enum [off\|heatingcurve\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype FR110,thermostat,108,controlmode,control mode,enum [off\|unmixed\|unmixed IPM\|mixed IPM], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode +FR110,thermostat,108,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge FB10,thermostat,109,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode FB10,thermostat,109,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode FB10,thermostat,109,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime FB10,thermostat,109,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy -FB10,thermostat,109,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp -FB10,thermostat,109,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio -FB10,thermostat,109,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor -FB10,thermostat,109,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor -FB10,thermostat,109,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler -FB10,thermostat,109,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler -FB10,thermostat,109,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge -FB10,thermostat,109,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -FB10,thermostat,109,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +FB10,thermostat,109,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp +FB10,thermostat,109,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio +FB10,thermostat,109,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor +FB10,thermostat,109,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor +FB10,thermostat,109,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler +FB10,thermostat,109,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler +FB10,thermostat,109,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +FB10,thermostat,109,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp FB10,thermostat,109,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate FB10,thermostat,109,mode,mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode FB10,thermostat,109,modetype,mode type,enum [nofrost\|eco\|heat], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype -FB10,thermostat,109,heattemp,heat temperature,uint (>=0<=127),C,true,number.thermostat_hc1_heat_temperature,number.thermostat_hc1_heattemp -FB10,thermostat,109,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp -FB10,thermostat,109,nofrosttemp,nofrost temperature,int (>=-63<=63),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp +FB10,thermostat,109,heattemp,heat temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_heat_temperature,number.thermostat_hc1_heattemp +FB10,thermostat,109,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp +FB10,thermostat,109,nofrosttemp,nofrost temperature,int8 (>=-63<=63),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp FB10,thermostat,109,control,control device,enum [off\|FB10\|FB100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control FB10,thermostat,109,program,program,enum [prog a\|prog b\|prog c\|prog d\|prog e\|prog f], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program -FB10,thermostat,109,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp -FB10,thermostat,109,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp -FB10,thermostat,109,summertemp,summer temperature,uint (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp +FB10,thermostat,109,remotetemp,room temperature from remote,int16 (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp +FB10,thermostat,109,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp +FB10,thermostat,109,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp FB10,thermostat,109,roomsensor,room sensor,enum [extern\|intern\|auto], ,true,select.thermostat_hc1_room_sensor,select.thermostat_hc1_roomsensor FB10,thermostat,109,holidaymode,holiday mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_holiday_mode,select.thermostat_hc1_holidaymode FB10,thermostat,109,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization FB10,thermostat,109,heatup,heatup,enum [slow\|medium\|fast], ,true,select.thermostat_hc1_heatup,select.thermostat_hc1_heatup -FB10,thermostat,109,minflowtemp,min flow temperature,uint (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp -FB10,thermostat,109,maxflowtemp,max flow temperature,uint (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp -FB10,thermostat,109,designtemp,design temperature,uint (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp +FB10,thermostat,109,minflowtemp,min flow temperature,uint8 (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp +FB10,thermostat,109,maxflowtemp,max flow temperature,uint8 (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp +FB10,thermostat,109,designtemp,design temperature,uint8 (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp FB10,thermostat,109,roominfluence,room influence,enum [off\|intern\|extern\|auto], ,true,select.thermostat_hc1_room_influence,select.thermostat_hc1_roominfluence -FB10,thermostat,109,roominflfactor,room influence factor,uint (>=0<=100),%,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor +FB10,thermostat,109,roominflfactor,room influence factor,uint8 (>=0<=100),%,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor FB10,thermostat,109,heatingtype,heating type,enum [off\|heatingcurve\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype FB10,thermostat,109,controlmode,control mode,enum [off\|unmixed\|unmixed IPM\|mixed IPM], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode +FB10,thermostat,109,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge FB100,thermostat,110,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode FB100,thermostat,110,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode FB100,thermostat,110,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime FB100,thermostat,110,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy -FB100,thermostat,110,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp -FB100,thermostat,110,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio -FB100,thermostat,110,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor -FB100,thermostat,110,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor -FB100,thermostat,110,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler -FB100,thermostat,110,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler -FB100,thermostat,110,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge -FB100,thermostat,110,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -FB100,thermostat,110,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +FB100,thermostat,110,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp +FB100,thermostat,110,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio +FB100,thermostat,110,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor +FB100,thermostat,110,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor +FB100,thermostat,110,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler +FB100,thermostat,110,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler +FB100,thermostat,110,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +FB100,thermostat,110,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp FB100,thermostat,110,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate FB100,thermostat,110,mode,mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode FB100,thermostat,110,modetype,mode type,enum [nofrost\|eco\|heat], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype -FB100,thermostat,110,heattemp,heat temperature,uint (>=0<=127),C,true,number.thermostat_hc1_heat_temperature,number.thermostat_hc1_heattemp -FB100,thermostat,110,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp -FB100,thermostat,110,nofrosttemp,nofrost temperature,int (>=-63<=63),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp +FB100,thermostat,110,heattemp,heat temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_heat_temperature,number.thermostat_hc1_heattemp +FB100,thermostat,110,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp +FB100,thermostat,110,nofrosttemp,nofrost temperature,int8 (>=-63<=63),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp FB100,thermostat,110,control,control device,enum [off\|FB10\|FB100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control FB100,thermostat,110,program,program,enum [prog a\|prog b\|prog c\|prog d\|prog e\|prog f], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program -FB100,thermostat,110,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp -FB100,thermostat,110,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp -FB100,thermostat,110,summertemp,summer temperature,uint (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp +FB100,thermostat,110,remotetemp,room temperature from remote,int16 (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp +FB100,thermostat,110,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp +FB100,thermostat,110,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp FB100,thermostat,110,roomsensor,room sensor,enum [extern\|intern\|auto], ,true,select.thermostat_hc1_room_sensor,select.thermostat_hc1_roomsensor FB100,thermostat,110,holidaymode,holiday mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_holiday_mode,select.thermostat_hc1_holidaymode FB100,thermostat,110,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization FB100,thermostat,110,heatup,heatup,enum [slow\|medium\|fast], ,true,select.thermostat_hc1_heatup,select.thermostat_hc1_heatup -FB100,thermostat,110,minflowtemp,min flow temperature,uint (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp -FB100,thermostat,110,maxflowtemp,max flow temperature,uint (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp -FB100,thermostat,110,designtemp,design temperature,uint (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp +FB100,thermostat,110,minflowtemp,min flow temperature,uint8 (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp +FB100,thermostat,110,maxflowtemp,max flow temperature,uint8 (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp +FB100,thermostat,110,designtemp,design temperature,uint8 (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp FB100,thermostat,110,roominfluence,room influence,enum [off\|intern\|extern\|auto], ,true,select.thermostat_hc1_room_influence,select.thermostat_hc1_roominfluence -FB100,thermostat,110,roominflfactor,room influence factor,uint (>=0<=100),%,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor +FB100,thermostat,110,roominflfactor,room influence factor,uint8 (>=0<=100),%,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor FB100,thermostat,110,heatingtype,heating type,enum [off\|heatingcurve\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype FB100,thermostat,110,controlmode,control mode,enum [off\|unmixed\|unmixed IPM\|mixed IPM], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode +FB100,thermostat,110,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge FR10,thermostat,111,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode FR10,thermostat,111,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode FR10,thermostat,111,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime FR10,thermostat,111,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy -FR10,thermostat,111,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp -FR10,thermostat,111,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio -FR10,thermostat,111,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor -FR10,thermostat,111,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor -FR10,thermostat,111,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler -FR10,thermostat,111,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler -FR10,thermostat,111,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge -FR10,thermostat,111,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -FR10,thermostat,111,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +FR10,thermostat,111,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp +FR10,thermostat,111,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio +FR10,thermostat,111,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor +FR10,thermostat,111,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor +FR10,thermostat,111,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler +FR10,thermostat,111,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler +FR10,thermostat,111,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +FR10,thermostat,111,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp FR10,thermostat,111,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate FR10,thermostat,111,mode,mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode FR10,thermostat,111,modetype,mode type,enum [nofrost\|eco\|heat], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype -FR10,thermostat,111,heattemp,heat temperature,uint (>=0<=127),C,true,number.thermostat_hc1_heat_temperature,number.thermostat_hc1_heattemp -FR10,thermostat,111,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp -FR10,thermostat,111,nofrosttemp,nofrost temperature,int (>=-63<=63),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp +FR10,thermostat,111,heattemp,heat temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_heat_temperature,number.thermostat_hc1_heattemp +FR10,thermostat,111,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp +FR10,thermostat,111,nofrosttemp,nofrost temperature,int8 (>=-63<=63),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp FR10,thermostat,111,control,control device,enum [off\|FB10\|FB100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control FR10,thermostat,111,program,program,enum [prog a\|prog b\|prog c\|prog d\|prog e\|prog f], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program -FR10,thermostat,111,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp -FR10,thermostat,111,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp -FR10,thermostat,111,summertemp,summer temperature,uint (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp +FR10,thermostat,111,remotetemp,room temperature from remote,int16 (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp +FR10,thermostat,111,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp +FR10,thermostat,111,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp FR10,thermostat,111,roomsensor,room sensor,enum [extern\|intern\|auto], ,true,select.thermostat_hc1_room_sensor,select.thermostat_hc1_roomsensor FR10,thermostat,111,holidaymode,holiday mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_holiday_mode,select.thermostat_hc1_holidaymode FR10,thermostat,111,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization FR10,thermostat,111,heatup,heatup,enum [slow\|medium\|fast], ,true,select.thermostat_hc1_heatup,select.thermostat_hc1_heatup -FR10,thermostat,111,minflowtemp,min flow temperature,uint (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp -FR10,thermostat,111,maxflowtemp,max flow temperature,uint (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp -FR10,thermostat,111,designtemp,design temperature,uint (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp +FR10,thermostat,111,minflowtemp,min flow temperature,uint8 (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp +FR10,thermostat,111,maxflowtemp,max flow temperature,uint8 (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp +FR10,thermostat,111,designtemp,design temperature,uint8 (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp FR10,thermostat,111,roominfluence,room influence,enum [off\|intern\|extern\|auto], ,true,select.thermostat_hc1_room_influence,select.thermostat_hc1_roominfluence -FR10,thermostat,111,roominflfactor,room influence factor,uint (>=0<=100),%,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor +FR10,thermostat,111,roominflfactor,room influence factor,uint8 (>=0<=100),%,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor FR10,thermostat,111,heatingtype,heating type,enum [off\|heatingcurve\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype FR10,thermostat,111,controlmode,control mode,enum [off\|unmixed\|unmixed IPM\|mixed IPM], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode +FR10,thermostat,111,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge FW500,thermostat,116,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode FW500,thermostat,116,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode FW500,thermostat,116,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime FW500,thermostat,116,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy -FW500,thermostat,116,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp -FW500,thermostat,116,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio -FW500,thermostat,116,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor -FW500,thermostat,116,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor -FW500,thermostat,116,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler -FW500,thermostat,116,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler -FW500,thermostat,116,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge -FW500,thermostat,116,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -FW500,thermostat,116,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +FW500,thermostat,116,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp +FW500,thermostat,116,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio +FW500,thermostat,116,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor +FW500,thermostat,116,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor +FW500,thermostat,116,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler +FW500,thermostat,116,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler +FW500,thermostat,116,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +FW500,thermostat,116,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp FW500,thermostat,116,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate FW500,thermostat,116,mode,mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode FW500,thermostat,116,modetype,mode type,enum [nofrost\|eco\|heat], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype -FW500,thermostat,116,heattemp,heat temperature,uint (>=0<=127),C,true,number.thermostat_hc1_heat_temperature,number.thermostat_hc1_heattemp -FW500,thermostat,116,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp -FW500,thermostat,116,nofrosttemp,nofrost temperature,int (>=-63<=63),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp +FW500,thermostat,116,heattemp,heat temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_heat_temperature,number.thermostat_hc1_heattemp +FW500,thermostat,116,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp +FW500,thermostat,116,nofrosttemp,nofrost temperature,int8 (>=-63<=63),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp FW500,thermostat,116,control,control device,enum [off\|FB10\|FB100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control FW500,thermostat,116,program,program,enum [prog a\|prog b\|prog c\|prog d\|prog e\|prog f], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program -FW500,thermostat,116,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp -FW500,thermostat,116,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp -FW500,thermostat,116,summertemp,summer temperature,uint (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp +FW500,thermostat,116,remotetemp,room temperature from remote,int16 (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp +FW500,thermostat,116,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp +FW500,thermostat,116,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp FW500,thermostat,116,roomsensor,room sensor,enum [extern\|intern\|auto], ,true,select.thermostat_hc1_room_sensor,select.thermostat_hc1_roomsensor FW500,thermostat,116,holidaymode,holiday mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_holiday_mode,select.thermostat_hc1_holidaymode FW500,thermostat,116,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization FW500,thermostat,116,heatup,heatup,enum [slow\|medium\|fast], ,true,select.thermostat_hc1_heatup,select.thermostat_hc1_heatup -FW500,thermostat,116,minflowtemp,min flow temperature,uint (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp -FW500,thermostat,116,maxflowtemp,max flow temperature,uint (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp -FW500,thermostat,116,designtemp,design temperature,uint (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp +FW500,thermostat,116,minflowtemp,min flow temperature,uint8 (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp +FW500,thermostat,116,maxflowtemp,max flow temperature,uint8 (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp +FW500,thermostat,116,designtemp,design temperature,uint8 (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp FW500,thermostat,116,roominfluence,room influence,enum [off\|intern\|extern\|auto], ,true,select.thermostat_hc1_room_influence,select.thermostat_hc1_roominfluence -FW500,thermostat,116,roominflfactor,room influence factor,uint (>=0<=100),%,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor +FW500,thermostat,116,roominflfactor,room influence factor,uint8 (>=0<=100),%,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor FW500,thermostat,116,heatingtype,heating type,enum [off\|heatingcurve\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype FW500,thermostat,116,controlmode,control mode,enum [off\|unmixed\|unmixed IPM\|mixed IPM], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode +FW500,thermostat,116,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge FR50,thermostat,147,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode FR50,thermostat,147,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode FR50,thermostat,147,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime FR50,thermostat,147,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy -FR50,thermostat,147,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp -FR50,thermostat,147,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio -FR50,thermostat,147,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor -FR50,thermostat,147,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor -FR50,thermostat,147,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler -FR50,thermostat,147,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler -FR50,thermostat,147,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge -FR50,thermostat,147,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -FR50,thermostat,147,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +FR50,thermostat,147,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp +FR50,thermostat,147,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio +FR50,thermostat,147,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor +FR50,thermostat,147,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor +FR50,thermostat,147,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler +FR50,thermostat,147,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler +FR50,thermostat,147,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +FR50,thermostat,147,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp FR50,thermostat,147,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate FR50,thermostat,147,mode,mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode FR50,thermostat,147,modetype,mode type,enum [nofrost\|eco\|heat], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype -FR50,thermostat,147,heattemp,heat temperature,uint (>=0<=127),C,true,number.thermostat_hc1_heat_temperature,number.thermostat_hc1_heattemp -FR50,thermostat,147,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp -FR50,thermostat,147,nofrosttemp,nofrost temperature,int (>=-63<=63),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp +FR50,thermostat,147,heattemp,heat temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_heat_temperature,number.thermostat_hc1_heattemp +FR50,thermostat,147,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp +FR50,thermostat,147,nofrosttemp,nofrost temperature,int8 (>=-63<=63),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp FR50,thermostat,147,control,control device,enum [off\|FB10\|FB100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control FR50,thermostat,147,program,program,enum [prog a\|prog b\|prog c\|prog d\|prog e\|prog f], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program -FR50,thermostat,147,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp -FR50,thermostat,147,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp -FR50,thermostat,147,summertemp,summer temperature,uint (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp +FR50,thermostat,147,remotetemp,room temperature from remote,int16 (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp +FR50,thermostat,147,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp +FR50,thermostat,147,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp FR50,thermostat,147,roomsensor,room sensor,enum [extern\|intern\|auto], ,true,select.thermostat_hc1_room_sensor,select.thermostat_hc1_roomsensor FR50,thermostat,147,holidaymode,holiday mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_holiday_mode,select.thermostat_hc1_holidaymode FR50,thermostat,147,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization FR50,thermostat,147,heatup,heatup,enum [slow\|medium\|fast], ,true,select.thermostat_hc1_heatup,select.thermostat_hc1_heatup -FR50,thermostat,147,minflowtemp,min flow temperature,uint (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp -FR50,thermostat,147,maxflowtemp,max flow temperature,uint (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp -FR50,thermostat,147,designtemp,design temperature,uint (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp +FR50,thermostat,147,minflowtemp,min flow temperature,uint8 (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp +FR50,thermostat,147,maxflowtemp,max flow temperature,uint8 (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp +FR50,thermostat,147,designtemp,design temperature,uint8 (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp FR50,thermostat,147,roominfluence,room influence,enum [off\|intern\|extern\|auto], ,true,select.thermostat_hc1_room_influence,select.thermostat_hc1_roominfluence -FR50,thermostat,147,roominflfactor,room influence factor,uint (>=0<=100),%,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor +FR50,thermostat,147,roominflfactor,room influence factor,uint8 (>=0<=100),%,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor FR50,thermostat,147,heatingtype,heating type,enum [off\|heatingcurve\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype FR50,thermostat,147,controlmode,control mode,enum [off\|unmixed\|unmixed IPM\|mixed IPM], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode +FR50,thermostat,147,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge FR120,thermostat,191,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode FR120,thermostat,191,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode FR120,thermostat,191,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime FR120,thermostat,191,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy -FR120,thermostat,191,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp -FR120,thermostat,191,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio -FR120,thermostat,191,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor -FR120,thermostat,191,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor -FR120,thermostat,191,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler -FR120,thermostat,191,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler -FR120,thermostat,191,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge -FR120,thermostat,191,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -FR120,thermostat,191,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +FR120,thermostat,191,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp +FR120,thermostat,191,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio +FR120,thermostat,191,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor +FR120,thermostat,191,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor +FR120,thermostat,191,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler +FR120,thermostat,191,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler +FR120,thermostat,191,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +FR120,thermostat,191,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp FR120,thermostat,191,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate FR120,thermostat,191,mode,mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode FR120,thermostat,191,modetype,mode type,enum [nofrost\|eco\|heat], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype -FR120,thermostat,191,heattemp,heat temperature,uint (>=0<=127),C,true,number.thermostat_hc1_heat_temperature,number.thermostat_hc1_heattemp -FR120,thermostat,191,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp -FR120,thermostat,191,nofrosttemp,nofrost temperature,int (>=-63<=63),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp +FR120,thermostat,191,heattemp,heat temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_heat_temperature,number.thermostat_hc1_heattemp +FR120,thermostat,191,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp +FR120,thermostat,191,nofrosttemp,nofrost temperature,int8 (>=-63<=63),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp FR120,thermostat,191,control,control device,enum [off\|FB10\|FB100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control FR120,thermostat,191,program,program,enum [prog a\|prog b\|prog c\|prog d\|prog e\|prog f], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program -FR120,thermostat,191,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp -FR120,thermostat,191,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp -FR120,thermostat,191,summertemp,summer temperature,uint (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp +FR120,thermostat,191,remotetemp,room temperature from remote,int16 (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp +FR120,thermostat,191,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp +FR120,thermostat,191,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp FR120,thermostat,191,roomsensor,room sensor,enum [extern\|intern\|auto], ,true,select.thermostat_hc1_room_sensor,select.thermostat_hc1_roomsensor FR120,thermostat,191,holidaymode,holiday mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_holiday_mode,select.thermostat_hc1_holidaymode FR120,thermostat,191,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization FR120,thermostat,191,heatup,heatup,enum [slow\|medium\|fast], ,true,select.thermostat_hc1_heatup,select.thermostat_hc1_heatup -FR120,thermostat,191,minflowtemp,min flow temperature,uint (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp -FR120,thermostat,191,maxflowtemp,max flow temperature,uint (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp -FR120,thermostat,191,designtemp,design temperature,uint (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp +FR120,thermostat,191,minflowtemp,min flow temperature,uint8 (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp +FR120,thermostat,191,maxflowtemp,max flow temperature,uint8 (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp +FR120,thermostat,191,designtemp,design temperature,uint8 (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp FR120,thermostat,191,roominfluence,room influence,enum [off\|intern\|extern\|auto], ,true,select.thermostat_hc1_room_influence,select.thermostat_hc1_roominfluence -FR120,thermostat,191,roominflfactor,room influence factor,uint (>=0<=100),%,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor +FR120,thermostat,191,roominflfactor,room influence factor,uint8 (>=0<=100),%,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor FR120,thermostat,191,heatingtype,heating type,enum [off\|heatingcurve\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype FR120,thermostat,191,controlmode,control mode,enum [off\|unmixed\|unmixed IPM\|mixed IPM], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode +FR120,thermostat,191,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge FW120,thermostat,192,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode FW120,thermostat,192,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode FW120,thermostat,192,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime FW120,thermostat,192,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy -FW120,thermostat,192,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp -FW120,thermostat,192,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio -FW120,thermostat,192,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor -FW120,thermostat,192,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor -FW120,thermostat,192,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler -FW120,thermostat,192,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler -FW120,thermostat,192,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge -FW120,thermostat,192,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -FW120,thermostat,192,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +FW120,thermostat,192,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp +FW120,thermostat,192,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio +FW120,thermostat,192,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor +FW120,thermostat,192,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor +FW120,thermostat,192,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler +FW120,thermostat,192,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler +FW120,thermostat,192,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +FW120,thermostat,192,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp FW120,thermostat,192,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate FW120,thermostat,192,mode,mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode FW120,thermostat,192,modetype,mode type,enum [nofrost\|eco\|heat], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype -FW120,thermostat,192,heattemp,heat temperature,uint (>=0<=127),C,true,number.thermostat_hc1_heat_temperature,number.thermostat_hc1_heattemp -FW120,thermostat,192,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp -FW120,thermostat,192,nofrosttemp,nofrost temperature,int (>=-63<=63),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp +FW120,thermostat,192,heattemp,heat temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_heat_temperature,number.thermostat_hc1_heattemp +FW120,thermostat,192,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp +FW120,thermostat,192,nofrosttemp,nofrost temperature,int8 (>=-63<=63),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp FW120,thermostat,192,control,control device,enum [off\|FB10\|FB100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control FW120,thermostat,192,program,program,enum [prog a\|prog b\|prog c\|prog d\|prog e\|prog f], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program -FW120,thermostat,192,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp -FW120,thermostat,192,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp -FW120,thermostat,192,summertemp,summer temperature,uint (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp +FW120,thermostat,192,remotetemp,room temperature from remote,int16 (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp +FW120,thermostat,192,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp +FW120,thermostat,192,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp FW120,thermostat,192,roomsensor,room sensor,enum [extern\|intern\|auto], ,true,select.thermostat_hc1_room_sensor,select.thermostat_hc1_roomsensor FW120,thermostat,192,holidaymode,holiday mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_holiday_mode,select.thermostat_hc1_holidaymode FW120,thermostat,192,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization FW120,thermostat,192,heatup,heatup,enum [slow\|medium\|fast], ,true,select.thermostat_hc1_heatup,select.thermostat_hc1_heatup -FW120,thermostat,192,minflowtemp,min flow temperature,uint (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp -FW120,thermostat,192,maxflowtemp,max flow temperature,uint (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp -FW120,thermostat,192,designtemp,design temperature,uint (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp +FW120,thermostat,192,minflowtemp,min flow temperature,uint8 (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp +FW120,thermostat,192,maxflowtemp,max flow temperature,uint8 (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp +FW120,thermostat,192,designtemp,design temperature,uint8 (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp FW120,thermostat,192,roominfluence,room influence,enum [off\|intern\|extern\|auto], ,true,select.thermostat_hc1_room_influence,select.thermostat_hc1_roominfluence -FW120,thermostat,192,roominflfactor,room influence factor,uint (>=0<=100),%,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor +FW120,thermostat,192,roominflfactor,room influence factor,uint8 (>=0<=100),%,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor FW120,thermostat,192,heatingtype,heating type,enum [off\|heatingcurve\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype FW120,thermostat,192,controlmode,control mode,enum [off\|unmixed\|unmixed IPM\|mixed IPM], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode +FW120,thermostat,192,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge RT800,thermostat,3,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode RT800,thermostat,3,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode RT800,thermostat,3,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime -RT800,thermostat,3,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -RT800,thermostat,3,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +RT800,thermostat,3,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +RT800,thermostat,3,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp RT800,thermostat,3,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate RC100H,thermostat,200,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode RC100H,thermostat,200,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode RC100H,thermostat,200,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime -RC100H,thermostat,200,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -RC100H,thermostat,200,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +RC100H,thermostat,200,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +RC100H,thermostat,200,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp RC100H,thermostat,200,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate TR120RF/CR20RF,thermostat,249,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode TR120RF/CR20RF,thermostat,249,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode TR120RF/CR20RF,thermostat,249,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime -TR120RF/CR20RF,thermostat,249,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -TR120RF/CR20RF,thermostat,249,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +TR120RF/CR20RF,thermostat,249,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +TR120RF/CR20RF,thermostat,249,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp TR120RF/CR20RF,thermostat,249,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate -MM10,mixer,69,flowtemphc,flow temperature (TC1),ushort (>=0<=3199),C,false,sensor.mixer_hc1_flow_temperature_(TC1),sensor.mixer_hc1_flowtemphc -MM10,mixer,69,valvestatus,mixing valve actuator (VC1),int (>=-100<=100),%,false,sensor.mixer_hc1_mixing_valve_actuator_(VC1),sensor.mixer_hc1_valvestatus -MM10,mixer,69,flowsettemp,setpoint flow temperature,uint (>=0<=254),C,true,number.mixer_hc1_setpoint_flow_temperature,number.mixer_hc1_flowsettemp +MM10,mixer,69,flowtemphc,flow temperature (TC1),uint16 (>=0<=3199),C,false,sensor.mixer_hc1_flow_temperature_(TC1),sensor.mixer_hc1_flowtemphc +MM10,mixer,69,valvestatus,mixing valve actuator (VC1),int8 (>=-100<=100),%,false,sensor.mixer_hc1_mixing_valve_actuator_(VC1),sensor.mixer_hc1_valvestatus +MM10,mixer,69,flowsettemp,setpoint flow temperature,uint8 (>=0<=254),C,true,number.mixer_hc1_setpoint_flow_temperature,number.mixer_hc1_flowsettemp MM10,mixer,69,pumpstatus,pump status (PC1),boolean, ,true,switch.mixer_hc1_pump_status_(PC1),switch.mixer_hc1_pumpstatus MM10,mixer,69,activated,activated,boolean, ,true,switch.mixer_hc1_activated,switch.mixer_hc1_activated -MM10,mixer,69,valvesettime,time to set valve,uint (>=10<=120),seconds,true,number.mixer_hc1_time_to_set_valve,number.mixer_hc1_valvesettime -IPM,mixer,100,flowtemphc,flow temperature (TC1),ushort (>=0<=3199),C,false,sensor.mixer_hc1_flow_temperature_(TC1),sensor.mixer_hc1_flowtemphc -IPM,mixer,100,valvestatus,mixing valve actuator (VC1),uint (>=0<=100),%,false,sensor.mixer_hc1_mixing_valve_actuator_(VC1),sensor.mixer_hc1_valvestatus -IPM,mixer,100,flowsettemp,setpoint flow temperature,uint (>=0<=254),C,true,number.mixer_hc1_setpoint_flow_temperature,number.mixer_hc1_flowsettemp +MM10,mixer,69,valvesettime,time to set valve,uint8 (>=10<=120),seconds,true,number.mixer_hc1_time_to_set_valve,number.mixer_hc1_valvesettime +IPM,mixer,100,flowtemphc,flow temperature (TC1),uint16 (>=0<=3199),C,false,sensor.mixer_hc1_flow_temperature_(TC1),sensor.mixer_hc1_flowtemphc +IPM,mixer,100,valvestatus,mixing valve actuator (VC1),uint8 (>=0<=100),%,false,sensor.mixer_hc1_mixing_valve_actuator_(VC1),sensor.mixer_hc1_valvestatus +IPM,mixer,100,flowsettemp,setpoint flow temperature,uint8 (>=0<=254),C,true,number.mixer_hc1_setpoint_flow_temperature,number.mixer_hc1_flowsettemp IPM,mixer,100,pumpstatus,pump status (PC1),boolean, ,true,switch.mixer_hc1_pump_status_(PC1),switch.mixer_hc1_pumpstatus -IPM,mixer,100,flowtempvf,flow temperature in header (T0/Vf),ushort (>=0<=3199),C,false,sensor.mixer_hc1_flow_temperature_in_header_(T0/Vf),sensor.mixer_hc1_flowtempvf -IPM,mixer,102,flowtemphc,flow temperature (TC1),ushort (>=0<=3199),C,false,sensor.mixer_hc1_flow_temperature_(TC1),sensor.mixer_hc1_flowtemphc -IPM,mixer,102,valvestatus,mixing valve actuator (VC1),uint (>=0<=100),%,false,sensor.mixer_hc1_mixing_valve_actuator_(VC1),sensor.mixer_hc1_valvestatus -IPM,mixer,102,flowsettemp,setpoint flow temperature,uint (>=0<=254),C,true,number.mixer_hc1_setpoint_flow_temperature,number.mixer_hc1_flowsettemp +IPM,mixer,100,flowtempvf,flow temperature in header (T0/Vf),uint16 (>=0<=3199),C,false,sensor.mixer_hc1_flow_temperature_in_header_(T0/Vf),sensor.mixer_hc1_flowtempvf +IPM,mixer,102,flowtemphc,flow temperature (TC1),uint16 (>=0<=3199),C,false,sensor.mixer_hc1_flow_temperature_(TC1),sensor.mixer_hc1_flowtemphc +IPM,mixer,102,valvestatus,mixing valve actuator (VC1),uint8 (>=0<=100),%,false,sensor.mixer_hc1_mixing_valve_actuator_(VC1),sensor.mixer_hc1_valvestatus +IPM,mixer,102,flowsettemp,setpoint flow temperature,uint8 (>=0<=254),C,true,number.mixer_hc1_setpoint_flow_temperature,number.mixer_hc1_flowsettemp IPM,mixer,102,pumpstatus,pump status (PC1),boolean, ,true,switch.mixer_hc1_pump_status_(PC1),switch.mixer_hc1_pumpstatus -IPM,mixer,102,flowtempvf,flow temperature in header (T0/Vf),ushort (>=0<=3199),C,false,sensor.mixer_hc1_flow_temperature_in_header_(T0/Vf),sensor.mixer_hc1_flowtempvf -MM50,mixer,159,flowtemphc,flow temperature (TC1),ushort (>=0<=3199),C,false,sensor.mixer_hc1_flow_temperature_(TC1),sensor.mixer_hc1_flowtemphc -MM50,mixer,159,valvestatus,mixing valve actuator (VC1),uint (>=0<=100),%,false,sensor.mixer_hc1_mixing_valve_actuator_(VC1),sensor.mixer_hc1_valvestatus -MM50,mixer,159,flowsettemp,setpoint flow temperature,uint (>=0<=254),C,true,number.mixer_hc1_setpoint_flow_temperature,number.mixer_hc1_flowsettemp +IPM,mixer,102,flowtempvf,flow temperature in header (T0/Vf),uint16 (>=0<=3199),C,false,sensor.mixer_hc1_flow_temperature_in_header_(T0/Vf),sensor.mixer_hc1_flowtempvf +MM50,mixer,159,flowtemphc,flow temperature (TC1),uint16 (>=0<=3199),C,false,sensor.mixer_hc1_flow_temperature_(TC1),sensor.mixer_hc1_flowtemphc +MM50,mixer,159,valvestatus,mixing valve actuator (VC1),uint8 (>=0<=100),%,false,sensor.mixer_hc1_mixing_valve_actuator_(VC1),sensor.mixer_hc1_valvestatus +MM50,mixer,159,flowsettemp,setpoint flow temperature,uint8 (>=0<=254),C,true,number.mixer_hc1_setpoint_flow_temperature,number.mixer_hc1_flowsettemp MM50,mixer,159,pumpstatus,pump status (PC1),boolean, ,true,switch.mixer_hc1_pump_status_(PC1),switch.mixer_hc1_pumpstatus MM50,mixer,159,activated,activated,boolean, ,true,switch.mixer_hc1_activated,switch.mixer_hc1_activated -MM50,mixer,159,valvesettime,time to set valve,uint (>=10<=600),seconds,true,number.mixer_hc1_time_to_set_valve,number.mixer_hc1_valvesettime -MM50,mixer,159,flowtempoffset,flow temperature offset for mixer,uint (>=0<=20),K,true,number.mixer_hc1_flow_temperature_offset_for_mixer,number.mixer_hc1_flowtempoffset -MM100,mixer,160,flowtemphc,flow temperature (TC1),ushort (>=0<=3199),C,false,sensor.mixer_wwc1_flow_temperature_(TC1),sensor.mixer_wwc1_flowtemphc -MM100,mixer,160,valvestatus,mixing valve actuator (VC1),uint (>=0<=100),%,false,sensor.mixer_wwc1_mixing_valve_actuator_(VC1),sensor.mixer_wwc1_valvestatus -MM100,mixer,160,flowsettemp,setpoint flow temperature,uint (>=0<=254),C,true,number.mixer_wwc1_setpoint_flow_temperature,number.mixer_wwc1_flowsettemp -MM100,mixer,160,pumpstatus,pump status (PC1),boolean, ,true,switch.mixer_wwc1_pump_status_(PC1),switch.mixer_wwc1_pumpstatus -MM100,mixer,160,activated,activated,boolean, ,true,switch.mixer_wwc1_activated,switch.mixer_wwc1_activated -MM100,mixer,160,valvesettime,time to set valve,uint (>=10<=600),seconds,true,number.mixer_wwc1_time_to_set_valve,number.mixer_wwc1_valvesettime -MM100,mixer,160,flowtempoffset,flow temperature offset for mixer,uint (>=0<=20),K,true,number.mixer_wwc1_flow_temperature_offset_for_mixer,number.mixer_wwc1_flowtempoffset -MM200,mixer,161,flowtemphc,flow temperature (TC1),ushort (>=0<=3199),C,false,sensor.mixer_hc1_flow_temperature_(TC1),sensor.mixer_hc1_flowtemphc -MM200,mixer,161,valvestatus,mixing valve actuator (VC1),uint (>=0<=100),%,false,sensor.mixer_hc1_mixing_valve_actuator_(VC1),sensor.mixer_hc1_valvestatus -MM200,mixer,161,flowsettemp,setpoint flow temperature,uint (>=0<=254),C,true,number.mixer_hc1_setpoint_flow_temperature,number.mixer_hc1_flowsettemp +MM50,mixer,159,valvesettime,time to set valve,uint8 (>=10<=600),seconds,true,number.mixer_hc1_time_to_set_valve,number.mixer_hc1_valvesettime +MM50,mixer,159,flowtempoffset,flow temperature offset for mixer,uint8 (>=0<=20),K,true,number.mixer_hc1_flow_temperature_offset_for_mixer,number.mixer_hc1_flowtempoffset +MM100,mixer,160,flowtemphc,flow temperature (TC1),uint16 (>=0<=3199),C,false,sensor.mixer_dhw_flow_temperature_(TC1),sensor.mixer_dhw_flowtemphc +MM100,mixer,160,valvestatus,mixing valve actuator (VC1),uint8 (>=0<=100),%,false,sensor.mixer_dhw_mixing_valve_actuator_(VC1),sensor.mixer_dhw_valvestatus +MM100,mixer,160,flowsettemp,setpoint flow temperature,uint8 (>=0<=254),C,true,number.mixer_dhw_setpoint_flow_temperature,number.mixer_dhw_flowsettemp +MM100,mixer,160,pumpstatus,pump status (PC1),boolean, ,true,switch.mixer_dhw_pump_status_(PC1),switch.mixer_dhw_pumpstatus +MM100,mixer,160,activated,activated,boolean, ,true,switch.mixer_dhw_activated,switch.mixer_dhw_activated +MM100,mixer,160,valvesettime,time to set valve,uint8 (>=10<=600),seconds,true,number.mixer_dhw_time_to_set_valve,number.mixer_dhw_valvesettime +MM100,mixer,160,flowtempoffset,flow temperature offset for mixer,uint8 (>=0<=20),K,true,number.mixer_dhw_flow_temperature_offset_for_mixer,number.mixer_dhw_flowtempoffset +MM200,mixer,161,flowtemphc,flow temperature (TC1),uint16 (>=0<=3199),C,false,sensor.mixer_hc1_flow_temperature_(TC1),sensor.mixer_hc1_flowtemphc +MM200,mixer,161,valvestatus,mixing valve actuator (VC1),uint8 (>=0<=100),%,false,sensor.mixer_hc1_mixing_valve_actuator_(VC1),sensor.mixer_hc1_valvestatus +MM200,mixer,161,flowsettemp,setpoint flow temperature,uint8 (>=0<=254),C,true,number.mixer_hc1_setpoint_flow_temperature,number.mixer_hc1_flowsettemp MM200,mixer,161,pumpstatus,pump status (PC1),boolean, ,true,switch.mixer_hc1_pump_status_(PC1),switch.mixer_hc1_pumpstatus MM200,mixer,161,activated,activated,boolean, ,true,switch.mixer_hc1_activated,switch.mixer_hc1_activated -MM200,mixer,161,valvesettime,time to set valve,uint (>=10<=600),seconds,true,number.mixer_hc1_time_to_set_valve,number.mixer_hc1_valvesettime -MM200,mixer,161,flowtempoffset,flow temperature offset for mixer,uint (>=0<=20),K,true,number.mixer_hc1_flow_temperature_offset_for_mixer,number.mixer_hc1_flowtempoffset -MZ100,mixer,193,flowtemphc,flow temperature (TC1),ushort (>=0<=3199),C,false,sensor.mixer_hc1_flow_temperature_(TC1),sensor.mixer_hc1_flowtemphc -MZ100,mixer,193,valvestatus,mixing valve actuator (VC1),uint (>=0<=100),%,false,sensor.mixer_hc1_mixing_valve_actuator_(VC1),sensor.mixer_hc1_valvestatus -MZ100,mixer,193,flowsettemp,setpoint flow temperature,uint (>=0<=254),C,true,number.mixer_hc1_setpoint_flow_temperature,number.mixer_hc1_flowsettemp +MM200,mixer,161,valvesettime,time to set valve,uint8 (>=10<=600),seconds,true,number.mixer_hc1_time_to_set_valve,number.mixer_hc1_valvesettime +MM200,mixer,161,flowtempoffset,flow temperature offset for mixer,uint8 (>=0<=20),K,true,number.mixer_hc1_flow_temperature_offset_for_mixer,number.mixer_hc1_flowtempoffset +MZ100,mixer,193,flowtemphc,flow temperature (TC1),uint16 (>=0<=3199),C,false,sensor.mixer_hc1_flow_temperature_(TC1),sensor.mixer_hc1_flowtemphc +MZ100,mixer,193,valvestatus,mixing valve actuator (VC1),uint8 (>=0<=100),%,false,sensor.mixer_hc1_mixing_valve_actuator_(VC1),sensor.mixer_hc1_valvestatus +MZ100,mixer,193,flowsettemp,setpoint flow temperature,uint8 (>=0<=254),C,true,number.mixer_hc1_setpoint_flow_temperature,number.mixer_hc1_flowsettemp MZ100,mixer,193,pumpstatus,pump status (PC1),boolean, ,true,switch.mixer_hc1_pump_status_(PC1),switch.mixer_hc1_pumpstatus MZ100,mixer,193,activated,activated,boolean, ,true,switch.mixer_hc1_activated,switch.mixer_hc1_activated -MZ100,mixer,193,valvesettime,time to set valve,uint (>=10<=600),seconds,true,number.mixer_hc1_time_to_set_valve,number.mixer_hc1_valvesettime -MZ100,mixer,193,flowtempoffset,flow temperature offset for mixer,uint (>=0<=20),K,true,number.mixer_hc1_flow_temperature_offset_for_mixer,number.mixer_hc1_flowtempoffset -SM10,solar,73,collectortemp,collector temperature (TS1),short (>=-3199<=3199),C,false,sensor.solar_collector_temperature_(TS1),sensor.solar_collectortemp -SM10,solar,73,cylbottomtemp,cylinder bottom temperature (TS2),short (>=-3199<=3199),C,false,sensor.solar_cylinder_bottom_temperature_(TS2),sensor.solar_cylbottomtemp +MZ100,mixer,193,valvesettime,time to set valve,uint8 (>=10<=600),seconds,true,number.mixer_hc1_time_to_set_valve,number.mixer_hc1_valvesettime +MZ100,mixer,193,flowtempoffset,flow temperature offset for mixer,uint8 (>=0<=20),K,true,number.mixer_hc1_flow_temperature_offset_for_mixer,number.mixer_hc1_flowtempoffset +SM10,solar,73,collectortemp,collector temperature (TS1),int16 (>=-3199<=3199),C,false,sensor.solar_collector_temperature_(TS1),sensor.solar_collectortemp +SM10,solar,73,cylbottomtemp,cylinder bottom temperature (TS2),int16 (>=-3199<=3199),C,false,sensor.solar_cylinder_bottom_temperature_(TS2),sensor.solar_cylbottomtemp SM10,solar,73,solarpump,pump (PS1),boolean, ,false,binary_sensor.solar_pump_(PS1),binary_sensor.solar_solarpump SM10,solar,73,pumpworktime,pump working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_working_time,sensor.solar_pumpworktime -SM10,solar,73,cylmaxtemp,maximum cylinder temperature,uint (>=0<=254),C,true,number.solar_maximum_cylinder_temperature,number.solar_cylmaxtemp +SM10,solar,73,cylmaxtemp,maximum cylinder temperature,uint8 (>=0<=254),C,true,number.solar_maximum_cylinder_temperature,number.solar_cylmaxtemp SM10,solar,73,collectorshutdown,collector shutdown,boolean, ,false,binary_sensor.solar_collector_shutdown,binary_sensor.solar_collectorshutdown SM10,solar,73,cylheated,cyl heated,boolean, ,false,binary_sensor.solar_cyl_heated,binary_sensor.solar_cylheated -SM10,solar,73,solarpumpmod,pump modulation (PS1),uint (>=0<=100),%,false,sensor.solar_pump_modulation_(PS1),sensor.solar_solarpumpmod -SM10,solar,73,pumpminmod,minimum pump modulation,uint (>=0<=100),%,true,number.solar_minimum_pump_modulation,number.solar_pumpminmod -SM10,solar,73,turnondiff,pump turn on difference,uint (>=0<=254),C,true,number.solar_pump_turn_on_difference,number.solar_turnondiff -SM10,solar,73,turnoffdiff,pump turn off difference,uint (>=0<=254),C,true,number.solar_pump_turn_off_difference,number.solar_turnoffdiff -SM10,solar,73,solarpower,actual solar power,short (>=-31999<=31999),W,false,sensor.solar_actual_solar_power,sensor.solar_solarpower -SM10,solar,73,energylasthour,energy last hour,ulong (>=0<=1677721),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour -SM10,solar,73,maxflow,maximum solar flow,uint (>=0<=25),l/min,true,number.solar_maximum_solar_flow,number.solar_maxflow -SM10,solar,73,wwmintemp,minimum temperature,uint (>=0<=254),C,true,number.solar_minimum_temperature,number.solar_wwmintemp +SM10,solar,73,solarpumpmod,pump modulation (PS1),uint8 (>=0<=100),%,false,sensor.solar_pump_modulation_(PS1),sensor.solar_solarpumpmod +SM10,solar,73,pumpminmod,minimum pump modulation,uint8 (>=0<=100),%,true,number.solar_minimum_pump_modulation,number.solar_pumpminmod +SM10,solar,73,turnondiff,pump turn on difference,uint8 (>=0<=254),C,true,number.solar_pump_turn_on_difference,number.solar_turnondiff +SM10,solar,73,turnoffdiff,pump turn off difference,uint8 (>=0<=254),C,true,number.solar_pump_turn_off_difference,number.solar_turnoffdiff +SM10,solar,73,solarpower,actual solar power,int16 (>=-31999<=31999),W,false,sensor.solar_actual_solar_power,sensor.solar_solarpower +SM10,solar,73,energylasthour,energy last hour,uint24 (>=0<=1677721),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour +SM10,solar,73,maxflow,maximum solar flow,uint8 (>=0<=25),l/min,true,number.solar_maximum_solar_flow,number.solar_maxflow +SM10,solar,73,mintemp,minimum temperature,uint8 (>=0<=254),C,true,number.solar_dhw_minimum_temperature,number.solar_dhw_mintemp SM10,solar,73,solarenabled,solarmodule enabled,boolean, ,true,switch.solar_solarmodule_enabled,switch.solar_solarenabled -ISM1,solar,101,collectortemp,collector temperature (TS1),short (>=-3199<=3199),C,false,sensor.solar_collector_temperature_(TS1),sensor.solar_collectortemp -ISM1,solar,101,cylbottomtemp,cylinder bottom temperature (TS2),short (>=-3199<=3199),C,false,sensor.solar_cylinder_bottom_temperature_(TS2),sensor.solar_cylbottomtemp +ISM1,solar,101,collectortemp,collector temperature (TS1),int16 (>=-3199<=3199),C,false,sensor.solar_collector_temperature_(TS1),sensor.solar_collectortemp +ISM1,solar,101,cylbottomtemp,cylinder bottom temperature (TS2),int16 (>=-3199<=3199),C,false,sensor.solar_cylinder_bottom_temperature_(TS2),sensor.solar_cylbottomtemp ISM1,solar,101,solarpump,pump (PS1),boolean, ,false,binary_sensor.solar_pump_(PS1),binary_sensor.solar_solarpump ISM1,solar,101,pumpworktime,pump working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_working_time,sensor.solar_pumpworktime -ISM1,solar,101,cylmaxtemp,maximum cylinder temperature,uint (>=0<=254),C,true,number.solar_maximum_cylinder_temperature,number.solar_cylmaxtemp +ISM1,solar,101,cylmaxtemp,maximum cylinder temperature,uint8 (>=0<=254),C,true,number.solar_maximum_cylinder_temperature,number.solar_cylmaxtemp ISM1,solar,101,collectorshutdown,collector shutdown,boolean, ,false,binary_sensor.solar_collector_shutdown,binary_sensor.solar_collectorshutdown ISM1,solar,101,cylheated,cyl heated,boolean, ,false,binary_sensor.solar_cyl_heated,binary_sensor.solar_cylheated -ISM1,solar,101,cylmiddletemp,cylinder middle temperature (TS3),short (>=-3199<=3199),C,false,sensor.solar_cylinder_middle_temperature_(TS3),sensor.solar_cylmiddletemp -ISM1,solar,101,retheatassist,return temperature heat assistance (TS4),short (>=-3199<=3199),C,false,sensor.solar_return_temperature_heat_assistance_(TS4),sensor.solar_retheatassist +ISM1,solar,101,cylmiddletemp,cylinder middle temperature (TS3),int16 (>=-3199<=3199),C,false,sensor.solar_cylinder_middle_temperature_(TS3),sensor.solar_cylmiddletemp +ISM1,solar,101,retheatassist,return temperature heat assistance (TS4),int16 (>=-3199<=3199),C,false,sensor.solar_return_temperature_heat_assistance_(TS4),sensor.solar_retheatassist ISM1,solar,101,heatassistvalve,heat assistance valve (M1),boolean, ,false,binary_sensor.solar_heat_assistance_valve_(M1),binary_sensor.solar_heatassistvalve -ISM1,solar,101,energylasthour,energy last hour,ulong (>=0<=1677721),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour -ISM2,solar,103,collectortemp,collector temperature (TS1),short (>=-3199<=3199),C,false,sensor.solar_collector_temperature_(TS1),sensor.solar_collectortemp -ISM2,solar,103,cylbottomtemp,cylinder bottom temperature (TS2),short (>=-3199<=3199),C,false,sensor.solar_cylinder_bottom_temperature_(TS2),sensor.solar_cylbottomtemp +ISM1,solar,101,energylasthour,energy last hour,uint24 (>=0<=1677721),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour +ISM2,solar,103,collectortemp,collector temperature (TS1),int16 (>=-3199<=3199),C,false,sensor.solar_collector_temperature_(TS1),sensor.solar_collectortemp +ISM2,solar,103,cylbottomtemp,cylinder bottom temperature (TS2),int16 (>=-3199<=3199),C,false,sensor.solar_cylinder_bottom_temperature_(TS2),sensor.solar_cylbottomtemp ISM2,solar,103,solarpump,pump (PS1),boolean, ,false,binary_sensor.solar_pump_(PS1),binary_sensor.solar_solarpump ISM2,solar,103,pumpworktime,pump working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_working_time,sensor.solar_pumpworktime -ISM2,solar,103,cylmaxtemp,maximum cylinder temperature,uint (>=0<=254),C,true,number.solar_maximum_cylinder_temperature,number.solar_cylmaxtemp +ISM2,solar,103,cylmaxtemp,maximum cylinder temperature,uint8 (>=0<=254),C,true,number.solar_maximum_cylinder_temperature,number.solar_cylmaxtemp ISM2,solar,103,collectorshutdown,collector shutdown,boolean, ,false,binary_sensor.solar_collector_shutdown,binary_sensor.solar_collectorshutdown ISM2,solar,103,cylheated,cyl heated,boolean, ,false,binary_sensor.solar_cyl_heated,binary_sensor.solar_cylheated -ISM2,solar,103,cylmiddletemp,cylinder middle temperature (TS3),short (>=-3199<=3199),C,false,sensor.solar_cylinder_middle_temperature_(TS3),sensor.solar_cylmiddletemp -ISM2,solar,103,retheatassist,return temperature heat assistance (TS4),short (>=-3199<=3199),C,false,sensor.solar_return_temperature_heat_assistance_(TS4),sensor.solar_retheatassist +ISM2,solar,103,cylmiddletemp,cylinder middle temperature (TS3),int16 (>=-3199<=3199),C,false,sensor.solar_cylinder_middle_temperature_(TS3),sensor.solar_cylmiddletemp +ISM2,solar,103,retheatassist,return temperature heat assistance (TS4),int16 (>=-3199<=3199),C,false,sensor.solar_return_temperature_heat_assistance_(TS4),sensor.solar_retheatassist ISM2,solar,103,heatassistvalve,heat assistance valve (M1),boolean, ,false,binary_sensor.solar_heat_assistance_valve_(M1),binary_sensor.solar_heatassistvalve -ISM2,solar,103,energylasthour,energy last hour,ulong (>=0<=1677721),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour -SM50,solar,162,collectortemp,collector temperature (TS1),short (>=-3199<=3199),C,false,sensor.solar_collector_temperature_(TS1),sensor.solar_collectortemp -SM50,solar,162,cylbottomtemp,cylinder bottom temperature (TS2),short (>=-3199<=3199),C,false,sensor.solar_cylinder_bottom_temperature_(TS2),sensor.solar_cylbottomtemp +ISM2,solar,103,energylasthour,energy last hour,uint24 (>=0<=1677721),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour +SM50,solar,162,collectortemp,collector temperature (TS1),int16 (>=-3199<=3199),C,false,sensor.solar_collector_temperature_(TS1),sensor.solar_collectortemp +SM50,solar,162,cylbottomtemp,cylinder bottom temperature (TS2),int16 (>=-3199<=3199),C,false,sensor.solar_cylinder_bottom_temperature_(TS2),sensor.solar_cylbottomtemp SM50,solar,162,solarpump,pump (PS1),boolean, ,false,binary_sensor.solar_pump_(PS1),binary_sensor.solar_solarpump SM50,solar,162,pumpworktime,pump working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_working_time,sensor.solar_pumpworktime -SM50,solar,162,cylmaxtemp,maximum cylinder temperature,uint (>=0<=254),C,true,number.solar_maximum_cylinder_temperature,number.solar_cylmaxtemp +SM50,solar,162,cylmaxtemp,maximum cylinder temperature,uint8 (>=0<=254),C,true,number.solar_maximum_cylinder_temperature,number.solar_cylmaxtemp SM50,solar,162,collectorshutdown,collector shutdown,boolean, ,false,binary_sensor.solar_collector_shutdown,binary_sensor.solar_collectorshutdown SM50,solar,162,cylheated,cyl heated,boolean, ,false,binary_sensor.solar_cyl_heated,binary_sensor.solar_cylheated -SM50,solar,162,solarpumpmod,pump modulation (PS1),uint (>=0<=100),%,false,sensor.solar_pump_modulation_(PS1),sensor.solar_solarpumpmod -SM50,solar,162,pumpminmod,minimum pump modulation,uint (>=0<=100),%,true,number.solar_minimum_pump_modulation,number.solar_pumpminmod -SM50,solar,162,turnondiff,pump turn on difference,uint (>=0<=25),C,true,number.solar_pump_turn_on_difference,number.solar_turnondiff -SM50,solar,162,turnoffdiff,pump turn off difference,uint (>=0<=25),C,true,number.solar_pump_turn_off_difference,number.solar_turnoffdiff -SM50,solar,162,collector2temp,collector 2 temperature (TS7),short (>=-3199<=3199),C,false,sensor.solar_collector_2_temperature_(TS7),sensor.solar_collector2temp -SM50,solar,162,cylmiddletemp,cylinder middle temperature (TS3),short (>=-3199<=3199),C,false,sensor.solar_cylinder_middle_temperature_(TS3),sensor.solar_cylmiddletemp -SM50,solar,162,retheatassist,return temperature heat assistance (TS4),short (>=-3199<=3199),C,false,sensor.solar_return_temperature_heat_assistance_(TS4),sensor.solar_retheatassist +SM50,solar,162,solarpumpmod,pump modulation (PS1),uint8 (>=0<=100),%,false,sensor.solar_pump_modulation_(PS1),sensor.solar_solarpumpmod +SM50,solar,162,pumpminmod,minimum pump modulation,uint8 (>=0<=100),%,true,number.solar_minimum_pump_modulation,number.solar_pumpminmod +SM50,solar,162,turnondiff,pump turn on difference,uint8 (>=0<=25),C,true,number.solar_pump_turn_on_difference,number.solar_turnondiff +SM50,solar,162,turnoffdiff,pump turn off difference,uint8 (>=0<=25),C,true,number.solar_pump_turn_off_difference,number.solar_turnoffdiff +SM50,solar,162,collector2temp,collector 2 temperature (TS7),int16 (>=-3199<=3199),C,false,sensor.solar_collector_2_temperature_(TS7),sensor.solar_collector2temp +SM50,solar,162,cylmiddletemp,cylinder middle temperature (TS3),int16 (>=-3199<=3199),C,false,sensor.solar_cylinder_middle_temperature_(TS3),sensor.solar_cylmiddletemp +SM50,solar,162,retheatassist,return temperature heat assistance (TS4),int16 (>=-3199<=3199),C,false,sensor.solar_return_temperature_heat_assistance_(TS4),sensor.solar_retheatassist SM50,solar,162,heatassistvalve,heat assistance valve (M1),boolean, ,false,binary_sensor.solar_heat_assistance_valve_(M1),binary_sensor.solar_heatassistvalve -SM50,solar,162,heatassistpower,heat assistance valve power (M1),uint (>=0<=100),%,false,sensor.solar_heat_assistance_valve_power_(M1),sensor.solar_heatassistpower +SM50,solar,162,heatassistpower,heat assistance valve power (M1),uint8 (>=0<=100),%,false,sensor.solar_heat_assistance_valve_power_(M1),sensor.solar_heatassistpower SM50,solar,162,solarpump2,pump 2 (PS4),boolean, ,false,binary_sensor.solar_pump_2_(PS4),binary_sensor.solar_solarpump2 -SM50,solar,162,solarpump2mod,pump 2 modulation (PS4),uint (>=0<=100),%,false,sensor.solar_pump_2_modulation_(PS4),sensor.solar_solarpump2mod -SM50,solar,162,cyl2bottomtemp,second cylinder bottom temperature (TS5),short (>=-3199<=3199),C,false,sensor.solar_second_cylinder_bottom_temperature_(TS5),sensor.solar_cyl2bottomtemp -SM50,solar,162,heatexchangertemp,heat exchanger temperature (TS6),short (>=-3199<=3199),C,false,sensor.solar_heat_exchanger_temperature_(TS6),sensor.solar_heatexchangertemp -SM50,solar,162,cylpumpmod,cylinder pump modulation (PS5),uint (>=0<=100),%,false,sensor.solar_cylinder_pump_modulation_(PS5),sensor.solar_cylpumpmod +SM50,solar,162,solarpump2mod,pump 2 modulation (PS4),uint8 (>=0<=100),%,false,sensor.solar_pump_2_modulation_(PS4),sensor.solar_solarpump2mod +SM50,solar,162,cyl2bottomtemp,second cylinder bottom temperature (TS5),int16 (>=-3199<=3199),C,false,sensor.solar_second_cylinder_bottom_temperature_(TS5),sensor.solar_cyl2bottomtemp +SM50,solar,162,heatexchangertemp,heat exchanger temperature (TS6),int16 (>=-3199<=3199),C,false,sensor.solar_heat_exchanger_temperature_(TS6),sensor.solar_heatexchangertemp +SM50,solar,162,cylpumpmod,cylinder pump modulation (PS5),uint8 (>=0<=100),%,false,sensor.solar_cylinder_pump_modulation_(PS5),sensor.solar_cylpumpmod SM50,solar,162,valvestatus,valve status,boolean, ,false,binary_sensor.solar_valve_status,binary_sensor.solar_valvestatus SM50,solar,162,vs1status,valve status VS1,boolean, ,false,binary_sensor.solar_valve_status_VS1,binary_sensor.solar_vs1status -SM50,solar,162,collectormaxtemp,maximum collector temperature,uint (>=0<=254),C,true,number.solar_maximum_collector_temperature,number.solar_collectormaxtemp -SM50,solar,162,collectormintemp,minimum collector temperature,uint (>=0<=254),C,true,number.solar_minimum_collector_temperature,number.solar_collectormintemp -SM50,solar,162,energylasthour,energy last hour,ulong (>=0<=1677721),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour -SM50,solar,162,energytoday,total energy today,ulong (>=0<=16777213),Wh,false,sensor.solar_total_energy_today,sensor.solar_energytoday -SM50,solar,162,energytotal,total energy,ulong (>=0<=1677721),kWh,false,sensor.solar_total_energy,sensor.solar_energytotal +SM50,solar,162,collectormaxtemp,maximum collector temperature,uint8 (>=0<=254),C,true,number.solar_maximum_collector_temperature,number.solar_collectormaxtemp +SM50,solar,162,collectormintemp,minimum collector temperature,uint8 (>=0<=254),C,true,number.solar_minimum_collector_temperature,number.solar_collectormintemp +SM50,solar,162,energylasthour,energy last hour,uint24 (>=0<=1677721),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour +SM50,solar,162,energytoday,total energy today,uint24 (>=0<=16777213),Wh,false,sensor.solar_total_energy_today,sensor.solar_energytoday +SM50,solar,162,energytotal,total energy,uint24 (>=0<=1677721),kWh,false,sensor.solar_total_energy,sensor.solar_energytotal SM50,solar,162,pump2worktime,pump 2 working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_2_working_time,sensor.solar_pump2worktime SM50,solar,162,m1worktime,differential control working time,time (>=0<=16777213),minutes,false,sensor.solar_differential_control_working_time,sensor.solar_m1worktime SM50,solar,162,heattransfersystem,heattransfer system,boolean, ,true,switch.solar_heattransfer_system,switch.solar_heattransfersystem @@ -4730,49 +4826,49 @@ SM50,solar,162,solarpumpmode,pump mode,enum [constant\|pwm\|analog], ,true,selec SM50,solar,162,pumpkick,pump kick,boolean, ,true,switch.solar_pump_kick,switch.solar_pumpkick SM50,solar,162,plainwatermode,plain water mode,boolean, ,true,switch.solar_plain_water_mode,switch.solar_plainwatermode SM50,solar,162,doublematchflow,doublematchflow,boolean, ,true,switch.solar_doublematchflow,switch.solar_doublematchflow -SM50,solar,162,pump2minmod,minimum pump 2 modulation,uint (>=0<=100),%,true,number.solar_minimum_pump_2_modulation,number.solar_pump2minmod -SM50,solar,162,turnondiff2,pump 2 turn on difference,uint (>=0<=25),C,true,number.solar_pump_2_turn_on_difference,number.solar_turnondiff2 -SM50,solar,162,turnoffdiff2,pump 2 turn off difference,uint (>=0<=25),C,true,number.solar_pump_2_turn_off_difference,number.solar_turnoffdiff2 +SM50,solar,162,pump2minmod,minimum pump 2 modulation,uint8 (>=0<=100),%,true,number.solar_minimum_pump_2_modulation,number.solar_pump2minmod +SM50,solar,162,turnondiff2,pump 2 turn on difference,uint8 (>=0<=25),C,true,number.solar_pump_2_turn_on_difference,number.solar_turnondiff2 +SM50,solar,162,turnoffdiff2,pump 2 turn off difference,uint8 (>=0<=25),C,true,number.solar_pump_2_turn_off_difference,number.solar_turnoffdiff2 SM50,solar,162,pump2kick,pump kick 2,boolean, ,true,switch.solar_pump_kick_2,switch.solar_pump2kick -SM50,solar,162,climatezone,climate zone,uint (>=0<=254), ,true,number.solar_climate_zone,number.solar_climatezone -SM50,solar,162,collector1area,collector 1 area,ushort (>=0<=3199),m²,true,number.solar_collector_1_area,number.solar_collector1area +SM50,solar,162,climatezone,climate zone,uint8 (>=0<=254), ,true,number.solar_climate_zone,number.solar_climatezone +SM50,solar,162,collector1area,collector 1 area,uint16 (>=0<=3199),m²,true,number.solar_collector_1_area,number.solar_collector1area SM50,solar,162,collector1type,collector 1 type,enum [flat\|vacuum], ,true,select.solar_collector_1_type,select.solar_collector1type -SM50,solar,162,collector2area,collector 2 area,ushort (>=0<=3199),m²,true,number.solar_collector_2_area,number.solar_collector2area +SM50,solar,162,collector2area,collector 2 area,uint16 (>=0<=3199),m²,true,number.solar_collector_2_area,number.solar_collector2area SM50,solar,162,collector2type,collector 2 type,enum [flat\|vacuum], ,true,select.solar_collector_2_type,select.solar_collector2type SM50,solar,162,cylpriority,cylinder priority,enum [cyl 1\|cyl 2], ,true,select.solar_cylinder_priority,select.solar_cylpriority -SM50,solar,162,heatcntflowtemp,heat counter flow temperature,ushort (>=0<=3199),C,false,sensor.solar_heat_counter_flow_temperature,sensor.solar_heatcntflowtemp -SM50,solar,162,heatcntrettemp,heat counter return temperature,ushort (>=0<=3199),C,false,sensor.solar_heat_counter_return_temperature,sensor.solar_heatcntrettemp -SM50,solar,162,heatcnt,heat counter impulses,uint (>=0<=254), ,false,sensor.solar_heat_counter_impulses,sensor.solar_heatcnt -SM50,solar,162,swapflowtemp,swap flow temperature (TS14),ushort (>=0<=3199),C,false,sensor.solar_swap_flow_temperature_(TS14),sensor.solar_swapflowtemp -SM50,solar,162,swaprettemp,swap return temperature (TS15),ushort (>=0<=3199),C,false,sensor.solar_swap_return_temperature_(TS15),sensor.solar_swaprettemp -SM100/MS100,solar,163,collectortemp,collector temperature (TS1),short (>=-3199<=3199),C,false,sensor.solar_collector_temperature_(TS1),sensor.solar_collectortemp -SM100/MS100,solar,163,cylbottomtemp,cylinder bottom temperature (TS2),short (>=-3199<=3199),C,false,sensor.solar_cylinder_bottom_temperature_(TS2),sensor.solar_cylbottomtemp +SM50,solar,162,heatcntflowtemp,heat counter flow temperature,uint16 (>=0<=3199),C,false,sensor.solar_heat_counter_flow_temperature,sensor.solar_heatcntflowtemp +SM50,solar,162,heatcntrettemp,heat counter return temperature,uint16 (>=0<=3199),C,false,sensor.solar_heat_counter_return_temperature,sensor.solar_heatcntrettemp +SM50,solar,162,heatcnt,heat counter impulses,uint8 (>=0<=254), ,false,sensor.solar_heat_counter_impulses,sensor.solar_heatcnt +SM50,solar,162,swapflowtemp,swap flow temperature (TS14),uint16 (>=0<=3199),C,false,sensor.solar_swap_flow_temperature_(TS14),sensor.solar_swapflowtemp +SM50,solar,162,swaprettemp,swap return temperature (TS15),uint16 (>=0<=3199),C,false,sensor.solar_swap_return_temperature_(TS15),sensor.solar_swaprettemp +SM100/MS100,solar,163,collectortemp,collector temperature (TS1),int16 (>=-3199<=3199),C,false,sensor.solar_collector_temperature_(TS1),sensor.solar_collectortemp +SM100/MS100,solar,163,cylbottomtemp,cylinder bottom temperature (TS2),int16 (>=-3199<=3199),C,false,sensor.solar_cylinder_bottom_temperature_(TS2),sensor.solar_cylbottomtemp SM100/MS100,solar,163,solarpump,pump (PS1),boolean, ,false,binary_sensor.solar_pump_(PS1),binary_sensor.solar_solarpump SM100/MS100,solar,163,pumpworktime,pump working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_working_time,sensor.solar_pumpworktime -SM100/MS100,solar,163,cylmaxtemp,maximum cylinder temperature,uint (>=0<=254),C,true,number.solar_maximum_cylinder_temperature,number.solar_cylmaxtemp +SM100/MS100,solar,163,cylmaxtemp,maximum cylinder temperature,uint8 (>=0<=254),C,true,number.solar_maximum_cylinder_temperature,number.solar_cylmaxtemp SM100/MS100,solar,163,collectorshutdown,collector shutdown,boolean, ,false,binary_sensor.solar_collector_shutdown,binary_sensor.solar_collectorshutdown SM100/MS100,solar,163,cylheated,cyl heated,boolean, ,false,binary_sensor.solar_cyl_heated,binary_sensor.solar_cylheated -SM100/MS100,solar,163,solarpumpmod,pump modulation (PS1),uint (>=0<=100),%,false,sensor.solar_pump_modulation_(PS1),sensor.solar_solarpumpmod -SM100/MS100,solar,163,pumpminmod,minimum pump modulation,uint (>=0<=100),%,true,number.solar_minimum_pump_modulation,number.solar_pumpminmod -SM100/MS100,solar,163,turnondiff,pump turn on difference,uint (>=0<=25),C,true,number.solar_pump_turn_on_difference,number.solar_turnondiff -SM100/MS100,solar,163,turnoffdiff,pump turn off difference,uint (>=0<=25),C,true,number.solar_pump_turn_off_difference,number.solar_turnoffdiff -SM100/MS100,solar,163,collector2temp,collector 2 temperature (TS7),short (>=-3199<=3199),C,false,sensor.solar_collector_2_temperature_(TS7),sensor.solar_collector2temp -SM100/MS100,solar,163,cylmiddletemp,cylinder middle temperature (TS3),short (>=-3199<=3199),C,false,sensor.solar_cylinder_middle_temperature_(TS3),sensor.solar_cylmiddletemp -SM100/MS100,solar,163,retheatassist,return temperature heat assistance (TS4),short (>=-3199<=3199),C,false,sensor.solar_return_temperature_heat_assistance_(TS4),sensor.solar_retheatassist +SM100/MS100,solar,163,solarpumpmod,pump modulation (PS1),uint8 (>=0<=100),%,false,sensor.solar_pump_modulation_(PS1),sensor.solar_solarpumpmod +SM100/MS100,solar,163,pumpminmod,minimum pump modulation,uint8 (>=0<=100),%,true,number.solar_minimum_pump_modulation,number.solar_pumpminmod +SM100/MS100,solar,163,turnondiff,pump turn on difference,uint8 (>=0<=25),C,true,number.solar_pump_turn_on_difference,number.solar_turnondiff +SM100/MS100,solar,163,turnoffdiff,pump turn off difference,uint8 (>=0<=25),C,true,number.solar_pump_turn_off_difference,number.solar_turnoffdiff +SM100/MS100,solar,163,collector2temp,collector 2 temperature (TS7),int16 (>=-3199<=3199),C,false,sensor.solar_collector_2_temperature_(TS7),sensor.solar_collector2temp +SM100/MS100,solar,163,cylmiddletemp,cylinder middle temperature (TS3),int16 (>=-3199<=3199),C,false,sensor.solar_cylinder_middle_temperature_(TS3),sensor.solar_cylmiddletemp +SM100/MS100,solar,163,retheatassist,return temperature heat assistance (TS4),int16 (>=-3199<=3199),C,false,sensor.solar_return_temperature_heat_assistance_(TS4),sensor.solar_retheatassist SM100/MS100,solar,163,heatassistvalve,heat assistance valve (M1),boolean, ,false,binary_sensor.solar_heat_assistance_valve_(M1),binary_sensor.solar_heatassistvalve -SM100/MS100,solar,163,heatassistpower,heat assistance valve power (M1),uint (>=0<=100),%,false,sensor.solar_heat_assistance_valve_power_(M1),sensor.solar_heatassistpower +SM100/MS100,solar,163,heatassistpower,heat assistance valve power (M1),uint8 (>=0<=100),%,false,sensor.solar_heat_assistance_valve_power_(M1),sensor.solar_heatassistpower SM100/MS100,solar,163,solarpump2,pump 2 (PS4),boolean, ,false,binary_sensor.solar_pump_2_(PS4),binary_sensor.solar_solarpump2 -SM100/MS100,solar,163,solarpump2mod,pump 2 modulation (PS4),uint (>=0<=100),%,false,sensor.solar_pump_2_modulation_(PS4),sensor.solar_solarpump2mod -SM100/MS100,solar,163,cyl2bottomtemp,second cylinder bottom temperature (TS5),short (>=-3199<=3199),C,false,sensor.solar_second_cylinder_bottom_temperature_(TS5),sensor.solar_cyl2bottomtemp -SM100/MS100,solar,163,heatexchangertemp,heat exchanger temperature (TS6),short (>=-3199<=3199),C,false,sensor.solar_heat_exchanger_temperature_(TS6),sensor.solar_heatexchangertemp -SM100/MS100,solar,163,cylpumpmod,cylinder pump modulation (PS5),uint (>=0<=100),%,false,sensor.solar_cylinder_pump_modulation_(PS5),sensor.solar_cylpumpmod +SM100/MS100,solar,163,solarpump2mod,pump 2 modulation (PS4),uint8 (>=0<=100),%,false,sensor.solar_pump_2_modulation_(PS4),sensor.solar_solarpump2mod +SM100/MS100,solar,163,cyl2bottomtemp,second cylinder bottom temperature (TS5),int16 (>=-3199<=3199),C,false,sensor.solar_second_cylinder_bottom_temperature_(TS5),sensor.solar_cyl2bottomtemp +SM100/MS100,solar,163,heatexchangertemp,heat exchanger temperature (TS6),int16 (>=-3199<=3199),C,false,sensor.solar_heat_exchanger_temperature_(TS6),sensor.solar_heatexchangertemp +SM100/MS100,solar,163,cylpumpmod,cylinder pump modulation (PS5),uint8 (>=0<=100),%,false,sensor.solar_cylinder_pump_modulation_(PS5),sensor.solar_cylpumpmod SM100/MS100,solar,163,valvestatus,valve status,boolean, ,false,binary_sensor.solar_valve_status,binary_sensor.solar_valvestatus SM100/MS100,solar,163,vs1status,valve status VS1,boolean, ,false,binary_sensor.solar_valve_status_VS1,binary_sensor.solar_vs1status -SM100/MS100,solar,163,collectormaxtemp,maximum collector temperature,uint (>=0<=254),C,true,number.solar_maximum_collector_temperature,number.solar_collectormaxtemp -SM100/MS100,solar,163,collectormintemp,minimum collector temperature,uint (>=0<=254),C,true,number.solar_minimum_collector_temperature,number.solar_collectormintemp -SM100/MS100,solar,163,energylasthour,energy last hour,ulong (>=0<=1677721),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour -SM100/MS100,solar,163,energytoday,total energy today,ulong (>=0<=16777213),Wh,false,sensor.solar_total_energy_today,sensor.solar_energytoday -SM100/MS100,solar,163,energytotal,total energy,ulong (>=0<=1677721),kWh,false,sensor.solar_total_energy,sensor.solar_energytotal +SM100/MS100,solar,163,collectormaxtemp,maximum collector temperature,uint8 (>=0<=254),C,true,number.solar_maximum_collector_temperature,number.solar_collectormaxtemp +SM100/MS100,solar,163,collectormintemp,minimum collector temperature,uint8 (>=0<=254),C,true,number.solar_minimum_collector_temperature,number.solar_collectormintemp +SM100/MS100,solar,163,energylasthour,energy last hour,uint24 (>=0<=1677721),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour +SM100/MS100,solar,163,energytoday,total energy today,uint24 (>=0<=16777213),Wh,false,sensor.solar_total_energy_today,sensor.solar_energytoday +SM100/MS100,solar,163,energytotal,total energy,uint24 (>=0<=1677721),kWh,false,sensor.solar_total_energy,sensor.solar_energytotal SM100/MS100,solar,163,pump2worktime,pump 2 working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_2_working_time,sensor.solar_pump2worktime SM100/MS100,solar,163,m1worktime,differential control working time,time (>=0<=16777213),minutes,false,sensor.solar_differential_control_working_time,sensor.solar_m1worktime SM100/MS100,solar,163,heattransfersystem,heattransfer system,boolean, ,true,switch.solar_heattransfer_system,switch.solar_heattransfersystem @@ -4784,49 +4880,49 @@ SM100/MS100,solar,163,solarpumpmode,pump mode,enum [constant\|pwm\|analog], ,tru SM100/MS100,solar,163,pumpkick,pump kick,boolean, ,true,switch.solar_pump_kick,switch.solar_pumpkick SM100/MS100,solar,163,plainwatermode,plain water mode,boolean, ,true,switch.solar_plain_water_mode,switch.solar_plainwatermode SM100/MS100,solar,163,doublematchflow,doublematchflow,boolean, ,true,switch.solar_doublematchflow,switch.solar_doublematchflow -SM100/MS100,solar,163,pump2minmod,minimum pump 2 modulation,uint (>=0<=100),%,true,number.solar_minimum_pump_2_modulation,number.solar_pump2minmod -SM100/MS100,solar,163,turnondiff2,pump 2 turn on difference,uint (>=0<=25),C,true,number.solar_pump_2_turn_on_difference,number.solar_turnondiff2 -SM100/MS100,solar,163,turnoffdiff2,pump 2 turn off difference,uint (>=0<=25),C,true,number.solar_pump_2_turn_off_difference,number.solar_turnoffdiff2 +SM100/MS100,solar,163,pump2minmod,minimum pump 2 modulation,uint8 (>=0<=100),%,true,number.solar_minimum_pump_2_modulation,number.solar_pump2minmod +SM100/MS100,solar,163,turnondiff2,pump 2 turn on difference,uint8 (>=0<=25),C,true,number.solar_pump_2_turn_on_difference,number.solar_turnondiff2 +SM100/MS100,solar,163,turnoffdiff2,pump 2 turn off difference,uint8 (>=0<=25),C,true,number.solar_pump_2_turn_off_difference,number.solar_turnoffdiff2 SM100/MS100,solar,163,pump2kick,pump kick 2,boolean, ,true,switch.solar_pump_kick_2,switch.solar_pump2kick -SM100/MS100,solar,163,climatezone,climate zone,uint (>=0<=254), ,true,number.solar_climate_zone,number.solar_climatezone -SM100/MS100,solar,163,collector1area,collector 1 area,ushort (>=0<=3199),m²,true,number.solar_collector_1_area,number.solar_collector1area +SM100/MS100,solar,163,climatezone,climate zone,uint8 (>=0<=254), ,true,number.solar_climate_zone,number.solar_climatezone +SM100/MS100,solar,163,collector1area,collector 1 area,uint16 (>=0<=3199),m²,true,number.solar_collector_1_area,number.solar_collector1area SM100/MS100,solar,163,collector1type,collector 1 type,enum [flat\|vacuum], ,true,select.solar_collector_1_type,select.solar_collector1type -SM100/MS100,solar,163,collector2area,collector 2 area,ushort (>=0<=3199),m²,true,number.solar_collector_2_area,number.solar_collector2area +SM100/MS100,solar,163,collector2area,collector 2 area,uint16 (>=0<=3199),m²,true,number.solar_collector_2_area,number.solar_collector2area SM100/MS100,solar,163,collector2type,collector 2 type,enum [flat\|vacuum], ,true,select.solar_collector_2_type,select.solar_collector2type SM100/MS100,solar,163,cylpriority,cylinder priority,enum [cyl 1\|cyl 2], ,true,select.solar_cylinder_priority,select.solar_cylpriority -SM100/MS100,solar,163,heatcntflowtemp,heat counter flow temperature,ushort (>=0<=3199),C,false,sensor.solar_heat_counter_flow_temperature,sensor.solar_heatcntflowtemp -SM100/MS100,solar,163,heatcntrettemp,heat counter return temperature,ushort (>=0<=3199),C,false,sensor.solar_heat_counter_return_temperature,sensor.solar_heatcntrettemp -SM100/MS100,solar,163,heatcnt,heat counter impulses,uint (>=0<=254), ,false,sensor.solar_heat_counter_impulses,sensor.solar_heatcnt -SM100/MS100,solar,163,swapflowtemp,swap flow temperature (TS14),ushort (>=0<=3199),C,false,sensor.solar_swap_flow_temperature_(TS14),sensor.solar_swapflowtemp -SM100/MS100,solar,163,swaprettemp,swap return temperature (TS15),ushort (>=0<=3199),C,false,sensor.solar_swap_return_temperature_(TS15),sensor.solar_swaprettemp -SM200/MS200,solar,164,collectortemp,collector temperature (TS1),short (>=-3199<=3199),C,false,sensor.solar_collector_temperature_(TS1),sensor.solar_collectortemp -SM200/MS200,solar,164,cylbottomtemp,cylinder bottom temperature (TS2),short (>=-3199<=3199),C,false,sensor.solar_cylinder_bottom_temperature_(TS2),sensor.solar_cylbottomtemp +SM100/MS100,solar,163,heatcntflowtemp,heat counter flow temperature,uint16 (>=0<=3199),C,false,sensor.solar_heat_counter_flow_temperature,sensor.solar_heatcntflowtemp +SM100/MS100,solar,163,heatcntrettemp,heat counter return temperature,uint16 (>=0<=3199),C,false,sensor.solar_heat_counter_return_temperature,sensor.solar_heatcntrettemp +SM100/MS100,solar,163,heatcnt,heat counter impulses,uint8 (>=0<=254), ,false,sensor.solar_heat_counter_impulses,sensor.solar_heatcnt +SM100/MS100,solar,163,swapflowtemp,swap flow temperature (TS14),uint16 (>=0<=3199),C,false,sensor.solar_swap_flow_temperature_(TS14),sensor.solar_swapflowtemp +SM100/MS100,solar,163,swaprettemp,swap return temperature (TS15),uint16 (>=0<=3199),C,false,sensor.solar_swap_return_temperature_(TS15),sensor.solar_swaprettemp +SM200/MS200,solar,164,collectortemp,collector temperature (TS1),int16 (>=-3199<=3199),C,false,sensor.solar_collector_temperature_(TS1),sensor.solar_collectortemp +SM200/MS200,solar,164,cylbottomtemp,cylinder bottom temperature (TS2),int16 (>=-3199<=3199),C,false,sensor.solar_cylinder_bottom_temperature_(TS2),sensor.solar_cylbottomtemp SM200/MS200,solar,164,solarpump,pump (PS1),boolean, ,false,binary_sensor.solar_pump_(PS1),binary_sensor.solar_solarpump SM200/MS200,solar,164,pumpworktime,pump working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_working_time,sensor.solar_pumpworktime -SM200/MS200,solar,164,cylmaxtemp,maximum cylinder temperature,uint (>=0<=254),C,true,number.solar_maximum_cylinder_temperature,number.solar_cylmaxtemp +SM200/MS200,solar,164,cylmaxtemp,maximum cylinder temperature,uint8 (>=0<=254),C,true,number.solar_maximum_cylinder_temperature,number.solar_cylmaxtemp SM200/MS200,solar,164,collectorshutdown,collector shutdown,boolean, ,false,binary_sensor.solar_collector_shutdown,binary_sensor.solar_collectorshutdown SM200/MS200,solar,164,cylheated,cyl heated,boolean, ,false,binary_sensor.solar_cyl_heated,binary_sensor.solar_cylheated -SM200/MS200,solar,164,solarpumpmod,pump modulation (PS1),uint (>=0<=100),%,false,sensor.solar_pump_modulation_(PS1),sensor.solar_solarpumpmod -SM200/MS200,solar,164,pumpminmod,minimum pump modulation,uint (>=0<=100),%,true,number.solar_minimum_pump_modulation,number.solar_pumpminmod -SM200/MS200,solar,164,turnondiff,pump turn on difference,uint (>=0<=25),C,true,number.solar_pump_turn_on_difference,number.solar_turnondiff -SM200/MS200,solar,164,turnoffdiff,pump turn off difference,uint (>=0<=25),C,true,number.solar_pump_turn_off_difference,number.solar_turnoffdiff -SM200/MS200,solar,164,collector2temp,collector 2 temperature (TS7),short (>=-3199<=3199),C,false,sensor.solar_collector_2_temperature_(TS7),sensor.solar_collector2temp -SM200/MS200,solar,164,cylmiddletemp,cylinder middle temperature (TS3),short (>=-3199<=3199),C,false,sensor.solar_cylinder_middle_temperature_(TS3),sensor.solar_cylmiddletemp -SM200/MS200,solar,164,retheatassist,return temperature heat assistance (TS4),short (>=-3199<=3199),C,false,sensor.solar_return_temperature_heat_assistance_(TS4),sensor.solar_retheatassist +SM200/MS200,solar,164,solarpumpmod,pump modulation (PS1),uint8 (>=0<=100),%,false,sensor.solar_pump_modulation_(PS1),sensor.solar_solarpumpmod +SM200/MS200,solar,164,pumpminmod,minimum pump modulation,uint8 (>=0<=100),%,true,number.solar_minimum_pump_modulation,number.solar_pumpminmod +SM200/MS200,solar,164,turnondiff,pump turn on difference,uint8 (>=0<=25),C,true,number.solar_pump_turn_on_difference,number.solar_turnondiff +SM200/MS200,solar,164,turnoffdiff,pump turn off difference,uint8 (>=0<=25),C,true,number.solar_pump_turn_off_difference,number.solar_turnoffdiff +SM200/MS200,solar,164,collector2temp,collector 2 temperature (TS7),int16 (>=-3199<=3199),C,false,sensor.solar_collector_2_temperature_(TS7),sensor.solar_collector2temp +SM200/MS200,solar,164,cylmiddletemp,cylinder middle temperature (TS3),int16 (>=-3199<=3199),C,false,sensor.solar_cylinder_middle_temperature_(TS3),sensor.solar_cylmiddletemp +SM200/MS200,solar,164,retheatassist,return temperature heat assistance (TS4),int16 (>=-3199<=3199),C,false,sensor.solar_return_temperature_heat_assistance_(TS4),sensor.solar_retheatassist SM200/MS200,solar,164,heatassistvalve,heat assistance valve (M1),boolean, ,false,binary_sensor.solar_heat_assistance_valve_(M1),binary_sensor.solar_heatassistvalve -SM200/MS200,solar,164,heatassistpower,heat assistance valve power (M1),uint (>=0<=100),%,false,sensor.solar_heat_assistance_valve_power_(M1),sensor.solar_heatassistpower +SM200/MS200,solar,164,heatassistpower,heat assistance valve power (M1),uint8 (>=0<=100),%,false,sensor.solar_heat_assistance_valve_power_(M1),sensor.solar_heatassistpower SM200/MS200,solar,164,solarpump2,pump 2 (PS4),boolean, ,false,binary_sensor.solar_pump_2_(PS4),binary_sensor.solar_solarpump2 -SM200/MS200,solar,164,solarpump2mod,pump 2 modulation (PS4),uint (>=0<=100),%,false,sensor.solar_pump_2_modulation_(PS4),sensor.solar_solarpump2mod -SM200/MS200,solar,164,cyl2bottomtemp,second cylinder bottom temperature (TS5),short (>=-3199<=3199),C,false,sensor.solar_second_cylinder_bottom_temperature_(TS5),sensor.solar_cyl2bottomtemp -SM200/MS200,solar,164,heatexchangertemp,heat exchanger temperature (TS6),short (>=-3199<=3199),C,false,sensor.solar_heat_exchanger_temperature_(TS6),sensor.solar_heatexchangertemp -SM200/MS200,solar,164,cylpumpmod,cylinder pump modulation (PS5),uint (>=0<=100),%,false,sensor.solar_cylinder_pump_modulation_(PS5),sensor.solar_cylpumpmod +SM200/MS200,solar,164,solarpump2mod,pump 2 modulation (PS4),uint8 (>=0<=100),%,false,sensor.solar_pump_2_modulation_(PS4),sensor.solar_solarpump2mod +SM200/MS200,solar,164,cyl2bottomtemp,second cylinder bottom temperature (TS5),int16 (>=-3199<=3199),C,false,sensor.solar_second_cylinder_bottom_temperature_(TS5),sensor.solar_cyl2bottomtemp +SM200/MS200,solar,164,heatexchangertemp,heat exchanger temperature (TS6),int16 (>=-3199<=3199),C,false,sensor.solar_heat_exchanger_temperature_(TS6),sensor.solar_heatexchangertemp +SM200/MS200,solar,164,cylpumpmod,cylinder pump modulation (PS5),uint8 (>=0<=100),%,false,sensor.solar_cylinder_pump_modulation_(PS5),sensor.solar_cylpumpmod SM200/MS200,solar,164,valvestatus,valve status,boolean, ,false,binary_sensor.solar_valve_status,binary_sensor.solar_valvestatus SM200/MS200,solar,164,vs1status,valve status VS1,boolean, ,false,binary_sensor.solar_valve_status_VS1,binary_sensor.solar_vs1status -SM200/MS200,solar,164,collectormaxtemp,maximum collector temperature,uint (>=0<=254),C,true,number.solar_maximum_collector_temperature,number.solar_collectormaxtemp -SM200/MS200,solar,164,collectormintemp,minimum collector temperature,uint (>=0<=254),C,true,number.solar_minimum_collector_temperature,number.solar_collectormintemp -SM200/MS200,solar,164,energylasthour,energy last hour,ulong (>=0<=1677721),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour -SM200/MS200,solar,164,energytoday,total energy today,ulong (>=0<=16777213),Wh,false,sensor.solar_total_energy_today,sensor.solar_energytoday -SM200/MS200,solar,164,energytotal,total energy,ulong (>=0<=1677721),kWh,false,sensor.solar_total_energy,sensor.solar_energytotal +SM200/MS200,solar,164,collectormaxtemp,maximum collector temperature,uint8 (>=0<=254),C,true,number.solar_maximum_collector_temperature,number.solar_collectormaxtemp +SM200/MS200,solar,164,collectormintemp,minimum collector temperature,uint8 (>=0<=254),C,true,number.solar_minimum_collector_temperature,number.solar_collectormintemp +SM200/MS200,solar,164,energylasthour,energy last hour,uint24 (>=0<=1677721),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour +SM200/MS200,solar,164,energytoday,total energy today,uint24 (>=0<=16777213),Wh,false,sensor.solar_total_energy_today,sensor.solar_energytoday +SM200/MS200,solar,164,energytotal,total energy,uint24 (>=0<=1677721),kWh,false,sensor.solar_total_energy,sensor.solar_energytotal SM200/MS200,solar,164,pump2worktime,pump 2 working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_2_working_time,sensor.solar_pump2worktime SM200/MS200,solar,164,m1worktime,differential control working time,time (>=0<=16777213),minutes,false,sensor.solar_differential_control_working_time,sensor.solar_m1worktime SM200/MS200,solar,164,heattransfersystem,heattransfer system,boolean, ,true,switch.solar_heattransfer_system,switch.solar_heattransfersystem @@ -4838,134 +4934,134 @@ SM200/MS200,solar,164,solarpumpmode,pump mode,enum [constant\|pwm\|analog], ,tru SM200/MS200,solar,164,pumpkick,pump kick,boolean, ,true,switch.solar_pump_kick,switch.solar_pumpkick SM200/MS200,solar,164,plainwatermode,plain water mode,boolean, ,true,switch.solar_plain_water_mode,switch.solar_plainwatermode SM200/MS200,solar,164,doublematchflow,doublematchflow,boolean, ,true,switch.solar_doublematchflow,switch.solar_doublematchflow -SM200/MS200,solar,164,pump2minmod,minimum pump 2 modulation,uint (>=0<=100),%,true,number.solar_minimum_pump_2_modulation,number.solar_pump2minmod -SM200/MS200,solar,164,turnondiff2,pump 2 turn on difference,uint (>=0<=25),C,true,number.solar_pump_2_turn_on_difference,number.solar_turnondiff2 -SM200/MS200,solar,164,turnoffdiff2,pump 2 turn off difference,uint (>=0<=25),C,true,number.solar_pump_2_turn_off_difference,number.solar_turnoffdiff2 +SM200/MS200,solar,164,pump2minmod,minimum pump 2 modulation,uint8 (>=0<=100),%,true,number.solar_minimum_pump_2_modulation,number.solar_pump2minmod +SM200/MS200,solar,164,turnondiff2,pump 2 turn on difference,uint8 (>=0<=25),C,true,number.solar_pump_2_turn_on_difference,number.solar_turnondiff2 +SM200/MS200,solar,164,turnoffdiff2,pump 2 turn off difference,uint8 (>=0<=25),C,true,number.solar_pump_2_turn_off_difference,number.solar_turnoffdiff2 SM200/MS200,solar,164,pump2kick,pump kick 2,boolean, ,true,switch.solar_pump_kick_2,switch.solar_pump2kick -SM200/MS200,solar,164,climatezone,climate zone,uint (>=0<=254), ,true,number.solar_climate_zone,number.solar_climatezone -SM200/MS200,solar,164,collector1area,collector 1 area,ushort (>=0<=3199),m²,true,number.solar_collector_1_area,number.solar_collector1area +SM200/MS200,solar,164,climatezone,climate zone,uint8 (>=0<=254), ,true,number.solar_climate_zone,number.solar_climatezone +SM200/MS200,solar,164,collector1area,collector 1 area,uint16 (>=0<=3199),m²,true,number.solar_collector_1_area,number.solar_collector1area SM200/MS200,solar,164,collector1type,collector 1 type,enum [flat\|vacuum], ,true,select.solar_collector_1_type,select.solar_collector1type -SM200/MS200,solar,164,collector2area,collector 2 area,ushort (>=0<=3199),m²,true,number.solar_collector_2_area,number.solar_collector2area +SM200/MS200,solar,164,collector2area,collector 2 area,uint16 (>=0<=3199),m²,true,number.solar_collector_2_area,number.solar_collector2area SM200/MS200,solar,164,collector2type,collector 2 type,enum [flat\|vacuum], ,true,select.solar_collector_2_type,select.solar_collector2type SM200/MS200,solar,164,cylpriority,cylinder priority,enum [cyl 1\|cyl 2], ,true,select.solar_cylinder_priority,select.solar_cylpriority -SM200/MS200,solar,164,heatcntflowtemp,heat counter flow temperature,ushort (>=0<=3199),C,false,sensor.solar_heat_counter_flow_temperature,sensor.solar_heatcntflowtemp -SM200/MS200,solar,164,heatcntrettemp,heat counter return temperature,ushort (>=0<=3199),C,false,sensor.solar_heat_counter_return_temperature,sensor.solar_heatcntrettemp -SM200/MS200,solar,164,heatcnt,heat counter impulses,uint (>=0<=254), ,false,sensor.solar_heat_counter_impulses,sensor.solar_heatcnt -SM200/MS200,solar,164,swapflowtemp,swap flow temperature (TS14),ushort (>=0<=3199),C,false,sensor.solar_swap_flow_temperature_(TS14),sensor.solar_swapflowtemp -SM200/MS200,solar,164,swaprettemp,swap return temperature (TS15),ushort (>=0<=3199),C,false,sensor.solar_swap_return_temperature_(TS15),sensor.solar_swaprettemp -HP Module,heatpump,252,airhumidity,relative air humidity,uint (>=0<=100),%,false,sensor.heatpump_relative_air_humidity,sensor.heatpump_airhumidity -HP Module,heatpump,252,dewtemperature,dew point temperature,uint (>=0<=254),C,false,sensor.heatpump_dew_point_temperature,sensor.heatpump_dewtemperature -HP Module,heatpump,252,curflowtemp,current flow temperature,short (>=-3199<=3199),C,false,sensor.heatpump_current_flow_temperature,sensor.heatpump_curflowtemp -HP Module,heatpump,252,rettemp,return temperature,short (>=-3199<=3199),C,false,sensor.heatpump_return_temperature,sensor.heatpump_rettemp -HP Module,heatpump,252,sysrettemp,system return temperature,short (>=-3199<=3199),C,false,sensor.heatpump_system_return_temperature,sensor.heatpump_sysrettemp -HP Module,heatpump,252,hpta4,drain pan temp (TA4),short (>=-3199<=3199),C,false,sensor.heatpump_drain_pan_temp_(TA4),sensor.heatpump_hpta4 -HP Module,heatpump,252,hptr1,compressor temperature (TR1),short (>=-3199<=3199),C,false,sensor.heatpump_compressor_temperature_(TR1),sensor.heatpump_hptr1 -HP Module,heatpump,252,hptr3,refrigerant temperature liquid side (condenser output) (TR3),short (>=-3199<=3199),C,false,sensor.heatpump_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.heatpump_hptr3 -HP Module,heatpump,252,hptr4,evaporator inlet temperature (TR4),short (>=-3199<=3199),C,false,sensor.heatpump_evaporator_inlet_temperature_(TR4),sensor.heatpump_hptr4 -HP Module,heatpump,252,hptr5,compressor inlet temperature (TR5),short (>=-3199<=3199),C,false,sensor.heatpump_compressor_inlet_temperature_(TR5),sensor.heatpump_hptr5 -HP Module,heatpump,252,hptr6,compressor outlet temperature (TR6),short (>=-3199<=3199),C,false,sensor.heatpump_compressor_outlet_temperature_(TR6),sensor.heatpump_hptr6 -HP Module,heatpump,252,hptl2,air inlet temperature (TL2),short (>=-3199<=3199),C,false,sensor.heatpump_air_inlet_temperature_(TL2),sensor.heatpump_hptl2 -HP Module,heatpump,252,hppl1,low pressure side temperature (PL1),short (>=-3199<=3199),C,false,sensor.heatpump_low_pressure_side_temperature_(PL1),sensor.heatpump_hppl1 -HP Module,heatpump,252,hpph1,high pressure side temperature (PH1),short (>=-3199<=3199),C,false,sensor.heatpump_high_pressure_side_temperature_(PH1),sensor.heatpump_hpph1 -HP Module,heatpump,252,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.heatpump_heating_pump_modulation,sensor.heatpump_heatingpumpmod -HP Module,heatpump,252,hpcompspd,compressor speed,uint (>=0<=100),%,false,sensor.heatpump_compressor_speed,sensor.heatpump_hpcompspd +SM200/MS200,solar,164,heatcntflowtemp,heat counter flow temperature,uint16 (>=0<=3199),C,false,sensor.solar_heat_counter_flow_temperature,sensor.solar_heatcntflowtemp +SM200/MS200,solar,164,heatcntrettemp,heat counter return temperature,uint16 (>=0<=3199),C,false,sensor.solar_heat_counter_return_temperature,sensor.solar_heatcntrettemp +SM200/MS200,solar,164,heatcnt,heat counter impulses,uint8 (>=0<=254), ,false,sensor.solar_heat_counter_impulses,sensor.solar_heatcnt +SM200/MS200,solar,164,swapflowtemp,swap flow temperature (TS14),uint16 (>=0<=3199),C,false,sensor.solar_swap_flow_temperature_(TS14),sensor.solar_swapflowtemp +SM200/MS200,solar,164,swaprettemp,swap return temperature (TS15),uint16 (>=0<=3199),C,false,sensor.solar_swap_return_temperature_(TS15),sensor.solar_swaprettemp +HP Module,heatpump,252,airhumidity,relative air humidity,uint8 (>=0<=100),%,false,sensor.heatpump_relative_air_humidity,sensor.heatpump_airhumidity +HP Module,heatpump,252,dewtemperature,dew point temperature,uint8 (>=0<=254),C,false,sensor.heatpump_dew_point_temperature,sensor.heatpump_dewtemperature +HP Module,heatpump,252,curflowtemp,current flow temperature,int16 (>=-3199<=3199),C,false,sensor.heatpump_current_flow_temperature,sensor.heatpump_curflowtemp +HP Module,heatpump,252,rettemp,return temperature,int16 (>=-3199<=3199),C,false,sensor.heatpump_return_temperature,sensor.heatpump_rettemp +HP Module,heatpump,252,sysrettemp,system return temperature,int16 (>=-3199<=3199),C,false,sensor.heatpump_system_return_temperature,sensor.heatpump_sysrettemp +HP Module,heatpump,252,hpta4,drain pan temp (TA4),int16 (>=-3199<=3199),C,false,sensor.heatpump_drain_pan_temp_(TA4),sensor.heatpump_hpta4 +HP Module,heatpump,252,hptr1,compressor temperature (TR1),int16 (>=-3199<=3199),C,false,sensor.heatpump_compressor_temperature_(TR1),sensor.heatpump_hptr1 +HP Module,heatpump,252,hptr3,refrigerant temperature liquid side (condenser output) (TR3),int16 (>=-3199<=3199),C,false,sensor.heatpump_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.heatpump_hptr3 +HP Module,heatpump,252,hptr4,evaporator inlet temperature (TR4),int16 (>=-3199<=3199),C,false,sensor.heatpump_evaporator_inlet_temperature_(TR4),sensor.heatpump_hptr4 +HP Module,heatpump,252,hptr5,compressor inlet temperature (TR5),int16 (>=-3199<=3199),C,false,sensor.heatpump_compressor_inlet_temperature_(TR5),sensor.heatpump_hptr5 +HP Module,heatpump,252,hptr6,compressor outlet temperature (TR6),int16 (>=-3199<=3199),C,false,sensor.heatpump_compressor_outlet_temperature_(TR6),sensor.heatpump_hptr6 +HP Module,heatpump,252,hptl2,air inlet temperature (TL2),int16 (>=-3199<=3199),C,false,sensor.heatpump_air_inlet_temperature_(TL2),sensor.heatpump_hptl2 +HP Module,heatpump,252,hppl1,low pressure side temperature (PL1),int16 (>=-3199<=3199),C,false,sensor.heatpump_low_pressure_side_temperature_(PL1),sensor.heatpump_hppl1 +HP Module,heatpump,252,hpph1,high pressure side temperature (PH1),int16 (>=-3199<=3199),C,false,sensor.heatpump_high_pressure_side_temperature_(PH1),sensor.heatpump_hpph1 +HP Module,heatpump,252,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.heatpump_heating_pump_modulation,sensor.heatpump_heatingpumpmod +HP Module,heatpump,252,hpcompspd,compressor speed,uint8 (>=0<=100),%,false,sensor.heatpump_compressor_speed,sensor.heatpump_hpcompspd HP Module,heatpump,252,hybridstrategy,hybrid control strategy,enum [cost optimized\|co2 optimized\|outside temperature alt.\|outside temperature parallel\|heatpump prefered\|boiler only], ,true,select.heatpump_hybrid_control_strategy,select.heatpump_hybridstrategy HP Module,heatpump,252,lownoisemode,low noise mode,enum [off\|reduced output\|switch off hp\|perm. reduced], ,true,select.heatpump_low_noise_mode,select.heatpump_lownoisemode -HP Module,heatpump,252,lownoisestart,low noise starttime,uint (>=0<=23), ,true,number.heatpump_low_noise_starttime,number.heatpump_lownoisestart -HP Module,heatpump,252,lownoisestop,low noise stoptime,uint (>=0<=23), ,true,number.heatpump_low_noise_stoptime,number.heatpump_lownoisestop +HP Module,heatpump,252,lownoisestart,low noise starttime,uint8 (>=0<=23), ,true,number.heatpump_low_noise_starttime,number.heatpump_lownoisestart +HP Module,heatpump,252,lownoisestop,low noise stoptime,uint8 (>=0<=23), ,true,number.heatpump_low_noise_stoptime,number.heatpump_lownoisestop HP Module,heatpump,252,hybriddhw,hybrid DHW,enum [eco\|high comfort], ,true,select.heatpump_hybrid_DHW,select.heatpump_hybriddhw -HP Module,heatpump,252,energypricegas,energy price gas,uint (>=0<=254), ,true,number.heatpump_energy_price_gas,number.heatpump_energypricegas -HP Module,heatpump,252,energypriceel,energy price electric,uint (>=0<=254), ,true,number.heatpump_energy_price_electric,number.heatpump_energypriceel -HP Module,heatpump,252,energyfeedpv,feed in PV,uint (>=0<=254), ,true,number.heatpump_feed_in_PV,number.heatpump_energyfeedpv -HP Module,heatpump,252,switchovertemp,outside switchover temperature,int (>=-126<=126), ,true,number.heatpump_outside_switchover_temperature,number.heatpump_switchovertemp +HP Module,heatpump,252,energypricegas,energy price gas,uint8 (>=0<=254), ,true,number.heatpump_energy_price_gas,number.heatpump_energypricegas +HP Module,heatpump,252,energypriceel,energy price electric,uint8 (>=0<=254), ,true,number.heatpump_energy_price_electric,number.heatpump_energypriceel +HP Module,heatpump,252,energyfeedpv,feed in PV,uint8 (>=0<=254), ,true,number.heatpump_feed_in_PV,number.heatpump_energyfeedpv +HP Module,heatpump,252,switchovertemp,outside switchover temperature,int8 (>=-126<=126), ,true,number.heatpump_outside_switchover_temperature,number.heatpump_switchovertemp HP Module,heatpump,252,airpurgemode,air purge mode,boolean, ,true,switch.heatpump_air_purge_mode,switch.heatpump_airpurgemode -HP Module,heatpump,252,heatpumpoutput,heatpump output,uint (>=0<=100),%,true,number.heatpump_heatpump_output,number.heatpump_heatpumpoutput +HP Module,heatpump,252,heatpumpoutput,heatpump output,uint8 (>=0<=100),%,true,number.heatpump_heatpump_output,number.heatpump_heatpumpoutput HP Module,heatpump,252,coolingcircuit,cooling circuit,boolean, ,true,switch.heatpump_cooling_circuit,switch.heatpump_coolingcircuit -HP Module,heatpump,252,compstartmod,compressor start modulation,uint (>=0<=100),%,true,number.heatpump_compressor_start_modulation,number.heatpump_compstartmod +HP Module,heatpump,252,compstartmod,compressor start modulation,uint8 (>=0<=100),%,true,number.heatpump_compressor_start_modulation,number.heatpump_compstartmod HP Module,heatpump,252,heatdrainpan,heat drain pan,boolean, ,true,switch.heatpump_heat_drain_pan,switch.heatpump_heatdrainpan HP Module,heatpump,252,heatcable,heating cable,boolean, ,true,switch.heatpump_heating_cable,switch.heatpump_heatcable -HP Module,heatpump,252,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.heatpump_total_energy,sensor.heatpump_nrgtotal -HP Module,heatpump,252,nrgww,energy,ulong (>=0<=167772),kWh,false,sensor.heatpump_energy,sensor.heatpump_nrgww -HP Module,heatpump,252,nrgheat,energy heating,ulong (>=0<=167772),kWh,false,sensor.heatpump_energy_heating,sensor.heatpump_nrgheat -HP Module,heatpump,252,metertotal,meter total,ulong (>=0<=167772),kWh,false,sensor.heatpump_meter_total,sensor.heatpump_metertotal -HP Module,heatpump,252,metercomp,meter compressor,ulong (>=0<=167772),kWh,false,sensor.heatpump_meter_compressor,sensor.heatpump_metercomp -HP Module,heatpump,252,metereheat,meter e-heater,ulong (>=0<=167772),kWh,false,sensor.heatpump_meter_e-heater,sensor.heatpump_metereheat -HP Module,heatpump,252,meterheat,meter heating,ulong (>=0<=167772),kWh,false,sensor.heatpump_meter_heating,sensor.heatpump_meterheat -HP Module,heatpump,252,meterww,meter,ulong (>=0<=167772),kWh,false,sensor.heatpump_meter,sensor.heatpump_meterww -Hybrid Manager HM200,heatpump,248,airhumidity,relative air humidity,uint (>=0<=100),%,false,sensor.heatpump_relative_air_humidity,sensor.heatpump_airhumidity -Hybrid Manager HM200,heatpump,248,dewtemperature,dew point temperature,uint (>=0<=254),C,false,sensor.heatpump_dew_point_temperature,sensor.heatpump_dewtemperature -Hybrid Manager HM200,heatpump,248,curflowtemp,current flow temperature,short (>=-3199<=3199),C,false,sensor.heatpump_current_flow_temperature,sensor.heatpump_curflowtemp -Hybrid Manager HM200,heatpump,248,rettemp,return temperature,short (>=-3199<=3199),C,false,sensor.heatpump_return_temperature,sensor.heatpump_rettemp -Hybrid Manager HM200,heatpump,248,sysrettemp,system return temperature,short (>=-3199<=3199),C,false,sensor.heatpump_system_return_temperature,sensor.heatpump_sysrettemp -Hybrid Manager HM200,heatpump,248,hpta4,drain pan temp (TA4),short (>=-3199<=3199),C,false,sensor.heatpump_drain_pan_temp_(TA4),sensor.heatpump_hpta4 -Hybrid Manager HM200,heatpump,248,hptr1,compressor temperature (TR1),short (>=-3199<=3199),C,false,sensor.heatpump_compressor_temperature_(TR1),sensor.heatpump_hptr1 -Hybrid Manager HM200,heatpump,248,hptr3,refrigerant temperature liquid side (condenser output) (TR3),short (>=-3199<=3199),C,false,sensor.heatpump_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.heatpump_hptr3 -Hybrid Manager HM200,heatpump,248,hptr4,evaporator inlet temperature (TR4),short (>=-3199<=3199),C,false,sensor.heatpump_evaporator_inlet_temperature_(TR4),sensor.heatpump_hptr4 -Hybrid Manager HM200,heatpump,248,hptr5,compressor inlet temperature (TR5),short (>=-3199<=3199),C,false,sensor.heatpump_compressor_inlet_temperature_(TR5),sensor.heatpump_hptr5 -Hybrid Manager HM200,heatpump,248,hptr6,compressor outlet temperature (TR6),short (>=-3199<=3199),C,false,sensor.heatpump_compressor_outlet_temperature_(TR6),sensor.heatpump_hptr6 -Hybrid Manager HM200,heatpump,248,hptl2,air inlet temperature (TL2),short (>=-3199<=3199),C,false,sensor.heatpump_air_inlet_temperature_(TL2),sensor.heatpump_hptl2 -Hybrid Manager HM200,heatpump,248,hppl1,low pressure side temperature (PL1),short (>=-3199<=3199),C,false,sensor.heatpump_low_pressure_side_temperature_(PL1),sensor.heatpump_hppl1 -Hybrid Manager HM200,heatpump,248,hpph1,high pressure side temperature (PH1),short (>=-3199<=3199),C,false,sensor.heatpump_high_pressure_side_temperature_(PH1),sensor.heatpump_hpph1 -Hybrid Manager HM200,heatpump,248,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.heatpump_heating_pump_modulation,sensor.heatpump_heatingpumpmod -Hybrid Manager HM200,heatpump,248,hpcompspd,compressor speed,uint (>=0<=100),%,false,sensor.heatpump_compressor_speed,sensor.heatpump_hpcompspd +HP Module,heatpump,252,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.heatpump_total_energy,sensor.heatpump_nrgtotal +HP Module,heatpump,252,nrgdhw,energy,uint24 (>=0<=167772),kWh,false,sensor.heatpump_dhw_energy,sensor.heatpump_dhw_nrgdhw +HP Module,heatpump,252,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_energy_heating,sensor.heatpump_nrgheat +HP Module,heatpump,252,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_total,sensor.heatpump_metertotal +HP Module,heatpump,252,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_compressor,sensor.heatpump_metercomp +HP Module,heatpump,252,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_e-heater,sensor.heatpump_metereheat +HP Module,heatpump,252,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_heating,sensor.heatpump_meterheat +HP Module,heatpump,252,meterdhw,meter,uint24 (>=0<=167772),kWh,false,sensor.heatpump_dhw_meter,sensor.heatpump_dhw_meterdhw +Hybrid Manager HM200,heatpump,248,airhumidity,relative air humidity,uint8 (>=0<=100),%,false,sensor.heatpump_relative_air_humidity,sensor.heatpump_airhumidity +Hybrid Manager HM200,heatpump,248,dewtemperature,dew point temperature,uint8 (>=0<=254),C,false,sensor.heatpump_dew_point_temperature,sensor.heatpump_dewtemperature +Hybrid Manager HM200,heatpump,248,curflowtemp,current flow temperature,int16 (>=-3199<=3199),C,false,sensor.heatpump_current_flow_temperature,sensor.heatpump_curflowtemp +Hybrid Manager HM200,heatpump,248,rettemp,return temperature,int16 (>=-3199<=3199),C,false,sensor.heatpump_return_temperature,sensor.heatpump_rettemp +Hybrid Manager HM200,heatpump,248,sysrettemp,system return temperature,int16 (>=-3199<=3199),C,false,sensor.heatpump_system_return_temperature,sensor.heatpump_sysrettemp +Hybrid Manager HM200,heatpump,248,hpta4,drain pan temp (TA4),int16 (>=-3199<=3199),C,false,sensor.heatpump_drain_pan_temp_(TA4),sensor.heatpump_hpta4 +Hybrid Manager HM200,heatpump,248,hptr1,compressor temperature (TR1),int16 (>=-3199<=3199),C,false,sensor.heatpump_compressor_temperature_(TR1),sensor.heatpump_hptr1 +Hybrid Manager HM200,heatpump,248,hptr3,refrigerant temperature liquid side (condenser output) (TR3),int16 (>=-3199<=3199),C,false,sensor.heatpump_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.heatpump_hptr3 +Hybrid Manager HM200,heatpump,248,hptr4,evaporator inlet temperature (TR4),int16 (>=-3199<=3199),C,false,sensor.heatpump_evaporator_inlet_temperature_(TR4),sensor.heatpump_hptr4 +Hybrid Manager HM200,heatpump,248,hptr5,compressor inlet temperature (TR5),int16 (>=-3199<=3199),C,false,sensor.heatpump_compressor_inlet_temperature_(TR5),sensor.heatpump_hptr5 +Hybrid Manager HM200,heatpump,248,hptr6,compressor outlet temperature (TR6),int16 (>=-3199<=3199),C,false,sensor.heatpump_compressor_outlet_temperature_(TR6),sensor.heatpump_hptr6 +Hybrid Manager HM200,heatpump,248,hptl2,air inlet temperature (TL2),int16 (>=-3199<=3199),C,false,sensor.heatpump_air_inlet_temperature_(TL2),sensor.heatpump_hptl2 +Hybrid Manager HM200,heatpump,248,hppl1,low pressure side temperature (PL1),int16 (>=-3199<=3199),C,false,sensor.heatpump_low_pressure_side_temperature_(PL1),sensor.heatpump_hppl1 +Hybrid Manager HM200,heatpump,248,hpph1,high pressure side temperature (PH1),int16 (>=-3199<=3199),C,false,sensor.heatpump_high_pressure_side_temperature_(PH1),sensor.heatpump_hpph1 +Hybrid Manager HM200,heatpump,248,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.heatpump_heating_pump_modulation,sensor.heatpump_heatingpumpmod +Hybrid Manager HM200,heatpump,248,hpcompspd,compressor speed,uint8 (>=0<=100),%,false,sensor.heatpump_compressor_speed,sensor.heatpump_hpcompspd Hybrid Manager HM200,heatpump,248,hybridstrategy,hybrid control strategy,enum [cost optimized\|co2 optimized\|outside temperature alt.