From c4dc1cdaaffb107c6f17205c5f534a81723b46e8 Mon Sep 17 00:00:00 2001 From: proddy Date: Sat, 11 May 2019 10:48:16 +0200 Subject: [PATCH] disabled writing to ems+ thermostats until implemented --- src/ems_devices.h | 10 +++++----- 1 file changed, 5 insertions(+), 5 deletions(-) diff --git a/src/ems_devices.h b/src/ems_devices.h index 600db0479..0030a7d83 100644 --- a/src/ems_devices.h +++ b/src/ems_devices.h @@ -194,16 +194,16 @@ const _Thermostat_Type Thermostat_Types[] = { {EMS_MODEL_RC20F, 93, 0x18, "RC20F", EMS_THERMOSTAT_WRITE_YES}, {EMS_MODEL_RC30, 78, 0x10, "RC30/Nefit Moduline 400", EMS_THERMOSTAT_WRITE_YES}, {EMS_MODEL_RC35, 86, 0x10, "RC35", EMS_THERMOSTAT_WRITE_YES}, - {EMS_MODEL_RC310, 158, 0x10, "RC3x0/Nefit Moduline 1010H", EMS_THERMOSTAT_WRITE_YES}, - {EMS_MODEL_1010, 165, 0x18, "Nefit Moduline 1010", EMS_THERMOSTAT_WRITE_YES}, + {EMS_MODEL_RC310, 158, 0x10, "RC3x0/Nefit Moduline 1010H", EMS_THERMOSTAT_WRITE_NO}, + {EMS_MODEL_1010, 165, 0x18, "Nefit Moduline 1010", EMS_THERMOSTAT_WRITE_NO}, // Sieger {EMS_MODEL_ES73, 76, 0x10, "Sieger ES73", EMS_THERMOSTAT_WRITE_YES}, // Junkers - {EMS_MODEL_FR10, 111, 0x18, "Junkers FR10", EMS_THERMOSTAT_WRITE_YES}, - {EMS_MODEL_FR100, 105, 0x18, "Junkers FR100", EMS_THERMOSTAT_WRITE_YES}, - {EMS_MODEL_FR110, 108, 0x18, "Junkers FR110", EMS_THERMOSTAT_WRITE_YES} + {EMS_MODEL_FR10, 111, 0x18, "Junkers FR10", EMS_THERMOSTAT_WRITE_NO}, + {EMS_MODEL_FR100, 105, 0x18, "Junkers FR100", EMS_THERMOSTAT_WRITE_NO}, + {EMS_MODEL_FR110, 108, 0x18, "Junkers FR110", EMS_THERMOSTAT_WRITE_NO} };