Merge pull request #585 from MichaelDvP/dev

AM200, EM10 changes
This commit is contained in:
Proddy
2022-07-23 14:55:29 +02:00
committed by GitHub
11 changed files with 124 additions and 24 deletions

View File

@@ -42,11 +42,12 @@
{173, DeviceType::BOILER, F("Geo 5xx"), DeviceFlags::EMS_DEVICE_FLAG_HEATPUMP},
{195, DeviceType::BOILER, F("Condens 5000i/Greenstar 8000"), DeviceFlags::EMS_DEVICE_FLAG_NONE},
{203, DeviceType::BOILER, F("Logamax U122/Cerapur"), DeviceFlags::EMS_DEVICE_FLAG_NONE},
{206, DeviceType::BOILER, F("Ecomline Excellent"), DeviceFlags::EMS_DEVICE_FLAG_NONE},
{208, DeviceType::BOILER, F("Logamax Plus/GB192/Condens GC9000"), DeviceFlags::EMS_DEVICE_FLAG_NONE},
{210, DeviceType::BOILER, F("Cascade MC400"), DeviceFlags::EMS_DEVICE_FLAG_NONE},
{211, DeviceType::BOILER, F("EasyControl Adapter"), DeviceFlags::EMS_DEVICE_FLAG_NONE},
{228, DeviceType::BOILER, F("Alternative Heatsource"), DeviceFlags::EMS_DEVICE_FLAG_AM200},
{234, DeviceType::BOILER, F("Logamax Plus GB122/Condense 2300"), DeviceFlags::EMS_DEVICE_FLAG_NONE},
{206, DeviceType::BOILER, F("Ecomline Excellent"), DeviceFlags::EMS_DEVICE_FLAG_NONE},
// Controllers - 0x09 / 0x10 / 0x50
{ 68, DeviceType::CONTROLLER, F("BC10/RFM20"), DeviceFlags::EMS_DEVICE_FLAG_NONE}, // 0x09
@@ -145,6 +146,9 @@
// Switches - 0x11
{ 71, DeviceType::SWITCH, F("WM10"), DeviceFlags::EMS_DEVICE_FLAG_NONE},
// EM10 error contact and analog flowtemp control- 0x12
{ 74, DeviceType::GATEWAY, F("Error Module EM10"), DeviceFlags::EMS_DEVICE_FLAG_NONE},
// Gateways - 0x48
{189, DeviceType::GATEWAY, F("KM200/MB LAN 2"), DeviceFlags::EMS_DEVICE_FLAG_NONE},

