@@ -31,7 +31,7 @@
|
||||
#define PUBLISHVALUES_TIME 120 // every 2 minutes post MQTT values
|
||||
Ticker publishValuesTimer;
|
||||
|
||||
#define SYSTEMCHECK_TIME 10 // every 10 seconds check if Boiler is online and execute other requests
|
||||
#define SYSTEMCHECK_TIME 20 // every 20 seconds check if Boiler is online
|
||||
Ticker systemCheckTimer;
|
||||
|
||||
#define REGULARUPDATES_TIME 60 // every minute a call is made to fetch data from EMS devices manually
|
||||
@@ -252,7 +252,7 @@ void _renderBoolValue(const char * prefix, uint8_t value) {
|
||||
void showInfo() {
|
||||
// General stats from EMS bus
|
||||
|
||||
myDebug("%sEMS-ESP System setstats:%s", COLOR_BOLD_ON, COLOR_BOLD_OFF);
|
||||
myDebug("%sEMS-ESP System stats:%s", COLOR_BOLD_ON, COLOR_BOLD_OFF);
|
||||
_EMS_SYS_LOGGING sysLog = ems_getLogging();
|
||||
if (sysLog == EMS_SYS_LOGGING_BASIC) {
|
||||
myDebug(" System logging set to Basic");
|
||||
@@ -266,8 +266,6 @@ void showInfo() {
|
||||
|
||||
myDebug(" LED is %s", EMSESP_Status.led_enabled ? "on" : "off");
|
||||
|
||||
myDebug(" # EMS type handlers: %d", ems_getEmsTypesCount());
|
||||
|
||||
myDebug(" Thermostat is %s, Boiler is %s, Poll is %s, Tx is %s, Shower Timer is %s, Shower Alert is %s",
|
||||
(ems_getThermostatEnabled() ? "enabled" : "disabled"),
|
||||
(ems_getBoilerEnabled() ? "enabled" : "disabled"),
|
||||
@@ -276,7 +274,9 @@ void showInfo() {
|
||||
((EMSESP_Status.shower_timer) ? "enabled" : "disabled"),
|
||||
((EMSESP_Status.shower_alert) ? "enabled" : "disabled"));
|
||||
|
||||
myDebug(" EMS Bus Stats: Connected=%s, # Rx telegrams=%d, # Tx telegrams=%d, # Crc Errors=%d",
|
||||
myDebug("\n%sEMS Bus Stats:%s", COLOR_BOLD_ON, COLOR_BOLD_OFF);
|
||||
myDebug(" Bus Connected=%s, Tx Capable=%s, # Rx telegrams=%d, # Tx telegrams=%d, # Crc Errors=%d",
|
||||
(ems_getTxCapable() ? "yes" : "no"),
|
||||
(ems_getBusConnected() ? "yes" : "no"),
|
||||
EMS_Sys_Status.emsRxPgks,
|
||||
EMS_Sys_Status.emsTxPkgs,
|
||||
@@ -288,7 +288,7 @@ void showInfo() {
|
||||
|
||||
// version details
|
||||
char buffer_type[64];
|
||||
myDebug(" Boiler type: %s", ems_getBoilerType(buffer_type));
|
||||
myDebug(" Boiler type: %s", ems_getBoilerDescription(buffer_type));
|
||||
|
||||
// active stats
|
||||
myDebug(" Hot tap water is %s", (EMS_Boiler.tapwaterActive ? "running" : "off"));
|
||||
@@ -357,7 +357,7 @@ void showInfo() {
|
||||
// Thermostat stats
|
||||
if (ems_getThermostatEnabled()) {
|
||||
myDebug("%sThermostat stats:%s", COLOR_BOLD_ON, COLOR_BOLD_OFF);
|
||||
myDebug(" Thermostat type: %s", ems_getThermostatType(buffer_type));
|
||||
myDebug(" Thermostat type: %s", ems_getThermostatDescription(buffer_type));
|
||||
_renderFloatValue("Setpoint room temperature", "C", EMS_Thermostat.setpoint_roomTemp);
|
||||
_renderFloatValue("Current room temperature", "C", EMS_Thermostat.curr_roomTemp);
|
||||
if (ems_getThermostatModel() != EMS_MODEL_EASY) {
|
||||
@@ -448,7 +448,7 @@ void publishValues(bool force) {
|
||||
// see if the heating or hot tap water has changed, if so send
|
||||
// last_boilerActive stores heating in bit 1 and tap water in bit 2
|
||||
if ((last_boilerActive != ((EMS_Boiler.tapwaterActive << 1) + EMS_Boiler.heatingActive)) || force) {
|
||||
myDebugLog("Publishing hot water and heating state via MQTT");
|
||||
myDebugLog("Publishing hot water and heating states via MQTT");
|
||||
myESP.mqttPublish(TOPIC_BOILER_TAPWATER_ACTIVE, EMS_Boiler.tapwaterActive == 1 ? "1" : "0");
|
||||
myESP.mqttPublish(TOPIC_BOILER_HEATING_ACTIVE, EMS_Boiler.heatingActive == 1 ? "1" : "0");
|
||||
|
||||
