mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-07 16:29:51 +03:00
added more Junkers devices
This commit is contained in:
13
src/ems.cpp
13
src/ems.cpp
@@ -187,8 +187,8 @@ const _EMS_Type EMS_Types[] = {
|
||||
{EMS_MODEL_ALL, EMS_TYPE_JunkersStatusMessage, "JunkersStatusMessage", _process_JunkersStatusMessage},
|
||||
|
||||
// Mixing devices
|
||||
{EMS_MODEL_MM100, EMS_TYPE_MMPLUSStatusMessage_HC1, "MMPLUSStatusMessage_HC1", _process_MMPLUSStatusMessage},
|
||||
{EMS_MODEL_MM100, EMS_TYPE_MMPLUSStatusMessage_HC2, "MMPLUSStatusMessage_HC2", _process_MMPLUSStatusMessage},
|
||||
{EMS_MODEL_MM, EMS_TYPE_MMPLUSStatusMessage_HC1, "MMPLUSStatusMessage_HC1", _process_MMPLUSStatusMessage},
|
||||
{EMS_MODEL_MM, EMS_TYPE_MMPLUSStatusMessage_HC2, "MMPLUSStatusMessage_HC2", _process_MMPLUSStatusMessage},
|
||||
|
||||
};
|
||||
|
||||
@@ -2521,8 +2521,10 @@ void ems_scanDevices() {
|
||||
|
||||
std::list<uint8_t> Device_Ids; // create a new list
|
||||
|
||||
// add boiler device_id which is always 0x08
|
||||
Device_Ids.push_back(EMS_ID_BOILER);
|
||||
|
||||
Device_Ids.push_back(EMS_ID_BOILER); // add boiler device_id which is always 0x08
|
||||
Device_Ids.push_back(EMS_ID_HP); // add heat pump
|
||||
Device_Ids.push_back(EMS_ID_SM); // add solar module
|
||||
|
||||
// copy over thermostats
|
||||
for (_Thermostat_Device tt : Thermostat_Devices) {
|
||||
@@ -2534,9 +2536,6 @@ void ems_scanDevices() {
|
||||
Device_Ids.push_back(ot.device_id);
|
||||
}
|
||||
|
||||
Device_Ids.push_back(EMS_ID_HP); // add heat pump
|
||||
Device_Ids.push_back(EMS_ID_SM); // add solar module
|
||||
|
||||
// remove duplicates and reserved IDs (like our own device)
|
||||
Device_Ids.sort();
|
||||
Device_Ids.unique();
|
||||
|
||||
@@ -160,16 +160,12 @@ typedef enum {
|
||||
EMS_MODEL_NONE, // unset
|
||||
EMS_MODEL_ALL, // common for all devices
|
||||
|
||||
// heatpump
|
||||
EMS_MODEL_HP,
|
||||
EMS_MODEL_HP, // heatpump
|
||||
EMS_MODEL_SM, // solar module
|
||||
EMS_MODEL_MM, // mixer module
|
||||
EMS_MODEL_UBA, // boiler
|
||||
|
||||
// solar module
|
||||
EMS_MODEL_SM,
|
||||
|
||||
// boiler
|
||||
EMS_MODEL_UBA,
|
||||
|
||||
// and the thermostats
|
||||
// and the various thermostats
|
||||
EMS_MODEL_ES73,
|
||||
EMS_MODEL_RC10,
|
||||
EMS_MODEL_RC20,
|
||||
@@ -187,9 +183,8 @@ typedef enum {
|
||||
EMS_MODEL_FR100,
|
||||
EMS_MODEL_FR110,
|
||||
EMS_MODEL_FW120,
|
||||
|
||||
// mixing devices
|
||||
EMS_MODEL_MM100
|
||||
EMS_MODEL_FW200,
|
||||
EMS_MODEL_FR120
|
||||
|
||||
} _EMS_MODEL_ID;
|
||||
|
||||
@@ -235,7 +230,10 @@ const _Mixing_Device Mixing_Devices[] = {
|
||||
{160, "MM100 Mixing Module"},
|
||||
{161, "MM200 Mixing Module"},
|
||||
{69, "MM10 Mixer Module"},
|
||||
{159, "MM50 Mixing Module"}
|
||||
{159, "MM50 Mixing Module"},
|
||||
{79, "MM100 Mixer Module"},
|
||||
{80, "MM200 Mixer Module"},
|
||||
{78, "MM400 Mixer Module"}
|
||||
|
||||
};
|
||||
|
||||
@@ -251,7 +249,7 @@ const _Other_Device Other_Devices[] = {
|
||||
{125, 0x09, "BC25 Base Controller"},
|
||||
{169, 0x09, "BC40 Base Controller"},
|
||||
{152, 0x09, "Junkers Controller"},
|
||||
{95, 0x09, "Junkers Controller"},
|
||||
{95, 0x09, "Junkers HT3 Controller"},
|
||||
{230, 0x09, "BC Base Controller"},
|
||||
|
||||
{205, 0x02, "Nefit Moduline Easy Connect"},
|
||||
@@ -274,6 +272,7 @@ const _HeatPump_Device HeatPump_Devices[] = {
|
||||
/*
|
||||
* Known thermostat types and their capabilities
|
||||
* format is MODEL_ID, PRODUCT ID, DEVICE ID, DESCRIPTION
|
||||
* Typically on DeviceID 0x10 or 0x18
|
||||
*/
|
||||
const _Thermostat_Device Thermostat_Devices[] = {
|
||||
|
||||
@@ -297,9 +296,11 @@ const _Thermostat_Device Thermostat_Devices[] = {
|
||||
|
||||
// Junkers
|
||||
{EMS_MODEL_FW100, 105, 0x10, "Junkers FW100", EMS_THERMOSTAT_WRITE_NO},
|
||||
{EMS_MODEL_FR10, 111, 0x18, "Junkers FR10", EMS_THERMOSTAT_WRITE_NO},
|
||||
{EMS_MODEL_FR100, 105, 0x18, "Junkers FR100", EMS_THERMOSTAT_WRITE_NO},
|
||||
{EMS_MODEL_FW200, 106, 0x10, "Junkers FW200", EMS_THERMOSTAT_WRITE_NO},
|
||||
{EMS_MODEL_FR100, 107, 0x18, "Junkers FR100", EMS_THERMOSTAT_WRITE_NO},
|
||||
{EMS_MODEL_FR110, 108, 0x18, "Junkers FR110", EMS_THERMOSTAT_WRITE_NO},
|
||||
{EMS_MODEL_FR10, 111, 0x18, "Junkers FR10", EMS_THERMOSTAT_WRITE_NO},
|
||||
{EMS_MODEL_FR120, 191, 0x10, "Junkers FR120", EMS_THERMOSTAT_WRITE_NO},
|
||||
{EMS_MODEL_FW120, 192, 0x10, "Junkers FW120", EMS_THERMOSTAT_WRITE_NO},
|
||||
{EMS_MODEL_FR50, 147, 0x10, "Junkers FR50", EMS_THERMOSTAT_WRITE_NO}
|
||||
|
||||
|
||||