mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-10 01:39:54 +03:00
wwcomfort1 for UBAParameterWWPlus (RC310)
This commit is contained in:
@@ -393,6 +393,13 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
|
||||
FL_(wwComfort),
|
||||
DeviceValueUOM::NONE,
|
||||
MAKE_CF_CB(set_ww_mode));
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA_WW,
|
||||
&wwComfort1_,
|
||||
DeviceValueType::ENUM,
|
||||
FL_(enum_comfort1),
|
||||
FL_(wwComfort1),
|
||||
DeviceValueUOM::NONE,
|
||||
MAKE_CF_CB(set_ww_mode1));
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA_WW,
|
||||
&wwFlowTempOffset_,
|
||||
DeviceValueType::UINT,
|
||||
@@ -781,6 +788,19 @@ void Boiler::process_UBAParameterWWPlus(std::shared_ptr<const Telegram> telegram
|
||||
has_update(telegram, wwDisinfectionTemp_, 12); // setting here, status in E9
|
||||
has_update(telegram, wwSelTempSingle_, 16);
|
||||
has_update(telegram, wwSelTempLow_, 18);
|
||||
|
||||
uint8_t wwComfort1 = EMS_VALUE_UINT_NOTSET;
|
||||
telegram->read_value(wwComfort1, 13);
|
||||
if (wwComfort1 == 0) {
|
||||
wwComfort1 = 0; // High_Comfort
|
||||
} else if (wwComfort1 == 0xD8) {
|
||||
wwComfort1 = 1; // Eco
|
||||
} else {
|
||||
wwComfort1 = EMS_VALUE_UINT_NOTSET;
|
||||
}
|
||||
has_update(wwComfort1_, wwComfort1);
|
||||
|
||||
|
||||
}
|
||||
|
||||
// 0xE9 - WW monitor ems+
|
||||
@@ -1492,6 +1512,31 @@ bool Boiler::set_ww_mode(const char * value, const int8_t id) {
|
||||
return true;
|
||||
}
|
||||
|
||||
// wwcomfort1 for RC310
|
||||
// on a RC310 it's 1=high, 2=eco
|
||||
bool Boiler::set_ww_mode1(const char * value, const int8_t id) {
|
||||
uint8_t set;
|
||||
if (!Helpers::value2enum(value, set, FL_(enum_comfort1))) {
|
||||
return false;
|
||||
}
|
||||
|
||||
if (!is_fetch(EMS_TYPE_UBAParameterWWPlus)) {
|
||||
return false;
|
||||
}
|
||||
|
||||
if (set == 0) {
|
||||
// LOG_INFO(F("Setting boiler dhw to High"));
|
||||
} else if (set == 1) {
|
||||
// LOG_INFO(F("Setting boiler dhw to Eco"));
|
||||
set = 0xD8;
|
||||
} else {
|
||||
return false; // do nothing
|
||||
}
|
||||
|
||||
write_command(EMS_TYPE_UBAParameterWWPlus, 13, set, EMS_TYPE_UBAParameterWWPlus);
|
||||
return true;
|
||||
}
|
||||
|
||||
// turn on/off dhw
|
||||
bool Boiler::set_ww_activated(const char * value, const int8_t id) {
|
||||
bool v = false;
|
||||
|
||||
@@ -58,6 +58,7 @@ class Boiler : public EMSdevice {
|
||||
uint8_t wwSelTempSingle_; // DHW single charge temperature
|
||||
uint8_t wwType_; // 0-off, 1-flow, 2-flowbuffer, 3-buffer, 4-layered buffer
|
||||
uint8_t wwComfort_; // WW comfort mode
|
||||
uint8_t wwComfort1_; // WW comfort mode RC310
|
||||
uint8_t wwCircPump_; // DHW circulation pump available
|
||||
uint8_t wwChargeType_; // DHW charge type (pump or 3-way-valve)
|
||||
uint8_t wwDisinfectionTemp_; // DHW disinfection temperature to prevent infection
|
||||
@@ -240,6 +241,7 @@ class Boiler : public EMSdevice {
|
||||
|
||||
// commands - none of these use the additional id parameter
|
||||
bool set_ww_mode(const char * value, const int8_t id);
|
||||
bool set_ww_mode1(const char * value, const int8_t id);
|
||||
bool set_ww_activated(const char * value, const int8_t id);
|
||||
bool set_tapwarmwater_activated(const char * value, const int8_t id);
|
||||
bool set_ww_onetime(const char * value, const int8_t id);
|
||||
|
||||
Reference in New Issue
Block a user