@@ -570,17 +570,18 @@ void FSCallback(MYESP_FSACTION action, JsonObject & json) {
|
||||
// callback for custom settings
|
||||
// wc is number of arguments after the 'set' command
|
||||
bool SettingsCallback(MYESP_FSACTION action, uint8_t wc, const char * setting, const char * value) {
|
||||
bool ok = false;
|
||||
|
||||
if (action == MYESP_FSACTION_SET) {
|
||||
if ((strcmp(setting, "led") == 0) && (wc == 2)) {
|
||||
if (strcmp(value, "on") == 0) {
|
||||
EMSESP_Status.led_enabled = true;
|
||||
ok = true;
|
||||
} else if (strcmp(value, "off") == 0) {
|
||||
EMSESP_Status.led_enabled = false;
|
||||
ok = true;
|
||||
// let's make sure LED is really off
|
||||
digitalWrite(BOILER_LED, (BOILER_LED == LED_BUILTIN) ? HIGH : LOW); // light off. For onboard high=off
|
||||
} else {
|
||||
// unknown command
|
||||
return false;
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -589,7 +590,7 @@ bool SettingsCallback(MYESP_FSACTION action, uint8_t wc, const char * setting, c
|
||||
myDebug(" led=%s", EMSESP_Status.led_enabled ? "on" : "off");
|
||||
}
|
||||
|
||||
return true;
|
||||
return ok;
|
||||
}
|
||||
|
||||
// call back when a telnet client connects or disconnects
|
||||
@@ -762,7 +763,7 @@ void MQTTCallback(unsigned int type, const char * topic, const char * message) {
|
||||
// handle incoming MQTT publish events
|
||||
if (type == MQTT_MESSAGE_EVENT) {
|
||||
// handle response from a start message
|
||||
// for HA, it gets sent the bootime
|
||||
// for example with HA it sends the system time from the server
|
||||
if (strcmp(topic, MQTT_TOPIC_START) == 0) {
|
||||
myDebug("Received boottime: %s", message);
|
||||
myESP.setBoottime(message);
|
||||
@@ -828,9 +829,10 @@ void WIFICallback() {
|
||||
myDebug("[UART] Opened Rx/Tx connection");
|
||||
#endif
|
||||
|
||||
// now that we're connected, check to see if we boiler and thermostat set
|
||||
// otherwise this will initiate a self scan
|
||||
ems_setModels();
|
||||
// now that we're connected, set up the boiler and thermostat
|
||||
// the boiler's version will be requested and if there is no thermostat hardcoded it will try
|
||||
// and find the first one
|
||||
ems_discoverModels();
|
||||
}
|
||||
|
||||
// Initialize the boiler settings and shower settings
|
||||
@@ -879,20 +881,16 @@ void do_scanThermostat() {
|
||||
// do a system health check every now and then to see if we all connections
|
||||
void do_systemCheck() {
|
||||
if (!ems_getBusConnected()) {
|
||||
myDebug("Error! Unable to connect to EMS bus. Check connection and make sure you're not in DEBUG_SUPPORT mode. Retrying in %d "
|
||||
"seconds...",
|
||||
SYSTEMCHECK_TIME);
|
||||
myDebug("Error! Unable to read from EMS bus. Retrying in %d seconds...", SYSTEMCHECK_TIME);
|
||||
}
|
||||
}
|
||||
|
||||
// force calls to get data from EMS for the types that aren't sent as broadcasts
|
||||
// only if we have a EMS connection
|
||||
void do_regularUpdates() {
|
||||
if (ems_getBusConnected()) {
|
||||
myDebugLog("Calling scheduled data refresh from EMS devices..");
|
||||
ems_getThermostatValues();
|
||||
ems_getBoilerValues();
|
||||
}
|
||||
myDebugLog("Calling scheduled data refresh from EMS devices..");
|
||||
ems_getThermostatValues();
|
||||
ems_getBoilerValues();
|
||||
}
|
||||
|
||||
// turn off hot water to send a shot of cold
|
||||
@@ -1010,7 +1008,7 @@ void setup() {
|
||||
|
||||
// init the EMS bus
|
||||
// call ems.cpp's init function to set all the internal params
|
||||
ems_init(MY_BOILER_MODELID, MY_THERMOSTAT_MODELID);
|
||||
ems_init(MY_THERMOSTAT_MODELID);
|
||||
}
|
||||
|
||||
//
|
||||
|
||||