View File

@@ -26,6 +26,26 @@ uuid::log::Logger Boiler::logger_{F_(boiler), uuid::log::Facility::CONSOLE};
Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const char * version, const std::string & name, uint8_t flags, uint8_t brand)
: EMSdevice(device_type, device_id, product_id, version, name, flags, brand) {
// alternative heatsource special messages
if (device_id == EMSdevice::EMS_DEVICE_ID_AM200) {
register_telegram_type(0x54D, F("AmTemperatures"), false, MAKE_PF_CB(process_amTempMessage));
register_telegram_type(0x54E, F("AmStatus"), false, MAKE_PF_CB(process_amStatusMessage));
register_telegram_type(0x550, F("AmSettings"), false, MAKE_PF_CB(process_amSettingMessage));
register_device_value(DeviceValueTAG::TAG_AHS, &curFlowTemp_, DeviceValueType::SHORT, FL_(div10), FL_(sysFlowTemp), DeviceValueUOM::DEGREES);
register_device_value(DeviceValueTAG::TAG_AHS, &retTemp_, DeviceValueType::SHORT, FL_(div10), FL_(sysRetTemp), DeviceValueUOM::DEGREES);
register_device_value(DeviceValueTAG::TAG_AHS, &aFlowTemp_, DeviceValueType::SHORT, FL_(div10), FL_(aFlowTemp), DeviceValueUOM::DEGREES);
register_device_value(DeviceValueTAG::TAG_AHS, &aRetTemp_, DeviceValueType::SHORT, FL_(div10), FL_(aRetTemp), DeviceValueUOM::DEGREES);
register_device_value(DeviceValueTAG::TAG_AHS, &cylTopTemp_, DeviceValueType::SHORT, FL_(div10), FL_(aCylTopTemp), DeviceValueUOM::DEGREES);
register_device_value(DeviceValueTAG::TAG_AHS, &cylCenterTemp_, DeviceValueType::SHORT, FL_(div10), FL_(aCylCenterTemp), DeviceValueUOM::DEGREES);
register_device_value(DeviceValueTAG::TAG_AHS, &cylBottomTemp_, DeviceValueType::SHORT, FL_(div10), FL_(aCylBottomTemp), DeviceValueUOM::DEGREES);
register_device_value(DeviceValueTAG::TAG_AHS, &valveByPass_, DeviceValueType::BOOL, nullptr, FL_(valveByPass), DeviceValueUOM::NONE);
register_device_value(DeviceValueTAG::TAG_AHS, &valveBuffer_, DeviceValueType::BOOL, nullptr, FL_(valveBuffer), DeviceValueUOM::NONE);
register_device_value(DeviceValueTAG::TAG_AHS, &valveReturn_, DeviceValueType::BOOL, nullptr, FL_(valveReturn), DeviceValueUOM::NONE);
register_device_value(DeviceValueTAG::TAG_AHS, &aPump_, DeviceValueType::UINT, nullptr, FL_(aPump), DeviceValueUOM::PERCENT);
register_device_value(DeviceValueTAG::TAG_AHS, &heatSource_, DeviceValueType::BOOL, nullptr, FL_(heatSource), DeviceValueUOM::NONE);
return;
}
// cascaded heatingsources, only some values per individual heatsource (hs)
if (device_id != EMSdevice::EMS_DEVICE_ID_BOILER) {
uint8_t hs = device_id - EMSdevice::EMS_DEVICE_ID_BOILER_1; // heating source id, count from 0
@@ -424,7 +444,7 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
DeviceValueUOM::DEGREES_R,
MAKE_CF_CB(set_ww_flowTempOffset),
0,
40);
45);
register_device_value(DeviceValueTAG::TAG_BOILER_DATA_WW,
&wwChargeOptimization_,
DeviceValueType::BOOL,
@@ -655,7 +675,7 @@ void Boiler::process_UBAParameterWW(std::shared_ptr<const Telegram> telegram) {
has_bitupdate(telegram, wwChargeType_, 10, 0); // 0 = charge pump, 0xff = 3-way valve
uint8_t wwComfort = EMS_VALUE_UINT_NOTSET;
telegram->read_value(wwComfort, 9);
if (telegram->read_value(wwComfort, 9)) {
if (wwComfort == 0) {
wwComfort = 0; // Hot
} else if (wwComfort == 0xD8) {
@@ -667,6 +687,7 @@ void Boiler::process_UBAParameterWW(std::shared_ptr<const Telegram> telegram) {
}
has_update(wwComfort_, wwComfort);
}
}
/*
* UBAMonitorWW - type 0x34 - dhw monitor. 19 bytes long
@@ -827,7 +848,7 @@ void Boiler::process_UBAParameterWWPlus(std::shared_ptr<const Telegram> telegram
has_update(telegram, wwChargeOptimization_, 25);
uint8_t wwComfort1 = EMS_VALUE_UINT_NOTSET;
telegram->read_value(wwComfort1, 13);
if (telegram->read_value(wwComfort1, 13)) {
if (wwComfort1 == 0) {
wwComfort1 = 0; // High_Comfort
} else if (wwComfort1 == 0xD8) {
@@ -837,6 +858,7 @@ void Boiler::process_UBAParameterWWPlus(std::shared_ptr<const Telegram> telegram
}
has_update(wwComfort1_, wwComfort1);
}
}
// 0xE9 - WW monitor ems+
// e.g. 08 00 E9 00 37 01 F6 01 ED 00 00 00 00 41 3C 00 00 00 00 00 00 00 00 00 00 00 00 37 00 00 00 (CRC=77) #data=27
@@ -1130,6 +1152,41 @@ void Boiler::process_UBAMaintenanceData(std::shared_ptr<const Telegram> telegram
has_update(maintenanceDate_, date, sizeof(maintenanceDate_));
}
}
/*
* alternative heatingsource AM200
*/
// 0x054D AM200 temperatures
// Rx: 60 00 FF 00 04 4D 0103 0108 8000 00C6 0127 0205 8000 0200 0000 8000 6C
// TB4 TR2 TA1 TR1 TB1 TB2* TB3
void Boiler::process_amTempMessage(std::shared_ptr<const Telegram> telegram) {
has_update(telegram, curFlowTemp_, 0); // TB4
has_update(telegram, retTemp_, 2); // TR2
has_update(telegram, aFlowTemp_, 6);
has_update(telegram, aRetTemp_, 8);
has_update(telegram, cylTopTemp_, 10);
has_update(telegram, cylCenterTemp_, 12);
has_update(telegram, cylBottomTemp_, 14);
}
// 0x054E AM200 status (6 bytes long)
// Rx: 60 00 FF 00 04 4E 00 00 00 00 00 00 86
void Boiler::process_amStatusMessage(std::shared_ptr<const Telegram> telegram) {
has_update(telegram, aPump_, 0);
// actually we dont know the offset of the valves
// has_update(telegram, valveByPass_, 1);
// has_update(telegram, valveBuffer_, 2);
// has_update(telegram, valveReturn_, 3);
}
// 0x0550 AM200 broadcasted message, all 27 bytes unkown
// Rx: 60 00 FF 00 04 50 00 FF 00 FF FF 00 0D 00 01 00 00 00 00 01 03 01 00 03 00 2D 19 C8 02 94 00 4A
// Rx: 60 00 FF 19 04 50 00 FF FF 39
void Boiler::process_amSettingMessage(std::shared_ptr<const Telegram> telegram) {
// has_update(telegram, setRetTemp_, ?);
// has_update(telegram, setFlowTemp_, ?);
}
/*
* Hybrid heatpump with telegram 0xBB is readable and writeable in boiler and thermostat
* thermostat always overwrites settings in boiler

