mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-07 00:09:51 +03:00
minor changes to mixing
This commit is contained in:
34
src/ems.cpp
34
src/ems.cpp
@@ -121,15 +121,19 @@ void ems_init() {
|
||||
|
||||
EMS_MixingModule.device_id = EMS_ID_NONE;
|
||||
// init all mixing modules
|
||||
for (uint8_t i = 0; i < EMS_THERMOSTAT_MAXHC; i++) {
|
||||
for (uint8_t i = 0; i < EMS_MIXING_MAXHC; i++) {
|
||||
EMS_MixingModule.hc[i].hc = i + 1;
|
||||
EMS_MixingModule.hc[i].active = false;
|
||||
EMS_MixingModule.hc[i].flowTemp = EMS_VALUE_USHORT_NOTSET;
|
||||
EMS_MixingModule.hc[i].pumpMod = EMS_VALUE_INT_NOTSET;
|
||||
EMS_MixingModule.hc[i].valveStatus = EMS_VALUE_INT_NOTSET;
|
||||
EMS_MixingModule.hc[i].flowSetTemp = EMS_VALUE_INT_NOTSET;
|
||||
}
|
||||
for (uint8_t i = 0; i < EMS_THERMOSTAT_MAXWWC; i++) {
|
||||
|
||||
// init ww circuits
|
||||
for (uint8_t i = 0; i < EMS_MIXING_MAXWWC; i++) {
|
||||
EMS_MixingModule.wwc[i].wwc = i + 1;
|
||||
EMS_MixingModule.wwc[i].active = false;
|
||||
EMS_MixingModule.wwc[i].flowTemp = EMS_VALUE_USHORT_NOTSET;
|
||||
EMS_MixingModule.wwc[i].pumpMod = EMS_VALUE_INT_NOTSET;
|
||||
EMS_MixingModule.wwc[i].tempStatus = EMS_VALUE_INT_NOTSET;
|
||||
@@ -1086,9 +1090,12 @@ void _process_UBAMonitorFast(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.wWHeat, 7, 6);
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.wWCirc, 7, 7);
|
||||
|
||||
// there may also be a BoilTemp in this telgram for Bosch - see https://github.com/proddy/EMS-ESP/issues/206
|
||||
// there may also be a BoilTemp in this telegram for Bosch - see https://github.com/proddy/EMS-ESP/issues/206
|
||||
// as well as the one from UBAMonitorSlow
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.boilTemp, 11); // 0x8000 if not available
|
||||
// brand is 0=unknown, 1=bosch, 2=junkers, 3=buderus, 4=nefit, 5=sieger, 11=worcester
|
||||
if ((EMS_Boiler.brand == 1) || (EMS_Boiler.brand == 2) || (EMS_Boiler.brand == 11)) {
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.boilTemp, 11); // 0x8000 if not available
|
||||
}
|
||||
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.retTemp, 13);
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.flameCurr, 15);
|
||||
@@ -1281,10 +1288,10 @@ void _process_EasyStatusMessage(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
_setValue(EMS_RxTelegram, &EMS_Thermostat.hc[hc].setpoint_roomTemp, EMS_OFFSET_EasyStatusMessage_setpoint); // is * 100
|
||||
}
|
||||
|
||||
// Mixer - 0x01D7, 0x01D8
|
||||
// Mixing module - 0x01D7, 0x01D8
|
||||
void _process_MMPLUSStatusMessage(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
uint8_t hc = (EMS_RxTelegram->type - EMS_TYPE_MMPLUSStatusMessage_HC1); // 0 to 3
|
||||
if (hc >= EMS_THERMOSTAT_MAXHC) {
|
||||
if (hc >= EMS_MIXING_MAXHC) {
|
||||
return; // invalid type
|
||||
}
|
||||
EMS_MixingModule.hc[hc].active = true;
|
||||
@@ -1293,11 +1300,11 @@ void _process_MMPLUSStatusMessage(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
_setValue(EMS_RxTelegram, &EMS_MixingModule.hc[hc].pumpMod, EMS_OFFSET_MMPLUSStatusMessage_pump_mod);
|
||||
_setValue(EMS_RxTelegram, &EMS_MixingModule.hc[hc].valveStatus, EMS_OFFSET_MMPLUSStatusMessage_valve_status);
|
||||
}
|
||||
// Mixer warm water loading - 0x0231, 0x0232
|
||||
|
||||
// Mixing module warm water loading - 0x0231, 0x0232
|
||||
void _process_MMPLUSStatusMessageWW(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
uint8_t wwc = (EMS_RxTelegram->type - EMS_TYPE_MMPLUSStatusMessage_WWC1); // 0 to 3
|
||||
if (wwc >= EMS_THERMOSTAT_MAXWWC) {
|
||||
uint8_t wwc = (EMS_RxTelegram->type - EMS_TYPE_MMPLUSStatusMessage_WWC1); // 0 to 1
|
||||
if (wwc >= EMS_MIXING_MAXWWC) {
|
||||
return; // invalid type
|
||||
}
|
||||
EMS_MixingModule.wwc[wwc].active = true;
|
||||
@@ -1831,6 +1838,10 @@ void _process_Version(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
EMS_Boiler.product_id = product_id;
|
||||
EMS_Boiler.device_desc_p = EMS_Devices[i].device_desc;
|
||||
strlcpy(EMS_Boiler.version, version, sizeof(EMS_Boiler.version));
|
||||
|
||||
// set brand of boiler
|
||||
EMS_Boiler.brand = brand;
|
||||
|
||||
_addDevice(EMS_DEVICE_TYPE_BOILER, product_id, EMS_ID_BOILER, EMS_Devices[i].device_desc, version, brand);
|
||||
ems_getBoilerValues(); // get Boiler values that we would usually have to wait for
|
||||
return; // quit
|
||||
@@ -2937,7 +2948,10 @@ const _EMS_Type EMS_Types[] = {
|
||||
{EMS_DEVICE_UPDATE_FLAG_MIXING, EMS_TYPE_MMPLUSStatusMessage_HC4, "MMPLUSStatusMessage_HC4", _process_MMPLUSStatusMessage},
|
||||
{EMS_DEVICE_UPDATE_FLAG_MIXING, EMS_TYPE_MMPLUSStatusMessage_WWC1, "MMPLUSStatusMessage_WWC1", _process_MMPLUSStatusMessageWW},
|
||||
{EMS_DEVICE_UPDATE_FLAG_MIXING, EMS_TYPE_MMPLUSStatusMessage_WWC2, "MMPLUSStatusMessage_WWC2", _process_MMPLUSStatusMessageWW},
|
||||
{EMS_DEVICE_UPDATE_FLAG_MIXING, EMS_TYPE_MMStatusMessage, "MMStatusMessage", _process_MMStatusMessage}};
|
||||
{EMS_DEVICE_UPDATE_FLAG_MIXING, EMS_TYPE_MMStatusMessage, "MMStatusMessage", _process_MMStatusMessage}
|
||||
|
||||
|
||||
};
|
||||
|
||||
// calculate sizes of arrays at compile time
|
||||
uint8_t _EMS_Types_max = ArraySize(EMS_Types);
|
||||
|
||||
Reference in New Issue