FW100 & ISM1 fixed wrong temperature divider

This commit is contained in:
Vuego123
2019-06-11 00:43:27 +02:00
parent 68091b8042
commit c3ab74862d

View File

@@ -479,11 +479,17 @@ void showInfo() {
myDebug_P(PSTR(" Thermostat: %s"), ems_getThermostatDescription(buffer_type));
// Render Current & Setpoint Room Temperature
if ((ems_getThermostatModel() == EMS_MODEL_EASY) || (ems_getThermostatModel() == EMS_MODEL_FR10) || (ems_getThermostatModel() == EMS_MODEL_FW100)) {
// Temperatures are *10
if ((ems_getThermostatModel() == EMS_MODEL_EASY)) {
// Temperatures are *100
_renderShortValue("Set room temperature", "C", EMS_Thermostat.setpoint_roomTemp, 10); // *100
_renderShortValue("Current room temperature", "C", EMS_Thermostat.curr_roomTemp, 10); // *100
} else {
}
else if ((ems_getThermostatModel() == EMS_MODEL_FR10) || (ems_getThermostatModel() == EMS_MODEL_FW100)) {
// Temperatures are *10
_renderShortValue("Set room temperature", "C", EMS_Thermostat.setpoint_roomTemp, 1); // *10
_renderShortValue("Current room temperature", "C", EMS_Thermostat.curr_roomTemp, 1); // *10
}
else {
// because we store in 2 bytes short, when converting to a single byte we'll loose the negative value if its unset
if (EMS_Thermostat.setpoint_roomTemp <= 0) {
EMS_Thermostat.setpoint_roomTemp = EMS_VALUE_INT_NOTSET;