RC20RF tap water one time loading function

This commit is contained in:
Christian Weithe
2019-10-28 19:26:29 +01:00
parent 13f86edd8a
commit c62502052d
5 changed files with 41 additions and 1 deletions

View File

@@ -26,6 +26,7 @@
#define EMS_TYPE_UBAMaintenanceStatusMessage 0x1C // is an automatic monitor broadcast
#define EMS_TYPE_UBAParameterWW 0x33
#define EMS_TYPE_UBATotalUptimeMessage 0x14
#define EMS_TYPE_UBAFlags 0x35
#define EMS_TYPE_UBAMaintenanceSettingsMessage 0x15
#define EMS_TYPE_UBAParametersMessage 0x16
#define EMS_TYPE_UBASetPoints 0x1A
@@ -33,6 +34,7 @@
#define EMS_OFFSET_UBAParameterWW_wwtemp 2 // WW Temperature
#define EMS_OFFSET_UBAParameterWW_wwactivated 1 // WW Activated
#define EMS_OFFSET_UBAParameterWW_wwOneTime 5 // WW OneTime loading
#define EMS_OFFSET_UBAParameterWW_wwComfort 9 // WW is in comfort or eco mode
#define EMS_VALUE_UBAParameterWW_wwComfort_Hot 0x00 // the value for hot
#define EMS_VALUE_UBAParameterWW_wwComfort_Eco 0xD8 // the value for eco