mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-07 00:09:51 +03:00
update test data for customizations
This commit is contained in:
@@ -473,7 +473,7 @@ const emsesp_devicedata_1 = {
|
|||||||
const emsesp_devicedata_2 = {
|
const emsesp_devicedata_2 = {
|
||||||
label: 'Boiler: Nefit GBx72/Trendline/Cerapur/Greenstar Si/27i',
|
label: 'Boiler: Nefit GBx72/Trendline/Cerapur/Greenstar Si/27i',
|
||||||
data: [
|
data: [
|
||||||
{ v: 0, u: 0, id: '08reset', c: 'reset', l: ['-', 'maintenance', 'error'] },
|
{ v: '', u: 0, id: '08reset', c: 'reset', l: ['-', 'maintenance', 'error'] },
|
||||||
{ v: 'false', u: 0, id: '08heating active' },
|
{ v: 'false', u: 0, id: '08heating active' },
|
||||||
{ v: 'false', u: 0, id: '04tapwater active' },
|
{ v: 'false', u: 0, id: '04tapwater active' },
|
||||||
{ v: 5, u: 1, id: '04selected flow temperature', c: 'selflowtemp' },
|
{ v: 5, u: 1, id: '04selected flow temperature', c: 'selflowtemp' },
|
||||||
@@ -590,6 +590,13 @@ const emsesp_deviceentities_1 = [
|
|||||||
m: 0,
|
m: 0,
|
||||||
w: false,
|
w: false,
|
||||||
},
|
},
|
||||||
|
{
|
||||||
|
v: 'roomTemp',
|
||||||
|
id: 'hc1/HA climate config creation',
|
||||||
|
s: 'hc1/HA climate config creation',
|
||||||
|
m: 0,
|
||||||
|
w: false,
|
||||||
|
},
|
||||||
{
|
{
|
||||||
v: 18.2,
|
v: 18.2,
|
||||||
id: 'hc1 selected room temperature',
|
id: 'hc1 selected room temperature',
|
||||||
@@ -614,10 +621,11 @@ const emsesp_deviceentities_1 = [
|
|||||||
]
|
]
|
||||||
|
|
||||||
const emsesp_deviceentities_2 = [
|
const emsesp_deviceentities_2 = [
|
||||||
{ v: false, id: 'heating active', s: 'heatingactive', m: 0, w: false },
|
{ u: 0, id: 'reset', s: 'reset', m: 8, w: false },
|
||||||
{ v: false, id: 'tapwater active', s: 'tapwateractive', m: 0, w: false },
|
{ v: false, id: 'heating active', s: 'heatingactive', m: 8, w: false },
|
||||||
{ v: 5, id: 'selected flow temperature', s: 'selflowtemp', m: 0, w: true },
|
{ v: false, id: 'tapwater active', s: 'tapwateractive', m: 4, w: false },
|
||||||
{ v: 0, id: 'burner selected max power', s: 'selburnpow', m: 0, w: true },
|
{ v: 5, id: 'selected flow temperature', s: 'selflowtemp', m: 4, w: true },
|
||||||
|
{ v: 0, id: 'burner selected max power', s: 'selburnpow', m: 14, w: true },
|
||||||
{ v: 0, id: 'heating pump modulation', s: 'heatingpumpmod', m: 0, w: false },
|
{ v: 0, id: 'heating pump modulation', s: 'heatingpumpmod', m: 0, w: false },
|
||||||
{ id: 'heating pump 2 modulation', s: 'heatingpump2mod', m: 0, w: false },
|
{ id: 'heating pump 2 modulation', s: 'heatingpump2mod', m: 0, w: false },
|
||||||
{ id: 'outside temperature', s: 'outdoortemp', m: 0, w: false },
|
{ id: 'outside temperature', s: 'outdoortemp', m: 0, w: false },
|
||||||
|
|||||||
Reference in New Issue