View File

@@ -198,6 +198,20 @@ class Boiler : public EMSdevice {
// Pool unit
int8_t poolSetTemp_;
// Alternative Heatsource AM200
int16_t cylTopTemp_; // TB1
int16_t cylCenterTemp_; // TB2
int16_t cylBottomTemp_; // TB3
int16_t aFlowTemp_; // TA1
int16_t aRetTemp_; // TR1
uint8_t aPump_; // PR1 - percent
uint8_t valveByPass_; // VR2
uint8_t valveBuffer_; // VB1
uint8_t valveReturn_; // VR1
uint8_t heatSource_; // OEV
// int8_t setRetTemp_;
/*
* Hybrid heatpump with telegram 0xBB is readable and writeable in boiler and thermostat
* thermostat always overwrites settings in boiler
@@ -242,6 +256,9 @@ class Boiler : public EMSdevice {
void process_HpOutdoor(std::shared_ptr<const Telegram> telegram);
void process_HpPool(std::shared_ptr<const Telegram> telegram);
void process_HybridHp(std::shared_ptr<const Telegram> telegram);
void process_amTempMessage(std::shared_ptr<const Telegram> telegram);
void process_amStatusMessage(std::shared_ptr<const Telegram> telegram);
void process_amSettingMessage(std::shared_ptr<const Telegram> telegram);
// commands - none of these use the additional id parameter
bool set_ww_mode(const char * value, const int8_t id);