\|outside temperature parallel\|heatpump prefered\|boiler only], ,true,select.heatpump_hybrid_control_strategy,select.heatpump_hybridstrategy Hybrid Manager HM200,heatpump,248,lownoisemode,low noise mode,enum [off\|reduced output\|switch off hp\|perm. reduced], ,true,select.heatpump_low_noise_mode,select.heatpump_lownoisemode -Hybrid Manager HM200,heatpump,248,lownoisestart,low noise starttime,uint (>=0<=23), ,true,number.heatpump_low_noise_starttime,number.heatpump_lownoisestart -Hybrid Manager HM200,heatpump,248,lownoisestop,low noise stoptime,uint (>=0<=23), ,true,number.heatpump_low_noise_stoptime,number.heatpump_lownoisestop +Hybrid Manager HM200,heatpump,248,lownoisestart,low noise starttime,uint8 (>=0<=23), ,true,number.heatpump_low_noise_starttime,number.heatpump_lownoisestart +Hybrid Manager HM200,heatpump,248,lownoisestop,low noise stoptime,uint8 (>=0<=23), ,true,number.heatpump_low_noise_stoptime,number.heatpump_lownoisestop Hybrid Manager HM200,heatpump,248,hybriddhw,hybrid DHW,enum [eco\|high comfort], ,true,select.heatpump_hybrid_DHW,select.heatpump_hybriddhw -Hybrid Manager HM200,heatpump,248,energypricegas,energy price gas,uint (>=0<=254), ,true,number.heatpump_energy_price_gas,number.heatpump_energypricegas -Hybrid Manager HM200,heatpump,248,energypriceel,energy price electric,uint (>=0<=254), ,true,number.heatpump_energy_price_electric,number.heatpump_energypriceel -Hybrid Manager HM200,heatpump,248,energyfeedpv,feed in PV,uint (>=0<=254), ,true,number.heatpump_feed_in_PV,number.heatpump_energyfeedpv -Hybrid Manager HM200,heatpump,248,switchovertemp,outside switchover temperature,int (>=-126<=126), ,true,number.heatpump_outside_switchover_temperature,number.heatpump_switchovertemp +Hybrid Manager HM200,heatpump,248,energypricegas,energy price gas,uint8 (>=0<=254), ,true,number.heatpump_energy_price_gas,number.heatpump_energypricegas +Hybrid Manager HM200,heatpump,248,energypriceel,energy price electric,uint8 (>=0<=254), ,true,number.heatpump_energy_price_electric,number.heatpump_energypriceel +Hybrid Manager HM200,heatpump,248,energyfeedpv,feed in PV,uint8 (>=0<=254), ,true,number.heatpump_feed_in_PV,number.heatpump_energyfeedpv +Hybrid Manager HM200,heatpump,248,switchovertemp,outside switchover temperature,int8 (>=-126<=126), ,true,number.heatpump_outside_switchover_temperature,number.heatpump_switchovertemp Hybrid Manager HM200,heatpump,248,airpurgemode,air purge mode,boolean, ,true,switch.heatpump_air_purge_mode,switch.heatpump_airpurgemode -Hybrid Manager HM200,heatpump,248,heatpumpoutput,heatpump output,uint (>=0<=100),%,true,number.heatpump_heatpump_output,number.heatpump_heatpumpoutput +Hybrid Manager HM200,heatpump,248,heatpumpoutput,heatpump output,uint8 (>=0<=100),%,true,number.heatpump_heatpump_output,number.heatpump_heatpumpoutput Hybrid Manager HM200,heatpump,248,coolingcircuit,cooling circuit,boolean, ,true,switch.heatpump_cooling_circuit,switch.heatpump_coolingcircuit -Hybrid Manager HM200,heatpump,248,compstartmod,compressor start modulation,uint (>=0<=100),%,true,number.heatpump_compressor_start_modulation,number.heatpump_compstartmod +Hybrid Manager HM200,heatpump,248,compstartmod,compressor start modulation,uint8 (>=0<=100),%,true,number.heatpump_compressor_start_modulation,number.heatpump_compstartmod Hybrid Manager HM200,heatpump,248,heatdrainpan,heat drain pan,boolean, ,true,switch.heatpump_heat_drain_pan,switch.heatpump_heatdrainpan Hybrid Manager HM200,heatpump,248,heatcable,heating cable,boolean, ,true,switch.heatpump_heating_cable,switch.heatpump_heatcable -Hybrid Manager HM200,heatpump,248,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.heatpump_total_energy,sensor.heatpump_nrgtotal -Hybrid Manager HM200,heatpump,248,nrgww,energy,ulong (>=0<=167772),kWh,false,sensor.heatpump_energy,sensor.heatpump_nrgww -Hybrid Manager HM200,heatpump,248,nrgheat,energy heating,ulong (>=0<=167772),kWh,false,sensor.heatpump_energy_heating,sensor.heatpump_nrgheat -Hybrid Manager HM200,heatpump,248,metertotal,meter total,ulong (>=0<=167772),kWh,false,sensor.heatpump_meter_total,sensor.heatpump_metertotal -Hybrid Manager HM200,heatpump,248,metercomp,meter compressor,ulong (>=0<=167772),kWh,false,sensor.heatpump_meter_compressor,sensor.heatpump_metercomp -Hybrid Manager HM200,heatpump,248,metereheat,meter e-heater,ulong (>=0<=167772),kWh,false,sensor.heatpump_meter_e-heater,sensor.heatpump_metereheat -Hybrid Manager HM200,heatpump,248,meterheat,meter heating,ulong (>=0<=167772),kWh,false,sensor.heatpump_meter_heating,sensor.heatpump_meterheat -Hybrid Manager HM200,heatpump,248,meterww,meter,ulong (>=0<=167772),kWh,false,sensor.heatpump_meter,sensor.heatpump_meterww +Hybrid Manager HM200,heatpump,248,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.heatpump_total_energy,sensor.heatpump_nrgtotal +Hybrid Manager HM200,heatpump,248,nrgdhw,energy,uint24 (>=0<=167772),kWh,false,sensor.heatpump_dhw_energy,sensor.heatpump_dhw_nrgdhw +Hybrid Manager HM200,heatpump,248,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_energy_heating,sensor.heatpump_nrgheat +Hybrid Manager HM200,heatpump,248,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_total,sensor.heatpump_metertotal +Hybrid Manager HM200,heatpump,248,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_compressor,sensor.heatpump_metercomp +Hybrid Manager HM200,heatpump,248,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_e-heater,sensor.heatpump_metereheat +Hybrid Manager HM200,heatpump,248,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_heating,sensor.heatpump_meterheat +Hybrid Manager HM200,heatpump,248,meterdhw,meter,uint24 (>=0<=167772),kWh,false,sensor.heatpump_dhw_meter,sensor.heatpump_dhw_meterdhw WM10,switch,71,activated,activated,boolean, ,false,binary_sensor.switch_activated,binary_sensor.switch_activated -WM10,switch,71,flowtemphc,flow temperature (TC1),ushort (>=0<=3199),C,false,sensor.switch_flow_temperature_(TC1),sensor.switch_flowtemphc -WM10,switch,71,status,status,int (>=-126<=126), ,false,sensor.switch_status,sensor.switch_status +WM10,switch,71,flowtemphc,flow temperature (TC1),uint16 (>=0<=3199),C,false,sensor.switch_flow_temperature_(TC1),sensor.switch_flowtemphc +WM10,switch,71,status,status,int8 (>=-126<=126), ,false,sensor.switch_status,sensor.switch_status Rego 3000,controller,240,datetime,date/time,string, ,false,sensor.controller_date/time,sensor.controller_datetime -EM10,alert,74,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.alert_set_flow_temperature,sensor.alert_setflowtemp -EM10,alert,74,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.alert_burner_set_power,sensor.alert_setburnpow -EM10/EM100,extension,243,flowtempvf,flow temperature in header (T0/Vf),short (>=-3199<=3199),C,false,sensor.extension_flow_temperature_in_header_(T0/Vf),sensor.extension_flowtempvf -EM10/EM100,extension,243,input,input,uint (>=0<=25),V,false,sensor.extension_input,sensor.extension_input -EM10/EM100,extension,243,outpow,output IO1,uint (>=0<=100),%,false,sensor.extension_output_IO1,sensor.extension_outpow -EM10/EM100,extension,243,setpower,request power,uint (>=0<=100),%,false,sensor.extension_request_power,sensor.extension_setpower -EM10/EM100,extension,243,setpoint,set temp.,uint (>=0<=254),C,false,sensor.extension_set_temp.,sensor.extension_setpoint -EM10/EM100,extension,243,minv,min volt.,uint (>=0<=25),V,true,number.extension_min_volt.,number.extension_minv -EM10/EM100,extension,243,maxv,max volt.,uint (>=0<=25),V,true,number.extension_max_volt.,number.extension_maxv -EM10/EM100,extension,243,mint,min temp.,uint (>=0<=254),C,true,number.extension_min_temp.,number.extension_mint -EM10/EM100,extension,243,maxt,max temp.,uint (>=0<=254),C,true,number.extension_max_temp.,number.extension_maxt -EM10/EM100,extension,243,mode,mode,uint (>=0<=254), ,false,sensor.extension_mode,sensor.extension_mode -T1RF,extension,220,flowtempvf,flow temperature in header (T0/Vf),short (>=-3199<=3199),C,false,sensor.extension_flow_temperature_in_header_(T0/Vf),sensor.extension_flowtempvf -T1RF,extension,220,input,input,uint (>=0<=25),V,false,sensor.extension_input,sensor.extension_input -T1RF,extension,220,outpow,output IO1,uint (>=0<=100),%,false,sensor.extension_output_IO1,sensor.extension_outpow -T1RF,extension,220,setpower,request power,uint (>=0<=100),%,false,sensor.extension_request_power,sensor.extension_setpower -T1RF,extension,220,setpoint,set temp.,uint (>=0<=254),C,false,sensor.extension_set_temp.,sensor.extension_setpoint -T1RF,extension,220,minv,min volt.,uint (>=0<=25),V,true,number.extension_min_volt.,number.extension_minv -T1RF,extension,220,maxv,max volt.,uint (>=0<=25),V,true,number.extension_max_volt.,number.extension_maxv -T1RF,extension,220,mint,min temp.,uint (>=0<=254),C,true,number.extension_min_temp.,number.extension_mint -T1RF,extension,220,maxt,max temp.,uint (>=0<=254),C,true,number.extension_max_temp.,number.extension_maxt -T1RF,extension,220,mode,mode,uint (>=0<=254), ,false,sensor.extension_mode,sensor.extension_mode -Logavent HRV176,ventilation,231,outfresh,outdoor fresh air,short (>=-3199<=3199),C,false,sensor.ventilation_outdoor_fresh_air,sensor.ventilation_outfresh -Logavent HRV176,ventilation,231,infresh,indoor fresh air,short (>=-3199<=3199),C,false,sensor.ventilation_indoor_fresh_air,sensor.ventilation_infresh -Logavent HRV176,ventilation,231,outexhaust,outdoor exhaust air,short (>=-3199<=3199),C,false,sensor.ventilation_outdoor_exhaust_air,sensor.ventilation_outexhaust -Logavent HRV176,ventilation,231,inexhaust,indoor exhaust air,short (>=-3199<=3199),C,false,sensor.ventilation_indoor_exhaust_air,sensor.ventilation_inexhaust -Logavent HRV176,ventilation,231,ventinspeed,in blower speed,uint (>=0<=100),%,false,sensor.ventilation_in_blower_speed,sensor.ventilation_ventinspeed -Logavent HRV176,ventilation,231,ventoutspeed,out blower speed,uint (>=0<=100),%,false,sensor.ventilation_out_blower_speed,sensor.ventilation_ventoutspeed +EM10,alert,74,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.alert_set_flow_temperature,sensor.alert_setflowtemp +EM10,alert,74,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.alert_burner_set_power,sensor.alert_setburnpow +EM10/EM100,extension,243,flowtempvf,flow temperature in header (T0/Vf),int16 (>=-3199<=3199),C,false,sensor.extension_flow_temperature_in_header_(T0/Vf),sensor.extension_flowtempvf +EM10/EM100,extension,243,input,input,uint8 (>=0<=25),V,false,sensor.extension_input,sensor.extension_input +EM10/EM100,extension,243,outpow,output IO1,uint8 (>=0<=100),%,false,sensor.extension_output_IO1,sensor.extension_outpow +EM10/EM100,extension,243,setpower,request power,uint8 (>=0<=100),%,false,sensor.extension_request_power,sensor.extension_setpower +EM10/EM100,extension,243,setpoint,set temp.,uint8 (>=0<=254),C,false,sensor.extension_set_temp.,sensor.extension_setpoint +EM10/EM100,extension,243,minv,min volt.,uint8 (>=0<=25),V,true,number.extension_min_volt.,number.extension_minv +EM10/EM100,extension,243,maxv,max volt.,uint8 (>=0<=25),V,true,number.extension_max_volt.,number.extension_maxv +EM10/EM100,extension,243,mint,min temp.,uint8 (>=0<=254),C,true,number.extension_min_temp.,number.extension_mint +EM10/EM100,extension,243,maxt,max temp.,uint8 (>=0<=254),C,true,number.extension_max_temp.,number.extension_maxt +EM10/EM100,extension,243,mode,mode,uint8 (>=0<=254), ,false,sensor.extension_mode,sensor.extension_mode +T1RF,extension,220,flowtempvf,flow temperature in header (T0/Vf),int16 (>=-3199<=3199),C,false,sensor.extension_flow_temperature_in_header_(T0/Vf),sensor.extension_flowtempvf +T1RF,extension,220,input,input,uint8 (>=0<=25),V,false,sensor.extension_input,sensor.extension_input +T1RF,extension,220,outpow,output IO1,uint8 (>=0<=100),%,false,sensor.extension_output_IO1,sensor.extension_outpow +T1RF,extension,220,setpower,request power,uint8 (>=0<=100),%,false,sensor.extension_request_power,sensor.extension_setpower +T1RF,extension,220,setpoint,set temp.,uint8 (>=0<=254),C,false,sensor.extension_set_temp.,sensor.extension_setpoint +T1RF,extension,220,minv,min volt.,uint8 (>=0<=25),V,true,number.extension_min_volt.,number.extension_minv +T1RF,extension,220,maxv,max volt.,uint8 (>=0<=25),V,true,number.extension_max_volt.,number.extension_maxv +T1RF,extension,220,mint,min temp.,uint8 (>=0<=254),C,true,number.extension_min_temp.,number.extension_mint +T1RF,extension,220,maxt,max temp.,uint8 (>=0<=254),C,true,number.extension_max_temp.,number.extension_maxt +T1RF,extension,220,mode,mode,uint8 (>=0<=254), ,false,sensor.extension_mode,sensor.extension_mode +Logavent HRV176,ventilation,231,outfresh,outdoor fresh air,int16 (>=-3199<=3199),C,false,sensor.ventilation_outdoor_fresh_air,sensor.ventilation_outfresh +Logavent HRV176,ventilation,231,infresh,indoor fresh air,int16 (>=-3199<=3199),C,false,sensor.ventilation_indoor_fresh_air,sensor.ventilation_infresh +Logavent HRV176,ventilation,231,outexhaust,outdoor exhaust air,int16 (>=-3199<=3199),C,false,sensor.ventilation_outdoor_exhaust_air,sensor.ventilation_outexhaust +Logavent HRV176,ventilation,231,inexhaust,indoor exhaust air,int16 (>=-3199<=3199),C,false,sensor.ventilation_indoor_exhaust_air,sensor.ventilation_inexhaust +Logavent HRV176,ventilation,231,ventinspeed,in blower speed,uint8 (>=0<=100),%,false,sensor.ventilation_in_blower_speed,sensor.ventilation_ventinspeed +Logavent HRV176,ventilation,231,ventoutspeed,out blower speed,uint8 (>=0<=100),%,false,sensor.ventilation_out_blower_speed,sensor.ventilation_ventoutspeed Logavent HRV176,ventilation,231,ventmode,ventilation mode,enum [auto\|off\|L1\|L2\|L3\|L4\|demand\|sleep\|intense\|bypass\|party\|fireplace], ,true,select.ventilation_ventilation_mode,select.ventilation_ventmode -Logavent HRV176,ventilation,231,airquality,air quality (voc),ushort (>=0<=31999), ,false,sensor.ventilation_air_quality_(voc),sensor.ventilation_airquality -Logavent HRV176,ventilation,231,airhumidity,relative air humidity,uint (>=0<=100),%,false,sensor.ventilation_relative_air_humidity,sensor.ventilation_airhumidity -MP100,pool,204,pooltemp,pool temperature,short (>=-3199<=3199),C,false,sensor.pool_pool_temperature,sensor.pool_pooltemp +Logavent HRV176,ventilation,231,airquality,air quality (voc),uint16 (>=0<=31999), ,false,sensor.ventilation_air_quality_(voc),sensor.ventilation_airquality +Logavent HRV176,ventilation,231,airhumidity,relative air humidity,uint8 (>=0<=100),%,false,sensor.ventilation_relative_air_humidity,sensor.ventilation_airhumidity +MP100,pool,204,pooltemp,pool temperature,int16 (>=-3199<=3199),C,false,sensor.pool_pool_temperature,sensor.pool_pooltemp MP100,pool,204,poolshuntstatus,pool shunt status opening/closing,enum [stopped\|opening\|closing\|open\|close], ,false,sensor.pool_pool_shunt_status_opening/closing,sensor.pool_poolshuntstatus -MP100,pool,204,poolshunt,pool shunt open/close (0% = pool / 100% = heat),uint (>=0<=100),%,false,sensor.pool_pool_shunt_open/close_(0%_=_pool_/_100%_=_heat),sensor.pool_poolshunt +MP100,pool,204,poolshunt,pool shunt open/close (0% = pool / 100% = heat),uint8 (>=0<=100),%,false,sensor.pool_pool_shunt_open/close_(0%_=_pool_/_100%_=_heat),sensor.pool_poolshunt