AM200, first test

This commit is contained in:
MichaelDvP
2022-07-18 17:20:05 +02:00
parent 8101fcf95d
commit c765a274b2
5 changed files with 79 additions and 2 deletions

View File

@@ -26,6 +26,26 @@ uuid::log::Logger Boiler::logger_{F_(boiler), uuid::log::Facility::CONSOLE};
Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const char * version, const std::string & name, uint8_t flags, uint8_t brand)
: EMSdevice(device_type, device_id, product_id, version, name, flags, brand) {
// alternative heatsource special messages
if (device_id == EMSdevice::EMS_DEVICE_ID_AM200) {
register_telegram_type(0x54D, F("AmTemperatures"), false, MAKE_PF_CB(process_amTempMessage));
register_telegram_type(0x54E, F("AmStatus"), false, MAKE_PF_CB(process_amStatusMessage));
register_telegram_type(0x550, F("AmSettings"), false, MAKE_PF_CB(process_amSettingMessage));
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &curFlowTemp_, DeviceValueType::SHORT, FL_(div10), FL_(curFlowTemp), DeviceValueUOM::DEGREES);
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &retTemp_, DeviceValueType::SHORT, FL_(div10), FL_(retTemp), DeviceValueUOM::DEGREES);
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &aFlowTemp_, DeviceValueType::SHORT, FL_(div10), FL_(aFlowTemp), DeviceValueUOM::DEGREES);
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &aRetTemp_, DeviceValueType::SHORT, FL_(div10), FL_(aRetTemp), DeviceValueUOM::DEGREES);
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &cylTopTemp_, DeviceValueType::SHORT, FL_(div10), FL_(aCylTopTemp), DeviceValueUOM::DEGREES);
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &cylCenterTemp_, DeviceValueType::SHORT, FL_(div10), FL_(aCylCenterTemp), DeviceValueUOM::DEGREES);
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &cylBottomTemp_, DeviceValueType::SHORT, FL_(div10), FL_(aCylBottomTemp), DeviceValueUOM::DEGREES);
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &valveByPass_, DeviceValueType::BOOL, nullptr, FL_(valveByPass), DeviceValueUOM::NONE);
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &valveBuffer_, DeviceValueType::BOOL, nullptr, FL_(valveBuffer), DeviceValueUOM::NONE);
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &valveReturn_, DeviceValueType::BOOL, nullptr, FL_(valveReturn), DeviceValueUOM::NONE);
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &aPump_, DeviceValueType::BOOL, nullptr, FL_(aPump), DeviceValueUOM::NONE);
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &heatSource_, DeviceValueType::BOOL, nullptr, FL_(heatSource), DeviceValueUOM::NONE);
return;
}
// cascaded heatingsources, only some values per individual heatsource (hs)
if (device_id != EMSdevice::EMS_DEVICE_ID_BOILER) {
uint8_t hs = device_id - EMSdevice::EMS_DEVICE_ID_BOILER_1; // heating source id, count from 0
@@ -424,7 +444,7 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
DeviceValueUOM::DEGREES_R,
MAKE_CF_CB(set_ww_flowTempOffset),
0,
40);
45);
register_device_value(DeviceValueTAG::TAG_BOILER_DATA_WW,
&wwChargeOptimization_,
DeviceValueType::BOOL,
@@ -1130,6 +1150,31 @@ void Boiler::process_UBAMaintenanceData(std::shared_ptr<const Telegram> telegram
has_update(maintenanceDate_, date, sizeof(maintenanceDate_));
}
}
/*
* alternative heatingsource AM200
*/
void Boiler::process_amTempMessage(std::shared_ptr<const Telegram> telegram) {
has_update(telegram, aRetTemp_, 0);
has_update(telegram, aFlowTemp_, 6);
has_update(telegram, curFlowTemp_, 8);
has_update(telegram, retTemp_, 2);
has_update(telegram, cylTopTemp_, 10);
has_update(telegram, cylCenterTemp_, 12);
has_update(telegram, cylBottomTemp_, 14);
}
void Boiler::process_amStatusMessage(std::shared_ptr<const Telegram> telegram) {
has_update(telegram, aPump_, 0);
has_update(telegram, valveByPass_, 1);
has_update(telegram, valveBuffer_, 2);
has_update(telegram, valveReturn_, 3);
}
void Boiler::process_amSettingMessage(std::shared_ptr<const Telegram> telegram) {
// has_update(telegram, setRetTemp_, 0);
// has_update(telegram, setFlowTemp_, 1);
}
/*
* Hybrid heatpump with telegram 0xBB is readable and writeable in boiler and thermostat
* thermostat always overwrites settings in boiler