View File

@@ -24,6 +24,7 @@ REGISTER_FACTORY(Switch, EMSdevice::DeviceType::SWITCH);
Switch::Switch(uint8_t device_type, uint8_t device_id, uint8_t product_id, const char * version, const std::string & name, uint8_t flags, uint8_t brand)
: EMSdevice(device_type, device_id, product_id, version, name, flags, brand) {
// WM10 module, device_id 0x11
register_telegram_type(0x9C, F("WM10MonitorMessage"), false, MAKE_PF_CB(process_WM10MonitorMessage));
register_telegram_type(0x9D, F("WM10SetMessage"), false, MAKE_PF_CB(process_WM10SetMessage));
register_telegram_type(0x1E, F("WM10TempMessage"), false, MAKE_PF_CB(process_WM10TempMessage));

View File

@@ -911,7 +911,7 @@ bool EMSdevice::get_value_info(JsonObject & output, const char * cmd, const int8
int8_t tag = id;
// check if we have hc or wwc or hs
if (id >= 1 && id <= 34) {
if (id >= 1 && id <= (1 + DeviceValueTAG::TAG_HS16 - DeviceValueTAG::TAG_HC1)) {
tag = DeviceValueTAG::TAG_HC1 + id - 1;
}

View File

@@ -309,6 +309,7 @@ class EMSdevice {
static constexpr uint8_t EMS_DEVICE_ID_BOILER = 0x08; // fixed device_id for Master Boiler/UBA
static constexpr uint8_t EMS_DEVICE_ID_BOILER_1 = 0x70; // fixed device_id for 1st. Cascade Boiler/UBA
static constexpr uint8_t EMS_DEVICE_ID_BOILER_F = 0x7F; // fixed device_id for last Cascade Boiler/UBA
static constexpr uint8_t EMS_DEVICE_ID_AM200 = 0x60; // fixed device_id for alternative Heating AM200
// generic type IDs
static constexpr uint16_t EMS_TYPE_VERSION = 0x02; // type ID for Version information. Generic across all EMS devices.
@@ -326,6 +327,7 @@ class EMSdevice {
static constexpr uint8_t EMS_DEVICE_FLAG_HT3 = 3;
static constexpr uint8_t EMS_DEVICE_FLAG_HEATPUMP = 4;
static constexpr uint8_t EMS_DEVICE_FLAG_HYBRID = 5;
static constexpr uint8_t EMS_DEVICE_FLAG_AM200 = 6;
// Solar Module
static constexpr uint8_t EMS_DEVICE_FLAG_SM10 = 1;

View File

@@ -76,6 +76,7 @@ const __FlashStringHelper * const DeviceValue::DeviceValueTAG_s[] PROGMEM = {
F_(tag_wwc8), // "wwc8"
F_(tag_wwc9), // "wwc9"
F_(tag_wwc10), // "wwc10"
F_(tag_ahs), // "ahs"
F_(tag_hs1), // "hs1"
F_(tag_hs2), // "hs2"
F_(tag_hs3), // "hs3"
@@ -121,6 +122,7 @@ const __FlashStringHelper * const DeviceValue::DeviceValueTAG_mqtt[] PROGMEM = {
F_(tag_wwc8), // "wwc8"
F_(tag_wwc9), // "wwc9"
F_(tag_wwc10), // "wwc10"
F_(tag_ahs), // "ahs"
F_(tag_hs1), // "hs1"
F_(tag_hs2), // "hs2"
F_(tag_hs3), // "hs3"

View File

@@ -96,6 +96,7 @@ class DeviceValue {
TAG_WWC8,
TAG_WWC9,
TAG_WWC10,
TAG_AHS,
TAG_HS1,
TAG_HS2,
TAG_HS3,

View File

@@ -955,9 +955,9 @@ bool EMSESP::add_device(const uint8_t device_id, const uint8_t product_id, const
for (auto & device : device_library_) {
if (device.product_id == product_id) {
// sometimes boilers share the same productID as controllers
// so only add boilers if the device_id is 0x08, which is fixed for EMS
// so only add boilers if the device_id is 0x08 or 0x60 or 0x70.., which is fixed for EMS
if (device.device_type == DeviceType::BOILER) {
if (device_id == EMSdevice::EMS_DEVICE_ID_BOILER
if (device_id == EMSdevice::EMS_DEVICE_ID_BOILER || device_id == EMSdevice::EMS_DEVICE_ID_AM200
|| (device_id >= EMSdevice::EMS_DEVICE_ID_BOILER_1 && device_id <= EMSdevice::EMS_DEVICE_ID_BOILER_F)) {
device_p = &device;
break;
@@ -1100,7 +1100,7 @@ bool EMSESP::command_commands(uint8_t device_type, JsonObject & output, const in
bool EMSESP::command_info(uint8_t device_type, JsonObject & output, const int8_t id, const uint8_t output_target) {
bool has_value = false;
uint8_t tag;
if (id >= 1 && id <= 34) {
if (id >= 1 && id <= (1 + DeviceValueTAG::TAG_HS16 - DeviceValueTAG::TAG_HC1)) {
tag = DeviceValueTAG::TAG_HC1 + id - 1; // this sets also WWC and HS
} else if (id == -1 || id == 0) {
tag = DeviceValueTAG::TAG_NONE;

View File

@@ -224,6 +224,7 @@ MAKE_PSTR(tag_wwc7, "wwc7")
MAKE_PSTR(tag_wwc8, "wwc8")
MAKE_PSTR(tag_wwc9, "wwc9")
MAKE_PSTR(tag_wwc10, "wwc10")
MAKE_PSTR(tag_ahs, "ahs")
MAKE_PSTR(tag_hs1, "hs1")
MAKE_PSTR(tag_hs2, "hs2")
MAKE_PSTR(tag_hs3, "hs3")
@@ -536,6 +537,20 @@ MAKE_PSTR_LIST(electricFactor, F("electricfactor"), F("electric energy factor"))
MAKE_PSTR_LIST(delayBoiler, F("delayboiler"), F("delay boiler support"))
MAKE_PSTR_LIST(tempDiffBoiler, F("tempdiffboiler"), F("tempediff boiler support"))
// alternative heatsource AM200
MAKE_PSTR_LIST(aCylTopTemp, F("cyltoptemp"), F("cylinder top temperature"))
MAKE_PSTR_LIST(aCylCenterTemp, F("cylcentertemp"), F("cylinder center temperature"))
MAKE_PSTR_LIST(aCylBottomTemp, F("cylbottomtemp"), F("cylinder bottom temperature"))
MAKE_PSTR_LIST(aFlowTemp, F("altflowtemp"), F("alternative hs flow temperature"))
MAKE_PSTR_LIST(aRetTemp, F("altrettemp"), F("alternative hs return temperature"))
MAKE_PSTR_LIST(sysFlowTemp, F("sysflowtemp"), F("system flow temperature"))
MAKE_PSTR_LIST(sysRetTemp, F("sysrettemp"), F("system return temperature"))
MAKE_PSTR_LIST(valveByPass, F("valvebypass"), F("bypass valve"))
MAKE_PSTR_LIST(valveBuffer, F("valvebuffer"), F("buffer valve"))
MAKE_PSTR_LIST(valveReturn, F("valvereturn"), F("return valve"))
MAKE_PSTR_LIST(aPump, F("altpump"), F("alternative hs pump"))
MAKE_PSTR_LIST(heatSource, F("heatsource"), F("alternative heating active"))
// the following are dhw for the boiler and automatically tagged with 'ww'
MAKE_PSTR_LIST(wwSelTemp, F("wwseltemp"), F("selected temperature"))
MAKE_PSTR_LIST(wwSelTempLow, F("wwseltemplow"), F("selected lower temperature"))

View File

@@ -274,6 +274,7 @@ void WebSettingsService::onUpdate() {
void WebSettingsService::begin() {
_fsPersistence.readFromFS();
WebSettings::reset_flags();
}
void WebSettingsService::save() {